APPROVED BLD2023-1408+Architectural_Plan+11.3.2023_4.39.59_PM+3881292U
z
U
0
0
Ln
Ln
a
0
V
GENERAL INFORMATION:
KAREN A. WHITE/GREG HEINZ
8226 187TH ST SW,
EDMONDS, WA 98026
KEVIN RICHARDS, ARCHITECT
RICHARTZ STUDIOS, INC
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
PHONE: 206 784 9652
kevin@richartzstudios.com
GENERAL CONTRACTOR:
OWNER
STRUCTURAL ENGINEER:
BRETT MOZDEN
SWENSON SAY FAGET
2124 3RD AVE, #100
SEATTLE, WA 98121
PHONE: 206 956 3763
CODE EDITIONS:
THIS PERMIT COMPLIES WITH THE FOLLOWING:
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2018 ICC PERFORMANCE CODE
2018 WASHINGTON STATE ENERGY CODE - RESIDENTIAL
2018 UNIFORM PLUMBING CODE
EDMONDS COMMUNITY DEVELOPMENT CODE TITLE 19
DRAWING LIST:
A0.0 COVER SHEET & GENERAL NOTES
A2.0 DEMO PLAN
A2.1 FLOOR PLAN
S2.0 STRUCTURE PLAN & CALCULATIONS
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
PROJECT INFORMATION:
PROJECT ADDRESS:
8226 187TH ST SW,
EDMONDS, WA 98026
PARCEL NUMBER:
00567500001800
LEGAL DESCRIPTION:
SEAVIEW FOREST TRACTS BLK 000 D-00 - LOT 18
PROJECT DESCRIPTION:
REMODEL MASTER BATHROOM AND FOYER.
0.31 ACRES
BUILDING AREA:
LIVING AREA: 2431 SF
ATTACHED GARAGE: 651 SF
PROJECT WORK AREA: ±100 SF
YEAR BUILT:
1956
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
APPROVED
CLANS MUST BE
ON JOF 0" E
PROPERTY ADDRESS
8226 187TH ST SW
185th St SW
00 co
W N
7
n n
> > Seaview Park Pic
`< and Tennis
186th St=SW- ,- -—186t6St SW 186th St SW 186W
�
A
co
0'
> <
187th St SW 18 th
co
co
188th St SW
co co
S Q
0 > .
<
Seaview
Elementary School
VICINITY MAP
N.T.S.
GOOGLE MAPS 2023
NORTH
Interconnected Smoke Alarms Are A Requirement �I
Of This Permit In Accordance With R314.2.2
.............................................
Separate Plumbing Permit Required.
Please apply via MyBuildingPermit.com
City Of Edmonds
Building Department
Work REMODEL
--------------------------------------------
Address 8226 187TH ST SW
Owner WHITE
----------------
-------------------------------------
Approved Date 11 /15/2023
Building Official Erg
---
Permit Number BLD2023-1408
REVISIONS
DATE - PAGES - CHANGES
REV1
REV2
REVS
REV4
REV5
GENERAL NOTES:
1 CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS
AND JOB CONDITIONS RELATED TO THIS WORK. ALL DIMENSIONS SHALL BE
CONSIDERED "NOMINAL" UNLESS NOTED OTHERWISE (U.N.0). DO NOT SCALE
DRAWINGS. USE WRITTEN DIMENSIONS ONLY. DIMENSIONS ON LARGE SCALE
DRAWINGS OR DETAILS WILL PREVAIL OVER SMALLER SCALED DRAWINGS.
WRITTEN DIMENSIONS ARE DRAWN TO THE FACE OF FRAMING, U.N.O. VERIFY
ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT, PROVIDE ALL BUCK OUTS,
BLOCKING, AND JACKS AS REQUIRED BY THE DRAWINGS AND OTHER TRADES.
ANY DISCREPANCY IN DIMENSIONS SHALL BE REPORTED IN WRITING TO THE
ARCHITECT FOR CLARIFICATION, OR APPROVAL OF MODIFICATION BEFORE
COMMENCING WORK. THE RESPONSIBILITY TO THE OWNER/ARCHITECT, SHALL
REST WITH THE CONTRACTOR OR ANY OTHER PERSON APPROVING SUCH A
CHANGE.
2 THE GENERAL CONTRACTOR, ALL SUB -CONTRACTORS AND ALL MAJOR
SUPPLIERS SHALL SUBMIT TO THE OWNER WITHIN 30 DAYS AFTER COMPLETION
ALL "RELEASE OF LIENS" FOR ALL WORK PERFORMED PRIOR TO FINAL PAYMENT.
PARTIAL LIEN WAIVERS SHALL BE SUBMITTED WITH MONTHLY DRAW REQUEST.
