APPROVED BLD2021-1387+Plumbing_Plan+10.6.2021_2.26.27_PM+2448417GENERAL LEGEND SYMBOL DESCRIPTION ABBREVIATIONS ABBR DESCRIPTION ABBR DESCRIPTION PIPING LEGEND SYMBOL ABBR DESCRIPTION I SYMBOL ABBR DESCRIPTION A DETAIL SYMBOL: A = IDENTIFYING NUMBER B B = SHEET WHERE DETAIL IS SHOWN A DETAIL SYMBOL: A = IDENTIFYING NUMBER B C B = SHEET WHERE DETAIL IS TAKEN C = SHEET WHERE DETAIL IS SHOWN A SECTION SYMBOL: A = IDENTIFYING LETTER g B = SHEET WHERE SECTION IS SHOWN A SECTION SYMBOL: A = IDENTIFYING LETTER B C B = SHEET WHERE SECTION IS TAKEN C = SHEET WHERE SECTION IS SHOWN SECTION CUT LINE INDICATOR O1 KEYED REFERENCE NOTE OR SHEET NOTE e POINT OF CONNECTION (POC) SYMBOL P1-1 PLUMBING FIXTURE REFERENCE (REFER TO SCHEDULE) AHU-1 EQUIPMENT IDENTIFICATION (REFER TO SCHEDULES) OA MEDICAL GAS OUTLET IDENTIFICATION (REFER TO SCHEDULE) MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL MEDICAL GAS ALARM PANEL MOUNTED IN WALL MEDICAL GAS OUTLET REVISION CLOUD AND REVISION NUMBER XX BINARY (YES/NO) SENSING SWITCH (PIPE OR DUCT MOUNTED) XX BINARY (YES/NO) SENSING SWITCH (SURFACE MOUNTED) XX ANALOG SENSING DEVICE (PIPE OR DUCT MOUNTED) ANALOG SENSING DEVICE XX (SURFACE MOUNTED) QX ANALOG SENSING DEVICE (SURFACE MOUNTED) (APPROPRIATES SUBSCRIPT LETTER (X) INDICATES: A - ALARM PRESSURE SENSOR D - DIFFERENTIAL PRESSURE F - FLOW RATE H - HUMIDITY L - LOW LIMIT P - PRESSURE (STATIC) T - TEMPERATURE V - VELOCITY & VOLUME FLOW RATE Q Cn 00 0 0 N 0 N N N ABV ABOVE L LENGTH AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE AHU AIR HANDLING UNIT LBS POUNDS AL ACOUSTIC LINED LF LINEAR FOOT/FEET AP ACCESS PANEL LVG LEAVING APD AIR PRESSURE DROP LWG LOW WALL GRILLE ARCH ARCHITECT/ARCHITECTURAL LWR LOW WALL REGISTER ARV AUTOMATIC RELIEF VALVE or LWT LEAVING WATER TEMPERATURE ACID RESTISTANT VENT ARW ACID RESTISTANT WASTE MAX MAXIMUM MBH 1000 BRITISH THERMAL BDD BACKDRAFT DAMPER UNITS PER HOUR BFP BACKFLOW PREVENTER MCC MOTOR CONTROL CENTER BHP BRAKE HORSEPOWER MECH MECHANICAL BG BELOW GROUND MFR MANUFACTURER BJ BETWEEN JOISTS MIN MINIMUM BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS BTUH BRITISH THERMAL UNITS PER HOUR MTD MOUNTED MTG MOUNTING C CENTIGRADE CC COOLING COIL N/A NOT APPLICABLE CD CEILING DIFFUSER N/C NORMALLY CLOSED CFM CUBIC FEET PER MINUTE N/O NORMALLY OPEN CIS CEILING GRILLE NC NOISE CRITERIA CI CAST IRON NIC NOT IN CONTRACT CLG CEILING NTS NOT TO SCALE CO CLEANOUT CONC CONCRETE CIA OUTSIDE AIR CONN CONNECT or CONNECTION OBD OPPOSED BLADE DAMPER CONST CONSTRUCTION O/C ON CENTER CONT CONTINUATION OD OUTSIDE DIAMETER CR CONDENSATE RETURN OPNG OPENING DB DECIBLE or DRY BULB PCV PRESSURE CONTROL VALVE DDC DIRECT DIGITAL CONTROL PD PRESSURE DROP DIA DIAMETER PH or 0 PHASE DIM DIMENSION PLCS PLACES DN DOWN POC POINT OF CONNECTION DPR DAMPER POUA POINT OF USE ALARM DWG DRAWING PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH E-100 EXHAUST AIR PSIG POUNDS PER SQUARE INCH GAGE NUMBER INDICATES CFM QUANTITY EA EACH R-100 RETURN AIR EAT ENTERING AIR TEMPERATURE NUMBER INDICATES CFM QUANTITY EF EXHAUST FAN RA RETURN AIR EG EXHAUST GRILLE RAG RETURN AIR GRILLE ELEC ELECTRIC or ELECTRICAL REQD REQUIRED ELEV ELEVATION RPBP REDUCED PRESSURE BACKFLOW EMCS ENERGY MANAGEMENT CONTROL SYSTEM PREVENTOR ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE EXH EXHAUST EXST or (E) EXISTING S-100 SUPPLY AIR NUMBER INDICATES CFM QUANTITY F FAHRENHEIT SA SUPPLY AIR FA FACE AREA SF SUPPLY FAN FCO FLOOR CLEANOUT SHT SHEET FCU FAN COIL UNIT SIM SIMILAR FD FLOOR DRAIN SP STATIC PRESSURE FDPR FIRE DAMPER SQ SQUARE FFD FUNNEL FLOOR DRAIN SQ FT SQUARE FOOT/FEET FF FINAL FILTER SS STAINLESS STEEL FLR FLOOR STD STANDARD FPM FEET PER MINUTE FPS FEET PER SECOND THK THICK FT FOOT/FEET TP TRAP PRIMER or TEST PLUG FV FACE VELOCITY TYP TYPICAL TU TERMINAL UNIT GA GAGE or GAUGE GAL GALLON UBC UNIFORM BUILDING CODE GALV GALVANIZED UFC UNIFORM FIRE CODE GPH GALLONS PER HOUR UMC UNIFORM MECHANICAL CODE GPM GALLONS PER MINUTE UNO UNLESS OTHERWISE NOTED UPC UNIFORM PLUMBING CODE H HEIGHT UG UNDERGROUND HD HEAD UH UNIT HEATER HP HORSEPOWER HTG HEATING VA VALVE HVAC HEATING, VENTILATION AND VAC VACUUM AIR CONDITIONING VAV VARIABLE AIR VOLUME HWG HIGH WALL GRILLE VD VOLUME DAMPER HWR HIGH WALL REGISTER VEL VELOCITY HZ HERTZ VFD VARIABLE FREQUENCY DRIVE VTR VENT THRU ROOF W WASTE W/ WITH W/O WITHOUT WB WET BULB WCO WALL CLEANOUT WG WATER GAGE ISS WISE WASTE GAS EVACUATION WPD WATER PRESSURE DROP SD WT WEIGHT ARW ARV RD RD ORD ORD D RV ICW - -SCW - -FCW — �HW — - -KHW — - -KHWC — — - -LHW — - -LHWC — — — NPW IW DI DW CS CR CWS CWR RL RS HG HWS HWR FOS FOR G LPG LPS LPR MPS MPR HPS HPR PR MA LA MV N20 -N2 CO2 -V- -LV- WGE LIGHT LINEWORK INDICATES EXISTING PIPING OR EQUIPMENT INDICATES PIPING OR EQUIPMENT TO BE REMOVED SS SANITARY SEWER - OUTSIDE BUILDING AND BELOW GROUND SD STORM DRAIN - OUTSIDE BUILDING AND BELOW GROUND W WASTE (& SOIL) - ABOVE GROUND - INTERIOR W WASTE (& SOIL) - BELOW GROUND - INTERIOR V VENT ARW ACID RESISTANT WASTE ARV ACID RESISTANT VENT CW COLD WATER - DOMESTIC HW HOT WATER - DOMESTIC HWC HOT WATER CIRCULATING - DOMESTIC RD RAINWATER DRAINAGE - ABOVE GROUND RD RAINWATER DRAINAGE - BELOW GROUND ORD RAINWATER DRAINAGE