BLD201900530� E1)'v
/I
0-
CITY OF EDMONDS
64Ai
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
ne. 1
STATUS: ISSUED 01/17/2019
Expiration Date: 07/17/2020
Parcel No: 00434202300100
__ __ __ ___ ___ -1
Pennit#: BLD20190053,
-Project Address: 250 5'I'H AVE N, EDMONDS,
ruvw1w. ",1_0111111
CITY OF EDMONDS PERFORMANCE SYSTEMS INTEGR LLC PERFORMANCE SYSTEMS INTEGR LLC
C/O CITY OF EDMONDS CIO CLINTON PETERSON C/O CLINTON PETERSON
2SO 5TH AVENUE N 193 10 NORTH CREEK PRKWY ST 109 193 10 NORTH CREEK PRKWY ST 109
EDMONDS, WA 98020 BOTHELL, WA 98011 BOTHELL, WA 98011
(503) 641-2222 (503) 641-2222
LI CENSE #: PERFOST 8 3 1 P E EXP: 10/05/2019
rNSTA LLA T1 ON OF I NEW I OA M P BOOSTER POW
VALUATION: $0
,PLY FOR EXI STING FIRE A LA RM SYSTEM
PERMIT TYPE: Commercial
PEgMft GROUP: 79 - Firc Alarm
GRADING: N CYDS: 0
TYOI)�QF CONSTRUCTION:
RETAINING WALL ROCKERY: '4QQCCUPANT
GROUP:
Ot-QUPANT LOAD:
FENCE: 0 X 0 FT.)
CODE:
OTHER: ------- OTHER DESC:
N �
INUMBER OF STORIES: 0
ST ED DATE:
INUMBER OF DWELLING UNITS: 0
ILOT #-
EXISTING AREA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
PROPOSI-1) AREA
TA77M—=N : 0 1 ST FLOOR: 0 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
BEDROOMS: 0 BATHROOMS: 0
BEDROOMS: 0 BATHROOMS: 0
FRONTSETBACK SIDESEIFBACK REARSEIFBACK
REQUIRED: PROPOSED: 7QUIRED: PROPOSED: IREQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED:
SETBACK NOTES:
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, N—O
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION
INSURANCE AND RCW 18:27.
THIS APR-ICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
"Signature Print Name Date Released By// Date
ATTENTION
ITIS UNLAWFULTO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPEC11ON HASBEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/IRCI 10.
= FIRE = APPLICANT = ASSESSOR = Cny
STATUS: ISSUED
BLD20190053
• Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from ternporary construction s ites as a result of construction activity are exempt from the noise Emits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatevernature, arising directly or indirectly from the issuance for this pen -nit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHIOREES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDIDNALKS, DRr\/EVVAYS, MARQUEES, ETC.) V\ALL REQUIRE SEPARATE PERMISSION. PERMIT
TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING
ENGINEERING (425) 771-0220 EXT. 1326
1. Go to: w\Aw.edmondswa.gov
Building Department Inspections
2. Then: Servces
are now scheduled online. If you
FIRE (425) 775-7720
3. Then: Permits/Development
have difficulties, please call the
4. Then: Online Permit Info
Building Department front desk for
PUBLIC WORKS (425) 771-0235
5: If you don't have one already, create a
assistance during office hours.
login (upper right hand corner)
(425) 771-0220
RECYCLING (425) 276-4801
_6: Schedule your inspection .
I
I I
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon.
0 F-Fire Alarm System Acceptance
X1
.". j b,
BUILDING PERMIT
APPLICATION
Development Services
Building Division
121 5th Ave N / Edmonds, WA 98020
425.771.0220
For handouts, submittal requirements, permit status and inspection
scheduling information go to: htto://www.edmondswa.ito
JOB SITE INFORMATION/LOCATION: (Where the work is taking place)
Job Site Address: 250 5th Ave, N. Edmonds
Parcel:
Lot /Unit/Suite #: Subdivision:
PROPERTY OWNER:
Name: City of Edmonds
Mailing Address:
City/State/Zip:
Phone #:
Email:
OWNER INSTALLATION: *If yes, read and sign*
Will work be performed by the property owner? El Yes U No
I own, reside in, or will reside in the completed structure.
This installation is being madeon property that I own which is
not intended for sale, lease, rent, or exchange according to
RCW 18.27.090.
Owner Signature:,
APPLICANT / CONTACT INFORMATION:
Name of Applicant: Carissa Thomson
Mailing Address: 19310 N. Creek Pkwy #109
City/State/Zip: Bothell, Wa 98011
Phone #: 42S-368-4201
E-mail: cari s sa@ps integrated. com
GENERAL CONTRACTOR: (if different from applicant)
General Contractor: Same
Mailing Address:
City/State/Zip:
Phone #:
E-mail:
WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE:
PERFOSI831PE
CITY OF EDMONDS BUSINESS LICII NR-024445
Office Use Only
TYPE 0 F PERMIT (Provide
• Accessory Structure/
Detached Garage
Details on Page 2)
0 Addition
• Demolition
0 Mechanical
• New Single Family / Duplex
0 Plumbing
El Fire Sprinkler
0 Remodel
0 New Commercial/ Mixed Use
0 Re -Roof
13 Signs
0 Tank
0 Ten ant Improvement
N Other Fire Alarm
Remodel Permit fees are based on:
The value of the work performed, Indicate the value (rounded to
the nearest dollar) of all equipment, materials, labor, overhead,
and the profit for the work indicated on this application.
