FIR2022-0042+Fire_Sprinkler_Equipment_Specification_Sheets+4.15.2022_9.16.42_AM+2804721
FI R2022-0042 Victaulic° FireLock"' Series FL-RES/C Residential, Quick Response ✓ctaulic Concealed Pendent Sprinklers, K4.9 (7.0) K5.6 (8.0) 43.03 RECEIVED - Ik Apr 15 2022 —� CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT q ` 1.0 PRODUCT DESCRIPTION RESIDENTIAL CONCEALED PENDENT SIN V4906 V3806 ORIENTATION PENDENT PENDENT K-FACTORI 4.9Im ./7.1 S.I. 5.6Im ./8.1 S.I. CONNECTION 1/2" NPT/15 mm 1/2" NPT/15 mm MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) GLOBE RE -DESIGNATION GL4906 — r AVAILABLE WRENCHES SPRINKLER V49 Concealed V38 Concealed PENDENT ■ ■ Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. Operating Pressure: UL: 7 psi/48 kPa/.5 bar Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.com 43.03 16384 Rev B Updated 07/2021 © 2021 Victaulic Company. All rights reserved. 1 �ctauIi c 1144211lir rnm 2.0 CERTIFICATION/LISTINGS D @DS LISTED Listing Agency/ Approved Temperature Max. Coverage Area Minimum Nominal K Factor Ratings Width x Length Flow Pressure Adjustment Spacing Sprinkler 155°F/68°C Deflector to Ceiling/ Cover Ft. x Ft. GPM PSI in Mounting Surface Ft. SIN Imperial S.I? 135°F/57°C m x m L/min kPa mm Distance m 12 x 12 13 7.0 3.7 x 3.7 49.2 1 48 14x14 13 7.0 4.3 x 4.3 49.2 48 7/8 Smooth Ceilings 9 16 x 16 13 7.0 V4906 4.9 7.1 cULus 4.9 x 4.9 49.2 48 22 (See appropriate 2.7 installation detail 18 x 18 17 12.0 5.5 x 5.5 64.3 83 below) OR 20 x 20 20 16.7 6.1 x 6.1 75.7 115 Beamed Ceilings: Installed within the Beam In accordance 12 x 12 16 8.2 3.7 x 3.7 60.6 57 with NFPA 13, 13D, 14x14 - 16 8.2 or13R 4.3 x 4.3 60.6 57 (Max Beam Depth 16 x 16 16 8.2 V3806 5.6 8.1 cULus 1/4 Depends on Edition 8 4.9 x 4.9 60.6 57 6 of Standard) 2.4 18x18 21 14.1 5.5 x 5.5 79.5 97 20 x 20 25 20.0 6.1 x6.1 94.6 138 Z For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. NOTE • Listings and approval as of printing. 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze Bulb Nominal Diameter: 3.0 mm Load Screw: Brass Pip Cap: Brass Spring Seal: PTFE coated Beryllium nickel alloy Frame: Brass Lodgement Spring: Stainless Steel Pin: Stainless Steel Concealed Cup: Steel Cover Plate: Steel Installation Wrench: Ductile Iron Cover Plate Finishes: • Chrome plated • White painted • Flat black painted • Custom painted NOTES • For cabinets and other accessories refer to separate sheet. 43.03 16384 Rev B Updated 07/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaulic virtaidir rnm 4.0 DIMENSIONS 2'M6"/68 mm 23/6"/60 mm — Hole in ceiling Cup Frame j Pip cap and spring seal Bulb Load screw — Pin^ Deflector Cover plate 3'/4"/ 82 mm V3806 V3806 2"/51 mm 13/4"/44 mm Typical ceiling Finished surface m Max. 43.03 16384 Rev B Updated 07/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulic victaulic.com 4.0 DIMENSIONS (CONTINUED) Pip ca sprin Lodgement sl I Loac DE Finished ceil Cover ply« V4906 V4906 mm mm %a"/ 4mm 43.03 16384 Rev B Updated 07/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com M ✓ctauliic victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS _ Read and understand all instructions before attempting to install any Victaulic products. • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from-67°F/-55°C. 1-40: Victaulic FireLockT°^ Automatic Sprinklers Installation and Maintenance Instructions User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 43.03 16384 Rev B Updated 07/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com ✓ctaull 5 Victaulic° FireLockT" Series FL-RES/SW Residential, Quick Response Horizontal Sidewall and Recessed Horizontal Sidewall ✓ctaul;cr Sprinklers, K4.2 (6.0), K4.4 (6.3), K5.6 (8.0) 43.02 1.0 PRODUCT DESCRIPTION RESIDENTIAL PENDENT/RECESSED PENDENT SPRINKLERS SIN V2738 V4431 V2744 ORIENTATION HSW HSW HSW K-FACTOR 4.21m ./6.1 S.I. 4.41m ./6.3 5.1. 5.6 Im ./8.1 5.1. CONNECTION 1/2" NPT/15 mm 1/2" NPT/15 mm 1/2" NPT/15 mm MAX. WORKING PRESSURE 175 psi (1200 kPa) 175 psi (1200 kPa) 175 psi (1200 kPa) GLOBE RE -DESIGNATION — GL4431 — GLOBE EQUIVALENT GL4231 — — CDDIKIVI CD AVAILABLE WRENCHES V27 Recessed V27 Open End Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Min. Operating Pressure: UL: 7 psi/48 kPa/.5 bar Temperature Rating: See tables in section 2.0 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. V56 Recessed ■ V56 Open End ■ ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. vi^F�.dir - 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. 