OVERFLOW - ABOVE GROUND ORD RAINWATER DRAINAGE OVERFLOW - BELOW GROUND D DRAIN - INDIRECT RV RELIEF VALVE VENT PIPE SLOPE DIRECTION ICW INDUSTRIAL COLD WATER SCW SOFT COLD WATER FCW COLD WATER (FLUSHING SYSTEM) IHW INDUSTRIAL HOT WATER KHW KITCHEN HOT WATER KHWC KITCHEN HOT WATER CIRCULATING LHW LAUNDRY HOT WATER LHWC LAUNDRY HOT WATER CIRCULATING NPW NON -POTABLE WATER IW IRRIGATION WATER DI DEIONIZED WATER DW DISTILLED WATER CS CONDENSER WATER SUPPLY CR CONDENSER WATER RETURN CWS CHILLED WATER SUPPLY - COOLING CWR CHILLED WATER RETURN - COOLING RL LIQUID LINE - REFRIGERANT RS SUCTION LINE - REFRIGERANT HG HOT GAS LINE - REFRIGERANT HWS HOT WATER HEATING SUPPLY HWR HOT WATER HEATING RETURN FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN G NATURAL GAS LPG LIQUID PETROLEUM GAS LPS LOW PRESSURE STEAM SUPPLY LPR LOW PRESSURE STEAM CONDENSATE RETURN MPS(20) MEDIUM PRESSURE STEAM SUPPLY NUMBER IN PARENTHESIS INDICATES PSI MPR(20) MEDIUM PRESSURE STEAM CONDENSATE RETURN NUMBER IN PARENTHESIS INDICATES PSI HPS(100) HIGH PRESSURE STEAM SUPPLY NUMBER IN PARENTHESIS INDICATES PSI HPR(100) HIGH PRESSURE STEAM CONDENSATE RETURN NUMBER IN PARETHESIS INDICATES PSI PR STEAM CONDENSATE RETURN (PUMPED) ATV ATMOSPHERIC VENT MA COMPRESSED MEDICAL AIR LA COMPRESSED LABORATORY AIR MV MEDICAL VACUUM 02 OXYGEN N20 NITROUS OXIDE N2 NITROGEN CO2 CARBON DIOXIDE A COMPRESSED AIR V VACUUM LV LABORATORY VACUUM WGE WASTE GAS EVACUATION DRAWING INDEX DWG. NO. TITLE PO.1 COVER SHEET AND GENERAL INFO PO.2 GENERAL NOTES PO.3 SCHEDULES P1.1 UNDERGROUND PLUMBING PLAN P1.2 LEVEL 1 PLUMBING PLAN P1.3 LEVEL 2 PLUMBING PLAN P1.4 PLUMBING ROOF PLAN P2.1 RISER DIAGRAMS P4.1 DETAILS P4.2 DETAILS CAP PIPE END CAP PIPE TURNING DOWN OR AWAY PIPE TURNING UP OR TOWARD PIPE TURNING DOWN OR AWAY (TEE) REDUCER (NOT TYPICALLY SHOWN) PIPE CONNECTION PIPE ANCHOR (NOT ALWAYS SHOWN, SEE SPECIFICATIONS) PIPE ALIGNMENT GUIDES (NOT ALWAYS SHOWN, SEE SPECIFICATIONS) HB HOSE BIBB WH/NFWH WALL HYDRANT or NON -FREEZE WALL HYDRANT CO/WCO CLEANOUT or WALL CLEANOUT FCO/SCO FLUSH CLEANOUT or SURFACE CLEANOUT FDC FIRE DEPARTMENT CONNECTION FIRE SPRINKLER ALARM GONG AD AREA DRAIN FD or FFD FLOOR DRAIN or FUNNEL FLOOR DRAIN FS FLOOR SINK OD OVERFLOW DRAIN RD ROOF DRAIN SHUTOFF VALVE (AS SPECIFIED FOR PIPING SYSTEM) BV BALL VALVE CKV CHECK VALVE BFV BUTTERFLY VALVE BFV BUTTERFLY VALVE W/ MEMORY STOP BAL VA BALANCING VALVE BSV COMBINATION BALANCING/SHUTOFF VALVE ACV 2-WAY MODULATING CONTROL VALVE W/ ACTUATOR ACV 3-WAY MODULATING CONTROL VALVE W/ ACTUATOR 2-POSITION CONTROL VALVE PRV PRESSURE REDUCING VALVE RV RELIEF VALVE FMS FLOW MEASUREMENT STATION STR Y-TYPE STRAINER GLV GLOBE VALVE OSY VA OUTSIDE SCREW AND YOKE VALVE EXP VA EXPANSION VALVE FCV FLOW CONTROL VALVE UNION FLANGES THREADED DRAIN PLUG MALE (GARDEN) HOSE CONNECTION WITH CAP TP TEST PLUG SHOCK ARRESTOR TH or TI THERMOMETER (TEMPERATURE INDICATOR) B STR BASKET STRAINER PI PRESSURE INDICATOR MV AUTOMATIC AIR VENT MANUAL AIR VENT PUMP (DIAGRAM) FLEXIBLE CONNECTOR INDICATES ASSEMBLY OF PIPING COMPONENTS (AS NOTED OR DIAGRAMED) City Of Edmonds Building Department Work PLUMBING Address 471 ADMIRAL WAY ------------------------- Owner PORT OF EDMONDS ---------------------- --------------------------------------- Approved Date 1/5/2021 1 ---------------------------------- Building Official W. X 49111[t Permit Number BLD2021-1387 APPROVED BY CROSS CONNECTION 11/30/21 AND PRE-TREATMENT 12/7/2021 NJ I iTl ACKSON I MAID RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM AFRFFMAN I N E E 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 z O o CN 0 LLI W J Q L Q O � U) Q 0 Q O W J M � U M W v) 0 z CD z U) CN C:)�Dw>_00 OJ� LLJ � 0 �:Q L.L mO�� O U) �z��0 Q0 0 Q 0� W ,� 2 0 W J z O ~ a m D U W LU o � w a o z W N Q o p 10/5/21 PROJECT NO.: 210887 PROJECT Mi ON DRAWN BY: CEI CHECKED BY: ON COVER SHEET AND GENERAL INFO POO 1 JACKSON I MAIN ARCHITECTURE P.S. © 2021 GENERAL M ECH NOTES GENERAL PLUMBING NOTES 1. CONTRACTOR SHALL SECURE, MAINTAIN, AND PAY FOR ALL REQUIRED PERMITS, LICENSES, AND INSPECTIONS FOR DURATION OF WORK UNLESS DIRECTED OTHERWISE. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, WASHINGTON STATE ENERGY CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, UNIFORM PLUMBING CODE, AND GOVERNING STATE AND LOCAL CODES AND ORDINANCES. 3.THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 4. ALL WORK SHALL COMPLY WITH THE OWNER'S REQUIREMENTS. 5. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE COMPLETE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DESIGN CHANGES OR IMPACTS THAT THE PROPOSED EQUIPMENT SUBSTITUTION HAS ON OTHER DISCIPLINES. ANY ADDITIONAL ELECTRICAL, STRUCTURAL, MECHANICAL, OR ARCHITECTURAL REQUIREMENTS SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO THE OWNER. 6. REFER TO PROJECT MANUAL (SPECIFICATIONS) FOR ADDITIONAL REQUIREMENTS. PLANS AND SPECIFICATIONS SHALL BE TAKEN TOGETHER. PROVIDE ALL WORK CALLED FOR IN EITHER. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND PLANS THE MORE STRINGENT SHALL APPLY. 7. MATERIALS OR EQUIPMENT SPECIFIED TO BE "FURNISHED BY OTHERS" SHALL BE FURNISHED BY THE GENERAL CONTRACTOR AND PROCURED FROM SOURCES SPECIFIED BY THE CONTRACT DOCUMENTS. 