Loading...
BLD20190745 (2)0� ED Af �Ip ITY OF EDMONDS 121 5TH A VENTUE NORTH - EDM ONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 C. lr'V4 STATUS: ISSUEUAWT-0-15019 Permit#: BLD20190745 BUILDING PERMIT Expiration Date: 06/19/2020 Project Address: 8129 LAKE BALLINGER WAY SW,' 7�1-10t( EDMONDS Parcel No: 00491100001506 FIRST WESTERN DEVELOPMENT GUARDIAN SECURITY SYSTEMS INC GUARDIAN SECURITY SYSTEMS INC C/O A SSOCI AT F S LLC SHDP CIO FRANK CLOSE C/O FRANK CLOSE 13S9 NORTH 205TH ST STE B 1743 1 ST AVE S 1743 1 ST AVE S SEATTLE, WA 98133 SEATTLE, WA 98134 SEATTLE, WA 98134 (425) 558-4030 (206) 622-6545 (206) 622-6545 LICENSE#: GUARDSIS233K5 EXP:09/30/2020 JOB DESCRIPTION ADDING 4 DEVICES TO TI VALUATION: $0 PERMIT TYPE: Commercial PERMIT GROUP: 79 - Fire Alarm GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD FENCE: 0 X 0 FT.) CODE: IOTHER: ------- OTHER DESC: IZONE: INUMBER OF STORIES: 0 IVESTED DATE: INUMBER OF DWELLING UNITS: 0 11 nT 41- UXISTING ARE -A I ST FLOOR: 0 2ND FLOOR: 0 PROPOSI]DAREA �79ASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS: 0 BATHROOMS: 0 IBEDROOMS: 0 BATHROOMS: 0 FRONT SETBACK SIDESETBACK REARSE­['BACK REQUIRED: PROPOSED� J`RUIRED: PROPOSED: IREQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Print Released By Date ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CER71FICATE OF OCCUPANCY HAS BEEN GRANfED. UBCI09/ IBC I I0/IRC1 10, FIRE APPLICANT = ASSESSOR CTIFY STATUS: ISSUED BLD20190745 CONDITIONS • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • SoundNoise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Cbapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00arn and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to inderrinify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, aris ing directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. INSPECTIONS THIS PERMI`TAUTHORIZ_ES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMrT: SEE ECDC 19.00.005(A)(6) BUILDING ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you FIRE (425) 775-7720 3. Then: Perm its/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand comer) (425) 771-0220 RECYCLING (425) 275-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Alarm System Acceptance • F-Fire Compliance • F-Fire Final BUILDING PERMIT APPLICATION Development Services Building Division 121 5th Ave N / Edmonds, WA 98020 425.771.0220 For handouts, submittal requi rem ents, permit status and inspection scheduling information go to: htti3://www.edmondswa.poy/ JOB SITE INFORMATION/LCICATION: (Where the work is taking place) Job Site Add ress:U29 ��.BaLaAul Aw Pa rce 1: CIDCI�) Lot /Unit/Su ite #: Subdivision: PROPERTY OWNER: Name: E_amooc��_' (kA Mailing Address:PC) 'b_Ek � (a City/State/Zip:\f�a—'��\� A- q (ME 2) Phone #: Email: �M�"a k VT�_T .- Ly'\ OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? 0 Yes 0 No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT/ CONTACT INFORMATION: Name of Applicant: MailingAddress: City/State/Zip: CC, Phone#: E-mail: GENERAL CONTRACTOR: (If different from applicant) General Contractor: CivayiWLAgLA �-Vu'�wl Mailing Address: nq�) VJ�- Ave-, -t) \' j City/State/Zip: 'SMA�U4 Phone #: E-mail: L1YAA_D_DK WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: CITY OF EDMONDS BUSINESS LICENSEM Oflice Use Only TYPE OF PERMIT (Provide • Accessory Structure/ Detached Garage Details on Page 2) 0 Addition • Demolition El Mechanical • New Single Family / Duplex 0 Plumbing • Fire Sprinkler 0 Remodel • New Commercial/ Mixed Use 0 Re -Roof • Signs 0 Tank 1ATenant Improvement V 0 Other Remodel Permff fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: v) — I PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement scl