1 ✓ctauli r 2.0 CERTIFICATION/LISTINGS Listing Agency/ I Max. Coverage Deflector to Approved Temperature Area Ceiling/ Mounting Minimum SIN Nominal K Factor Ratings Width x Length Flow Pressure Adjustment Surface Distance Spacing Ft. x Ft GPM PSI in in Ft. Imperial S.I 2 155°F/68°C 175°F/79°C m x m L/min kPa mm mm m 12x12 14 11.1 3.7 x 3.7 53.0 76 14x14 14 11.1 4.3 x 4.3 53.0 76 16x16 17 16.4 4to6 4.9 x 4.9 64.4 113 100 to 150 16x18 19 20.5 4.9 x 5.5 72.0 140 16 x 20 23 30.0 V2738 4.2 6.1 cULus cULus 4.9 x 6.1 87.1 210 12 x 12 15 12.8 3.7 x 3.7 56.8 88 14x 14 17 16.4 4.3 x 4.3 64.4 113 16 x 16 19 20.5 6 to 12 4.9 x 4.9 72.0 140 150 to 300 16 x 18 24 32.6 4.9 x 5.5 90.8 225 16 x 20 28 44.4 4.9 x 6.1 106.0 306 12 x 12 13 8.7 3.7 x 3.7 49 60 14x14 15 11.6 4.3 x 4.3 57 80 16 x 16 4.9x4.9 16 61 13.2 91 V4431 4.4 6.3 cULus cULus 4 to 6 100to150 1/2and 3/4 8 16x18 19 18.7 15and 20 2.4 4.9 x 5.5 72 141 16 x 20 23 27.3 4.9 x 6.1 87 188 cULus - 12 x 12 3.7 x 3.7 15 56.8 7.2 50 - cULus 12 x 12 3.7 x 3.7 16 60.6 8.2 56 14x14 19 11.5 4.3x4.3 71.9 1 80 4to6 16 x 16 23 16.9 100 to 150 4.9 x 4.9 87.1 116 16x18 25 19.9 4.9 x 5.5 94.6 140 16 x 20 4.9x6.1 30 113.6 28.7 198 V2744 5.6 8.1 12 x 12 3.7 x 3.7 17 64.4 9.2 1 63 cULus cULus 14x14 22 15.4 4.3 x 4.3 83.3 106 16 x 16 27 23.2 6 to 12 4.9 x 4.9 102.2 160 150 to 300 16x18 31 30.6 4.9 x 5.5 117.3 211 16 x 20 37 43.6 4.9 x 6.1 140.1 301 2 For K-Factor when pressure is measured in bar, multiply S.I. units by 10.0. NOTE • Listings and approval as of printing. 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 ✓otaulilr 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze 37 Bulb Nominal Diameter: 3.Omm 76 mm 'A6v11 mm Load Screw: Bronze Nominal make -in 15/tBulbo Pip Cap: Bronze 41 mm Spring Seal Assembly: PTFE coated Beryllium nickel alloyDeflectorame Frame: Brass gement spring Lodgement Spring: Stainless Steel Load screw cap and Installation Wrench: Ductile iron spring seal Sprinkler Frame Finishes: V2738 • Plain brass • Chrome plated • White polyester painted 3A6"/ �77mm • Flat black polyester painted A6711 mm Nominal make -in • Custom polyester painted[ja 37 mm NOTE • For cabinets and other accessories refer to separate sheet. Frame )eflector Pip cap and Load screw Bulb spring seal Lodgement spring V4431 3%a"/ �79 mm � VY16'/ 43 mm . '/,6'/11 mm Nominal make -in Frame Deflector Lodgement spring Load screw Bulb Pip cap and spring seal V2744 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctaulicr victaulic.com 4.0 DIMENSIONS 23/,6756 mm 17/t6"/37 mm 127305 mm 47102 mm per NFPA 2156/75 mm Finished surface Typical wall V2738 27/,6762 mm Max. 115/6"/49 mm Min. 47 02 mm "/102 mm Finished surface Typical wall V4431 Finished ceiling 23/6/60 mm 27'/51 mm Hole in wall '/a"/22 mm Max. (3/4) Adj.) - %716 mm Max. (Yz) Adj.) %a"/3 mm Min. IM6717 mm 3/1675 mm Finished ceiling 23/6/60 mm i 2751 mm Hole in wall 21A6775 mm 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 ✓otaulilr victaulic.com 4.0 DIMENSIONS (CONTINUED) 127305 mm 4'7102 mm per NFPA 21 A6775 m 29/,6'/66 mm 2A6753 mm Finished ceiling 23/6"/60 mm 2751 mm Hole in wall _a I Finished surface Typical wall /6"/22 mm Max. (3/4) Adj.) 6/s''/16 mm Max. (Yz) Adj.) %6"/3 mm Min. V2744 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 ✓ctaulicr victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. 6.0 NOTIFICATIONS A WARNING Read and understand all instructions before attempting to install y any Victaulic products. • Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. • The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. • It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. • The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from-670F/-550C. User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, as well as Victaulic performance, maintenance, Victaulic reserves the right to change product specifications, designs and standard safety, and warning instructions. Nothing in this or any other document, nor any verbal equipment without notice and without incurring obligations. recommendation, advice, or opinion from any Victaulic employee, shall be deemed to Installation alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions Reference should always be made to the Victaulic installation handbook or installation of sale, installation guide, or this disclaimer. instructions of the product you are installing. Handbooks are included with each shipment Intellectual Property Rights of Victaulic products, providing complete installation and assembly data, and are available No statement contained herein concerning a possible or suggested use of any material, in PDF format on our website at www.victaulic.com. product, service, or design is intended, or should be constructed, to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual Trademarks property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic and all other Victaulic marks are the trademarks or registered trademarks of or patent applications for articles and/or methods of use in the United States and/or other Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. countries. 