Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2024-0656+Manufacturer_Specifications_and_Installation_Instructions+5.14.2024_2.27.09_PM+4256544
BLD2024-0656 RECEIVED May 15 2024 DZ4SEA COMMERCIAL REVIEWED BY CITY OF EDMONDS " DAIKIN COOLING CAPACITY.36,000 TO 60,000 BTUIH HEATING CAPACITY.' 36,000 TO 60,000 BTUIH 1 ■ Standard Features • R-410A chlorine -free refrigerant • Energy -efficient scroll compressor • Low-pressure switch • Liquid refrigerant return protection • Factory -installed, bi-flow liquid -line filter drier • Service valves with sweat connec- tions and easy -access gauge ports • Copper tube/enhanced aluminum fin coil • Reliable time -initiated, temperature - terminated defrost control • Contactor with lug connection • Ground lug connection • Units meet the performance outlined in Table 6.8.1B of ASHRAE Standard 90.1-2010 • AHRI Certified; ETL Listed • Match systems have a minimum SEER2 rating of 14.3 3, 4, & 5-TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14.3 SEER2/R-410A A Contents Nomenclature .............................. 2 Product Specifications .................3 Expanded Cooling Data................4 Expanded Heating Data .............16 AHRI Ratings..............................17 Dimensions................................18 Wiring Diagram ..........................19 Accessories................................20 ■ Cabinet Features • Innovative sound control top design • Steel louver coil guard • Heavy -gauge galvanized -steel cabinet • Attractive Nickel Gray powder -paint finish • Top and side maintenance access • Service ports and controls are accessible while unit is operating • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) iM C us ®� �a L-M 9001 1 ♦ ���C1ENTIFIED Intertek m,. *Complete warranty details available from your local dealer or at www.daikincomfort.com. SS-DZ4SEA www.daikinac.com 04/23 NOMENCLATURE D z 4 S E A 36 3 0 A A 1 2 Brand D - Daikin Type X-AC Z-HP SEER2 14.3 S - Single Stage Feature E - Base Sales Region A - All Region 3 4 5 6 7,8 9 10 11 12 Minor revision A: Intial Release B: 1st Revision Major revision A: Intial Release B: 1st Revision Variations Electrical 3 - 208/230 V Three -Phase 60 Hz 4 - 460 V Three -Phase 60 Hz Nominal Capacity 36 - 3 Tons 48-4Tons 60-5Tons 2 www.daikinac.com SS-DZ4SEA SPECIFICATIONS 6030 .0 COOLING CAPACITIES NOMINAL COOLING (BTU/H)' 36,000 36,000 48,000 48,000 60,000 60,000 Nominal Heating (BTU/h)' 36,000 36,000 48,000 48,000 60,000 60,000 Decibels (dB) 74 74 75 75 76 76 COMPRESSOR RLA 10.9 5.4 14 6.4 15.4 7.1 LRA 98 43 120.4 55.1 155 62 CONDENSER FAN MOTOR Horsepower 1/6 1/6 1/4 1/4 1/4 1/4 FLA 0.97 0.60 1.3 0.80 1.3 0.80 REFRIGERATION SYSTEM Liquid Connection Valve Size (O.D.) 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction Connection Valve Size (C.D.) 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge (oz.)Z 114 114 222 222 269 269 ELECTRICAL DATA AC Volts 200/230 460 200/230 460 200/230 460 Hz / Phase 60Hz/ 3 60Hz/ 3 60Hz/ 3 60Hz/ 3 60Hz/ 3 60Hz/ 3 Minimum Circuit Ampacity3 14.5 7.4 18.0 8.7 20.4 9.5 Max. Overcurrent Protection4 25 15 30 15 35 15 Min / Max Volts 197/253 414/506 197/253 414/506 197/253 414/506 Electrical Conduit Size %" or %" %" or %" I %" or %" %" or %" %" or %" %" or %" SHIP WEIGHT (LBS) 233 236 292 295 321 321 ' Tested and rated in accordance with ARI Standard ' Factory Holding Charge. Follow Instructions for system charge 3 Wire size should be determined in accordance with National Electrical Codes; extensive wireruns will require larger wire sizes ° Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15' of %" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. SS-DZ4SEA www.daikinac.com OUTDOOR AMBIENT TEMPERATURE 65 75 7 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.1 35.6 36.7 - 34.8 35.3 36.4 - 33.9 34.4 35.4 - 32.3 32.8 33.9 - 30.4 30.9 31.9 - 28.7 29.1 30.2 - S/T 0.60 0.53 0.40 0.61 0.54 0.41 0.63 0.56 0.43 0.65 0.58 0.45 0.67 0.60 0.47 1.00 0.65 0.52 AT 18 17 13 18 17 13 18 17 14 18 16 13 18 16 13 19 17 14 1050 kW 2.07 2.07 2.06 2.32 2.31 2.31 2.59 2.59 2.58 2.89 2.88 2.88 3.22 3.22 3.21 3.61 3.61 3.60 Amps 7.8 7.7 7.7 8.9 8.9 8.8 10.1 10.1 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 Hi PR 247 248 250 286 287 289 326 327 329 370 371 373 417 419 420 468 469 471 Lo PR 119 120 123 126 128 131 132 134 137 138 139 142 143 144 147 149 151 154 MBh 35.5 36.0 37.0 35.1 35.6 36.7 34.2 34.7 35.8 32.7 33.2 34.2 30.7 31.2 32.3 29.0 29.5 30.5 S/T 0.64 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 0.69 0.62 0.49 1.00 0.64 0.51 1.00 0.69 0.56 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 70 1150 kW 2.08 2.08 2.07 2.32 2.32 2.32 2.60 2.60 2.59 2.90 2.89 2.89 3.23 3.23 3.22 3.62 3.61 3.61 Amps 7.8 7.8 7.8 8.9 8.9 8.9 10.2 10.2 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 HiPR 248 249 251 287 288 290 328 329 331 372 373 374 419 420 422 469 470 472 Lo PR 120 122 125 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 36.3 36.7 37.8 35.9 36.4 37.5 35.0 35.5 36.6 33.5 34.0 35.0 31.5 32.0 33.1 29.8 30.3 31.3 S/T 0.68 0.61 0.48 0.69 0.61 0.48 0.71 0.64 0.51 0.73 0.66 0.52 1.00 0.68 0.55 1.00 0.73 0.60 AT 16 15 11 16 15 11 17 15 12 16 15 11 16 14 11 17 15 12 1350 kW 2.09 2.09 2.09 2.34 2.34 2.33 2.61 2.61 2.61 2.91 2.91 2.90 3.24 3.24 3.24 3.63 3.63 3.62 Amps 7.9 7.8 7.8 9.0 9.0 9.0 10.2 10.2 10.2 11.6 11.6 11.6 13.1 13.1 13.1 14.9 14.9 14.9 HiPR 251 252 254 290 291 293 331 332 333 375 376 377 422 423 425 472 473 475 Lo PR 123 124 127 130 131 134 136 138 141 142 143 146 147 148 151 153 155 158 MBh 35.1 35.6 36.7 38.3 34.8 35.3 36.4 38.0 33.9 34.4 35.5 37.1 32.4 32.8 33.9 35.5 30.4 30.9 32.0 33.6 28.7 29.2 30.2 31.8 S/T 0.73 0.65 0.52 0.39 0.73 0.66 0.53 0.39 0.76 0.68 0.55 0.42 1.00 0.70 0.57 0.44 1.00 0.72 0.59 0.46 1.00 0.77 0.64 0.51 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 14 23 21 18 15 1050 kW 2.07 2.07 2.06 2.08 2.31 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.21 3.21 3.23 3.61 3.60 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 Hi PR 247 248 250 254 286 287 289 293 327 328 329 334 370 372 373 378 418 419 420 425 468 469 471 475 Lo PR 119 120 123 128 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 151 154 159 MBh 35.5 36.0 37.0 38.6 35.2 35.7 36.7 38.3 34.3 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.3 32.3 33.9 29.0 29.5 30.5 32.1 S/T 0.76 0.69 0.56 0.42 0.77 0.70 0.57 0.43 1.00 0.72 0.59 0.45 1.00 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.81 0.68 0.54 AT 21 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 20 17 14 75 1150 kW 2.08 2.07 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.59 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.61 3.61 3.61 3.63 Amps 7.8 7.8 7.8 7.8 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 251 256 287 288 290 294 328 329 331 335 372 373 375 379 419 420 422 426 470 471 472 477 Lo PR 120 122 125 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 36.3 36.8 37.8 39.4 36.0 36.5 37.5 39.1 35.0 35.5 36.6 38.2 33.5 34.0 35.0 36.6 31.6 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 0.80 0.73 0.60 0.46 0.81 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 