Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2023-0123+Fire_Alarm_Equipment_Specification_Sheets+12.28.2023_10.52.04_AM+3973847
3SILENT 9 KNIGHT by Honeywell FIR2023-0123 IntelliKnight® 5808 Single Loop Addressable Fire Alarm Control System REDecED 2 2 3 The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports SD or SK protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 99 SK detectors and 99 SK modules. • Built in support for 127 SD devices. • Up to 125 zones and 125 output groups. • Uses standard wire —no shielded or twisted pair required • Built-in digital communicator. • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC. • Distributed, intelligent power. • Drift compensation. • 13 pre-programmed output cadences, (including ANSI- 3.41), and 4 programmable outputs. • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power. • Built-in annunciator with 80-character LCD display. • RS-485 bus provides communication to system accessories. • Built-in RS-232 and USB interface for programming via a PC. • Upload or download programming, event history, or detector status via remote or direct connection. • Improvements in SKSS deliver five times faster upload/downloads. • Built-in synchronization for appliances from AMSECO, GentexO, Faraday, System Sensor®, and Wheelock®- • One Form C trouble relay rated at 2.5A at 27.4 VDC and two Form C programmable relays rated at 2.5A at 27.4 VDC. Model 5808 • Plex-2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions. • Integrated dead front panel protects operator from exposure to electrical components. • The FACP enclosure features a Plexiglass® viewing window to protect annunciator. • Acknowledge function allows operator to keep track of event status. Installation The 5800 can be surface or flush mounted. Compatibility The 5808 signal line circuit (SLC) supports multiple device types of the same protocol: • SK • SD You cannot mix SD and SK SLC devices on a FACP. Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A @ 27.4 VDC Notification Power: 6A @ 27.4 VDC, power -limited Standby Current: 170 mA Alarm Current: 365 mA Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit,power- limited Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet Physical Flush Mount Dimensions: 14.5" W x 24.75" H x 3.5" D (36.8 W x 62.9 H x 8.73 D cm) Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary 5808 Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signalling services. UL Listed CSFM 7165-0559:0142; MEA 429-92-E Vol. XIV OSHPD (CA) OSP-0065-10 S-BUS Accessories 5860/11 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5808. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power -limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5496 Miscellaneous Accessories 5660 Silent Knight Software Suite PC -base software for FACP programming. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-2 Door Dead front cabinet door with clear window to limit access to the FACP. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SK-SCK Seismic Compliance Kit SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are 0 subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA 350386 Rev. L © 2013 Honeywell International Inc. Eluxa horns, horn strobes, & strobes Description The Wheelock Eluxa horns, horn strobes, and strobes by Eaton feature an advanced power saving LED technology with a full range of low and high candela settings for indoor wall and ceiling -mount applications. Designed in sleek, modern enclosures, Eluxa's aesthetically pleasing low profile will blend with the building's interior decor. ..,..,: High efficiency, LED technology -': Eaton's high energy efficient technology leads the industry in lowest current draw for a combined high and low candela device, which reduces overall power consumption. As the first notification T appliances in the industry to utilize LED as the light source, this m breakthrough optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater :_ram number of appliances on the notification appliance circuit and fewer w1 power supplies. This reduces installation and operating costs. All strobe models feature six candela settings: 15, 30, 75, 110, 135, 185 cd on wall models and 15, 30, 75, 110, 150, 177 cd on ceiling models. �HI Low profile design and rich feature set With the industry's smallest footprint, the Eluxa horns, horn strobes, and strobes are