Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2024-0050_Fire_Alarm_Equipment_Specification_Sheets_7.1.2024_1.08.29_PM_4352617
. • • • Powered by Experience. Driven by Excellence:' A New Fire Alarm Communicator for: Caliber Collision #2923 23510 Highway 99 Edmonds, WA 98026 System/Installation Narrative: Install a new Napco Starlink SLE-MAX2-CFBPS Cell Dialer to monitor the existing fire alarm panel. The system design is by Jody Congleton, SET, NICET level IV, Applications Engineer, Staff Designer for ADT Commercial. Email: jongleton(&,,everonsolutions.com. Ph. direct line: 251-583-7165 );, The System will consist of o Napco Starlink SLE-MAX2-CFBPS Cell Dialer. ➢ The 120vac circuit for the Cell Dialer must be dedicated. The circuit must be identified at the control panel as well as the electrical panel. The disconnect means must be labeled, painted red and mechanically locked to prevent accidental disconnect. ➢ The cell unit will report to a U.L. Listed Monitoring Center for Remote System Type monitoring. U.L. Certificate enclosed. ➢ Off Premise notification shall be accomplished by Cellular Sole Path communication method. ➢ The NAPCO Starlink cell unit will have backup power source of one 12vdc, lamp battery for 12vdc operation, capable of meeting/exceeding the 24hr standby period followed by 5 minutes of alarm at maximum system load. ➢ Copies of Fire Marshal approved, stamped, signed drawings along with a complete user's manual will be left with the Site Manager for their reference and all future annual inspections. Site personnel will be provided training on proper use of the NAPCO Starlink by the installation contractor. ➢ An NFPA Record of Completion will be submitted. As -Built (Record) drawings will be generated upon completion of a successful final inspection and copies will be provided to the customer and kept on file with ADT Commercial. Party Site No.: 567560 UL Expires: 31-Dec-2024 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm / Service Company identified below is included by - UL Solutions (UL) in its UL Product iQ directories as eligible to use the UL Listing Mark in connection with Certificated Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the System and the Certificate is active under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property. Listed Service From: IRVING , TEXAS Alarm / Service Company: (567560) ADT COMMERCIAL 4221 W JOHN CARPENTER FWY IRVING , Texas 75063-2924 UNITED STATES The Alarm / Service Company is Listed in the following Certificate Service Categories: File Vol No. CCN BP10566 1 CRZM S2684 20 UUFX BP1790 3 CPVX 1 Listing Category Monitoring Stations, National Industrial Security Central -station Protective Signaling Services Central -station Burglar Alarm Systems ***THIS CERTIFICATE EXPIRES ON 31-DEC-24*** "LOOK FOR THE UL ALARM / SYSTEM CERTIFICATE" /—N I C ET\° NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES° Providing Certification Programs Since 1961 BE IT KNOWN THAT Jody Congleton IS HEREBY AWARDED THE FOLLOWING CERTIFICATION Fire Alarm Systems Level IV Certification Number 108686 aillme Valid Through 2027-06-01 1 nicet.org/verify BASED UPON SUCCESSFUL DEMONSTRATION OF REQUISITE KNOWLEDGE, EXPERIENCE AND WORK PERFORMANCE AS SET FORTH BY THIS INSTITUTE. s, CHAIR OF THE NICET BOARD OF GOVERNORS A DIVISION OF THE NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS Sta rLi n k Fi re MAX 2: SLE-MAX2-Series The Power of 2: Dual SIM, Dual Path by Napco • Dual SIM, Dual Path Universal full data 5G LTE-M cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere nationwide • One Model to Stock: Provides both Verizon4 &AT&T* Cell Networks plus either sole or dual path cell/IP reporting (selectable by plan) • Auto -Network -Select by Site - Upon power up, the signal -strength provided by each cell carrier is analyzed at the site, and the unit will lock -in the best carrier automatically, ie.,AT&T orVerizon.Thereafter, it's periodically reviewed and dynamically swapped when needed. • EZ Cell -Network ID- Red or Blue Indicators - Inside the unit, the Carrier Indicators will light Blue for AT&Tor Red forVerizon connection (also test button indicates signal strength on each for manual check) • See /Set SIM Status Remotely - using a PC or smart device, the StarLink Network Operations Center(NOC), in Napco Headquarters, NY, can be accessed allowing you used to set parameters or view current status, Dual SIM status of accounts • Supports 12V-24V FACUs, No Panel Reprogramming with those that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup. • UL & NFPA Code -compliant, replaces 2 POTs lines per FACU saves thousands of dollars per year overthe leased landlines. (Show accounts savings -Free SalesTool /CalculatorApp left) • Proven StarLink Reliability & Best 5G LTE-M Performance - Works where others can't - Signal Boost" Circuitry & unique dual -diversity twin antennas, maximizing signal acquisition and eliminating the multiphase -effect signal-clash/drop-outs single -antenna units are prone to. • Easiest installation, powered by panel, NO extra power supply, NO extra conduit. (Excludes Metal Direct AC -Powered Model, shown below.) • Labor -Saving Supervision Features Save Time & Money- Uniquely including 4 supervised, programmable EOLR zone inputs; 2 Form C Relay outputs (no extra supervision modules to buy or install); plus, 2 Telephone style jacks for easy FACU-connection. Self -supervised on 4 wires. • Easy -Repeat Account Templates - Save your typical account setup and reuse for goof -proof communicator programming & fast deployment. • Free StarLink FACU-Saver App - Smartphone Pro sales tool for calculating/demonstrating account's cellular cost -savings with dealer by number of lines & locations vs. copper POTS lines leased from phone co. FREE download on Apple Store or Google Play. • Pro Incentive Instant Rebate Program - Dealers save on new and retrofit installations, replacing POTS, old radios, sunset networks and even new installations. ot;Pto°,okay (Nothing to mail in/fill out; Service credit automatically applied upon valid plan activation. See details online; scan QR code on back) • UL& NFPA 72 Fire Code -Compliant, the Starl-ink Max2 Fire Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal supportfor any brand 12Vto' `v` 24Vfire alarm control panel (FACU), reporting in Contact ID and 4/2.With broadest nationwide coverage footprint, Verizon or AT&T, using proven StarLink circuitry, they are also available in locking metal models. ' r � � r • Over -the -Air Upgradeable Firmware Path Cell or Cell/IP; for updates without a truck -roll. One Dual SIM Dual Path Model is Both Verizon and AT&Tand Sole or Dual Path with Cellular + Internet Option. StarLink Fire provides full data reporting, in sole & dual path, as a primary or backup, to any central station of your choice, w/o requiring any special equipment on premises.The units are very easily activated, plans for dual or sole path & check -in periods are selected, and 24/7 account management is provided all through www.napcocomnet.com. Easy, Universal Installation at Every Application; standardly w/ Panel- Powered Technology" or metal units with choice of power source. Starl-ink Fire Communicators are easily connected to any 12Vto 24V panel or Fire Alarm Control Panel (FACU) using easy Quick -Connect FACP modular jacks. For any application, StarLink Max Fire 2 Series comes in standard,ABS plastic Panel -Powered Technology'" (powered by the panel), models, or