APPROVED BLD BLD2024-0153+Architectural_Plan+2.4.2024_3.20.46_PM+4038725STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE GENERAL ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. DESIGN LOADS CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION DEAD LOADS: OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. ROOF 15 PSF CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL LIVE LOADS: PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. ROOF (SNOW LOAD) 25 PSF RESIDENTIAL 40 PSF CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS STATEMENT OF SPECIAL INSPECTIONS ONLY WILL NOT SATISFY THIS REQUIREMENT. SPECIAL INSPECTIONS ARE NOT REQUIRED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work ------------------ REMODEL --- ----------------------------------------------- Address 1027 WALNUT Owner ______________________ __: GARDNER-BROWN -------------- Approved Date -------------- 2/16/2024 ------------- Building Official Permit Number BLD2024-0153 DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. LEGEND DEFINITION SYMBOL DEFINITION SYMBOL DIRECTION OF I I m I m I m I m I r NATIVE SOIL FRAMING EXTENT OF 10GRANULAR FILL FRAMING COLUMNS 0 0 STRUCTURAL STEEL P COLUMN BEARING RATED SHEATHING ON BEAM 0 SHEAR WALL BEAM CONTINUOUS OVER SUPPORT (SEE SCHEDULE) SWX COLUMN MARK CONCRETE WALL (SEE SCHEDULE) BEARING STUD FOOTING MARK O WALL (SEE SCHEDULE) NON -BEARING �HOLDOWN MARK STUD WALL (SEE SCHEDULE) BEARING STUDVV HANGER MARK O SHEAR WALL (SEE SCHEDULE) NON -BEARING FLAG NOTE STUD SHEAR WALL (SEE PLAN NOTES) STEEL MOMENT CMU WALL �V FRAME CONN. ABBREVIATIONS (A) AB ABOVE ANCHOR BOLT ALTERNATE ARCHITECT HORIZ HORIZONTAL KING POST KIPS PER SQUARE INCH MECHANICAL MOMENT FRAME NEAR SIDE ON CENTER KIP ALT KSI ARCH MECH (B) BELOW MF BLKG BLOCKING BEAM BOTTOM BETWEEN COMPLETE JOINT PENETRATION CLEAR NS BM OC BOT BTWN CJP CLR OPP OPPOSITE PLATE PLACES POUNDS PER SQUARE INCH PL PLCS PSI CMU CONCRETE MASONRY UNIT PSF POUNDS PER SQUARE FOOT COL COLUMN P/T POSTTENSIONED CONC CONCRETE PT PRESSURE TREATED REINFORCING CONN CONNECTION REINF CONT CONTINUOUS DOUBLE REQ'D REQUIRED DBL DET SCHED SCHEDULE SIMILAR SLAB ON GRADE STANDARD SHEAR WALL TOP OF CONCRETE DETAIL SIM DIM EA DIMENSION SOG EACH STD ELEV ELEVATION SW EXIST EXISTING TOC EXP FLR EXPANSION FLOOR TOS TOP OF STEEL TOP OF WALL TOW FDN FTG FOUNDATION FOOTING FAR SIDE FULL HEIGHT GLUE -LAMINATED BEAM TYP TYPICAL LINO UNLESS NOTED OTHERWISE FS FH VFY VERIFY VERIFY IN FIELD VIF GLB VERT VERTICAL C G ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09/ A123 m m W Q C) rn 00 011 DESIGN: BTJ DRAWN: JEG CHECK: CMJ JOB NO: 22225.10 DATE: 04/ 1 8/23 RECEIVED Feb 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LLI U 0 LzLI 0 L LI 0 ~ w O O W N O z z � 00 0) J Ora Q W z ZD I _ Q o U w � z z � o � o N :2 Q O 0 � Lli 0 w cn T­ SHEET: S1.1 PARTIAL ROOF FRAMING PLAN SCALE: 1/4" = V-0" 2'-0" 0 2'-0" TYPICAL ROOF FRAMING PLAN NOTES: 1. WALLS SHOWN ON ROOF FRAMING PLAN ARE WALLS BELOW ROOF FRAMING. 2. STUD WALL FRAMING SHALL BE 2x HF STUDS @ 16" OC FOR ALL STUD WALLS SHOWN ON THE PLAN. 3. REFER TO SHEET S3.1 FOR TYPICAL ROOF FRAMING DETAILS. 4. REFER TO DETAIL 1/S3.1 FOR CONSTRUCTION OF MULTIPLE STUD COLUMNS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARILY SHORING EXISTING FRAMING PRIOR TO REMOVING STRUCTURAL WALLS. 71 6 4'-0" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09/ I4/ 23 oll DESIGN: BTJ DRAWN: JEG CHECK: CMJ JOB NO: 22225.10 DATE: 04/ 1 8/23 RECEIVED Feb 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ld U LEI O Q LEI J w O CL z i 0) J Ora Q W z D I _ o U LaQ � z z p O W N < O O ul 0 LLI cn SHEET: S201 4= 1 ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131"0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = V-0" SIMPSON A35 (ONLY REQUIRED AT EXTERIOR HEADERS GREATER THAN 6' SPAN) (6) 0.131"0 x 3" NAILS TYPICAL STUDS NAILING PER TYP BUILT-UP STUD COLUMN DETAIL AT HOLDOWNS: PROVIDE FULL HT HOLDOWN CHORDS PER HD SCHED. OTHERWISE: (1) 2x FULL HT TYPICAL HEADER DETAIL SCALE: 1" = V-0" TYP DOUBLE TOP PLATE BEAM OR HEADER PER PLAN AND NOTES CRIPPLE STUDS PER PLAN AND COLUMN SCHEDULE OR STRUCTURAL NOTES NOTE: SUPPORTS AT SOLID POSTS SIM BEAM PE AND SCF SIMPSON LTP4 i FRAMING Al EACH SIDE OF SOLID OR ML STUD COLUMN PE1. 1 u-m BEAM WIDTH, MIN UNO PARALLEL TO STUD WALL JOIST DIRE( PER PLAN STUD WALL TYPICAL FLUSH BEAM SUPPORT DETAILS SCALE: 1" = V-0" M COLUIVIIV 1 - 1 ­1 PERPENDICULAR TO STUD WALL STUD WALL EXIST SECTION SCALE: 1" = V-0" EXIST JOISTS EXIST BEAM SIMPSON HU FACE MOUNT HANGER ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 09/ 123 1 J F- FC- z C 0 m � N z o U � N W w w 0 d M M W Q.1:*-I C) Ql 1010 Y Q DESIGN: BTJ DRAWN: JEG CHECK: CMJ JOB NO: 22225.10 DATE: 04/ 1 8/23 RECEIVED Feb 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W U () W J 0 Q 0 O F_ Ld N W O 0 z � 00 0) J Ora Q mZ�:: 10:� ZD I _ o U LaQ � z z � o � o N :2 Q O O 0 T­ w cn SHEET: S3ml