Loading...
APPROVED RESUB1 BLD2023-0759+Architectural_Plan+8.21.2023_8.40.36_AM+37363711 2 3 4 5 6 7 8 9 10 SHEET INDEX 11 Y x c� J U m a Q N Cfl v 0 Cl) CV CD N CV W PACIFIC COMMONS HEALTHCARE REALTY 21727 76TH AVE W EDMONDS, WA 98026 PERMIT SET PROJECT NOTES I ABBREVIATIONS I PROJECT TEAM 1. THESE DRAWINGS AND THE ACCOMPANYING SPECIFICATIONS ARE THE PROPERTY OF TGB ARCHITECTS AND ARE NOT TO BE COPIED OR REUSED OWNER: OWNER CONTACT: FOR ANY OTHER PROJECT. JENNIFER GLOECKNER HEALTHCARE REALTY 425-775-4546 2. DRAWINGS HAVE BEEN PREPARED FROM DATA AND DRAWINGS PROVIDED BY THE OWNER TO THE ARCHITECT. THE ARCHITECT HAS VERIFIED 901 BOREN AVENUE, SUITE 1100 JGLOECKNER@HEALTHCAREREALTY.COM EXISTING CONDITIONS TO THE BEST OF THEIR ABILITY. THE ARCHITECT ISSUES NO WARRANTY, NEITHER EXPRESSED NOR IMPLIED, FOR THE SEATTLE, WA 98104 ACCURACY OR COMPLETENESS OF THE INFORMATION INDICATED HEREIN. ARCHITECT: PROJECT LEAD: GINA DAIS 3. NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF EXISTING CONDITIONS THAT ARE CONTRARY TO THOSE REPRESENTED WITHIN THE TGB ARCHITECTS PRINCIPAL IN CHARGE: KENT GREGORY DRAWINGS OR WHERE DIMENSIONS VARY GREATER THAN 2" THAN THOSE SHOWN IN DRAWINGS. 21911 76TH AVE W, SUITE 210 425-778-1530 GDAIS@TGBArchitects.com EDMONDS, WA 98026 4. CONTRACTOR TO COORDINATE REQUIREMENTS FOR INFECTION CONTROL DURING COURSE OF CONSTRUCTION WITH OWNER PRIOR TO COMMENCEMENT OF WORK. GENERAL CONTRACTOR: GENERAL CONTRACTOR CONTACT: 5. ALL PARTITIONS, UNLESS OTHERWISE SHOWN OR DETAILED, WILL BE METAL STUDS OF THICKNESS TO ADEQUATELY COVER PIPING, CONDUITS, ETC. CONTACT NAME GENERAL CONTRACTOR CONTACT PHONE 6. PROVIDE 24" SQUARE ACCESS PANELS OR OF SIZES REQUIRED WHERE PLUMBING AND HEATING VALVES, WATER SWITCHES, OXYGEN PRESSURE GENERAL CONTRACTOR'S ADDRESS CONTACT EMAIL SWITCHES, VENTILATION SPUTTER DAMPERS, ETC. ARE SHOWN ON PLUMBING AND MECHANICAL DRAWINGS. SUCH ACCESS PANELS TO BE GENERAL CONTRACTOR'S ADDRESS INSTALLED IN THE FOLLOWING:A) GWBBOARD CEILINGS) METAL STUD AND MASONRY PARTITIONS. 7. WALL ASSEMBLIES MUST BE MAINTAINED AT ALL RECESSED FIRE EXTINGUISHER CABINETS AND ALL RECESSED EQUIPMENT. 8. PROVIDE FIRE EXTINGUISHER CABINETS OF THE TYPE SPECIFIED. REFER TO FLOOR PLAN(S) FOR LOCATIONS. 9. ALL SHAFT PARTITIONS EXTEND FROM FLOOR SLAB TO UNDERSIDE OF SLAB ABOVE. EXPOSED BEAMS WITHIN SHAFTS ARE TO BE FIREPROOFED WITH 2-HOUR GWBBOARD ENCLOSURE. 10. THE FIRE RATINGS OF ALL FIRE RATED PARTITIONS WILL BE STENCILED ABOVE CEILINGS, EACH SIDE OF PARTITIONS, BOTH SIDES OF CORRIDORS AND AS REQUIRED BY AUTHORITY HAVING JURISDICTION. 