APPROVED FIR2024-0019+Fire_Sprinkler_Plan+2.27.2024_11.54.48_AM+4085713Approved
DFM CV1r'bs Burt
South County Fire
Date: 02/29/2024
02-29-2024
PLAN REVIEW
NOTES: APPROVED
NO COMMENTS
DFM BURT
EXISTING EXTERIOR (NO MODIFl
NS)S
\
en
fn
},
-
i ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
rr FT ,uw, r
■ ■ ■ ■ ■ ■ ■
4
■ ■ ■ ■ NONE ■ ■ ■ ■ ■ ■ ■ ■ . �-
ALIGN WITH MULLION
■ r
■
RECEPTION
I
■
I
- - - - - - - - - -
- I - - - -
6
- -
- - ---------------
/ "
■ .'1/4 10 -3
I rl
1 1'/4 10'-3"
11/4
■-----------
---- �}--- -
---------- - - - - -�
■
I EXISTING
R
■ Y-0"
'-0" COLUMN
I
■
I
p
1 EXISTING EC
■
I
M
I PENDENT. TYR UNO.
I
■
I \
1
■
I
=
N
■
I
I FULL HT.
■
I
' WOOD CLAD FEATURE
■MT 11/4
1'/4 ,
,)
o
I WALL WITH WOOD
■ N-10- - -A - - - - -
r
10L-04 - - - - - - A - - - - - - - -
-- -
- -1- - - - - LOUVERS/RESIN -
1
■
I
PANEL PER ELEVATION
■
I
■ -
1 A
■
I
t -ID
1
■
I
N
1
1
■
1
■
■
1
c Z
M �
, 2'-0.
1 4
I
J
I
s'
■ OFFICE
OFFICE
�o" 9'- to
b
I
I
ADJACENT SPACE. 1'/4
NIC. ■-----------0
1'/4
T-------� -
---- - - - -
--
■
I A
R `
MT
■
3
I
■
�
I
■
I NEW FULL HT
OC
■
WALLS. TYR UNO.
LU
■
I
o0
OTS
■
'
11-7 CONIC DECK
I
TYP THROUGHOUT
■
■ MT 1'/, A 1'/4 A
■ 4'-10 101-0 1STING
I COLUMN
■�I EMPL6YEE
■ LOUNGE
■
■ Y
■
I
■ W
2 7 3/4 ■ C
■ ]L
I
ONE
Z
■ N
r
W
■
:o
■
EXISTING S�
COLUMN
3a- b ua"
4 - - - ` ■�VIT -4% 11/4
.4
Ir
Ln 5' -0 A 14' -0 A ;i 14--0 q
EXISTING STORAGE , •
Q ALIGN NEW WALL Q
WITH EXISTING _ _■- 7'-E3
OPEN OFFICE
1'/4 _
---- ------
I
I
`v I
� I
fV 1
I
I
a
STORAGE WALL ■
~ I
EXISTING
_ � I
STORAGE 1
I
1
13'-4 7/8"
_ I
1
I
1
FIRST FLOOR FIRE SPRINKLER PLAN
r_ J QtjEWNCE RQQM
�.
1 20'- 4
_ L2
4
A3
5
A3 1
TENANT IMPROVEMENT
THIS PROJECT IS ATENANT IMPROVEMENT. THIS
HILTI HDI-P TZ FACILITY HAS ALREADY BEEN PROTECTED BY FIRE
CONCRETE INSERT SPRINKLER SYSTEM. FIRE SYSTEMS WEST IS ADDING
AND/OR RELOCATING SPRINKLER HEADS TO
ACCOMMODATE THE NEW TENANT WALL, CEILING,
ALL THREAD ROD LIGHTING AND HVAC LAYOUT. ALL WORK WILL BE DONE
WITHOUT AFFECTING THE CAPABILITY OF THE EXISTING
SYSTEM.
RING HANGER
UL 1 FM APPROVED FOR 4" PIPE
CONCRETE INSERT
SYMBOL LEGEND
R i - DENOTES A SPRINKLER HEAD TO BE
- RELOCATED.
A DENOTES A SPRINKLER HEAD TO BE ADDED.
DENOTES EXISTING SPRINKLER HEAD TO BE
BE DEMO OR PLUGGED.
INDICATES EXISTING SPRINKLER TO REMAIN
MT MECHANICAL TEE
- - - - REPRESENTS EXISTING SPRINKLER PIPE.