1.00 0.72 0.58 AT 20 18 15 12 20 18 15 12 20 19 15 12 20 18 15 12 20 18 15 12 21 19 16 13 1350 kW 2.09 2.09 2.09 2.10 2.34 2.33 2.33 2.35 2.61 2.61 2.61 2.62 2.91 2.91 2.90 2.92 3.24 3.24 3.23 3.25 3.63 3.63 3.62 3.64 Amps 7.8 7.8 7.8 7.9 9.0 9.0 8.9 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.6 13.1 13.1 13.1 13.2 14.9 14.9 14.9 14.9 HiPR 251 252 254 258 290 291 293 297 331 332 334 338 375 376 378 382 422 423 425 429 472 473 475 479 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 148 151 156 153 155 158 163 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q OUTDOOR AMBIENT TEMPERATURE 65 F 75 7 85 1 95 105 115 D: ENTERING INDOOR WET BULB TEMPERATURE MBh 35.3 35.8 36.9 38.5 35.0 35.5 36.6 38.2 34.1 34.6 35.6 37.2 32.5 33.0 34.1 35.7 30.6 31.1 32.1 33.7 28.9 29.4 30.4 - 32.5 S/T 0.85 0.77 0.64 0.51 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.54 1.00 0.82 0.69 0.56 1.00 0.84 0.71 0.58 1.00 1.00 0.76 0.63 AT 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1050 kW 2.07 2.07 2.06 2.08 2.32 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.22 3.21 3.23 3.61 3.61 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 Hi PR 248 249 250 255 286 287 289 293 327 328 330 334 371 372 374 378 418 419 421 425 469 470 471 476 Lo PR 119 121 124 129 127 128 131 136 133 134 137 142 138 140 143 148 143 145 148 153 150 151 154 160 MBh 35.7 36.2 37.2 38.8 35.3 35.8 36.9 38.5 34.4 34.9 36.0 37.6 32.9 33.4 34.4 36.0 30.9 31.4 32.5 34.1 29.2 29.7 30.7 32.3 S/T 0.89 0.81 0.68 0.54 1.00 0.82 0.69 0.55 1.00 0.84 0.71 0.57 1.00 0.86 0.73 0.59 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 25 23 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 17 26 24 21 18 80 1150 kW 2.08 2.08 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.60 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.62 3.61 3.61 3.63 Amps 7.8 7.8 7.8 7.8 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 252 256 288 289 291 295 329 330 331 336 372 373 375 379 420 421 422 427 470 471 473 477 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 36.5 37.0 38.0 39.6 36.1 36.6 37.7 39.3 35.2 35.7 36.8 38.4 33.7 34.2 35.2 36.8 31.7 32.2 33.3 34.9 30.0 30.5 31.5 33.1 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 15 25 23 20 17 1350 kW 2.09 2.09 2.09 2.11 2.34 2.34 2.33 2.35 2.61 2.61 2.61 2.63 2.91 2.91 2.90 2.92 3.24 3.24 3.24 3.25 3.63 3.63 3.62 3.64 Amps 7.9 7.8 7.8 7.9 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 252 253 255 259 291 292 293 298 331 332 334 338 375 376 378 382 422 423 425 430 473 474 476 480 Lo PR 1 123 125 128 133 1 131 132 135 140 1 137 138 141 146 1 142 144 147 152 1 147 149 152 157 1 154 155 158 164 MBh 35.9 36.4 37.5 39.1 35.6 36.1 37.1 38.7 34.7 35.2 36.2 37.8 33.1 33.6 34.7 36.3 31.2 31.7 32.7 34.3 29.4 29.9 31.0 32.6 S/T 1.00 0.87 0.74 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.86 0.7 AT 29 28 24 21 29 27 24 21 29 28 25 21 29 27 24 21 29 27 24 21 30 28 25 22 1050 kW 2.07 2.07 2.07 2.1 2.32 2.32 2.31 2.3 2.59 2.59 2.59 2.6 2.89 2.89 2.88 2.9 3.22 3.22 3.22 3.2 3.61 3.61 3.61 3.6 Amps 7.8 7.8 7.7 7.8 8.9 8.9 8.9 9.0 10.2 10.1 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 251 256 288 289 290 295 328 329 331 335 372 373 375 379 419 420 422 426 470 471 473 477 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 144 150 145 147 150 155 152 153 156 161 MBh 36.2 36.7 37.8 39.4 35.9 36.4 37.5 39.1 35.0 35.5 36.6 38.2 33.4 33.9 35.0 36.6 31.5 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 1.00 0.91 0.78 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 20 28 27 24 20 28 27 23 20 29 28 24 21 85 1150 kW 2.08 2.08 2.08 2.1 2.33 2.33 2.32 2.3 2.60 2.60 2.60 2.6 2.90 2.90 2.89 2.9 3.23 3.23 3.23 3.2 3.62 3.62 3.61 3.6 Amps 7.8 7.8 7.8 7.9 8.9 8.9 8.9 9.0 10.2 10.2 10.2 10.2 11.6 11.5 11.5 11.6 13.1 13.1 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 250 251 253 257 289 290 292 296 330 331 332 337 373 375 376 381 421 422 424 428 471 472 474 478 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 154 157 163 MBh 37.0 37.5 38.6 40.2 36.7 37.2 38.3 39.9 35.8 36.3 37.4 39.0 34.2 34.7 35.8 37.4 32.3 32.8 33.9 35.5 30.6 31.1 32.1 33.7 S/T 1.00 0.95 0.82 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.8 1.00 1.00 1.00 0.8 AT 27 26 22 19 27 26 22 19 28 26 23 19 27 26 22 19 27 25 22 19 28 26 23 20 1350 kW 2.10 2.10 2.09 2.1 2.34 2.34 2.34 2.4 2.62 2.62 2.61 2.6 2.91 2.91 2.91 2.9 3.25 3.24 3.24 3.3 3.64 3.63 3.63 3.6 Amps 7.9 7.9 7.8 7.9 9.0 9.0 9.0 9.1 10.3 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 253 254 256 260 292 293 295 299 333 334 335 340 376 377 379 383 424 425 426 431 474 475 477 481 Lo PR 125 127 130 135 132 134 137 142 139 140 143 148 144 145 148 154 149 151 154 159 156 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 35.1 35.6 36.7 - 34.8 35.3 36.4 - 33.9 34.4 35.4 - 32.3 32.8 33.9 - 30.4 30.9 31.9 - 28.7 29.1 30.2 - S/T 0.60 0.53 0.40 0.61 0.54 0.41 0.63 0.56 0.43 0.65 0.58 0.45 0.67 0.60 0.47 1.00 0.65 0.52 AT 18 17 13 18 17 13 18 17 14 18 16 13 18 16 13 19 17 14 1050 kW 2.07 2.07 2.06 2.32 2.31 2.31 2.59 2.59 2.58 2.89 2.88 2.88 3.22 3.22 3.21 3.61 3.61 3.60 Amps 7.8 7.7 7.7 8.9 8.9 8.8 10.1 10.1 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 HiPR 247 248 250 286 287 289 326 327 329 370 371 373 417 419 420 468 469 471 Lo PR 119 120 123 126 128 131 132 134 137 138 139 142 143 144 147 149 151 154 MBh 35.5 36.0 37.0 35.1 35.6 36.7 34.2 34.7 35.8 32.7 33.2 34.2 30.7 31.2 32.3 29.0 29.5 30.5 S/T 0.64 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 0.69 0.62 0.49 1.00 0.64 0.51 1.00 0.69 0.56 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 70 1150 kW 2.08 2.08 2.07 2.32 2.32 2.32 2.60 2.60 2.59 2.90 2.89 2.89 3.23 3.23 3.22 3.62 3.61 3.61 Amps 7.8 7.8 7.8 8.9 8.9 8.9 10.2 10.2 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 HiPR 248 249 251 287 288 290 328 329 331 372 373 374 419 420 422 469 470 472 Lo PR 120 122 125 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 36.3 36.7 37.8 35.9 36.4 37.5 35.0 35.5 36.6 33.5 34.0 35.0 31.5 32.0 33.1 29.8 30.3 31.3 S/T 0.68 0.61 0.48 0.69 0.61 0.48 0.71 0.64 0.51 0.73 0.66 0.52 1.00 0.68 0.55 1.00 0.73 0.60 AT 16 15 11 16 15 11 17 15 12 16 15 11 16 14 11 17 15 12 1350 kW 2.09 2.09 2.09 2.34 2.34 2.33 2.61 2.61 2.61 2.91 2.91 2.90 3.24 3.24 3.24 3.63 3.63 3.62 Amps 7.9 7.8 7.8 9.0 9.0 9.0 10.2 10.2 10.2 11.6 11.6 11.6 13.1 13.1 13.1 14.9 14.9 14.9 HiPR 251 252 254 290 291 293 331 332 333 375 376 377 422 423 425 472 473 475 Lo PR 123 124 127 130 131 134 136 138 141 142 143 146 147 148 151 153 155 158 MBh 35.1 35.6 36.7 38.3 34.8 35.3 36.4 38.0 33.9 34.4 35.5 37.1 32.4 32.8 33.9 35.5 30.4 30.9 32.0 33.6 28.7 29.2 30.2 31.8 S/T 0.73 0.65 0.52 0.39 0.73 0.66 0.53 0.39 0.76 0.68 0.55 0.42 1.00 0.70 0.57 0.44 1.00 0.72 0.59 0.46 1.00 0.77 0.64 0.51 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 14 23 21 18 15 1050 kW 2.07 2.07 2.06 2.08 2.31 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.21 3.21 3.23 3.61 3.60 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 Hi PR 247 248 250 254 286 287 289 293 327 328 329 334 370 372 373 378 418 419 420 