Loading...
REVIEWED-BLD2022-1233+Structural_Calculations+9.15.2022_1.14.27_PM+3110911Page 1 of 29 LONGITUDE ONE TWENTYO ENGINEERING & DESIGN Structural Package for: Folk Residence Addition 8718 242nd Street SW Edmonds, WA 98026 Project No: S220527-2 August 30, 2022 RECEIVED Sep 20 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1233 ................................................ REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT L120 ENGINEERING & DESIGN 13150 91 ST PL N E KIRKLAND, WA 98034 CONTACT: MANS THURFJELL, PE PHONE: 425-636-3313 MTHURFJELL@Ll20ENGINEERING.COM A LONGITUDE ONE TWEoNTYo es era Remodel /Addition Narrative: Page 2 of 29 The Folk Residence is a single -story, Z097-SF residence located in Edmonds, Washington. The proposed addition includes two parts: 1. A single story exterior deck roof, 190-SF. 2. Interior bearing (assumed) and non -bearing wall removal and re -support at the dining and kitchen. 2. A single story addition, 500-SF (24% addition) The roof of the exterior deck roof addition will have new footings and gravity support and be braced by the main structure. Due to the light weight of the roof and it's miniscule size relative to the main, heavier structure, this adds less then 5% shear to the building, thus meeting the requirements of WSEBC noted below. The removed non -bearing walls are not impactful, structurally. The removed bearing wall at the south of the dining room will be fitted with a new header, and posts and footings will be added to the crawl space. The 500-sf single story addition will be framed with new roof truss /rafter framing and crawl space floor framing over conventional bearing foundations. Due to its relative stiffness, the behavior of flexible diaphragms, and isolated behavior, the structure is designed to be laterally self-supporting. All walls used are stressed at most up to 113 of their available shear capacity by the addition and thus increase the overall shear capacity of the building. Existing soils are assumed to be compatible with conventional foundations that exist and 1500 PSF will be assumed for the soil bearing capacity. SECTION 1103 STRUCTURAL CBS] 1103.1 Addrti,nal gravity loads. Any existing gm,dy load -carrying structural element for which an addition and Its related attentions cause an increase In design dead, We o snow load, including snow drift effects, of more than 5 percent shall be replaced or altered as needed to carry the gravity loads required by the International Building Code for new structures. Any existing gravity load -carrying structural element whose gravity load -carrying capacity is decreased as part of the addition and its related alterations shall be considered to be an altered element subject to the requirements of Section 806.2. Any a asting element that will form part of the lateral load path for any part of the addition shall be considered to be an existing lateral bad -carrying structural element subject to the requirements of Section 1103.3. Exception: Buildings of Group R occupancy with not more than five dwelling units or sleeping units used solely for residential purposes where the existing building and the addition together comply wan the conventional lightframe construction methods of the International Building Code or the provisions of the Infemafional Residential Code. CBS] 1103.2 Lateran torte-restsang system. Where the audit,,, is structurally independent of the existing Structure, existing lateral loa l-mi rig structural elements shall be permitted to remain unaltered. Where the addition is not structurally independent of the existing struttum, the existing structure and its addition acting together as a single structure shall meet the requirements of Sections 1609 and 1613 of the International Building Code using full seismic forces. Exceptions- 1 Buildings of Group R —pancy with not more than five dwelling or sleeping units used solely for residential purposes where the existing building and the audition comply with the conventional lightmainconstruction methods of the I,femaflonal Building Coda or the provisions of the International Residential Code. 2. Any existing lateral load —hying structural element whose demand -capacity, ratio with the addition considered is not more than 10 percent greater than its demand_capaciN tali, with the addition ignored shall be permitted to remain unaftemd. For purposes of calculating demand—pacity reties, the demand shall consider applicable load combinations with design lateral leads or forces in accordance with Sections 1609 and 1613 of the International Building Code. For purposes of this exception, comparisons of demand -capacity ratios and calculation of design lateral loads, forces and capacities shall account for the