11. ALL GWBBOARD IS 5/8" TYPE W UNLESS NOTED OTHERWISE. 12. THE DRAWINGS AND THE SPECIFICATIONS ARE COMPLEMENTARY. WHATEVER IS INDICATED IN ONE IS ASSUMED TO BE INDICATED IN THE OTHER. NOTIFY THE ARCHITECT IN CASE OF DISCOVERED DISCREPANCIES. 13. ALL SUBSTRATES ARE TO BE SMOOTH PRIOR TO INSTALLATION OF FINISHES. 14. ALL WORK AND MATERIALS TO CONFORM TO FACILITY STANDARDS. Approved DFM CMr'�s gulrt South County Fire Date: 08/10/2023 08-10-2023 PLAN REVIEW NOTES: APPROVED DFM BURT VICINITY MAP a D ; Aparlme-n-t's-V a $� 21 ath St SW 210th St SW F 9 212th St SW ^Edmonds-Woodway / High School0 212th St sw c a r'.1 f�Q n Southwest Recycling a & Transfer Station 215th St SW Chase Lake Elementary School f 21 eth St SW v 220th St IE sw f 224th St SW �sco St Sw p ti 216thStSW - 2161hS' Lakeside 21727 76th Ave W., Apartment Hom •Edmonds, WA 98026 QPremera Blue Cross Q 6 min walk - wci Brig 2181h St SW 218th $t SW QWork 21 mn St sw Prometric Testing Center Q Cyrinwood Honda 0 P n p zzznds,sw 0ic Viev✓ ArenaEsperance Q 222nd St SW Park & 9e s Off Leash Dog Area s 22411 sr sw aP 224th St SW 99 Ranch Mar, 3 3 s oogle r City Of Edmonds r1Te rTt- Work EXTERIOR STAIR REMOVAL Address 21707 76TH AVE W --------------------- - - - - - -------------------- ---------------------------------------------------------------------- Owner PACIFIC COMMONS - ----------------------------------------------------------- , -------------------------------------------- Approved Date 08/21 /2023 ------------------------------------ Building Official' rrv.L e , P,n J4-0 Je Permit Number BLD2023-0759 ------------------------------------- REVISIONS DATE PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 GENERAL G0.00 G0.21 ARCHITECTURAL A1.01 A1.02 COVER SHEET LIFE SAFETY PLANS DEMO / FLOOR PLAN - LEVEL 1 DEMO / FLOOR PLAN - LEVEL 2 PROJECT INFORMATION SCOPE OF WORK REMOVAL OF EXISTING EXTERIOR STAIR AND REPLACEMENT OF SECOND FLOOR RAILING LEGAL DESCRIPTION SOLNERS 5 ACRE TRACTS BLK 000 D-01 - S 189.62FT OF W 270.03FT OF TR 27EXC THE S 15SF THOF FOR RD TAX PARCEL NUMBER 00580700002701 AUTHORITY HAVING JURISDICTION (AHJ) CITY OF EDMONDS APPLICABLE CODES BUILDING CODE: WA STATE BUILDING CODE (IBC WITH AMENDMENTS) - 2018 EXISTING BUILDING CODE: WA STATE EXISTING -BUILDING CODE (IEBC WITH AMENDMENTS) - 2018 ENERGY CODE: WA STATE ENERGY CODE (IECC WITH AMENDMENTS) - 2015 LIFE SAFETY CODE: NFPA 101 2012 FIRE CODE: INTERNATIONAL FIRE CODE (IFC) - 2015 MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE (IMC) - 2015 PLUMBING CODE: UNIFORM PLUMBING CODE (UPC) - 2015 