3 ALL WORK SHALL BE IN COMPLIANCE WITH THE INTERNATIONAL
RESIDENTIAL CODE, UNIFORM PLUMBING CODE, AND NATIONAL ELECTRIC
CODE AS ADOPTED AND MODIFIED BY THE LOCAL JURISDICTION AND ALL
OTHER LAWS, CODES, ORDINANCES AND REGULATIONS OF THE COUNTY, STATE,
AND FEDERAL JURISDICTIONS. (LATEST EDITION AND AMENDMENTS)
4 ALL MANUFACTURERS AND/OR SUPPLIERS SHALL SUBMIT SHOP
DRAWINGS AND/OR MATERIAL SAMPLES TO THE OWNER/ARCHITECT FOR
APPROVAL PRIOR TO FABRICATIONS.
5 ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE OR EXPOSED TO
WEATHER SHALL BE PRESSURE TREATED. WOOD SPECIFICATIONS TO CONFORM
TO 2018 IBC, OUTLINE SPECIFICATIONS, STRUCTURAL PLANS AND NOTES.
6 ALL OF THE GENERAL CONTRACTOR'S EQUIPMENT, SCAFFOLDING,
HOISTS, ETC, SHALL BE AVAILABLE TO THE OWNER/ARCHITECT AND THEIR
STAFF FOR INSPECTION OF ANY AND ALL WORK DURING NORMAL HOURS.
7 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DELIVERY POINTS,
HOISTS LOCATIONS, ACCESS TO AND FROM THE SITE OF THE BUILDING AND
UTILITY SERVICES.
8 ESTIMATE BID TO INCLUDE ALL NECESSARY AND REQUIRED PERMITS,
LICENSES, FEES AND INSURANCE- EVIDENCE OF WHICH MUST BE SUBMITTED
TO THE OWNER PRIOR TO CONSTRUCTION.
9 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
SUB -CONTRACTORS WORKING AT JOB SITE AND FOR ALL COORDINATION OF
WORK. THE MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTOR SHALL
FULLY COORDINATE ALL EQUIPMENT WITH OTHER TRADES. CONTRACTORS
SHALL BE RESPONSIBLE FOR FINAL HOOK-UP OF ALL EQUIPMENT NOT
FURNISHED BY THEM BUT REQUIRED FOR FINAL COMPLETION.
10 GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF ALL
MATERIALS AT JOB SITE UNTIL FINAL ACCEPTANCE OF WORK BY OWNER.
11 ANY SUB -CONTRACTOR CUTTING INTO WORK ALREADY COMPLETED,
CUTTING CHASES AND TRENCHES FOR THE INTRODUCTION OF HIS WORK AND
EQUIPMENT IN THE BUILDING SHALL PERFORM OR PAY FOR ALL BACK FILLING,
REPARATION OF WALLS, FLOOR, AND ANY OTHER DAMAGES, BY SUCH COMPANY.
ALL REPAIRS SHALL MATCH EXISTING SURFACES.
12 SEALANTS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
INSTALLATION INSTRUCTIONS IN A WATERTIGHT MANNER. ALL JUNCTIONS
BETWEEN MASONRY, CONCRETE, AND METAL SHALL BE FILLED WITH THE
MANUFACTURER'S RECOMMENDED BACKER ROD TO FORM PROPER SEALANT
PROFILE AND DEPTH.
13 GENERAL CONTRACTOR TO PROVIDE GALVANIC INSULATION BETWEEN
ALL DISSIMILAR METALS.
14 ALL NEW CONSTRUCTION ADJACENT TO EXISTING CONSTRUCTION SHALL
BLEND TO MEET THE EXISTING CONDITIONS, AND THERE SHALL NOT BE ANY
ABRUPT CHANGES IN SURFACES OR UNFINISHED SURFACES.
15 SPECIALTIES: FINISH HARDWARE/PLUMBING FIXTURES AND BATHROOM
ACCESSORIES TO BE SELECTED BY OWNER/ARCHITECT AND FURNISHED AND
INSTALLED BY CONTRACTOR U.N.O. (SEE SCHEDULES AND INTERIOR
ELEVATIONS.)
16 NO SUBSTITUTIONS ARE ALLOWED FOR MATERIALS WHERE SPECIFIC
MANUFACTURERS ARE INDICATED, UNLESS APPROVED BY THE
OWNER/ARCHITECT. REQUESTS FOR SUBSTITUTIONS SHALL BE MADE IN
WRITING PRIOR TO ORDERING MATERIALS OR COMMENCING WORK. SUCH
REQUESTS SHALL INCLUDE THE DATE, SCOPE OF WORK, ANY ADDITIONAL
COSTS TO THE OWNER, AND ANY ANTICIPATED DELAYS CAUSED BY SUCH
CHANGES.
17 NO EXTRA WORK OR CHANGE SHALL BE MADE UNLESS A WRITTEN
CHANGE ORDER IS SUBMITTED AND SIGNED BY THE OWNER AND ARCHITECT.
THE ORDER SHALL STATE THAT THE OWNER HAS AUTHORIZED THE EXTRA
WORK OR CHANGE. AND NO CLAIM FOR AN ADDITIONAL SUM SHALL BE VALID
UNLESS SO OFFERED AS DESCRIBED ABOVE.