REPRESENTS NEW SPRINKLER PIPE.
.,
s
• winestore 3
Ider S
(to
Becks Tribute. Center
LAJC.1111�_1S CJ� ,
SCOPE OF WORK
FSW WILL ADD/RELOCATE FIRE SPRINKLER HEADS
TO ACCOMMODATE THE NEW TENANT WALLS IN
EXISTING OFFICE SPACE.
EXCLUSIONS
1. OFF HOURS AND TAXES.
2. RELOCATION OF EXISTING PIPING.
3. GWB CUTAND PATCH.
4. PAINTING OF ANY KIND.
5. WIRING OF ANY KIND.
6. REPLACE, REPAIR, OR MODIFICATION OF CEILING
TILES.
7. ABATEMENT OF ANY KIND.
8. STRUCTURAL VERIFICATION IF REQUIRED.
DESIGN CRITERIA
1. NFPA 13 2019 ED.
2. CITY OF EDMONDS.
3. LIGHT HAZARD
4. OCCUPANCY: A-2
AREA OF WORK
�. CCJ7 -401
•, � Imo'
At- . ,
F
y_
low
VICINITY MAP/ KEY PLAN
SCALE: NONE
City Of Edmonds
Building Department
Work FIRE SPRINKLER MODIFICATION
Address 505 5TH AVE S 104
Owner PACIFIC SAGE PARTNERS
Approved Date
Building Official
Permit Number BLD2024-0019
v IY
SCALE1i4" = 1'-0"
.v
Q
m HANGER LEGEND
SPRINKLER HEADS
REVISIONS
GENERAL NOTES
DESIGN CRITERIAAND NOTES
1
SYM
TYPE
MFG
MODEL
ORIFICE
THREAD
TEMP
FINISH
CANOPY
QTY
MK
DATE
BY
DESCRIPTION
1. ALL MATERIALAND EQUIPMENTTO BE NEW AND UNDERWRITERS APPROVED.
1. ALL BRANCHLINE PIPING TO BE THREADED SCH 40 JOINED W/ CAST IRON FITTINGS (UNO)
2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6")
2. ALL NEW HANGERS TO BE HILTI HDI-P TO CONCRETE STRUCTURE (UNO).
EC PENDENT
TYCO
EC-11
11.2K
3/4"
155'
BRZ
N/A
3
Q
c
WHICH ARE END TO END.
3. ALL NEW HEADS ATACOUSTICAL CEILING TO BE ON FLEX DROP FITTINGS.
3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA#13.
4. ALL NEW CONNECTIONS TO EXISTING PIPE TO BE MADE WITH MECHANICAL TEE (UNO).
n
QR PENDENT
TYCO
TY-FRB
5.6K
1/2"
155°
BRZ
N/A
11
Q
4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA#13.
5-PIPING SHALL BE IN ACCORDANCE WITH NFPA#13.
t
6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA#13.
7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM
FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM.
8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORTTHE SPRINKLER PIPING IS THE
RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE.
APPROVALS REQUIRED:
DISTRIBUTION:
c"v
AHJ
AHJ
1
i
OWNER /ARCHITECT
OWNER /ARCHITECT
1
J_
1
TOTAL
14
FIRE SYSTEMS WEST
1
CONTRACT NAME:
PACIFIC SAGE PARTNERS TI
505 5th Ave S, #104
Edmonds, WA
CONTRACT WITH:
EDGE DESIGN BUILD
1845 NW 195th St
Shoreline, WA 98177
Customer Contact: Suzanne DuBois
Phone: 206-920-2885
RECEIVED
Feb 27 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
I WASHINGTON STATE 1
CERTIFICATE OF COMPETENCY I
I FIRE PROTECTION SPRINKLER SYSTEMS I
Theron J. Davis
8500-0501-C Level
Fire Systems West, Inc.
FIRESWI140B1
I 2/Y7/44 Expires I
` tun _ _ _Date_ _ _12/31/24
SI I
PACIFIC SAGE PARTNERS
TENANT IMPROVEMENT
FIRE SPRINKLER PLAN
s Fire ►ISystems West
It 206 Frontage Road North, Suite C
Pacific, WA. 98047
(253) 833-1248 Fax: (253) 735-0113
WACL# FIRESWI 140B1
Q.C. FAB BY: Q.C. INSTALL BY:
DESIGNER DATE JOB NUMBER SHEET
T DAVIS 2/27/24 1 OF 1