43.02 16383 Rev A Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 6 ✓ctauliiic® P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER/RESTRAINER SIZE - SYSTEM PIPE: 3/4" thru 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - D@05 203 - EX 4231, EX 2551 LISTED ALTERNATIVE FOR #500 Pipe Strap 510 Fastener SIZE Dim. rt. - rt 3/4 2.125 1 2.312 1 1/4 3.170 1 1/2 3.400 F2 2 4.010 1/2 4.0 3 5.320 FUNCTION - Support horizontal piping: CPVC, Copper or Steel. Hanger for steel pipe at 15' spacing per NFPA 13. Size 3/4" - 2" Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL D 4D Ds FASTENERS PER NFPA 13 - See table. LISTED FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. Han; uaeo MOUNTING FASTENERS Pipe Wood Wood - Thra 5/8" Gyp Steel — mi.. is GA. CPVC #905 or #10 x1 SMS #14 x 1 1/2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 x1 1/2 SMS or 1/4 x1 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS = Sheet Metal Screw LS = Lag Screw TeG— k=Tek GypScrewsum Buard AFCON #905 screw - custom 5/16" hex head. Restraint Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable order any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. lbilize 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - "OUSTED" 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL -@-s FASTENERS PER NFPA 13 - See table. usrso FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. ORDERING - Part # and pipe size. MOUNTING FASTENERS Pipe Wood Steel — Mfn.la GA. CPVC #905 or #10 x1 SMS #14 or 1/4 Tek Copper #905 or #10 x1 SMS #14 or 1/4 Tek SMS = Sheet Metal Screw Tek=Tek Screw AFCON #905 screw - custom 5/16" hex head. Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 11 ' 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC - STEEL - COPPER HANGER/RESTRAINER SIZE - SYSTEM PIPE: 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - e& ttsreo 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC, Copper or Steel. Hanger for steel pipe at 15' spacing per NFPA 13. Tab up = Hanger. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R and 13D on and CPVC manufacturers instructions. Install on vertical or top mounting surface. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL a@us FASTENERS PER NFPA 13 - See table. usreo FEATURES - Offset edge eliminates abrasion. ORDERING - Part # and pipe size. Hnnaar ® 4i °' MOUNTING FASTENERS am Pipe Wood CPVC/Copper #905 or #10 xl SMS Steel #14 xl 1/2 SMS or 1/4 xl 1/2 LS SMS = Sheet Metal Screw LS = Lag Screw AFCON#905 screw - custom 5/16" hex head. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET HANGER & RESTRAINER CPVC - COPPER - STEEL SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - c 9. usrro 203 - EX 4231, EX 2551 Size 3/4 - 1 1/4: Fastener spacing fits on wood 2 x 4 Installation - Backing Nut Hanger = 1 - at top fastener Restraint = 2 - on each fastene PATENT - No. 6,648,278. FUNCTION - Hanger for support of CPVC or copper pipe. Hanger for steel pipe at 15' spacing per NFPA 13. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. Hanger/ INSTALLATION - Per these instructions RestrainE including NFPA 13, 13R, 13D and CPVC manufacturers. Snap over pipe then squeeze strap back allowing pipe to slide freely. When fastener threads are exposed through wood, install backing nut - See drawing. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL - 41. -s FASTENERS PER NFPA 13 - See table. LWED FEATURES * 1 1/2" Offset * Common center -line for 3/4" and V * Offset edge eliminates abrasion. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. ® 4k " MOUNTING FASTENERS nm�n Pipe Wood Wood - Thru 5/8" Gyp Steel - Min. 18 GA. CPVC #905 or #10 x1 SMS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek Steel/Copper #14 x1 1/2 SMS or 1/4 x1 1/2 LS #14 x 2 SMS or 1/4 x 2 LS #14 or 1/4 Tek SMS = Sheet Metal Screw LS = Lag Screw Gyp-- Gypsum Board Tek=Tek Screw AFCON#905 screw - custom 5/16" hex head. 1.50 r Hanger/Restrainer Hanger/Restrainer �bilize Specific AFCON products are exclusively designed to be compatible ONLY with other AMON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. CAD 1/16 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 DOUBLE OFFSET HANGER & RESTRAINER CPVC SIZE -SYSTEM PIPE: 3/4" and 1" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - `@"' 