8. ALL EQUIPMENT AND MATERIAL ON THE JOB SITE PRIOR TO INSTALLATION SHALL BE COVERED AND PROTECTED FROM DIRT, DUST, AND DAMAGE. 9. PROVIDE ALL DEMOLITION WORK CALLED FOR OR REQUIRED BY THE INSTALLATION. REMOVE ALL EXISTING EQUIPMENT AND MATERIALS NOT REUSED UNLESS SPECIFIED OTHERWISE BY THE OWNER'S REP. 10. VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE FINAL EQUIPMENT LOCATIONS W/ GENERAL CONTRACTOR AND OTHER TRADES TO ALLOW FOR REQUIRED MECHANICAL EQUIPMENT CLEARANCES. 11. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 12. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF INSTALLATION STANDARDS AND CONSTRUCTION CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SHOP FABRICATION AND/OR FIELD INSTALLATION. DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONSTRUCTION DRAWINGS SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER. WORK DONE WITHOUT THE ENGINEERS APPROVAL IS THE RESPONSIBILITY OF THE CONTRACTOR. 13. ALL MECHANICAL EQUIPMENT, MATERIALS, AND INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR. ALL EQUIPMENT SHALL BE COMPLETE, INSTALLED, AND FULLY FUNCTIONAL PRIOR TO FINAL ACCEPTANCE OF THE WORK. 14. INSTALL ALL EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS AND REQUIREMENTS. ANY CONFLICTS BETWEEN THE MANUFACTURERS DOCUMENTATION AND THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 15. PROVIDE SEISMIC RESTRAINT OF MECHANICAL SYSTEMS AND EQUIPMENT AS REQUIRED BY ASCE-7 AND INTERNATIONAL BUILDING CODE AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION. 16. DO NOT ALLOW ANY WORK TO BE COVERED UP OR ENCLOSED UNTIL INSPECTED, TESTED AND APPROVED BY OWNER'S REPRESENTATIVE OR AUTHORITY HAVING JURISDICTION. 17. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. Q Cn 00 0 0 N O N N N ro 1. PLUMBING CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO CONSTRUCT A COMPLETE, OPERATIONAL PLUMBING SYSTEM FOR THE ENTIRE PROJECT AS SHOWN ON THESE DRAWINGS, INCLUDING ALL NECESSARY FEES AND PERMITS. 2. DO NOT SCALE DRAWINGS. INSTALL SYSTEMS BASED ON ACTUAL FIELD MEASUREMENTS. 3. PIPING AND EQUIPMENT ANCHORAGE: PROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SPECIFICATIONS AND THE INTERNATIONAL BUILDING CODE. 4. PIPE SIZES: WHERE A SECTION OF PIPE BETWEEN TAKEOFFS DOES NOT HAVE A SIZE INDICATED, IT SHALL BE SAME SIZE AS SECTION UPSTREAM. IN GENERAL, AS VOLUME FLOW RATE DECREASES, PIPE SIZE SHALL REMAIN LARGE UNTIL A SMALLER SIZE IS INDICATED. NOTE THAT SOME PIPE SIZES ARE INDICATED ON ASSOCIATED DEVICE SCHEDULE. 5. HANDICAP FIXTURES: PLUMBING FIXTURES AND TRIM IN HANDICAP ACCESSIBLE AREAS SHALL COMPLY WITH ALL ADA STANDARDS AND REQUIREMENTS AS WELL AS STATE AND LOCAL CODES. 6. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF WALLS, FLOORS, AND CEILINGS. 7. COORDINATE EXACT LOCATION OF STUB -UPS TO PLUMBING FIXTURES WITH ARCHITECTURAL PLANS. PROVIDE MEANS TO CONNECT TO ABOVE GROUND PIPING & INSTALLATION OF DRAINS. 8. COORDINATE EXACT LOCATION OF UTILITY SERVICES WITH THE LOCAL UTILITY SUPPLIERS AND EXISTING PLANS. CONTRACTOR TO FIELD VERIFY. 9. FIELD VERIFY ALL EXISTING CONDITIONS AND LOCATIONS OF STUB -INS PRIOR TO INSTALLATION. 10. PLUMBING CONTRACTOR SHALL NOTIFY ENGINEER OF ANY PROPOSED CHANGES TO DESIGN PRIOR TO TAKING ACTION. 11. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, VALVES, AND OTHER DEVICES AND ACCESSORIES REQUIRED FOR A COMPLETE, WORKABLE INSTALLATION. 12. PENETRATIONS THRU FIRE RATED ASSEMBLIES SHALL COMPLY WITH THE LATEST ACCEPTED VERSION OF THE IBC. COORDINATE WITH ARCHITECTURAL PLANS. 13. PROVIDE PROPER PROVISIONS FOR EXPANSION OR MOVEMENT OF ALL PIPING. 14. SUPPORT HORIZONTAL LINES OF COPPER TUBING WITH HANGERS SPACED NOT MORE THAN 6-FEET, CENTER TO CENTER FOR ALL PIPE SIZES. ALL PIPES SHALL BE SUPPORTED AT ELBOWS, BRANCHES, AND RISERS. 15. SUPPORT HORIZONTAL CAST IRON SOIL PIPE WITH HANGER, OR PIER, TWO FOR EACH 5-FOOT PIPE LENGTH. LOCATE SUPPORT CLOSE TO JOINTS EXCEPT, PIPE EXCEEDING 5-FEET IN LENGTH SHALL BE SUPPORTED AT NO MORE THAN 5-FOOT INTERVALS. SUPPORTS SHALL BE LOCATED ON BOTH SIDES OF ALL JOINTS AND WITHIN 6" OF THE JOINTS. 16. NO DOMESTIC HOT WATER, HOT WATER RECIRCULATING, OR COLD WATER PIPING WILL BE PERMITTED WITHIN EXTERIOR WALLS. 17. PROVIDE WATER HAMMER ARRESTORS (SHOCK ABSORBERS) AT ALL PIPE LOCATIONS WHERE VALVE CLOSURES (SUCH AS FLUSH VALVES) MAY CAUSE WATER HAMMER OR RESULT IN EXCESSIVE PIPE VIBRATION OR MOVEMENT. 18. CLEANOUTS: PLUMBING CLEANOUT LOCATIONS ARE NOT ALWAYS ESTABLISHED ON THE PLUMBING PLANS IN ORDER TO GIVE THE PLUMBER FLEXIBILITY TO LOCATE PLUMBING CLEANOUTS IN THE MOST ACCESSIBLE AREAS. AS A MINIMUM, PROVIDE CLEANOUTS AS REQUIRED BY THE UNIFORM PLUMBING CODE. CLEANOUTS THAT MUST BE INSTALLED IN PIPES THAT ARE DIFFICULT TO ACCESS SHALL BE EITHER WALL OR FLOOR CLEANOUTS SERVICED FROM THE FLOOR ABOVE. FLOOR CLEANOUTS SHALL BE LOCATED SO AS TO BE SERVICED FROM CORRIDORS, TOILET OR JANITOR ROOMS WHEREVER POSSIBLE. 19. TRAP PRIMERS AND ARRESTORS: TRAP PRIMER ACTUATORS AND WATER HAMMER ARRESTORS SHALL BE LOCATED TO BE ACCESSIBLE EITHER THROUGH ACCESSIBLE CEILING OR WALL ACCESS DOORS. REFER TO SPECIFICATION FOR WHERE ARRESTORS NEED TO BE LOCATED. 