Loading...
FIR2023-0123+Fire_Alarm_Battery_Calculations+12.28.2023_10.51.59_AM+3973846F I R2023-0123 - Global Project Values: SILENT Project Name: FATLAS COFFEE ROASTERS Standby Hours:EKNIGHT 24 Project ID: KL4915 Alarm Mins:�5 Prepared By: FWSFP Derating Factor: 1.2 0: Calculations Date: 12/28/2023 Voltage Drop Warning Version 0. Threshold %: 10 Panel ID: 15808 Model: 5808 Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: 1 ST FLR ELEC ROOM Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5808 5808 CTRL Panel 1 0.170 0.325 SD500-AIM Addr. Input Mod 6 0.003 0.003 SD500-MIM Mini -Input Module 0.000 0.000 SD500-ARM Addr. Relay Module 0.000 0.000 SD500-PS Addr. Pull Station 7 0.004 0.004 SD505-AIS Addr. Ion Smoke Det 0.000 0.000 SD505-AHS Addr. Heat Detector 0.000 0.000 SD505-APS Addr. Photo Smoke Det 1 0.001 0.001 SD505-DUCTR Addr. Duct w/Relay 0.000 0.000 SD505-DUCT Addr. Duct 0.000 0.000 SD500-ANM Addr. Notification Module 0.000 0.000 SD500-LED Addr. LED Module 0.000 0.000 SD500-SDM Addr. Smoke Det. Mod. 0.000 0.000 SD505-6RB Addr. Det. Relay Base 0.000 0.000 SD505-6SB Addr. Det. Sounder Base 0.000 0.000 SD505-61B Addr. Det. Isolator Base 0.000 0.000 SD500-LIM Line Isolation Module 0.000 0.000 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 NAC #1 Notification Appl Circuit 0.000 0.680 #14 Solid 2.52 201 1.01 19.71 3.38% NAC #2 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC #3 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00%D NAC #4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Total Standby Current (Amps) 0.178 1.013 Total Alarm Current (Amps) Alarm Time In Minutes / 60 (5 Mins) Total Alarm AH Required Command Shortcuts Configure Circuits Print Page Standby Time In Hours 24 0.083 Total Standby AH Required 4.265 0.084 Total Combined AH Required 4.35 Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.22 RECEIVED Dec 28 2023 CITY OF EDMONDS DEVELOPMENTSERVICE9 DEPARTMENT Project Information Project Name: ATLAS COFFEE ROASTERS Project ID: KL4915 Prepared By: WSFP Date: 12/28/2023 Ckt. Number: NAC #1 Ckt. Name: Notification Appl Circuit Panel ID: 5808 Use: Notification Appl Circuit Qty Device Current Draw Each Standby Alarm Current Draw Total Standby Alarm 6 WHEELOCK ELHSWC 15CD 0.000 0.037 0.000 0.222 1 WHEELOCK ELHSWC 30CD 0.000 0.046 0.000 0.046 2 WHEELOCK ELHSWC 75CD 0.000 0.077 0.000 0.154 3 WHEELOCK ELSTWC 95CD 0.000 0.086 0.000 0.258 0.000 0.000 Totalsl 0.000 1 0.680 Ckt. Number: NAC #2 Panel ID: 5808 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #3 Panel ID: 5808 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.000 Project Information Project Name: ATLAS COFFEE ROASTERS Project ID: KL4915 Prepared By: WSFP Date: 12/28/2023 Ckt. Number: NAC #4 Panel ID: 5808 Ckt. Name: Notification Appl Circuit Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.000