cumulative effects of additions and alterations since original construction. Page 3 of 29 OSH PD Folk Residence Addition 8718 242nd St SW, Edmonds, WA 98026, USA Latitude, Longitude: 47.7793274,-122.3508076 Do J D 0 Du Do s f2nd St SW a� a Campbell Auto Grou -0 Denny's CV ON �,^t 99 Go gi&ond Park Station _ neap data 02022 Date 8/23/2022, 4:30:26 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Stiff Soil Type Value Description SS 1.277 MCER ground motion. (for 0.2 second period) S1 0.448 MCER ground motion. (for 1.0s period) SMs 1.277 Site -modified spectral acceleration value SM1 - 11.4.8 0.830 Site -modified spectral acceleration value SDS 0.851 Numeric seismic design value at 0.2 second SA SD1 11.4.8 0.553 Numeric seismic design value at 1.0 second SA Type Value Description SDC qq.4.8 D Seismic design category Fa 1 Site amplification factor at 0.2 second Fv 11.48 1.852 Site amplification factor at 1.0 second PGA 0.542 MCEG peak ground acceleration FPGA 1.1 Site amplification factor at PGA PGAM 0.596 Site modified peak ground acceleration TL 6 Long -period transition period in seconds SsRT 1.277 Probabilistic risk -targeted ground motion. (0.2 second) SsUH 1.401 Factored uniform -hazard (2 % probability of exceedance in 50 years) spectral acceleration SsD 1.973 Factored deterministic acceleration value. (0.2 second) S1 RT 0.448 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.499 Factored uniform -hazard (2 % probability of exceedance in 50 years) spectral acceleration. S1 D 0.788 Factored deterministic acceleration value. (1.0 second) PGAd 0.696 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.542 Uniform -hazard (2 % probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.912 Mapped value of the risk coefficient at short periods CR1 0.896 Mapped value of the risk coefficient at a period of 1 s Cv 1.355 vertical coefficient Site specific ground motion procedure per ASCE7-16 Section 11.4.8 NOT REQUIRED Ref exception 2 of 11.4.8 Page 3 of 29 Page 4 of 29 Project Number: Plan Name: Sheet Number: S220624-4 Folk Residence Addition DC Engineer: Specifics: ate: SB Design Criteria 8/30/2022 Gravity Criteria: IBLUE = Review and update as required - Typical Input I Code: IBC 2018 ROOF SYSTEM Live Load: Snow 25.0 psf Dead Load: Composite Roofing 2.0 psf 19/32" Plywood Sheathing 2.5 psf Trusses at 24" o.c. 3.5 psf Insulation 1.8 psf (1) Layers 5/8" GWB 2.8 psf Misc or Tile Roof 2.4 psf Total 15.0 psf SEISMIC PARAMETERS: Code Reference: R= Mapped Spectral Acceleration, Ss = Mapped Spectral Acceleration, S 1 = Soil Site Class = WIND PARAMETERS: ASCE 7-16 6.5 Bearing Wall System, Wood Structural Panel Walls 1.277 0.448 D Site specific soils report not required Exception 2 of 11.4.8 Code Reference: ASCE 7-16 Basic Wind Speed (3 second Gust) = 100 mph Exposure : B Kzt = 1.00 (Per seattle wind speed factor maps)\ SOIL PARAMETERS: Soil Bearing Pressure = 1,500 psf competent native soil or structural fill 1/3 increase for short-term wind or seismic loading is acceptable Frost Depth = 18 in Page 4 of 29 Page 5 of 29 LONGITUDE ONE TWENTYO ENGINEERING & DESIGN LATERAL CALCULATIONS WALL REFERENCE PER PLAN Existing to remain, typical unless noted otherwise Page 6 of 29 ProjectNumber:SheetNumber: S220624-4 Folk Residence Addition LI Engineer: Specifics: Date SB WIND FORCES 8/30/2022 IBC 2018 Section 1609 , ASCE 7-16 Section 28.5 - Simplified Procedure , Main Wind -Force Resisting System WIND DESIGN CRITERIA: Basic Wind Speed, V, = 100 mph (ASCE 7-16, Section 26.5) Exposure = B (ASCE 7-16, Section 26.7) BUILDING DIMENSIONS: Roof Slope = Loads From Front/Back - Width (ft)= Loads From Side - Width (ft) _ Average Eave Height = Mean Roof Ht. , h = Edge Strip Width, a = End Zone Width, 2a = 8.00:12 = 33.69 degrees 20.25 ft Roof: Hip 24.25 ft Roof. Gable 11.25 ft 15.00 ft (ASCE 7-16, Figure 27.5-2) 3 ft (ASCE 7-16, Figure 28.5-1) 6.00 ft (ASCE 7-16, Figure 28.5-1) TOPOGRAPHIC DESIGN CONSIDERATIONS: Topographic Factor, Kzt = 1.00 (ASCE 7-16, Section 26.8) Adjustment Factor, X = 1.00 (ASCE 7-16, Figure 28.5-1) WIND LOAD SUMMARY: 11 Front / Back Direction Roof 1.06 k Basement (Base Shear) 1.06 k Side / Side Direction Roo'' 1.32 k I st Floor (Base Shcar) 1.32 k SIMPLIFIED DESIGN WIND PRESSURE, Psso (psf) qu (Exposure Bath = 3Oft) Basic Wind Speed, Vs (mph) Roof Angle (Degrees) Load Case ZONES* Horizontal Pressure Vertical Presssure Overhang A I B C D E F G H Eon Gon 100 33.69 A 17.80 12.20 14.20 9.80 1.40 1 -10.80 1 0.50 1 -9.30 -6.30 1 -7.20 • Values Interpolated from Figure 28.5-1 ASCE 7-16 Page 6 of 29 Page 7 of 29 ProjectNumber:SheetNumber: S220624-4 Folk Residence Addition LI Engineer: Specifics: Date SB WIND FORCES 8/30/2022 IBC 2018 Section 1609 , ASCE 7-16 Section 28.5 - Simplified