REVIEWED FIR2023-0066+Fire_Sprinkler_Equipment_Specification_Sheets+7.7.2023_7.22.22_AM+3652173
Duffy Residence 23511 74th Ave W. Edmonds, WA 98026 Fire Sprinkler Product Submittal Data Emerald Fire Fire Sprinkler Specialists 11021 Cramer Rd NW — Gig Harbor, WA 98329 EMERAFL980MR — EmeraldFireLLC.com Fire Sprinkler Product Submittal Data 1. Tyco TY2534 LFII %" 4.9 K — Factor 155* White Pendent Sprinkler 2. Viking Vk182 1" 5.6 K— Factor 155* Dry Barrel Sprinkler 3. Blazemaster 1" CPVC Pipe & Fittings 4. Potter 6" Electric Bell PBA-AC 12-VAC 5. Argo Spare head Cabinet 6. Anvil Fig 188R Offset pipe hanger 7. Anvil Fig 187 Side mount pipe hanger 8. Potter RD13 Residential Riser 9. Ames 2000B double check backflow asssembly tqcao Worldwide I Contacts I www tyco-fire.com RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe System IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/ rapid-response-4_9k General Description The TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY2534) are dec- orative, glass bulb sprinklers, avail- able in both ordinary 155°F (68°C) and intermediate 200°F (93°C) tempera- ture rated configurations. They are designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers provides 3/4" (19,1 mm) vertical adjustment. This adjust- ment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: • Wet pipe residential sprinkler sys- tems for one and two family dwell- ings and mobile homes per NFPA 13D • Wet pipe residential sprinkler sys- tems for residential occupancies up to and including four stories in height per NFPA 13R • Wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY2534) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. NOTICE The Series LFII Residential Concealed Pendent Sprinklers (TY2534) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY2534 Page 1 of 6 NOVEMBER 2021 TFP446 TFP446 Page 2of6 Technical Data Approvals UL and C-UL Listed The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII Con- cealed Cover Plates having factory -applied finishes. Sprinklers and Cover Plates are separately ordered. See the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi", (70,6 LPM/bar'') Temperature Rating Ordinary 155°F (68°C) Sprinkler 139°F (59°C) Cover Plate Note: Maximum Ambient Ceiling Tempera- ture for the ordinary temperature configura- tion is 100°F (38°C). Intermediate 200°F (93°C) Sprinkler 165°F (74°C) Cover Plate Note: Maximum Ambient Ceiling Tempera- ture for the intermediate temperature con- figuration is 150°F (65°C). Vertical Adjustment 3/4 in. (19,1 mm) Finishes See the Ordering Procedure section Physical Characteristics Frame .............................Brass Support Cup ...................Plated Steel Guide Pins ................. Stainless Steel Deflector..........................Bronze Compression Screw .................. Brass Bulb...............................Glass Button ................... Phosphor Bronze Sealing Assembly. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer ......................Plated Steel Cover Plate Ejection Spring .... Stainless Steel Bridge............................Bronze Bridge Ejection Spring ............ INCONEL Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector, supported by the Guide Pins, then drops down to its operated position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. SUPPORT FRAME CUP WITH (1/2" NPT) ROLLFORMED THREADS SPRINKLER WRENCH SEALING FLATS ASSEMBLY BUTTON GUIDE PIN BULB BRIDGE BRIDGE EJECTION SPRING COMPRESSION SCREW DEFLECTOR (OPERATED DEFLECTOR II II POSITION) SPRINKLER ASSEMBLY THREAD INTO RETAINER SUPPORT WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS o 0 FLUSH WITH CEILING EJECTION SPRING SOLDER COVER PLATE COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY2534) TFP446 Page 3of6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2,3 Maximum Coverage Maximum Temp. Rating Area' Sp ft 155°F (68°C), 200°F (93°C) Minimum ft x ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type ft GPM Psi (m) (LPM) (bar) 12 x 12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 13 7.0 3/8 to 1 1/8 in. (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0 (4,9 x 4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in (2,4) 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 3/8 to 1 1/8 in. below bottom 20 x 20 20 20 16.7 of beam (6,1 x 6,1) (6,1) (75,7) (1,15) Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 GPM/fV over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY2534) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY2534) are LIL and C-LIL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area • A minimum discharge of 0.1 GPM/ft2 over the design area comprised of the four most hydraulically demand- ing sprinklers for actual coverage areas protected by the four sprinklers Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (see Table A) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. TFP446 Page 4 of 6 Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY2534) must be installed in accordance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb, With the sprin- kler held horizontally, a small air bubble should be present. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under -or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads and using the W-Type 42 Wrench shown in Figure 3, position the wrench recess to first straddle the deflector guide pins from the side and then push the wrench into the support cup to engage the sprin- kler wrench flats. Rotate clockwise to tighten the Sprinkler/Support Cup Assembly into the fitting. The W-Type 42 Wrench will accept a 1/2 in. ratchet drive. Note: Do not engage the sprinkler frame arms by the wrench, engage only the sprinkler wrench flats. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceil- ing installation and/or during applica- tion of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2 1/2 in. (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in con- tact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. WRENCH RECESS O� 0 1/2" SQUARE DRIVE SOCKET FIGURE 3 W-TYPE 42 SPRINKLER WRENCH TFP446 Page 5of6 Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY2534) must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is an air gap between the lip of the Cover Plate and the ceiling. The Cover Plate assembly has a nominal 3/32 (2,4 mm) air gap, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situ- ation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non -factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY2534) 4.91K Res- idential Concealed Pendent Sprinkler, P/N (specify): 155°F (68°C).................. 51-549-1-155 200oF(93oC) .................51-549-1-200 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFII Concealed Sprinkler Cover Plate Assembly, temperature rating (specify), (specify) finish, P/N (specify): 139°F(59°C) Ivory (RAL1015) ...............56-891-0-135 Bright Chrome ...............56-891-9-135B Beige (RAL1001) ..............56-891-2-135 Pure White (RAL9010)* .........56-891-3-135 Signal White (RAL9003)** .......56-891-4-135 Grey White (RAL9002).......... 56-891-5-135 Brown(RAL8028)..............56-891-6-135 Black (RAL9005) .............. 56-891-7-135 Brushed Brass ................56-891-8-135 Brushed Chrome ..............56-891-9-135 Custom Paint .................56-891-X-135 165°F (MoC) Ivory (RAL1015) ...............56-891-0-165 Bright Chrome ...............56-891-9-165B Beige (RAL1001) .............. 56-891-2-165 Pure White (RAL9010)* .........56-891-3-165 Signal White (RAL9003)** .......56-891-4-165 Grey White (RAL9002).......... 56-891-5-165 Brown(RAL8028)..............58-891-6-165 Black (RAL9005) .............. 56-891-7-165 Brushed Brass ................56-891-8-165 Brushed Chrome ..............56-891-9-165 Custom Paint .................56-891-X-165 Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using SHERWIN-WILLIAMS Interior Latex Paint. Contact Johnson Controls Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 42 Sprinkler Wrench, P/N 56-000-1-079 Page 1 of 8 ® QUICK RESPONSE - DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry HSW Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 illlllil�lll lil For Light Hazard Occupancies Only on a more frequent basis. WARNING: Cancer and Reproductive Harm- 2. LISTINGS AND APPROVALS www.P65Warnings.ca.gov OL cULus Listed: Category VNIV c us FM Approved: Classes 2013 and 2015 <FM> NYC Approved: MEA 89-92-E, Volume 15 Refer to Approval Chart 1 and Design Criteria on page 106c for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 106d for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Available since 1993. The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar) http://www.vikinggroupinc.com. Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) The Web site may include a more recent Thread size: 1" NPT or 25 mm BSP edition of this Technical Data Page. Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass -bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patent numbers: 8,636,075 and 8,376,060 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the wall in which it is to be installed. Form No. F_031993 19.06.24 Rev 19.1 Replaces Form No. F_031993 Rev 15.1.P65 (Added patent number.) Page 2 of 8 ® QUICK RESPONSE - DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made -to -order" basis: Recessed Dry HSW up to 65- 1/2" (1,664 mm). Adjustable Standard Dry HSW up to 63-1/2" (1,613 ni Plain Barrel Dry HSW up to 65" (1,651 ni Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). For example, sprinkler VK182 with 1" NPT Threads, a Chrome finish, a 155 °F (68 °C) temperature rating, the Model G-1 Escutcheon, and "A" length of 10" = Part No. 08386UFBY10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A''W' ratchet is required (not available from Viking). Dry Sprinkler Protective Cover: Part No. 15610 Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 08086F B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the water - NOTE Sprinkler is turned sideways for