425 468 469 471 475 Lo PR 119 120 123 128 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 151 154 159 MBh 35.5 36.0 37.0 38.6 35.2 35.7 36.7 38.3 34.3 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.3 32.3 33.9 29.0 29.5 30.5 32.1 S/T 0.76 0.69 0.56 0.42 0.77 0.70 0.57 0.43 1.00 0.72 0.59 0.45 1.00 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.81 0.68 0.54 AT 21 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 20 17 14 75 1150 kW 2.08 2.07 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.59 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.61 3.61 3.61 3.63 Amps 7.8 7.8 7.8 7.8 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 HiPR 249 250 251 256 287 288 290 294 328 329 331 335 372 373 375 379 419 420 422 426 470 471 472 477 Lo PR 120 122 125 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 36.3 36.8 37.8 39.4 36.0 36.5 37.5 39.1 35.0 35.5 36.6 38.2 33.5 34.0 35.0 36.6 31.6 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 0.80 0.73 0.60 0.46 0.81 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 1.00 0.72 0.58 AT 20 18 15 12 20 18 15 12 20 19 15 12 20 18 15 12 20 18 15 12 21 19 16 13 1350 kW 2.09 2.09 2.09 2.10 2.34 2.33 2.33 2.35 2.61 2.61 2.61 2.62 2.91 2.91 2.90 2.92 3.24 3.24 3.23 3.25 3.63 3.63 3.62 3.64 Amps 7.8 7.8 7.8 7.9 9.0 9.0 8.9 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.6 13.1 13.1 13.1 13.2 14.9 14.9 14.9 14.9 HiPR 251 252 254 258 290 291 293 297 331 332 334 338 375 376 378 382 422 423 425 429 472 473 475 479 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 148 151 156 153 155 158 163 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 35.3 35.8 36.9 38.5 35.0 35.5 36.6 38.2 34.1 34.6 35.6 37.2 32.5 33.0 34.1 35.7 30.6 31.1 32.1 33.7 28.9 29.4 30.4 32.0 S/T 0.85 0.77 0.64 0.51 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.54 1.00 0.82 0.69 0.56 1.00 0.84 0.71 0.58 1.00 1.00 0.76 0.63 AT 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1050 kW 2.07 2.07 2.06 2.08 2.32 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.22 3.21 3.23 3.61 3.61 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 Hi PR 248 249 250 255 286 287 289 293 327 328 330 334 371 372 374 378 418 419 421 425 469 470 471 476 Lo PR 119 121 124 129 127 128 131 136 133 134 137 142 138 140 143 148 143 145 148 153 150 151 154 160 MBh 35.7 36.2 37.2 38.8 35.3 35.8 36.9 38.5 34.4 34.9 36.0 37.6 32.9 33.4 34.4 36.0 30.9 31.4 32.5 34.1 29.2 29.7 30.7 32.3 S/T 0.89 0.81 0.68 0.54 1.00 0.82 0.69 0.55 1.00 0.84 0.71 0.57 1.00 0.86 0.73 0.59 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 25 23 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 17 26 24 21 18 80 1150 kW 2.08 2.08 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.60 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.62 3.61 3.61 3.63 Amps 78 78 78 78 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 252 256 288 289 291 295 329 330 331 336 372 373 375 379 420 421 422 427 470 471 473 477 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 36.5 37.0 38.0 39.6 36.1 36.6 37.7 39.3 35.2 35.7 36.8 38.4 33.7 34.2 35.2 36.8 31.7 32.2 33.3 34.9 30.0 30.5 31.5 33.1 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 15 25 23 20 17 1350 kW 2.09 2.09 2.09 2.11 2.34 2.34 2.33 2.35 2.61 2.61 2.61 2.63 2.91 2.91 2.90 2.92 3.24 3.24 3.24 3.25 3.63 3.63 3.62 3.64 Amps 7.9 7.8 7.8 7.9 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 252 253 255 259 291 292 293 298 331 332 334 338 375 376 378 382 422 423 425 430 473 474 476 480 Lo PR 123 125 128 133 131 132 135 140 137 138 141 146 142 144 147 152 147 149 152 157 154 155 158 164 MBh 35.9 36.4 37.5 39.1 35.6 36.1 37.1 38.7 34.7 35.2 36.2 37.8 33.1 33.6 34.7 36.3 31.2 31.7 32.7 34.3 29.4 29.9 31.0 32.6 S/T 1.00 0.87 0.74 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.86 0.7 AT 29 28 24 21 29 27 24 21 29 28 25 21 29 27 24 21 29 27 24 21 30 28 25 22 1050 kW 2.07 2.07 2.07 2.1 2.32 2.32 2.31 2.3 2.59 2.59 2.59 2.6 2.89 2.89 2.88 2.9 3.22 3.22 3.22 3.2 3.61 3.61 3.61 3.6 Amps 78 78 77 78 8.9 8.9 8.9 9.0 10.2 10.1 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 251 256 288 289 290 295 328 329 331 335 372 373 375 379 419 420 422 426 470 471 473 477 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 144 150 145 147 150 155 152 153 156 161 MBh 36.2 36.7 37.8 39.4 35.9 36.4 37.5 39.1 35.0 35.5 36.6 38.2 33.4 33.9 35.0 36.6 31.5 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 1.00 0.91 0.78 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 20 28 27 24 20 28 27 23 20 29 28 24 21 85 1150 kW 2.08 2.08 2.08 2.1 2.33 2.33 2.32 2.3 2.60 2.60 2.60 2.6 2.90 2.90 2.89 2.9 3.23 3.23 3.23 3.2 3.62 3.62 3.61 3.6 Amps 7.8 7.8 7.8 7.9 8.9 8.9 8.9 9.0 10.2 10.2 10.2 10.2 11.6 11.5 11.5 11.6 13.1 13.1 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 250 251 253 257 289 290 292 296 330 331 332 337 373 375 376 381 421 422 424 428 471 472 474 478 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 154 157 163 MBh 37.0 37.5 38.6 40.2 36.7 37.2 38.3 39.9 35.8 36.3 37.4 39.0 34.2 34.7 35.8 37.4 32.3 32.8 33.9 35.5 30.6 31.1 32.1 33.7 S/T 1.00 0.95 0.82 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.8 1.00 1.00 1.00 0.8 AT 27 26 22 19 27 26 22 19 28 26 23 19 27 26 22 19 27 25 22 19 28 26 23 20 1350 kW 2.10 2.10 2.09 2.1 2.34 2.34 2.34 2.4 2.62 2.62 2.61 2.6 2.91 2.91 2.91 2.9 3.25 3.24 3.24 3.3 3.64 3.63 3.63 3.6 Amps 7.9 7.9 7.8 7.9 9.0 9.0 9.0 9.1 10.3 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 253 254 256 260 292 293 295 299 333 334 335 340 376 377 379 383 424 425 426 431 474 475 477 481 Lo PR 125 127 130 135 132 134 137 142 139 140 143 148 144 145 148 154 149 151 154 159 156 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) x Zj n QD Uj P4 W n C N O r O z y OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 46.7 47.3 48.7 - 46.3 46.9 48.3 - 45.1 45.7 47.1 - 43.0 43.6 45.0 - 40.4 41.1 42.5 - 38.1 38.8 40.2 - S/T 0.63 0.56 0.43 0.64 0.56 0.43 0.66 0.59 0.46 0.68 0.61 0.48 1.00 0.63 0.50 1.00 0.68 0.55 AT 19 17 14 19 17 13 19 17 14 19 17 13 18 17 13 19 18 14 1400 kW 2.73 2.73 2.73 3.06 3.06 3.05 3.43 3.43 3.42 3.82 3.82 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.3 17.3 17.3 19.7 19.7 19.7 HiPR 243 244 246 282 283 284 322 323 324 365 366 367 411 412 414 461 462 463 Lo PR 120 121 124 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 46.9 47.6 48.9 46.5 47.1 48.5 45.3 45.9 47.3 43.2 43.9 45.2 40.7 41.3 42.7 38.3 39.0 40.4 S/1- 0.65 0.57 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.62 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 18 17 13 18 16 13 19 17 13 18 16 13 18 16 13 19 17 14 70 1460 kW 2.74 2.74 2.73 3.07 3.06 3.06 3.43 3.43 3.43 3.83 3.83 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.4 17.4 17.3 19.7 19.7 19.7 HiPR 244 245 247 282 283 285 322 323 325 365 366 368 412 413 414 461 462 464 Lo PR 121 122 125 128 129 132 134 136 139 139 141 144 145 146 149 151 153 156 MBh 47.4 48.1 49.5 47.0 47.7 49.1 45.8 46.5 47.9 43.7 44.4 45.8 41.2 41.9 43.2 38.9 39.5 40.9 S/T 0.68 0.60 0.47 0.68 0.61 0.48 0.71 0.63 0.50 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 12 18 16 12 18 16 13 