Loading...
APPROVED BLD ENG PLN RESUB 2-BLD2023-1007+Plan_Set+10.25.2023_9.02.19_AM+3859859ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE !�r APPROVED PLANS MUST BE Location Branding Document WA060 City/State: Address: Initial Date: Revision Dates: ON JOB SITE Edmonds, WA 21401 72nd Ave W 3-23-2023 3-28-2023 3-29-2023 8-22-2023 9-14-2023 9-28-2023 City Of Edmonds Building Department -------------------------- Work 3 SIGNS ----------------------------- ---- ---------------------------------------------- Address 21401 72ND AVE W ------------------ ------------------ Owner OPTUM --------------------------------- Approved Date 10 30 2023 Building Official Eric, CartX APPROVED BY PLANNING Oct 25 2023 RES U B Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Permit Number BLD2023-1007 PPRIORITY Sign Existing Sign Action Proposed Sign Qty. Sign Key: Action Key: FFE01 Illum. Push Thru Letterset IFRR] Illum. Push Thru Letterset 1 I -Interior RR -Remove &Replace E - Exterior NI -New Install NA No Action RE Remove Existing E03 Cabinet Sign RR RCW Illum. Letterset 1 LLC - Landlord Controlled E04 Cabinet Sign RR RCW Illum. Letterset 1 ENGINEERING DIVISION APPROVED AS NOTED 10/27/2023 Note: All equipment and staging shall occur on private property. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. fT.. E01 tA� OPTUM OWNER/CONTRACTOR IS RESPONSIBLE FOR 21401 72ND AVE W EROSION CONTROL AND DRAINAGE EDMONDS WA 98026 ZONE:CG PARCEL# 00580700002208 T n n . ` • D lK�llill�leJ.1�` •� a o o D o ice.. r E J E03100 � �� •� � �' � o' , 1�, ♦ 0 T • e r ' 40 RESUB N �v+ � � �'��► � Oct 25 2023 ' CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Drawing # Address: 2140172nd Ave W OE 160545 City/ST: Edmonds, WA Date: 3-23-2023 Designer: AD PM: WH n File Location: STND Drive/clients/ CSTM _ Revisions: V Underwriters ®� Laboratories, Inc. All dimensions are imperial metric. I S X X X X x x areunless n are scaled as noted when led as scaled PPRIORITY ❑ AS Q CR O EN x x Sign components to be in printed on an 11x17 sheet. x x strict UL compliance. s.• Z.- CG C—,_RFlagJ[ Setbacks: Requiretl Actual (1Wex. Sidss y_ ex. Rear P_X_ omen Height 75' ex. �.1'• + r - ir ••� C�1, ,�,be o COMPLIANCE WITH ECDC 20.60.030.A MWEST ELEVATION LENGTH: 188' PROPOSED SIGN (E01) 4.27 SQ FT ~ EAST ELEVATION LENGHT : 188' d PROPOSED SIGN (E04) 33.5 SQ FT SOUTH ELEVATION LENGHT: 145' k PROPOSED SIGN (E03) 44 SQ FT W*4 �'� -• . y� SIGN E04 IL AL AL �► __ .. ! r SIGN E03 � � _ ; i S Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT E01j Custom Face Replacement (Oty.1) Remove existing faces. Install new .125" thick white aluminum faces routed with 3/4" push-thu acrylic. Screw mounted around perimeter to fascia. Paint exterior cabinet as shown. Note: All equipment and staging shall occur on private property. COLOR/MATERIAL SPECIFICATIONS ❑ Face: Painted MP N202SP White, Satin Finsish Cabinet: Painted MP00573, Satin Finish Logo: 1" Clear acrylic push-thru (3/4" exposed) with aluminum overlay painted MP08528 ❑ LEDs: Sloan Prism White 4000K 24V #701269-4W24SJ1-MB Power Supply: Sloan #701895-24C1 �~ �~ OC-RF-O-3 optum x' BEFORE AFTER .125" routed aluminum face painted N202SP white; high reflective white interiors 3/4" push-thru clear acrylic with flame polished edges (1/2" exposed); 2nd surface #3735-50 White Diffuser film, first surface films as noted 16'-0" 3-10" um (,) Weld nut o 7, 0 t White LEDs scale 1 1:20 .125" flanged aluminum back; high reflective white interiors Drawing # OE 160545 Address: 21401 72nd Ave W City/ST: Edmonds, WA Date: 3-23-2023 Designer: AD PM: WH .125" routed aluminum face 3/4" push-thru clear acrylic (1/2" exposed) Weld nut RESUB Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT File Location: STND Drive/Clients/ CSTM x Revisions: Updated dimensions I AD 1 9.28.23 x x x V Underwriters ®� Laboratories, Inc. All dimensions are imperial metric. In x x areunless