APPROVED BLD ENG PLN RESUB 2-BLD2023-1007+Plan_Set+10.25.2023_9.02.19_AM+3859859ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
!�r
APPROVED
PLANS MUST BE
Location Branding Document
WA060
City/State:
Address:
Initial Date:
Revision Dates:
ON JOB SITE
Edmonds, WA
21401 72nd Ave W
3-23-2023
3-28-2023
3-29-2023
8-22-2023
9-14-2023
9-28-2023
City Of Edmonds
Building Department
--------------------------
Work 3 SIGNS
----------------------------- ----
----------------------------------------------
Address 21401 72ND AVE W
------------------
------------------
Owner OPTUM
---------------------------------
Approved Date 10 30 2023
Building Official Eric, CartX
APPROVED BY PLANNING
Oct 25 2023
RES U B
Oct 25 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Permit Number BLD2023-1007 PPRIORITY
Sign Existing Sign Action Proposed Sign Qty.
Sign Key: Action Key:
FFE01 Illum. Push Thru Letterset IFRR] Illum. Push Thru Letterset 1 I -Interior RR -Remove &Replace
E - Exterior NI -New Install
NA No Action
RE Remove Existing
E03 Cabinet Sign RR RCW Illum. Letterset 1 LLC - Landlord Controlled
E04 Cabinet Sign RR RCW Illum. Letterset 1
ENGINEERING DIVISION
APPROVED AS NOTED
10/27/2023
Note: All equipment and staging shall occur on private property.
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
fT..
E01
tA�
OPTUM
OWNER/CONTRACTOR IS RESPONSIBLE FOR 21401 72ND AVE W
EROSION CONTROL AND DRAINAGE EDMONDS WA 98026
ZONE:CG
PARCEL# 00580700002208
T n n
. ` • D lK�llill�leJ.1�`
•� a o o D o
ice.. r E
J
E03100
� �� •� � �' �
o' , 1�, ♦ 0
T
• e
r ' 40 RESUB
N
�v+ � � �'��► � Oct 25 2023
' CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Drawing # Address: 2140172nd Ave W
OE 160545 City/ST: Edmonds, WA
Date: 3-23-2023
Designer: AD PM: WH
n
File Location: STND
Drive/clients/ CSTM _
Revisions:
V Underwriters
®� Laboratories, Inc.
All dimensions are imperial
metric. I S
X
X
X
X
x
x
areunless
n
are scaled as noted when
led as
scaled
PPRIORITY
❑ AS Q CR O EN
x
x
Sign components to be in
printed on an 11x17 sheet.
x
x
strict UL compliance.
s.•
Z.- CG C—,_RFlagJ[
Setbacks: Requiretl Actual
(1Wex.
Sidss y_ ex.
Rear P_X_
omen
Height 75' ex.
�.1'• + r -
ir ••� C�1, ,�,be o
COMPLIANCE WITH ECDC 20.60.030.A
MWEST ELEVATION LENGTH: 188'
PROPOSED SIGN (E01) 4.27 SQ FT
~ EAST ELEVATION LENGHT : 188'
d PROPOSED SIGN (E04) 33.5 SQ FT
SOUTH ELEVATION LENGHT: 145'
k PROPOSED SIGN (E03) 44 SQ FT
W*4
�'� -• .
y� SIGN E04
IL AL AL
�► __ .. ! r SIGN E03 � � _ ; i
S
Oct 25 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
E01j Custom Face Replacement (Oty.1)
Remove existing faces. Install new .125" thick white
aluminum faces routed with 3/4" push-thu acrylic. Screw
mounted around perimeter to fascia. Paint exterior
cabinet as shown.
Note: All equipment and staging shall occur on private property.
COLOR/MATERIAL SPECIFICATIONS
❑ Face: Painted MP N202SP White, Satin Finsish
Cabinet: Painted MP00573, Satin Finish
Logo: 1" Clear acrylic push-thru (3/4" exposed) with aluminum
overlay painted MP08528
❑ LEDs: Sloan Prism White 4000K 24V
#701269-4W24SJ1-MB
Power Supply: Sloan #701895-24C1
�~ �~
OC-RF-O-3 optum
x'
BEFORE
AFTER
.125" routed aluminum face
painted N202SP white;
high reflective white interiors
3/4" push-thru clear acrylic
with flame polished edges
(1/2" exposed); 2nd surface
#3735-50 White Diffuser film,
first surface films as noted
16'-0"
3-10"
um
(,) Weld nut
o
7, 0 t
White LEDs
scale 1 1:20 .125" flanged aluminum back;
high reflective white interiors
Drawing #
OE 160545
Address: 21401 72nd Ave W
City/ST: Edmonds, WA
Date: 3-23-2023
Designer: AD PM: WH
.125" routed
aluminum face
3/4" push-thru clear acrylic
(1/2" exposed)
Weld nut
RESUB
Oct 25 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
File Location: STND
Drive/Clients/ CSTM x
Revisions:
Updated dimensions I AD 1 9.28.23
x
x
x
V Underwriters
®� Laboratories, Inc.
