Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED ENG BLD PLN RESUB1 BLD2024-0089+Architectural_or_Building_Floor_Plans+3.5.2024_6.06.50_PM+4105699
LIFE SAFETY LEGEND EXISTING TRASH AND RECYCLING SERVICE ONCE PER WEEK rol ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. EXISTING PROPERTY LIN 1010.1.9.4 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side, provided: 2.1. The locking device is readily distinguishable as locked; 2.2. A readily visible and durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background; and 2.3. The use of the key -operated locking device is revocable by the building official for due cause. 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. V;z CONSTRUCTION TYPE VA OCCUPANCY GROUP B OCCUPANT LOAD 3" DIVISION 2S NOTED A 03/17/2024 DNLY - NO UOR WORK. SED TO TRASH LOCATION. IF ;UR, MAY BE Y OF EDMONDS AND TRASH HAULERS. NO WORK PERMITTED IN THE CITY RIGHT-OF-WAY. ALL STAGING, EQUIPMENT, MATERIALS, ETC. SHALL BE LOCATED ON PRIVATE PROPERTY. 14 Approved D F M akrl s i�,u Yt South County Fire Date: 03/07/2024 03-07-2024 RESUB PLAN REVIEW NOTES: APPROVED FIRE ALARM SYSTEM INSTALL IS NOT REQUIRED, NO CHANGE OF OCCUPANCY CLASSIFICATION. DFM BURT APPROVED BY PLANNING Mar 06 2024 — — TOTAL EXIT ACCESS TRAVEL DISTANCE d+ 4 AREA NOT IN CONTRACT - ADJACENT SUITES M BUSINESS USE 150 SF PER OCCUPANT MARSHALL DESIGN + MANAGEMENT CONCENTRATED BUSINESS USE 12400 SE 38TH #50766 50 SF PER OCCUPANT BELLEVUE, WA 98015 LIFE SAFETY GENERAL NOTES 1. OCCUPANT LOADS CALCULATED USING TABLE 1004.5 OF THE 2021 INTERNATIONAL BUILDING CODE. OCCUPANT LOAD FACTORS AS FOLLOWS: GROUP B: BUSINESS 850 GROSS 2. EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT SPECIAL KNOWLEDGE, EFFORT OR THE USE OF A SPECIAL KEY OR LATCH. 3. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING AN OCCUPANT LOAD OF 50 4. UNLATCHING FORCE OF PANIC HARDWARE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. 5. MEANS OF EGRESS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT CANDLE AT WALKING SURFACE LEVEL EXIT ILLUMINATION FIXTURES SHALL BE ON A SEPARATE NIGHT LIGHT CIRCUIT WITH BATTERY BACK-UP EXIT ILLUMINATION SHALL BE PROVIDED FOR NOT LESS THAN 90 MINUTES VIA STORAGE BATTERIES, OR ON -SITE GENERATOR. 6. CORRIDORS SHALL BE MAINTAINED WITH A MINIMUM CLEAR WIDTH OF 44" AND 7'-61, MINIMUM HEIGHT. 7. EXIT DOORS SHALL BE A MINIMUM OF 32" CLEAR WIDTH & MAXIMUM 48" WIDE LEAF. MINIMUM 6'-81, DOOR HEIGHT. 8. DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED CORRIDOR EXIT WIDTH BY MORE THAN HALF. 9. MAIN EXIT DOORS WITHOUT PANIC HARDWARE SHALL HAVE A SIGN WITH LETTERS ON A CONTRASTING BACKGROUND STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" CODE ANALYSIS CLIENT TM Ilk te p � TEASTEEPS, LLC 12918 MUKILTEO SPEEDWAY, SUTE C-23 #155 LYNNWOOD, WA 98087-5125 PROJECT TEASTEEPS, LLC CHANGE OF USE 660 EDMONDS WAY EDMONDS, WA 98020 OCCUPANT LOAD: 150 SF PER OCCUPANT FOR BUSINESS USE ISSUANCE 50 SF PER OCCUPANT FOR CONCENTRATED BUSINESS USE LOAD CALCULATION: 350 SF / 150 SF = 2.3 OCCUPANT LOAD 500 SF / 50 SF = 10 OCCUPANT LOAD ISSUE DATE: 01.17.2024 TOTAL AREA: 850 AREA DRAWN BY: RRO TOTAL OCCUPANT LOAD: 12 OCCUPANT LOAD CHECKED BY: MTM ON DUTY