18 16 12 17 15 12 18 17 13 1600 kW 2.75 2.75 2.74 3.08 3.08 3.07 3.44 3.44 3.44 3.84 3.84 3.83 4.28 4.28 4.28 4.80 4.80 4.80 Amps 10.4 10.4 10.4 11.9 11.9 11.9 13.6 13.6 13.5 15.4 15.4 15.4 17.4 17.4 17.4 19.8 19.8 19.8 HiPR 246 247 248 284 285 286 324 325 326 367 368 370 413 414 416 463 464 466 Lo PR 122 123 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 46.7 47.4 48.8 50.9 46.3 47.0 48.3 50.4 45.1 45.7 47.1 49.2 43.0 43.7 45.0 47.2 40.5 41.1 42.5 44.6 38.1 38.8 40.2 42.3 S/T 0.76 0.68 0.55 0.41 0.76 0.69 0.56 0.42 1.00 0.72 0.58 0.44 1.00 0.73 0.60 0.46 1.00 0.76 0.62 0.48 1.00 0.81 0.67 0.53 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 22 20 17 14 23 22 18 15 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.42 3.42 3.44 3.82 3.82 3.81 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 244 245 246 251 282 283 284 289 322 323 324 329 365 366 368 372 411 412 414 418 461 462 464 468 Lo PR 120 121 124 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5 S/T 0.77 0.70 0.57 0.43 0.78 0.71 0.57 0.44 1.00 0.73 0.60 0.46 1.00 0.75 0.62 0.48 1.00 0.77 0.64 0.50 1.00 0.82 0.69 0.55 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 1460 kW 2.74 2.73 2.73 2.75 3.06 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.84 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.3 17.3 17.4 19.7 19.7 19.7 19.8 HiPR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 415 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.5 48.1 49.5 51.6 47.1 47.7 49.1 51.2 45.9 46.5 47.9 50.0 43.8 44.4 45.8 47.9 41.2 41.9 43.3 45.4 38.9 39.6 40.9 43.1 S/T 0.80 0.73 0.60 0.46 0.81 0.73 0.60 0.46 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 0.85 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1600 kW 2.75 2.74 2.74 2.76 3.08 3.07 3.07 3.09 3.44 3.44 3.43 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.27 4.30 4.80 4.80 4.79 4.82 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.6 15.4 15.4 15.3 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 HiPR 246 247 248 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 151 146 148 151 156 153 154 157 162 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q ,31 • • OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 47.0 47.6 49.0 51.1 46.5 47.2 48.6 50.7 45.3 46.0 47.4 49.5 43.3 43.9 45.3 47.4 40.7 41.4 42.7 44.9 38.4 39.0 40.4 42.5 S/T 0.88 0.81 0.67 0.54 1.00 0.81 0.68 0.54 1.00 0.84 0.71 0.57 1.00 0.86 0.72 0.58 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 27 25 21 18 27 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 26 22 19 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.43 3.42 3.44 3.82 3.82 3.82 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 45.1 38.6 39.3 40.6 42.8 S/T 0.90 0.82 0.69 0.55 1.00 0.83 0.70 0.56 1.00 0.85 0.72 0.58 1.00 0.87 0.74 0.60 1.00 1.00 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 80 1460 kW 2.74 2.74 2.73 2.76 3.07 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.85 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 245 246 247 252 283 284 286 290 323 324 326 330 366 367 369 373 412 413 415 419 462 463 465 469 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 145 150 145 147 150 155 152 153 156 161 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.3 51.4 46.1 46.7 48.1 50.2 44.0 44.7 46.0 48.2 41.5 42.1 43.5 45.6 39.1 39.8 41.2 43.3 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.72 0.58 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 26 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 25 21 18 1600 kW 2.75 2.75 2.74 2.77 3.08 3.07 3.07 3.09 3.44 3.44 3.44 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.28 4.30 4.80 4.80 4.80 4.82 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 463 464 466 470 Lo PR 123 124 127 132 130 131 134 139 136 138 141 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.4 51.5 46.1 46.8 48.1 50.3 44.0 44.7 46.1 48.2 41.5 42.1 43.5 45.6 39.2 39.8 41.2 43.3 S/T 1.00 0.91 0.77 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 1400 kW 2.74 2.74 2.73 2.8 3.07 3.06 3.06 3.1 3.43 3.43 3.43 3.5 3.83 3.83 3.82 3.8 4.27 4.27 4.27 4.3 4.79 4.79 4.79 4.8 Amps 10.3 10.3 10.3 10.4 11.9 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4 19.8 19.7 19.7 19.8 Hi PR 245 246 248 252 283 284 286 290 323 324 326 330 366 367 369 373 413 414 416 420 462 463 465 469 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 155 158 163 MBh 47.9 48.6 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 45.9 39.4 40.0 41.4 43.5 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 29 28 24 21 31 29 25 22 85 1460 kW 2.74 2.74 2.74 2.8 3.07 3.07 3.06 3.1 3.44 3.44 3.43 3.5 3.84 3.83 3.83 3.9 4.28 4.28 4.27 4.3 4.80 4.80 4.79 4.8 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.8 12.0 13.6 13.5 13.5 13.6 15.4 15.4 15.3 15.4 17.4 17.4 17.4 17.5 19.8 19.8 19.7 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 415 416 420 463 464 466 470 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 163 MBh 48.5 49.1 50.5 52.6 48.1 48.7 50.1 52.2 46.9 47.5 48.9 51.0 44.8 45.4 46.8 48.9 42.2 42.9 44.3 46.4 39.9 40.6 42.0 44.1 S/T 1.00 0.95 0.82 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1600 kW 2.76 2.75 2.75 2.8 3.08 3.08 3.08 3.1 3.45 3.45 3.44 3.5 3.85 3.84 3.84 3.9 4.29 4.29 4.28 4.3 4.81 4.81 4.80 4.8 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 247 248 250 254 285 287 288 292 325 327 328 332 369 370 371 376 415 416 418 422 465 466 467 472 Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.7 47.3 48.7 - 46.3 46.9 48.3 - 45.1 45.7 47.1 - 43.0 43.6 45.0 - 40.4 41.1 42.5 - 38.1 38.8 40.2 - S/T 0.63 0.56 0.43 0.64 0.56 0.43 0.66 0.59 0.46 0.68 0.61 0.48 1.00 0.63 0.50 1.00 0.68 0.55 AT 19 17 14 19 17 13 19 17 14 19 17 13 18 17 13 19 18 14 1400 kW 2.73 2.73 2.73 3.06 3.06 3.05 3.43 3.43 3.42 3.82 3.82 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.3 17.3 17.3 19.7 19.7 19.7 HiPR 243 244 246 282 283 284 322 323 324 365 366 367 411 412 414 461 462 463 Lo PR 120 121 124 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 46.9 47.6 48.9 46.5 47.1 48.5 45.3 45.9 47.3 43.2 43.9 45.2 40.7 41.3 42.7 38.3 39.0 40.4 S/T 0.65 0.57 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.62 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 18 17 13 18 16 13 19 17 13 18 16 13 18 16 13 19 17 14 70 1460 kW 2.74 2.74 2.73 3.07 3.06 3.06 3.43 3.43 3.43 3.83 3.83 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.4 17.4 17.3 19.7 19.7 19.7 HiPR 244 245 247 282 283 285 322 323 325 365 366 368 412 413 414 461 462 464 Lo PR 121 122 125 128 129 132 134 136 139 139 141 144 145 146 149 151 153 156 MBh 47.4 48.1 49.5 47.0 47.7 49.1 45.8 46.5 47.9 43.7 44.4 45.8 41.2 41.9 43.2 38.9 39.5 40.9 S/T 0.68 0.60 0.47 0.68 0.61 0.48 0.71 0.63 0.50 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 12 18 16 12 18 16 13 18 16 12 17 15 12 18 17 13 1600 kW 2.75 2.75 2.74 3.08 3.08 3.07 3.44 3.44 3.44 3.84 3.84 3.83 4.28 4.28 4.28 4.80 4.80 4.80 Amps 10.4 10.4 10.4 11.9 11.9 11.9 13.6 13.6 13.5 15.4 15.4 15.4 17.4 17.4 17.4 19.8 19.8 19.8 HiPR 246 247 248 284 285 286 324 325 326 367 368 370 413 414 416 463 464 466 Lo PR 122 123 