aesthetically pleasing to building owners as the i low profile design does not detract from the interior decor. Eluxa is feature rich with 6 candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with �J hinged feature for ease -of -installation, single -gang design (wall models), and no tools needed for setting changes. The ELST strobe, ELHS horn strobe, and the ELHN horn are for 24V operation. ELHN is suitable for 12V applications. Approvals and synchronization Eaton's Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS and Exceder LED3 strobe models. FM,T* N Powering Business Worldwide Technical Data TD450157EN Effective April 2021 Eluxa horns, horn strobes, & strobes Features • Energy efficient • LED technology provides industry's lowest current draw • Fewer power supplies required, smaller wire gage, reduced wire runs • Low -profile design • One of the smallest, most compact single -gang designs • Sleek, modern aesthetics with no visible mounting screws • Special lettering available • 6 Field selectable settings in 1 device • Wall: 15, 30, 75, 110, 135, 185 cd • Ceiling: 15, 30, 75, 110, 150, 177 cd • 3 horn patterns • Continuous,T3, andT3/T4; Fire and CO signaling in 1 device • Sound pressure (Anechoic) dBA • Low 86, High 91 (for Continuous, T3, and T4) • Easy -to -install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single -mount screw in place. • Pre-wire/pre-test capability to check for wiring and ground faults prior to appliance installation • Finger slide switches --No tools needed for setting changes • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting options include ELSBB, any single -gang backbox and to 4" square with adapter kit for wall models and LSPKBB-C backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models • Strobe synchronization • Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Ability to mix xenon and LED strobes in the same field of view • Compliance • NFPA 72 2016 - 20 ms flash duration requirements • U L 1971, U L 1638, U L 464, U LC-S525, U LC-S526 • California State Fire Marshal (CSFM) • RoHS • FCC Part 15, ICES Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ Lifesafetynotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective strobe intensity based on UL 1971. Drawings .39 Figure 1. Wall, horn strobe Figure 2. Ceiling, horn strobe Table 1. Horn ratings per UL/ULC Anechoic Eluxa Horns Regulated Voltage High Low Model Range VDC dB dB ELHN/ELHNC 8.0 - 17.5 0.025 0.020 ELHN/ELHNC 16.0 - 33.0 0.028 0.021 2 EATON www.eaton.com Eluxa horns, horn strobes, & strobes Technical Data TD450157EN Effective April 2021 Table 2. Strobe ratings UL/ULC Max Current ,O 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELST 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 ELSTC 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 Table 3. Code 3 horn strobe ratings UL/ULC Max Current ,C at Anechoic High continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 ELHSC 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 UL/ULC Max Current ,O at Anechoic Low continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 ELHSC 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 Table 4. Specification & Ordering Information Sync w/ DSM or Model Mounting Strobe Candela Red White Lettering Wheelock Power Supplies Horn strobes ELHSR Wall 15/30/75/110/135/185 X FIRE X ELHSW Wall 15/30/75/110/135/185 X FIRE X ELHSR-A Wall 15/30/75/110/135/185 X AGENT X ELHSR-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-A Wall 15/30/75/110/135/185 X AGENT X ELHSW-AL Wall 15/30/75/110/135/185 X ALERT X ELHSW-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELHTRC Ceiling 15/30/75/110/150/177 X FIRE X ELHTWC Ceiling 15/30/75/110/150/177 X FIRE X Strobes ELSTR Wall 15/30/75/110/135/185 X FIRE X ELSTW Wall 15/30/75/110/135/185 X FIRE X ELSTR-A Wall 15/30/75/110/135/185 X AGENT X ELSTR-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-A Wall 15/30/75/110/135/185 X AGENT X ELSTW-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-N Wall 15/30/75/110/135/185 X No Lettering X ELSTR-N Wall 15/30/75/110/135/185 X No Lettering X ELSTW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELSTRC Ceiling 15/30/75/110/150/177 X FIRE X ELSTWC Ceiling 15/30/75/110/150/177 X FIRE X ELSTRC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-EV Ceiling 15/30/75/110/150/177 X EVACUATE X Horns ELHNR Wall X No Lettering X ELHNW Wall X No Lettering X ELHNRC Ceiling X No Lettering X ELHNWC Ceiling X No Lettering X Accessories ELSBB-R LED Backbox, wall ELSBB-W LED Backbox, wall ESB-KIT-R Trim Plate, wall ESB-KIT-W Trim Plate, wall LSPKBB-CR Backbox, ceiling LSPKBB-CW Backbox, ceiling O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. (2) Regulated Voltage Range-VDC Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATON www.eaton.com Technical Data TD450157EN Eluxa horns, horn strobes & strobes EffectiveApril 2021 Table 5. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weight Wall: 0.35 Ibs; Ceiling: 0.55 Ibs Lens Light Emitting Diode (LED) in a rugged Lexan lens Dimensions Wall: 4.79"H x 2.76" W x 1.18" D, Trimplate: 5.25" H x 4.58" W x 0.32" D; Ceiling: 6.27" Diameter x 1.69" D Operating Temperature Indoor: 32°F to 122°F WC to 50°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) Mounting plate included with all models. ELHS and ELST are for wall -mount applications only. ELHN can be used for wall and ceiling -mount applications. Wall mounting: Single -gang, ELSBB backboxes or to 4" square with adapter kit. ELHN can be used for wall and ceiling -mount applications. ELHSC and ELSTC are for ceiling mount applications only. The ELHNC can also be used for wall -mount applications. Ceiling mounting: LSPKBB-C backboxes or to 4" square, 1 1/2" or 21/8"and Octagonal, 1 %s" or 2 1/8"deep Wire Connections #12 through #18 AWG Power & General Operating voltage 12 VDC/VFWR: 8 - 17.5 VDC/VFWR; 24 VDCNFWR: 16 - 33 VDC/VFWR (12 VDC ELHN/ELHNC models only) Strobe Output Rating UL 1971, UL 1638, ULC S526: Selectable 15, 30, 75, 110, 135, 185 candela output for wall models; Selectable 15, 30, 75, 110, 150, 177 candela output for ceiling models Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products, using Wheelock patented svnc protocol Architects and Engineers Specifications The LED notification appliances shall be Wheelock® ELHS audible visual strobe appliances, ELST visual strobe appliances and ELHN audible appliances for wall and ceiling -mount applications with a low - profile design or approved equals. Special lettering, including AGENT, ALERT, EVACUATE, and no lettering, shall be available. The ELHS and ELST strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service and UL 1638 (Visible Signaling Devices. The ELHS and ELHN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All models shall meet the requirements of FCC Part 15 and ICES-003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC/VFWR. The ELHS audible strobe and ELST strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The appliances shall be of low current design. The LED strobe flash duration shall be 20 ms. Where Multi -Candela appliances are specified, the strobe intensity shall have 6 field selectable settings at 15, 30, 75, 110, 135 and 185 candela for wall mount applications and 15, 30, 75, 110, 150 and 177 for ceiling applications. The selector switch for selecting the candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a choice of three (3) horn patterns (high & low WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Life safety & mass notification solutions - 273 Branchport Ave. Long Branch, NJ 07740 Powering Business Worldwide Eaton.com/Lifesafetynotification output): Continuous, T3, and T3/T4 for fire (T3) and CO (T4) signaling The ELHS audible strobe, ELST strobe, and ELHN audible shall include a hinged mounting plate. Mounting options shall include LED backboxes, single -gang backbox and to 4" square with adapter kit for wall -mount models and LED Ceiling backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The ELHS, ELHN and ELST wall models shall have a low profile measuring 4.79"H x 2.76"W x 1.18"D. The ELHSC, ELHNC and ELSTC ceiling models shall have a low profile measuring 6.27" Diameter with 1.69"D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, PS Power Supplies, SAFEPATH products or other manufacturer's panels with built-in Wheelock@ Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash - rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® patented sync protocol. NFPA 72 2016, UL 1971, UL, 1638, UL 464 ULC-S525-16, ULC-S526- 16, CSFM, FCC, RoHS, ICES © 2021 Eaton All Rights Reserved Printed in USA Publication No. TD450157EN April 2021 Eaton is a registered trademark. All other trademarks are property of their respective owners.