EMPLOYEES: 2 *EXISTING ADJACENT SUITES ARE BUSINESS USE REVISION LIST EXISTING REQUIRED PROVIDED NUMBER OF EXITS: <50 = 1 EXIT 1 NO. DATE DESCRIPTION BY GROUP B TABLE 1006.2.1 & 1 03.04.24 REVISION 1 RO TABLE1006.3.1 14 STALLS - NO CHANGE 1 ACCESSIBLE PARKING STALL - NO CHANGE BUILDING DATA ADDRESS: 660 EDMONDS WAY, EDMONDS, WA CONSTRUCTION TYPE: TYPE V-1 HOUR, NON-SPINKLERED OCCUPANCY: GROUP B (BUSINESS) BUSINESS DESCRIPTION: LOOSE LEAF TEA BUSINESS CONSULTATION ZONING: BN USE: BUSINESS CONSULTATION EXISTING USE: BUSINESS SEISMIC ZONE: 3 BLDG. AREA: BUILDING (TOTAL) 3,950 SQUARE FT SUITE B 850 SQUARE FT City Of Edmonds Building Department Work CHANGE OF USE ----------------------------------------------------- ------------- Address 660 EDMONDS WAY B ------------------------------------------------------- ------------------------- Owner TEASTEEPS -------------------- Approved Date 03� 11 2024 Building Official ff r ,& Permit Number BLD2024-0089 RESUB Mar 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE LIFE SAFETY PLAN Al M1 LIFE SAFETY PLAN Scale: 1 /8" = 1'-0" N ©Marshall Design + LLC FLOOR PLAN LEGEND DESIGNER 2 REFLECTED CEILING PLAN Scale. 1/4 = 1 -0 1 ESTROOM EXISTING LIGHTING WATTAGE CALCULATIONS FOUR LED TUBE 2' X 4' CEILING FIXTURES [14 WATTS PER TUBE X 4 = 56 WATTS PER FIXTURE X 9 FIXTURES = 504 WATTS] BACK HALLWAY CANLESS LED CEILING FIXTURE [15 WATTS X1 FIXTURE = 15 WATTS] REST ROOM WALL MOUNT FIXTURE WITH (4) 3.5 WATT LED BULBS [3.5 WATTS X 4 = 14 WATTS] 504 WATTS + 15 WATTS + 14 WATTS = 533 WATTS TOTAL LUMINARY USAGE 533/850SF = 0.63 LPD TABLE C405.4.2(1): ALLOWABLE 0.64 LPD EXISTING MOP SINK O> FIRE EXTINGUISHER EXISTING LAVATORI EXISTING SINK EXISTING COUNTERS 13.5"X60"X80.7" SHELVING SECURED TO WALL SITTING AREA I I (8 SEATS) COUNTER I I 13.5"X96"X96" SHELVING SECURELY ,> TETHERED TO WALL ON BOTH SIDES I � 13.5"X60"X80.7" ` SHELVING \ X SECURED TO % WALL J 3 FU�N��URE PLAN N Scale0" 0 EXISTING PARTITION TO REMAIN EXISTING DOOR RCP LEGEND 1�:�69�n[ey�lcll_��[y�ul►[ejlu�:l►uZel:11.7 I GENERAL NOTES 1. NO CHANGES TO PARTITIONS, LIGHTING, HVAC OR PLUMBING SYSTEMS INCLUDED IN PACKAGE. ALL EXISTING TO REMAIN. NO CHANGES TO EXISTING RESTROOM. 2. ALL EXISTING DOOR LEAFS ARE 36" WIDE. 3. SPACE IS HEATED WITH EXISTING ROOF TOP UNIT. 1010.1.9.4 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side, provided: 2.1. The locking device is readily distinguishable as locked; 2.2. A readily visible and durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING 1S OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background; and 2.3. The use of the key -operated locking device is revocable by the building official for due cause. 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. tAd+ M MARSHALL DESIGN + MANAGEMENT 12400 SE 38TH #50766 BELLEVUE, WA 98015 CLIENT TM lea.* Nteeps TEASTEEPS, LLC 12918 MUKILTEO SPEEDWAY, SUTE C-23 #155 LYNNWOOD, WA 98087-5125 PROJECT TEASTEEPS, LLC CHANGE OF USE ISSUEDATE: DRAWN BY: CHECKED BY 660 EDMONDS WAY EDMONDS, WA 98020 01.17.2024 RRO MTM NO. I DATE I DESCRIPTION 1 103.04.241 REVISION 1 A RESUB Mar 06 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE FLOOR PLAN/ RCP/ FURNITURE PLAN ©Marshall Design + LLC 2022