20. TRAP PRIMER LINE SIZE TO EACH FLOOR DRAIN OR FUNNEL DRAIN SHALL BE 1/2" DIAMETER. 21. DRAINAGE PIPING SHALL BE PROTECTED FROM CONCRETE USING 10-MIL PLUMBERS TAPE. 22. SANITARY PIPING 2" AND BELOW SHALL BE SLOPED AT A MINIMUM OF 1/4' PER FOOT AND PIPING 4' AND ABOVE SHALL BE SLOPED AT A MINIMUM OF 1 /8' PER FOOT, UNLESS OTHERWISE NOTED. 23. DOMESTIC COLD WATER PIPING AND FITTINGS SHALL BE SEAMLESS TYPE "L' COPPER WITH 95-5 SOLDER. SOLDER CONTAINING LEAD IS NOT ACCEPTABLE. 24. EFFICIENT WATER HEATER SUPPLY PIPING: HOT WATER SUPPLY PIPING SHALL BE PLUMBED IN COMPLIANCE WITH C404.3 IN CURRENT WSEC. 25. PROVIDE HEAT TRAPS ON SUPPLY AND DISCHARGE PIPING FOR ALL POINT -OF -USE WATER HEATERS PER CURRENT WSEC C404.4. 26. PLUMBING CONTRACTOR SHALL PRESSURE TEST PIPING PRIOR TO COVERING AND SUBMIT TEST REPORT TO ENGINEER. 27. COMMISIONING: HOT WATER SUPPLY SYSTEM SHALL BE COMMISSIONED IN ACCORDANCE WITH C408.4 IN CURRENT WSEC. iT/ ACKSON I MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM AFRFFMAN ll€EEIi 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships n 0 z 0 G 0 Uj U_ 0 IN- 0 n 0 z 0 G 0 Uj L.L 0 N� 0 RECEIVED Oct 14 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V z_ 0 D co z G 0 Q N Q00 warn J >Q 0 Q U) Q 0 z<0 LUQ2 U cM Lij U) O LJJ >- 00 Q 0 0 J a 0 0 U2Lij z -) 0 01- L1J J z O ~ a m U) U 1- H W w � o � w a O z H N_ LO Q O � 10/5/21 PROJECT NO.: 210887 PROJECT Mi ON DRAWN BY: CEI CHECKED BY: ON GENERAL NOTES JACKSON I MAIN ARCHITECTURE P.S. © 2021 a Cn 00 0 0 N 0 N N N PLUMBING FIXTURE SCHEDULE SERVICE PIPE SIZE BASIS OF DESIGN MARK ITEM LOCATION FLOW RATE REMARKS NOTES WASTE VENT C.W. H.W. MANUFACTURER MODEL LAV-1 LAVATORY -WALL HUNG - 2 1-1/2 - - KOHLER K-2007 VITREOUS CHINA, 21-1/4" X 18-1/8" OVERALL DIMENSIONS, SINGLE FAUCET HOLE, ADA COMPLIANT. PROVIDE WITH 1, A, as CONCEALED ARM CARRIER. L1 RESTROOMS FAUCET 0.5 GPM - - 1/2 1/2 KOHLER K-13462-CP SENSOR, SINGLE HOLE MOUNTING, MAX FLOW RATE 0.5 GPM, VANDAL -RESISTANT AERATOR. PROVIDE WITH AC POWER SUPPLY. LAV-2 LAVATORY-UNDERMOUNT - 2 1-1/2 - - KOHLER K-20000 VITREOUS CHINA, RECTANGULAR BASIN, OVERFLOW DRAIN, 20-1/4" X 15-11/16" X 7-5/16" OVERALL 1, A, °° DIMENSIONS, 17-5/8" X 13-1/8" X 5-5/16" BOWL DIMENSIONS. NO FACUET HOLES. ADA COMPLIANT. L2 RESTROOMS FAUCET 0.5 GPM - - 1/2 1/2 SIGNATURE CASIMIR SINGLE -HOLE BATHROOM FAUCET, HEIGHT 12-1/2", SPOUT REACH 8", MANUAL 4-14" HANDLE, MAX FLOW 1.2 HARDWARE GPM. MAX COUNTERTOP THICKNESS 1-3/8". 1/2" IPS CONNECTIONS. WC-1 WATER CLOSET -FLOOR MOUNT - 4 2 - - SLOAN ST-2029 FLOOR MOUNTED ,SIPHON JET, ELONGATED BOWL, 1.6 GPF, REAR OUTLET, VITREOUS CHINA, 1-1/2" TOP SPUD. ADA COMPLIANT. CENTERLINE OF OUTLET 4-1/4" AFF. FLUSHOMETER RESTROOMS 1.1/1.6 GPF - - 1-1/4 - SLOAN WES 111 EXPOSED MANUAL FLUSHOMETER, DUAL FLUSH, ADA COMPLIANT. LOCATE LEVER ON THE OPEN SIDE OF THE WATER CLOSET, VARIES BY LOCATION, REFER TO PLANS. SEAT - - - - - BEMIS 1955SSCT OPEN FRONT, LESS COVER, ELONGATED, PLASTIC, SELF-SUSTAINING CHECK HINGES. UR-1 URINAL -WALL HUNG 2 2 - - KOHLER DEXTER K-5016-ET SIPHON JET, TOP SPUD, 14-1/2" EXTENDED RIM, VITREOUS CHINA, ADA COMPLIANT. INCLUDES HANGERS. RESTROOMS FLUSHOMETER 0.5 GPF - - 3/4 - KOHLER K-10958-SV TOUCHLESS, INFRARED SENSOR, DC BATTERY POWERED, FOR 3/4" SPUD COUPLING CONNECTION 304 STAINLESS STEEL, SINGLE BOWL, UNDERMOUNT, 25" X 22" X 6" OVERALL DIMENSIONS, REAR CENTER DRAIN SK-1 SINK -SINGLE BOWL UNDERMOUNT - 2 2 - - ELKAY ECTSRAD25226TBG LOCATION, 3 HOLE DRILLING, 4 ON CENTERS. C BREAK ROOM FAUCET 0.5 GPM - - 1/2 1/2 CHICAGO FACUETS 431-ABCP DECK MOUNTED, 8" FIXED CENTERS, SINGLE LEVER, USER ADJUSTABLE TEMPERATURE CONTROL MIXER. MS-1 MOP SINK - 3 2 - - MUSTEE MODEL 63M ONE-PIECE MOLDED, DURASTONE FIBERGLASS, DIMENSIONS 24" X 24" X 10" , WHITE FINISH, INTEGRAL MOLDED -IN DRAIN. PROVIDE WITH MUSTEE HOSE AND HOSE HOLDER MODEL NO. 65.700. CUSTODIAL FAUCET 3.0 GPM - - 3/4 3/4 CHICAGO FAUCETS 897-RCF WALL MOUNTED 8" BODY, ADJUSTABLE ARMS, HOT AND COLD WATER, VANDAL PROOF LEVER HANDLES, CERAMIC 1/4 TURN CARTRDIGES. DF-1 DRINKING FOUNTAIN W/BOTTLE FILLING STATION CORRIDOR - 2 2 1/2 - ELKAY EMABFTLDDWSLK BOTTLE FILLING STATION, BI-LEVEL ADA COOLER, NON -FILTERED, NON -REFRIGERATED, WALL MOUNT, 36-1/4" X 18-5/8" X 46-1/4", 115V/60HZ, 2 FLA, 15 WATTS. HB-1 EXTERIOR HOSE BIBB SEE PLANS - - - 3/4 - WOODFORD MODEL B65 WOODFORD WALL HYDRANT BIBB. ANTI -SIPHON FREEZELESS. CONCEALED WITH LOCKABLE COVER. WB-1 WALL BOX- COLD WATER ONLY BREAKROOM - - - 1/2" - OATEY 39150 1/4 TURN BRASS HAMMER BALL VALVE LOW LEAD, 1/2" ASTM F1960 PEX TP-1 ELECTRONIC TRAP PRIMER TRASH ROOM - - - 3/4 - PPP PT-4 PRIME -TIME ELECTRONIC TRAP PRIMING ASSEMBLY FOR WASTE ROOM FLOOR DRAIN. FD-1 FLOOR DRAIN SEE PLANS - PLANS SEE PLANS - - JAY R SMITH 2O05-A ROUND NICKEL BRONZE TOP. PROVIDE TRAP PRIMER CONNECTION WHERE CONNECTED TO SANITARY SYSTEM. 