18 UNLESS OTHERWISE NOTED, PROVIDE ALL MISCELLANEOUS FASTENERS,
HARDWARE AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
EVEN THOUGH SUCH ITEMS MAY NOT HAVE BEEN SPECIFICALLY MENTIONED IN
THE DRAWINGS AND SPECIFICATIONS, NOTIFY THE OWNER/ARCHITECT OF ANY
REVISIONS OR ADDITIONAL INFORMATION OBTAINED FROM THE
MANUFACTURER OF SPECIFIED MATERIALS OR EQUIPMENT THAT MAY AFFECT
THE CONTRACT TIME, COST, OR QUALITY OF WORK.
19 CLEANING: DURING CONSTRUCTION: GENERAL CONTRACTOR TO
OVERSEE CLEANING AND ENSURE THAT BUILDING GROUNDS ARE MAINTAINED
FREE FROM ACCUMULATIONS OF WASTE MATERIALS AND RUBBISH. REMOVE
WASTE MATERIALS, RUBBISH, AND DEBRIS DAILY FROM THE SITE AND LEGALLY
DISPOSE OF AT PUBLIC OR PRIVATE DUMPING AREAS OFF THE JOB SITE.
SPECIAL CLEANING: BESIDES GENERAL BROOM CLEANING, PERFORM THE
FOLLOWING SPECIAL CLEANING AT THE COMPLETION OF WORK (FOR ALL
TRADES) USING ONLY CLEANING MATERIAL RECOMMENDED BY MANUFACTURER
OF SURFACE TO BE CLEANED AND ONLY ON SURFACES RECOMMENDED BY
CLEANING MATERIAL MANUFACTURER: REMOVE PUTTY STAINS AND PAINT FROM
ALL GLASS. CARE SHALL BE TAKEN NOT TO SCRATCH GLASS. REMOVE ALL
MARKS, STAINS, FINGERPRINTS, AND OTHER SOIL AND/OR DIRT FROM ALL
PAINTED, DECORATED AND STAINED WORK. CLEAN AND POLISH ALL
HARDWARE AND FIXTURES FOR ALL TRADES UPON COMPLETION, INCLUDING
REMOVAL OF ALL STAINS, DUST, ETC.
20 ALL WORKMANSHIP AND MATERIALS SHALL BE GUARANTEED FOR A
PERIOD OF ONE YEAR FROM THE DATE OF CERTIFICATE OF OCCUPANCY UNLESS
SPECIFIED FOR A LONGER PERIOD OF TIME ON SPECIFIED ITEMS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING OR REPAIRING HIS OWN
DEFECTIVE WORK AS WELL AS PAY ALL COSTS INCIDENTAL THERETO
INCLUDING DAMAGE TO OTHER WORK, FURNISHINGS OR EQUIPMENT. ALL
WARRANTIES OR GUARANTEES AS TO MATERIALS OR WORKMANSHIP ON OR
WITH RESPECT TO THE OWNERS WORK SHALL BE CONTAINED IN THE
CONTRACT OR SUBCONTRACT, WHICH SHALL BE SO WRITTEN THAT SUCH
GUARANTEE OR WARRANTIES SHALL INSURE TO THE BENEFIT OF OWNER.
21 INSURANCE: PRIOR TO THE COMMENCEMENT OF WORK THE GENERAL
CONTRACTOR SHALL DELIVER TO THE OWNER CERTIFICATES OF INSURANCE
FOR BOTH COMPREHENSIVE GENERAL LIABILITY AND WORKMAN'S
COMPENSATION INCLUDING THE TOTAL AMOUNT OF COVERAGE AND
CONDITIONS STIPULATED AND AGREED BY BOTH PARTIES.
22 THE OWNER SHALL BE RESPONSIBLE FOR PAYING THE BUILDING PERMIT
FEE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL OTHER
PERMITS REQUIRED OR NECESSARY FOR THE COMPLETION OF THE WORK FROM
THE RESPECTIVE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE GOVERNING
AGENCIES AS REQUIRED FOR INSPECTION OF THE WORK TO BE INSTALLED.
23 ALL MATERIALS AND EQUIPMENT INCORPORATED IN THE CONSTRUCTION
SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S WRITTEN
INSTRUCTIONS.
24 ALL PRODUCTS SHOWN OR SPECIFIED IN THIS DOCUMENT SHALL BE
SUBMITTED TO THE ARCHITECT AND THE OWNER FOR APPROVAL. THE
CONTRACTOR SHALL PROVIDE SAMPLES OF ALL FINISHES TO THE ARCHITECT
AND OWNER FOR APPROVAL BEFORE INSTALLATION.
25 ALL TRADES SHALL REFER TO THE ARCHITECTURAL DRAWINGS
REGARDING LOCATIONS OF WORK TO BE INSTALLED.
26 DRAFTSTOPPING SHALL BE INSTALLED TO SUBDIVIDE COMBUSTIBLE
FLOOR/CEILING ASSEMBLIES SO THAT HORIZONTAL FLOOR AREAS DO NOT
EXCEED 1,000 SF PER 2018 INTERNATIONAL RESIDENTIAL CODE R302.12.