ELECTRICAL CODE: NATIONAL ELECTRICAL CODE (NEC) - 2014 ACCESSIBILITY CODE: ANSI A117.1 2009 (BY REFERENCE FROM IBC AND WSBC) DEFERRED SUBMITTALS 1. MECHANICAL 2. PLUMBING 3. ELECTRICAL 4. FIRE SUPPRESSIONS SYSTEM 5. FIRE ALARM 6. SPECIAL INSPECTIONS (REPORTS) ALTERNATES NONE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com 3626 REGISTERED I ECT L. KENT GREGOR STATE OF WASHINGTON PACIFIC COMMONS 21727 76TH AVE W EDMONDS, WA 98026 PERMIT SET RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT COVER SHEET PROJECT INFORMATION PROJECT NUMBER: 23004 PROJECT LEAD: GD DRAWN BY: AP 1 2 3 4 5 6 7 8 9 10 11 SHEET NO GOmOO 1 1 2 3 4 5 1 6 7 8 9 10 11 x 0 w C ? 0 1 VEEA� a LEVEL 2 - LIFE SAFETY 1 /8" = 1'-0" EXIT ON GRADE LEVEL 1 - LIFE SAFETY 1 1 /8" = 1'-0" 1 EXIT ON GRADE CODE ANALYSIS - OUTPATIENT CLINIC - TENANT IMPROVEMENT - DRAFT 2018 WA STATE BUILDING CODE (REF IBC-2018) EXISTING BUILDING INFORMATION B-BUSINESS VB 2-STORIES + PARKING LEVEL (BASEMENT) EXISTING BUILDING -MAIN OCCUPANCY PER RECORD DWGS EXISTING BUILDING -CONSTRUCTION TYPE EXISTING BUILDING NUMBER OF STORIES EXISTING BUILDING - SPRINKLERED? PER RECORD DWGS PER RECORD DWGS PER RECORD DWGS YES, COMPLYING WITH WSBC SECTION 903.3.1 OCCUPANCY AND USE MAIN (PREDOMINANT) OCCUPANCY/OCCUPANCIES OUTPATIENT CLINIC SPACES (INCLUDING RELATED BUSINESS SPACES) FLOOR ONE -------- -------- -------- GROUP B - BUSINESS (10394SF) CHAPTER 3 SECTION 304 OUTPATIENT CLINIC SPACES (INCLUDING RELATED BUSINESS SPACES) FLOOR TWO GROUP B - BUSINESS (8509SF) FIRE -RATING FOR BUILDING ELEMENTS, FIRE AND SMOKE PROTECTION FEATURES PRIMARY STRUCTURAL FRAME CHAPTER 6 CHAPTER 7 SEE ALSO "MEANS OF EGRESS" SECTION BELOW TABLE 601 0 HOURS AT CONSTRUCTION TYPE V-B INTERIOR BEARING WALLS TABLE 601 0 HOURS AT CONSTRUCTION TYPE V-B INTERIOR NON -BEARING WALLS AND PARTITIONS TABLE 601 0 HOURS AT CONSTRUCTION TYPE X-X FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS TABLE 601 0 HOURS AT CONSTRUCTION TYPE V-B ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS TABLE 601 X HOURS AT CONSTRUCTION TYPE V-B SHAFT ENCLOSURES ELEVATOR LOBBY ENCLOSURES SECTION 713.4 2-HR OR 1-HR DEPENDING ON NUMBER OF CONNECTED FLOORS, BUT NOT LESS THAN 2-HR WHEN FLOOR CONSTRUCTION IS 2 HR. SECTION 3006.2 NOT REQUIRED IN B-OCCUPANCY, WHERE SPRINKLERED, UNLESS CORRIDORS ARE REQUIREDTO BE FIRE -RESISTIVE RATED. STAIR ENCLOSURES SECTION 1023.2 2-HR OR 1-HR DEPENDING ON NUMBER OF CONNECTED FLOORS, BUT NOT LESS THAN 2-HR WHEN FLOOR CONSTRUCTION IS 2 HR. MEANS OF EGRESS CHAPTER 10 -------- OCCUPANT LOAD SECTION 1004 -------- BUSINESS AREAS FLOOR ONE TABLE 1004.5 10,394 SF / 1 OCCUPANT PER 150 SF GROSS = 70 OCCUPANTS BUSINESS AREAS FLOOR TWO TABLE 1004.5 8,509SF / 1 OCCUPANT PER 150 SF GROSS = 57 OCCUPANTS PROJECT OCCUPANT LOAD TOTAL OCCUPANT LOAD = 127 OCCUPANTS SUM OF ABOVE NUMBER OF EXITS REQUIRED - MINIMUM SPACES WHERE ONE EXIT IS ALLOWED COMMON PATH OF TRAVEL (ALLOWABLE) ARRANGEMENT OF EXITS OR EXIT ACCESS DOORS SECTION 1006.2.1 TABLE 1006.3.2 2 (FOR OCCUPANT LOAD NO GREATER THAN 500) SEE ALSO "ONE EXIT ALLOWED" SECTION BELOW IN SPRINKLERED GROUP B SPACES WITH NO MORE THAN 49 OCCUPANTS AND NO MORE THAN 100 FT COMMON PATH OF TRAVEL 100 FT IN GROUP B, WHEN SPRINKLERED PLACED AT A DISTANCE FROM ONE ANOTHER NOT LESS THAN ONE-THIRD THE DISTANCE OF THE MAXIMUM DIAGONAL OF THE SPACE SERVED IN A SPRINKLERED BUILDING SECTION 1006.3.3 TABLE 1006.2.1 TABLE 1006.3.3 2 TABLE 1006.2.1 SECTION 1007.1.1 EXIT ACCESS TRAVEL DISTANCE (ALLOWABLE) SECTION 1017 TABLE 1017.2 300 FT IN GROUP B, WHEN SPRINKLERED CORRIDOR CONSTRUCTION TABLE 1020.1 UNRATED IN OCCUPANCY GROUP B, WHEN SPRINKLERED CORRIDOR (ALLOWABLE) DEAD END LENGTH IN ROOMS OR SPACES REQUIRING MORE THAN 1 EXIT OR EXIT -ACCESS DOOR DOOR TYPES ALLOWED DOOR SWING PANIC HARDWARE SECTION 1020.4 50 FT IN OCCUPANCY GROUP B, WHEN SPRINKLERED SECTION 1010.1.2 SWING TYPE DOORS. POWER -OPERATED DOORS. MANUALLY - OPERATED SLIDING DOORS SERVING AN OCCUPANT LOAD NOT EXCEEDING 10. DOOR MUST SWING IN THE DIRECTION OF EGRESS TRAVEL WHEN SERVING A SPACE WITH AN OCCUPANT LOAD OF 50 OR MORE SECTION 1010.1.2.1 SECTION 1010.1.9.4 SECTION 1010.1.10 REQUIRED WHERE SERVING GROUP A OCCUPANCY WITH AN OCCUPANT LOAD OF 50 OR MORE. GROUP A HAVING AN OCCUPANT LOAD OF 300 OR LESS AND GROUP B MAY HAVE KEY OPERATED LOCKING DEVICES ON EGRESS SIDE OF MAIN DOOR(S) PROVIDED IT HAS READILY -DISTINGUISHABLE LOCKING HARDWARE AND RELATED SIGNAGE. LIFE SAFETY PLAN SYMBOLS AREA OF WORK NOT IN SCOPE COMMON PATH OF TRAVEL TOTAL TRAVEL DISTANCE EXIT ACCESS ARROW EXIT ARROW tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PACIFIC COMMONS 21727 76TH AVE W EDMONDS, WA 98026 PERMIT SET RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LIFE SAFETY PLANS 155UANUL No. Description Date 1 PERMIT & BID SET 04/05/2023 2 PERMIT COMMENTS 07/28/2023 PROJECT INFORMATION PROJECT NUMBER: 23004 PROJECT LEAD: GD DRAWN BY: AP SHEET NO Z PA 3 4 5 6 7 8 9 10 11 1 1 2 3 1 4 5 6 7 8 4 10 DEMOLITION NOTES 11 1. DEMOLITION PLANS REPRESENT EXISTING CONDITIONS. THEY ARE INTENDED FOR REFERENCE ONLY. THESE PLANS ARE NOT INTENDED TO BE A DESCRIPTION OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED THROUGH DURATION OF WORK. tgb architects Y x a ILL w U C0 a LEVEL 1 - NEW 1 /8" = 1'-0" 3. SEE CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 4. ALL OPENINGS IN SLABS, ROOFS, WALLS, CEILINGS, AND PARTITIONS CREATED BY PROJECT -RELATED DEMOLITION OR BY NEW CONSTRUCTION SHALL BE SEALED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 5. ALL OPENINGS IN EXTERIOR WALLS, EXTERIOR SOFFITS, AND ROOFS CREATED BY PROJECT -RELATED DEMOLITION OR NEW CONSTRUCTION SHALL BE CLOSED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, THERMAL INSULATION, WEATHER PROTECTION, WATER -PROOFING, VAPOR -RETARDATION, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW CLADDINGS AND FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 6. REPLACE OR REPAIR ALL FIREPROOFING REMOVED OR DAMAGED DURING DEMOLITION OR CONSTRUCTION, SO AS TO MAINTAIN THE FIRE -RATING OF EXISTING BUILDING ELEMENTS. 7. THE OWNER WILL REMOVE ALL EXISTING MEDICAL EQUIPMENT FROM THE AREA OF WORK PRIOR TO TURNING THE SPACE OVER TO THE CONTRACTOR. NOTIFY THE OWNER OF ANY MEDICAL EQUIPMENT REMAINING IN THE SPACE. 8. CONSULT WITH THE OWNER PRIOR TO DEMOLITION ABOUT MATERIALS INDICATED TO BE SALVAGED FOR THE OWNER'S USE, BUT NOT INTENDED FOR RE -USE ON THIS PROJECT. STORE ALL SUCH MATERIALS UNTIL THE OWNER CAN TAKE POSSESSION. 9. ANY MATERIALS AND EQUIPMENT INDICATED IN DRAWINGS TO BE SALVAGED AND REUSED ON THIS PROJECT TO BE STORED BY CONTRACTOR UNTIL SCHEDULED REINSTALLATION. CONSULT WITH OWNER IF LOCATION INTENDED FOR STORAGE IS IN SPACES BELONGING TO THE OWNER BUT NOT IN THE AREA OF WORK. 10. STABILIZE ANY EXISTING -TO -REMAIN BUILDING COMPONENTS THAT BECOME UNBRACED DUE TO SELECTIVE OR PARTIAL DEMOLITION. PROVIDE A SOUND PERMANENT STRUCTURE PER CODE. 11. PATCH AND REPAIR ALL EXISTING WALLS & FLOORS AFFECTED BY DEMOLITION TO MATCH ADJOINING FINISHES. FLOOR PLAN NOTES 1. FLOOR PLANS MAY NOT INCLUDE TOTAL OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. SECURE NEW WALLS TO SUBSTRATE WITH FASTENERS LOCATED 2' FROM EACH END AND SPACED A MAXIMUM OF 16" O.C. 3. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR ANY CABINETS, EQUIPMENT, HANDRAILS, OR WHERE REQUIRED. 4. LOCATE ALL NEW DOORS 6" FROM HINGE SIDE OF ADJACENT WALL UNLESS NOTED OTHERWISE. 5. ALIGN NEW WALLS WITH ADJACENT EXISTING WHERE APPLICABLE FOR A SMOOTH, CONTINUOUS FINISH. 6. ADD COLUMN FURRING WITH 7/8" FURRING STRIPS & (1) LAYER OF 5/8" GWB EXTENDED TO 6" ABOVE CEILING AT ALL EXPOSED COLUMNS UNLESS NOTED OTHERWISE.. 