Loading...
APPROVED BLD PLN BLD2023-1601+Architectural_Plan+11.21.2023_4.51.55_PM+3914269Zone � RS-6 Corner Setbacks: Required Front 20' Sides 5' Rear Other Height Flag _ Actual ��,_.�„ APPROVED BY PLANNING Jan 08 2024 City Of Edmonds Building Department Work PORCH ALTERATION Address 748 15TH WAY SW Owner JEZIERSKI Approved Date 1 /02/2024 Building Official � lN• � Permit Number BLD2023-1601 PROJECT DATA PROJECT ADDRESS: 748 15TH WAY , EDMONDS, WA 98020 OWNER: TREVOR & MARY JEZIERSKI JURISDICTION: CITY OF EDMONDS, WA ZONE: RS-6 � YEAR BUILT: 1961 � I I LOT SIZE: 0.34 ACRES /� �� � HOUSE: 1,926 SF (EXISTING, NO CHANGE) � ,� I i ,�' ; GARAGE: 480 SF (EXISTING, NO CHANGE) s� ,�,o�� ,'� i TOTAL: 2,406 SF (EXISTING, NO CHANGE) of s � I s�o, �� I I °9n�- i ,'� � HEIGHT: (EXISTING, NO CHANGE) � ' I I I �' ; LEGAL DES.: BEL AIRE DIV A BLK 000 D-00 -LOT 5 ,' I � �'� � PARCEL NUMBER: 00389900000500 � � I �' i I '� I QUARTER: SW ' ' I I ,' I EXISTING CHIMNEY / ��' i SECTION: 25 �� � � �� I I I I I TOWNSHIP: 27 I �� I EXISTING HOUSE TO I i I RANGE: 3 � REMAIN. NO CHANGE I II TO FOOTPRINT. I I I II � � � I I I I I �„ I I I IN / `1 �� NEWOVEORHANGG I �j I 15-0" I ,���P / FRO�S o �� "` i I (REAR SETBACK) \� �Bq�K l I I I � I � � I � ;� I I I ' I \ �� I � I � I � I � I \� I � I I \ � I � I \ � I `, I I � I ` I `� I � I � I \ \�. � I � EXISTING GARAGE TO I I O G� \� REMAIN. NO CHANGE I -��OP TO FOOTPRINT. I I DRAWING INDEX ,QF, I S 'sA I •��, I I \ � ARCHITECTURAL \ I �� `� i I A0.0 COVER SHEET &SITE PLAN �� i I A1.0 GENERAL NOTES \ ��� � A2.0 FOUNDATION PLAN, FLOOR PLAN, &FRAMING PLAN \ ��� ; A3.0 ELEVATIONS A4.0 SECTIONS &DETAILS I STRUCTURAL \ I \ S1.1 STRUCTURAL NOTES S2.1 FOUNDATION, WOOD FRAMING, AND ROOF FRAMING DETAILS APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES N SCALE: 1 " = 20'-0" REVISIONS DATE - PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 VICINITY MAP SITE O EDMONDS WAY ow�3� �UzQ� `�zQ� � w Q � w = � � � U — � L1J oo o z � W � � z O �i o w � — � O � � z � � � ° N Z L1J W RECEIVED Dec 14 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 a U N w 0 J Q 1- m F w a COVER SHEET & SITE PLAN A0.0 G� � � �� �iidnlii� � ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE / IECC (WSEC) TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT CLIMATE ZONE 5 &MARINE 4 R-VALUE U-FACTOR FENESTRATION (B) - 0.30 SKYLIGHT (B) - 0.50 GLAZED FENESTRATION SHGC (B) (E) - CEILING (K) 49 - WOOD FRAME WALL (G) (M) (N) 21 INT - MASS WALL R-VALUE (I) 21 / 21 - FLOOR 30 - BELOWGRADE WALL (C) (M) 10/15/21 INT + 5TB - SLAB R-VALUE &DEPTH (D) 10, 2 FT - TABLE R402.1.1 FOOTNOTES FOR SI: FOOT = 304.8 MM, CI =CONTINUOUS INSULATION, INT. =INTERMEDIATE FRAMING. (A) R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE A101.4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. (B) THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. (C) "10/15121+TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL, OR R15 ON THE CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL. "10115/21 +5TB" SHALL BE PERMITTED TO BE MET WITH R13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL. "5TB MEANS R5 THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL. (D) R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. SEE SECTION R402.2.9.1. (E) FOR SINGLE RAFTER - OR JOIST -VAULTED CEILINGS, THE INSULATION MAY BE REDUCED TO R-38 IF THE FULL INSULATION DEPTH EXENDS OF THE TOP PLATE OR THE EXTERIOR WALL. (F) R7.5 CONTINUOUS INSULATION INSTALLED OVER AN EXISTING SLAB IS DEEMED TO BE EQUIVALENT TO THE REQUIRED PERIMETER SLAB INSULATION WHEN APPLIED TO EXISTING SLABS COMPLYING WITH SECTION R503.1.1. IF FOAM PLASTIC IS USED, IT SHALL MEET THE REQUIREMENTS OF THERMAL BARRIERS PROTECTING FOAM PLASTICS. (G) FOR LOG STRUCTURES DEVELOPED IN COMPLIANCE WITH STANDARD ICC 400, LOG WALLS SHALL MEET THE REQUIREMENTS FOR CLIMATE ZONE 5 OF ICC 400. (H) INT. (INTERMEDIATE FRAMING) DENOTES FRAMING AND INSULATION AS DESCRIBED IN SECTION A103.2.2 INCLUDING STANDARD FRAMING 16 INCHES ON CENTER, 78 PERCENT OF THE WALL CAVITY INSULATED AND HEADERS INSULATED WITH A MINIMUM OF R10 INSULATION. INSULATION &MOISTURE PRO. GENERAL: UNLESS NOTED OTHERWISE, INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODES. INSULATION BAFFLES TO MAINTAIN 1"CLEAR SPACE ABOVE INSULATION. BAFFLES TO EXTEND 6" ABOVE BATT INSULATION & 12" ABOVE LOOSE FILL INSULATION. INSULATE BEHIND BATHTUBS, SHOWERS, PARTITIONS AND CORNERS, PROVIDE FACE STAPLED BATTS OR FRICTION FIT FACED BATTS. PROVIDE 4 MIL (0.004") POLYETHYLENE VAPOR BARRIER AT WALLS OR USE PVA PAINT WITH A DRY CUP PERM RATING OF ONE (MAX.). PROVIDE R-10 INSULATION UNDER ELECTRICL WATER HEATHERS. INFILTRATION CONTROL: 1. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICE THROUGH WALLS, FLOORS, AND ROOF, AND ALL OTHERS SUCH OPENINGS IN THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES, SHALL BE SEALED, CAULKED, GASKETED OR WEATHER-STRIPPED TO LIMIT AIR INFILTRATION. 2. ALL EXTERIOR DOORS, OTHER THAN FIRE -RATED DOORS, SHALL BE DESIGNED TO LIMIT AIR INFILTRATION AROUND THEIR PERIMETER WHEN IN A CLOSED POSITION. DOORS BETWEEN RESIDENCE AND GARAGE ARE NOT CONSIDERED 'FIRE -RATED' AND MUST MEET THE ABOVE REQUIREMENT. 3. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO ADMIT AIR INFILTRATION INTO OR FROM THE BUILDING ENVELOPE WHICH SHALL BE SUBSTANTIATED BY TESTING TO STANDARD ASTM E 283.73. SITE BUILT AND MILLWORK SHOP MADE WOODEN SASH ARE EXEMPT FROM TESTING BUT SHALL BE WEATHER-STRIPPED, CAULKED AND MORE TIGHTLY FITTING. 4. RECESSED LIGHT FIXTURES TO LIMIT AIR LEAKAGE PER W.S.E.C. PIPING FOR HOT WATER/ STEAM SYSTEMS OF PIPING FOR CONTINUOUSLY CIRCULATING HOT WATER SERVICE IS REQUIRED TO BE INSULATED PER THE W.S.E.C. SERVICE WATER PIPING SHALL BE INSULATED TO A MINIMUM OF R-3. � ` ' �7:�:1I_1:7:71�:1.y[e]:��11L1IK�1�/�:�•� AN APPROVED VAPOR BARRIER SHALL BE PROPERLY INSTALLED IN ROOF DECKS, IN ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, AND AT EXTERIOR WALLS. INSET STAPLED BATTS WITH A PERM RATING LESS THAN ONE MAYBE INSTALLED IF THE VAPOR BARRIER IS TO THE WARM SIDE, STAPLES SHALL BE PLACED NOT MORE THAN 8" O.C. AND GAPS BETWEEN THE FACING AND THE FRAMING SHALL NOT EXCEED 1/16". VAPOR RETARDERS AT WALLS PER IRC R702.7 AGROUND COVER OF 6 MIL (0.006") BLACK POLYETHYLENE OR EQUIVALENT SHALL BE LAID OVER THE GROUND IN ALL GROWL SPACES. THE GROUND COVER SHALL BE OVERLAPPED ONE FOOT AT EACH JOINT AND SHALL EXTED TO THE FOUNDATION WALL. WHOLE HOUSE VENTILATION SPECIFICATIONS FROM THE 2015 IRC SECTION M1507. SOURCE SPECIFIC VENTILATION REQUIREMENTS. 1. MINIMUM EXHAUST FAN REQUIREMENTS: A. BATHROOMS, LAUNDRIES AND POWDER ROOMS -50 CFM @ 0.25 W.G. B. KITCHENS -100 CFM @ 0.25 W.G. (RANGE HOOD OR DOWN DRAFT EXHAUST FAN RATED AT MIN. 100 CFM @ 0.10" W.G. MAYBE USED FOR EXHAUST FAN REQUIREMENTS. 2. EXHAUST DUCT REQUIREMENTS: A. INSULATED TO R-4 (MIN.) IN UNCONDITIONED SPACES. B. EQUIP WITH A BACK DRAFT DAMPER. C. TERMINATE OUTSIDE THE BUILDING PRESCRIPTIVE REQUIREMENTS FOR: OPTION 1. INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FANS (IRC M1507.3.4). OUTDOOR AIR SHALL BE SUPPLIED TO ALL HABITABLE ROOMS AT FLOW RATES SPECIFIED IN TABLE M1507.3.3(1) ON THIS SHEET, USING THE FOLLOWING METHODS: 1. ROOM OUTDOOR AIR INLETS SHALL COMPLY WITH THE FOLLOWING: A. HAVE CONTROLLABLE AND SECURE OPENINGS. B. BE SLEEVED OR DESIGNED SO AS TO NOT COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PALCED. C. PROVIDE A MINIMUM OF FOUR SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. D. PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY THE INSTALLATION OF DISTRIBUTION DUCTS, TRANSOMS, INSTALLATION OF GRILLES, UNDERCUTTING DOORS A MINIMUM OF 1/2" ABOVE THE FINISHED FLOOR COVERINGS, OR SIMILAR MEANS. 2. WHOLE HOUSE EXHAUST FANS SHALL: A. BE SIZED ACCORDING TO TABLE M150733(1) ON THIS SHEET. B. BE FLOW RATED AT 0.25" W.G. C. SOUND RATED AT 1.0 SONES MAXIMUM. 3. WHOLE HOUSE EXHAUST FAN CONTROLS: A. BE CONTROLLED BY A 24-HOUR CLOCK TIMER B. PROVIDE CAPABILITY OF CONTRINUOUS OPERATION MANUAL AND AUTOMATIC CONTROL C. THE 24-HOUR CLOCK TIMER SHALL BE READILY ACCESSIBLE. D. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL TIMER SHALL BE SET TO OPERATE THE WHOLE HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. E. A LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS WHOLE -HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" 4. WHOLE HOUSE EXHAUST DUCTS: A. BE INSULATED TO A MINIMUM R-4 IN UNCONDITIONED SPACES. B. TERMINATE OUTSIDE THE BUILDING MECHANICAL GENERAL: SOLID FUEL BURNING APPLIANCES INCLUDING AIRTIGHT STOVES, FIREPLACES STOVES, ROOM HEATHERS, FACTORY BUILDIT FIREPLACES AND FIREPLACE INSERTS. ALL SOLID FUEL BURNING APPLIANCES SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 24 OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. HEATING: EACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A TEMPERATURE OF 68 DEGREES FAHRENHEIT AT A HEIGHT OF 3'-0" ABOVE THE FLOOR AND TWO FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS WHEN THE OUTSIDE TEMPERATURE IS AS SET FORTH IN THE 2015 W.S.C. DEFINITION OF BUILDING ENVELOPE FROM THE 2015 WASHINGTON STATE ENERGY CODE: THE ELEMENTS OF A BUILDING WHICH ENCLOSE CONDITIONED SPACES THROUGH WHICH THERMAL ENERGY MAY BE TRANSFERRED TO OR FROM THE EXTERIOR EXCEPT AS EXEMPTED BY THE 2015 W.S.E.C. 1. FUEL BURNING APPLIANCES LOCATED WITHIN THE BUILDING ENVELOPE SHALL OBTAIN AIR FROM OUTDOORS, MEETING THE PROVISIONS OF CHAPTER 24 OF THE 2015 IRC. 2. FUE BURNING APPLIANCES LOCATED OUTSIDE THE BUILDING ENVELOPE SHALL MEET THE PROVISIONS OF CHAPTER 24 OF THE 2015 IRC. 3. DUCTWORK LOCATION AND SOURCE OF COMBUSTION AIR SHALL MEET THE PROVISIONS OF CHAPTER 16 OF THE IRC. ALL WARM AIR FURNACES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED PER CHAPTER M1402 OF THE 2015 IRC. NO WARM AIR FUNACE SHALL BE INSTALLED IN A ROOM USED OR DESIGNED TO BE USED AS A BEDROOM, BATHROOM, CLOSET OR IN ANY ENCLOSED SPACE WITH ACCESS ONLY THROUGH SUCH ROOM OR SPACE, EXCEPT DIRECT VENT FURNACE, ENCLOSED FURNACES, AND ELECTRIC HEATING FURNACES. NO WARM AIR FURNACE SHALL BE INSTALLED IN A CLOSET OR ALCOVE WITH A SPACE LESS THAN 12" WIDER THAN THE FURNACE OR A CLEARANCE OF 3; ALONG THE SIDES, BACK AND TOP. LIQUEFIED PETROLEUM GAS BURNING APPLIANCES SHALL NOT BE INSTALLED IN A PIT, BASEMENT OR SIMILAR LOCATION WHERE HEAVIER THAN AIR GASES MIGHT COLLECT. APPLIANCES SO FUELD SHALL NOT BE INSTALLED IN AN ABOVE GRADE UNDER FLOOR SPACE OR BASEMENT UNLESS SUCH LOCATION IS PROVIDED WITH AN APPROVED MEANS FOR REMOVAL OF UNBURNED GAS. HEATING AND COOLING APPLIANCES LOCATED IN A GARAGE AND WHICH GENERATE A GLOW, SPARK OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORTS SHALL BE INSTALLED WITH THE PILOTS AND BURNERS OR HEATING ELEMENTS AND SWITCHES AT LEAST 18" ABOVE THE FLOOR SURFACE. FIRE DAMPERS NEED NOT BE INSTALLED IN AIR DUCTS PASSING THROUGH THE WALL, FLOOR OR CEILING SEPARATING A RESIDENCE (GROUP B, DIVISION 3 OCCUPANCY) FROM A GARAGE GROUP M, DIVISION 1 OCCUPANCY), PROVIDED SUCH DUCTS WITHIN THE GARAGE ARE CONSIDERED A STEEL HAVING A THICKNESS NOT LESS THAN 0.019' (N0.26 GALVANIZED SHEET GUAGE) AND HAVE NOT OPENINGS INTO THE GARAGE. WARM AIR FURNACE INSTALLATIONS IN ATTICS OR CRAWL SPACES SHALL COMPLY WITH M1402 OF THE 012 IRC. EVERY APPLIANCE DESIGNED TO BE VENTED SHALL BE CONNECTED TO A VENTING SYSTEM COMPLYING WITH CHAPTER 18 OF THE 2015 IRC. EVERY FACTORY BUILT CHIMNEY, TYPE L VENT, TYPE B GAS VENT OR TYPE BW GAS VENT SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF IT'S LISTING, MANUFACTURERS INSTALLATION INSTRUCTIONS AND THE REQUIREMENTS PER CHAPTER 10 OF THE 2015 IRC. A TYPE B OR BW GAS VENT SHALL TERMINATE PER CHAPTER 24 OF THE 2015 IRC. VENT CONNECTORS SHALL BE INSTALLED WITHIN THE SPACE OR AREA IN WHICH THE APPLIANCE IS LOCATED AND SHALL BE CONNECTED TO A CHIMNEY OR VENT IN SUCH A MANNER AS TO MAINTAIN THE CLEARANCE TO COMBUSTIBLES PER SECTION M1803 OF THE 2015 IRC. HEATING EQUIPMENT: ALL HEATING EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE 1987 NATIONAL APPLIANCE ENERGY CONSERVATION ACT (NAECA) AND BE SO LABELED. EQUIPMENT SHALL ALSO COMPLY WITH SECTION 1411 OF THE 2015 W.S.E.C. DUCTWORK: 1. DUCT SYSTEMS OR FACTORY BUILT AIR DUCTS SHALL BE OF METAL AS SET FORTH BY TABLE 1601.1.1 (1) & 1601.1.1 (2) OF THE 2015 IRC. 2. RECTANGULAR, FLAT, OVAL AND ROUND DUCT JOINTS AND SEAMS SHALL BE AIRTIGHT PER SECTION M1601.4.1 OF THE 2015 IRC. 3. INSTALLATION OF DUCTS SHALL COMPLY WITH SECTION M1601.3 OF THE 2015 IRC. 4. DUCT INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH SECTION M1601.3 OF THE 2015 IRC. 5. FINAL DUCT LEAKAGE AFFIDAVIT IS TO BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO FINAL INSPECTION. DUCT LEAKAGE AND SEALING