Valuation: �4, 671 . 30
PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION
Basement sq ft: Finished C] Unfinished 0
1st Floor, sq ft:
2nd Floor, sq ft:
Garage/Carport:, sq ft:
Deck/Covered Porch/Patio:
Other sq ft:
PROJECT DESCRIPTION
Installation of (1) new 10amp
boost.er power supply for existing
fire alarm system,
I certify that the information I have provided on this form/application is true,
correct and complete, and that I am the property owner or duly authorized
agent of the property owner to submit a permit application to the City of
Edmonds.
Carissa Thomson
Print Name:
Signature: Date 1/17/19
Fire Alarm
Submittal Guide
Edmonds Public Safety Building
2505 1h Ave. N. Edmonds, WA 98020
Scope of work:
Installation of (1) new 10amp b
fire alarm system.
Prepared By:
BUILDING DEPARTMENT
WORK r-fltle.
ADDRESS
OWNER —77711 xr-p
APPROVED DATE: L7ZI I
BLDG. OFFICIAL: /
------- ----- i
North Creek Pkwy #109
PERFORMANCE cITY corel, WA 98011
SYSTEMS INTEGRAT11ON Phone: 425-368-4201
Fax: 425-368-4208
E-N-1-- NII- CE-fl-.. 1/16/2019 RECEIVED
JAN 117 2019
BUILDING
Fire Alarm
Project Material List
Edmonds Public Safety Building
2505thAve. N. Edmonds, WA 98020
Part Number Description
BPS10A BOOSTER POWER SUPPLY
12V8AH BATTERIES
51GA-CC1S SYNC MODULE
I 'T ffi Ra 6 Po 0 h ' "HE " � awmi A N � C E
SYS41EMS INTEGRATION
�*I WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
19310 North Creek Pkwy #109
Bothell, WA 98011
Phone: 425-368-4201
Fax: 425-368-4208 RECEOVED
2/16/19 JAN 17 2019
BUILDING
E—DWIARDS Catalog C> Power Supplies and Accessories
FE-1) Wffv/ n_L Iq
LIFE SAFETY �_ INCIDENT MANAGEMENT
Remote Booster
Power Supnlies
BPS6A,BPS10A
Overview
The Booster Power Supply (BPS) is a UL 864, 9th Edition listed
power supply. It is a 24 Vdc filtered -regulated, and supervised
unit that can easily be configured to provide additional notification
appliance circuits (NACs) or auxiliary power for Mass Notification/
Emergency Communication (MNEC), as well as life safety, security,
and access control applications.
The BPS contains the circuitry to monitor and charge internal
or external batteries. Its steel enclosure has room for up to two
10 ampere -hour batteries. For access control -only applications,
the BPS can support batteries totaling up to 65 ampere -hours in
an external enclosure. The BPS has four Class B (convertible to
two Class A) NACs. These can be activated in one or two groups
from the BPSs unique dual input circuits.
The BPS is available in 6.5 or 10 ampere models, Each output
circuit has a capacity of three amperes; total current draw cannot
exceed the unit's rating.
The BPS meets current UL requirements and is listed under the
following standards:
Standard (CCN)
Description
UL864 9th ed.ftion (UO)NFire Alarm Systems
UL636 (ANET, UEHX7)
Holdup Alarm Units and Systems
UL609 (AOTX. AOTX7)
Local Burglar Alarm Units and Systems
UL294 (AILVY. UEHX7)
Access Control Systems
UL365 (APAW, APAW7)
Police Station Connected Burglar Alarm Units and Systems
UL1 076 (APOU, AP01,17)
Proprietary Burglar Alarm System Units
ULl 610 (AMCX)
Central Station Alarm Unit
ULC-S527 (UOXXC)
Control Units, Fire Alarm (Canada)
UILC-S303 (AOTX7)
Local Burglar Alarm Units and Systems (Canada)
C22.2 No. 205
Signaling Equipment (Canada)
MEA
476-91 -E
Vol.13
Jill
01/1/1
S3424
7300-1657:
0229
Standard Features
0 Allows for reliable filtered and regulated power to be installed
where needed
0 Cost effective system expansion
0 Provides for Genesis and Enhanced Integrity notification ap-
pliance synchronization
0 Supports coded output operation
0 Self -restoring overcurrent protection
0 Multiple signal rates
a Can be cascaded or controlled independently
0 Easy field configuration
0 On -board diagnostic LEDs identify wiring or internal faults
0 Standard EDWARDS keyed lockable steel cabinet with re-
movable door
0 110 and 230 Vac models available
0 Accommodates 18 to 12 AWG wire sizes
* Optional tamper switch
0 Dual battery charging rates
0 Optional earthquake hardening: OSHPD seismic pre -approval
for component Importance Factor 1.5
R[_
_7
%7�,E
�Sv �_EW[EjED
JAN 17 2019
MU L D � N 0
Page I of 4
DATA SHEET E85005-0125
Not to be used for installation purposes- Issue 1
Application
Dimensions
The BPS provides additional power and circuits for notification ap-
pliances and other 24 Vdc loads. It is listed for indoor dry locations
and can easily be installed where needed.