27 THESE DRAWINGS ARE TO BE DESIGN -BUILD FOR MECHANICAL,
ELECTRICAL, AND PLUMBING TRADES U.O.N. THE GENERAL CONTRACTOR IS
RESPONSIBLE FOR COORDINATING THE TRADES AND NOTIFYING THE
OWNER/ARCHITECT OF ANY CONFLICTS PRIOR TO THE BEGINNING OF WORK
FOR OWNER/ARCHITECT APPROVAL. WHEREVER POSSIBLE, FRAMING MEMBERS
ARE TO BE LOCATED TO ACCOMMODATE THE WORK OF THESE TRADES.
28 ALL PIPING AND CONDUIT UNDER SLAB SHALL BE A MINIMUM OF 2'-0"
CLEAR OF UNDERSIDE OF FOOTING.
29 ALL FINAL SURFACE GRADING SHALL BE COMPLETED TO FACILITATE
POSITIVE DRAINAGE AWAY FROM THE BUILDING UNLESS NOTED OTHERWISE.
30 PRIOR TO AND DURING THE WORK, CONTRACTOR SHALL VERIFY
CONDITIONS; ANY CONDITIONS INCONSISTENT OR PROBLEMATIC WITH
REGARDS TO THE INTENT OF THE DRAWINGS SHALL BE BROUGHT TO THE
ATTENTION OF THE OWNER/ARCHITECT PRIOR TO STARTING OR CONTINUING
WORK IN THE AREA CONCERNED.
31 CONTRACTOR TO ASSUME ALL MATERIALS ARE TO BE NEW UNLESS
NOTED AS EXISTING.
32 FLASH OPENINGS WITH MIN. 26 GA. GALV. STEEL TO ACCEPTABLE
INDUSTRY STANDARDS. ALL FLASHING LAP SEAMS TO BE 12 MIN. W/ 2 BEADS
OF SEALANT. PRE -FINISHED FLASHING, TYP.
33 ALL UNDERGROUND UTILITIES MUST BE VERIFIED AS TO EXACT
LOCATIONS SO AS NO INTERFERENCE BY DISRUPTION WILL BE CAUSED.
GENERAL CONTRACTOR SHALL PROTECT EXISTING FACILITIES, STRUCTURES
AND UTILITIES. DAMAGE THAT MAY BE CAUSED BY THE GENERAL CONTRACTOR
OR ANY SUB CONTRACTOR TO ANY OF THE ABOVE MENTIONED SHALL BE
REPAIRED BY GENERAL CONTRACTOR AND LEFT IN AS GOOD A CONDITION AS
EXISTED PRIOR TO DAMAGING.
34 PROVIDE WATERPROOFING ON BELOW GRADE CONCRETE, PER SPEC.
INSTALL DRAINAGE MAT OVER WATERPROOFING, PER SPEC.
35 NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED
FOR STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
36 PROVIDE GFI PROTECTION @ RECEPTACLES IN BATHS, KITCHEN,
OUTDOOR AND OTHER WET LOCATIONS.
37 PROVIDE SUFFICIENT BLOCKING IN WALLS FOR SUPPORTING COUNTERS,
CABINETS, ACCESSORIES, ETC. AS REQUIRED.
38. CONDUCT ASBESTOS SURVEY, IF THE DEMOLISHED STRUCTURE INCLUDES
48SQFT OR 10LIN FT OF ABESTOS-CONTAINING MATERIAL, A NOTIFICATION
MUST BE FILED TO ORCAA AT LEAST 10 DAYS BEFORE WORK BEGINS.
R I C H A R T Z
S T U D I O S
I N C
ARCHITECT:
RICHARTZ STUDIOS, INC.
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T: 206 784 9652
F: 206 913 2432
CONTACT:
KEVIN RICHARDS, ARCHITECT
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T:206 784 9652
kevin@richartzstudios.com
6964
REGISTE?.ER
'i y v V, r VV/ V
J M. RICE ARI?�
OF WASNINGTON
WHITE
RESIDENCE
8226 187TH ST SW
EDMONDS, WA 98026
PERMIT DRAWINGS
DATE: OCT 31ST, 2023
PROJECT# :
REF#:
SCALE: AS NOTED
DESIGNED: KR RECEIVED
DRAWN: YS Nov 06 2023
REVIEWED: KR CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
COVER SHEET &
GENERAL NOTES
A0.O
0
N
X
w
aj
aj
tn
Ln
Q
(E) CRAWLSPACE ACCESS AT
FOUNDATION WALL
DEMO EX. SHOWER
LL
DEMO EX. SINKS
N�
N
-H
X
w
(E) WINDOW TO REMAIN
DEMO EX. TUB
DEMO PLAN
SCALE: 1/4" = 1'-0"
NORTH
LEGEND:
NEW WALL
0 EX. WALL, TO REMAIN
C EX. WALL, TO BE REMOVED
�F VENTILATION FAN
- 0 WALL TYPE TAG
ooi FLOOR TYPE TAG
NnTFC,-
1. ALL EX. EXTERIOR WINDOWS AND DOORS TO
REMAIN
2. ALL EX. CEILINGS TO REMAIN
3. ALL EX. EXTERIOR WALLS TO REMAIN, EXCEPT
FOR INTERIOR FINISHES PER WALL TYPE 2&3
4. ALL EX. FLOORS TO REMAIN, EXCEPT FOR
MASTER BATHROOM
5. NO CHANGE TO EX. WALLS BETWEEN DWELLIN
AND GARAGE
6. ALL EX. SMOKE AND CARBON MONOXIDE
ALARMS TO REMAIN
7. ALL EX. HVAC SYSTEM TO REMAIN
8. ALL ARCHITECTURAL MEASUREMENTS ARE
FROM FINISH TO FINISH, U.O.N.