4 FFD-1 FUNNEL FLOOR DRAIN SEE PLANS - PLANS SEE PLANS - - ZURN ZN-415E CAST-IRON BODY, FLASHING COLLAR WITH ADJUSTABLE STRAINER, BAR GRATE, AND CAST IRON FUNNEL 4 FCO-1 FLOOR CLEANOUT SEE PLANS - PLANS - - - JAY R SMITH 4021S FINISHED FLOOR CLEANOUT WITH ADJUSTABLE NICKEL BRONZE TOP, BRONZE PLUG WITH GASKET SEAL. NOTES: STRAINER TYPES: TRAPS: 1. COORDINATE MOUNTING HEIGHT W/ ARCH'L INTERIOR ELEVATIONS. A. LAVATORY GRID TYPE (ADA) "DEARBORN" 760W aa. 1-1/4"x1-1/2" 17GA., "MCGUIRE" C8872 2. LOCATE FLUSH VALVE HANDLE ON WIDE SIDE OF FIXTURE FOR ADA COMPLIANCE. B. LAVATORY GRID TYPE,-DEARBORN" 760 1 bb. 1-1/2"x1-1/2" 17GA., "MCGUIRE" C8912 3. TRAP PRIIMER CONNECTION C. SINK GRID TYPE, "ELKAY" LK-18 cc. 2"x2" 4. FLOOR DRAIN SIZES VARY, REFER TO PLANS dd. 3"0" DOMESTIC WATER HEATER SCHEDULE CAPACITY RECOVERY EWT LWT ELECTRICAL BASIS OF DESIGN MARK SERVICE TYPE REMARKS GAL GPH F F KW V PH FLA MAKE MODEL WEIGHT LBS WH-1 DOMESTIC HOT WATER ELECTRIC 50 25 40 120 6 208 3 16.7 AO SMITH DRE-52-6 599 1-6 NOTES: 1. TANK TYPE WATER HEATER SET AT 120 DEG F. 2. PROVIDE EXPANSION TANK SUITABLE FOR DOMESTIC WATER USE. SEE EXPANSION TANK SCHEDULE 3. GLASS LINED TANK RATED FOR 125 PSIG WORKING PRESSURE. 4. COMPLIES WITH THE STANDBY LOSS REQUIREMENTS OF THE US DEPARTMENT OF ENERGY AND CURRENT EDITION OF ASHRAE/IES 90.1. 5. 3-YEAR TANK WARRANTY. MOUNT WATER HEATER OVER STEEL PLATFORM OR R-10 INCOMPRESSIBLE INSULATED SURFACE. 6. USE QS 120 HOLD RITE STRUT SEISMIC STRAP TO SECURE WATER HEATER. INSTALL PER MANUFACTURER 1/0 MANUAL. BACKFLOW PREVENTER SCHEDULE MARK LOCATION DESCRIPTION SERVICE SIZE DESIGN FULL PD 0 FULL BASIS OF DESIGN REMARKS MFR. MODEL (IN.) FLOW (GPM) FLOW (PSI) RPBP-1 110 MECH ROOM REDUCED PRESSURE ZONE DOMESTIC COLD 2-1/2 74 12 WATTS LF009 1,2,3,4,5,E BACKFLOW PREVENTER WATER NOTES: 1- PROVIDE WITH WATTS AIR GAP SERIES 909AG. 3- LEAD FREE, FOR HEALTH HAZARD APPLICATIONS. 4- PIPE WASTE DRAIN TO FUNNEL FLOOR DRAIN PER PLANS. PIPE SIZE SAME AS CONNECTION. 5- INSTALL IN ACCESSIBLE LOCATION ONE TO FIVE FEET ABOVE FINISHED FLOOR LEVEL. 6- SUPPORT ADEQUATELY TO PREVENT FROM DAMAGE. PLUMBING FIXTURE UNIT CALC Room Name or Level Fixture Type Qty. Private or Public Building CW Service Water Distribution Piping Sanitary WSFU Each Total WSFU CW or HW Fixture CW Branch WFU Each HW Branch WFU Each CW Dist. WFU Total HW Dist. WFU Total DFU Each Total DFU Level 1 WC - flush valve up to 1.6 GPF 1 Public 5 5 CW 5 - 5 - 4 4 Urinal - flush valve 1.0 GPF 1 Public 4 4 CW 4 - 4 - 2 2 Lav 2 Public 1 2 CW&HW 0.75 0.75 1.5 1.5 1 2 Hose Bibb 1 Private 2.5 2.5 CW 2.5 - 2.5 - 0 0 Hose Bibb -Ea. Add. 3 Private 1 3 CW 1 - 3 - 0 0 Floor Drain 4 Private - - - - - - - 2 8 Allowance for Future Retail Space 61 63 Level 2 WC - flush valve up to 1.6 GPF 2 Public 5 10 CW 5 - 10 - 4 8 Urinal - flush valve 1.0 GPF 1 Public 4 4 CW 4 - 4 - 2 2 Lav 2 Public 1 2 CW&HW 0.75 0.75 1.5 1.5 1 1 2 Drinking Fountain 2 Public 0.5 1 CW 0.5 - 1 - 0.5 1 Mop Sink 1 Public 3 3 CW&HW 2.25 2.25 2.25 2.25 3 3 Sink - Kitchen, domestic 1 Private 1.5 1.5 CW&HW 1.125 1.125 1.125 1.125 2 2 Floor Drain 1 Private - - - - - - - 2 2 Dishwasher Res. 1 Private 1.5 1.5 HW - 1.5 - 1.5 0 0 Wall box - Ice Maker 1 Private 1 1 CW 1 - 1 - 0 0 Hose Bibb -Ea. Add. 1 Private 1 1 CW 1 - 1 - 0 0 Allowance for Leasable Office 1 1 23 1 1 1 1 1 19 Total WSFU: 126 Total DFU: 118 GPM: 74 Pipe Size: 4" Bldg CW Service Pipe Size: EXPANSION TANK SCHEDULE TAG LOCATION SERVICE TYPE VOLUME (GAL.) ACCEPTANCE (GAL) SIZE Hxre (IN.) WEIGHT EMPTY (LBS.) BASIS OF DESIGN REMARKS RM. NAME MFR MODEL ET-1 MECH ROOM DOMESTIC HW DIAPHRAM 2.0 0.45 13x8 5 AMTROL ST-5 1 NOTES: 1 PRE -CHARGE 2 PSI BELOW NORMAL OPERATING WATER PRESSURE OF 60 PSI. PUMP SCHEDULE CAPACITY MOTOR PUMP SUCTION POWER TAG SERVICE LOCATION / DISCHARGE BASIS OF DESIGN WEIGHT (LBS) REMARKS GPM FT HD HP RPM VOLTS PH VFD? TYPE SIZE CP-1 HOT WATER RECIRC MECH ROOM 3 15 1/12 - 120 1 NO N 3/4" B&G ECOCIRC XL 20-35 22 1,2 NOTES: 1. LEAD-FREE STAINLESS STEEL PUMP FOR POTABLE WATER USE. HIGH EFFICIENCY ECM. 30% GLASS FILLED NORYL IMPELLER, STAINLESS STEEL SHAFT & SLEEVE. STARTER PROVIDED BY EC. CONTROL BY PC, PROVIDE WITH AQUASTAT AND TIMER. 2. PROVIDE BALANCING VALVE. SEE WATER HEATER DETAIL. iT/ ACKSON I MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM Hfi �QFFMAN ll€EEIi 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 Z 0 0 2 > � 0 LLI Q L U L.L 0 U' Q L.L Q O w J M U cY) W vJ 0 Z CD 0 z v, �Ow>-00 o � L LJ J 0 < Q L.LmO�� 0 . Z ��c) U 0 L.L -)Q0 00 Q 0- W J Z 0~ a m �D U o7 I_ W o � w a O Z H N LO Q o p 10/5/21 PROJECT NO.: 210887 PROJECT Mi ON DRAWN BY: CEI CHECKED BY: ON SCHEDULES JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: 4"FIRE WATER SERVICE. SEE CIVIL FOR CONTINUATION, Q Cn 00 0 0 N O N N N CO T T3 T 5 1 2-1/2" DOMESTIC WATER 4" SANITARY DRAIN. SERVICE. SEE CIVIL FOR IE=10.0' SEE CIVIL FOR TO GREASE INTERCEPTOR (TBD). CONTINUATION. CONTINUATION. OWNER TO PROVIDE DIRECTION 1 ON LOCATION OF GREASE INTERCEPTOR FOR POTENTIAL FUTURE KITCHEN TENANT. TO PROVIDE DIRECTION ',ATION AND EXTENT OF WASTE PIPING TO BE ED AS PART OF CORE TELL. !LEV. HINE R 107 UNDERGROUND PLUMBING PLAN SCALE: 3/16" = 1'-0" 4"W up URIN, Il 4"W UP TO FCO An LOBBY UNISEX RIR 2"W UP 2"W UP CUSTODIAL STORAGE 106 2"W UP 4"W UP TO FCO 2"V U 4"W OF - — - ----(:c ) — — — ----(:A) KEYNOTES: D PROVIDE BACKWATER VALVE IN VAULT WITH ACCESS LID FOR MAINTENANCE. UPSTREAM MANHOLE ELEVATION OF 15.43' IS ABOVE THE LEVEL 1 FFE OF 14.00'. A BACKWATER VALVE IS REQUIRED FOR THE LEVEL 1 SANITARY WASTE PER THE UPC. NJ I ivl ACKSON I MAIf