Procedure , Main Wind -Force Resisting System HORIZONTAL LOADS (psi) p, _ A* Kzt*Ps30 MIN. LOADS (psi) Per ASCE 7-16, 28.5 End zone Interiorzone Roof Wall A (Wall) B (Roof)P14.4201 D (Roof) 17.80 12.209.80 8.0 16.0 ASD WIND FORCES: FRONT / BACK LOADING DIRECTION End Zone Interior zone Force Min Force Width Height* Length Pressure (W Length Pressure (W Location Plane 0.6 W 0.6 W (ft) (ft) (ft) (Psi) (ft) (psi) (kips) (kips) Roof 20.3 1.00 (roof) 6.0 12.20 14.3 9.80 0.13 0.10 a Plate to Mid 1st LVL 20.3 5.00 (wall) 6.0 17.80 14.3 14.20 0.93 1 0.97 1.06 0.97 Z=1 *Average height Total Wind Base Shear (kips)I 1.06 I 0.97 ASD WIND FORCES: SIDE / SIDE LOADING DIRECTION End Zone Interior zone Force Min Force Width Height Length �ressure (W Length ressure (W Location Plane 0.6 W 0.6 W (ft) (ft) (ft) (Psf) (ft) (psi) kips kips Roof 24.3 1.00 (roof) 6.0 17.80 18.3 14.20 0.22 0.12 Plate to Mid 1st LVL 24.3 5.00 (wall) 6.0 17.80 18.3 14.20 1.10 1.16 1.32 1 1.28 £ = * Width at pl to mid 1st reduced by 8 ft (40 sf) to account for covered Total Wind Base Shear (kips)1 1.32 I 1.28 area 3 x 17 It (51 si) opening tributary to the roof Page 7 of 29 Page 8 of 29 Project Number: Plan Name: Sheet Number: S220624-4 Folk Residence Addition L2 Engineer: Specifics: Date: SB SEISMIC WEIGHTS 8/30/2022 Unit Weights (psf) Seismic Weights include: (REF §12.7) Roof: 15 psf 25% of storage Live loads 10 PSF total wall, 5 for top half of walls Exterior Wall: 5 psf AREA / LENGT LEVEL ITEM H UNIT WEIGHT (psf) Item Total Weight. (lbs) Sub- Total (kips) Average Pressure (psf) ROOF Roof 670 1.14 14.95 = 11,420 Wall 670 1.00 5 = 3,350 15 22 STRUCTURE WEIGHT FOR SEISMIC BASE SHEAR: 15 kips TOTAL WEIGHT OF STRUCTURE: 15 kips (Includes Basement Dead Load) Page 8 of 29 Project Number: Plan Name: Sheet Number: S220624-4 Folk Residence Addition Pa15of29 Engineer: Specifics: Date: SB SEISMIC FORCES 8/30/2022 l quivelant Lateral rorce Analysis per wu 2uIZ5 1013.1 -ANU /-10 Table l2.b-1 -Nec 12.6 Data generated by: Seismic Design Values for Buildin, "Java Ground Motion Parameter Calculation" S1 = 0.448 Maps SDs = 0.851 (ASCE 7 EQ 11.4.-3) SDI = 0.553 (ASCE 7 EQ 11.4.-4) Seismic Importance Factor = 1.00 (ASCE 7 Table 11.5-1) Seismic Design Category = D (ASCE 7 Table 11.6-1 & 11.6.2) Response Modification Factor, R = 6.5 (ASCE 7 Table 12.2-1) Seismic Force -Resisting System Description = A.13 - light framed walls Building Height, hn = Building Period Coefficient, CT = Approx. Fundamental Period, Ta = Approx. Fundamental Period, TL = Seismic Response Coefficient C, = SDs/(R/I) Cs = Seismic Response Coefficient, Maximum Cs MAX = SDI/(T*R/1) Cs, MAX = Cs MAX = SDI TL/(T z *R/ Cs MAX = Seismic Response Coefficient, Minimum Cs, MIN = 0.01 // Cs, MIN Cs MIN = 0.5 S1 / (R/1) Cs MIN = 11.0 ft 0.020 (ASCE 7 Table 12.8.-2) 0.121 (CTO.0.75) (ASCE 7 EQ 12.8.-7) 6.0 sec (ASCE 7 11.4.5) 0.131 0.704 T <_ TL NA T > TL (ASCE 7 EQ 12.8.-2) (ASCE 7 EQ 12.8.-3) (ASCE 7 EQ 12.8.-4) 0.010 (ASCE 7 EQ 12.8.-5) NA if S 1 > 0.6 (ASCE 7 EQ 12.8.-6) Cs = 0.131 Dead Load W = 15 kips V=CsW= 1.9 kips QE = V = 1.9 kips P = 1.0 Ex = P QE 1.9 kips Ev=.2SDSD= 0.17 xD kips Factor for Alternate Basic Load conbinations - 2018 IBC En/1.4 = 1.4 kips k= 1 (ASCE 7 EQ 12.8A) (ASCE 7 EQ 12.4-3) (ASCE 7 12.3.4.2) (ASCE 7 EQ 12.4-3) IBC 2018 1605.3.2 (ASCE 7 12.8.3) VERTICAL DISTRIBUTION (Per ASCE 7 - 12.8.3) Story Total Story Vert Dist Story Factored Story Area Height Height Weight Factor Force Force (ASD) Floor H hx Wx wxhxk CVX Fx Fx p/1.4 = EH/1.4 (ft�) (ft) (ft) (kips) (k-ft) (kips) (kips) Roof 670 11.00 11.00 15 162 1.00 1.9 1.4 Page of 29 Sum =1 162 1 1.000 1 1.9 1 1.4 Page 10 of 29 Project Number: Plan Name: Sheet Number: S220624-4 Folk Residence Addition L4 Engineer: Speci ics: Date: SB DESIGN LOADS 8/30/2022 FRONT / BACK APPLIED FORCES Wind Force 0.6 0o * Ws (kips) Seismic Force E/1.4 (kips) Per Level Sum Per Level Sum 1.06 1.38 1.06 1.38 1.06 1.38 Governing Force: ROOF 1.38 k Seismic 1st FLOOR Base Shear: 1.38 k Seismic 1 ■ SIDE / SIDE APPLIED FORCES I Wind Force 0.6 w * Ws (kips) Seismic Force E/1.4 (kips) Per Level Sum Per Level Sum 1.32 1.38 1.32 1.38 1.32 1.38 Governing Force: Z Roo` 1.38 k Seismic 1st FLOOR Base Shear: 1.38 k Seismic Page 10 of 29 Page 11 of 29 Project Number. S220624-4 I Plan Name: Folk Residence Addition Sheet Number. LS Engineer: ss Specifics: Shear walls Date: 0 3o zozz 2nd Story Walls (F)ront - Bask Direction) Smd Species HF All walls designed with Force-TronsPer should meet a minimum height to width ratio of2:1 at Pier (SDPWS 2018, Table 4.3.4) • Maximum allowed height to width mtio 3.5:1 for walls w/o openings (increased shear design values per SDPWS 2018, Table 4.3.4) ' Shear panel height is height to underside m mofm Boor