scaled are scaled as noted when led as PPRIORITY ❑ AS . CR O EN x x Sign components to be in printed on an 11x17 sheet. x x strict UL compliance. LE03JIlluminated Raceway Channel Letterset - South Elevation Remove existing letterset. Patch and paint fascia to like new condition. Install new illuminated raceway channel letterset as shown. Raceway painted to match fascia. Note: All equipment and staging shall occur on private property. Note: Entire elevation length is 145' COLOR/MATERIAL SPECIFICATIONS ❑ FACE: Plaskolite .118" Optix 2406LD Acrylic FILM: 3M #3630-3247 Translucent Orange (first surface) RETURNS:.063" Aluminum painted MP00573, satin finish (exterior surfaces); Interiors sprayed with Matthews Star-Brite white enhancement paint TRIM CAP: 1" Jewelite painted MP00573 to match returns ❑ LEDs: Sloan Prism White 4000K 24V #701269-4W24SJ 1-M B Power Supply: Sloan #701895-24C1 BACKS: 4mm White ACM (Alucobond or Alpolic) RACEWAY: paint to match fascia SW 7743, Mountain Road A B BEFORE 3.5" ■I C sf(BXC) OC-RCW-0-36 3'-0" 13'-3" 3'-10" 50.7 rounded to the nearest inch O P T U M Square Ft. Per Letter 12 11 5 6 10 SCALE 1 1:25 Drawing # OE 160545 Address: 21401 72nd Ave W City/ST: Edmonds, WA Date: 3-23-2023 Designer: AD PM: WH rounded to the nearest inch .063" aluminum letter return 1" trim cap bonded to letter face .118" translucent letter face LED module 4mm white ACM letter back anchor bolt 3.5"w x 5.5"h Narrow Body Raceway (add weep holes); paint to match fascia (typ) UL Listed weatherproof toggle disconnect Low voltage LED supply wiring 1/4" dia. weep hole with light baffle AFTER RES U B Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Revisions: File Location: STND X Updated to raceway I AD 1 3.28.23 X O Underwriters All dimensions are imperial Drive/Clients/ CSTM _ Updated dimensions per survey I AD 1 9.28.23 X Laboratories, Inc. unless specified metric. Items pR1�RITY x X are scaled as noted when ❑ As A CR O EN I x X I Sign components to be in I printed on an 11x17 sheet x X strict UL compliance. LE04JIlluminated Raceway Channel Letterset - Ease Elevation Remove existing letterset. Patch and paint fascia to like new condition. Install new illuminated raceway channel letterset as shown. Raceway painted to match fascia. Note: All equipment and staging shall occur on private property. Note: Entire elevation length is 188' COLOR/MATERIAL SPECIFICATIONS ❑ FACE: Plaskolite .118" Optix 2406LD Acrylic FILM: 3M #3630-3247 Translucent Orange (first surface) RETURNS:.063" Aluminum painted MP00573, satin finish (exterior surfaces); Interiors sprayed with Matthews Star-Brite white enhancement paint TRIM CAP: 1" Jewelite painted MP00573 to match returns LEDs: Sloan Prism White 4000K 24V #701269-4W24SJ 1-M B Power Supply: Sloan #701895-24C1 BACKS:4mm White ACM (Alucobond orAlpolic) RACEWAY: paint to match fascia SW 7743, Mountain Road SCALE 1 1:25 BEFORE A B C sf(BXC) OC-RCW-0-36 3'-0" 13'-3" 3'-10" 50.7 rounded to the nearest inch O P T U M Square Ft. Per Letter 9 8 4 5 7.5 Drawing # OE 160545 Address: 21401 72nd Ave W City/ST: Edmonds, WA Date: 3-23-2023 Designer: AD PM: WH rounded to the nearest inch .063" aluminum letter return 1" trim cap bonded to letter face .118" translucent letter face LED module 4mm white ACM letter back anchor bolt 3.5"w x 5.5"h Narrow Body Raceway (add weep holes); paint to match fascia (typ) UL Listed weatherproof toggle disconnect Low voltage LED supply wiring 1/4" dia. weep hole with light baffle AFTER RESUB Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT File Location: STND X Revisions: O Underwriters All dimensions are imperial Updated to raceway I AD 1 3.28.23 X Drive/clients/ CSTM Updated dimensions per survey I AD 1 9.28.23 X Laboratories, Inc. unless specified metric. Items x X are scaled as noted when PPRIORITY ❑ AS ❑ CR O EN X X Sign components to be in printed on an 11x17 sheet. X X strict UL compliance.