Fault conditions are indicated on the on -board diagnostic LEDs,
opening the BPS input sense circuit and the trouble relay (if
programmed). While this provides indication to the host system,
the BPS can still be activated upon command. A separate AC
Fail contact is available on the BPS circuit board, which can be
programmed for trouble or AC Fail. There are seven on -board
diagnostic LEDs: one for each NAC fault, one for battery fault, one
for ground fault, and one for AC power.
The unique dual -input activation circuits of the BPS can be acti-
vated by any voltage from 6 to 45 VDC (filtered- reg u lated) or 11
to 33 Vdc (full -wave rectified, unfiltered). The first input circuit can
be configured to activate 1-4 of the four possible outputs. The
second input circuit can be configured to control circuits 3 and 4.
When outputs are configured for auxiliary operation, these circuits
can be configured to stay on or automatically deactivate 30 sec-
onds after AC power is lost. This feature makes these circuits ideal
for door holder applications. The BPS also has a separate 200
mA 24 Vdc output that can be used to power internal activation
modules.
BPS NACs can be configured for a 3-3-3 temporal or continuous
output. California temporal rate outputs are also available on cer-
tain models. This makes the BPS ideal for applications requiring
signaling rates that are not available from the main system.
D1
t
D5
4 1 0 Top View
D2 -*1 14 -D3
D4 oo
Front View
a)
:2 1
All knockouts
for 3/4 in conduit
(1.9 cm)
D1
D2
D3
D4
17.0 in
3.5 in
13.0 in
6.5 in
(43.2 cm)
(8.9 cm)
(33.0 cm)
(16.5 cm)
In addition to the internally generated signal rates, the BPS can
also be configured to follow the coded signal rate of the main Wire routing
system NACs. This allows for the seamless expansion of existing
NACs.
The BPS enclosure has mounting brackets for up to three Signa-
ture modules to the right of the circuit board.
Engineering Specification
Supply, where needed, EDWARDS BPS Series Booster Power
Supplies (BPS) that are interconnected to and supervised by the
main system. The BPS shall function as a stand-alone auxiliary
power supply with its own fully -supervised battery compliment.
The BPS battery compliment shall be sized to match the require-
ments of the main system. The BPS shall be capable of supervis-
ing and charging batteries having the capacity of 24 ampere -hours
for Mass Notification/Emergency Communication (MNEC), life
safety and security applications, and the capacity of 65 ampere -
hours for access control applications.
<<The BPS shall be capable of installation for a seismic com-
ponent Importance Factor of 1.5.>> The BPS shall provide a
minimum of four independent, fully supervised Class B circuits
that can be field configurable for notification appliance circuits or
auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to
a minimum of two Class A NACs. Each BPS output circuit shall be
rated at 3 amperes at 24 Vdc. Each output circuit shall be pro-
vided with automatically restoring overcurrent protection. The BPS
shall be operable from the main system NAC and/or EDWARDS
Signature Series control modules. BPS NACs shall be configurable
for continuous, 3-3-3 temporal or optionally, California rate. Fault
conditions on the BPS shall not impede operation of main sys-
tem NAC. The BPS shall be provided with ground fault detection
circuitry and a separate AC fail relay
101
E "I.,
�O
CL
CD
CD
D5 D6
3.375 in 12.0 in
(8.6 cm) (30.4 cm)
Power -limited
wiring area
Route AC supply Cal lm�l .0 o
through thec'm
knockouts only 4
(Nonpower-limited
and supervised) Battery wiring (nonpower-
0 limited and supervised) 0
RECEIVED Battery Battery
JAN 17 201t
'if!%
BUILEAWA
Notes
1 . Maintain 1/4-inch (6 mm) spacing between power -limited and nonpower-limited
wiring or use type FPL, FPLR, or FPLP cable per NEC.
[2] Power -limited and supervised when not configured as auxiliary power. Non -
supervised when configured as auxiliary power.
[31 Source must be power -limited. Source determines supervision.
4. When using larger batteries, make sure to position the battery terminals towards
the door.
Page 2 of 4
DATA SHEET E85005-0125
Not to be used for installation purposes. Issue 1
Typical Wiring
Single or cascaded booster
anywhere on a notification appliance circuit
Existing NAC end -of -line resistors are not required to be
installed at the booster's terminals. This allows multiple
boosters to be driven from a single NAC circuit without the
need for special configurations.