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 46.7 47.4 48.8 50.9 46.3 47.0 48.3 50.4 45.1 45.7 47.1 49.2 43.0 43.7 45.0 47.2 40.5 41.1 42.5 44.6 38.1 38.8 40.2 42.3 S/T 0.76 0.68 0.55 0.41 0.76 0.69 0.56 0.42 1.00 0.72 0.58 0.44 1.00 0.73 0.60 0.46 1.00 0.76 0.62 0.48 1.00 0.81 0.67 0.53 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 22 20 17 14 23 22 18 15 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.42 3.42 3.44 3.82 3.82 3.81 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 244 245 246 251 282 283 284 289 322 323 324 329 365 366 368 372 411 412 414 418 461 462 464 468 Lo PR 120 121 124 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5 S/T 0.77 0.70 0.57 0.43 0.78 0.71 0.57 0.44 1.00 0.73 0.60 0.46 1.00 0.75 0.62 0.48 1.00 0.77 0.64 0.50 1.00 0.82 0.69 0.55 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 1460 kW 2.74 2.73 2.73 2.75 3.06 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.84 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.3 17.3 17.4 19.7 19.7 19.7 19.8 HiPR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 415 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.5 48.1 49.5 51.6 47.1 47.7 49.1 51.2 45.9 46.5 47.9 50.0 43.8 44.4 45.8 47.9 41.2 41.9 43.3 45.4 38.9 39.6 40.9 43.1 S/T 0.80 0.73 0.60 0.46 0.81 0.73 0.60 0.46 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 0.85 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1600 kW 2.75 2.74 2.74 2.76 3.08 3.07 3.07 3.09 3.44 3.44 3.43 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.27 4.30 4.80 4.80 4.79 4.82 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.6 15.4 15.4 15.3 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 HiPR 246 247 248 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 151 146 148 151 156 153 154 157 162 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q OUTDOOR AMBIENT TEMPERATURE 65 75 7 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: MBh 47.0 47.6 49.0 51.1 46.5 47.2 48.6 50.7 45.3 46.0 47.4 49.5 43.3 43.9 45.3 47.4 40.7 41.4 42.7 44.9 38.4 39.0 40.4 42.5 S/T 0.88 0.81 0.67 0.54 1.00 0.81 0.68 0.54 1.00 0.84 0.71 0.57 1.00 0.86 0.72 0.58 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 27 25 21 18 27 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 26 22 19 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.43 3.42 3.44 3.82 3.82 3.82 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 45.1 38.6 39.3 40.6 42.8 S/T 0.90 0.82 0.69 0.55 1.00 0.83 0.70 0.56 1.00 0.85 0.72 0.58 1.00 0.87 0.74 0.60 1.00 1.00 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 80 1460 kW 2.74 2.74 2.73 2.76 3.07 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.85 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 245 246 247 252 283 284 286 290 323 324 326 330 366 367 369 373 412 413 415 419 462 463 465 469 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 145 150 145 147 150 155 152 153 156 161 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.3 51.4 46.1 46.7 48.1 50.2 44.0 44.7 46.0 48.2 41.5 42.1 43.5 45.6 39.1 39.8 41.2 43.3 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.72 0.58 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 26 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 25 21 18 1600 kW 2.75 2.75 2.74 2.77 3.08 3.07 3.07 3.09 3.44 3.44 3.44 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.28 4.30 4.80 4.80 4.80 4.82 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 463 464 466 470 Lo PR 123 124 127 132 130 131 134 139 136 138 141 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.4 51.5 46.1 46.8 48.1 50.3 44.0 44.7 46.1 48.2 41.5 42.1 43.5 45.6 39.2 39.8 41.2 43.3 S/T 1.00 0.91 0.77 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.89 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 1400 kW 2.74 2.74 2.73 2.8 3.07 3.06 3.06 3.1 3.43 3.43 3.43 3.5 3.83 3.83 3.82 3.8 4.27 4.27 4.27 4.3 4.79 4.79 4.79 4.8 Amps 10.3 10.3 10.3 10.4 11.9 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4 19.8 19.7 19.7 19.8 Hi PR 245 246 248 252 283 284 286 290 323 324 326 330 366 367 369 373 413 414 416 420 462 463 465 469 Lo PR 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 155 158 163 MBh 47.9 48.6 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 45.9 39.4 40.0 41.4 43.5 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 29 28 24 21 31 29 25 22 85 1460 kW 2.74 2.74 2.74 2.8 3.07 3.07 3.06 3.1 3.44 3.44 3.43 3.5 3.84 3.83 3.83 3.9 4.28 4.28 4.27 4.3 4.80 4.80 4.79 4.8 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.8 12.0 13.6 13.5 13.5 13.6 15.4 15.4 15.3 15.4 17.4 17.4 17.4 17.5 19.8 19.8 19.7 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 415 416 420 463 464 466 470 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 163 MBh 48.5 49.1 50.5 52.6 48.1 48.7 50.1 52.2 46.9 47.5 48.9 51.0 44.8 45.4 46.8 48.9 42.2 42.9 44.3 46.4 39.9 40.6 42.0 44.1 S/T 1.00 0.95 0.82 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1600 kW 2.76 2.75 2.75 2.8 3.08 3.08 3.08 3.1 3.45 3.45 3.44 3.5 3.85 3.84 3.84 3.9 4.29 4.29 4.28 4.3 4.81 4.81 4.80 4.8 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 247 248 250 254 285 287 288 292 325 327 328 332 369 370 371 376 415 416 418 422 465 466 467 472 Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 56.4 57.2 58.8 - 55.9 56.7 58.3 - 54.4 55.2 56.9 - 51.9 52.7 54.4 - 48.8 49.6 51.3 - 46.0 46.8 48.5 - S/T 0.65 0.57 0.43 0.65 0.58 0.44 0.68 0.60 0.47 0.70 0.62 0.49 0.72 0.64 0.51 1.00 0.69 0.56 AT 18 17 13 18 17 13 19 17 14 18 17 13 18 16 13 19 17 14 1750 kW 3.41 3.41 3.40 3.83 3.83 3.82 4.31 4.31 4.30 4.82 4.82 4.81 5.40 5.40 5.39 6.07 6.07 6.06 Amps 12.9 12.9 12.9 14.9 14.9 14.8 17.1 17.0 17.0 19.4 19.4 19.4 22.0 22.0 22.0 25.1 25.1 25.1 HiPR 258 259 261 298 299 301 340 342 343 386 387 389 435 436 438 488 489 491 Lo PR 116 117 120 123 124 127 129 130 133 134 135 138 139 141 143 145 147 150 MBh 56.7 57.5 59.2 56.2 57.0 58.7 54.7 55.5 57.2 52.2 53.0 54.7 49.1 49.9 51.6 46.3 47.1 48.8 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 0.72 0.64 0.51 0.74 0.66 0.53 1.00 0.71 0.58 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1840 kW 3.42 3.41 3.41 3.84 3.84 3.83 4.32 4.31 4.31 4.83 4.83 4.82 5.41 5.40 5.40 6.08 6.08 6.07 Amps 13.0 12.9 12.9 14.9 14.9 14.9 17.1 17.1 17.0 19.4 19.4 19.4 22.1 22.1 22.0 25.2 25.1 25.1 HiPR 258 260 261 299 300 302 341 342 344 387 388 390 436 437 439 489 490 492 Lo PR 116 118 121 123 125 128 130 131 134 135 136 139 140 141 144 146 148 150 MBh 57.0 57.8 59.4 56.5 57.3 58.9 55.0 55.8 57.5 52.5 53.3 55.0 49.4 50.2 51.9 46.6 47.4 49.1 S/T 0.68 0.60 0.47 0.69 0.61 0.48 0.71 0.64 0.50 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.73 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 1920 kW 3.42 3.42 3.41 3.85 3.85 3.84 4.32 4.32 4.31 4.84 4.84 4.83 5.41 5.41 5.40 6.09 6.08 6.08 Amps 13.0 13.0 12.9 14.9 14.9 14.9 17.1 17.1 17.1 19.5 19.5 19.4 22.1 22.1 22.1 25.2 25.2 25.1 HiPR 259 260 262 300 301 303 342 343 345 388 389 391 437 438 440 489 490 492 Lo PR 117 118 121 124 125 128 130 132 134 135 137 140 140 142 145 147 148 151 1750 MBh S/T AT kW Amps HiPR Lo PR 56.4 0.78 22 3.41 12.9 258 116 57.2 0.70 20 