R I C H A R T Z
S T U D I O S
I N C
ARCHITECT:
RICHARTZ STUDIOS, INC.
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T: 206 784 9652
F: 206 913 2432
CONTACT:
KEVIN RICHARDS, ARCHITECT
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T:206 784 9652
kevin@richartzstudios.com
W
WHITE
RESIDENCE
8226 187TH ST SW
EDMONDS, WA 98026
PERMIT DRAWINGS
DATE: OCT 31ST, 2023
PROJECT# :
REF#:
SCALE: AS NOTED
DESIGNED: KR RECEIVED
DRAWN: YS Nov 06 2023
REVIEWED: KR CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
DEMO
�,W.,0�
A200
Q
u
z
0
0
Ln
a
0
V
(E) CRAWLSPACE ACCESS AT
FOUNDATION WALL TO REMAIN
CABINET UNDERNEATH
(2) UNDERCOUNTER SINKS
(2) DECK -MOUNTED FAUCETS
VANITY MIRROR W/
-'
MEDCINE CABINET
LL:
VANITY MIRROR
-
OPEN UNDERNEATH
END PANEL
N
+
=
TOWEL BAR
-'
CURVED SHOWER CURTAIN
X
w
(E) WINDOW TO REMAIN
_ FOLDING BENCH
ROLL -IN SHOWER
(REFRAMED FLOOR TO BE DEPRESSED)
LINEAR SHOWER DRAIN S-AG 3860
OR EQUIVALENT, F.V. DIMENSIONS
GRAB BARS
E) MASTER BEDROOM
EX. f7-11ill , F.V.
'-10"
EX.
up
F
001
MA TER
BATHROOM
TILE ALIGN
LL
002
t0
II
II
I
FOLDING GRAB R
GRAB BAR
(E) CABINET T REMAIN
FOYER
(E) WOOD
FU -HEIGh
L EN CAB.
32"X80" DOOR, MATCH EX., F.V.
(E) HEATER, REPLACE THE GRILLE
TO AG10 OR EQUIVALENT
(E) BEDROOM
PATCH THE WOOD FLOOR AS RQRI
RELOCATE POCKET DOOR
REUSE EX. DOOR & HARDWARE
40"X80" DOOR, MATCH EX. WIDEN
DOOR OPENING, REUSE EX.
HINGE & HARDWARE
1 4 SIM 4 (E) HALLWAY
II
(E) ATTIC ACCESS TO REMAIN, 30"X32"
1- 11
��-- --�
E) BEDROOM I I I I (E) POWDER
FLOOR ASSEMBLY:
ool - OWNER SPECIFIED TILE
- UNDERLAYMENT & (E) HEATING MAT
- (E) CAR DECKING
- (E) FLOOR FRAMING
W/ R-30 BATT INSULATION AS REQ'D
0o2 - OWNER SPECIFIED STONE SLAB
- MORTAR BED, F.V. THICKNESS
- WATERPROOF MEMBRANE
- HEATING MAT AS NEEDED
- PRE -SLOPED MORTAR BED @ 4" / FT.
- PLYWD SUBFLOOR PER STRUCT.
- FLOOR FRAMING PER STRUCT.
W/ R-30 BATT INSULATION FILLED AS REQ'D
(E) BATHROOM I I (E) FURNACE
nr%r,nn
WALL ASSEMBLY:
- (E) DRYWALL
- (E) FRAMING
- 1/2" CEMENT BOARD
- OWNER SPECIFIED FINISH
- 1/2" DRYWALL
- 2X4 FRAMING @16" O.C.