203 - EX 4231 PATENT - No. 6,702,236 FUNCTION - Hanger for support of CPVC pipe. Seismic restraint - Both horizontal and vertical. Vertical restraint for sprinkler discharge. INSTALLATION - Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers. When fastener threads are exposed through wood, install backing nut. ASSEMBLY/ATTACHMENT - See drawings. SPECIAL D& FASTENERS PER NFPA 13 - See table. LSTED FEATURES * Double 1 1/2" offset with common pipe center -line. * Offset edge eliminates abrasion. * Pipe bore provides robust support for rough job conditions. * Pipe slides easily through bore. ORDERING - Part # and pipe size. Hanger/Restrainer Hanger/Restrainer D 41 DD MOUNTING FASTENERS LISTED CPVC Pipe Wood Hanging/Vertical Restraint #904 or #14 xl 1/2 SMS Horizontal Restraint #904 or #14 xl 1/2 SMS SMS = Sheet Metal Screw * AFCON#904 Screw - custom 3/8" hex head. Specific AFCON products are exclusively designed to be compatible ONLY with other AMON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 1/16 CAD7 Submittal Information for Spears° Manufacturing Company F!J I FlameGuard ° CPVC Fire Sprinkler System Date: Job Name: Engineer: Scope: This submittal covers the Spears® FlameGuard® CPVC Fire Sprinkler System suitable for residential and light hazard occupancies in accordance with The National Fire Protection Association (NFPA). The FlameGuard® System shall be sold as a complete system which consists of pipe, fittings and a specially formulated one-step primerless cement intended for use in wet, dry and pre -action systems in residential and light hazard Applications where the operating temperature/pressure does not exceed 175psi @ 150' F. (1.2 MPa @ 66' C) Product Specification: All CPVC fire sprinkler fittings and pipe shall be Spears® FlameGuard®. All solvent cement shall be Spears® FS-5 One -Step, and all thread sealant shall be Spears@ Blue 75Tm as produced by Spears® Manufacturing Company. All Spears® FlameGuard® CPVC fire sprinkler fittings shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Fittings shall be manufactured in strict compliance to ASTM F438 or F439, as applicable. All CPVC fire sprinkler piping shall be manufactured in the U.S.A. from a Chlorinated Polyvinyl Chloride (CPVC) compound having a minimum cell classification of 23447 in accordance with ASTM D1784. Piping shall be manufactured in strict compliance to ASTM F442. All CPVC solvent cement shall be a primerless, one-step type manufactured in strict compliance to ASTM F493 and approved for use with CPVC fire sprinkler systems. All CPVC fire sprinkler fittings, pipe and solvent cement shall be listed by Underwriters Laboratories (UL®), Underwriters Laboratories Canada (ULC®) and/or Factory Mutual Research Corporation (FM Global) for use in residential and light hazard wet, dry and pre -action systems and bear their authorized certification marks. Thread sealant shall be approved by the fitting manufacturer for use with CPVC fire sprinkler products. All CPVC fittings, pipe, solvent cement and thread sealant shall be certified by NSF International as applicable. Product Marking: FlameGuard® system components shall be orange in color for identification and include required markings and approvals prescribed in ASTM F442 for pipe and ASTM F438 or 439 for fittings. GSFG-0718 Location: Contractor: Installation: Spears® FlameGuard® CPVC Fire Sprinkler System shall carry a working pressure of 175 psi @ 150F (1.2 MPa @ 66' C) and shall be installed in accordance with Spears® Manufacturing Company FlameGuard® CPVC Fire Sprinkler Products Installation Instructions (FG-3) and Addendums. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the Installation Instructions and applicable local codes. Installation practices such as pipe support spacing, bracing, allowance for thermal expansion/contraction, solvent cementing and handling and storage shall be in accordance with the manufacturer's instructions and this specification. Buried pipe shall be in accordance with NFPA 24 for supply mains. The piping system shall be joined using a chemically resistant one-step primerless solvent cement joining process conforming to ASTM F493. The system shall be protected from ultra violet (UV) light exposure from the sun or other source and protected from any chemicals that are not compatible with the CPVC materials including but not limited to fire stopping materials, plasticizers, incompatible thread sealants, etc. NOTE: FlameGuard® CPVC piping systems can be leak tested using oil -free compressed air up to 25psi but must also be hydrostatically tested as required per NPFA standard. Referenced