REQUIREMENTS IN 2015 W.S.E.C. SECTION 503.10 TO BE MET. DOORS, WINDOWS &SKYLIGHTS GENERAL: THE REQUIRED EGRESS DOOR MAY HAVE A MAXIMUM 7 3/4" STEP FROM TOP OF THE THRESHOLD TO A MIMUM 36" DEEP LANDING ON THE EXTERIOR SIDE OF THE DOOR. OTHER EXTERIOR DOORS MAY HAVE A MAXIMUM (2) 7 3/4" STEPS TO A MIN. 36" DEEP LANDING. ALL GLAZING SHALL MEET THE REQUIREMENTS OF THE 2012 W.S.E.C. TABLE 6-1 UNLESS NOTED OTHERWISE. ALL SKYLIGHTS AND SKYWALLS SHALL HAVE LAMINATED GLASS UNLESS NOTED OTHERWISE. ALL BEDROOM EMERGENCY EGRESS WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. MINIMUM NET CLEAR OPERABLE WIDTH OF 20" AND A MINIMUM NET CLEAR OPENING HEIGHT OF 24", MAXIMUM SILL HEIGHT OF 44' MEASURED FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING. OPERABLE WINDOWS WITH A SILL OF MORE THAN 72" ABOVE FINISHED GRADE AND WITHOUT AN ADJACENT ROOF WITH MAX. 4:12 SLOPE, TO BE A MINIMUM OF 24" ABOVE ADJACENT FINISHED FLOOR. SAFETY GLAZING LOCATIONS PER 2015 IRC SECTION R308.4 R308.4.1 GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOORS. R308.4.2 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. R308.4.3 GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: 1. THE EXPOSED AREA OF AN INDIVIDUAL PANEL IS LARGER THAN 9 SQUARE FEET 2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18" ABOVE THE FLOOR 3. THE TOP EDGE OF THE GLAZING IS MORE THAN 36" ABOVE THE FLOOR 4. ONE OR MORE WALKING SURFACES ARE WITHIN 36" MEASURED HORIZONTALLY AND IN A STRAIGHT LINE OF THE GLAZING. R308.4.4 GLAZING IN GUARDS AND RAILINGS, INCLUDING STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN -FILL PANELS, REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE. R308.4.5 GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRPOOLS, SAUNAS, STEAM ROOMS, BATHRUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. R308.4.6 GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES (914 MM) ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS. R308.4.7 GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN 60 INCHES (1524 MM) HORIZONTALLY OF THE BOTTOM TREAD. FOR EXCEPTIONS SEE IRC SECTION R308.4 CARPENTRY GENERAL: ALL FRAMING SHALL COMPLY WITH THE APPLICABLE SECTIONS) OF THE 2015 IBCI IRC. PRESSURE TREATED WOOD REQUIRED IN LOCATIONS LISTED IN IRC R317.1 • 2"MINIMUM VERTICAL CLEARANCE BETWEEN WOOD &CONCRETE STEPS, PORCH SLABS, PATIO SLABS &OTHER SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER. • 6" MINIMUM CLEARANCE BETWEEN WOOD AND EARTH. • 8" MINIMUM CLEARANCE BETWEEN UNTREATED MUSILLS AND EARTH. • 12"MINIMUM CLEARANCE BETWEEN FLOOR BEAMS AND EARTH. • 18"MINIMUM CLEARANCE BETWEEN FLOOR JOISTS AND EARTH. LOADING: ROOF15 PSF DEAD LOAD + 25 PSF LIVE LOAD = 40 PSF FLOOR 10 PSF DEAD LOAD + 40 PSF LIVE LOAD = 50 PSF CEILING 5 PSF DEAD LOAD + 10 PSF LIVE LOAD = 15 PSF DECK 5 PSF DEAD LOAD + 40 PSF LIVE LOAD = 45 PSF INTERIOR PARTITION = 7 PSF EXTERIOR PARTITION = 10 PSF WOOD BEARNING ON OR INSTALLED WITHING 1/2" OF MASONRY OR CONCRETE TO BE TREATED WITH AN APPROVED PRESERVATIVE. SOLID BLOCKING OF NOT LESS THAN 2X THICKNESS SHALL BE PROVIDED AT ENDS AND AT ALL SUPPORT OF JOISTS AND RAFTERS. ANCHOR BOLTS TO BE PER SHEAR WALL SCHEDULE AND FOUNDATION IRC. 7" MINIMUM EMBEDMENT. ALL METAL FRAMING ANCHORS AND HANGERS SHOWN ON DRAWINGS SHALL BE STRONG TIE CONNECTORS AS MANUFACTURED BY SIMPSON COMPANY. PROVIDE FIREBLOCKING IN CONCEALED SPACES OF STUD WALLS &PARTITIONS, INCLUDING FURRED SPACES &PARALLEL ROWS OF STUDS OR STAGGERED STUDS AS FOLLOWS: 1. VERTICALLY AT THE CEILING &FLOOR LEVELS. 2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET. I PROVIDE FIREBLOCKING AT OTHER LOCATIONS PER 2015 IRC R302.11 GENERAL PLANS COMPLY TO THE 2015 INTERNATIONAL RESIDENTIAL CODE. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS HAVE BEEN MADE. IT IS THE CONTRACTORS RESPONSIBILITY TO IDENTIFY ALL DESCREPANCIES TO THE ARCHITECT AT THE TIME THEY ARE NOTED. DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. CODES: ALL APPLICABLE COES AND AUTHORITIES HAVING JURISDICTION SHALL BE FOLLOWED. 1. 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) WITH WASHINGTON STATE AMENDMENTS (WSA) EXCEPT CHAPTERS 11 AND 25 THROUGH 42 ARE NOT ADOPTED. WAC 51-51 2. 2015 INTERNATIONAL BUILDING CODE (IBC) WITH WASHINGTON STATE AMENDMENTS (WSA) WAC 51-50 3. 