All dimensions are imperial
metric. In
x
x
areunless
scaled
are scaled as noted when
led as PPRIORITY
❑ AS . CR O EN
x
x
Sign components to be in
printed on an 11x17 sheet.
x
x
strict UL compliance.
LE03JIlluminated Raceway Channel Letterset - South Elevation
Remove existing letterset. Patch and paint fascia to like
new condition. Install new illuminated raceway channel
letterset as shown. Raceway painted to match fascia.
Note: All equipment and staging shall occur on private property.
Note: Entire elevation length is 145'
COLOR/MATERIAL SPECIFICATIONS
❑ FACE: Plaskolite .118" Optix 2406LD Acrylic
FILM: 3M #3630-3247 Translucent Orange (first surface)
RETURNS:.063" Aluminum painted MP00573,
satin finish (exterior surfaces); Interiors sprayed with
Matthews Star-Brite white enhancement paint
TRIM CAP: 1" Jewelite painted MP00573 to match returns
❑ LEDs: Sloan Prism White 4000K 24V
#701269-4W24SJ 1-M B
Power Supply: Sloan #701895-24C1
BACKS: 4mm White ACM (Alucobond or Alpolic)
RACEWAY: paint to match fascia SW 7743, Mountain Road
A B
BEFORE
3.5"
■I
C sf(BXC)
OC-RCW-0-36 3'-0" 13'-3" 3'-10" 50.7
rounded to the nearest inch
O P T U M
Square Ft. Per Letter 12 11 5 6 10
SCALE 1 1:25
Drawing #
OE 160545
Address: 21401 72nd Ave W
City/ST: Edmonds, WA
Date: 3-23-2023
Designer: AD PM: WH
rounded to the nearest inch
.063" aluminum letter return
1" trim cap bonded
to letter face
.118" translucent
letter face
LED module
4mm white ACM
letter back
anchor bolt
3.5"w x 5.5"h Narrow Body Raceway
(add weep holes);
paint to match fascia (typ)
UL Listed weatherproof toggle disconnect
Low voltage LED supply wiring
1/4" dia. weep hole
with light baffle
AFTER
RES U B
Oct 25 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Revisions:
File Location: STND X Updated to raceway I AD 1 3.28.23 X O Underwriters All dimensions are imperial
Drive/Clients/ CSTM _ Updated dimensions per survey I AD 1 9.28.23 X Laboratories, Inc. unless specified metric. Items pR1�RITY
x X are scaled as noted when
❑ As A CR O EN I x X I Sign components to be in I printed on an 11x17 sheet
x X strict UL compliance.
LE04JIlluminated Raceway Channel Letterset - Ease Elevation
Remove existing letterset. Patch and paint fascia to like
new condition. Install new illuminated raceway channel
letterset as shown. Raceway painted to match fascia.
Note: All equipment and staging shall occur on private property.
Note: Entire elevation length is 188'
COLOR/MATERIAL SPECIFICATIONS
❑ FACE: Plaskolite .118" Optix 2406LD Acrylic
FILM: 3M #3630-3247 Translucent Orange (first surface)
RETURNS:.063" Aluminum painted MP00573,
satin finish (exterior surfaces); Interiors sprayed with
Matthews Star-Brite white enhancement paint
TRIM CAP: 1" Jewelite painted MP00573 to match returns
LEDs: Sloan Prism White 4000K 24V
#701269-4W24SJ 1-M B
Power Supply: Sloan #701895-24C1
BACKS:4mm White ACM (Alucobond orAlpolic)
RACEWAY: paint to match fascia SW 7743, Mountain Road
SCALE 1 1:25
BEFORE
A B C sf(BXC)
OC-RCW-0-36 3'-0" 13'-3" 3'-10" 50.7
rounded to the nearest inch
O P T U M
Square Ft. Per Letter 9 8 4 5 7.5
Drawing #
OE 160545
Address: 21401 72nd Ave W
City/ST: Edmonds, WA
Date: 3-23-2023
Designer: AD PM: WH
rounded to the nearest inch
.063" aluminum letter return
1" trim cap bonded
to letter face
.118" translucent
letter face
LED module
4mm white ACM
letter back
anchor bolt
3.5"w x 5.5"h Narrow Body Raceway
(add weep holes);
paint to match fascia (typ)
UL Listed weatherproof toggle disconnect
Low voltage LED supply wiring
1/4" dia. weep hole
with light baffle
AFTER
RESUB
Oct 25 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
File Location: STND X
Revisions:
O Underwriters
All dimensions are imperial
Updated to raceway I AD 1 3.28.23
X
Drive/clients/ CSTM
Updated dimensions per survey I AD 1 9.28.23
X
Laboratories, Inc.
unless specified metric. Items
x
X
are scaled as noted when
PPRIORITY
❑ AS ❑ CR O EN
X
X
Sign components to be in
printed on an 11x17 sheet.
X
X
strict UL compliance.