Configuring the Booster for
AC Power Fail delay opei
0
TB1 Notification appliance circuit i
i + UL listed
AUX1 EOL 15 1
NAC2/ + Notification appliance circuit (NAC)
AUX2 -:ff
NAC3/ + UL listed
AUX3 - = V Sw I EOL 15 kO
i +
AUX4 -M
200 mAAUX +
Continuous
+
IN
Sense 1 COM
OUT Eff:4
IN FW
Sense 2 COM Fiff
OUT
NO
Trouble COM
NCP
TB2
0
Data in from previous
device or Signature
controller
47 1
CC1(S) module [1][3]
0 0
NAC Circuit
)Jo next signaling
NAC Circuit
F
device, booster, or
VEOL
resistor
Cn (n
3o NAC output #1
Fire Alarm
CD CD
Z) z
W W
NAC output #2
Control Panel
CD (D
NAC output #3
'a -0
NAC output #4
Booster Powerpj
Supli
Multiple CC1 (S) modules using the
BPS'S sense inputs
0 Notification appliance circuit (NAC)
TBI
i +W UL listed
AUXI EOL 15 1
AUX2 Notification appliance circuit (NAC)
i UL listed
AUX3 EOL 15 1
i +Fffl
AUX4
200 mA AUX
Continuous 120
A
IN
Sense 1 COM 19
OUT Fff
IN Fff
Sense 2 COM 19
OUT
NO
Trouble COIM
NCI
T132
0
Data in fro
cleviZe
Data out to
previous next device
or Signature
controller
'The Booster supports AC Power fail delay
Data
out to of three hours via its trouble contact when
next device dip switch SW2-6 is on. All other troubles
are reported to supervising module or panel
without delay via Sense inputs.
Security and access
BPS
T131
24 V
12 V
Security
cu ty
=devicle
AUX1
+
AUX2
+
AUX3 -MJ
+
A 1 v,
IVA
1-0-j
Control panel
[1] Disable the BPS's ground fault jumper (JP3)
=Security
cu ty
device
Card reader Card reader
controller controIll er
+ — + —
47 K
109
CCI(S) module
0 0
CC1(S) module
0 0 - �
[31
i
RECEBUMD
JAN 17 2019
BUILDING
BPS [11
Card reader
controller
+ — I + —
To next
device
or end
Page 3 of 4
DATA SHEET E85005-0125
Not to be used foi installation purposes. Issue 1
Specifications
mod-ei 6.5 amp Booster 10 amp Boosf6r
AC Line Voltage 120VAC or 220-240VAC 5 VAC or 220-240VAC 50/60Hz
390 watts 580 watts
LIFE SAFETY & INCOENT MANAGEMENT Notification Appliance 3.OA max. per circuit @ 24Vdc 3.OA max. per circuit (9 24Vdc
Circuit Ratings nominal 6.5A max total all NACs nominal 1 OA max total all NACs
Contact us...
Email: edwards.fire@fs.utc.com
Web: Edwards-fire.corn
EDWARDS is a UTC brand.
1016 Corporate Park Drive
Mebane, NC 27302
@ 2016 United Technologies Corporation.
All rights reserved.
Trouble Relay 2 Amps 0 3OVdc
Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary
outputs and 200 mA dedicated auxiliary. (See note 2.)
Input Current 3mA @ 12Vdc, 6mA @ 24Vdc
(from an existing NAC)
Booster Internal 70mA + 35 mA for each circuit set to AUX
Supervisory Current
Booster Internal Alarm 270mA
Current
Signature Mounting Accomodates three two -gang modules.
Maximum Battery Size
10 Amp Hours (2 of 12V10A) in cabinet up to 24 Amp hours with ex-
ternal battery cabinet for fire and security applications; up to 65 Amp
hours for access control applications in external battery box.
Terminal Wire Gauge
18-12 AWG
Relative Humidity
0 to 93% non condensing @ 32*C
Temperature Rating
32* to 120*F (0* to 49'C)
NAC Wiring Styles
Class A or Class 8
Output Signal Rates
Continuous, California rate, 3-3-3 temporal,
or follow installed panel's NAC. (See note 1.)
Ground Fault Detection
Enable or Disable via jumper
Agency Listings
UL, ULC, CSFA=
1. Model BPS*CAA provides selection for California rate, in place of temporal. RECEIVED
2. Maximum of 8 Amps can be used for auxiliary output. JAN 17 20119
Ordering Information BUILDING
cati-109
bescni;tlon
Shipping
Number
Wt. lb (kg)
BPS6A
6.5 Amp Booster Power Supply
13(5.9)
BPS6AC
6.5 Amp Booster Power Supply (ULC)
13(5.9)
BPS6A/230
6.5 Amp Booster Power Supply (220V)
13(5.9)
BPS6CAA
6.5 Amp Booster Power Supply with California rate
13(5.9)
BPS10A
10 Amp Booster Power Supply
13(5.9)
BPS10AC
10 Amp Booster Power Supply (ULC)
13(5.9)
BPS10A/230
10 Amp Booster Power Supply (220V)
13(5.9)
BPS10CAA
10 Amp Booster Power Supply with California rate
13(5.9)
1 Requires installation of sepa-
rate battery cabinet.
'Related Equipment
2. BPS supports batteries greater
12V6A5
7.2 Amp Hour Battery, two required
3.4(l.6)
than 24 Amp hours for access
12V10A
10 Amp Hour Battery, two required
9.5(4.3)
control applications only.