in metal housings w/ or w/o & choice of power options, i.e., direct -connect 120VAC or Plug-in transformer. Quick Tip: Using Stadink Fire Max2 with Power Supply models (suffix -PS) eliminates the need to do recalculations on the fire system being retrofitted as well. StarLink Fire is End -to -End UL 864 Listed to protect signal reliability, speed & performance for critical life and safety alarm reports for maximum life safety & liability protection. UL-Listed from the UL 864 StarLink Fire Max 2 communicator, to Napco's NY UL 864 Network Operations Center (shown below in map), to any Central Station's UL Listed Receiver. (It is also backed by Disaster Recovery NOC in PA for immediate, mirrored emergency switchover.' STARLINK: ALL SIGNALS, ALWAYS IN THE USA SPECIFICATIONS: (Apply to all models unless otherwise stated) SLE-MAX2-FIRE & SLE-MAX20111: Electrical Ratings for +12V / 24V (Models w/o Power Supply) • InputVoltage:10-24VDC regulated (power -limited output from UL Certified FACUIpanelAux/Remote Fire Power). • Input Current: 24VDC standby: 85mA SLE-MAX2-CFBPS: Electrical Ratings for 120VAC, 60Hz (Models with Power Supply) • InputVoltage:120VAC nominal • Input Current: 200mA maximum • Maximum Charging Current: 200mA Electrical Ratings Fire Input 1: • InputVoltage: 9-25VDC • Max Input Current: Up to 2mAfrom FACU NAC circuit Electrical Ratings for Inputs 2 to 5 (Class B): • Maximum Loop Voltage: 25VDC • Maximum Loop Current:1.2mA(metal models);1.7mA(plastic) • End of Line Resistor (EOLR) Value: 10K Electrical Ratings for PGM3 Output: • Open Collector Output: Max Voltage 3V when active; 25V max. when not. • PGM Max Sink Current: 50mA (up to 15VDC), 25mA (15.1VDC -25VDC) Physical & Environmental • Plastic Housing: 8 x 51/2 x 11/2 "(WHD) + antennas (tea, supplied) 81/4" F • Metal Housing:111/2 x 91/2 x 31/2"(WHD) + antennas (tea, supplied) 81/4" • Housings: 2 Keyholes for wall mount • Operating Temp.32 to 1207, 93%Humidity Max. COMPLIANCES: NFPA 72 Eds: 2022, 2019, 2016, 2013, 2010; UL 2610, UL 985, UL1023, UL864 NYC FD, LAFD Napco US Network Operations Center (NOC) UL 86410th Ed.,UL 1 StarLlnk 2 SLE-MAX2 SERIES Fire Dual SIM/Dual Path FIRE MRH� Z Commercial Fire Alarm Cell Communicators • Dual SIM models auto -select optimal cell carrier - and Red or Blue LED Indicators inside signal Verizon orAT&T respectively, shown right. • LED Status /Trouble Indicators 3 Radio Status LED Indicators (visible from outside standard model housing) - Green, Signal Strength; Amber- Busy/Activation; Red -Trouble. (Additional internal LEDs, not visible with cover closed, i.e., for troubleshooting and forAT&T orVerizon network selection, status). Power LED indicator viewable on outer metal enclosure models. • Sole or Dual Path 5G LTE-M Cell Commercial Fire Alarm Communicator in One -Simply select Cell or Cell/IP Service Plan & check -in period: 5 minutes, 60 minutes, 6 hours or 24 hours. • Signal Boost and Patented Switching Dual Diversity Antenna for maximum signal acquisition & null /signal -clash avoidance, receiving signals on both antennas (2 supplied, nothing extra to buy.) • "Return Receipt" Fully -Supervised Communication Path between premise & central station, keeping channel open until kiss -off is received from Central Station receiver •' •' LVA• Dual Low Current Current r r Description SIM/ Verizo t Draw, Draw, Dual II/IP Peak Path (@24V) Universal Fire SLE Communicator, Dual SIM, Dual Path, Panel- 85mA 325mA FIRE FIRE Powered Technology, ABS Plastic Housing Universal Fire SLE-MAX2- Communicator, Dual SIM, Dual 85mA 325mA CFB Path, Panel -Powered Technology Universal Fire H Communicator, Dual SIM, Dual Path, Direct SLE-MAX2- AC Power 120VAC Metal Housing w/ 200rnA 200mA CFBPS Provision. For Plug-in t✓ TRF12 