Loading...
APPROVED PLN ENG RESUB 7-Site_Plan+11.2.2022_3.20.55_PM+3199952o — — I A 110.3 EXISTING DECK I Q of Cn I I D 110.1 I 2-CA� ARAGE I I I I 1 2 OUFJIIDEKING I I I I I I I I CONSTIJCTION SITE Eff ANCE BACK YAR EXISTING RESIDENCE EXISTING FRONT ENTRY PORCH EXISTING GRAVEL FRONT YARD I -- 93.59' I� *SEE ATTACHED TESC DETAILS* HEMLOCK WAY I 00 --•--- B 117.7 PROPOSED NEW ADU ADDITION N 448 SQ. FT. FL. ELEV. 117.9 ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2014 SWMMWW BMP T.5.13 INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS AND ALL OTHER TEMPORARY STO KPILE I MEASURES THAT MAY BE REQUIRED DURING I C CONSTRUCTION. IF NEEDED TO BE COVERED 116.6 j \ WITHIN 24-HOURS 18'-0" � I I A 110.3 r--- ----- I I I EXISTING DECK I I I I I I I I I I I 0 -- I I Ll I 0 I I � I I I I r----+------- - D 110.1 %al TESL FILTER FENCE R / AROUND CONSTRUCTION 20' CONSTRUCTION SITE AREA PER CITY SITE ENTRA E DETAIL ER-900 NO STRUCTURES PERMITTED WITHIN 1 SEWER EASEMENT. NOTE: ADD FILTER SOCKS TO ANY CATCH BASINS DOWNSTREAM FROM CONSTRUCTION SITE STANDARD DETAIL ER-902 IND BACK YARD EXISTING RESI ENCE 2-CA� �ARAGE XISTING ASEMENT ATHR00 EXISTING FRONT —��� ----� ENTRY PORCH EXISTING G EILALK XI I / R! ITYR g I I / J TSIDE 93.59' HEMLOCK WAY W_ ADU 448 C 16.6 L LJ 0 I I NOTE ADU UTILITIES TO CONNECT TO EXISTING RESIDENCE. PLUMBING TO CONNECT TO EXISTING BATHROOM IN BASEMENT BOTH SEWER LINE AND WATER LINE. ELECTRICAL TO CONNECT TO MAIN EXISTING CIRCUIT BREAKER PANE IN EXISTING GARAGE. LOT COVERAGE LOT SIZE: 6098.4 SQ.FT. (.14 OF ACRE) EXISTING HOUSE, DECK, FRONT PORCH: 1622 SQ.FT. NEW ADU ADDITION: 448 SQ.FT. TOTAL BUILDING AREA: 2070 SQ.FT. LOT COVERAGE PERCENTAGE: 33% 20' SEWER EASEMENT AFN 1109442 EXISTING WATER METER ICO NOTE: THERE IS NO STORM WATER MANAGEMENT SYSTEM ON SITE SEWER MANHOLE COVER DATUM 118.2 HEIGHT CALCULATIONS: A= +110.3 B= +117.7 C= +116.6 D= +110.1 TOTAL=454.7 AVERAGE GRADE=113.6(454.7/4) • O U • J Q � QE5 z �V`tio CD N CD CD N CD (� Ll 0 m z � CD� o Ll w `f' C7 Co < m Q C nor w CD Ll N N l � N Ln J z zn CD m W Z W oCD o CD �o� o =D mo z�w Lw �U C J� cr_ d- 5 W m U U-) Applicant shall repair/replace all I I I—L� damage to utilities or frontage improvements in City right-of-way TESC SITE PLAN per city standards that is caused or occurs during the permitted project. SITE PLAN �J ^ I I v ENGINEERING DIVISION SCALE: 1"=10'-0" SCALE: 1"=10'-0" APPROVED AS NOTED 10 5 0 5 10 20 10 5 0 5 10 20 11/08/2022I 0 No No OWNER/CONTRACTOR IS RESPONSIBLE FOR O SCALE: 1 "=10'-O" EROSION CONTROL AND DRAINAGE SCALE: 1 "=10'-O" NO STORMWATER MANAGEMENT SYSTEM W REQUIRED AT THIS TIME. IF NEW AND/OR OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ADD GUTTERS/DOWNSPOUTS REPLACED IMPERVIOUS SURFACE EQUALS CD W ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. AND SPLASHIBLOCKS 2000SQFT OR GREATER, A STORMWATER CD N 0 O MANAGMEMENT SYSTEM MAY BE REQUIRED Ln W PER CITY CODES AND STANDARDS U Zone RS-6 Corner Flag CD APPROVED BY PLANNING C W Setbacks: Required Actual ( Ln Front 20' 24' Nov 09 2022 CD 0 5 101911Nothing N Sides in the permit approval process shall be DRAWING REVISED PER PLAN REVIEW COMMENTS RESUB 15' 1513" interpreted as allowing or permitting the maintenance BY NATALI E GRIGGS LETTER DATED 8-29-2022 . C Q � Rear of any currently existing illegal, nonconforming or Nov 03 2022 z unpermitted building, structure or site condition which Q Other is outside the scope of the permit application, regardless CITY OF EDMONDS W 25' 161211 of whether such building, structure or condition is DEVELOPMENT SERVICES LLJ Height shown on the site plan or drawing. Such building,U DEPARTMENT � structure or condition may be the subject of a separate enforcement action. BLD2022-0444 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL 0 I N a N NATIVE BACKFILL MATERIAL- 8„ I FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS -\ WIRE MESH FENCE TO SUPPORT FILTER FABRIC BURY BOTTOM OF FILTER MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CITY OF EDMONDS PUBLIC WORKS DEPARTMENT `St. 189\-' CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN FILTER FABRIC FENCE FILTRATION SYSTEMS APPROVED BY: R. ENGLISH REVISION DATE JANUARY 2018 STAN DARD D ETAI L ER-900 9• ad A .4 A 3 OVER FLOW HOLES (TYP) •• 4 •. a a ' e• •d• O• 2 ' 7 / CATCH BASIN FILTER SOCK WITH OVER FLOW HOLES (TYP) lki NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE—THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE CITY OF EDMONDS TEMPORARY JANUARY 2018 SEDIMENT TRAP � '7 PUBLIC WORKS FOR CATCH BASINS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH I E R - 9 0 2