3.40 12.9 259 117 58.9 0.56 17 3.39 12.9 261 120 61.4 0.42 14 3.43 13.0 265 125 55.9 0.78 22 3.83 14.9 298 123 56.7 0.71 20 3.83 14.8 299 124 58.4 0.57 17 3.82 14.8 301 127 60.9 0.43 14 3.85 15.0 306 132 54.5 0.81 22 4.31 17.0 341 129 55.2 0.73 21 4.30 17.0 342 130 56.9 0.60 17 4.30 17.0 344 133 59.5 0.45 14 4.33 17.1 348 138 51.9 1.00 22 4.82 19.4 386 134 52.7 0.75 20 4.82 19.4 387 135 54.4 0.61 17 4.81 19.3 389 138 57.0 0.47 14 4.84 19.5 394 143 48.9 1.00 22 5.40 22.0 436 139 49.7 0.77 20 5.39 22.0 437 141 51.3 0.64 17 5.39 22.0 438 143 53.9 0.49 13 5.42 22.1 443 148 46.1 1.00 23 6.07 25.1 488 145 46.9 0.82 21 6.07 25.1 489 147 48.5 0.69 18 6.06 25.1 491 150 51.1 0.55 15 6.09 25.2 495 155 MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.8 55.6 57.2 59.8 52.2 53.0 54.7 57.3 49.2 50.0 51.6 54.2 46.4 47.2 48.8 51.4 S/T 0.80 0.72 0.58 0.44 0.80 0.73 0.59 0.45 0.83 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.84 0.71 0.57 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 1840 kW 3.41 3.41 3.40 3.44 3.84 3.84 3.83 3.86 4.31 4.31 4.30 4.34 4.83 4.83 4.82 4.85 5.40 5.40 5.39 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.0 22.0 22.2 25.1 25.1 25.1 25.2 HiPR 259 260 262 266 299 300 302 307 342 343 344 349 387 388 390 395 436 437 439 444 489 490 492 496 Lo PR 116 118 121 126 123 125 128 133 130 131 134 139 135 136 139 144 140 141 144 149 146 148 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.4 49.1 51.7 S/T 0.81 0.73 0.60 0.46 0.82 0.74 0.60 0.46 0.84 0.77 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.81 0.67 0.53 1.00 0.86 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1920 kW 3.42 3.42 3.41 3.44 3.85 3.84 3.84 3.87 4.32 4.32 4.31 4.34 4.84 4.83 4.83 4.86 5.41 5.41 5.40 5.43 6.09 6.08 6.07 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.4 19.4 19.6 22.1 22.1 22.0 22.2 25.2 25.2 25.1 25.3 HiPR 259 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 444 490 491 492 497 Lo PR 117 119 121 126 124 125 128 133 130 132 135 139 135 137 140 145 140 142 145 150 147 148 151 156 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.7 55.5 57.2 59.8 52.2 53.0 54.7 57.2 49.2 50.0 51.6 54.2 46.4 47.1 48.8 51.4 S/T 0.90 0.83 0.69 0.55 1.00 0.83 0.70 0.55 1.00 0.86 0.72 0.58 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1750 kW 3.41 3.40 3.40 3.43 3.83 3.83 3.82 3.86 4.31 4.31 4.30 4.33 4.82 4.82 4.81 4.85 5.40 5.39 5.39 5.42 6.07 6.07 6.06 6.09 Amps 12.9 12.9 12.9 13.0 14.9 14.9 14.8 15.0 17.0 17.0 17.0 17.1 19.4 19.4 19.4 19.5 22.0 22.0 22.0 22.1 25.1 25.1 25.1 25.2 Hi PR 258 259 261 266 299 300 302 306 341 342 344 349 387 388 390 394 436 437 439 443 488 490 491 496 Lo PR 116 118 121 126 123 125 128 132 129 131 134 139 135 136 139 144 140 141 144 149 146 147 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.5 49.1 51.7 S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 0.92 0.78 0.64 1.00 1.00 0.83 0.69 AT 26 24 21 17 26 24 21 17 26 24 21 18 26 24 21 17 25 24 20 17 27 25 22 18 80 1840 kW 3.42 3.41 3.41 3.44 3.84 3.84 3.83 3.86 4.32 4.31 4.31 4.34 4.83 4.83 4.82 4.85 5.41 5.40 5.40 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 259 260 262 267 300 301 303 307 342 343 345 349 388 389 391 395 437 438 440 444 489 490 492 497 Lo PR 117 118 121 126 124 125 128 133 130 131 134 139 135 137 140 144 140 142 145 150 147 148 151 156 MBh 57.3 58.1 59.8 62.3 56.8 57.6 59.3 61.8 55.3 56.1 57.8 60.4 52.8 53.6 55.3 57.8 49.8 50.5 52.2 54.8 46.9 47.7 49.4 52.0 S/T 0.94 0.86 0.72 0.58 1.00 0.87 0.73 0.59 1.00 0.89 0.76 0.61 1.00 0.91 0.77 0.63 1.00 0.93 0.80 0.65 1.00 1.00 0.85 0.71 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 1920 kW 3.42 3.42 3.41 3.44 3.85 3.85 3.84 3.87 4.32 4.32 4.31 4.35 4.84 4.84 4.83 4.86 5.41 5.41 5.40 5.44 6.09 6.08 6.08 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 25.3 Hi PR 260 261 263 267 300 301 303 308 343 344 346 350 388 389 391 396 438 439 440 445 490 491 493 497 Lo PR 118 119 122 127 125 126 129 134 131 132 135 140 136 137 140 145 141 142 145 150 147 149 152 157 MBh 57.7 58.4 60.1 62.7 57.2 57.9 59.6 62.2 55.7 56.5 58.2 60.7 53.2 54.0 55.6 58.2 50.1 50.9 52.6 55.1 47.3 48.1 49.8 52.3 S/T 1.00 0.93 0.79 0.6 1.00 0.93 0.80 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.92 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 29 28 24 21 30 29 25 22 1750 kW 3.42 3.41 3.41 3.4 3.84 3.84 3.83 3.9 4.32 4.31 4.31 4.3 4.83 4.83 4.82 4.9 5.41 5.40 5.40 5.4 6.08 6.08 6.07 6.1 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 260 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 445 490 491 493 497 Lo PR 118 119 122 127 125 126 129 134 131 133 135 140 136 138 141 146 141 143 146 151 148 149 152 157 MBh 58.0 58.7 60.4 63.0 57.5 58.2 59.9 62.5 56.0 56.8 58.5 61.0 53.5 54.3 55.9 58.5 50.4 51.2 52.9 55.4 47.6 48.4 50.1 52.6 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 0.98 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.94 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1840 kW 3.42 3.42 3.41 3.4 3.85 3.85 3.84 3.9 4.33 4.32 4.31 4.3 4.84 4.84 4.83 4.9 5.41 5.41 5.40 5.4 6.09 6.09 6.08 6.1 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 25.3 Hi PR 260 262 263 268 301 302 304 308 343 344 346 351 389 390 392 396 438 439 441 445 491 492 493 498 Lo PR 119 120 123 128 126 127 130 135 132 133 136 141 137 138 141 146 142 143 146 151 148 150 153 158 MBh 58.2 59.0 60.7 63.3 57.7 58.5 60.2 62.8 56.3 57.1 58.7 61.3 53.8 54.6 56.2 58.8 50.7 51.5 53.2 55.7 47.9 48.7 50.4 52.9 S/T 1.00 0.96 0.83 0.7 1.00 0.97 0.83 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1920 kW 3.43 3.43 3.42 3.5 3.86 3.85 3.85 3.9 4.33 4.33 4.32 4.4 4.85 4.84 4.84 4.9 5.42 5.42 5.41 5.4 6.10 6.09 6.09 6.1 Amps 13.0 13.0 13.0 13.1 15.0 15.0 14.9 15.1 17.2 17.1 17.1 17.3 19.5 19.5 19.5 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.2 25.3 Hi PR 261 262 264 269 302 303 304 309 344 345 347 351 390 391 392 397 439 440 442 446 491 492 494 499 Lo PR 119 121 124 129 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 150 153 158 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) k z 0 m 0 O 'z n OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 56.4 57.2 58.8 - 55.9 56.7 58.3 - 54.4 55.2 56.9 - 51.9 52.7 54.4 - 48.8 49.6 51.3 - 46.0 46.8 48.5 - S/T 0.65 0.57 0.43 0.65 0.58 0.44 0.68 0.60 0.47 0.70 0.62 0.49 0.72 0.64 0.51 1.00 0.69 0.56 AT 18 17 13 18 17 13 19 17 14 18 17 13 18 16 13 19 17 14 1750 kW 3.41 3.41 3.40 3.83 3.83 3.82 4.31 4.31 4.30 4.82 4.82 4.81 5.40 5.40 5.39 6.07 6.07 6.06 Amps 12.9 12.9 12.9 14.9 14.9 14.8 17.1 17.0 17.0 19.4 19.4 19.4 22.0 22.0 22.0 25.1 25.1 25.1 HiPR 258 259 261 298 299 301 340 342 343 386 387 389 435 436 438 488 489 491 Lo PR 116 117 120 123 124 127 129 130 133 134 135 138 139 141 143 145 147 150 MBh 56.7 57.5 59.2 56.2 57.0 58.7 54.7 55.5 57.2 52.2 53.0 54.7 49.1 49.9 51.6 46.3 47.1 48.8 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 0.72 0.64 0.51 0.74 0.66 0.53 1.00 0.71 0.58 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1840 kW 3.42 3.41 3.41 3.84 3.84 3.83 4.32 4.31 4.31 4.83 4.83 4.82 5.41 5.40 5.40 6.08 6.08 6.07 Amps 13.0 12.9 12.9 14.9 14.9 14.9 17.1 17.1 17.0 19.4 19.4 