ft: Finished 0 Unfinished 0 Ist Floor, scl ft: 2nd Floor, sci ft: Garage/Carport:, sci ft: Deck/Covered Porch/Patio: Other scl ft: PROJECT DESCRIPTION W �� /A VYA k-� W 0\1 CN Z')�w "A-:� miA on C, I certify that the Information I have provided on this form/application Is true, correct and complete, and that I am the property owner or duly authori2ed agent ofthe property ownerto submit a permit application totheCityof Edmonds. Print Name A-)efta e:�_Um lci uu� a Signature. I A DateRbA GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes El No El WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec Other Qty A/C Unit /Compressor Air Handler /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions If a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty QtY Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Toilets Other: GAS/FUIEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs City A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) QtY QtY Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air I Other: I I Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y/N 1 PSCAA Case #: Critical Areas Determination: Study Required 11 Conditional Waiver 11 Waiver 0 ,3,uuy il 7 0 Fill Material: F I in Place - — ----- , Removal 0 Sie of Tank Critical Areas Determination: L StudyRequiredL] Conditional Waiver Ll Waiver0 GRADE/FILL/EXCAVATE Grading: Cut_ cubic yards Fill cubic yards Cut / Fill In Critical Area: Yes El No 11 GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years, LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. j, 6% It _� SYSTEM SENSOR Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150. and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings —Inv SIGNALING LISTED S5512 FM approved enept ;�25-�653:05N S40 1 1 for ALERT odels 35- 65105M 3057383 RECEIVED JUN 19 204 BUILDING I& LD cawx C) #a/%. LIW S AVDS868-02 - 12101/20 17 - Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-Inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/'B-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync*CircuitTM Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync*Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model - listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply Synchronization Module The module shall be a System Sensor SynceCircult model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11A6 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32-F to 120-F (O-C to 49-C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate I flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 2 8 to 17.5 V (112 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8"diameter x 2.5"high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs, 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. , AVDS868-02 - I?JOI/2017 - Page 2 V-4 0 A. UL Current Draw Data 8-1Z5V0lts 16-33VOlts 8-IZ5Volts 16-33Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 Range 30 87 153 41 63 60 86 Temporal Temporal High LOW 39 28 44 32 54 .54 75 N/A ill 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal LOW 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Coded 3.1 KHz Coded Low High High 28 43 42 29 47 43 54 54 54 UL Max. Current Draw (rnA DC Input RMS), Ceiling 8-1 Z5 Volts 15cd Horn Strobe, 30cd Candela 16-33 Volts 15cd Range 30cd (15-177 cd) 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High ill 164 69 94 147 163 184 229 257 3. 