2015 INTERNATIONAL MECHANICAL CODE (IMC) WITH WASHINGTON STATE AMENDMENTS (WSA) WAC 51-52 4. 2015 UNIFORM PLUMBING CODE (UPC) WITH WASHINGTON STATE AMENDMENTS, WAC 51-56 5. 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS, WAC 51-54A 6. 2015 WASHINGTON STATE ENERGY CODE, RESIDENTIAL PROVISIONS (WSEC), WAC 51-11 R BUILDING: CONSTRUCTION TYPE: V-B OCCUPANCY GROUP: R-3 LOCAL JURISDICTION REQUIRES DWELLING UNIT FIRE SPRINKLER SYSTEM PER IRC APPENDIX R YES NO CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA WIND DESIGN SUBJECT TO DAMAGE FROM ICE SEISMIC WINTER BARRIER AIR MEAN GROUND DESIGN DESIGN UNDER- FLOOR FREEZING ANNUAL SNOW LOAD CATEGORY TEMP LAYMENT HAZARDS INDEX TEMP SPEED OPOGRAPHI FROST LINE REQUIRED (MPH) � EFFECTS WEATHERING DEPTH TERMITE DECAY 25 PSF 110 - D MODERATE �8" MODERATOS MODERATOS - NO SITE WORK ALL FOOTINGS TO BEAR ON FIRM, UNDISTURBED EARTH BELOW ORGANIC SURFACE ALL BACK FILL MATERIAL SHALL BE THOROUGHLY COMPACTED. FOUNDATION VENTS SHALL NOT INTERFERE WITH THE DIRECT LOAD PATH OF COLUMNS. ow�3� �UzQ� � � w z Q � Q 3 � w _ = ~ � �; U - � oo o z W � W � � z � �i o w � O � � � z � � � ° Z N L1J W RECEIVED Dec 14 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z 0 U W 0 Q m H w GENERAL NOTES IL KEYNOTES A NEW EXTERIOR INFILL WALL PER SCHEDULE B SOLID CORE WOOD EXTERIOR DOOR CONFIRM SIZE /FINISH WITH OWNER EXISTING FOUNDATION TO REMAIN i ii -�- � J i i i _ i �i i � � � i NEW 6" MIN. CONC. SLA 'ii i ON GRADE W/ #4 � 18� �� � o L� O.C. EW CTRD. 111 4 o L` i i ii i � � FOOTING PER DETAIL S2.1 `� � � � i i � REMOVE EXISTING SAND TYP. \��� \� \` _� i � SET BRICK PAVERS FOR ���� i ^' } �'�� ��, ,' i INSTALLATION OF NEW ® SLAB ON GRADE � ® � � � --- --J � i i / / ���� / / � � � � ��� CONFIRM EXTENT OF Tv��,, ��_�» � � 8,_1�„ CONC. SLAB ON GRADE PATH WITH OWNER PRIOR TO (V.I.F.) � � CONSTRUCTION. i i � � FOOTING PER DETAIL � i � CONFIRM EXTENT OF NEW CONC. � i SLAB ON GRADE PATH WITH OWNER � PRIOR TO CONSTRUCTION. LEGEND ----------- CONSTRUCTION ABOVE NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN GENERAL NOTES WALL TYPE SCHEDULE 1. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS &CONDITIONS PRIOR TO CONSTRUCTION. TYPE DESCRIPTION 2. DIMENSIONS ARE FROM FACE OF STUD. EXTERIOR INFILL 3. PROVIDE SOLID BLOCKING OVER SUPPORTS. � SIDING (TO MATCH EXISITNG) 4. WINDOW &DOORS ARE SHOWN & NOTED AS NOMINAL SIZES. W.R.B. 5. ALL WOOD IN CONTACT WITH CONC. TO BE PRESSURE TREATED. 15/32" APA RATED PLYWOOD W/ 8d @ 6" O.C. PANEL EDGES & 8d @ 12" O.C. 6. SEE GENERAL NOTES FOR ADDITIONAL NOTES. WOOD STUDS TO MATCH EXISTING @ 16" O.C. 7. ALL EXTERIOR WALLS TO BE NAILED PER SHEARWALL SCHEDULE. 8. ALL BMS / HDRS LONGER THAN 6'-0" TO BE SUPPORTED W/ (2) TRIMMERS. VAPOR BARRIER (WARM SIDE) 9. WATER RESISTIVE TYPE "X" GYPSUM WALL BOARD AT ALL WET AREAS. 1l2" GYPSUM WALL BOARD 10. INSTALL SHEAR WALLS & / OR BLOCKING IN ROOF STRUCTURE BEFORE INSTALLING FINISH ROOFING. FINISH PER OWNER ;Insulation to meet the 2018 � iWSEC. �2x4 to be a minimum R15 ; � • :2x6 to be a minimum R-21 � • � • ..........................a HEIGHT FULL HEIGHT 1 A3.0 1 2 A4.0 A3.0 FOUNDATION PALN 2 FLOOR PLAN 3 ROOF FRAMING PLAN �'� SCALE: 3/8" = 1 ' 0" z A2.0 SCALE: 3/8" = 1 '-0" z A2.0 SCALE: 3/8" = 1 ' 0" z �W� 3� o `� U z Q w w � _ � _ � � vi U — � oo � Z � W \W\ � � Z � � / p w �� O — ` , Y N �/ Z ° � Z N W w RECEIVED Dec 14 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N o x FLOOR PLANS ■ nines Tnn�i i nnuini nnnnnin nnin �ni �e NEW FASCIA BD. &CONCEALED GUTTER TO MATCH EXISTING. � T.O. BEAM � B.O. SOFFIT � T.O. SLAB � T.O. FTG. NEW POSTS PER PLAN, FINISH PER OWNER nines Tnnni i nneeini nnnnnin nnin nni �i SOUTH ELEVATION SCALE: 1 /4" = 1 '-0" T.O. BEAM B.O. SOFFIT T.O. SLAB T.O. FTG. GENERAL NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH RESPECTIVE CONTRACTOR TO COORDINATE WITH THE OTHER TRADES, FAILURE TO DO SO WILL NOT CONSTITUTE GROUNDS FOR A CHANGE ORDER. 2. CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY OF ALTERATIONS TO EXTERIOR DESIGN. LEGEND EXISTING LAP SIDING EXISTING ASPHALT SHINGLE ROOFING // GLASS /WINDOW ow��� `� Uz Q� w wQ =� ~ � vi U — � oo � z LJJ � z W % � � O � o w � O � — � � z � � � ° Z N ww RECEIVED Dec 14 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N o x J Q z ~ o � � � � m o' � U � � � Lu � o � w o_ ELEVATIONS 2 WEST ELEVATION A3.0 SCALE: 1 /4" = 1 ' 0" A3.0 OVERHANG SOFFIT PTD. MTL. 2X2 ANGLE COVERED ENTRY EXPOSED GRADE 2X4 CEDAR I SLAT WALL, FINISH PER I OWNER PT. 4X4 POST (BEYOND), I WRAP IN SIDING AND PAINT PER OWNER PTD. MTL. 2X2 ANGLE EXISTING BRICK PATIO TO REMAIN � I w z J o' w �I z w U Q �I Q SCREEN WALL SE SCALE: 1 -1 /2" = 1 ' -0" STREET PT. 4X4 POST PER PLAN, WRAP IN SIDING AND PAINT PER OWNER PTD. 3" MTL. STRAP AT CENTERLINE OF SLAT WALL (IF NECESSARY TO PROVIDE STABILITY) EXPOSED GRADE 2X4 CEDAR SLAT WALL, FINISH PER OWNER SLAT WALL CENTERLINE PTD. 4X2 MTL. POST 3" TYP. COVERED ENTRY STREET CTION � SCREEN WALL PLAN SHED ROOF CONSTRUCTION TORCH DOWN ROOFING (MATCH EXISTING) W.R.B. UNDERLAYMENT (MATCH EXISTING) PLYWOOD SHEATHING PER PLAN 2X JOIST PER PLAN 2X SOFFIT SOFFIT FINISH PER OWNER T.O. BEAM B.O. SOFFIT SOFFIT FINISH PER OWNER W/ RECESSED LIGHTS T.O. SLAB T.O. FTG. PT POSTS PER PLAN, WRAP IN CEDAR SIDING, PT. PER OWNER NEW SLAB ON GRADE PER PLAN T.O. FOUNDATION TO BE UNDER BRICK PATIO, CONTRACTOR TO VERIFY. SCALE: 1 -1 /2" - 1 ' -0" BUILDING SECTION SCALE: 1 /4" = 1 ' 0" TORCH DOWN ROOFING PER ELEVATIONS, TYP. PLYWOOD SHF^Tuinir n�o ROOF UNI METAL EAVE FL HEMMED EDGE BE GUTTER STRAP @ MINIMUM FASCIA BOARD, CONFIRM PAINT COLOR WITH OWNER. CONCEALED 6" P METAL GUTTE EXISTING, OVERL. LEG OF EAVE FL GUT - FASCIA BOARD, CO COLOR SECONDARY (NON ROOF EAVE CONTRACTOR TO VERIFY NEW ROOF JOIST DOES NOT CONFLICT W/ EXISTING SKYLIGHT TO REMAIN FILL CAVITY W/ INSULATION 2X PT BLOCKING SHED ROOF CONSTRUCTION TORCH DOWN ROOFING (MATCH EXISTING) W.R.B. UNDERLAYMENT (MATCH EXISTING) PLYWOOD SHEATHING PER PLAN 2X JOIST PER PLAN 2X SOFFIT SOFFIT FINISH PER OWNER T.O. BEAM TO MATCH T.O. EXIST. PLATE, CONTRACTOR TO VERIFY T.O. BEAM - B.O. SOFFIT B.O. SOFFIT W/ RECESSED LIGHTS TO BE LOWER THEN EXISTING FASCIA BD., CONTRACTOR TO VERIFY PORTION OF EXISTING OVERHAND, 8c CONCEALED GUTTER /DOWNSPOUT TO BE REMOVED, TYP. T.O. SLAB TYP. EL.: 0'-0" T.O. FTG. PT POSTS PER PLAN, WRAP IN CEDAR SIDING, PT. PER OWNER, SECONDARY (NON—STRUCTURAL) POST @ 10° T.O. FOUNDATION TO BE UNDER BRICK PATIO, CONTRACTOR TO VERIFY. NEW SLAB ON GRADE PER PLAN ROOF JOIST nrn ni nni TORCH DOWN RC UN[ PLYWOOD SHEATHING PERIMETER 24 GA. PRE -FINISHED METAL EAVE FLASHING WITH HEMMED EDGE INSTALLED OVER UNDERLAYMENT, TO MATCH EXISTING. -ASCIA BOARD TO MATCH EXISTING, CONFIRM PAINT COLOR WITH OWNER. SOFFIT TO MATCH EXISTING, CONFIRM PAINT COLOR WITH OWNER. PT POST PER PLAN, WRAP IN SIDING AND PAINT PER OWNER ROOF RAKE SCALE: 1 -1 /2" - 1 ' -0" d P.T. POST PER PLAN WRAP POST IN SIDING, PT. PER OWNER T.O. SLAB ON GRADE EMBEDDED POST a FOOTING &REINFORCING 4/S2.1 FOUNDATION SCALE: 1 " - 1 '-0" BUILDING SECTION SCALE: 1 /4" = 1 '-0" ow��� `� Uz Q� w � � w _ ~ � vi U — � oo � Z � Z w \w\ / � � � � � w O � Z � ° Z N w w i RECEIVED Dec 14 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT oN X J Q z ~ o m U � � � w o w SECTIONS ■ STRUCTURAL NOTES C G (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 10 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). EARTHQUAKE LOADS: EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-16 SECTION 12.8. SITE CLASS (ASSUMED) D SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.280 ONE SECOND SPECTRAL RESPONSE ACCEL (SI) 0.450 SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 1.024 ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.555 RISK CATEGORY II SEISMIC IMPORTANCE FACTOR (IE) 1.0 SEISMIC DESIGN CATEGORY D BASIC SEISMIC FORCE -RESISTING -SYSTEM CANTILEVER COLUMN/TIMBER FRAME RESPONSE MODIFICATION FACTOR, (R) 1.5 REDUNDANCY FACTOR (p) 1.0 SEISMIC RESPONSE COEFFICIENT (CS) 0.683 W =TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-16 SECTION 12.7.2. BASE SHEAR (V), V = CSW = RD I W WIND LOADS: BASIC WIND SPEED (3 SECOND GUST) 110 MPH EXPOSURE B KZT 1.0 SEE PLANS FOR ADDITIONAL DESIGN LOADS. STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC. STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. FREQUENCY AND DISTRIBUTION OF REPORTS -INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: NOT AVAILABLE AT TIME OF DESIGN ALLOWABLE SOIL PRESSURE: 1500 PSF (ASSUMED) LATERAL BEARING PRESSURE: 200 PSF (ASSUMED) FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BYTHE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACI<FILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557-00. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH SECTION CHAPTER 5 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (f'c) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD * ALL CONCRETE 4000 PSI 0.50 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 5 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BEAIR-ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 4.2.1 FOR MODERATE EXPOSURE CONDITION. *PROVIDE 4000 PSI MINIMUM CONCRETE STRENGTH AS REQ'D FOR CONCRETE DURABILITY REQUIREMENTS. 2500 PSI f'c CONCRETE MEETS STRENGTH REQUIREMENT FOR DESIGNED FOOTING, THEREFORE SPECIAL INSPECTION OF CONCRETE MIXTURE AND PLACEMENT IS NOT REQUIRED. REFER TO THE SPECIAL INSPECTION TABLE ABOVE FOR ADDITIONAL SPECIAL INSPECTION REQUIREMENTS. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI 318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. MINIMUM LAPS AND EMBEDMENT UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: f'c = 4000 PSI DEVELOPMENT LENGTH LAP SPLICE BAR TENSION COMPRESSION TENSION COMPRESSION SIZE TOP BARS gARS ALL BARS TOP BARS gARS ALL BARS #3 19 15 8 24 19 12 #4 25 19 10 33 25 15 #5 31 24 12 41 31 19 #6 37 29 15 49 37 23 #7 54 42 17 71 54 27 #8 62 48 19 81 62 30 NOTE: 1. ALL LENGTHS ARE IN INCHES. 2. ALL LAP SPLICES ARE CLASS B. 3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" CONCRETE EXPOSED TO EARTH AND WEATHER: #5 BARS AND SMALLER 1 1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS AND JOISTS 3/4" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3" FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BYTHE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BYTHE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK � MIN LENGTH 8d COMMON 0.131Q� 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.148Q1 3 1/4" SHANK 16d COMMON 0.162Q� 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"� x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 11.1.3. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BYTHE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG =HOT DIP GALVANIZED SST300 =TYPE 316E STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.4. TYPICAL FRAMING NOTES 1. BEARING WALL FRAMING 2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO. REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR &WINDOW HEADERS NOT CALLED OUT ON THE PLANS. HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO. COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT OTHERWISE SHALL BE TWO STUDS. 2. WALL BASE PLATE ON CONCRETE WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS, BOLT PLATES OR SILLS TO CONCRETE WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH MINIMUM EMBEDMENT. PLACE AT 5'-0" OC MAXIMUM FOR SHEAR WALLS, AND AT 6'-0" OC FOR BEARING WALLS AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF EITHER END TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE WASHERS. 3. ROOF AND FLOOR FRAMING PROVIDE 1 1/2" BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM UNO. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. 4. DIAPHRAGM NAILING ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS. THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. 5. ALLOWABLE STUD AND PLATE PENETRATIONS CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. 6. GYPSUM WALLBOARD NAILING ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE WALL. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. FOUNDATION PLAN NOTES: 1. UNLESS NOTED OTHERWISE, EXTERIOR FOOTINGS SHALL BEAR A MIN OF 1'-6" BELOW ADJACENT GRADE. 2. FOOTINGS AND SLAB ON GRADE SHALL BEAR ON FIRM NATIVE SOIL OR COMPACTED STRUCTURAL FILL. 3. PLACE ALL REINFORCEMENT PER THE STRUCTURAL NOTES AND FOUNDATION DETAILS. REFER TO SHEET 51.1 FOR ADDITIONAL CONCRETE DETAILING REQUIREMENTS. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, WALL LOCATIONS, AND CONCRETE ROUGH OPENINGS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ALL PARTIES OF ANY DISCREPANCIES. TYPICAL ROOF FRAMING PLAN NOTES: 1. WALLS SHOWN ON ROOF FRAMING PLAN ARE WALLS BELOW ROOF FRAMING. 