19.4 22.1 22.1 22.0 25.2 25.1 25.1 HiPR 258 260 261 299 300 302 341 342 344 387 388 390 436 437 439 489 490 492 Lo PR 116 118 121 123 125 128 130 131 134 135 136 139 140 141 144 146 148 150 MBh 57.0 57.8 59.4 56.5 57.3 58.9 55.0 55.8 57.5 52.5 53.3 55.0 49.4 50.2 51.9 46.6 47.4 49.1 S/T 0.68 0.60 0.47 0.69 0.61 0.48 0.71 0.64 0.50 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.73 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 1920 kW 3.42 3.42 3.41 3.85 3.85 3.84 4.32 4.32 4.31 4.84 4.84 4.83 5.41 5.41 5.40 6.09 6.08 6.08 Amps 13.0 13.0 12.9 14.9 14.9 14.9 17.1 17.1 17.1 19.5 19.5 19.4 22.1 22.1 22.1 25.2 25.2 25.1 HiPR 259 260 262 300 301 303 342 343 345 388 389 391 437 438 440 489 490 492 Lo PR 117 118 121 124 125 128 130 132 134 135 137 140 140 142 145 147 148 151 1750 MBh S/T AT kW Amps HiPR Lo PR 56.4 0.78 22 3.41 12.9 258 116 57.2 0.70 20 3.40 12.9 259 117 58.9 0.56 17 3.39 12.9 261 120 61.4 0.42 14 3.43 13.0 265 125 55.9 0.78 22 3.83 14.9 298 123 56.7 0.71 20 3.83 14.8 299 124 58.4 0.57 17 3.82 14.8 301 127 60.9 0.43 14 3.85 15.0 306 132 54.5 0.81 22 4.31 17.0 341 129 55.2 0.73 21 4.30 17.0 342 130 56.9 0.60 17 4.30 17.0 344 133 59.5 0.45 14 4.33 17.1 348 138 51.9 1.00 22 4.82 19.4 386 134 52.7 0.75 20 4.82 19.4 387 135 54.4 0.61 17 4.81 19.3 389 138 57.0 0.47 14 4.84 19.5 394 143 48.9 1.00 22 5.40 22.0 436 139 49.7 0.77 20 5.39 22.0 437 141 51.3 0.64 17 5.39 22.0 438 143 53.9 0.49 13 5.42 22.1 443 148 46.1 1.00 23 6.07 25.1 488 145 46.9 0.82 21 6.07 25.1 489 147 48.5 0.69 18 6.06 25.1 491 150 51.1 0.55 15 6.09 25.2 495 155 MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.8 55.6 57.2 59.8 52.2 53.0 54.7 57.3 49.2 50.0 51.6 54.2 46.4 47.2 48.8 51.4 S/T 0.80 0.72 0.58 0.44 0.80 0.73 0.59 0.45 0.83 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.84 0.71 0.57 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 1840 kW 3.41 3.41 3.40 3.44 3.84 3.84 3.83 3.86 4.31 4.31 4.30 4.34 4.83 4.83 4.82 4.85 5.40 5.40 5.39 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.0 22.0 22.2 25.1 25.1 25.1 25.2 HiPR 259 260 262 266 299 300 302 307 342 343 344 349 387 388 390 395 436 437 439 444 489 490 492 496 Lo PR 116 118 121 126 123 125 128 133 130 131 134 139 135 136 139 144 140 141 144 149 146 148 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.4 49.1 51.7 S/T 0.81 0.73 0.60 0.46 0.82 0.74 0.60 0.46 0.84 0.77 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.81 0.67 0.53 1.00 0.86 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1920 kW 3.42 3.42 3.41 3.44 3.85 3.84 3.84 3.87 4.32 4.32 4.31 4.34 4.84 4.83 4.83 4.86 5.41 5.41 5.40 5.43 6.09 6.08 6.07 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.4 19.4 19.6 22.1 22.1 22.0 22.2 25.2 25.2 25.1 25.3 HiPR 259 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 444 490 491 492 497 Lo PR 117 119 121 126 124 125 128 133 130 132 135 139 135 137 140 145 140 142 145 150 147 148 151 156 IDB: Entering Indoor Dry Bulb Temperature Shaded area is ACCA (TVA) conditions. KW=Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) k n Q OUTDOOR AMBIENT TEMPERATURE 65 75 85 1 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.7 55.5 57.2 59.8 52.2 53.0 54.7 57.2 49.2 50.0 51.6 54.2 46.4 47.1 48.8 51.4 S/T 0.90 0.83 0.69 0.55 1.00 0.83 0.70 0.55 1.00 0.86 0.72 0.58 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1750 kW 3.41 3.40 3.40 3.43 3.83 3.83 3.82 3.86 4.31 4.31 4.30 4.33 4.82 4.82 4.81 4.85 5.40 5.39 5.39 5.42 6.07 6.07 6.06 6.09 Amps 12.9 12.9 12.9 13.0 14.9 14.9 14.8 15.0 17.0 17.0 17.0 17.1 19.4 19.4 19.4 19.5 22.0 22.0 22.0 22.1 25.1 25.1 25.1 25.2 Hi PR 258 259 261 266 299 300 302 306 341 342 344 349 387 388 390 394 436 437 439 443 488 490 491 496 Lo PR 116 118 121 126 123 125 128 132 129 131 134 139 135 136 139 144 140 141 144 149 146 147 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.5 49.1 51.7 S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 0.92 0.78 0.64 1.00 1.00 0.83 0.69 AT 26 24 21 17 26 24 21 17 26 24 21 18 26 24 21 17 25 24 20 17 27 25 22 18 80 1840 kW 3.42 3.41 3.41 3.44 3.84 3.84 3.83 3.86 4.32 4.31 4.31 4.34 4.83 4.83 4.82 4.85 5.41 5.40 5.40 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 259 260 262 267 300 301 303 307 342 343 345 349 388 389 391 395 437 438 440 444 489 490 492 497 Lo PR 117 118 121 126 124 125 128 133 130 131 134 139 135 137 140 144 140 142 145 150 147 148 151 156 MBh 57.3 58.1 59.8 62.3 56.8 57.6 59.3 61.8 55.3 56.1 57.8 60.4 52.8 53.6 55.3 57.8 49.8 50.5 52.2 54.8 46.9 47.7 49.4 52.0 S/T 0.94 0.86 0.72 0.58 1.00 0.87 0.73 0.59 1.00 0.89 0.76 0.61 1.00 0.91 0.77 0.63 1.00 0.93 0.80 0.65 1.00 1.00 0.85 0.71 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 1920 kW 3.42 3.42 3.41 3.44 3.85 3.85 3.84 3.87 4.32 4.32 4.31 4.35 4.84 4.84 4.83 4.86 5.41 5.41 5.40 5.44 6.09 6.08 6.08 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 25.3 Hi PR 260 261 263 267 300 301 303 308 343 344 346 350 388 389 391 396 438 439 440 445 490 491 493 497 Lo PR 118 119 122 127 125 126 129 134 131 132 135 140 136 137 140 145 141 142 145 150 147 149 152 157 MBh 57.7 58.4 60.1 62.7 57.2 57.9 59.6 62.2 55.7 56.5 58.2 60.7 53.2 54.0 55.6 58.2 50.1 50.9 52.6 55.1 47.3 48.1 49.8 52.3 S/T 1.00 0.93 0.79 0.6 1.00 0.93 0.80 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.92 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 29 28 24 21 30 29 25 22 1750 kW 3.42 3.41 3.41 3.4 3.84 3.84 3.83 3.9 4.32 4.31 4.31 4.3 4.83 4.83 4.82 4.9 5.41 5.40 5.40 5.4 6.08 6.08 6.07 6.1 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 260 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 445 490 491 493 497 Lo PR 118 119 122 127 125 126 129 134 131 133 135 140 136 138 141 146 141 143 146 151 148 149 152 157 MBh 58.0 58.7 60.4 63.0 57.5 58.2 59.9 62.5 56.0 56.8 58.5 61.0 53.5 54.3 55.9 58.5 50.4 51.2 52.9 55.4 47.6 48.4 50.1 52.6 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 0.98 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.94 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1840 kW 3.42 3.42 3.41 3.4 3.85 3.85 3.84 3.9 4.33 4.32 4.31 4.3 4.84 4.84 4.83 4.9 5.41 5.41 5.40 5.4 6.09 6.09 6.08 6.1 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 25.3 Hi PR 260 262 263 268 301 302 304 308 343 344 346 351 389 390 392 396 438 439 441 445 491 492 493 498 Lo PR 119 120 123 128 126 127 130 135 132 133 136 141 137 138 141 146 142 143 146 151 148 150 153 158 MBh 58.2 59.0 60.7 63.3 57.7 58.5 60.2 62.8 56.3 57.1 58.7 61.3 53.8 54.6 56.2 58.8 50.7 51.5 53.2 55.7 47.9 48.7 50.4 52.9 S/T 1.00 0.96 0.83 0.7 1.00 0.97 0.83 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1920 kW 3.43 3.43 3.42 3.5 3.86 3.85 3.85 3.9 4.33 4.33 4.32 4.4 4.85 4.84 4.84 4.9 5.42 5.42 5.41 5.4 6.10 6.09 6.09 6.1 Amps 13.0 13.0 13.0 13.1 15.0 15.0 14.9 15.1 17.2 17.1 17.1 17.3 19.5 19.5 19.5 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.2 25.3 Hi PR 261 262 264 269 302 303 304 309 344 345 347 351 390 391 392 397 439 440 442 446 491 492 494 499 Lo PR 119 121 124 129 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 150 153 158 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area is AHRI conditions. KW=Total system power Amps = outdoor unit amps (comp.