- 1/2" CEMENT BOARD
- OWNER SPECIFIED FINISH
- (E) EXTERIOR FINISH
- (E) WRB
- (E) SHEATHING
- (E) FRAMING W/ INSULATION
- 1/2" CEMENT BOARD
- OWNER SPECIFIED FINISH
FLOOR PLAN
SCALE: 1/4" = V-0"
E W/D
CLOSET
I
(E) WATER
1 IrATrP1
CLOSET
- (E) EXTERIOR FINISH
- (E) WRB
- (E) SHEATHING
- (E) FRAMING W/ INSULATION
- (E) DRYWALL
E KITCHE
DINING ROOM
DEMO EX. TILE AND UNDERLAYMENT,
�I ADD NEW 1/2" DRYWALL
- (E) DRYWALL
- (E) FRAMING
- (E) DRYWALL
DEMO EX. TILE AND UNDERLAYMENT,
�y ADD NEW 1/2" DRYWALL
- 1/2" DRYWALL
- FLAT 2X4 FRAMING @ 16" O.C.
- 1/2" DRYWALL
NORTH
LIVING ROOM
E PORCH
STORAGE ROOM
FAMILY ROOM
(E) GARAGE
LEGEND:
0
NEW WALL
0
EX. WALL, TO REMAIN
EX. WALL, TO BE REMOVED
�F
VENTILATION FAN
-
WALL TYPE TAG
ool
FLOOR TYPE TAG
nir�Trr.
1. ALL EX. EXTERIOR WINDOWS AND DOORS TO
REMAIN
2. ALL EX. CEILINGS TO REMAIN
3. ALL EX. EXTERIOR WALLS TO REMAIN, EXCEPT
FOR INTERIOR FINISHES PER WALL TYPE 2&3
4. ALL EX. FLOORS TO REMAIN, EXCEPT FOR
MASTER BATHROOM
5. NO CHANGE TO EX. WALLS BETWEEN DWELLING
AND GARAGE
6. ALL EX. SMOKE AND CARBON MONOXIDE
ALARMS TO REMAIN
7. ALL EX. HVAC SYSTEM TO REMAIN
S. ALL ARCHITECTURAL MEASUREMENTS ARE
FROM FINISH TO FINISH, U.O.N.
R I C H A R T Z
S T U D I O S
I N C
ARCHITECT:
RICHARTZ STUDIOS, INC.
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T: 206 784 9652
F: 206 913 2432
CONTACT:
KEVIN RICHARDS, ARCHITECT
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T:206 784 9652
kevin@richartzstudios.com
6964
REGISTERED
.J (/ V V ' Y v(/ V
J M. RICE 4RDS
OF WASHINGTON
WHITE
RESIDENCE
8226 187TH ST SW
EDMONDS, WA 98026
PERMIT DRAWINGS
DATE: OCT 31ST, 2023
PROJECT# :
REF#:
SCALE: AS NOTED
DESIGNED: KR RECEIVED
DRAWN: YS Nov 06 2023
REVIEWED: KR CITY OFEDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
FLOOR
PLAN
A2m 1
u
z
0
0
Q
u
r
a
0
V
GENERAL STRUCTURAL NOTES:
CRITERIA
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2018
EDITION).
2. DESIGN LOADING CRITERIA:
FLOOR LIVE LOAD . . . . . . . . . . . . . . . . . . . . . . . . 40 PSF
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS FOR BIDDING AND CONSTRUCTION. ARCHITECTURAL DRAWINGS ARE THE
PRIME CONTRACT DRAWINGS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE
SPECIFICATION, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE
REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING.
ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH
DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK.
4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND
DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL
DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING
SECTION, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL
ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE
CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY
AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING
CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS
OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT,
SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO
THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE.
6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN
ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-14 "DESIGN LOADS ON
STRUCTURES DURING CONSTRUCTION".
7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE
ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR
CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS
REQUIREMENT.
8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO
REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL
TYPICAL NOTES AND DETAILS SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED
OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS
BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE
TYPICAL DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL
SHALL BE USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM
THOSE PROVIDED OR REQUEST ADDITIONAL INFORMATION. THE CONTRACTOR SHALL
SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH
RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING
PRODUCTION AND FIELD USE.
RENOVATION
9. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE
COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT
EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK
SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD
THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION
DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF.
10.CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING
CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND
MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND
STRUCTURAL ENGINEER IF EXISTING CONDITIONS DETERMINED DURING WORK VARY
FROM THE EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS.
11.CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL
ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS
DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT.
WOOD
12.FRAMING LUMBER SHALL BE S-DRY, KD, OR MC-19, AND GRADED AND MARKED
IN CONFORMANCE WITH WCLIB STANDARD NO. 17, GRADING RULES FOR WEST COAST
LUMBER, 2018, OR WWPA STANDARD, WESTERN LUMBER GRADING RULES 2017.
FURNISH TO THE FOLLOWING MINIMUM STANDARDS:
JOISTS (2X & 3X MEMBERS) HEM -FIR NO. 2
AND BEAMS MINIMUM BASE VALUE, FB = 850 PSI
(4X MEMBERS) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, FB = 1000 PSI
BEAMS (INCL. 6X AND LARGER) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, FB = 1350 PSI
POSTS (4X MEMBERS) DOUGLAS FIR -LARCH NO. 2
MINIMUM BASE VALUE, FC = 1350 PSI
(6X AND LARGER) DOUGLAS FIR -LARCH NO. 1
MINIMUM BASE VALUE, FC = 1000 PSI
STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR -LARCH NO. 2
OR HEM -FIR NO. 2
13.PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL
II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTED STRAND
BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE
USED IN LIEU OF PLYWOOD.