clarity(Refer to Figures 2-7 for correct deflector orientation) Protective Sprinkler Shleld Wrench Flat VIKING o 17 0 1I way. Water flowing through the sprinkler orifice strikes the sprinkler deflector, Figure 1: forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Standard Sprinkler Wrench 07297W/B Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Horizontal Sidewall Sprinkler is available through a network of domestic and international distribu- tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' CeilingTemperature 2 Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F 93 °C 150 °F 65 °C Green High 286 °F 141 °C 225 °F 107 °C Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion -Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- cated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT corrosion proof. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. ^ When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Form No. F_031993 19.06.24 Rev 19.1 Page 3 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Wrench Part No. 07565W/B)KK- for installing recessed dry sprinklers. --------------- i --- , *)KNote: A 1/2' ratchet Is required (Not available from Viking). -------------- i 1 Step 1: Carefully slide the W Step 2; Press the wrench onto wrench sideways around the the sprinkler wrench flats and deflector and protective turn slightly to ensure engage - shield as shown. vent with the wrench flats. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Horizontal Sidewall Sprinklers For 'A' Dimension: 1 Determine the distance from the face of the tee to the finished face of the wall. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' (38.1 mm) and 45-1/2' (1,156 mm). NOTE: The deflector will extend approximately 4-1/8' (104.8 mm) from the wall with 2' +/- 1' (25.4 mm) horizontal adjustment available. A - Minimum wall opening diameter, 1-3/4' (44.5 mm). Maximum wall opening diameter, 2-1/4' (57 mm). Slot rTMcntor �___ JP Sleeve Finished Ceiling eflector at D Minimum Distance From Wall NOTE: To locate the deflector at the minimum distance from the wall, with no Finished Wall adjustment available, order the standard dry 4' (102 mm) Minimum 6' (152 mm) Maximum)K 3-1/8 horizontal sidewall sprink- ler 1' (25.4 mm) shorter than the 'A' Dimension. (79.4 mm) - - - 3-1/16' Deflector at Maximum Distance NOTE: To locate the deflector (77.8 mm) From Wall at the maximum distance from the wall, with no a adjustment vailable, order the standard dry (15.9 mm) horizontal sldewall sprink- ler 1' (25.4 mm) longer than the 'A' Dimension. --,--.I Sleeve diameter) (130,2 mm) 1-1/2' (38.1 mm). -13/16' Sleeve finish matches x May be allowed up to 18' (457 mm) for certain (20.6 mm) finish of escutcheon. FM installations, Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler )t STEP 1; Align the slot In STEP 2; Push the rounded STEP 3; Pull the escutcheon STEP 4, Push and rotate STEP 5; To minimize the escutcheon with the end of the slot against the away from the near edge the escutcheon onto the visibility of the slot horizontal surface of near edge of the deflector, of the deflector. Move the sleeve. in the escutcheon, the deflector as shown, Push the far side of the near side of the escut- position the slot escutcheon past the deflec- cheon over the deflector. at the top of the tor, toward the sleeve, sprinkler sleeve. Form No. F_031993 19.06.24 Rev 19.1 Page 4 of 8 ® QUICK RESPONSE - DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers Finish For Light Hazard Occupancies Only A1X4- Escutcheon (if applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal Order Length Listings and Approvals' Part No.' SIN Style K-Factor 2 Increment (Refer also to Design Criteria on page 106e.) NPT BSP U.S. metric' Inches mm cULuss NYC6 VdS LPCB (E Q 08384U VK178 Adjustable Standard 1" 5.6 80.6 1/2" 12.7 A1, A5 Al -- -- -- -- 16458U -- 25 mm -- 80.6 1/2" 12.7 A1, A5 -- - -- -- -- 08386U VK182 Adjustable Recessed 1" 5.6 80.6 1/4" 6.35 B2, B6 B2 - -- -- -- 16454U -- 25 mm -- 80.6 1/4" 6.35 B2, B6 - - -- -- -- 08388U VK174 Plain Barrel 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- -- -- 16456U -- 25 mm -- 80.6 1/2" 12.7 A3 - -- -- -- -- Approved Finishes and "A" Dimensions 1* - Chrome, or White Polyester' sprinkler with a Chrome, Brass, or White Polyester Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) Approved Temperature Ratings 2* - Chrome, or White Polyester' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 A - 155 OF (an 1OF OF , 200 OF "A" 28 1 'C) (93 °C), and 286 °F (141 °C) 3 - Chrome, Brass, White Polyester', or ENT' with dimensions 3" to 47" (76.2 mm to 1,194 mm) "A" B - 155 OF (68 °C), 175 OF (79 °C), and 4 - Chrome or Brass with dimensions 3" to 47" (76.2 mm to 1,194 mm) "A" 200 OF (93 °C) 5 - ENT' sprinkler with an ENT' Sleeve and Escutcheon with dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6 - ENT' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) "Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. s Listed by Underwriter's Laboratories for use in the U.S. and Canada for Light Hazard occupancies only. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. ' cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- tion of NFPA 13 for standard spray sprinklers. • Limited to Light Hazard occupancies only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Deflector must be positioned between 4" and 6" (102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4" (102 mm) from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031993 19.06.24 Rev 19.1 Page 5 of 8 ® QUICK RESPONSE - DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers Finish For Light Hazard Occupancies Only A1X-4 Escutcheon(if applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal K-Factor2 Order Length Increment FM Approvals' Part No. SIN Style (Refer also to Design Criteria below.) NPT BSP U.S. metric' Inches mm 08384U VK178 Adjustable Standard 1" -- 5.6 80.6 1/2" 12.7 Al 16458U -- 25 mm -- 80.6 1/2" 12.7 Al 08386U VK182 Adjustable Recessed i" -- 5.6 80.6 1/4" 6.35 B2 16454U -- 25 mm -- 80.6 1/4" 6.35 62 08388U VK174 Plain Barrel i" -- 5.6 80.6 1/2" 12.7 A3 16456U -- 25 mm -- 80.6 1 1/2" 12.7 A3 Approved Finishes and "A" Dimensions 1* - Bright Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 1-1/2" to 45-1/2" (38.1 Approved Temperature Ratings mm to 1,156 mm) 2* - Bright Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 3-1/4" to 47-1/2" (82.5 A- 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and mm to 1,207 mm) 286 °F (141 °C) 3 - Brass, Bright Brass, Chrome, White Polyester, or ENT5 "A" dimensions 3" to 47" (76.2 mm to B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 1,194 mm) *Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reauirements: The Dry HSW Sprinklers in the Approval Chart above are FM Approved as quick response Non -storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflec- tor distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other simi- lar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031993 19.06.24 Rev 19.1 Page 6 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For 'A' Dimension 1. Determine the distance from the face of the tee to the face of the finishewall. 2. Round to the nearest 1/4' (6.35 Clmm) between 3-1/4' (83 mm) and 47-1/2' (1,207 mm). NOTE: The sprinkler will be recessed approximately 5/16' (7.9 mm) with 5/8' (16 mm) horizontal adjustment available. A II Minimum wall opening: 2-1/8' (54 mm) diameter. Maximum wall opening: L iu 2-1/2' (63.5 mm) diameter. May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0, \-Ceiling Wall 4' (102 mm) Minimum 6' (152 mm) Maximum)K 5/8' (16 mm) 3-1/16' _ (77.8 mm) II II Available Adjustment 1-23/32' (43.7 mm) Minimum 2-11/32' (59.5 mm) Maximum 5/16' (7.9 mm) Outward Adjustment 5/16' (73 mm) Inward Adjustment Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model E-1 Escutcheon Side outlet of --` Tee turned to req'd angle for slope of ceiling Adjustable Adapter Ring Depth, 1-1/16, (27 mm) 1/8, (3,2 mm) Ad,Justable Outer Cup T 2-5/8' 4' (66 mm) (102 mm) 1-1/16l' (27 Figure 6 For 'A' Dimension 1. Measure B Dimension from centerline of the Face of the tee to the horizontal centerline of the wall opening. 2. Measure C Dimension from the centerline of the Face of the tee to the finished wall q 3. Calculate 'A' Dimension usingi A = VT C NOTE, A Dimension will provide approximately 1/4' of aciiustment In either direction. Ceiling �iL Deflector distance f Def lJ 4-6' cto to 1ta me below the ceiling,)K Minimum wall opening: When measuring for 2-5/8' (66 mm) diameter, Maximum wall openings 3-3/4' (95 mm) diameter. . ,�; �. ; the 'A' Dimension, Wall the exact deflector �� distance below the ceiling must be known. C )K May be allowed up to 18' (457 mm) for certain FM Installatlons. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model G-1 Escutcheon Form No. F_031993 19.06.24 Rev 19.1 Page 7 of 8 ® QUICK RESPONSE - DRY HORIZONTAL 4 I KiSIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For 'A' Dimension: 1. Determine the distance from the face of the tee to the base of the sprinkler, Ceiling 2. Round to next highest 1/2' (12.7 mm) increment, between 3' (76 2 mm) and Wall 47' (1,194 mm). 4' (102 mm) Minimum 6' (152 mm) Maxlmum)K A 2-3/16' (51 mm)7 5/8' (16 mm) air 47—� Outside diameter 1-5/16" J (33.4 mm), (Same as 1' Do not exceed 6' (152 mm), (25 mm) Schedule 40 pipe, Do not recess wrench boss, May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 7: Quick Response Plain Barrel Dry Horizontal Sidewall Sprinkler Top View - Dry HSW Sprinkler Side View - Sprinkler Cover 15610 NOTE: Shown with an Adjustable Standard Dry HSW Sprinkler. The protective cover may also be used with the Adjustable Recessed Press the cover together or Plain Barrel style Dry HSW Sprinkler. until it snaps closed. T�T�I After the sprinkler is installed, carefully place the cover over the dry sprinkler as shown. L—F NOTE: Remove the sprinkler clip and cover before placing the system in service! Figure 8: Dry Horizontal Sidewall