Standards: ASTM D1784 — Rigid Vinyl Compounds ASTM F438 — CPVC Schedule 40 Fittings ASTM F439 — CPVC Schedule 80 Fittings ASTM F442 — CPVC SDR Pipe ASTM F493 — Solvent Cements for CPVC Pipe & Fittings NFPA 13, 13D, 13R — National Fire Protection Association Standards NFPA 24 — Installation — Private Fire Service Mains NSF International Standard 14/61 — Potable Water Approvals: NSF® — NSF International Standard 14/61 — Potable Water Underwriters Laboratories — Listing Agency FM Global —Listing Agency Fit/ OR A NFPA 13D permits "support methods comparable to those required by local plumbing codes." The above hanger/support requirements must also be followed on NFPA 13D systems. CAUTION; DO NOT use hanger items such as plumber's tape or "nail -on" devices. Pipe hanger must comply with NFPA 13, 13D and 13R. When a sprinkler head activates, a significant reactive force can be exerted on the pipe. With a pendent head, this reactive force can cause the pipe to lift vertically if it is not secured properly, especially if the sprinkles' drop is from small diameter pipe. The pipe must be braced against the vertical lift -up with the closest hanger. Refer to the following illustration and Table A & S. Half Suppod ..,, - Spac7ng l Brace/Support � Brace/Support Finished �eofin Lsn Table A - Maximum Support Spacing Distance End Line Sprinkler Head Drop Elbow Pipe Size Line Pressure Line Pressure <100 psi >100 psi Nominal inches (<689kPa) (>689kPa) 3/4 (DN20) 9 inches (228,6 mm) 6 inches (168,3 mrm 1 (DN25) 12 inches (304,8 mm) 9 inches (228,6 mm) 1-1/4 (DN32) 16 inches (406,4 mm) 12 inches (304,8 mm) L1-1=/2-(DN40 DN80) 24 inches (610,0 mm) 12 inches (304,8 mm) Note: Support spacing can be increased by approximately 50% for lower pressures. Table Maximum Support Spacing Distance Inllne Sprinkler Head Drop Tee Pipe Size Line Pressure Line Pressure <100 psi >100 psi Nominal inches (<689kPa) (>689kPa) 3/4 al 4 feet (1,22 meters) 3 feet* (0,91 meters) 1 (DN25) 5 feet (1,52 meters) 4 feet* (1,22 meters) 1-1/4 (DN32) 6 feet (1,83 meters) 5 feet* (1,52 meters) 1-1/2 - 3 (DN40 - DN80) 7 feet (2,13 meters) 7 feet (2,13 meters) Note: *Support spacing can be increased by one foot for lower pressures. FG-3-1010 0 2010 Spears"' Manufacturing Company Page 39 Numerous common methods are used to brace Fire Sprinkler Pipe. A few acceptable methods include: use of a standard band hanger by positioning the threaded support rod to 1/16-inch above the pipe (however, it is important that the rod does not contact the pipe), a wrap around U-hanger, a special escutcheon which prevents upward movement of the sprinkler through the ceiling or bend hangers with Surge Restraints to provide surge protection for the system. Pipe hangers are available that are tested and UL Listed for fire sprinkler service. These hangers comply with NFPA 13 requirements for use with CPVC fire sprinkler piping systems. The following illustrations depict several ofthese. Sand Hanger - designed to support CPVC piping systems when used in conjunction with a hanging steel threaded rod that is suspended from a ceiling or other flat, horizontal surface. The threaded rod must be leveled properly before installing the hanger and restraint. Surge Restraint - when installed with the Sand Hanger, as shown below, provides surge protection for the system. One Hole rap -Around Strap designed to support CPVC piping systems only when the hanger tab is in the vertical position, and the screw -type fastener is in the horizontal position. The one -hole strap can be used as a pipe restrainer when the hanger tab is in the downward position, but it cannot be used as a hanger to hold any weight of the system. In addition, the one -hole strap can be used as a piping system guide when the system lies on top of the beam, and the beam supports the system's weight. The one -hole strap is not intended to support the CPVC piping system from under a ceiling or any other flat, horizontal surface. For this application, install two -hole strap. Guide Hanger Page 40 a 2010 Spears° Manufacturing Company PG-3-1010 Two -Hole Strap - designed to support CPVC piping systems when attached to a flat, horizontal surface with the screw -type fasteners in the vertical position. In addition, the two -hole strap is designed to support CPVC piping systems when attached to a flat, vertical surface with one mounting tab in the vertical position and the screw -type fasteners in the horizontal position. The two -hole strap can be used as a piping system guide when the system lies on top of a beam, and the beam supports the system I s weight. Two -Hole 90' Side Mount Strap - designed