flaming. "Adjusted" Story shear(kips) = 138 Govemtng Force (FB Direction) = Seismic Story height (ft)= 11.00 Dead load factor (FB Direction)= 0.90 BC 2018 Equation 16-22 Shear Ponel height (ft)= 10.00 00% story shear Total Diaphragm width(it)= 2025 YES load balance cheek=Wammg-Wall loads do not match story shear RED = Update Formula as requited- Important BLUE = Review and update w requited - Typical Input 2nd Story Walls (Front- Beck Dircetion) Hold downs and window straps HeightnNidth Force st Window Story Wall WeH Opening Opening Opening(max) Plate to Effective Trib. Width Percent Effective Story Sum Ponel Reduction(%) Design Panel Wall Roof Story Sum OTM RM Resultant HD HD/Strop to HD location Resultant Window Strap Mark L(ft) Width(ft) Height(ft) to Edge(ft) Opeting(ft) Leogth(ft) (ft) Sharing(%) Trib.Width V(kips) V(kips) Shear(plf) R=2eLB Shear(pit) Type Trib(ft) DL(klf) DL(Idf) (k-ft) (k-ft) HD(kips) TYPE DFmHF7 Edgednterim9 HD (Kips) 1 At 9.00 9.00 10.13 0.58 5.88 0.40 0.40 45 1.00 45 SW6 2.00 0.14 0.14 4A 7.4 -0.35 Brconc HF Edge No HD 0.00 No strap 1 A2 6.50 6.50 10.13 0.42 4.25 0.29 0.29 45 1.00 45 SW6 2.00 0.14 0.14 3.2 4.3 -0.19 Brconc HF Edge No HD 0.00 Nostrap 1 BA 9.50 9.50 10.13 1.00 10.13 0.69 0.69 73 1.00 73 SW6 7.00 0.24 0.24 7.6 13.9 -0.69 fir -cone HF Edge No HD 0.00 No strap 1 B.2 9.00 9.00 10.13 1.00 10.13 0.69 0.69 77 1.00 77 SW6 7.00 0.24 0.24 7.6 12.6 -0.59 fir -cone HF Ede No HD 0.00 strals S= 34.00 Total OSB wall length 25.00 S= 30.38 2.07 2.07 Warning- Total OSB Capacity 1.38 set)I (kips) Page 11 of 29 Page 12 of 29 Project Number: Plan Name: Sheet Number: 5220624-4 Folk Residence Addition L6 Engineer: Specifics: Date: Ss Shear walls S 30 2022 Notes: " All walls designed with Force-Transfr should meet a minimum height to width .fie of2:1 at Pier (SDPWS 2018, Table 4.3.4) • M-ftoum allowed height to width ratio 3.5:1 for walls w/o openings (increased shear RED = Update Formula as requhed-hnpottant design values per SDPWS 2018, Table 4.3.4) BLUE = Review and update as requhed-Typical Input " Shear panel height is height to underside or mofor floor fiaming. 2nd Story Walls(Side/ Side Direction) Stud Species HF 2nd Store Wall, (Side/ Side Direction) Hold downs and window straps "Adjusted" Story shear(Idps)= 1.38 Governing Force(F/B Direction) = Seismic Story height (ft)= 10.00 Dead load factor(F/B Direction)= 090 ®C 2018 Equation 16-22 Shear Panel height (ft)= 10.00 F 100% story shear Total Diaphragm width (it) = 44.00 YES load balance check = OK Height/Width Fmce at Window Story Wall Wall Opening Opening Opening (max) Plate to Effecfie Trib. Width Percent Effective Story Sum Panel Reduction(%) Design Panel Wall Roof Story Snm OTM RM Resultant HD/Strap to HD location HD Resultant Window Strap Mark Lift) Width (ft) Height (ft) to Edge (ft) Openmg(ft) Length(ff) (ft) Sharing(%) Trib.Width V(kips) VDdps) Shear(plf) R=2"I/fi Shear(plf) Type Trib(R) DL(klf) DL(klf) (k-ft) (k-ft) HD(kips) DFmHF? EdgeAmetim? TYPE HD (Kips) 1 1.1 14,50 14.50 22,00 1.00 22.00 0.69 0.69 48 1.00 48 SW6 2.00 0.14 0.14 6.9 13.2 -0.45 HF Edge Po-conc No RD 0.00 No strap 1 2.1 8,50 8.50 22.00 1.00 22.00 0.69 0.69 81 1.00 81 SW6 2.00 0.14 0.14 6.9 4.6 0.29 HF Edge 0r-cone, No RD 0.00 No strap S= 23.00 Totalosit-Hlength= 23.00 S= 44.00 1.38 138 OK Total OSB Capacity 138 (feet) (ltips) Page 12 of 29 Page 13 of 29 Project sheet number: Folk Residence Addition L7 Subject Date SHEAR WALL EQUATION DIAGRAM 813"12022 SHEAR WALL WITH WINDOW BASED ON SHEAR TRANSFER: WROOF Where: Vi = Story Shear VROOF Wi = Story Dead Load HDi = Story Holdown MOTi = Story Over Turning Moment i+l vi+1 panel MR; = Story Resisting Moment f ;di vi+1 plate MOT ROOF — VROOF X Ih+1 V1+1 W2 MR ROOF — 0.6 X WROOF X D2/2 Ha TT HDi+1 = (MOT ROOF - MR ROOF)/(D - 6") 1 w mn T Hi H Vi+1 panel = VROOF / (L, + I _) Vi panel Vi plate Vi+1 plate = VROOF / D Ho MOTi = 1(Vi+1 + VROOF) X Hil + MOT ROOF MR; = 0.6 x (Wi+1 + WROOF) x D2/2 HDi = (MOTi - MR1i)/(D - 6") Vi panel = (• ROOF + Vi+l) / (Li +,..) Vi plate = (VROOF + Vi+1) / D FORCE TRANSFER AROUND WINDOW CALCULATION (CANTILEVER PIER METHOD) Hs Vy Hw/2 Vi, Vh = Vi panel X I'— Vv = HDi V, Ti, = Vh (Hµ, / 2 + Ha) / Ha Tv = Is resisted by the continuous stud adjacent to the window. Page 13 of 29 Page 14 of 29 LONGITUDE ONE TWENTYO ENGINEERING & DESIGN FRAMING CALCULATIONS BEAM REFERENCE PER PLAN Existing to remain, typical unless noted otherwise it F O R T E Val E B M JOB SUMMARY REPORT S220624-4 - Folk Residence Paae 15 of 29 Ll qF Member Name Results Current Solution Comments 1B1 Passed 1 piece(s) 4 x 10 DF No.2 IjI Passed 1 piece(s) 2 x 10 DF No.2 @ 16" OC 1J2 (< 70% IS OK FOR PT) Passed 1 piece(s) 2 x 8 DF No.2 @ 16" OC 1B2 (<70% IS OK FOR PT) Passed 1 piece(s) 4 x 10 DF No.2 Roof Member Name Results Current Solution Comments R31 Passed 1 piece(s) 2 x 8 DF No.2 @ 16" OC R32 Passed 1 piece(s) 2 x 12 DF No.2 @ 24" OC RH1 Passed 1 piece(s) 4 x 6 DF No.2 RH2 Passed 1 piece(s) 4 x 6 DF No.2 RBl Passed 1 piece(s) 6 x 12 DF No.2 RH3 Passed 1 piece(s) 4 x 10 DF No.2 ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com A Weyerhaeuser 8/30/2022 11:37:44 PM UTC ForteWEB v3.4 File Name: S220624-4 - Folk Residence Page 15 of 29 Page 1 / 11 aFORTEWEB MEMBER REPORT LI, 1131 1 piece(s) 4 x 10 OF No.2 PASSED Page 16 of 29 Overall Length: 7' 3 1/4" 6i[-% C All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2583 @ 7' 3" 3828 (1.75") Passed (67%) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Shear (Ibs) 1754 @ 2' 4 3/4" 3885 Passed (45%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 3204 @ 4' 5 5/16" 4492 Passed (71%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.038 @ 4' 4 9/16" 0.192 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.057 @ 4' 4 13/16" 0.289 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total able Required Dead Floor Live Snow Factored 1 - Column - DF 3.50" �3.50" 1.91" 1516 2186 1366 4180 Blocking 2 - Column - DF 1.75" 5" 1.50" 904 1395/-91 843 2583 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T 3" o/c Bottom Edge (Lu) 7' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comm 0 - Self Weight (PLF) 0 to 7' 3 1/4" N/A 8.2 1 - Uniform (PSF) 0 to 7' 3 1/4" (Front) 12' 12.0 40.0 - Default Load 2 - Uniform (PSF) 0 to 7' 3 1/4" (Front) 12' 15.1 - 25.0 Snow System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC ForteWEB 0.4, Engine: V8.2.2.11122, Data: V8.1.2.2 Weyerhaeuser File Name: SpAffi -40fAk Residence Page 2 / 11 WFORTEWEB MEMBER REPORT L1, III 1 piece(s) 2 x 10 OF No.2 @ 16" OC PASSED Page 17 of 29 overall Length: 14 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 507 @ 1 1/2" 1406 (1.50") Passed (36%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 451 @ 10 3/4" 1665 Passed (27%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 1754 @ 7' 1/2" 2029 Passed (86%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.278 @ 7' 1/2" 0.346 Passed (L/598) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.382 @ T 1/2" 0.692 Passed (L/435) 1.0 D + 1.0 L (All Spans) TJ-ProT"' Rating N/A N/A N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Hanger on 9 1/4" HF IedgerOnMasonry 1.50" Hangers 1.50" 141 376 516 See note ' 2 - Beam - DF 3.50" 3.50" 1.50" 143 380 523 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) Continuous Bottom Edge (Lu) All Bearing Points System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LU28 1.50" N/A 8-10dx1.5 6-10dx1.5 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 14' 2" 16" 15.0 40.0 Default Load Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woc>dproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC ForteWEB 0.4, Engine: V8.2.2.11122, Data: V8.1.2.2 Weyerhaeuser File Name: SpAffi -40fAk Residence Page 3 / 11 2FORTEWEB" LI, 112 (< 70% IS OK FOR PT) 1 piece(s) 2 x 8 DF No.2 @ 16" OC PASSED Page 18 of 29 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 534 @ 1' 1 3/4" 3281 (3.50") Passed (16%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 344 @ 1' 10 3/4" 1305 Passed (26%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 840 @ 5' 3 5/16" 1360 Passed (62%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.108 @ 5' 3 1/8" 0.206 Passed (L/912) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.134 @ 5' 3 3/16" 0.411 Passed (L/736) 1.0 D + 1.0 L (Alt Spans) TJ-ProT"' Rating N/A N/A N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (2L/480) and TL (2L/240). • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on NDS. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Beam - DF 3.50" 3.50" 1.50" 107 427 534 Blocking 2 - Beam - DF 3.50" 3.50" 1.50" 85 346/-6 431 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) Continuous Bottom Edge (Lu) All Bearing Points Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 9' 7" 16" 15.0 60.0 Default Load System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC Data: V8.1.2.2 ForteWEB 0.4, Engine: VpZf2 Weyerhaeuser 48.2.2.11122, File Name: S P840-fAk Residence Page 4 / 11 2FORTEWEB" L1, 1132 (<700/o IS OK FOR PT) 1 piece(s) 4 x 10 DF No.2 PASSED Page 19 of 29 PF 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. C Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1754 @ 1/4" 2481 (1.75") Passed (71%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1297 @ 11" 3885 Passed (33%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 3051 @ 3' 6 1/4" 4492 Passed (68%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.061 @ 3' 6 1/4" 0.233 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.073 @ T 6 1/4" 0.350 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Stud wall - HF 1.75" 1.75" 1.50" 275 1479 1754 Blocking 2 - Stud wall - HF 1.75" 1.75" 1 1.50" 275 1479 1754 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 1" o/c Bottom Edge (Lu) 7' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads ' Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 7' 1/2" N/A 8.2 1 - Uniform (PSF) 0 to 7' 1/2" (Front) 7' 10.0 60.0 Default Load System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC ForteWEB 0.4, Engine: V8.2.2.122, Data: V8.1.2.2 Weyerhaeuser File Name: S pZ�1124940fAk Residence Page 5 / 11 2FORTEWEB" Roof, RJ 1 1 piece(s) 2 x 8 DF No.2 @ 16" OC PASSED Page 20 of 29 Sloped Length: 20 11 15/ 16' 4 ; 2' a All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 545 @ 2' 2 3/4" 5435 (5.50") Passed (10%) 1.0 D + 1.0 S (Adj Spans) Shear (Ibs) 380 @ 3' 3/8" 1501 Passed (25%) 1.15 1.0 D + 1.0 S (Adj Spans) Moment (Ft-Ibs) 1532 @ 9' 11 1/2" 1564 Passed (98%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.207 @ 0 0.235 Passed (2L/272) 1.0 D + 0.6 W (Alt Spans) Total Load Defl. (in) 0.949 @ 9' 11 1/2" 1.086 Passed (L/206) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Upward deflection on left and right cantilevers exceeds overhang deflection criteria. • Birdsmouth cut has not been analyzed. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Upward deflection on left and right cantilevers exceeds 0.4". • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Wind Factored 1 - Birdsmouth - DF 5.50" 5.50" 1.50" 210 335 -405 545/-117 Blocking 2 - Beveled Plate - DF 5.50" 5.50" 1 1.50" 210 335 -405 545/-117 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) Continuous Bottom Edge (Lu) All Bearing Points Vertical Load Location (Side) Spacing Dead (0.90) Snow (1.15) Wind (1.60) Comments 1 - Uniform (PSF) 0 to 19' 11" 16" 15.0 25.0 -30.0 Default Load Member Length : 21' 2 3/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 4/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC AForteWEB v3.4, Engine: V8.2.2.122, Data: V8.1.2.2 P 20 of 29 Weyerhaeuser File Name: SP2� -04 - Folk Residence Page 6 / 11 2FORTEWEB" Roof, RJ2 1 piece(s) 2 x 12 DF No.2 @ 24" OC PASSED Page 21 of 29 i 1' 6" All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. i 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 583 @ 16' 1/2" 2126 (3.50") Passed (27%) 1.0 D + 1.0 S (Alt Spans) Shear (Ibs) 488 @ 2' 10 3/4" 2329 Passed (21%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 2008 @ 8' 11 1/2" 3138 Passed (64%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.163 @ 8' 10 13/16" 0.477 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.259 @ 8' 10 15/16" 0.716 Passed (L/663) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on Nos. Supports ' Bearing Length Loads to Supports (Ibs) Accessories Available Required Dead Snow Factored 1 - Stud wall - HF 5.50" 5.50" 1.50" 270 449 719 Blocking 2 - Stud wall - HF 3.50" 3.50" 1.50" 218 366 583 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) Continuous Bottom Edge (Lu) All Bearing Points Vertical Load Location (Side) Spacing Dead (0.90) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 16' 3" 24" 15.0 25.0 Default Load System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC AForteWEB v3.4, Engine: VP8.2.2.2122, 2Data: V8.1.2.2 Weyerhaeuser File Name: S22�e24-40fF41k Residence Page 7 / 11 2FORTEWEB" Roof, RH 1 1 piece(s) 4 x 6 DF No.2 PASSED Page 22 of 29 PF 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. C Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1273 @ 0 3281 (1.50") Passed (39%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 990 @ 7" 2657 Passed (37%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1671 @ 2' 7 1/2" 1979 Passed (84%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.066 @ 2' 7 1/2" 0.175 Passed (L/954) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.107 @ 2' 7 1/2" 0.262 Passed (L/590) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - DF 1.50" 1.50" 1.50" 485 788 1273 None 2 - Trimmer - DF 1.50" 1.50" 1 1.50" 485 788 1273 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' 3" o/c Bottom Edge (Lu) 5' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 5' 3" N/A 4.9 1 - Uniform (PSF) 0 to 5' 3" 12' 15.0 25.0 Default Load System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC AForteWEB 0.4, Engine: Vp8.2.2.122, 22Daata: V8.1.2.2 Weyerhaeuser File Name: S P �40-fAk Residence Page 8 / 11 2FORTEWEB" Roof, RH2 1 piece(s) 4 x 6 DF No.2 PASSED Page 23 of 29 0 E All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. C Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1858 @ 2' 3" 6563 (3.00") Passed (28%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 895 @ 2' 10" 2657 Passed (34%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) -1071 @ 2' 3" 1979 Passed (54%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.043 @ 5' 8 3/16" 0.208 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 1 0.070 @ 5' 8 1/4" 0.313 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • -247 Ibs uplift at support located at 0". Strapping or other restraint may be required. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories T Available Required Dead Snow Factored 1 - Trimmer - DF 1.50" 1.50" 1.50" -60 44/-187 -247 None 2 - Trimmer - SPF 3.00" 3.00" 1.50" 717 1141 1858 None 3 - Trimmer - DF 1.50" 1.50" 1.50" 277 444 721 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 6" o/c Bottom Edge (Lu) 8' 6" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 6" N/A 4.9 -- 1 - Uniform (PSF) 0 to 8' 6" 7' 15.0 25.0 Default Load Notes System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com AForteWEB 8/30/2022 11:37:44 PM UTC 0.4, Engine: Vp8.2.2.122, V8.1.2.2 Weyerhaeuser 22Daata: File Name: S P2f2 340fAk Residence Page 9 / 11 2FORTEWEB" Roof, RB1 1 piece(s) 6 x 12 DF No.2 PASSED Page 24 of 29 17 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2990 @ 1' 8 3/4" 18906 (5.50") Passed (16%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1753 @ 2' 11" 8244 Passed (21%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 5462 @ 7' 1/8" 10166 Passed (54%) 1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in) 0.069 @ 6' 11 3/16" 0.518 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in) 0.115 @ 6' 11 5/16" 0.690 Passed (L/999+) 1.0 D + 1.0 S (Alt Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Overhang deflection criteria: LL (2L/240) and TL (2L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Column - DF 5.50" 5.50" 1.50" 1228 1763 2990 Blocking 2 - Column - DF 5.50" 5.50" 1.50" 934 1360 2294 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 12' 5" o/c Bottom Edge (Lu) 12' 5" o/c -Maximum allowable bracing intervals based on applied load. Dead Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.15) Comments 0 - Self Weight (PLF) 0 to 12' S" N/A 16.0 1 - Uniform (PSF) 0 to 12' S" (Front) 10' 15.8 25.0 Default Load System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC AForteWEB v3.4, Engine: V8.2.2.122, Data: V8.1.2.2 p 24 of 29 Weyerhaeuser File Name: SP2�P242-4 - Folk Residence Page 10 / 11 2FORTEWEB" Roof, RH3 1 piece(s) 4 x 10 DF No.2 PASSED Page 25 of 29 PF 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. C Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 2180 @ 0 3281 (1.50") Passed (66%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1707 @ 10 3/4" 4468 Passed (38%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 4497 @ 4' 1 1/2" 5166 Passed (87%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.090 @ 4' 1 1/2" 0.275 Passed (L/999+) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.149 @ 4' 1 1/2" 0.412 Passed (L/664) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - DF 1.50" 1.50" 1.50" 865 1315 2180 None 2 - Trimmer - DF 1.50" 1.50" 1 1.50" 865 1315 2180 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 3" o/c Bottom Edge (Lu) 8' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 3" N/A 8.2 1 - Uniform (PSF) 0 to 8' 3" 12' 9" 15.8 25.0 Default Load System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes 911111111111111111 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:37:44 PM UTC ForteWEB v3.4, Engine: V8.2.2.122, Data: V8.1.2.2 25 29 Weyerhaeuser File Name: Sp2aO%$ -4of - Folk Residence Page 11 / 11 2FORTEWEB' Roof, P1 - New deck roof column, typ 1 piece(s) 6 x 6 DF No.2 PASSED Page 26 of 29 Post Height: 13' Design Results Actual Allowed Result LDF Load: Combination Slenderness 28 50 Passed (57%) Compression (Ibs) 2991 12123 Passed (25%) 1.15 1.0 D + 1.0 S Base Bearing (Ibs) 2991 18906 Passed (16%) -- 1.0 D + 1.0 S Bending/Compression 0.21 1 Passed (21%) 1.15 1.0 D + 1.0 S • Input axial load eccentricity for this design is 16.67% of applicable member side dimension. • Applicable calculations are based on Nos. Supports Material Member Type : Free Standing Post Base Plate Douglas Fir -Larch Building Code : IBC 2018 Design Methodology : Aso Max Unbraced Length Comments Full Member Length No bracing assumed. 