Loading...
APPROVED BLD-RESUB 4-Structural_Analysis_or_CalculationsREVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT RESUB Jul 30 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Ramm Remodel Project Number: 20-167 5073rdAve S Edmonds, WA 98020 Structural Calculations Calculations................................................S1 — S7 � �46 36 S�ONAL �� 5/14/21 Prepared by: Nabil Kausal-Hayes, PE 206-601-9728 www.nkhengineering.com May 14th, 2021 NKH ENGINEERING Background PROJECT: Ramm Remodel DESIGNER: NKH DATE: May 14th, 2021 JOB #: 20-167 PROJECT SUMMARY & DESIGN CRITERIA Project Summary: This is a remodel on an existing single story, wood framed house with a basement for the Ramm family in Edmonds, WA. The structure consists of wood roof, ceiling, & floor joists bearing on wood framed walls, posts, & beams. The house is supported by existing concrete retaining walls & shallow spread footings. This project is designed in accordance with the 2015 International Building Code along with the codes listed below and corresponding state & city/county amendments. Notes: All input variables are highlighted in yellow, resources bolded, and links to resources bolded and underlined. Areas highlighted in blue are code/design checks and green - unity checks. Resources: -American Wood Council (AWC). (2018). "National Design Specifications for Wood Construction (NDS)." -American Wood Council (AWC). (2015). "Special Design Provisions for Wind and Seismic (SDWS)." -American Concrete Institute (ACI). (2014). "Building Code Requirements for Structural Concrete (ACI 318-14)." -American Institute of Steel Construction (AISC). (2016). "Steel Construction Manual." 15th Ed. -American Society of Civil Engineers (ASCE). (2016). "Minimum Design Loads for Buildings and Other Structures." -StateofWashington (2018)."International Building Code (IBC)." -Applied Technology Council (ATC). (2018). "Hazards by Location" https:#hazards.atcouncil.org Material Properties -Soil Bearing Pressure (min per IBC1806.2) -Frost Depth -Active & Passive Soil Pressure Concrete: -Compressive Strength -Density, Normal Weight -Density, Light Weight -Reinforcing Steel, ASTM A615 Steel: - Modulus of Elasticity -Anchor Rods/Bolts, ASTM A307 Shear & Tension Yield Strength Wood: -Solid Sawn Joists, Beams, Headers, & Studs -Glulam Beams pbrg:= 1500psf FD:= 12in qa := 35• pcf qp := 250• pcf fc:= 2500psi _Yconc:= 150pcf 1conc LW 115pcf r:= 60ksi E,.= 29000ksi = 24ksi . _ 45ksi AWN DF-L #1 6x & Larger, DF-L#2 All Other (UNO) 24F-V4 (Simple Span), 24F-V8 (Cont/Cantilever) 01_Summary _Design Criteria.xmcd NKH Engineering S1 Gravity Loading o v Roof/Ceiling Dead Load Roofing Insulation Ceiling Sheathing t:= 0.5in Structural Members Mechanical Misc. R:= 1.5•psf I:= 1.5•psf L.= 1.5•psf SH:=(.t ).0.4•psf = 1.6•psf 125in nXn = 2.5• psf M:= 1•psf MISC:= 0.4•psf DLrf:= R+I+C+ SH+ S+M+MISC Wall Dead Loads Exterior Wood Interior Wood Live Loads Roof Floor Live Load Deflection Criteria L L Arf TL : = 2Arf LL 60 : = 3 pext w 1Opsf pint 9psf LLrf:= 20•psf LL flr : = 40psf L L Aflr_TL:= 360 Aflr_LL'= 480 DLr f = 10• psf Roof Snow Load DLpV:= Opsf SL:= 25psf 01_Summary _Design Criteria.xmcd NKH Engineering S2 F O R T E' • B20-167 SUMMamm ARY model REPORT Roof Framing Member Name Results Current Solution Comments Kitchen/Living Beam Passed 1 piece(s) 5 1/2" x 10 1/2" 24F-V4 DF Glulam Closet Beam Passed 1 piece(s) 