to support CPVC piping systems when attached to a horizontal beam with the screw -type fasteners in the horizontal position and the pipe hanging below the beam. The fastener's mounting edges are designed to allow the screws to be installed horizontally. This is a benefit when overhead clearance is limited, In addition, the 900 side mount strap can be used in a restrainer fashion when it is attached to the top of a beam, and the system lies on top of the beam. Risers must be supported by pipe clamps or by hangers located on the horizontal connection close to the riser. Only Listed hangers and clamps can be used, Vertical lines must be supported at intervals to avoid placing excessive load on a fitting at the lower end. This can be done by using riser clamps or double -bolt pipe clamps listed • this service. Kqnpers 2ni. sunnorts must not romDress -distort cut, or abrade th Maintain vertical piping in straight alignment with supports at each floor level or 10-foot intervals, whichever is less. CPVC risers in vertical shafts or buildings with ceilings over 25 feet must be aligned straight and supported at each floor level or 1 0-foot intervals, whichever is less. FG-3-1 010 @ 2010 Spears' Manufacturing Company Page 41 Clamps must not exert compressive stresses on the pipe. If possible, the DJUP-Q-W-arji the mg8ifiei c qlimg rests o.?i tl�e cl,?,?np. AII#w the,, asstmWy to cure befo" placing any stress on the Joint. 414 -W� vr-wbymb M111 the CPVC piping system. For exposed installations that incorporate pendent or sidewall sprinklers, UL Listed support devices for thermoplastic sprinkler piping, or other listed support devices shall be used to mount the piping directly to the ceiling or sidewall. Ween achieved. CAUTION - Refer to the set and cure times listed in this manual for solvent cement joints. Failure to follow these cure times before installing piping systems in trenches could result in joint separation. Trench widths have to be wider where pipe is joined in the trench or where thermal expansion and contraction is a factor, Refer to the "Snaking/Deflection of Pipe" section. Page 42 @ 2010 SpearsO Manufacturing Company FG-3-1 010 SPEARS FlameGuard° CPVC FIRE SPRINKLER PRODUCTS FG-2-0215 Complete System of Pipe, Fittings & Solvent Cement Resistant •Superior F1oW •Ease of Installation Spears® FlameGuard° CPVC Fire Sprinkler Products provide a cost effective alternative to metal systems with advantages of high corrosion resistance, improved system hydraulics, ease of installation and quick assembly with common tools. CPVC Fire Sprinkler Systems are based on proven products Mc RUSPRI"NuR PROMO that have been in continuous service for over 40 years. Spears® FlameGuard° products are approved by UL®, FM® Global, LPCB and Certified by NSF International for potable water use. Check local codes for restrictions and limitations. Corrosion Resistant CPVC Material Does Not Sustain Biological Growth Unlike metal systems, FlameGuard° CPVC products never rust, scale or pit and do not sustain biological growth - a cause of Microbiologically Influenced Corrosion (MIC) which can destroy metal fire sprinkler systems from the inside out. Superior Flow Characteristics for Lower Friction Losses The smooth -wall interior surfaces of FlameGuard° CPVC systems result in reduced friction loss over metal systems. The design flow characteristics remain constant throughout the life of the product because there is no interior corrosion in the system due to microbiological activity. Pressure Rated to 175 psi (1200kpa) @ 150OF (65°C) FlameGuard° CPVC Products are produced in combinations of Schedule 40 and Schedule 80 Fitting configurations con -forming to ASTM F 438 or F 439 standards and FlameGuard° SDR 13.5 CPVC Fire 40 Easy Installation for Lower Costs FlameGuard° CPVC system installations significantly reduce costs over conventional metal piping by virtually eliminating prefabrication. Systems can be fully installed on site using solvent cement joining methods. UL® Listed for U.S. and Canada in NFPA 13,13R & 13D Systems FlameGuard° CPVC Fire Sprinkler Products are UL® listed for U.S. and Canada applications for Light Hazard occupancies as defined in NFPA 13, Residential occupancies up to and including 4-stories as defined in NFPA 13R, and Residential occupancies for one and two family dwellings and manufactured homes as defined in NFPA 131). Consult Spears® FlameGuard° CPVC Fire Sprinkler Products Installation Instructions and NFPA Standards for additional applications including air plenum, system risers, concealed, exposed, underground, combustable attic, garage, basement and low