Sprinkler Cover Part Number 15610 (shown with an Adjustable Standard Dry HSW Sprinkler) (Optional for temporary use with Viking Dry HSW Sprinklers until finish work is completed around the sprinkler.) Form No. F_031993 19.06.24 Rev 19.1 Page 8 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5-1/8' (130.2 mm)� Seal the clearance space around the sprinkler barrel to avoid Xt Maleakage of air Into the protected area and consequent formation of condensate around the sprinkler frame, which could inhibit operation or cause premature operation. Refer to Figure 10. If humidity and temperature differential causes condensation on the exposed dry sprinkler barrel, consider wrapping the exposed barrel with insulation, foam insulating tape, or equivalent. Install the 1' IN threaded end of the dry sidewall sprink- ler into the 1' NPT outlet of a malleable iron tee fitting per ANSI B 16.3 (Class 150) or cast iron threaded tee fitting per ANSI 16.4 (Class 125) only. Minimum wall opening; diameters 1-3/4' (44.5 mm) Maximum wall opening (Exposed diameter 2-1/4' (57 mm) Barrel) Ambient Exposed Barret Ambient Temperature Temperatureof 40°F/4°C 50°F/10°C 60°F/16°C Area�A at thp Protected Exposed Minimum Barrel Discharge End Lengthx" Face of the of the Sprinkler Tee to the Outer Surface of the Wall In. (mm) In. (mm) In. (mm) 40°F (4°C) 0 0 0 30°F (-1'0 0 0 0 20°F (-7°C) 4 (100) 0 0 10°F (-12°C) 8 (203) 1 (25.4) 0 0°F (-18°C) 12 (305) 3 (76) 0 -10°F (-23°C) 14 (356) 4 (102) 1 (25A) -20°F (-29°C)14 (356) 6 (152) 3 (76) -30°F (-34°C) 16 (406) 8 (203 4 (102) -40°F (-40°C) 18 (457) 8 C203) 4 (102) -50°F C-46°C) 20 (508)10 (254 6 (152) -60°F (-51°C) 120 (508)10 (254 6 (152) jlljlljll------------------- ii ii Deflector at IIIIIIIII____________ii ii Maximum Distance IIIIIIIII------------------- From Wall IIIIIIIII jlljlljll 13/16' Ceiling (20.6 mm) IIIIIIIII IIIIIIIII 4' (102 mm) Minimum 6' (152 mm) Maxlmumx Sleeve finish matches escutcheon 3-1/16' *(15.9 (77.8 mm) m) 3-1/8' (79.4 mr N Minimum 1-1/2' (38.1 mm) diameter Outer Surface of the Wall NOTE, To locate the deflector at the maximum distance from the wall, with no adjustment available, order the standard dry horizontal side - wall sprinkler 1' longer than the "A' dimension. Up to 2' (50.8 mm) adjustment is available. Deflector at Minimum Distance From Wall NOTE: To locate the deflector at the minimum distance from the wall, with no adjustment available, order the standard dry horizontal side - wall sprinkler 1' shorter than the 'A' dimension. (May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. w)KThe protected area refers to the area below the ceiling, The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. wwwThe minimum required barrel length is not the same as the "A" dimension. Refer to Figures 3, 5, and 7 for the 'A' dimension. Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler is Shown) Seal — (or equivalent method) Clearance Opening Insulated Wall Dry Sprinkler Seal on the Exterior of the Wall w uu Dry Sprinkler Seal Within the Wall Figure 10: Dry Sprinkler Seal (Adjustable Standard Dry HSW Sprinkler is Shown) Replaces Form No. F_031993 Rev 15.1.P65 Form No. F_031993 19.06.24 Rev 19.1 (Added patent number.) tqcu TYCOO BlazeMasterO CPVC Pipe & Fittings The dependable choice Peace of mind. That's what you get when you choose TYCO° BlazeMaster° CPVC for your fire sprinkler system. Our broad portfolio of products offered in a wide range of sizes is backed by Johnson Controls' industry -leading 10-year warranty and the BlazeMaster° FBCTm System Compatible Program, the most robust compatibility program in the industry. Choose TYCO° BlazeMaster° CPVC when you want the job done right. Looking to save time and money on the jobsite? Try our new line of TYCO° Rapid Seal sprinkler head adapters. Designed to reduce installation time, the Rapid Seal Adapter's all-CPVC design eliminates the need for thread tape or sealant and provides an easy, leak -free installation. Simply hand -tighten and adjust with a wrench. Turn. Tighten. Done. Learn more at www.tyco-fire.com Looking for faster installations? Rapid Seal Adapter Features: • No thread tape or sealant • No dezincification • Available in various styles Johnson 010 Controls Metal hangers, solvent cement, and other tools CPVC products Pipe Fittings Offered in 3/4" (19,05 mm) up to 3" (76,2 mm) diameters in standard 10ft. (3,05 m) and 15ft. (4,57 m) lengths; limited availability for 8ft. (2,44 m) lengths Broad range of configurations and styles offered in 3/4" (19,05 mm) to 3" (50,8 mm) connections NEW! Rapid Seal Adapter Straight and 90-degree elbow adapters offered in 3/4" (19,05 mm) and 1" (25,4 mm) NPT No need for thread tape or sealant connections; spigot adapter offered in 1" (25,4 mm) NPT connection Accessories CPVC Compatibility Understanding CPVC compatibility is extremely important when installing your residential sprinkler system. To ease the burden associated with researching and selecting accompanying construction products, Lubrizol developed the FBCTm System