R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM AF!RFFMAN ll€EEIi 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY OF E DEVELOPMENTT SERVICES DEPARTMENT 0 z O _C) CN 0 w QW � 0-)W �JQ LL OQ� O 0 U) Q � r) ~ ZOO Q O w J M 2 U cY) w C) 0 z(D O Z U) O �Dw> 00 OJ��Q w 0 LL mO�� O z �ry U2i0 U) Lu � 0 Q z 0 00�� 0- Q w�w 2 J z O ~ a m D U Cn ~ CO W 0 � W o� z LU N Q � O 0 - 10/5/21 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON UNDERGROUND PLUMBING PLAN Pi mi JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: 1. ROUTE HOT WATER MAIN WITHIN 2FT OF PUBLIC LAVS PER WSEC MAXIMUM ALLOWABLE PIPE LENGTH METHOD. T T3 T 5 1 FCO (2)2"V ►-. COMMERCIAL RETAIL 101 1-1/2" CW UP 1 "HW UP 3 UP 3"V CA?FFWO 1 1 FOR FUTURE BOv� RPBP-1 HB-1 I FFE=14.00' RETAIL I I 101 i�''1�/2„CW � 3"V CAPPED FOR FUTURE FCO-1 CAPPED FOR 3"V UP FUTURE 0 ►Cy'� I I i I I I I E . I I IF I I I I I I I I I I I I I I I I I I I DOUBLE HT. MAINTENANCE I DOUBLE HT. BAY (2) MAINTENANCE 102 BAY (2) I 102 I OPEN PTO STRUCTURE ABOVE I I I I I 3/4"CW UP. LOCATE I SHUTTOFF VALVE 4' I ABOVE FLOOR I I I I I HB-1 I I Q Cn 00 0 0 N 0 N N N C .4 0 FCO-1 o o 2"V 2 hA' EN T - STU 2"W UP OVE I OPEN TO OPEN TO _ STRUCTURE ABOVE STRUCTURE ABOVE _ n s; " E V.--------------- Er- C� 0 F I PART AGE MACH E RM. _ C 1 1 1 1 I 4"W UP 4 ELEV. �_ 2'V UP " P PARTS 6i % TE MTiQCHINE RM. 4„W DN I I OVIDE 6 10 3�(4"CW UMBIN —------i----------_ ---- — HB-1 2"W UP 1 �1 .,2"CW= , UNISEX R.R. _ 5 `I 104 3"W UP 2/ .lip= : - _ _ , • „ :I -2 U P j ,SINGLE HT: 10 MAIN,TENdNCI=' ti SINGLE HT..'-'-,` _ MAINT�NAIIII 2"W OPEN TQ s1 Ri1CTUR A$O�E;, _ CUSTODIAL UP STORAGE 4"W FOR y' CUSTODIAL 106 1 Cf�- :FUTURE` QFF[C� : " STORAGE , INSTALL SHUTOFF t` ' ; 8Pie►GE'_ ABOVE.." _'VALVE_' 4' �4BO.V-E' ; . _ I `, ,} . FLOOR ; - of - LEVEL 1 PLUMBING PLAN SCALE: 3/16" = 1'-0" KEYNOTES: D PROVIDE 2-1/2" PRV SET TO 60 PSI. LEAD FREE CONSTRUCTION AND SUITABLE FOR DOMESTIC WATER APPLICATIONS. STATIC PRESSURE IS 130 PSI PER THE WATER AGENCY CERTIFICATION IN THE CITY OF EDMONDS PLANNING DIVISION REPORT. D PROVIDE A DRIP PAN UNDER WASTE PIPING IN THE ELECTRICAL ROOM. D PROVIDE BALANCING VALVE, CHECK VALVE, AND ISOLATION VALVES WITH ACCESS PANEL. l�Jl1�l ACKSON I MAIf R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM A(NFMAN F IN E E 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY OF E DEVELOPMENTT SERVICES DEPARTMENT 0 z O o CN 0 LLI >Q LU J Q LL OQ� 0 U) Q � � Q O O LLIQ2 J M UMLLI VJ 0 z(D Z U)O C0 G 0 W � � LU J � � Q LL mO�� O ��VJ �z��0 Lu -)Q 0 z 0 00 0- Q 0 2 0- W J z O H � �m a D U U) o� LU z� LU Q oC:) 10/5/21 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON LEVEL 1 PLUMBING PLAN P1 2 ■ JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: 1. ROUTE HOT WATER MAIN WITHIN 2FT OF PUBLIC LAVS PER WSEC MAXIMUM ALLOWABLE PIPE LENGTH METHOD. 1 2 3 4 5 I I I I I I I I I I I I I I I I I I I I I I I I I I I I E I I I I JD I I I I I I OFFICE 6 OFFICE 5 OFFIICE 4 OFFICE 3 OFFICE 2 OFFICE 1 ----------------------- 206 i 205 214 203 i 202 201 I I I I 3"V UP 1-1/2"CW DN I TO 3"VTR I FFE=29'-0" 1 "HW DN 1-1/2 "CW -kRCHI� ------------------------------- ----- ROOM I 209 AUDIT 3"V DN & COMMISSION MEETING 211 U�0 3"VTR I ROOM SERVER I ' 218 ° 2"V 212 1/2"C I I ' Li - - - - - --T/TH - -- - - - - - - - - - - - - - - - - - -- - - - - - C & 2"V -�-- LOBBY 3/4"CW LR7 V_2 200 LA 0 & 2 'V TO I L I 1-1 /2 CW� 3/4 HWC DN I — 1 I I 1_ 1 /2„CW, 3/4„HWC I I I 2„V, 3/4"HWC WC-1 (2)2"V DN UP I 1-1 /2"CW&HW D N TO LAV-1 WC- 3 CAPPED - - - - - - -\' ,- - - - - - - - - --- --- HW - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �_ _� F UBE_ B DN TO AS-1 MEN'S',� I 214 'II 2"VDN MS "III 3"V R P TO KEYNOTES: , 1 2 C I -- ° DF-1 ix\ 1/2"CW i I J[Ojov� 0 1 PROVIDE BALANCING VALVE, CHECK VALVE, AND ' 1 /2 CW, 1 /2 HW, I D ISOLATION VALVES WITH ACCESS PANEL. 2„U, 3/4»HWC � � --- � „ WB-71 1-1/2 CW CAPPED 1 /2"HW DN I -T 1-1 /2"CW FOR FUTURE TO SK-1 & DISHWASHER - - - 1-1 /2"CW I 1 9REAK ROOM LEASEABLE I o ; LK -1 216 OFFICE ' STORAGE 217 JE Y d ° i I I - - 3/4»CW ° 3/4"CW DN TO ° HB. LOCATE ' SHUTOFF VALVE 4' ABOVE FLOOR LEVEL 2 PLUMBING PLAN SCALE: 3/16" = 1'-0" Q Cn 00 0 0 N 0 N N N Nil ivl ACKSON I MAIf R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM FMAN AF(N 6 1 N E E 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY OF E DEVELOPMENTT SERVICES DEPARTMENT 0 z O (lj > 0 w Q 3 0�0 rn LU J Q LL p < Q Z - � � O LLIQ2i J M UMLLI 0 z CD z .. (� o CVO �0w�� OJ LLl � � Q LL m�J� O U) �z��0 � Q 0 0 0- C)2 Q °�0 0- � Lu J Z o� H a m U U) H LU o� LU a z� LU Q� o� K, PROJECT NO.: PROJECT MGR. DRAWN BY: CHECKED BY: LEVEL 2 PLUMBING PLAN 210887 ON CEI ON P1 3 ■ JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: 1. ROOF DRAINAGE VIA EXTERIOR GUTTERS AND DOWNSPOUTS BY ARCHITECT. REFER TO ARCHITECTURAL PLANS FOR GUTTERS AND DOWNSPOUTS AND REFER TO CIVIL PLANS FOR CONNECTION TO STORM DRAIN. i PLUMBING ROOF PLAN SCALE: 3/16" = 1'-0" - - - - - ---C) - - - - - ---(A) KEYNOTES: NJ I ivl ACKSON I MAIf R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM AF!RFFMAN ll€EEIi 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY OF E DEVELOPMENTT SERVICES DEPARTMENT 0 z O _C) CN 0 w W rn w 0/ J Q ' 0 O 00�U) 