pressure dry piping installations. Sprinkler Pipe conforming to ASTM F 442 standards. Full Limited Lifetime Warranty UL® and FM® Rated working pressure is 175 psi FlameGuard® CPVC Fire Sprinkler Products (1200kpa) @ 150°F (65°C) (LPCB rated to 120°F) carry a limited lifetime warranty against defects (49°C). in material or workmanship. Consult Spears® warranty for additional details. ' NTH``s PROGRESSIVE PRODUCTS FROM SPEARS® OLPCBINNOVATION & TECHNOLOGY ^a h Y Visit our website at www.spearsmfg.com Assessed to ISO 9001: 2008 Certificate number 293 Spears' FlameGuard° ... The Leader in Innovative CPVC Fire Sprinkler System Products Pioneer in Molded -in Metal Insert Head Adapters Patent No. 5,437,481 Spears® pioneered the development of the FlameGuard° molded -in - place metal thread insert for connection of sprinkler heads to CPVC fire sprinkler systems, plus Metal FIPT threaded female adapters for metal - to -plastic transitions. Developed the Special Reinforced (SR) Head Adapters Patent No. 5,582,439 Spears® FlameGuard continuous improvement program developed the technology to produce a superior patented plastic threaded fitting - the Special Reinforced (SR) Design. This unique design incorporates a patented thermoplastic compression process that equalizes stresses generated by tapered thread joint make-up. All CPVC plastic body and threads provide a more uniform construction and improved corrosion resistance. Revolutionary Gasket Sealed Head Adapter Choices Patent No. 8,474,472 - 8,297,663 - 7,458,613 • Requires NO Thread Sealants • Eliminates Stress • Prevents Over Tightening • Provides Easy Frame Alignment Spears® revolutionary Gasket Sealed Head Adapters feature an elastomer gasket seal at the base of the threads. The gasket seal allows a modified thread design that eliminates radial stress and associated problems typical with tapered thread joint make up. Choose from TorqueSafeTA° design with rotating brass thread insert, SofTorqueTm design with Special Reinforced (SR) plastic threads and compressible gasket or QuickTorqueTM with similar features plus brass threads. 0& Ij Lead Free i I ot 4� �11111110 TorqueSafe TM, SofTorqueTM & QuickTorqueTm Fittings Lead Free Full Assortment of Specialty Products & Fitting Configurations Spears® FlameGuard° products provide the specialty fittings needed in today's fire sprinkler systems. The GripLoClrm Elbow, Tee, Cap and Coupling and GripLoClrm Repair Coupling for quick no -cement repairs; the Adjustable Drop Nipple for fine-tuning to finished ceiling height; and Ringed Head Adapter for ease of locating during installation. Plus a full assortment of fittings including Grooved Coupling Adapters, Unions and Flanges sizes 3/4" through 3". Complete Size Range of CPVC Pipe Spears® FlameGuard° CPVC Fire Sprinkler Pipe is available in sizes 3/4" to 3"; and conforms to ASTM F 442 standard for SDR 13.5 CPVC pipe. GripLocTm Elbow, Tee, Cap, Coupling & Repair Couplings Lead Free r- FlameGuard° usa. ML FlameGuard® usA Spears® Solvent Cements & Thread Sealant Fla meGuard°products should be installed using Spears® FS-5 One -Step Solvent Cement. For threaded joints, use Spears® BLUE 75T" Thread Sealant that has been tested for compatibility with FlameGuard° CPVC Fire Sprinkler Products. Spears® TorqueSafe TM, SofTorqueTm and QuickTorqueTm Gasket Sealed Adapter requires no sealant. Consult sprinkler head manufacturer prior to use. © Copyright 2016 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 06/16. FG-2-0215 Description FPPI's complete line of TrimFit Forged Brass", Full Port Ball Valves feature forged components machined to exacting specifications. UL/ULc listed and FM approved. Listed for fire sprinkler systems for trim, test or drain applications, our Full Port Ball Valves are rated 600 PSI for sizes'/4" - 1112" IPS and 300 PSI for the 2" size. Each valve is complete with plastic coated valve handle marked as required by UL. Blow out proof stem. Installation Installation practices consistent with those of the fire sprinkler industry are appropriate for the installation of this product. Always make sure to properly "hold back" the valve and each component being installed to the valve to prevent over tightening or stressing of the valve body. It is also necessary to make sure all components are in proper alignment in the assembly where the ball valve is present. Improper alignment of attached components may create stress on the valve leading to valve failure. Use a suitable thread sealant such as PTFE tape or PipeFit Thread Sealant Paste with PTFE. Never use tape and paste together. We do not recommend the use of anaerobic