Compatible Program. FBG SYSTEM COMPATIBLE Customer Service: Tel: 800.558.5236 Fax: 800.877.1295 Technical Service: Tel: 800.381.9312 Fax: 800.791.5500 www.tyco-fire.com © 2019 Johnson Controls. All rights reserved. (E)POTTER h The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4" box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6", 8" and 10" sizes Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Size inches (mum) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC PDC-6-12 1750500 200mA 96 76 8 (200) 12VDC PDC-8-12 1750502 .200mA 96 77 10 (250) 12VDC PDC-10-12 1750504 .200mA 96 78 6 (150) 1 24VDC PDC-6-24 1750501 .20mA 95 77 8 (200) 24VDC PDC-8-24 1750503 20mA 83 79 10 (250) 24VDC PDC-10-24 1750505 20mA 85 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. BELLS PBA AC & PDC-DC APPROVED * ULC on PDC-DC Only ** FM on PBA-AC Only Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non -corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note 1) Environmental -400 to 150OF (-400 to 66°C) Limitations (Outdoor use requires weatherproof backbox.) AC Bells - 4 No. 18 AWG stranded wires Termination DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. �AWARNIN� Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. WARNIN In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 1 OF 2 (E)POTTER BELLS The Symbol of Protection PBA AC & PDC-DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions WARNING Inches (mm) Wtoinstaller down will prevent bell froWringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) _ Fig 1 53/4" _ (146 mm) 10" (250 mm) 8„ r - I (200 mm) 6" j I5/8" (150 mm) I I 211/16" (68 mm) DWG#776-1 Wiring Rear View Fig 3 D,C. BELLS (OBSERVE POLARITY) A,C, BELLS (86 mm) 4 1/4" (108 mm) 3 3/8" 5" (86 mm) (127 mm) RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) O O FROM CONTROL PANEL CBLIACK EXT BELL FROM CONTROL PANEL OR D-OF-LINE OR PRECEDING BELL SISTOR PRECEDING BELL BLACK (IN) OT) BLACK (IN) O CBLACK CAUTION - WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN, NOTES: CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 2 OF 2 ARGCO FIRE SPRINKLER SPARE HEADBOXES Heavy gauge steel construction 3 Head Box 12 Head Box (65-10-152) Knockouts and shelf to accommodate any 1/2" or 6 Head Box 3/4" sprinkler head All -welded construction and full length hinge Red powder coated finish Slotted for easy mounting with screws, rivets or strapping (65-10-151) (65-10-150) 6 Large Head Box (65-10-151 A) The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Two Hole Standoff Hanger and Restrainer Fig.188R (Formerly Afcon Fig. 514) Size Range: 3/4" through 2" Material: Carbon Steel Finish: Pre -Galvanized per ASTM A653 Service: Hanger and surge restraint for horizontal CPVC, steel, and copper piping when installed on the top, bottom, and side of the supporting structure. Guide for vertical CPVC, steel, and copper piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. Easily attaches to wood structure with #10 x T' hex washer head self -threading screw supplied with product. No pre -drilling required. • Bottom of pipe is offset 172" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger& Restrainer Hangs Restr; 4c ner V,ASC,. kk:p Engineered Solutions us tallation - Backing Nut iger =1 - At top fastener traint = 2 - On each fastener NFPA-13Dand NFPA-13R ANVIL, An ASC Engineered Solution PROJECT INFORMATION APPROVAL STAMP Project: ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SS-9.18 page 1 SS-SUB-188R-v0120220629 Two Hole Standoff Hanger and Restrainer (cont.) Fig.188R (Formerly Afcon Fig. 514) Hanger and Restrainer Fig.188R: Dimensions (in) • Weight (Lbs) CPVC A B 0C D E F Pipe Size PPPF" ASC / Engineered Solutions 0 G Max. Hanger Approx. Spacing (ft) Weight/100 (lbs) 3A 23/4 31/2 1/4 2 1 2% 11/2 5 /2 11 1 213/16 3'h 'A 23/16 1 21 A6 Th 6 12 TA 213/16 31/2 'A 25/16 1 31/4 Th 6/2 13 11/2 35/8 4'/4 1/4 2716 1 31/2 11/2 7 14 2 3"A6 43/8 'A 2"/16 1 4 Th 8 16 Pipe CPVC Steel & Copper SS-9.18 Fig.18BR: Listed Fasteners Wood and Composite Beams Screw Supplied or #10 x T' TEK Screw #14 x T' TEK Screw or'/V x 11/2" Lag Screw Steel (18ga. Minimum) #14 x 1" TEK Screw or 1/4" x T' TEK Screw #14 x 1" TEK Screw or W' x T' TEK Screw ANVIL An ASC Engineered Solution page 2 SS-SUB-188R-v0120220629 9:,ASC kk:p Engineered Solutions Two Hole 900 Side Mount Strap Fig.187 (Formerly Afcon Fig. 511) Size Range: 3/d'through 2" i Finish: Zinc Plated Steel (Hot -Dip Galvanized optional) Service: Hanger for CPVC pipe in the horizontal position on the bottom of structural wood beams and Steel20 Ga. (min.) (Fig. A). Can be used as a restrainer, only in Steel20 Ga. (min) (Fig. B). During installation, adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger, minimizing vertical pipe movement. Approvals: UL and ULC Listed. Installation: • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. Do not anchor tightly to mounting surface. Pipe must be allowed to move freely through hanger. Steel applications require two (2) #14 x 1" hex washer head self -drilling TEK screws. Not Supplied. Part Number STD-0090. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x T' hex washer head self threading screw supplied with product. No pre -drilling required. Ordering: Specify CPVC pipe size, figure number and description. — A — 0C -� r F —E� Fig. A Fig. B Fig.187: Dimensions (in) • Weight (lbs) CPVC A B 0C E F Max. Hanger Pipe Size Spacing (ft.) 'A "/16 11/2 3/16 13/16 21/2 51/2 1 1 19/16 3/16 13/16 23/4 6 Th V/16 13A 3/16 13/16 YA 61/2 Th V/16 111/16 3/16 13/16 Th 7 2 19/16 21/8 3/16 13/16 313/16 8 c @us LISTED Approx. Weight/100 (lbs) 5 6 7 8 9 PROJECT INFORMATION APPROVAL STAMP Project: I I ❑ Approved Address: ❑ Approved as noted Contractor: ❑ Not approved Engineer: I Remarks: Submittal Date: Notes 1: Notes 2: SS-11.19 page 1 SS-SUB-187-v0120220526 (E)POTTER A The Symbol of Protection Features • Pre -assembled and pressure tested • Available in 1",1 1/4", 1 1/2", & 2" nominal pipe size models • Female adapter ships loose so riser can be installed in a confined space • Fits in standard 2X4 construction walls • Includes 3 way valve to allow for calibration of pressure gauge AWARNING • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Description The RD13 Riser (with NPT connectors) is constructed from Listed CPVC products suitable for fire sprinkler services subject to the limitations and installation requirements of Flameguard® CPVC pipe and Spears® CPVC fittings. The RD13 Riser incorporates a VSR-SG flow switch, gauge, and drain/test valve. The VSR-SG flow switch is equipped with union connection to facilitate the installation and removal of the switch in confined spaces. Installation 1. Using appropriate sealant, thread the female adapter on to the main water supply. Then glue the riser assembly to the female adapter. Pipe the drain connection to an adequate drain location capable of handling the drain discharge. The riser can be mounted in the horizontal or vertical position. Direction of flow is indicated in Fig. 1. The waterflow switch must be located on the top or on the side of the pipe when installed in the horizontal position. This will prevent debris from entering the throat of the waterflow switch which could interfere with proper operation. 2. Following CPVC manufacturer's instructions for preparation and gluing of CPVC piping systems, glue the main riser to the main supply line for the sprinkler heads. NOTE: All glued connections must be completed and cured before the flowswitch is installed. (Continued on page 2). A CAUTION Do nrmayause e union nut, hand tighten only. Use of a wrenma damageto the union nut. RD13 Residential Riser W Flow Switch Technical Specifications Dimensions See Fig 2 Service Pressure 175 PSI (12,07 BAR) Flow Sensitivity 4-10 GPM (15-38 LPM) - UL Range for Signal Maximum Surge 18 FPS (5.5 m/s) Two sets of SPDT (Form C) Contact Ratings 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 m Amps min. at 24V DC Resistive Environmental Temperature range: 40°F-120°F (4.5°C-49°C) Limitations Conduit Entrances Two knockouts provided for 1/2" conduit Specifications subject to change without notice Service Use Automatic Sprinkler NFPA- 13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 British Standard BS9251 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401152 - REV M • 6/20 PAGE 1 OF 3 (E)POTTER The Symbol of Protection Installation (Continued) RD13 Residential Riser 3. A thread sealant shall be used in making threaded connections. Teflon® thread tape is the recommended sealant. Some thread sealants other than Teflon thread tape contain solvents or other materials that may be damaging to CPVC. For other types of thread sealants, which have been specifically investigated and confirmed to be "System Compatible", refer to www.spearsmfg.com. Attach gauge to riser. Apply Teflon® tape to male fitting of gauge only. See Fig 1. 4. Check to make sure the proper paddle is installed on the switch. (Paddle size must match the riser pipe size and Tee manufacture.) 5. Install the flow switch to the RD13 Riser. Verify that the o-ring is properly positioned in its groove. Hand tighten the nut to the union after orienting the flow switch in the appropriate direction to detect waterflow. The paddle must not rub the inside of the Tee or bind in any way. The stem should move freely when operated by hand. See Fig. 1. NOTE. Do not leave switch cover off for an extended period of time. 6. The side of flow switch must be perpendicular with the riser piping. See Fig. 3. Testing The frequency of inspection and testing for the Model VSR-SG and its associated protective monitoring system, should be in accordance with applicable Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently.) If provided, the inspector's test valve (usually located at the end of the most remote branch line) should be used for test purposes. If there is no remote inspection test connection; a short length of hose may be connected to the discharge of the 1" drain line valve, or if the drain line is connected to a drain such as a slop sink or storm drain that will sufficiently handle the discharge of the main drain valve. The drain valve can be used to test the operation of the VSR-SG switch. A minimum flow of 10 GPM (38 LPM) is required to activate this switch. An orifice equal to the smallest sprinkler head orifice used in the system shall be attached to the drain line for testing purposes. Maintenance The VSR-SG waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock number 1029030. There is no maintenance required, only periodic testing and inspection.. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nut on union fitting. • Lift detector clear of pipe. Fig I Optional Cover Tamper Retard Adjustment Switch The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the DO NOT LEAVE minimum required to prevent false alarms. Retard COVER OFF ?� Adjusting —► FOR EXTENDED Knob PERIOD OF TIME Mount so arrow on base points WA ERFOLOWOF ® in direction of \ waterflow 0 1" Male 0 Fitting on DWO, #1063-3 All Sizes Riser may Important: be 1", 1/4", The paddles have raised lettering that show the pipe size and the TEE 1 1/2", or 2" manufacturer they are to be used with. The proper paddle must be used. The paddle must be properly attached and the screw that holds the paddle must be securely tightened. Kati 0 Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401152 - REV M • 6/20 PAGE 2 OF 3 (E)POTTER RD 13 The Symbol of Protection Residential Riser Dimensions (See Chart Below) Fig 2 T NPT Adaptor (Shipped Loose) Orientation Fig 3 3 1/2" Gauge (Shipped Loose) 1" NPT — Drain Valve A CAUTION Flow switch must be properly orientated. Side of cover must be perpendicular with the pipe. Improper orientation could delay or prevent notification of waterfiow. *RD13 Risers (ASSEMBLED DIMENSIONS) Riser Size Model Number Part Number Dimension "A" Dimension `B" Dimension "C' Dimension "D" Dimension "E" Dimension "F" (in) (mm) (in) (mm) (in) (mm.) (in.) (mm) (in) (mm) (in) (mm) 1" RD13-100-1 1119067 19 483 15 3/4 400 18 457 14 5/8 371 12 1/4 311 10 1/2 267 1 1/4" RD13-125-1 1119077 19 5/8 498 16 1/2 419 18 1/2 470 15 3/8 391 12 1/2 318 10 5/8 270 1 1/2" RD13-150-1 1119087 N/A N/A 16 3/4 425 N/A N/A 15 5/8 397 12 3/4 324 10 3/4 273 2" RD13-200-1 1119097 N/A N/A 18 1/4 464 1 N/A I N/A 116 7/8 1429 13 3/8 340 11 1/8 1 283 Ordering Information Ordering Information Nominal Pipe Size Model Part Number 1" RD13 Riser 1119067 1 1/4" RD13 Riser 1119077 1 1/2" RD13 Riser 1119087 2" RD 13 Riser 1119097 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Replacement VSR-G, stock no. 1144460 Gauge, Flow Switch, and NPT Adapter shipped loose in box. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com [so sooi:z01s DESIGNING, MANUFACTURING, & DISTRIBUTING QUALITY SYSTEMS 5401152 - REV M • 6/20 PAGE 3 of 3 ES-A-2000B Series 2000B A M E S Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 1/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • '/2" - 2" (15 - 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • '/2" - 1 " (15 - 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F - 140oF (0.5°C - 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. Job Name Job Location Engineer Approval 2" 2000B HC (50mm) 11� �G 2000E (20mm) Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup- plies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non -potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals �pSSIFj� G c sA0 No,C U� US us 1015 1364.5 %11 - 2" (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 231/2" (594mm) SIZE I DIMENSIONS in. mm A in. mm in. B mm C in. mm F in. mm G in. mm H in. mm in. I mm lbs. kgs. 1/2 15 10 254 4% 117 2'/16 62 5 127 3% 85 2'/16 59 21/6 52 4.5 2 6/4 20 11 Ya 282 4 102 31/6 79 63/ 6 157 31/ 6 87 2Ya 54 16/ 6 33 5 2.3 1 25 131/4 337 1 51/6 130 1 4 102 1 71/2 191 1 3% 85 1 111/6 43 1 111/6 43 1 12 5.4 11/4 32 16% 416 5 127 36/ 6 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 40 161/4 425 47/8 124 31/2 89 91/4 248 51 /16 148 3Ya 79 2" /1 6 68 15.86 7.2 2 50 191/2 495 61/4 159 4 102 13% 340 6'/6 156 3'/6 87 2"/16 68 1 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. H ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) 0 kPa psi '12"(15mm) 3 N 83 12 H 0 69 10 a) (D 55 8 1 ( 3 41 6 N 28 4 aa) 14 2 a 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi N 152 22 J 124 18 i 96 14 7 y 69 10 ai 41 6 14 2 A 31411 (20mm) N N O J 0 N N a1 a AP 0 5 10 15 26 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate N kPa psi A 11 (25mm N 1 N 110 16 ) J N J 83 12 y 69 10 N 3 55 8 N y 41 6 a)a 28 4 d 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate A M E S FIRE & WATERWORKSs A Watts Water Technologies Company kPa psi A 1114" (32mm) 96 14 83 12 69 10 55 8 41 6 28 4 14 2 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 111211 (40mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 APO 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 2" (50mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com ES-A-2000B 1410 © 2014 Ames Fire & Waterworks