3-TAMP
Tamper switch
3. For earthquake anchorage,
including detailed mounting
BC-1 EQ
Seismic Kit for BC-1. Order BC-1 separately. See note 3.
weights and center of gravity
BPSEQ
Seismic kit for BPS6A or BPS10 Booster Power Supplies. See
detail, refer to Seismic Applica-
note 3
tion Guide 3101676. Approval
BC-1
Battery Cabinet (up to 2 - 40 Amp Hour Batteries)
58(26.4)
of panel anchorage to site
structure may require local
BC-2
Battery Cabinet (up to 2 - 17 Amp Hour Batteries)
19(8.6)
AHJ, structural or civil engineer
12V17A
18 Amp Hour Battery, two required (see note 1)
13(5.9)
review.
12V24A
24 Amp Hour Battery, two required (see note 1)
20(9.07)
12V40A
40 Amp Hour Battery, two required (see notes 1, 2)
32(14.5)
12V50A
50 Amp Hour Battery, two required (see notes 1, 2)
40(18.14)
12V65A
65 Amp Hour Battery, two required (see notes 1, 2)
49(22.2)
Page 4 of 4
DATA SHEET E85005-01 25
Not to be used for installation purposes. Issue I
DURACELL SLA Batteries
ULTRA
Duracell' Ultra SLA technology offers high -density power that out-
performs traditional lead acid batteries. The Absorbed Glass Mat (AGM)
construction is designed for efficient gas recombination and allows for
maintenance -free operation,. Duracell' Ultra SLA batteries maintain
their high capacity with a design
that is resistant to damage
caused by deep discharge.
Every Duracell' Ultra SLA
battery is inspected to ensure
the highest standards in
materials and fabrication. law
Cycles at 100% Discharge
2 P E r,*-,L
GUARANTEE
Features:
11
General Purpb'se
Backup and deep cycle applications
• DuracellO Ultra SLA GEL batteries contain a proprietary grid alloy formula combined
with advanced plate curing techniques to provide maximum performance.
• DuracellO Ultra batteries contain a unique electrolyte formula with a special
sub -colloid additive for higher reliability and longer life.
• Will achieve more life cycles than standard AGM and Deep Cycle batteries.
• The unique construction and sealing techniques of these batteries
are guaranteed to give you leak -proof operation.
• Heavy-duty lead calcium tin alloy grids provide an extra margin of performance
and service life in cyclic applications, even after repeated over -discharges.
• Quality Assurance Engineers monitor and control the entire production process.
JAW 17 202
f� -7, �, J) �, L�_ 0 �' X. cz�
• Recycling of used SLA batteries available. � On C LA 2E OIT �
• Delivery available. E]Elm Quantities QQQ.
Lrinn AVAILABLE [:IMM[:]
Sealed
2--
Acid
Maintenance Free Spill Proof
Design
----------
1 Year Stringent Quality
Warranty Control
batteriesplus.com 1-800-677-8278
DUPACELL SLA Batteries
ULTRA
PROJEC T NAME:
CATALOG #
FIXTURE TYPE
NOTES
Batteiry
DURA12-0.8WL
DURA12-1.3F
voks
12V
12V
Capacity Ah (201-Irs) Dimensions (LxWxH Inches)
0.8 3.78 0.98 2.4
1.3 3.82 1.69 2.28
Terminal Type Group Size Weight (Lbs.)
WL 0.77
F1,Tl 1.37
DURA12-2.3F
12V
2.3
6.97
1.38
2.64
FI,T1
2.04
DURA12-2.91'
12V
2.9
3.11
2.2
3.9
F1,T1
- -- ----- ---- ----- --- --
2.36
DURA12-3.3F
12V
3.3
5.28
2.64
2.63
F1,T1
3.18
DURA12-3.3F2
12V
1 3.3
RAYA12-41'
12V
4
3.54
2.76
4.21
F1,T1
DURA12-5F
12V
5
3.54
2.76
4.21
F1,Tl
DURA12-51`2
12V
5
3.56
2.77
3.94
F2, T2
DURA12-5.1A
12V
5.1
5.51
1 1.89
4.21
F1,T1
4.6
I DURA12-5.5F
12V
5.5
1 3.54
1 2.76
3.98
RAYA12-7F
12V
7
------ - -
5.95
--- --
2.56
3.94
F1,T1
DURA12-7F
12V
7
1 5.94
1 2.56
3.94
F1,T1
DURA12-7F2
12V
7
5.94
2.56
2.56
2.56
2.56
3.7
3.94
3.94
3.9
F2, T2
F1,T1
F2, T2
N13, J
.. ........ . ..J
D UR A 1 2-8F
DURA12-81`2
12V 8 5.94
----------
12V 8 5.94
DURA12-9NB
12V 9 5.95
DURA12-91`2
12V
1 9
5.95
2.56
3.94
F2, T2
DURA12-101`2
12V
10
5.95
2.54
4.38
F2, T2
7.5
DURA12-11NB
12V
11
528
3.15
1 6.5
. ...........