ROOF SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 32/16.
FLOOR SHEATHING SHALL BE 3/4" (NOMINAL) WITH SPAN RATING 48/24.
WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0.
PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT
UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE
APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW
1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING.
REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS.
14.ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT
IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND
CONCRETE OR MASONRY.
15.PRESERVATIVE TREATED WOOD SHALL BE TREATED PER AWPA STANDARD U1 TO
THE USE CATEGORY EQUAL TO OR HIGHER THAN THE INTENDED APPLICATION.
TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO AWPA UC3B. WOOD IN
CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO AWPA
UC4A. WOOD FOR USE IN PERMANENT FOUNDATIONS SHALL BE TREATED TO AWPA
UC4B.
16.FASTENERS AND TIMBER CONNECTORS USED WITH TREATED WOOD SHALL HAVE
CORROSION RESISTANCE AS INDICATED IN THE FOLLOWING TABLE, UNLESS
OTHERWISE NOTED.
WOOD TREATMENT CONDITION PROTECTION
HAS NO AMMONIA CARRIER INTERIOR DRY G90 GALVANIZED
CONTAINS AMMONIA CARRIER INTERIOR DRY G185 OR A185 HOT DIPPED OR
CONTINUOUS HOT -GALVANIZED
PER ASTM A653
CONTAINS AMMONIA CARRIER INTERIOR WET TYPE 304 OR 316 STAINLESS
CONTAINS AMMONIA CARRIER EXTERIOR TYPE 304 OR 316 STAINLESS
AZCA ANY TYPE 304 OR 316 STAINLESS
INTERIOR DRY CONDITIONS SHALL HAVE WOOD MOISTURE CONTENT LESS THAN 19%.
WOOD MOISTURE CONTENT IN OTHER CONDITIONS (INTERIOR WET, EXTERIOR WET,
AND EXTERIOR DRY) IS EXPECTED TO EXCEED 19%. CONNECTORS AND THEIR
FASTENERS SHALL BE THE SAME MATERIAL. COMPLY WITH THE TREATMENT
MANUFACTURERS RECOMMENDATIONS FOR PROTECTION OF METAL.
17.TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE
"STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER
C-C-2021. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED,
PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES.
PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR
MAXIMUM LOAD CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST
HANGERS. ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITS"
SERIES JOIST HANGERS. ALL DOUBLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH
BEAMS WITH "MIT" SERIES JOIST HANGERS.
WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS
OR BOLTS IN EACH MEMBER.
ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM)AS
MEMBERS CONNECTED.
18.WOOD FASTENERS
A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING
SPECIFICATIONS:
SIZE LENGTH DIAMETER
6D 2" 0.113"
8D 2-1/2" 0.131"
10D 3" 0.148"
12D 3-1/4" 0.148"
16D BOX 3-1/2" 0.135"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT
NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)
FOR REVIEW AND APPROVAL.
NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE
DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED.
TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER
AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END.
B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS
UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD.
INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70
PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8"
AND SMALLER LAG SCREWS.
19.NOTCHES AND HOLES IN WOOD FRAMING:
A. NOTCHES ON THE ENDS OF SOLID SAWN JOISTS AND RAFTERS SHALL NOT EXCEED
ONE-FOURTH THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF SOLID SAWN
JOISTS SHALL NOT EXCEED ONE -SIXTH THE DEPTH AND SHALL NOT BE LOCATED
IN THE MIDDLE THIRD OF THE SPAN. HOLES BORED IN SOLID SAWN JOISTS AND
RAFTERS SHALL NOT BE WITHIN 2 INCHES OF THE TOP OR BOTTOM OF THE JOIST,
AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED ONE-THIRD THE DEPTH
OF THE JOIST.
B. IN EXTERIOR WALLS AND BEARING PARTITIONS, ANY WOOD STUD IS PERMITTED
TO BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25 PERCENT OF ITS WIDTH.
A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD WIDTH IS
PERMITTED TO BE BORED IN ANY WOOD STUD. IN NO CASE SHALL THE EDGE OF
THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE EDGE OF THE STUD. BORED
HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR
NOTCH.
C. NOTCHES AND HOLES IN MANUFACTURED LUMBER AND PREFABRICATED PLYWOOD WEB
JOISTS SHALL BE PER THE MANUFACTURERS RECOMMENDATIONS UNLESS OTHERWISE
NOTED.
20.WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON
THE PLANS:
A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO
THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC
"TIMBER CONSTRUCTION MANUAL" AND THE AWC "NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, UNLESS
OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304.10.1. COORDINATE THE
SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL
DRAWINGS.
B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS.
ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE
PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND
AT BEAM OR HEADER BEARING LOCATIONS. TWO 2X8 HEADERS SHALL BE PROVIDED
OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS
SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS
SOLID BLOCKING AT MID -HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT.
ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END
NAIL TOP PLATE TO EACH STUD WITH TWO 16D NAILS, AND TOENAIL OR END
NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16D NAILS. FACE NAIL DOUBLE
TOP PLATE WITH 16D @ 12" O.C.. LAP TOP PLATES AT JOINTS A MINIMUM
4'-0" AND NAIL WITH TWELVE 16D NAILS @ 4" O.C. EACH SIDE JOINT.
ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD
FRAMING BELOW WITH TWO ROWS OF 16D NAILS @ 12" ON -CENTER, OR ATTACHED
TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON -CENTER
EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF
BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16D @12"
ON -CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED
TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4"
TYPE S OR W SCREWS @ 8" ON -CENTER. UNLESS INDICATED OTHERWISE, 1/2"
(NOMINAL)APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL
EXTERIOR SURFACES WITH 8D NAILS @ 6" ON -CENTER AT PANEL EDGES AND TOP
AND BOTTOM PLATES (BLOCK UN -SUPPORTED EDGES)AND TO ALL INTERMEDIATE
STUDS AND BLOCKING WITH 8D NAILS @ 12" ON -CENTER ALLOW 1/8" SPACING AT
ALL PANEL EDGES AND PANEL ENDS.
C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL
PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND
ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID
BLOCKING BETWEEN RAFTERS AND JOISTS AT ALL BEARING POINTS WITH A
MINIMUM OF (3) 16D TOE NAILS EACH END. TOE -NAIL JOISTS TO SUPPORTS
WITH TWO 16D NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS
WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL
ALL MULTI JOIST BEAMS TOGETHER WITH TWO ROWS 16D @ 12" ON -CENTER.
UNLESS OTHERWISE NOTED ON THE PLANS, PLYWOOD ROOF AND FLOOR SHEATHING
SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED AT 6"
ON -CENTER WITH 8D NAILS TO FRAMED PANEL EDGES, STRUTS AND OVER STUD
WALLS AS SHOWN ON PLANS AND @ 12" ON -CENTER TO INTERMEDIATE SUPPORTS.
PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT
UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE
APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW
1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING.
TOENAIL BLOCKING TO SUPPORTS WITH 16D @ 12" ON -CENTER, MINIMUM TWO
NAILS PER BLOCK, UNLESS OTHERWISE NOTED.
D. WOOD SHRINKAGE: MECHANICAL, ELECTRICAL, PLUMBING FIRE PROTECTION,
CLADDING, AND OTHER SYSTEMS INSTALLED WITHIN THE BUILDING SHALL BE
DESIGNED AND CONSTRUCTED TO ACCOMMODATE 3/8" OF VERTICAL MOVEMENT PER
FLOOR LEVEL
PLAN NOTES
1. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR ALL
DIMENSIONS.
2. REFER TO GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.
3. EXISTING FRAMING ON PLANS IS ASSUMED. CONTRACTOR TO VERIFY DIRECTIONS
AND EXTENTS. NOTIFY ARCHITECT AND ENGINEER IF DIFFERENT.
4. TYPICAL FLOOR FRAMING CONSISTS OF FLOORING PER ARCHITECT OVER 3/4" T&G
APA RATED PLYWOOD FACE GRAIN PERPENDICULAR TO FRAMING PER PLAN, U.O.N.
5. NAIL FLOOR SHEATHING W/ 8D AT 6" OC AT FRAMED PANEL EDGES AND OVER
SHEARWALLS, AND AT 12" OC IN FIELD.
(2) LS70 - ONE EACH
SIDE OF BEAM
2X8 @16" O.C., w/ LUS EA END
HUC48 w/ 4"0 x1- 4" TITEN
TURBO CONC. SCREWS
(2) LS70 - ONE EACH
SIDE OF BEAM
(E) CONC. FOUNDATION
(E) 4x4 POSTS &FTGS.
(E) 4X8 FLOOR JOISTS
(E) 4x4 POSTS &FTGS.
FLOOR FRAMING PLAN 0 1' 2' 41 8'
SCALE: 1/4" = V-0"
NORTH
R I C H A R T Z
S T U D 1 0 S
I N C
ARCHITECT:
RICHARTZ STUDIOS, INC.
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T: 206 784 9652
F: 206 913 2432
CONTACT:
KEVIN RICHARDS, ARCHITECT
2300 WEST COMMODORE WAY, #201
SEATTLE, WA 98199
T:206 784 9652
kevin@richartzstudios.com
WHITE
RESIDENCE
8226 187TH ST SW
EDMONDS, WA 98026
PERMIT DRAWINGS
DATE: OCT 13TH, 2023
PROJECT# :
REF#:
SCALE: AS NOTED
DESIGNED: KR RECEIVED
DRAWN: YS Nov 06 2023
REVIEWED: KR CITY OFEDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
STRUCTURAL
PLAN
S2mO