0 0 O wQ2i JM0 U cY) w 0 z CD O Z U) o �Ow>-00 OJ w 0 �Q L.LmO�� O . ��c) 0 �z( �Q0 00��0 0—Qw w J Z O~ a m D U Cn ~ CO W 0 � W d Z LU N Q � O 0 - 10/5/21 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON PLUMBING ROOF PLAN P 1.4 JACKSON I MAIN ARCHITECTURE P.S. © 2021 ROOF LEVEL 2 LEVEL 1 4"W (118 DFU) SEE CIVIL FOR CONTINUATION ROOF ------r-----T-----------rl-----r-------T----- T----� I I MEN I I I WOMEN I I I R.R. I > ;?1 �I R.R. -> I > I CUSTODIAL �> I > I BREAKROOM N I 1 N NI NI N1 c l l N1 C,41 1 N I #213 1 I I #214 1 I #215 1 1 521fl 1 1 LAV-1 I I I I LAV-1 1 DF-1 1 DF-1 1 SK-1 I I I I 1 4"W 1 �� I � o 1 (4DFU)I No 3W1 �� N N N FD-1 I WC-2 1 2 TYP I WC-2 (3 DFU) I MS-1 N �. CO-1iii 4"W 4 W 4 W 3"W 2"W 2"W CO-1 „ 2 DFU 15 DFU (11 DFU) (7 DFU) (6 DFU) (3 DFU) (2 DFU) 4"W FOR FUTURE L (2 DFU) r-----T-----r----�- I I I I 3"V 1 FIRE 1 I MECH I FOR FUTURE ? 1 RISER ? 1 Ni ? 1 RM e I Ni NI RETAIL Ni I #111 I #110 I I FD-1 I FFD-1 I FD-1 I FFD-1 I FCO-1 T72 „ I I I DFU 79 DFU 2 DFU 2 DFU T „ 4 W 8 DFU .—. D1 A"W (7a 4"W 8 DFU nFll) ( ) 19 DFU) FCO-1 4"W 39 DFU 63 DFU ALLOWANCE FOR BACKWATER BLDG EXTERIOR FUTURE RETAIL SPACE VALVE WALL I I _ ICn I Lci I I � I 00 I � I cp I �I U N I LEVEL 2 I 3/4"HWC (2 GPM) I I I� � I I � I I I � CIO � I I = I I HB-1 - 3/4"CW (2.5 WSFU) - CIRC PUMP 1 1 "CW _ CP-1 ' (7.9 WSFU I TO WATER HEATER. REFER TO DETAIL 11 /P4.1 LEVEL 1 Q Cn 00 0 0 N N N I I I I MECH RM ' I #110 � o � O N FCO-1 FCO-1 4"W (8 DFU) 4 4"W (19 DFU) WASTE & VENT RISER DIAGRAM SCALE: NONE �I �I I I P 3"V FOR FUTRE I I I �I I I I I I I I I L-T-- - - - - T - - - 1 URINAL R.R. 1 �I �I OFFICE SPACE N I N I #104B N 1 N 1 (19 DFU ALLOWANCE) I I I ^ LL_ 0 rn FCO-1 FCO-1 4"W — i 1/ (8 DFU LAV-1 I I L UR-1 �Ij �0 4„W I �o = N 1 N FCO-1 C,4 o =- (4 DFU)I WC-1 4„W 4„W (5 DFU) (1 DFU) LEGEND DFU WC-1 WATER CLOSET 4 LAV-1 LAVATORY 1 UR-1 URINAL 2 SK-1 KITCHEN SINK 2 MS-1 MOP SINK 3 FD-1 FLOOR DRAIN 2 DF-1 DRINKING FOUNTAIN 0.5 ROOF ROOF LEVEL 2 UNISEX R.R. # 104A FCO-1 LEVEL 1 SHEET NOTES: GPM) -- -- 1-1/2"CW - -- -- -- -- -- - -- -- (23 WSFU __� _ _ _ _ _ _ _ _ _ _ _ _ _ _3�'HW�6 _WSFU_ _ _ _ �4"HW�4.9 WSFU _ _ _ _2"HW �2.6 WSFU __ _ _ ALLOWANCE) 2„CW - - 2,�CW - - N - 2„CW - - - 2,�CW - 1-1 znCW - - - - - - - CAPPED ^� (44.1 WSFU) (40.1 WSFU) (30.1 WSFU) ^� (29.4 WSFU) 1 �(27.1 WSFU) � 1 �� FOR 1 11 ^I 1 1 , FUTURE I I Ll- LI_ I _ _ I Ll— LI_ I v) l � WOMEN v) l � Li- � '� ' � ' 3: � ' � �� MEN v� v� �� �� �� 3I� �1 3 �1 1 U) R.R. � LL_ R.R. I CUSTODIAL � I 1 � BREAKROOM U-) I U-) I � UI 2 UI UI 2 I UI U1 UI C) 2 N 2 CL I N1� I Cv �12 �12 Iin N1� I N UILo I = ICE NI� � � NIQ NIA' N � I N Ln I CD #213 #214 0 #215 N- #216 I �l�ol\lro �� N\Ir ��. �� � ��. I ��. �� N \N ��i h7.� ��i ��i �� �� KEYNOTES: LAV-2 UR-1 WC-1 WC-1 LAV-2 MS-1 DF-1 WB-1 SK-1 DISHWASHER I 1 /2"HW (2.1 WSFU) TO HB-1 �I LEVEL 2 --- -- -- -- -- 1/2"HWC (1.0 GPM) -- -- 2 "CW _ (74.5 WSFU) I u 1-1 /2"CW (63 WSFU) CAPPED FOR FUTURE I RPBP-1 I 2-1 /2"CW (126 WSFU) (74 GPM) _ 1.5_WSFU,_ _ _ _ _ _112"HW_ 0.75 WSFU _ --- -- -- -- -- -- -- -- -- -- _ 2"CW - 1-1/2"CW - 1-1/2"CW - 1-1 2"CW 1-11 2"CW 1-1 2"CW 13.5 WSFU �12.5 WSFU 11.5 WSFU (7.5 WSFU) (6!75 WSFU) (1.75 WSFU) =D =D =D =D TO HB-1 3 4"CW TO HB-1 3 4"CW � � 3 I� � � � � 1 � 3/4 "CW TO HB-1 (1 WSFU) (1 WSFU) v � U L, I= LO v i c� �, 1j: Ln (1 WSFU) NII\ N r— �I3: NIA N r-- Q I\ O Q\ 1O In �i I LEGEND WSFU COUNTS LABEL CW HW WC-1 5 - LAV-1 0.75 0.75 HB-1 1 - UR-1 4 - DF-1 1 - MS-1 2.25 2.25 SK-1 1.125 1.125 DOMESTIC WATER RISER DIAGRAM SCALE: NONE URINAL IUNISEX UR-1 R.R. LAV-1 WC-1 R.R. LAV-1 #1046 #104A LEVEL 1 JACKSON I MAIN ARCH ITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324A800 WWW.JACKSONMAIN.COM lIfi �QFFMAN ll€EEIS 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 z 0 0 U CN � 0 warn Q LIJ J Q Q O Q U' 0 Q O LL I J M 0 U cY) W U) 0 z CD 0 Z U) o W >- rn 0 LIJ J 0 Q 3: Q LLmO_� 0 . z ��c) U2i0 —)Q0 Q 0- � W J Z 0 H ~ a m Cn U Cn o� LU a o� Z W I- c7I LO o p — 10/5/21 PROJECT NO.: 210887 PROJECT Mi ON DRAWN BY: CEI CHECKED BY: ON RISER DIAGRAMS P201 JACKSON I MAIN ARCHITECTURE P.S. © 2021 18 GAUGE ROUND GALVANIZED STFr' CLEANOUT TEE ACCESS COVER FINISHED WALL CLEANOUT PIPE WALL CLEANOUT DETAIL SCALE: NONE FLOW 30LATION VALVE (TYP) QAI Anlrr VALVE (TYP) CHECK VALVE HWC BALANCE VALVE DETAIL SCALE: NONE FLOOR UNION (TYPICA11 SHUT-OFF V Y-STRAINER FLOW LONG SWEEP BEND SEE PLANS FOR SIZES FLOOR CLEANOUT DETAIL SCALE: NONE CAULK AIR KEYED ACCESS HATCH 3/4" HOSE CONNECTION W/ INTEGRAL VACUUM BREAKE FACE PLAT SEAL AIR TIGHT W/ WEATHERPROOF INSULATING CAULKING 3/4" CW HYDRANT VALVE 14" MIN. FROM EXTERIOR WALL WALL CLAMP EXTERIOR WALL SEE ARCHITECTURAL TYP. EXTERIOR HOSE BIBB SCALE: NONE REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL WITH FLOOR PENETRATION DRAIN LINE TO SLEEVE FLOOR DRAIN "Ol 2-1 /2" WATER SERVICE PRESSURE GAUGE W/ GAUGE COCK (TYPICAL) VACUUM BREAKER HOSE BIBB CONVENIENCE OUTLET DOMESTIC WATER ENTRY DETAIL SCALE: NONE BOLT STIR, DRA INDIRECT DRAIN PIPE �2" MINIMUM TYPICAL FUNNEL DRAIN DETAIL SCALE: NONE ELASTOMERIC INSULATION CUSION STEEL OR SCHED 40 PVC SLEEVE, 1 1/2" x DIA. OF PIPE SILICONE CAULK SEAL CONCRETE FLOOR OR WALL FLOOR nonlni eTonlni�o FINISHE 2" 6" LEAD AI NEOPRI FLOOR DRAIN SCALE: NONE HW/CW SUPPLY INSTALL PER PDI STANDARDS AND MANUFACTURER'S RECOMMENDATIONS PDI SIZE "A" UV 1 V V I V V U SINGLE FIXTURE MULTIPLE FIXTURES NOTES: D IF HORIZONTAL BRANCH IS LESS THEN 20' LONG, INSTALL ONE WHA AT THE END OF THE LINE BETWEEN THE LAST TWO FIXTURES. IF THE HORIZONTAL BRANCH IS GREATER THAN 20' LONG, INSTALL ANOTHER WHA IN THE MIDDLE, DIVIDING THE FIXTURE UNITS BETWEEN EACH AND SIZING ACCORDINGLY. 