10.1
DURA12-12F2
12V
12V
12
12
5.94
5.94
1 3-9
3.86
3.98
3.86
F2, T2
F1,T1
i
DURA12-12F
DURA12 -141`2
12V
14
5.94
3.86
3.98
F2, T2
8.91
DURA12-18F2
12V
12V
18
18
7.13
7.13
303
3.03
657
6.57
F2, T2
N13, J
12.43
20.7
27.3
38
DURA12-18NB
DURA12-26NB
12V 26 6.5 6.93 4.92 N13, 1
12V 35 7.72 5.16 1 6.5 C
12V 46 7.8 6.54 6.85 C
DURA12-35C
DURA12-44C/FR
DURA12-55C/FR
12V
12V
12V
12V
V
55
80
j 100
140
4.5
9.02
10.24
12.09
13.43
1.85
5.43
6.65
6.65
6.81
1.85
8.35
8.46
8.46
11.3
3.98
C
C
C
F2, T2
............
42.1
DURA12-80C/FR
i
DURA12-100CH
DURA12-14OC/FR
DURA4-4.5F2
74.6
108
1.4
DURA6-1.3F
6V
1.3
i 3.82
1.69
0.94
1.45
2.28
2.99
F1,T1
__�__0.7115
DURA6-2ST
6V 2
ST
1
0.75
DURA6-2.9F
6V
2.9
2.6
5.28
1.46
3.82
2.64
T-rl T,
F1,T1
1.26
1.65
DURA6-3.3F
6V
F1j1
RAYA6-4F
6V
4
2.76
1.85
4.13
F1,T1
---DURA6-5SP
6V
5
2.6
5.94
3.9
5.94
1 2.6
1.85
1.34
2.24
1.97
4.53
4.21
3.68
4.53
3.98
SP
Fl,T1
F1,T 1, IAW 1
two"
F1,T1
------ ------- - ---
7 Q
--.2.-09----
2,43
3.8
4.851
DURA6-5F
DURA6-7.2F
6V 5
6V 7.2
DURA6-8.2F
DURA6-10F
6V 8.2
6V 10
DURA6-12F
6V
6V
6V
6V
12
12
14
14
5.94
5.94
4.25
4.25
1.97
1.97
2.8
2.8
3.98 F1,TI
3.98 F2, T2
5.51 H
5.51 F1 F2 (+), T1 (-) T2 FP
. . . . .................. ..... .
4.602
DURA6-12F2
RAYA6-14T2
. ... ...
6.24
........ I ........... ....... -
6.16
DURA6-14A
DURA6-42F2
6V
42
6.25
3.37
6.37
F2, T2
16.64
DURA6-42NB
6v
6V
8v
42
200
3.2
6.34
.. . .......... .. ......
2.05
5.28
1 3.43
.......
6.65
1.44
6.42
8.63
2.48
N13,1
C
F1, TI
16.62
1 . 65
DURA6-200C
DURA8-3.2F
r! 0
Visit batteriesplus.com for warranty information FO-) <Q'Z 0�5
0 2017 DURACELL. Bethel, C1706801. Duracel I is a registered trademark of Durace I I U.S. Operations, Inc., used under I! came. All rights resemd. P) MT- 7�� C . Rt' U S
EDW'ARDS Catalog > Intelligent Input -Output
�, ww
i nite ec no 0
f, glie
LIFE SAFETY 65' INCIDEN-F MANIA(3EMENT
Synchronization
Output Module
SIGA-ClClS, MCClS
Overview
SIGA-CC1 S and MCC1 S Synchronization Output Modules are in-
telligent analog addressable devices that form part of EDWARDS's
Signature line of products. The actual operation of the SIGA-CC1 S
and MCC1 S is determined by the "personality code" selected by
the installer, which is downloaded to the module from the Signa-
ture loop controller during system configuration.
Depending on their assigned personality, Synchronization Output
Modules may be used as a signal power riser selector to provide
synchronization of fire alarm signals across multiple zones, or for
connecting, upon command from the loop controller, supervised
Class B signal or telephone circuits to their respective power
inputs, The power inputs may be polarized 24 Vdc to operate au-
dible and visible signal appliances or 25 and 70 VRMS to operate
audio evacuation speakers and firefighter's telephones.
RMETWIFE),
JAN 17 2019
BUILDING
11177 Patented
7300-1657:
MEA 0121 S3424
Standard Features
Provides UL 1971 -compliant auto -sync output for visual
signals
Use for connecting a supervised output circuit to a supervised
24 Vdc riser input and synchronizing multiple notification appli-
ance circuits.
• Functions as an audible signal riser selector
Use as a synch module or for connecting supervised 24 Vdc
AudibleNisible signal circuits, or 25 and 70 VRMS Audio
Evacuation and Telephone circuits to their power inputs.
• Built-in ring -tone generator
When configured for telephone circuits, the SIGA-CC1 S gener-
ates its own ring -tone signal, eliminating the need for a sepa-
rate ring -tone circuit.
• Automatic device mapping
Signature modules transmit information to the loop controller
regarding their circuit locations with respect to other Signature
devices on the wire loop.
• Electronic addressing
Programmable addresses are downloaded from the loop con-
troller, a PC, or the SIGA-PRO Signature Program/Service Tool;
there are no switches or dials to set.