7. ALL PARTITIONS SCHEDULED TO RECEIVE ACOUSTICAL INSULATION SHALL BE CONSIDERED ACOUSTICAL PARTITIONS AND SHALL BE CONSTRUCTED AND CAULKED AS SPECIFIED. t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PACIFIC COMMONS 21727 76TH AVE W EDMONDS, WA 98026 PERMIT SET RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DEMO / FLOOR PLAN - LEVEL 1 ISSUANCE No. Description Date 1 PERMIT & BID SET 04/05/2023 PROJECT INFORMATION PROJECT NUMBER: 23004 PROJECT LEAD: GD DRAWN BY: AP Q N v 0 Cl) CV O CV N 00 LEVEL 1 - DEMO 1 /8" = V-0" 1 2 3 4 5 6 7 8 7 10 11 SHEET NO 2=:: ew Al mOl O 1 1 2 3 1 4 5 1 6 7 1 8 9 10 DEMOLITION NOTES 11 Y M. 0 ILL G c.� In a LEVEL 2 - NEW 1 /8" = V-0" 1. DEMOLITION PLANS REPRESENT EXISTING CONDITIONS. THEY ARE INTENDED FOR REFERENCE ONLY. THESE PLANS ARE NOT INTENDED TO BE A DESCRIPTION OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED THROUGH DURATION OF WORK. 3. SEE CONSULTANT DRAWINGS FOR ADDITIONAL DEMOLITION REQUIREMENTS. 4. ALL OPENINGS IN SLABS, ROOFS, WALLS, CEILINGS, AND PARTITIONS CREATED BY PROJECT -RELATED DEMOLITION OR BY NEW CONSTRUCTION SHALL BE SEALED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 5. ALL OPENINGS IN EXTERIOR WALLS, EXTERIOR SOFFITS, AND ROOFS CREATED BY PROJECT -RELATED DEMOLITION OR NEW CONSTRUCTION SHALL BE CLOSED AS NECESSARY TO MAINTAIN FIRE -RATING, ACOUSTICS, THERMAL INSULATION, WEATHER PROTECTION, WATER -PROOFING, VAPOR -RETARDATION, INTENDED FUNCTION, AND FITNESS TO RECEIVE NEW CLADDINGS AND FINISHES. ALL MATERIALS DISPLACED TO ACCOMMODATE DEMOLITION SHALL BE REINSTALLED IN LIKE CONDITION OR SHALL BE REPLACED WITH LIKE/SIMILAR MATERIALS AS NECESSARY TO MAINTAIN THE PROPERTIES LISTED ABOVE. 6. REPLACE OR REPAIR ALL FIREPROOFING REMOVED OR DAMAGED DURING DEMOLITION OR CONSTRUCTION, SO AS TO MAINTAIN THE FIRE -RATING OF EXISTING BUILDING ELEMENTS. 7. THE OWNER WILL REMOVE ALL EXISTING MEDICAL EQUIPMENT FROM THE AREA OF WORK PRIOR TO TURNING THE SPACE OVER TO THE CONTRACTOR. NOTIFY THE OWNER OF ANY MEDICAL EQUIPMENT REMAINING IN THE SPACE. 8. CONSULT WITH THE OWNER PRIOR TO DEMOLITION ABOUT MATERIALS INDICATED TO BE SALVAGED FOR THE OWNER'S USE, BUT NOT INTENDED FOR RE -USE ON THIS PROJECT. STORE ALL SUCH MATERIALS UNTIL THE OWNER CAN TAKE POSSESSION. 9. ANY MATERIALS AND EQUIPMENT INDICATED IN DRAWINGS TO BE SALVAGED AND REUSED ON THIS PROJECT TO BE STORED BY CONTRACTOR UNTIL SCHEDULED REINSTALLATION. CONSULT WITH OWNER IF LOCATION INTENDED FOR STORAGE IS IN SPACES BELONGING TO THE OWNER BUT NOT IN THE AREA OF WORK. 10. STABILIZE ANY EXISTING -TO -REMAIN BUILDING COMPONENTS THAT BECOME UNBRACED DUE TO SELECTIVE OR PARTIAL DEMOLITION. PROVIDE A SOUND PERMANENT STRUCTURE PER CODE. 11. PATCH AND REPAIR ALL EXISTING WALLS & FLOORS AFFECTED BY DEMOLITION TO MATCH ADJOINING FINISHES. FLOOR PLAN NOTES 1. FLOOR PLANS MAY NOT INCLUDE TOTAL OF ALL REQUIRED WORK. REFER TO CONSULTANT DRAWINGS FOR POTENTIAL WORK IN OTHER AREAS. 