FIR2022-0042+Calculations+4.15.2022_9.16.05_AM+2804717F I R2022-0042 State of Washington Sprinkler License # Designer: Kenneth H. Robinson RO-BI-NP-*272C2, Level 3 Robinson-Elnislie 1230121st PI SE State of Washington Sprinkler Plumbing Inc Everett, WA 98208 Designer, Certificate of 360-403-7462 Competancy #7659-0106-CE 13 Builder: CC Construction RECEIVED Property address: 8344 Olympic View DR., Edmonds (Lot B) Apr 15 2022 Total quantity of sprinkler heads: 28 CITY E DEVELOPMENT SSERVI ERVICES DEPARTMENT Fire sprinkler system notes: * Fire sprinkler system design per NFPA 13d (standard for houses and duplexes). * Fire sprinkler system to be pressure tested and flow tested. * Sprinkler piping and fittings to be C.P.V.C. "Flameguard" by Speers Mfg. * Installation of C.P.V.C. pipe and fittings to be done by manufacturer certified installers * Sprinkler system to supply water connection for toilets, providing "flow through" in lieu of backflow prevention. Dead end branch lines shall be kept to no more than 20' in length * Sprinkler heads to be Victaulic FL-RES/C concealed pendant with escutcheons per listing. SIN # V4906. * Lines in attic to be protected from freezing with tent insulation (by others). * Design spacing for Victaulic concealed pendant is 16' x 16' (256 square feet). Design Density is minimum .05 gpm/square foot Design area is for 2 head simultaneous flow. * Minimum flow requirements (concealed pendant) are: (1) head flow =13 gpm @ 7.0 psi (flat or sloped ceilings up to 8/12) (2) head flow =13 gpm (ea) @ 7.0 psi (flat or sloped ceilings up to 8/12) JOB: CC CONSTRUCTION ADDRESS: 8344 OLYMPIC VIEW DR, EDMONDS (LOT B) DESIGNER: KENNETH H. ROBINSON-ELMSLIE CALCULATIONS FOR 26 GPM FLOW (2 HEADS) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET 80.00 B: SELECT PIPE SIZE: 1" C: DEDUCT METER & SETTER LOSS (1") 12.00 68.00 DEDUCT BACKFLOW DEVICE LOSS (NONE) 0.00 68.00 D: DEDUCT HEAD LOSS FOR ELEVATION HEIGHT 20 X .434 LBS/FT 8.68 59.32 E. DEDUCT PRESSURE LOSS FROM MAIN TO SRINKLER 1-1/4" WATER SERVICE ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 200 1 200 ELLS: 8 2 16 R-TEES 7 3 21 B-TEES 3 2 6 TOTAL: 243 TOTAL EQUIVALENT FT. X .04 PSI/FT = 9.72 49.60 F: DEDUCT PRESSURE LOSSES FOR 1-1/2" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 0 1 0 ELLS: 0 7 0 R-TEES 0 1 0 B-TEES 0 8 0 TOTAL: 0 TOTAL EQUIVALENT FT. X .0178 PSI/FT = 0 49.60 F: DEDUCT PRESSURE LOSSES FOR 1-1/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 45 1 45 ELLS: 69 6 414 R-TEES 5 1 5 B-TEES 3 6 18 TOTAL: 482 TOTAL EQUIVALENT FT. X .0343 PSI/FT = 16.5326 33.07 F: DEDUCT PRESSURE LOSSES FOR 1" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 55 1 55 ELLS: 2 5 10 R-TEES 7 1 7 B-TEES 2 5 10 TOTAL: 82 TOTAL EQUIVALENT FT. X .1067 PSI/FT = 8.75 24.32 F: DEDUCT PRESSURE LOSSES FOR 3/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 5 1 5 ELLS: 1 4 4 R-TEES 0 1 0 B-TEES 0 3 0 TOTAL: 9 TOTAL EQUIVALENT FT. X .0296 PSI/FT = 0.27 24.05 REMAINING PRESSURE FOR SPRINKLER OPERATION 24.05 CALCULATIONS PER NFPA 13D A.10.4.3 (A) (2013 ED.) IAAiMINGTON STATE ' s MICATE OF COMPETEN" E FED NEIf�T1ON s�IMNKWt sT/TE/E • • Kawo H. Robinson-Eknske • • 76W106-CE level 3 • ftbk1 m Plumbing. Inc. • RQBWP12 IC2 t� • f�••r■••••••••••r• anal