Intelligent device with microprocessor
All decisions are made at the module to allow lower com-
munication speed with substantially improved control panel
response time and less sensitivity to line noise and loop wiring
properties; twisted or shielded wire is not required.
Page I of 4
DATA SHEET' E85001-0543
Not to be used for Installation purposes. Issue 1.1
Application
The SIGA-CC11S mounts to a standard North American two -gang
electrical box, making it ideal for locations where only one module
is required. Separate 1/0 and data loop connections are made to
each module.
The SIGA-MCCIIS is part of the UIO family of plug-in Signature
Series modules. It functions identically to the SIGA-CC1 S, but
takes advantage of the modular flexibility and easy installation that
characterize all UIO modules. Two- and six -module UIO mother-
boards are available. These can accommodate individual risers for
each on -board module, or risers that are shared by any combina-
tion of its UIO modules. All wiring connections are made to termi-
nal blocks on the motherboard. UIO assemblies may be mounted
in EDWARDS enclosures.
Personality Codes
The operation of the SIGA-CC1 S is determined by their sub -type
code or "Personality Code". The code is selected by the installer
depending upon the desired application and is downloaded from
the loop controller.
Personality Code 5: Signal Power or Audio Evacuation (sin-
gle riser). Configures the module for use as a Class B Audible/
Visible Signal power (24 Vdc polarized) or Audio Evacuation (25
or 70 VRIVIS) power selector. The ring -tone generator is disabled.
The output circuit is monitored for open or shorted wiring. If a
short exists, the control panel inhibits the activation of the audible/
visible signal circuit to prevent connection to the power circuit.
Personality Code 6: Telephone with ring -tone (single riser).
Configures the module for use as a Telephone power selector.
When a telephone handset is plugged into its jack or lifted from its
hook, the module generates its own Ring -Tone signal. A separate
ring -tone circuit is not needed. The module sends this signal to
the control panel to indicate that an off -hook condition is present.
When the system operator responds to the call, the ring -tone
signal is disabled.
Personality Code 25: Visual Signal Synchronization. This
personality code configures the module to provide synchronization
of fire alarm signals across multiple zones. It functions as a signal
power (24 Vdc) riser selector The output wiring is monitored for
open circuits and short circuits. A short circuit will cause the fire
alarm control panel to inhibit the activation of the audible/visual
signal circuit so the riser is not connected to the wiring fault.
Warnings & Cautions
This module will not operate without electrical power. As fires fre-
quently cause power interruption, we suggest you discuss further
safeguards with your fire protection specialist.
EDWARDS recommends that these modules be installed accord-
ing to latest recognized edition of national and local fire alarm
codes.
Compatibility
These modules are part of EDWARDSs Signature Series intelligent
processing and control platform. They are compatible with EST3,
EST3X and iO Series control panels.
Installation
The SIGA-CCIS: mounts to North American 2-1/2 inch (64 mm)
deep 2-gang boxes and 1-1/2 inch (38 mm) deep 4 inch square
boxes with 2-gang covers and SIGA-MP mounting plates. The
terminals are suited for #12 to #18 AWG (2.5 MM2 to 0.75 MM2)
wire size.
SIGA-MCC IS: mount the UlOxR motherboard inside a suitable
EDWARDS enclosure with screws and washers provided. Plug the
module into any available position on the motherboard and secure
the module to the motherboard with the captive screws. Wiring
connections are made to the terminals on the motherboard (see
wiring diagram). UIOxR motherboard terminals are suited for #12
to #18 AWG (2.5 Mil to 0.75 mm2) wire size.
UIO Motherboard
6-32
Self -tapping
screws
Plug-in (UIO)
Captive
Module
screws
CE
46 Flat washers
JAN 17 2019
— cabinet or electrical enclosure BUILDING
Electronic Addressing
The loop controller electronically addresses each module saving
valuable time during system commissioning. Setting complicated
switches or dials is not required. Each module has its own unique
serial number stored in its "on -board memory". The loop control-
ler identifies each device on the loop and assigns a "soft" address
to each serial number. If desired, the modules can be addressed
using the SIGA-PRO Signature Program/Service Tool.
Testing & Maintenance
The module's automatic self -diagnosis identifies when it is defec-
tive and causes a trouble message. The user-friendly maintenance
program shows the current state of each module and other perti-
nent messages. Single modules may be turned off (de -activated)
temporarily, from the control panel.
Scheduled maintenance (Regular or Selected) for proper system
operation should be planned to meet the requirements of the
Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and
ULC CAN/ULC 536 standards.