4 x 4 DF No.2 Sistered Joists Passed 1 piece(s) 2 x 6 DF No.2 @ 24" OC Free Standing Post Passed 1 piece(s) 4 x 6 DF No.2 ForteWEB Software Operator Job Notes Nabil Kausal-Hayes NKH Engineering (206) 601-9728 NKH Eng nabil@nkhengineering.com nAng Weyerhaeuser 5/14/2021 6:44:10 PM UTC ForteWEB v3.2 File Name: 20-167 Ram$lmodel Page 1 / 5 aFORTE'CM Roof Framing, Kitchen/Living Beam 1 piece(s) 5 1/2" x 10 1/2" 24F-V4 DF Glulam PASSED All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 3907 @ 2" 12513 (3.50") Passed (31%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 3442 @ 1' 2" 11733 Passed (29%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 18483 @ 9' 9 1/2" 23244 Passed (80%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.890 @ 9' 9 1/2" 0.962 Passed (L/260) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 1.291 @ 9' 9 1/2" 1.283 Passed (L/179) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 19' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Column - DF 3.50" 3.50" 1.50" 1215 2693 3908 Blocking 2 - Column - DF 3.50" 3.50" 1.50" 1215 2693 3908 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 7" o/c Bottom Edge (Lu) 19' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 19' 7" N/A 14.0 1 - Uniform (PSF) 0 to 19' 7" (Front) 11' 10.0 25.0 Default Load System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Nabil Kausal-Hayes NKH En§ NKH Engineering (206) 601-9728 nabil@nkhengineering.com lil@ 5/14/2021 6:44�M UTC Ing ForteWEB 0.2, Engine: V8.2.0.17, Data: 1.0.16 Weyerhaeuser File Name: 20-167 Ramm Remodel Paget/5 aFORTE'CM Roof Framing, Closet Beam 1 piece(s) 4 x 4 DF No.2 PASSED I All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 649 @ 2" 7656 (3.50") Passed (8%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 484 @ 7" 1691 Passed (29%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 639 @ 2' 3 1/2" 924 Passed (69%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.073 @ 2' 3 1/2" 0.213 Passed (L/695) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.104 @ 2' 3 1/2" 0.283 Passed (L/491) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDs. • This product has a square cross section. The analysis engine has checked both edge and plank orientations to allow for either installation. Supports Bearing Length Loads to Supports (Ibs) Accessories Available Required Dead Snow Total 1 - Trimmer - DF 3.50" 3.50" 1.50" 190 458 648 None 2 - Trimmer - DF 3.50" 3.50" 1.50" 190 458 648 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 4' 7" o/c Bottom Edge (Lu) 4' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads ' Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 4' 7" N/A 3.1 1 - Uniform (PSF) 0 to 4' 7" (Front) 8' 10.0 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Nabil Kausal-Hayes NKH En§ NKH Engineering (206) 601-9728 nabil@nkhengineering.com 5/14/2021 6:44 M LTC lil@ InCj ForteWEB 0.2, Engine: V8.2.0.17, Data 1.0.16 Weyerhaeuser File Name: 20-167 Ramm Remodel Page 3/5 aFORTE'CM Roof Framing, Sistered Joists 1 piece(s) 2 x 6 DF No.2 @ 24" OC PASSED p All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 230 @ 2 1/2" 3281 (3.50") Passed (7%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 178 @ 9" 1139 Passed (16%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 333 @ T 3 1/2" 883 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.049 @ 3' 3 1/2" 0.308 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.068 @ 3' 3 1/2" 0.411 Passed (L/999+) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • A 15% increase in the moment capacity has been added to account for repetitive member usage. • A 9.4% decrease in the moment capacity has been added to account for lateral stability. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Available Required Dead Snow Total 1 - Stud wall - DF 3.50" 3.50" 1.50" 66 165 231 Blocking 2 - Stud wall - DF 3.50" 3.50" 1.50" 66 165 231 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) End Bearing Points Bottom Edge (Lu) End Bearing Points Vertical Load Location (Side) Spacing Dead (0.90) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 6' 7" 24" 10.0 25.0 Default Load System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Nabil Kausal-Hayes NKH En§ NKH Engineering (206) 601-9728 nabil@nkhengineering.com 5/14/2021 6:44;,1�,VM UTC lil@ InCj ForteWEB 0.2, Engine: V8.2.0.17, Data 1.0.16 Weyerhaeuser File Name: 20-167 Ramm Remodel Page 4 / 5 aFORTE'CM Roof Framing, Free Standing Post 1 piece(s) 4 x 6 DF No.2 PASSED Post Height: 8' Design Results Actual Allowed Result LDF Load: Combination Slenderness 27 50 Passed (55%) Compression (Ibs) 3908 11074 Passed (35%) 1.15 1.0 D + 1.0 S Base Bearing (Ibs) 3908 12031 Passed (32%) -- 1.0 D + 1.0 S Bending/Compression 0.35 1 Passed (35%) 1.15 1.0 D + 1.0 S • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on Nos. Supports Type Material Member Type : Free Standing Post Base I Beam Douglas Fir Larch Building Code : IBC 2018 Design Methodology : Aso Max Unbraced Length Comments Full Member Length I No bracing assumed. Drawing is Conceptual Dead Snow Vertical Load (0.90) (1.15) Comments 1 -Point (lb) 1215 2693 Linked from: Kitchen/Living Beam, Support 1 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Nabil Kausal-Hayes NKH En§ NKH Engineering (206) 601-9728 nabil@nkhengineering.com 5/14/2021 6:44:�,0 PM UTC In@ ing ForteWEB 0.2, Engine: V8.2.0.17, Data11§788.1.0.16 Weyerhaeuser File Name: 20-167 Ramm Remodel Page 5 / 5 NKH Engineering Project Title: Ramm Remodel Engineer: NKH Project ID: 20-167 Project Descr: Printed: 14 MAY 2021, 11:41AM File: Slab Check Point Load on Slabc6 I Software copyright ENERCALC, INC. 1983-2020, BuiId:12.2012.20.8.17 KW-06013860 NKH Engineering DESCRIPTION: Slab Check Code References Calculations per IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-10 Analytical Values d - Slab Thickness 4.0 in FS - Req'd Factor of Safety 3.0 :1 Analysis Formulas Pn = 1.72 [ (Ks R1 / Ec) 10,000 + 3.6] Fr d A 2 Ks = Soil modulus of subgrade reaction R1 = 50% plate average dimension = sgrt( PIWid ' PILen) /2 Ec = Concrete elastic modulus Fr - Concrete modulus of rupture = 7.5 " sgrt( f'c ) d - Slab Thickness Ks - Soil Modulus of Subgrade Reaction 100.0 pci Ec - Concrete Elastic Modulus 3,122.0 ksi fc - Concrete Compressive Strength 3.0 ksi µ - Poisson's Ratio 0.150 Min. Adjacent Load Distance 30.473 in Min Adjacent Column Distance = 1.5 * ([ Ec d A 3 / (12 * ( 1- u^2 ) Ks ] A 1/4 ) Ec = Concrete elastic modulus d - Slab Thickness u - Poisson's ratio Ks = Soil modulus of subgrade reaction Load & Capacity Table Plate (in) R1 Applied Concentrated Load on Plate - (kip) Load ID Wid Len (in) D Lr L S W E Post 3.50 3.50 1.75 1.22 2.69 +D+S Governing Ld Comb Pu (kip) 3.9 Pn (kip) Check 47.0 Pass, FS=12.04 - 3 NKH Engineering S8