1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non -Temporal High ill 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe output (d-B-A-) 8-1Z5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 - 12/01/2017 - Page 3 4h L-Series Dimensions u— � (173 n 2.47' (62.7 mil 1.37' (34.8 mm) A0545-00 Ceiling -Mount Horn Strobes 01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Hom Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 6 92'H­ (11 75, Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Ceiling Strobes SCRIL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories 2.5' (64 thm) C A0546 CC -01 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White WD 7 System Sensor. SYSTEM 3825 Ohio Avenue * St, Charles, IL 60174 Product specitications subject tolchange vAthout notice. Visit systemsersorcom Phone: 800-SENSOR2 * Fax: 630-377-6495 for current product information Including the latest version of this data sheet, SENSOR' AVDS��02 - 12401/2017 .e IF 5 YY FEM 4 Indoor Selectable - Output Horns, Stirobes, and Horn Strobes for Waig Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modem aesthetics. Features 11111 lot • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING LISTED S5512 FM approved except 7125-1653t5N S4011 for ALERT models 7135-1620M 3057383.3057072 I AX The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections, AVOS865-05 - 2t2212018 - Pagp I L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box, A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SyncoCircuif' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncoCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model - listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon f lash tube and associated lens/reflector system. Ham Strobe Combination The horn strobe shall be a System Sensor L-Series Model - listed to UIL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync*Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/s-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32oF to 120oF (OoC to 49oC) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range? 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDU Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x: 1.91 -D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91 " D (1133 mm L x 88 mm W x 49 mm D) Ham Dimensions 5.6-L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Ham Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-M - 2=018 - Page 2 A UL Current Draw Data Candela 8-175 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Horn Current Draw (rnA RMS) 8-175 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal LOW 28 32 54 Non -Temporal High 43 47 54 Non -Temporal LOW 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal LOW 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 UL Max. Current Draw (mA DC Input RMS), Wall Horn 8-1Z5VbIts 15cd Strobe, 30cd Candela Range 16-33 Volts 15cd (15-185 30cd cd) 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 ill 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Ternportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 Ill Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High ill 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 288 3. 1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3. 1 K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Morn anb-Aorn Switch Position Strobe &UtpUt (C16A) Sound Pattern dB 8-1Z5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal LOW 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9� Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant. the horn output remains constantly on. AVOS865-05 - 2/22/2018 - Page 3 14 L-Series Dimensions 1.91" 1W 1.46" 46.5 rhm 1.25' 3.57— IM" 1.25" 32 mm (9.1 cm) (3.9 cm) K7.i 32 mm ­ 111A_ up 5.27' 5 C 13Z9 — 5.27" (13.738c'm) 133.9 min 0— so A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBi SBBGWL 4.7W (11.94 cm) 47" (4.85 cm) 1.25' Ur 185* 1.25' 119mm 32 mm (12.24cm) (4.69 cri (3.18ri UP 5.67" 5.67" 5.78' 1 C (14.4cm) 144�fmm 14M=) 0 — A0550-00 A0549 DD A 554-01 Strobe, Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 f ils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WIL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWIL Strobe, White SGRIL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL_P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horl HRL* Horn, Red HWL* Horn, White HGRL* Compact Horn, Red HGWL* Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWl_ Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SIP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. *Horn -only models are listed for wall or ceiling use. "m TEA4 3825 Ohio Avenue a St. Charles, IL 60174 OW18 System Sensor. Phone: 800-SENSOR2 a Fax: 630-377-6495 Product specifications subject to change Without notice. Visit systemsensorcom 4 for current product information. Including the latest version of this data sheet. SENSOff www.systemsensor.com AVDS865-05 - 2/22/2018 FIRST WESTERN = SUffE 104 EDMONDS OFF�CE BLDG, TA, SHEET # DESCRIPTION FA-01 SYSTEM INFORMATION FA-02 CALCULATIONS & TYPICAL WIRING AND MOUNTING DETAILS FA-03 MAIN FLOOR & MEZZANINE FIRE ALARM PLANS SHEET LIST ADDITION OF 4 NEW NAC DEVICES & RELOCATION OF 1 EXISTING NAC DEVICE DUE TO THIS TENANT IMPROVEMENT 2 WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE S STROBE CIRCUIT TWO #14 FPLP I INITIATION CIRCUIT TWO #16 FPLP CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. MAXIMUM FILL CONDUIT SIZE .12 SQUARE INCH .21 SQUARE INCH 1/2" .34 SQUARE INCH 3/4" .60 SQUARE INCH 1.1 .82 SQUARE INCH 1-1/4" 1.34 SQUARE INCH 1 -1 2" 2 HRE ALARM SYSTEM EDMONDS, WASHNGTON 1, ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80' TO BOTTOM. NFPA 72, 2013 EDITION, ALLOWS 80-96' FOR VISUAL DEVICES (CH. 4-4.4) AND REQUIRES A MINIMUM OF 90' TO TOP FOR AUDIBLE DEVICES OR 6' FROM CEILING , WHICHEVER Is LOWER (CH. 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR> VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24 , FROM CEILING TO TOP OF LENS FOR 110cd (CH. 4-4.4.3.2) 2. ALL EQUIPMENT SHALL BE U.L. LISTED, 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC, 4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545), FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5, DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 7. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM.TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED 'CONDUITS SHALL BE FURNISHED AND INSTALLED 33Y ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION, SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL 13E INSTALLED 13Y ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 8. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 9. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL , ALL INITIATING AND INDICATING DEVICE CIRCUITS. 10, ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES, ALL SPLICED WIRE PDSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15clB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS, 13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED <UUJS), 14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL C13NTRACTOR PER NEC AND AHJ 16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 17. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS 18, A SET OF AS BUILT DRAWINGS TO BE TURNED INTO GSSINC WITH APPROPRIATE COLOR CODED MARKUP DRAWINGS (SEE SYMBOL LEGEND FOR COLOR CODING). QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT E FFACPIE FIRE ALARM CONTROL PANEL D7024 BOSCH EXISTING 66" A.F.F. (EXISTING) TO TOP E �E RF COMMUNICATOR 7788F AES EXISTING 66" A.F.F. (EXISTING) TO TOP E F-F—M-] FIRE ALARM ANNUNCIATOR D7036 BOSCH EXISTING 60" A.F.F. E (EXISTING) TO TOP 2 FIRE ALARM HORN STROBE PC2WL SYSTEM SENSOR 4S BOX CEILING (NEW) FIRE ALARM STROBE SCWL SYSTEM SENSOR 4S BOX CEILING (NEW) 1 8 FIRE ALARM HORN STROBE P2WL SYSTEM SENSOR 4S BOX 80" A.F.F. (NEW) TO BOTTOM E (1) FIRE ALARM HORN STROBE PC2W SYSTEM SENSOR 4S BOX CEILING (EXISTI N G- RELOCATED) E FIRE ALARM HORN STROBE PC2W SYSTEM SENSOR EXISTING CEILING (EXISTING) E FIRE ALARM STROBE SWL SYSTEM SENSOR EXISTING 80" A.F.F. _):SCE (EXISTING) TO BOTTOM E 13E SMOKE DETECTOR EXISTING BOSCH EXISTING CEILING (EXISTING) E BE MANUAL PULL STATION EXISTING' -FIRELITE EXISTING 48" A.F.F. (EXISTING) TO CENTER -NWV- END -OF -LINE VERIFY LOCATION - - - RESISTOR IN FIELD EXISTING N/A N/A N/A N/A E DEVICE R EX STING DEVICE N/A N/A N/A N/A REOCATED --- A.F.F. ABOVE FINISHED N/A N/A N/A N/A FLOOR --- F.B.O. FURNISHED BY N/A N/A N/A N/A OTHERS --- N/A NOT N/A N/A N/A N/A APPLICABLE --- RED AS BUILT N/A N/A N/A ADD OR CHANGE --- GREEN AS BUILT N/A N/A N/A REMOVE --- BLUE AS BUILT N/A N/A N/A NOTES TO CAD CITY OF EDMONDS BU EPARTMENT WORK APPROVED DATE: PERMIT NUMBER eLL Z�cl 9- 0--) q,,�- Rec 27 63 (0010 clill /STE L EXPIRES 09/01/2020 x Ld Lu sirej 0 0 Lij 0 ��9 2 U- P a LL —00 cc 0 -�E -z Lu >10 U) <F- C) U>) �: Q 0 Z u) Erz 2i W 2: LL 0 Ir 010 z < _j r) -JC6 U_1 < Lu Erma I-L Uj oz z am M w w co cl) w Lli cl) LL [SCALE: NOT TO SCALE ) DATE: 06/17/19 BACKROUND PLAN PROVIDED L JOB NUMBER: 45343-1 WIRE DESIGNATION GENERAL NOTES SYMBOLS LEGEND FA-01 Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved FACP ADD ON VOLTAGE DROP & LOAD CURRENT CALCULATION FOR EXISTING NAC CIRCUIT S1 NOTE: EXISTING NAC CIRCUIT S1 LENGTH WAS ASSUMED TO BE 400 FEET BECAUSE MOST THE WIRES ARE EXISTING. ONLY NAC CIRCUIT S1 WAS SHOWN BECAUSE THERE IS NO INFORMATION FOR THE OTHER NAC LOAD. S G TO EXISTIN EOL BOSCH D7024 PANEL HORN STROBE H.R STROBE STROBE STROBE TYPICAL NAC CIRCUIT WIRING DETAIL BOSCH D7024 Notification Appliance Circuit Detail PR'6JECT: FIRST WESTER'k--'-'SUITE 10'4'E-D--'M"OND'S"'OFFlCE BLDG TI Panel: EXISTING BOSCH D7024 CONTROL PANEL Wire Resistance 2.58 NEW 1 PC2WL @15cd 54 54 NEW 1 PC2WL @30ccl 71 71 NEW 1 P2WL @30cd 65 65 NEW I SCWL @15cd 41 41 EX 1 PC2W @75cd 157 157 EX 1 PC2W @95cd 182 182 N EX 5 SW @15cd 66 330 DEVICES 11 TOTAL mA= 900 14 400 22.14 900 Total Wire Resistance ( R) ( WIL � 2 ) - (R/ft) 2. Total Device Load, Amps (1) (Total Cct Load) 0. Voltage Drop E) (E= I * R) 11� EOL Voltage 24 - E) CALCULATIONS HARD L CEILING //— 4S BOX I� rj 0 0 CEILING STROBE HORN STROBE/STROBE MOUNTING DETAIL (DROP CEILING) TYPICAL WIRING AND MOUNTING DETAILS � 00 0 0 �Ico �OO — 4S BOX CEILING STROBE HORN STROBE/STROBE MOUNTING DETAIL (HARD LID) c-, >< CLHU 0 Z ' �01 < Ed FIRST WESTERN SUITE 104 T.I. NAC DEVICES j OR HORN STROBE & STROBE BOX MOUNTING DETAIL V E,> WkSINY, 2 RECEIVED GISTe ONA JUN 19 2019 EXPIRES 09/01/2020 BUILDING 14 by Guardian Securilty Systems. Inc. All III - (-5 � LL LU LL F- 0 20 w F- 0 ED z �; cc 2 LU 0 jr 0 Z < w < w tr M I a: w z w C/) w 3: F- C/) Cc LL OR U) 7;1 0 C) C) SCALE: NOT TO SCALE DRAWN BY: D. GARCIA DESIGNED BY: T. QUAALE DATE:06/17/19 BACKROUND PLAN PROVIDED I ,JOB NUMBER:45343-1 SHEET FA-02 FLAG NOTE: RELOCATE EXISTING DEVICE TO NEW SPECIFIED LOCATION. MAINTAIN CIRCUIT CONTINUITY. MAIN FLOOR FIRE ALARM PLAN SCALE: 1/81, = 1 101, \-. V Ez �> 27 63 L EXPIRES 09/01/2020 LAW S (D MEZZANINE FIRE ALARM PLAN SCALE: 1 /811 = i loll 0i G� I L KEY PLAN Recelvep SCALE: NOT TO SCALE ptj is 20 qUILDING Copyright 2014 by Guardian Security Systems, Inc. All Riqhts Reserved 10 C, >< LU 3: LL Ld L, J� LU F-- C> '0 Lu CIO — OFA m1w (L d w (.) 0 < LL w LL 0 2 (/)z LL C/) �'- ��R w 0 1>0- 3: z Z C/) CC 0 CTS z > C, --� N LU <CQ LLj cc aa N wz w YO CDW Cz LU C1J cc: 0 w 0 F— U- C/) z CC LL SCALE: 1/8"=I'O" JOB NUMBER:45343-1 —SHEET FA-03