Page 2 of 4
DATA SHEET E85001-0543
Not to be used for installation purposes. Issue 1.1
Typical Wiring
SIGA-CCIS (Standard Mount)
Personality Typical Speaker Cir cuit
C ode 5
UIJULC Listed
MOEDO 47K Ohm EOL
Pe rsonality Typical Telephone Circuit
Code 6
UL/ULC Listed
C C 41K Ohm EOL
Personality Enhanced Integrity and Genesis Devices
Cocle25
IJIJULC Listed
47KOhmEOL
ccis
Q 0
SIGA-MCCIS (Ul0 Mount)
Green LED (Normal
Riser out (+)
TO ne4 device Riser out ed LED (ActNe
Riser in(+) , From control pane. Data out
Riser in 1-) 3 To next device or EOL I esivo, Data out W
Data in(+) j F,ornSignatureContsoller—
Data in(-) 3 or Previous D"lice —
Multiple CC1(S) modules using the BPS'S sense inputs
TB 10
Notification appliance circuit (NAC)
NAC1/
AUX1
ULli,t,d
EOL 15 K Ohms
NAC2/ +
AUX2
Notification appliance circuit (NAC)
NAC3/ +
AUX3
UL listed
EOL 15 K Ohms
NAC4/ +
AUX4
200 mA AUX
Continuous Com--
1--
IN
rw
+
z--
Sense I COM
OUT
IN
[ff
EK
�EOL 47 K
Sense 2 COM
OUT
-EOL 47 K
NO
Trouble COM
NC
109
109
r-,(S.)
CC 1 (S) module
CCI(S�) module
0 .4o' - -
CL - �
[31
Personality Typical Speaker Cir cuit
Code 5
UIJULC Listed
[::0EDa 47K Ohm EOL
Personality Typi ca I T el ephone Cir cuit
Code 6 It
UL/ULC Lived
C C 41K Ohm EOL
Personality Enhanced Integrity and Genesis Devices
Code25
Y Y V ULAJLC Listed
PE:�Da 47K Ohm EOL
1 2 3 4
Q1, 4
0
1 2 3 4
Rise, I In +!::::�j I L_ 1 Rise, I Out
UIO(R) series motherbwr d
+ Rise, I Out
+ Riser I In
JAN 17 2019
BUILDING
Page 3 of 4
DATA SHEET E85001-0543
Not to be used for installation purposes. Issue 1.1
� EDWARDS
�_c
LIFE SAFFETY & INCIDENT MANAGEMENT
Contact us...
Email: edwards.fire@fs.utc.com
Web: Edwards-fire.corn
EDWARDS is a UTC brand.
1016 Corporate Park Drive
Mebane, NC 27302
@ 2016 United Technologies Corporation.
All rights reserved.
Specifications
FCatalog Number
SIGA-CCIIS —
1—slnfi�-Moc_is
North American 21/2 inch (64 mm)
deep two -gang boxes and 11/2
Plugs into U102R, U106R or U106
Mounting
inch (38 mm) deep 4 inch square
Motherboards
boxes with 2-gang covers and
SIGA-MP mounting plates
Description
Synchronizatio n Output Module
Type Code
50 (factory set)
Address Requirements
Uses one module address
Wiring Terminations
Suitable for #12 to #18 AWG (2.5 MM2 to 0.75mm9
Standby 223pA
Operating Current
Activated 1 OOpA
Operating Voltage
15.2 to 19.95 Vdc (19 Vdc; nominal)
24 Vdc = 2 amps
Output Rating
25 V Audio = 50 watts
70 V Audio = 35 watts
Construction
High Impact Engineering Polymer
Operating: 32*F to 120oF (OoC to 49oC)
Storage and Operating
Storage: -4oF to 140'F (-20oC to 60'C)
Environment
Humidity: 0 to 93% RH
Green LED - Flashes when polled Red LED - Flashes when in alarm/
LED Operation
active
Compatibility
Use with: Signature Loop Controller under EST3 version 2.0 or higher
Agency Listings
UL, ULC, CSFM, MEA
Ordering Information
Catalo Shipping Wt.
Description
Number Ibs (kg)
III, SIGA-CC1S Synchronization Output Module (Standard Mount) - UUULC Listed 0.5(0.23)
SIGA- Synchronization Output Module (UIO Mount) - UL/ULC Listed 0.18(0.08)
MCC-1 S
�Relatq;d__Eq'u_ ip-Went - --- _. — _. -_ --- - __. - —_ - - . ---I
27193-21 Surface Mount Box - Red, 2-gang 2(1.2)
27193-26 Surface Mount Box - White, 2-gang 2 (1.2)
SIGA-UI02R Universal Input -Output Module Board w/Riser Inputs 0.32(0.15)
_ Two Module Positions
SIGA-UI06R
Universal Input -Output Module Board w/Riser Inputs
- Six Module Positions
0.62(0.28)
SIGA-UI06
Universal Input -Output Module Board - Six Module Positions
0.56(0.25)
235196P
Bi-polar Transient Protector
0.01 (0.05)
MFC-A
Multifunction Fire Cabinet - Red,
supports Signature Module Mounting Plates
7.0(3.1)
SIGA-MP1
Signature Module Mounting Plate, 1 footprint
1.5(0.70)
SIGA-MP2
Signature Module Mounting Plate, 1/2 footprint
0.5(0.23)
SIGA-MP2L
Signature Module Mounting Plate, 1/2 extended footprint
1.02 (0.4�)__
JAN 17 2019
BUILDING
Page 4 of 4 DATA SHEET E85001-0543
Not to be used for installation purposes. Issue 1.1