2. PLUMBING CONTRACTOR TO PROVIDE BELOW TYPE WATER HAMMER ARRESTORS BY ZURN. ALTERNATES: MIFAB, PRECISION PLUMBING PRODUCTS, WATTS SOUX CHIEF OR APPROVED EQUIVALENT WITH NESTED TYPE BELLOWS, HAVING PDI #WH-201, ASSE #1010 AND ANSI #A112.261 M CERTIFICATION. 3. INSTALL IN THE VERTICAL OR HORIZONTAL POSITION, NEVER UPSIDE DOWN. 4. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. 5. SIZE THE UNITS AS SHOWN ON THE TABLES. 6. INSTALL ALTERNATES IN AN ACCESSIBLE LOCATION OR WITH ACCESS PANEL. PIPE PENETRATION THRU CONCRETE SCALE: NONE NON-SUDSING SUDSING STACK STACK STACK WASTE DRAIN SUDSING NON-SUDSING STACK STACK SUDS RELIEF DETAIL SCALE: NONE STACK ANY DISTANCE WASTE DRAIN CERAMIC TILE AND SETTING BED WATERPROOF MEMBRANE CONCRETE FLOOR SLAB FIXTURE UNIT TABULATION FIXTURE COLD HOT WATER CLOSET - FLUSH TANK 10 -- URINAL 5 -- LAVATORY 1 1 SINK 2 2 JANITOR'S SINK 2.25 2.25 WASHING MACHINE/ICE MAKER 1 1 DISHWASHING MACHINE 2.25 2.25 ARRESTOR SIZE TABLE PDI SIZE PIPE SIZE FIXTURE UNIT LOAD A 1/2 1-11 B 3/4 12-32 C 1 33-60 D 1-1/4 61-113 E 1-1/2 114-154 F 1 2 154-330 WATER HAMMER ARRESTOR DETAIL SCALE: NONE BALL VALVE (TYP) CHECK VALVE (TYP) NO LOAD BALANCE GLOBE VALVE THERMOMETER (TYP) REDUCER (TYP, IF REQ'D) A.S.M.E. TEMP -PRESSURE RELIEF VALVE FULL SIZE DRAIN TO MOP SINK SEISMIC RESTRAINT (TYP) ROUTE DRAINS TO FUNNEL FLOOR DRAIN GALVANIZEDDRAIN PAN SHEETMETAL T EXPANSION TANK ET-1 I WH-1 SET TO 120°F FLOOR ow TIMER AQUASTAT CP-1 T P/T UNION (TYP) Y-STRAINER W/ BLOWOFF & HOSE THREAD CONNECTION INLINE CIRCULATING PUMP, SEE DETAIL 4/P401 FLANGES (TYP) MANUAL BALANCING VALVE 4" CONCRETE PAD HOT WATER HEATER DETAIL SCALE: NONE NJ I ivl ACKSON I MAIf R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM AFRFFMAN I11 E E 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships RECEIVED Oct 14 2021 CITY OF E DEVELOPMENTT SERVICES DEPARTMENT 0 z O 2 � 0 W Q � O� W J Q Q O U' Q 0 ~ zC)0 Q O W J M 2 0 U co W v) 0 z CD O z U) CD�Dw>-00 OJ W 0 �Q L.LmO�� O z c) L.L -)Q0 O 0 Q 0� ,� 0 W W J Z O~ I- 02 -m E D U) U U w o � w a O z Q in o p If 93341 ANAL PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON DETAILS P401 JACKSON I MAIN ARCHITECTURE P.S. © 2021 -7 META T WITH HOSE END AILHOOK CE FAUCET WITH VACUUM BREAKER FOOTING OR BOTTOM GRADE BEAM (SEE STRUCTURAL PLANS FOR DETAILS) STAINLESS STEEL 3/4" TIE RODS (TYP) WHEN THIS PIECE EXCEEDS HALF A LENGTH, STRAPS MAY BE RUN ONLY TO FIRST OUTSIDE JOINT NOTE: WALL TYPE K COPPER WATER MAIN DUCTILE IRON FLANGE AND SPIGOT PIECE LINK -SEAL THRU CONCRETE SLAB �.. I€ � �illl®IIII®IIII®IIII® THRUST BLOCK DUCTILE IRON PIPE SLEEVE PIPE AND SEAL ANNULAR SPACE BETWEEN DRAIN AND SLEEVE l�Jl1�l ACKSON I MAID RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM �FFMAN H&II€EEIS 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships 1. COAT ALL TIE RODS WITH 2 COATS OF COAL TAR ENAMEL TO PREVENT CORROSION. RECEIVED Oct 14 2021 /� CITY OF EDMONDS WATER SERVICE MAIN n / DEVELOPMENT SERVICES DEPARTMENT 1 MOP SINK DETAIL 2 ENTERING BUILDING DETAIL 3 DISHWASHER WASTE DETAIL z 0 �.2SCALE: NONE �.2SCALE: NONE �.2SCALE: NONE Q 00 0 Uj Uj 0� J Q LL DQ� HANGER ROD = HANGER ROD Q C Q W/ JAM NUT = W/ JAM NUT 0 z � IzQOC Cy) 0 BALL VALVE (TYP) 0 G CLEVIS HANGER = CLEVIS HANGER J PCW MAIN �� 0- U (y) w PIPE INSULATION - UPPER HALF OF PIPE OVERLAPPING GALVANIZED SHEET METAL PROTECTION SHIELD PROTECTION SADDLE DOUBLE THICKNESS JACKET BOTTOM INSULATION INSERTED IN SADDLE CAVITY DETAIL'A' HOT PIPE: 4" DIAMETER AND LARGER (60' F & HIGHER) E INSULATION - 'ER HALF OF PIPE RLAPPING -VANIZED SHEET LAL PROTECTION ELD H DENSITY INSULATION INSERT - LOWER HALF OF PIPE DETAIL 'B' HOT PIPE UNDER 4" DIAMETER COLD PIPE ALL SIZES 4 PIPE HANGERS WITH INSULATED PIPE DETAIL M4.2 SCALE: NONE Q Cn 00 0 0 N 0 N N N Q0 PPP PRIME TIME ELECTRONIC TRAP PRIMING ASSEMBLY, 120V SURFACE MOUNT :,_, VACUUM BREAKER 1/2" PEX TUBING TO P-TRAPS (TYP) 0 cfl 00 it 3/4" TO FLOOR DRAIN/SINK P-TRAP 24 HOUR TIMER MANUAL OVERRIDE SWITCH/TEST BUTTON 2A FUSE SOLENOID VALVE WATER SOURCE CONNECTION CALIBRATED MANIFOLD WITH 1/2" TUBE CONNECTIONS, SEE PLANS FOR QUANTITY. SLEEVE & SEAL WATERTIGHT PENETRATIONS THROUGH FLOOR (TYP) FLOOR PRIME TIME ELECTRONIC TRAP ('_5 PRIMING ASSEMBLY DETAIL �M4.2SCALE: NONE WALL CO SEE ARCI SEALANT PIPE AND INSULATI( WALL TYf )VIDE ESCUTCHEON ,LL FINISHED AREAS ) AREAS THAT ARE IBLE. _V. STEEL SLEEVE 2" =ATER IN DIA. THAN JETRATING PIPE. s SLEEVE FOR PIPING THRU INTERIOR WALL �MUSCALE: NONE CJ J 0 z CD 0 z v, N �Dw>_ 00 0 LIJ�D3:Q < LLmO_� O z ��c) U�0 L.L G —)QD 0 0 Q 0- � W J Z O H � �m 0U) U W � o� LU a O z W N L0 Q O 0 W , J 99941 N�SI^I g -gip ANAL PROJECT NO.: 210887 PROJECT Mi ON DRAWN BY: CEI CHECKED BY: ON DETAILS P402 JACKSON I MAIN ARCHITECTURE P.S. © 2021