1 Drawing is Conceptual Vertical Load Dead (0.90) Snow (1.15) comments 1 - Point (lb) 1228 1763 Linked from: RB1, Support 1 Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Note: 1.23k + 1.76k = 3k 2 ft square footing adequate (allowable = 5500 lb. Braced at surface deck). ForteWEB Software Operator Job Notes Spencer Boyle L120 Engineering + Design (425) 636-3313 sboyle@1120engineering.com 8/30/2022 11:56:18 PM UTC AForteWEB 0.4, Engine: Vp8.2.2.122, 22Daata: V8.1.2.2 Weyerhaeuser File Name: S -40-fFolk Residence Page 1 / 1 Page 27 of 29 - LONGITUDE ONE TWENTYO ENGINEERING & DESIGN FOUNDATION CALCULATIONS FOOTING REFERENCE PER PLAN Project: Foundation calculations - 1500 psf Location: 16" continous footing (max loading) - bearing Footing [2015 International Building Code(2015 NDS)] Footing Size: 16.0 IN Wide x 8.0 IN Deep Continuous Footing With 8.0 IN Thick x 18.0 IN Tall Stemwall Long itudinalReinforcement: (2) Continuous #4 Bars TransverseReinforcement: #4 Bars @ 12.00 IN. O.C. (unnecessary) Section Footing Design Adequate FOOTING PROPERTIES Allowable Soil Bearing Pressure: Qs = 1500 psf Concrete Compressive Strength: F'c = 2500 psi Reinforcing Steel Yield Strength: Fy = 40000 psi Concrete Reinforcement Cover: c = 3 in FOOTING SIZE Width: W = 16 in Depth: Depth = 8 in Effective Depth to Top Layer of Steel: d = 4.25 in STEMWALL SIZE Stemwall Width: 8 in Stemwall Height: 18 in Stemwall Weight: 150 pcf FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Effective Allowable Soil Bearing Pressure: Width Required: Beam Shear Calculations (One Way Shear): Beam Shear: Allowable Beam Shear: Transverse Direction: Bending Calculations: Factored Moment: Nominal Moment Strength: Reinforcement Calculations: Concrete Compressive Block Depth: Steel Required Based on Moment: Min. Code Req'd Reinf. Shrink./Temp Controlling Reinforcing Steel: Selected Reinforcement: Reinforcement Area Provided: Development Length Calculations: Development Length Required: Development Length Supplied: Longitudinal Direction: Reinforcement Calculations: Min. Code Req'd Reinf. Shrink./Temp Controlling Reinforcing Steel: Selected Reinforcement: Reinforcement Area Provided: Qu = 1388 psf Qe = 1400 psf Wreq = 1.32 ft Vu1 = 0 lb Vc1 = 3825 lb Mu = 1310 in -lb Mn = 0 in -lb a = 0.30 in As(1) = 0.01 in2 (AC I-10.5.4)As(2) = 0.19 in2 As-reqd = 0.19 in2 Trans: #4's @ 12.0 in. o.c. As = 0.19 in2 Ld = 15 in Ld-sup = 1 in (ACI-10.5.4): As(2) = 0.26 in2 As-regd = 0.26 in2 Longitudinal: (2) Cont. #4 Bars As = 0.39 in2 StruCalc 9.0 Page 28 of 29 page S�truCal"l, _ - StruCalc Version 10.0.1.6 12/16/2017 1:04:55 PM LOADING DIAGRAM 8 in 8 in P T 3 in 1 1.333333 ft Live Load: PL = 1000 plf Dead Load: PD = 700 plf Total Load: PT = 1850 plf Ultimate Factored Load: Pu = A0 Dlf MAXIMUM 1.85 KLF ALLOWABLE Page 28 of 29 Project: Foundation calculations - 1500 psf Location: 2x2 SO ftg (max loading) - bearing Footing [2015 International Building Code(2015 NDS)] Footing Size: 2.0 FT x 2.0 FT x 10.00 IN Reinforcement: #4 Bars @ 8.00 IN. O.C. E/W / (3) min. Section Footing Design Adequate FOOTING PROPERTIES Allowable Soil Bearing Pressure: Qs = 1500 psf Concrete Compressive Strength: F'c = 2500 psi Reinforcing Steel Yield Strength: Fy = 40000 psi Concrete Reinforcement Cover: c = 3 in FOOTING SIZE Width: W = 2 ft Length: L = 2 ft Depth: Depth = 10 in Effective Depth to Top Layer of Steel: d = 6.25 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m = 3.5 in Column Depth: n = 3.5 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu = 1375 psf Effective Allowable Soil Bearing Pressure: Qe = 1375 psf Required Footing Area: Areq = 4 sf Area Provided: A = 4.00 sf Baseplate Bearing: Bearing Required: Bear = 8000 lb Allowable Bearing: Bear -A = 33841 lb Beam Shear Calculations (One Way Shear): Beam Shear: Vu1 = 1917 lb Allowable Beam Shear: Vc1 = 11250 lb Punching Shear Calculations (Two Way Shear): Critical Perimeter: Bo = 39 in Punching Shear: Vu2 = 6680 lb Allowable Punching Shear (ACI 11-35): vc2-a = 54844 lb Allowable Punching Shear (ACI 11-36): vc2-b = 76875 lb Allowable Punching Shear (ACI 11-37): vc2-c = 36563 lb Controlling Allowable Punching Shear: vc2 = 36563 lb Bending Calculations: Factored Moment: Mu = 24000 in -lb Nominal Moment Strength: Mn = 127575 in -lb Reinforcement Calculations: Concrete Compressive Block Depth: a = 0.46 in Steel Required Based on Moment: As(1) = 0.11 in2 Min. Code Req'd Reinf. Shrink./Temp. (ACI-10.5.4): As(2) = 0.48 in2 Controlling Reinforcing Steel: As-reqd = 0.48 in2 Selected Reinforcement: #4's @ 8.0 in. o.c. e/w (3) Min. Reinforcement Area Provided: As = 0.59 in2 Development Length Calculations: Development Length Required: Ld = 15 in Development Length Supplied: Ld-sup = 9 in Note: Plain concrete adequate for bending, therefore adequate development length not required. StruCalc 9.0 Page 29 of 29 page S�raCal"C _ StruCalc Version 10.0.1.6 12/16/2017 1:04:56 PM LOADING DIAGRAM 3.5 in 10 in I n � T 3 in 2 ft FOOTING LOADING Live Load: PL = 3500 lb Dead Load: PD = 2000 lb Total Load: PT = 5500 lb Ultimate Factored Load: Pu =4JO0 lb Footing plus soil above footing weight: Wt h22 lb MAXIMUM 5.5k ALLOWABLE Page 29 of 29