2. SECURE NEW WALLS TO SUBSTRATE WITH FASTENERS LOCATED 2' FROM EACH END AND SPACED A MAXIMUM OF 16" O.C. 3. PROVIDE BLOCKING IN WALLS AS REQUIRED FOR ANY CABINETS, EQUIPMENT, HANDRAILS, OR WHERE REQUIRED. 4. LOCATE ALL NEW DOORS 6" FROM HINGE SIDE OF ADJACENT WALL UNLESS NOTED OTHERWISE. 5. ALIGN NEW WALLS WITH ADJACENT EXISTING WHERE APPLICABLE FOR A SMOOTH, CONTINUOUS FINISH. 6. ADD COLUMN FURRING WITH 7/8" FURRING STRIPS & (1) LAYER OF 5/8" GWB EXTENDED TO 6" ABOVE CEILING AT ALL EXPOSED COLUMNS UNLESS NOTED OTHERWISE.. 7. ALL PARTITIONS SCHEDULED TO RECEIVE ACOUSTICAL INSULATION SHALL BE CONSIDERED ACOUSTICAL PARTITIONS AND SHALL BE CONSTRUCTED AND CAULKED AS SPECIFIED. tgb architects t 425.778.1530 21911 76th Ave W. Ste 210 f 425.774.7803 Edmonds WA 98026 info@tgbarchitects.com www.tgbarchitects.com PACIFIC COMMONS 21727 76TH AVE W EDMONDS, WA 98026 PERMIT SET RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DEMO / FLOOR PLAN - LEVEL 2 ISSUANCE No. Description Date 1 PERMIT & BID SET 04/05/2023 PROJECT INFORMATION PROJECT NUMBER: 23004 PROJECT LEAD: GD DRAWN BY: AP Q N co v 0 M CV O N N co LEVEL 2 - DEMO 1 /8" = 1'-0" 1 2 3 4 5 6 7 1 8 9 10 11 SHEET NO Al m02 Z z 1 PARTIAL SECOND FLOOR FRAMING PLAN n 3/16" = 1'-0" I V EXISTING NEW NEW EXISTING DBL TOP PL (0 M 2 ROWS OF 10d NAILS AT 6" OC NEW STUDS TO EXISTING STUDS (E) GLB PER PLAN n ELEVATION 1/2" = 1'-0" WOOD CAP U _O N E E c/) N O U ?j O .N- DBL TOP PL 00 U U 0 rn m W/10dAT6"OC"PL Q' Q 2 TO PL" (TYP) t �: E cfl co U) � - 2x4 AT 12" OC STUD ° PARAPET WALL (TYP) i N LU 9 i0 X Q � SHEATHING PER O cy) cy) O T � ARCHT (TYP) 8d NAIL AT 6"OC AT TOP 00 AND BOT PL AND TO STUDS 2 1/2" N N 2x4 SILL PL W/ (2) 1/4" X 6" LONG SDS HEAVY DUTY SCREWS AT 8" OC STAGGERED SILL PL W/ (2) 1/4" X 6" VG SDS HEAVY DUTY REWS AT 8" OC SHEATHING � PLAN AT 12" OC STUD �APET WALL (TYP) SECTION 3/4 = 1 0 (E) SHEATHING PER PLAN u PS M a' w w z_ C� E (E) JOIST o 0 IPER PLAN Iz W'0 Z NP c � Q O 'm (E) GLB PER PLAN N N3 0 z0 o (4 aZ'oa U ��10 I IL Nwa� BLD2023-0759 RECEIVED Jun 23 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U) Z J OJ U) Q 3:O J_ ~ LL LLI G z U) O Q a- Q Q(-D 0 �z a_< wQ L LL z v a a 10 N 00 LLI O Q Q S (0 Q I� Z c\IO N Q w DATE: 06/15/23 DWN.: SMV S1.0