+fan) k z 0 m 0 O 'z n EXPANDED HEATING DATA DZ4SEA3630 / AMST36CU1400A OUTDOOR AMBIENT 7KW 43.80 41.10 38.60 36.00 34�� 33.20 30.30 27.50 25.20 23.50 22.30 21.60 20.70 18.60 16.50 14.30 12.20 33.9+ 32.20 30.40 28.70 27.70 26.80 24.40 22.10 20.30 18.90 17.90 17.40 16.70 15.00 13.30 11.60 9.80 3.10 3.10 3.00 2.90 2.90 2.80 2.70 2.60 2.60 2.50 2.40 2.40 2.30 2.30 2.20 2.10 11.9 11.5 11.2 10.9 10.7 10.6 10.2 9.9 9.6 9.3 9.0 8.8 8.6 8.3 8.3 7.7 7.3 COP 4.07 3.92 3.77 3.61 3.50 3.41 3.20 2.98 2.81 2.69 2.63 2.60 2.53 2.34 2.14 1.93 1.70 Hi PR 434 420 406 391 383 377 363 349 335 321 307 298 293 279 264 250 236 LO PR 1 133 124 116 108 103 100 91 83 1 75 67 58 53 1 50 42 34 25 1 17 DZ4SEA3640 / AMST36CU1400A • ...• MBh 43.80 41.10 38.60 36.00 33.20 30.30 27.50 25.20 23.50 22.30 21.60 20.70 18.60 16.50 14.30 12.20 T/R 33.9+ 32.20 30.40 28.70 27.70 26.80 24.40 22.10 20.30 18.90 17.90 17.40 16.70 15.00 13.30 11.60 9.80 KW 3.10 3.10 3.00 2.90 2.90 2.80 2.70 2.60 2.60 2.50 2.40 2.40 2.30 2.30 2.20 2.10 AMPS 11.9 11.5 11.2 10.9 10.7 10.6 10.2 9.9 9.6 9.3 9.0 8.8 8.6 8.3 8.3 7.7 7.3 COP 4.07 3.92 3.77 3.61 3.50 3.41 3.20 2.98 2.81 2.69 2.63 2.60 2.53 2.34 2.14 1.93 1.70 Hi PR 434 420 406 391 383 377 363 349 335 321 307 298 293 279 264 250 236 LO PR 133 124 116 108 103 100 91 83 75 67 58 53 50 42 34 25 17 DZ4SEA4830 / ASMT48CU1400A OUTDOOR AMBIENT MBh 59.10 55.40 51.80 48.30 46.00 44.40 40.20 36.20 33.00 30.70 28.90 28.00 26.80 23.80 20.80 17.80 14.80 T/R 36.00 34.10 32.20 30.30 29.20 2.81 25.50 23.00 20.90 19.40 18.30 17.80 17.00 15.10 13.20 11.30 9.40 KW 3.90 3.80 3.70 3.70 M 3.60 3.60 3.50 3.40 3.40 3.30 3.30 3.30 3.20 3.10 3.10 3.00 AMPS 14.5 14.2 13.9 13.7 13.5 13.4 13.2 12.9 12.6 12.4 12.1 12.0 11.9 11.6 11.3 11.1 10.8 COP 4.48 4.27 4.06 3.85 3.70 3.59 3.31 3.03 2.81 2.66 2.55 2.50 2.41 2.18 1.94 1.69 1.44 Hi PR 433 419 405 390 382 376 362 348 334 320 306 298 292 278 264 250 136 LO PR 137 128 120 111 106 103 94 86 77 69 60 55 52 43 35 16 18 DZ4SEA4840 / ASMT48CU1400A OUTDOOR AMBIENT TEMPERATURE MBh 59.10 55.40 51.80 48.30 46.0� 44.40 40.20 36.20 33.00 30.70 28.90 28.00 26.80 23.80 20.80 17.80 14.80 T/R 36.00 34.10 32.20 30.30 29.20 2.81 25.50 23.00 20.90 19.40 18.30 17.80 17.00 15.10 13.20 11.30 9.40 KW 3.90 3.80 3.70 3.70 3.60 3.60 3.50 3.40 3.40 3.30 3.30 3.30 3.20 3.10 3.10 3.00 AMPS 14.5 14.2 13.9 13.7 13.5 13.4 13.2 12.9 12.6 12.4 12.1 12.0 11.9 11.6 11.3 11.1 10.8 COP 4.48 4.27 4.06 3.85 3.70 3.59 3.31 3.03 2.81 2.66 2.55 2.50 2.41 2.18 1.94 1.69 1.44 Hi PR 433 419 405 390 382 376 362 348 334 320 306 298 292 278 264 250 136 LO PR 137 128 120 111 106 103 94 86 77 69 60 55 52 43 35 16 18 DZ4SEA6030 / ASMT60DU1400A MBh 72.40 68.10 63.90 59.70 55.00 50.20 45.60 41.80 39.10 37.10 36.00 34.60 31.10 27.60 24.10 20.60 T/R 44.10 41.90 39.70 37.50 36.20 35.00 31.90 28.90 26.50 24.80 23.50 22.80 21.90 19.70 17.50 15.30 12.10 KW 4.70 4.60 4.60 4.50 4.50 4.40 4.40 4.30 4.30 4.20 4.20 4.20 4.20 4.10 4.10 4.00 AMPS 18.1 17.9 17.7 17.4 17.3 17.2 17.0 16.8 16.6 16.4 16.2 16.0 15.9 15.1 15.5 15.3 15.1 COP 4.52 4.30 4.07 3.85 3.70 3.59 3.31 3.04 2.82 2.66 2.56 2.50 2.41 2.20 1.97 1.74 1.51 Hi PR 412 399 385 372 364 359 345 332 318 305 292 284 278 265 251 238 225 LO PR 128 120 112 104 99 96 88 80 72 64 56 51 48 40 32 24 16 DZ4SEA6040 / ASMT60DU1400A OUTDOOR AMBIENT TEMPERATURE 40 MBh 72.40 68.10 63.90 59.70 57.00 55.00 50.20 45.60 41.80 39.10 37.10 36.00 34.60 31.10 27.60 24.10 20.60 T/R 44.10 41.90 39.70 37.50 36.20 35.00 31.90 28.90 26.50 24.80 23.50 22.80 21.90 19.70 17.50 15.30 12.10 KW 4.70 4.60 4.60 4.50 4.50 4.50 4.40 4.40 4.30 4.30 4.20 4.20 4.20 4.20 4.10 4.10 4.00 AMPS 18.1 17.9 17.7 17.4 17.3 17.2 17.0 16.8 16.6 16.4 16.2 16.0 15.9 15.1 15.5 15.3 15.1 COP 4.52 4.30 4.07 3.85 3.70 3.59 3.31 3.04 2.82 2.66 2.56 2.50 2.41 2.20 1.97 1.74 1.51 Hi PR 412 399 385 372 364 359 345 332 318 305 292 284 278 265 251 238 225 LO PR 128 120 112 104 99 96 88 80 72 64 56 51 48 40 32 24 16 Calculations are based on nominal CFM and 70 °F indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature kW =Total system power 16 www.daikinac.com SS-DZ4SEA AHRI RATINGS ALL AHRI SYSTEM RATINGS ARE ACCESSIBLE IN THE UNITARY MATCHUP TOOL VIA DAIKIN CITY OR IN THE DAIKIN SYSTEM CONFIGURATOR TOOL VIA PARTNERLINK. SS-DZ4SEA www.daikinac.com 17 DIMENSIONS MODELDiMENSIONS DZ4SEA3630 35%:" 35%" 391%6' DZ4SEA3640 35%:" 35%" 391Y16" DZ4SEA4830 35%:" 35%" 367/16" DZ4SEA4840 35%:" 35%" 367/16" DZ4SEA6030 35%:" 35%" 411%6' DZ4SEA6040 35%z" 35%z" 411%6" 18 www.daikinac.com SS-DZ4SEA N N N D HPS 0 CM BUPK CONTROL BOX I BK BK' VL' BL BK RD BIL T1 T2 3TT RDA L7 L2 L30 VVPK BK BK C RD 4FI DR RVC BK EQUIPMENTGROUND SEE NOTE 3 ^L - nDl� ' COMP RI I CH VUPK LPS J��PK K 6K SEE NOTE2 SEE RATING PLATE SEE NOTE 3 1 I I I T1 L1 II C T2 L C T2 11� - T3 C LII COMP TI COMP HVDR 10 WIRING CODE CM Mq�i FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE SEE NOTE OPTIONAL HIGH VOLTAGE---- CH FIELD WIRING HIGH VOLTAGE - R DFT �C DC C CHASSIS GROUND Y LVDR R W2 EARTH GROUND O RVC COMPONENT CODE O HPS UPS C C--------------- CONTACTOR CH ------------- CRANKCASE HEATER CM ------- ---- OUTDOOR FAN MOTOR R COMP------- COMPRESSOR 0 W2 Y DC ------------- DEFROST CONTROL DFT----------- DEFROST THERMOSTAT SEE NOTE 3 SEE NOTE 1 HPS------------ HIGH PRESSURE SWITCH FC------- ----- FAN CAPACITOR NOTES: HVDR-------- HIGH VOLTAGE DEFROST RELAY IO ------- ------ INTERNAL OVERLOAD 1. TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR LPS ------------ LOW PRESSURE SWITCH THERMOSTAT. USE N.E.0 CLASS 2 WIRE. LVDR--------- LOW VOLTAGE DEFROST RELAY 2. CRANKCASE HEATER IS FACTORY INSTALLED OPTION. LVJB ---------- LOW VOLTAGE JUNCTION BOX CRANKCASE HEATER MAY NOT HAVE ADDITIONAL RVC----------- REVERSING VALVE COIL GROUND WIRE. 3. USE COPPER CONDUCTOR ONLY. '}"' ' F% CONTROLS SHOWN WITH THERMOSTAT i IN'OFFPOSITION W-! 0140R01050-A LVJB ID -R H-W2 )R-O SEE NOTE 1 SEE NOTE 3 U -Y COLOR CODE BK------- ------ BLACK BUPK--- -- BLUE/ PINK STRIPE BR--------------- BROWN OR-------------- ORANGE PU--------------- PURPLE RD----- -------- RED WH -------------- WHITE YL--------- -- VELOW VUPK----- ------ YELLOW/PINK STRIPE BL--- -------- -- BLUE Wiring is subject to change. Always Q High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram or the I WARNING sources maybe present. Failure to do so may cause propertydamage, personal injury, or death. 7 unit for the most up-to-date wiring. ACCESSORIES ABK-20A Anchor Bracket Kit X X X X X X FSK01A1 Freeze Protection Kit X X X X X X LAKT011 Low -Ambient Kit X X X X OT18-60A Outdoor Thermostat w/ Lockout stat X X X X X X TXV-FX-KX-3T3 TXV Kit X X TXV-FX-KX-5T3 TXV Kit X X X X ^ Contains 20 brackets; four brackets needed to anchor unit to pad ' Installed on indoor coil a Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidity. 3 Field -installed, non -bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. Our continuing commitment to quality products may mean a change in specifications without notice. 92023 DAIKIN COMFORT TECHNOLOGIES MANUFACTURING. L.P. • Houston, Texas • Printed in the USA. 20 www.daikinac.com SS-DZ4SEA