sealants with this product. The materials used in this sealant type are highly caustic and may cause failure of the synthetic components present in this product. *UL/ULc Listed 2R97 DO NOT USE MORE THAN ONE SEALANT TYPE PER THREADED CONNECTION. DO NOT OVER TIGHTEN THREADS. OVER TIGHTENING WILL CAUSE LEAKS IN THIS AND OTHER THREADED COMPONENTS. The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance and information purposes only. FPPI and its agents cannot assume liability or responsibility for results obtained in the use or misuse of its product by persons whose methods and qualifications are outside and beyond our control. It is the user's responsibility to determine the suitability of, methods of use, preparation prior to use, and appropriate installation for all products purchased from FPPI. It is the user's sole responsibility to observe and adapt such precautions as may be advisable or necessary for the protection of personnel and property in the handling and use of any of our products. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 + 1 (760) 599-1168 + 1 (800) 344-1822 + 1 (800) 344-3775 FAX © 2017 Fire Protection Products, Inc. Specifications Nomenclature and Material: Part: Material: Nut Steel Handle Steel Stem Gland Brass* Stem Packing PTFE Stem Brass* Body Forged Brass' Ball Disc Pack PTFE Ball Disc Chrome Plated Brass or Forged Brass' End Plug Forged Brass' Part No.: Size: Take -Out: 06-838-00 1/4" IPS 111/16" 06-840-00 1/2" 21/16" 06-842-00 3/4" 23/6" 06-844-00 1" 27/a" 06-845-00 11/4" 37/16" 06-846-00 11/2" 313/16" 06-848-00 2" 43/b" "Full port valves have slightly larger "take out" dimensions than standard port valves. You may need to adjust trim components accordingly. "Contains lead. Not for use in water systems intended for human consumption. c Slul FM LISTED APPROVED Model FPPI-PG F P P Description Model FPPI-PG pressure gauges feature an impact and corrosion resistant case made from ABS (plastic) or powder coated steel. Features phosphor bronze bourdon tube movement with white enameled brass dial face with large numbers for easy reading. Dual scale to 300 PSI/2000Kpa. UL/ULc Listed (EX26630) and FM Approved. Applications Standard Features Specifications • Fire sprinkler systems Design • Suitable for all media that will not EN 837-1 & ASME B40.100 Bourdon Tube Material: copper alloy C-type obstruct the pressure system or Sizes attack copper alloy parts 4" (100 mm) Pressure Connection Material: copper alloy Accuracy class 1/4" NPT lower mount (LM) Special Features ± 32/3% of span Movement • UL-listed (UL-393), EX26630 (ASME 1340.100 Grade B) Copper alloy • Factory Mutual (FM) approved The tolerance is reflected in the box associated • Reliable and economical with the zero mark on the face of the gauge. The value is considered zero when the pointer Dial White aluminum with stop pin; falls anywhere within this box. black and red lettering Ranges Pointer 0/80 psi, retard to 250 psi (air) Black aluminum 0/300 psi (aia73water, air/water) Case Working Pressure Black polycarbonate Steady: 3/4 of full scale value Powder coated steel (Air/Water Fluctuating:'/2 of full scale value Gauge only) Short time: full scale value Window Operating Temperature Snap -in clear polycarbonate The information contained herein is produced in good faith Ambient: -40OF to 140OF Item Numbers/Descriptions and is believed to be reliable but is provided for guidance and (-40oCi t0 60o V) 11-550-00 Water Gauge information purposes only. FPPI and its agents cannot assume liability or responsibility for results obtained in the use or misuse Media: 140 oF (+60 0 C) maximum 11-551-00 Air Gauge of its product by persons whose methods and qualifications are 11-552-00 Air Gauge w/Retard outside and beyond our control. It is the user's responsibility to determine the suitability of, methods of use, preparation prior to Temperature Error 11-553-00 Air/Water Gauge use, and appropriate installation for all products purchased from FPPI. It is the user's sole responsibility to observe and adapt such Additional error when tem erature p 11-553-10 Air/Water Gauge w/ precautions as may be advisable or necessary for the protection of personnel and property in the handling and use of any of our o o p o of 68 F (20 C) +0.4 /o for every 18 F Steel Case 11-558-00 Water Gauge, products. (1 O°C) rising or falling. Percentage Personalized 3198 LIONSHEAD AVE of span. 11-559-00 Air/Water Gauge, CARLSBAD, CA 92010 Personalized 11-561-00 Air Gauge w/Retard, + 1 (760) 599-1168 + 1 (800) 344-1822 Personalized + 1 (800) 344-3775 FAX c@us FM 0 2017 Fire Protection Products, Inc. LISTED APPROVED