2. ROOF SHEATHING SHALL BE 1/2" PI 40/20 WITH 8d COMMON NAILS SPACED AT 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, SHEAR WALLS, COLLECTOR TRUSSES, AND BLOCKING OR TRUSS BLOCKING PANELS INDICATED ON PLANS. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. REFER TO DETAIL 1/52.1 FOR SHEATHING LAYOUT AND NAILING. 3. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN. 4. REFER TO DETAIL 2/52.1 FOR CONSTRUCTION OF MULTIPLE STUD COLUMNS. 5. ALL DIAPHRAGMS UNBLOCKED UNO. 6. COLUMNS AND BEARING WALLS SHOWN ON PLAN SHALL BE CONTINUED DOWN TO THE FOUNDATION UNLESS CARRIED BY A BEAM BELOW. 7. ATTACH ALL RAFTERS TO WALLS BELOW WITH SIMPSON H2.5 HURRICANE TIES. 8. UNLESS NOTED OTHERWISE, ALL JOIST -TO -BEAM CONNECTIONS SHALL BE SIMPSON HU SERIES FACE MOUNT HANGERS WITH MAX NAILING. 9. UNLESS NOTED OTHERWISE, ALL BEAM -TO -POST CONNECTIONS SHALL BE SIMPSON CCQ OR ECCQ COLUMN CAPS. ENGINEERIIVC, 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 � G ' GAL g� of wAs.� �s c-� tt7► o � �' O��C►�,�39553 ,�i ' ORAL ��`Y S`�IGNAL 10/ 09/ 2� J a F- F- Z O m � � W N (Y ~ C� � (n � W w 0 a m W � � rn � O Y D' Q DESIGN: LMS DRAWN: LVW CHECK: JGG JOB NO: 23266.10 DATE: 1 O/09/23 W 0 Z W (%� �O �aa �/ � _ Y ~ 0 � � Z W O N � � SHEET: RECEI Dec 14 2 2 CITI'�E. MO DS DEVELgPME SE VIC D P E O Z S1.1 /'Q LL U /'� LL '� V / C G COL PER PL PAVERS & SUBGRADE (B SLOPE AWAY F TYP DOUBLE --� TOP PLATE NOTE: 2x OR 3x BLOCKING ONLY STAGGER SHEATHING AS IF BLOCKED DIAPHRAGM a SHOWN. (IBC TABLE o � FOR 2x4 STUDS, PROVIDE SINGLE i =I 2306.3.1, CASE 1 OR 3) IS SPECIFIED w w ROW OF NAILS STAGGERED EA SIDE FRAMING MEMBERS W/ � z WITH 1 1/2" EDGE DISTANCE. FOR INTERMEDIATE SPACING PER PLAN � Q 2x6 STUDS, PROVIDE (2) ROWS OF SIMPSON A35 (ONLY FRAMING MEMBERS `" "-' 0 NAILS SPACED AT 2 1/2" W/ 1 1/2" REQUIRED AT EXTERIOR SHEATHING EDGE DISTANCE HEADERS GREATER PANEL, TYP THAN 6' SPAN) (3) TURNS TOP & BOT -___" 9" OC MAX SPACING BETWEEN (6) 0.131"� x 3" NAILS —_ —_ —_ ADJACENT NAILS IN A ROW CONTINUOUS PANEL EDGES � ------_ ADJACENT NAILS IN A TYPICAL STUDS -- ROW ARE TO BE I I DRIVEN FROM OPPOSITE SIDES, TYP BEAM OR HEADER PER PLAN AND NOTES I NAILING PER TYP I I I I � 0.131"� x 3" NAILS, TYP BUILT-UP STUD I I I � I � � l, 'I COLUMN DETAIL PANEL EDGES TYPICAL ROOF SHEATHING DETAIL SCALE: NTS (5) STUDS MAX TO AT HOEDOWNS: PROVIDE FULL HT RIPPLE STUDS PER PLAN BE USED FOR HOEDOWN CHORDS PER HD SCHED. AND COLUMN SCHEDULE OR BUILT-UP COLUMNS OTHERWISE: (1) 2x FULL HT STRUCTURAL NOTES TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = 1'-0" DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES SIMPSON A35 CLIP @ EA RAFTER SIMPSON LTP4 @ 24" OC CONT 2x8 LEDGER W/ (2) ROWS 16d NAILS @ 16" OC 2x6 @ 16" OC CEILING JOIST, ALIGNED VERTICALLY W/ RAFTERS SIMPSON LUS HANGER 2x6 LEDGER W/ (2) 16d NAILS @ 16" OC TYPICAL HEADER DETAIL SCALE: 1" = 1'-0" FULL DEPTH BLKG RIPPED TO MATCH SLOPE OF ROOF ROOF SHEATHING &NAILING PER ROOF FRAMING PLAN NOTES RIP ROOF RAFTER TO MATCH EXIST ROOF SLOPE EXISTING RAFTERS (FIELD VERIFY) EXIST 2x FULL DEPTH RIM (VERIFY/PROVIDE) 2x BLKG ALONG EXTENT OF LEDGER EXIST STUD WALL RAFTER SUPPORT DETAIL AT EXTERIOR WALL SCALE: 1" = 1'-0" SECTION SCALE: 1" = 1'-0" DIAPHRAGM BOUNDARY NAILING PER ROOF FRAMING PLAN NOTES RIP CEILING JOIST AS REQ'D FULL DEPTH BLKG RIPPED TO TO ALIGN BELOW RAFTER � MATCH SLOPE OF ROOF 2x6 VERT W/ (3) 16d NAILS INTO EA RAFTER &CEILING JOIST BEAM PER PLAN RAFTER SUPPORT DETAIL AT BEAM SCALE: 1" = 1'-0" 1 �i (8) #5 VERT BARS #3 SPIRAL @ 6" ROOF SHEATHING &NAILING PER ROOF FRAMING PLAN NOTES ROOF RAFTERS PER PLAN SIMPSON A35 CLIP @ 24" OC SIMPSON H2.5A TIE 2x6 @ 16" OC CEILING JOIST, ALIGNED VERTICALLY W/ RAFTERS SIMPSON LUS HANGER ENGINEERIIVC, 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 � G ' GAL g� of wAs.� �s 'S� tiw o. r'DG,� c-� tt7► o � �' O��C►�,�39553 ,�i ' ORAL ��`Y S`�IGNAL 10/ 09/ 2� J a F- F- Z O m � � W N (Y ~ C� � (n � W w 0 d m w � � rn Qo ° o Y (Y Q DESIGN: LMS DRAWN: LVW CHECK: JGG JOB NO: 23266.10 DATE: 1 O/09/23 C� N Z J �a a� �w �� O�DS �[ELOPIAEjI� S VDEn�/,k,TME W 0 � � >� > Q Z W � � � �aa ��� p _� I- O Y��i QO ��0 0� � � Z Z w O � 0 w � o O Z � I� w L� Q SHEET: S2.1 J