XFormer,16VAC, 10th Ed., CSFM, 20VA (w/ provision for backup battery) 10, UL 1635 OPTIONS/ACCESSORIES: SLE-WIFI-MODULE: Optionally connects supported dual path models to Internet via WiFi, eliminating Ethernet cable connection. Requires 7AH battery. (see WI2191) SLE-ANTEXT30: StarLink Omni-X Optional Extended Range Marine -Grade Complete Antenna Kit, w/ 30' of ultra low -noise LMR 300 cable, all hardware & ground fault isolator plate. SLE-ANTEXT50: as above, 50' cable t SLE-ANTEXT75: as above, 75' cable t SLE-ANTEXT100: as above, 100' cable SLE-ANTEXT04: as above, 4' cable [Also E-FIRE-VR: FACU Voltage Drop Kit, maintains safe input voltage < 27.5VDC F12: Plug in AC Transformer, used w/SLE MAX2 CFBPS mode1,16.5V/ 20VA e subject to local code). M TAMPERKIT: Tamper switches and screws to protect metal housing where required. - E-ULPS-R: Power Supply, for installations where FACU cannot provide Aux Power. E-FMBB: Opt.Metal Cable Management Backbox for surface mounting plastic Starlink mmunicator models adjacentto FACUs on same plane. Radio easily snaps in on 4 stand offs, rewiring. Red metal enclosure wl3/a" cable knockouts; 2 Connectors & 4"Conduit, supplied. See Firelink FACUs with built-in Starlink Communicators & LCD Touchpads Door, addressable & conventional, cloud -programmable. Addressable, Conventional Fire Alarm Systems & o • o Leading Commercial Fire Cellular Communications _ For Compliance, Always Consult with AHJ &Tech Docs by Model, i.e., SLE-MAX2-FIRE(Plastic)W12609LF; SLE-MAX2-CFBPS,-CFB(Dua I Path Metal) ❑r•� W12642LF.Starlink&Starl-inkMAXFire are trademarks ofNAPCOSecurity Tech nclog ies,Inc. Other marks remain intellectual property of their FOR MORE respective companies. Preliminary data& promotions subject to change without notice.©NAPCO2024.1 A852 Yuasa Technical Data Sheet Yuasa NP7-12 Industrial VRLA Battery Specifications Nominal voltage (V) 12 10-hr rate Capacity to 1.8V/Cell at 20°C (Ah) 6.4 20-hr rate Capacity to 1.75V/Cell at 20°C (Ah) 7 Dimensions Length (mm) 151 (+1) Width (mm) 65 (+1) Height over terminals (mm) 97.5 (+2) Mass (kg) 2.2 Terminal Type FASTON - Quickfit / release UST where stated) 4.75 Operating Temperature Range Storage (in fully charged condition) -200C to +60°C Charge -15°C to +50°C Discharge -20°C to +60°C Storage Capacity loss per month at 20oC (% approx.) 3 Case Material Standard ABS (UL94:HB) FR version available UL94:V0 Charge Voltage Float charge voltage at 200C (V)/Block 13.65 (+1 %) Float charge voltage at 20°C (V)/Cell 2.275 (+l %) Float Chg voltage tmp correction factor from std -3 20oC (mV) Cyclic (or Boost) charge Voltage at 20°C (V)/Block 14.5 (+3%) Cyclic (or Boost) charge Voltage at 20°C (V)/Cell 2.42 (+3%) Cyclic Chg voltage tmp correction factor from std -4 20oC (mV) NP7.1 valverd bl & I I nw ead ai YUASA pb 0 o:a Wwwyqu saeuraie•cQT Layout 0 Charge Current 3rd Party Certifications Float charge current limit (A) No limit ISO9001 - Quality Management Systems Cyclic (or Boost) charge current limit (A) 1.75 Mao �� Maximum Discharge Current 901me a�a ,ge U 1 second (A) 210 Ce 0 11-IFM7 6 1 minute (A) 48 Impedance Safety Measured at 1 kHz (mid) 23 Design Life & Approvals EUROBAT Classification: Standard Commercial 3 to 5 years Yuasa design life at 20°C (yrs) up to 5 Data Sheet generated on 02/05/2024 - E&OE Installation Can be installed and operated in any orientation except permanently inverted. Handles Batteries must not be suspended by their handles (where fitted). Vent valves Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal. Gas release VRLA batteries release hydrogen gas which can form explosive mixtures in the air. Do not place inside a sealed container. Recycling YUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations.