BLD20181165OV EDAf '6 LA CITY OF EDMONDS 1 5 21 TH AVENUE NORTH -EDMONDS, WA 98020 v& PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 01/22/2019 1 Pennit #: BLD20181165' BUILDING PERMIT Expiration Date: 07/22/2019 Project Address: 20904 72ND AVE W, EDMONDS Parcel No: 00566900200302 PROPERTY OWNER APPLICANT CONTRACTOR CUMMINGS DEVELOPMENT LLC CASCADIA FIRE PROTECTION I ST FIRE SOLUTIONS, LLC 10701 128TH AVE NE PO BOX 206 C/O RICK BERGER KIRKLAND, WA 98033 PUYALLUP, WA 98371 4210 AUBURN WAY N #7 AUBURN, WA 98007 (425) 890-3397 (253) 202-3 909 (425) 891-4909 LICENSE #- I STFIRS86]DF EXP:06/22/2019 JOB DESCRIP'YON Multifamily stand alone F/S system VALUATION: $10,000 PERMIT TYPE: Commercial PERMIT GROUP: 30 - Fire Sprinkler GRADING N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: 0 X 0 FT.) CODE: IOTHER: ------- OTHER DESC: IZONE: INUMBER OF STORIES: 0 IVESTEDDATE: NUMBER OF DWELLING UNITS: 0 LOT 4: IMMIN BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 3 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS: 0 BATHROOMS: 0 BEDROOMS: 0 BATHROOMS: 0 FRONTSEI'BACK SIDESETRACK REAR SETBACK REQUIRED: PROPOSED: EQUIRED: PROPOSED: IREQUIRED PROPOSFD HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED SETBACK NOTE& I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EIMPLOY ED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATI(;4N IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HISMER DEPUTY AND ALL FEES ARE PAID. Date By 1/22/19 Date ATTENTION ITIS UNLAWFUL TO USE OR OCCUPY A BUILDrNG OR STRUCTURE UNTIL A FFNAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GPANTFD. UBC109/ IBC1 I01IRCI 10. = FW = APPLICANT = ASSESSOR w STATUS: ISSUED BLD20181165 • Final approval on a projector final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00arn to 6:00pin on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harinless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly ftom the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRKIB/VAYS, MARQUEES, ErC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A) (6) BUILDING ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: wmiv.edmondswa.gov Building Department Inspections 2. Then: SeNces are now scheduled online. If you FIRE (425) 775-7720 3. Then: Perm its/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0236 5: If you don't have one already, create a assistance during office hours. login (upper right hand corner) (425) 771-0220 RECYCLING (425) 275-4801 6: Schedule your inspection I I I When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Acceptance BUILDING PERMIT Office Use Only APPLICATION Permit #: Development Services Building Division 121 Sth Ave N / Edmonds, WA 98020 11C. Ib7 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: http://www.edmondswa.gov/ JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: � 0(an e--1 -7 Z ND AV F- W- Parcel: Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: Name: Ha'Y-K Mailing Address: Lo o I I ZO W \j t City/State/Zip: Vk'irk-Ac,,-,�k , ('��A q3-6 ? Phone#:6/20 ?xo---?3C17 Email: Q:�-c \6,-P-yqe,, cor:�> AD tAoA P--\; cwi, 4 — OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? El Yes 0 No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: CCA.-Sccck-k k F `ly-C �'c-c)Ae c:J--o k-%. Mailing Address: o. box- 2&� City/State/Zip: PAVr'L1(kP' Phone#: E-mail: D�1- cq-5cowL'C"A C)VA GENERAL CONTRACTOR: (if different from applicant) General Contractor: Mailing Address:_ City/State/Zip: Phone #: E-mail: WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: CITY OF EDMONDS BUSINESS LICENSE #: TYPE OF PERMIT (Provide El Accessory Structure/ Detached Garage Details on Page 2) El Addition 11 Demolition El Mechanical El New Single Family/ Duplex El Plumbing )k/,Fir e Sprinkler 0 Remodel 0 New Commercial/ Mixed Use 0 Re -Roof 0 Signs 0 Tank 0 Tenant Improvement El Other Remodel Perml fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materiials, labor, overhead, and the profit for the work indicated on this application. Valuation: /6, 6 Q & PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement sq ft: Finished 0 Unfinished El 1st Floor, sq ft: 2nd Floor, sqft: Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other sq ft: PROJECT DESCRIPTION k�'C'c Y�s 4-e- ki- certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the prope owner to submit a permit application to the City of Edmonds. Print Name: Signature: Date V2 GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes El No El WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec Other QtY A/C Unit /Compressor Air Handier /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty Qty Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Toilets Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y/N PSCAA Case #: Critical Areas Determination: Study Required El Conditional Waiver El Waiver El Fill in Place El Fill Material: Removal El Size of Tank (Gallons) Critical Areas Determination: Study Required 1:1 Conditional Waiver El Waiver El GRAD E/FI LL/ EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes 1:1 No GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. MATERIAL SUBMITTAL AND HYDRAULIC CALCULATIONS FOR EDMONDS MULTI -UNIT 2090472 ND AVENUE W EDMONDSJ. WA 98026 BY L aov%� Uascadia FIRE PROTECTION I goll Q �111 il PUYALLUP, WA 98371 9 AUG 2 i u!; s I LrL, u i ll� G -A L'o a-s EDMONDS MULTI -UNIT TABLE OF CONTENTS FIRE SPRINKLERS RELIABLE MODEL RFC49 RESIDENTIAL CONCEALER SPRINKLER RELIABLE MODEL G5-56 CONCEALER SPRINKLER RELIABLE MODEL DH56 DRY SIDEWALL SPRINKLER FIRE SPRINKLER VALVES AMES 2000B DOUBLE CHECK VALVE ASSEMBLY PIPE AND FITTINGS HARVEL CPVC FIRE SPRINKLER PIPE SPEARS FLAMEGUARD CPVC FITTINGS HANGERS ANVIL FIGURE 184 DOUBLE OFFSET HANGER AND RESTRAINER ANVIL FIGURE 187 TWO HOLE SIDE MOUNT STRAP ANVIL FIGURE 188R TWO HOLE STANDOFF AND RESTRAINER MISCELLANEOUS MATERIALS RELIABLE RESIDENTIAL RISER POTTER RBVS UNIVERSAL BALLVALVE SWITCH HYDRAULIC CALCULATIONS UNIT 201 (RESIDENTIAL) FIRE SPRINKLERS ®R R liable A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpni/ft2with low GPM requirements. Features 1 . Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with 1/2" (13mm) Total adjustment. 3. Thread-On/Thread-Off or Push-On[Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprin- kler patterns. The combination of speed of operation and high dis- charge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacu- ation time for occupants. The RFC30, RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive ap- pearance and 1/2" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily Bulletin 006 Rev. I Model RFC30 (SIN RA061 1) Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) Residential Flat Concealed Sprinklers Hiain uover Hiate ------------ ------------- ---------------- Perforated Cover Plate and positively attached and blends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. The RFC30, RFC43 and RFC49 are UL Listed Residen- tial Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 13D. The RFC30, RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit ac- curately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. D 0 0 CY) M CD Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- lations, use a 165'F (74'C) fusible solder link in a tun- ing fork style sprinkler frame with a drop -down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135OF (570C) ordinary temperature classifica- tion solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the de- flector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler de- flector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop -down deflector is properly located below the ceiling. The resi- dential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces sig- nificantly higher wall wetting. After a 25/a inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexago- nal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe instal- lation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprin- kler/cup assembly, care should be taken to prevent dam- age to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY, MODEL RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135"F RATED COV- ERS. Note: A leak tight 1/2" NPT (R1/2) sprinkler joint can be ob- tained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Cover assemblies provide up to 1/2" (13mm) of adjust- ment. Turn the cover clockwise until the flange is in con- tact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final ad- justment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover re- moval requires turning in the counter -clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or neg- ative pressurization but must not be positively pres- surized. Inspect all sprinklers after installation to en- sure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Model Thread Nominal Sprinkler CCP Assembly Max. Ambient K Max. (SIN) Size Orifice Temp Rating Temp. Rating Temp. Factor Pressure Inch (mm) Inch (mm) psi (bar) OF OC OF OC OF I OC RFC 30 (RA061 1) 1/2" (15) 2'/64 (8,2) 165 74 135 57 100 38 3.0(43.2) 175(12) RFC 43 (RA0612) 112" (15) 3/"(10) 165 74 135 57 100 38 4.3(62) 175(12) RFC 49 (RA0616) (15) 7/,.6 (11) 165 74 135 57 100 38 4.9(70.6) 175(12) Note: 1 bar = 100 Kpa RFC 30 Ordinary Temp. Rating Max. Coverage Max. Spacing (1 65'F/74-C) Top of Deflector Installation Minimum area Ft x Ft (m x m) Ft (m) to Ceiling Inch (mm) Type Spacing Ft (m) Flow Pressure GPM (Umin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) Smooth Ceilings 1/2 to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) ___ 14 x 14 (4,3 x 4,3) 14(4,3) 10(37,8) 11 0 (0,76)] 13 installed in beams 1/2 to 1 (13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Ordinary Temp. Rating Max. Coverage Max. Spacing (1 65'F/74-C) Top of Deflector Installation Minimum area Ft x Ft (m x m) Ft (m) to Ceiling Inch (mm) Type Spacing Ft (m) Flow Pressure GPM (Umin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) Smooth Ceilings 1/2 to 1 (13 to 25A) 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) 16 x 16 (4,9 x 4,9) 16(4,9) 13(49) 9.1(0,63) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1 (13 to 25.4) Concealed 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 18(68) 17.5(l.21) 20 x 20 (6,1 x 6, 1) 20(6,1) 21 (79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Max. Coverage Ordinary Temp. Rating Top of Deflector Minimum area Max. Spacing (165' VC) to Ceiling Installation Spacing Flow . Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Type Ft (m) GPM ( in) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3.6) 13(49) 7.0(0,48) Smooth Ceilings 1/2to 1 (13 to 25.4) 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7,0(0.48) 16 x 16 (4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2to 1 (13 to 25.4) Concealed 8(2.4) 18 x 18 (5,5 x 5,5) 18(5,5) 17(64,3) 12.0(0,83 20 x 20 (6,1 x 6, 1) 20(6.1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Model RFC30, RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential con- cealed sprinklers with drop -down deflector and adjust- able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a '/;," NPT thread. Thermal element shall consist of an approved black -painted beryllium -nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon -coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K- factor shall be nominal 3.0 (43.2), 4.3 (62), and 4.9 (70.6) having a 5/1r,", 3/8" and 7/16" orifice. Temperature rating shall be Ordinary 165'F (74'C); cover plate temperature rating to be 1350F (57C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a '/;?" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop -down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop -down sprinkler deflector from dam- age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). 3. Ordering Information Specify: 1. Sprinkler Model 2. Cover Plate Finish 3. Thread -On or . Push -On Feature Cover Plate Finishes0) Standard Finishes Chrome -White Paint Special Application FinisheS(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. I' x 112' REDUCING TEE OR ELBOW 2j' [58.42.,n] H&E IN CEILING D14 CUP 2 - [50 8mm] MAX FACE OF F7MNG [12.70mm] MAX. TO FACE OF' CE7UNG COVER ADJUSTWENT Li DIMENSION 112- [12.70mm] MIN, TO I' [25.4mml MAX. CEILING DROPPED DEFLECTOR 710 CEIU����� FLAT COVER PLATE ASSEMBLY JA- [84.21mm] DIA. \--CE7LJNG [4.96mm] COVER PLATE 112" L12.7mml ADJUSTA4ENT 009WIC The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address 9 Recycled Paper Revision lines indicate updated or new data. EG, Printpd in U.S.A. 11/ 14 P/N 9999970261 Bulletin 034 Rev. D Model G5-80, Model G5-56, Model G5-42, Model G5-28 Bel ble Quick Response Concealed M Automatic Sprinkler UL Quick Response FM Standard Response Concealed Sprinkler With a 3 /4" (1 9mm) Adjustment Features 1 . Cover plate attachment (Plain or Perforated) with 3/4" (1 9mm) assembly adjustment. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28 - Light Hazard Occupancies 2. Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) • G5-56 & G5-28 only. • See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention Council (LPCB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies 4. VdS SchadenverhOtung GmbH - Standard Response 5. EC -Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetc appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop -down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135OF (57'C) or 1650F (741C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop -down deflector is properly located below the ceiling. co C: CD 0 CD LU Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. Cut a 25/8" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler, The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/ CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing, A protective cap is provided to protect the drop -down sprinkler deflector from damage which could occur during construction before the cover plate is installed, The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and (35-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Ordering Information 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Plain or Perforated 4. Flat Cover Plate Assembly Finish 5. Inlet Type Cover Plate Finishes0) Standard Finishes Chrome White Paint Special Application FinisheS(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) For the Perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. "i am"S 0 -0 7130OV4' Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Max. Ambient Plate Temp. Ordinary 165'F/74'C 135'F/57*C 100'F/38'C Intermediate I 212'F/100'C , 165*F/74'C- 150'F/66'C 2. Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K F ctor Thread Approvals Sprinkler Identification (SIN) — US I Metric G5-80 Non Adjustable 3/4" 11A2" (15mm) 8,0 115 3/4" NPT (R3/4) 1 RA3412 G5-56 Non Adjustable 3/V (19mm) 1/;-," (15mm) 1 5.6 80 1/2 IN P T (19 112) 1,2,3,4,5 RA3415 G5-42 Non Adjustable -1K " (119 m rn) 1/,," (10mm) 4.2 60 1/, N P T (19 112) 1 RA3413' G5-28 Non Adjustable :1/4" (19mm) IN' (10MM) 2.8 40 112" NPT (191/2) 1.2 RA3411 For VdS Approval, temperature rating sprinkler 165OF/74'c and cover plate 1350F/57C only! I" x 112 " REDUCING TEE OR ELBOW I- - J14" REDUCING �EF OR CL80W G5-80 ONLY [58.42mml DIA CUP ------ — J- [19.05��] MAX. COVER ADJUSTMENT 114 [6 35mml A41N TO CEILING I" [25.4mm] MAX. DROPPED DEFLECTOR TO CEILING F7AT COVER PLATE ASSEMBLY SPRINKLER 3,J- [84.21mml DIA. --A L06. MMJ HOLE IN CEILING 7 2-114" [SZ 15mm] MAX FACE OF FITTING TO rACE OF CEILING DIMENSION it- [4.96mm] 00�18 COVER PLATE: j14" 1'19.05mmZ ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS I' x 112" REDUCING TEE OR ELBOW RELABLE PIN 6999991900 J" X J" BRASS NIPPLE EX7:----, ILR6-, 2J- [58.42mml DLA CUP J- [19.05��] MAX. COVER ADJUSTMENT 114' [6.35mm] MIN. TO CEILING I" [25.4mml MAX. DROPPED DEFLECTOR TO CEILING FLAT COVER PLATE_1 I ASSEA48L Y SPRINKLER 4- [84.21mm] DIA. 2J' [66.55,nml HOLE IN CEILING 3- 1 .72mml MAX. A FACE OF FITTING TO FACE OF CEILING DIMENSION 2-114- [5715mm] MAX. FACE OF NIPPLE EXT TO FACE OF CEILING DIMENSION li- [4.96m�] 0J4FGM COVER PLATE: J114" L19.05mm-1 ADJUSTMENT 1. Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler . 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". 3. Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable...For Complete Protectior Reliable offers a wide selection of sprinkler components, Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. 9 Automatic sprinklers e Flush automatic sprinklers e Recessed automatic sprinklers 9 Concealed automatic sprinklers o Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers 9 Open sprinklers * Spray nozzles * Alarm valves * Retarding chambers is Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches 9 Water flow detectors * Deluge valves o Detector check valves 9 Check valves 9 Electrical system * Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards * Inspectors test connections o Sight drains o Ball drips and drum drips * Control valve seals 9 Air maintenance devices • Air compressors • Pressure gauges e Identification signs 9 Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address JQ4 Recycled %V Paper Revision lines indicate updated or new data. EG. Printed in USA 11/14 P/N 9999970421 Bulletin 016 Rev, H R Model DH56 HSW ®R) Model DH56 HSW Recessed Model DH56 HSW Concealed biLl Quick Response, Extended Coverage Dry Sprinklers For coverages up to 28 feet wide and 10 feet long0). 250 psi (17,2 bar) rated. Features: 1 . Coverage for long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet wide and 10 feet long.0) 2. Deflector to ceiling dimensions are: 4" (102mm) min. to 12" (305mm) max. 3. Minimum spacing between sprinklers 16 feet (4.9m).0) 4. Polyester Coated or Electroless Nickel PTFE (Teflon")* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. 5. UL Listed for extended coverage, light hazard applications. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi (17,2 bar) applications. 8. Quick response performance. 9. 1/2" (1 3mm) adjustment of escutcheon and cover. 10. Concealed cover plate can prevent the sprinkler from being used for unintended purposes, No exposed thermal element with the concealed version. 11. Push-or0hread-off sturdy convenient escutcheon for recessed and cover for concealed. 12. Factory assembled sprinkler & cup, shipped complete with bulb protector for concealed and FP recessed versions. 13. Sprinkler & cup assembly and escutcheon or cover are separately packaged. 14. Available in a variety of plated and painted finishes (1) See Fig. 9. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (cULus) 2. NYC MEA 258-93-E Patents US Patent No. 7,841,418 Other Patents Pending Products Description The Model DH56 are quick response extended cover- age sidewall dry sprinklers for use in light hazard applica- tions. The Model DH56 dry sprinkler with SWC cover plate is a concealed sprinkler that uses Reliable's push on/thread off sidewall cover. This sprinkler has the cup factory mounted and is shipped with a bulb protector that protects the 3mm frangible glass bulb during shipping and post installation fin- ishing operations. The DH56 can be combined in the field with the FP Escutcheon to make a recessed dry sprinkler *DuPont Registered Trademark DH56 HSW (See Fig. 4) DH56 HSW/HB (See Fig. 5) DH56 HSW FP Recessed (See Fig. 6) DH56 HSW Concealed with SWC coverplate (See Fig. 7) The SWC cover plate and FP recessed escutcheons have 112" adjustment. The SWC cover plate is attached with 135 & 165 degree solder. In the event of a fire the rising ambient temperature melts the solder and the cover plate is ejected away by springs exposing the 3mm frangible glass bulb. The use of a 3mm bulb allows quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the same temperature rating. Model DH56 dry sprinklers are intended for use in dry and preaction systems to protect areas subjected to freez- ing temperatures and unheated portions inside and outside buildings. See Fig. 1 for guidelines on using dry sprinklers in wet systems. (D 0 0') no Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple. The wax must not be removed. Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in ac- cordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8,5m) wide and 10 feet (3m) long. They are rated for 250 psi (17,2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. General Installation Instructions Model DH56 dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 1. Caution: Do not install Model DH56 HSW Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 8 DH56 HSW To install the DH56 HSW dry sprinkler cut a 21/8" diameter hole in the wall as shown in Fig. 4. Use the Model F3 instal- lation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting'. Apply a Teflon* based sealant to the sprinkler threads before install- ing in the sprinkler. Installation is completed by removing the orange glass bulb -protector and assembling the slip-on escutcheon to the sprinkler's can. DH56 HSW/HB To install the DH56 HSW/HB dry sprinkler cut a 2112" di- ameter hole in the wall as shown in Fig. 5. Use the Model F3 installation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting'. Apply a Teflon* based sealant to the sprinkler threads be- fore installing in the sprinkler. Installation is completed by removing the orange glass bulb -protector and assembling the slip-on escutcheon to the sprinkler's can. DH56 HSW Recessed with FP Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutch- eon as a recessed sprinkler cut a 25/8" diameter hole in the wall as shown in Fig. 6. Temporarily remove the plastic pro- tective cap, and then use the, Model XL02 wrench' (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XL02 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler, It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the push -on escutcheon. Turn clockwise to adjust the escutcheon against the wall. DH56 HSW Concealed with SWC Cover Plate To install the DH56 HSW dry sprinkler with the SWC cover - plate as a concealed sprinkler, cut a 21/8" diameter hole into the wall as shown in Fig. 7. Temporarily remove the plastic protective cap, and then use the Model XL02 wrench' (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XL02 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the coverplate. Coverplate as- semblies provide 1/2" (13mm) of adjustment, Final adjust- ment is made by turning the coverplate clockwise until the skirt flange makes full contact with the wall surface. Cover removal requires turning in the counter -clockwise direction. Concealed coverplate assemblies are listed only for use with specific sprinklers. The use of any other concealed wall sprinkler or the use of the SWC coverplate on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. Note: DH56 and DH56 Recessed Sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDO- ING THE CLASP BY HAND. DO NOT USE TOOLS TO RE- MOVE THE PROTECTORS. Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly (Item #8 on fig 10). Keep On mind that a pipe wrench will incomorate a larae amount of torque nto the f nal assembly This toLque will have to be matched or exceeded upon the sprinkler's removal at a later date, *DuPont Registered Trademark 2. RECOMMENDED MINIMUM EXPOSED BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DH56 IHSW DRY SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREA- AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 4aF/IVC I WF/lOC I WF/IIrC EXPOSED WNIMUM BARREL LENGTH" (FACE OF TEE TO TOP OF CEILING) w. (MM) IN. (MM) IN. (MM) 40`F (,VC) 0 0 0 3qF (-I-C) 0 0 0 20-F (--rC) 4 (101) 0 0 IO`F (-lZC) 8 (203) 1 (25.1) 0 0-F (-18-C) 12 (305) 3 (75) 0 -10-F (-2-TC) 14 (356) 4 (101) 1 (25.1) -20'F (-2WC) 14 (356) 6 (152) 3 (75) -30-F (-347C) 10 (406) a (203) 4 (101) -40-F (-17C) 18 (457) 8 (203) 4 (101) -WF (-44TC) 20 (506) 10 (254) 6 (132) -WF (-51-C) 20 (5011) 1 10 (254) 6 (152) 'A' DIMENSION MINIMUM CLEARANCE EXPOSED HOLE BARREL LENGTH (HEATED AREA) THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEIUNG- - — - — - — - — - — - — THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRNKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED. USE THE NEXT COOLER TEMPERATURE "THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE W DIMENSION. WIET NaM' EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP M 3OMPH PIPE WIND VELOCITIES IN THE PROTECTED AREA. ............... MAL) I INCH NPr THREADED END OF DRY PENDENT SPRINKLER INTO THE I INCH NPT SIDE OUTLET OF A MALLEABLE IrN FMM CL 2EI PER ANSI 8 18.3 A 50) OR CAST IRON THRE-1 PER ANSI 16.4 (CLASS 125) ONLY. IF HUlMTBrTY AND TEWERATURE DITTERINT'LAL CAUSES CONDENSATICH ON THE EXPOSED DRY SPRINKLER, CONSXDER WRAPPING THE EXPOSED BARREL VITH INSULATIEN, FOAM INSUILATING TAPE OR E01"ALENT. SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATMN 13F CONDENSATE AROUND THE FRAME, WHICH COULD INHnUT OPERATION 13R CAUSE PREMATURE OPERATION SEE BEL13V FOR RECOMMENDED Wmajos. RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (STANDARD DH56 HSW DRY SPRINKLER SHOWN) HIN" EXPOSED CLEARANCE BARREL HOLE LENGTH �Sa AB13VD INSIDE FACE (HEATED AREA) PIPE DECKnTE FLASHING RASOO 14003210 (RECOMMENDED) 3. 1OLA. (PROTECTED AREA) I INSULATED FREEVER OR COOLER STRUCTURE OR EXTERIOR FRAMING MINIMUM EXPOSED BARREL LENGTH (SEE ABaM DRY SPRINKLER IN COLD AREA INSIDE FACE DRY SPRINKLER IN COLD AREA (HEATED AREA> mow SEAL VET PIPE (PRDTECTED AREA) Fig. 1 Technical Data: K Factor Temperature Maximum Sprinkler Thread Size Rating Ambient Temperature Identification Number — US]Metric — I Sprinkler 'WC Cover (SIN) 1550F 135OF 100OF (68-C) (57-C) (38-C) 1751F 1651F 1501F 5.6 80 ill RA1664 (79-C) (74-C) (66-C) 200OF 1651F 150OF (93-C) , (74-C) l (66-C) overage Area Maximum Coverage Flow Rate Pressure Area Width x Length gpm (Umin) psi (bar) ftxft(mx m) 28 x 8 (8,5 x 2,4) 23(87,1) 16.9(1,2) 28 x 10 (8,5 x 3) 28(106) 25(1,7) Approval Type: • Quick Response, Extended Coverage. • Approved for installation in accordance with NFPA 13 for light hazard occupancies. 'C"', : lll,,,� I'll , 11, . . . . . . . . . . . . . . . . . . . Fig. 2 - XL02 Wrench Fig. 3 - F3 Wrench *DuPont Registered Trademark Maintenance Model DH56 Quick Response Dry Sprinklers should be in- spected and the sprinkler system maintained in accordance with NFPA 25, Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming, Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Model DH56 Quick Response Extended Coverage Horizontal Sidewall Dry Sprinkler Specification Sprinklers shall be a [quick response — cULus Listed] ex- tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction with a special deflector capable of providing a discharge over a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long horizontal throw. Water seal assembly shall consist of a Teflon* coated Belleville spring washer. Installation shall permit sprin- kler deflectors to be positioned 4" (102mm) to 12" (305mm) below the ceiling. Sprinklers shall have a nominal K-factor of 5.6 (80), and 1" NPT thread. Sprinkler temperature rating shall be [155'F (68' C)] and [200'F (93'C)]. Rated working pressure shall be 250 psi (17.2 bar). Standard finish: [white] [chrome] [bronze][Special finish— specify]. Quick response extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For recessed EC horizontal sidewall sprinklers: Replace "horizontal sidewall" with "recessed horizontal sidewall." Add: (1) Recessed escutcheon assembly shall be a two-piece es- cutcheon of push -on and thread off design with 112" (13mm) adjustment. Standard finish shall be chrome, white and brass. Quick response recessed horizontal sidewall sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace "horizontal sidewall" with "concealed horizontal sidewall." Add: Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a 112" (13mm) cover plate adjust- ment. Cover plate temperature rating shall be 1350F (570C) for 155'F (680C) dry sprinkler and 165'F (74'C) for 200'F (930C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [white] [Custom Color— specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). 11 DH56 HSW DRY QDRNKLOR System lee OICFG-"A 1 1/2" [38.10immi Total Adjus..ment Ceiling C3 1 1/4" 4" [101.60mm] Min Escutcheon Adjustment 12" [304.80rn-ml Max. 1/4" [6.35mm:, Fscutcheon Adjustment 1" NPI . . ...... . ......... 1 15/16" L! - - ----- L53.18mn 2 1/8" Dia. Hole in Wall 1/4" F6.35mml Sprinkler Con Protrusion "A" Dimension . ............. . . . AdjUstrneril. Nominal Position Range I , /4" [-6,35rnrn] of Escutcheon 1 114 ['31.75mi-il A VAILABLE D/M. /f 2 " TO 48 " (5 IMAII TO 1219A,91.4) /N 11,14" (6)AW10) /NCRL'A1,IL__1VrS 3" Dio. P6.20mm] Note: The Sprinkler Can protrudes 1/4', when escutcheon is in nominal position. Escutcheon adjustment provides - '14 " (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Fig. 4 QH56 H.SW DRY SPPINKLER 1" 12-5.4mm] Total Adjustment i/2" L12.7,imi ESCLItChcon AdjUl 4" [101.60mrn] Min. III" (304.80mm] Max. 1 , /2" [12.7mml Escutcheon Adjustment f El 315 ystem Tee H 5 .18m,n] I" NPT S I ......... ... .......................... . ..... .. 2 13/64" 3-1/2 ' [55.88mm] . a M] [88.9m D, Escutcheon Dia. . . .......... _J_ 2 1/2" Dia . ....... I i [6,3.5rnm] : i" 1-1/4" (31.75mm.1 Nominal Hole in Wall -2 Protrusion -----Sprinkler Can �_,'A" Dimension EsCUtcheon Olbroosa Adjustment Nominal Position Range + 1/2" [+12.7rnm] of [.�scutcheon - 1/2" [-12.7mm] AVAILABLE ',4" DIM. IS 2" TO 48" ('51MY TO 121-91VIV) AIV 114" (6MM) INCREMENTS Note: The Sprinkler Can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment pro- vides - 112" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Fig. 5 5. Q �Y Q [DR:NKLER DH56 HSW R'.-C[-QSF L) C-1- I �Iq Esc u Lc h eo n 1 1/2" [38.1 mm] 4" [101.6mm]Min. System Tee Cup T 12" [304.8mm.]Mox. 1 " NPT . . ....... . 7/32" Dia. [8 1.8mm] 2 5/8" D, 'a. rZ [66.68mrl] Hole in Wall Nominal Position of Escutcheon 2 9/32" Dia. [57.94mr-ril 1/4" Dia. Escutcheon Adjustment A" Dimension 1/2" Dia. [12.7mm] Adjustment Range Escutcheon Adjustment ±1/4" "�Esc.tcheon 015FG05A 1/4" Dia. Adjustment A VA ILA RL E DIM /5- J - 12' TO 18 (8,9YU TO 1219MY) /A/ 114- " (6AXY) INCREIVEN TS Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. A =11 QH56 H"M CONCFAI F-D DRY SPR;NKi.-FR Hole ;n Wall C-11,19 ---ft I—NST trl 1, 12' Ir Ul I i VIC W 1 , '1112' N 01I.PW 1139691 Ad,�� 9 016rCO78 olw�kw.T 1W "Mls ME 11 111W.I.Ims (W.) Ad,.f—f VY, fill 11 A&�STWMI AVAILABLE 'A" DIM. /S J-112" TO 48" (,-O,,9MM TO 1219MM) //V 114" (61VIV11, INCREMENTS .... . . . ..... . . . . . . . .......... . . .................................... . ... — Fig. 7 6. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCT(ON FEMALE FEMALE PIPE PIPE THREAD THREA D INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE SHORTER LONGER INLET INLET MALE MALE PIPE PIPE n THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3 DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICA TION 0 16fgO8A sm 7. Ordering Information Specify: 1 . Sprinkler Type (select one): (a) Model DH56 Dry EC HSW (b) Model DH56 Dry EC HSW/HB (c) Model DH56 Dry Recessed EC HSW/FP (d) Model DH56 Dry Concealed EC HSW 2. Sprinkler Temperature Rafing. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. 5. Length: "A" Dimension (face of tee to face of ceiling or wall) in 1/4" (6mm) increments. Notes: 1 . The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately], 2. All platings and paintings are decorative and intended for interior use. UL Listing Category Sprinklers, Automatic and Open. Quick Response Sprinklers. Installation Wrench' Model XL02 Sprinkler Wrench (Recessed & Concealed) Model F3 Sprinkler Wrench Note: A leak tight 1" NPT sprinkler joint can be obtained with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not tighten sprinklers over maximum recommended torque, It may cause leakage or impairment of the sprinklers. Escutcheon Data: FP cup/escutcheon assembly - 112" (1 3mm) adjustment Finishes (1) Standard Finishes (1) Sprinkler Escutcheon Cover Plate White or Black Polyester (2) Brass (1) Chrome White White Bronze Chrome Special Application Finishes Sprinkler HSW/HSW H8 I Escutcheons Electroless Nickel PTFE(Teflon" )*(21 1 Eiectroiess Nickel PTFE (Teflon!L (1) Other colors and finishes are available. Consult factory for details, (1) cULus listed Corrosion Resistant (1) Not available for HB escutcheons. Note: Paint or an other coatings applied over the factory finish will void all approvals anywarranties. 16' [4.9m] Minimum Spacing 28' [8.5m] Maximum Spacing MODEL DH56 DRY SPRINKLER WALL 4" [100mm] min. From Ceiling 12" [305mm] max. From Ceiling 28' [8.5m] 10' [3m] 016FG09A Fig. 9 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers, A pipe wrench may also be used to install a dry sprinkler provided that it only interferes with the steel outer tube of the assembly (item #8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler removal at a later date. *DuPont Registered Trademark 8. MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULBINSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL ENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) oi6tglo 15J,'9 16 157fgl6 OF DEFLECTOR MAY VARY DEPENDIA.'r, ON MODEL Fig, 10 Reliable ... For Complete Protectior Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. * Automatic sprinklers 9 Flush automatic sprinklers * Recessed automatic sprinklers 9 Concealed automatic sprinklers e Adjustable automatic sprinklers 9 Dry automatic sprinklers 9 Intermediate level sprinklers 9 Open sprinklers e Spray nozzles * Alarm valves Retarding chambers Dry p i pe valves * Accelerators for dry pipe valves 9 Mechanical sprinkler alarms 9 Electrical sprinkler alarm switches * Water flow detectors e Deluge valves e Detector check valves * Check valves 9 Electrical system * Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards * Inspectors test connections 9 Sight drains o Ball drips and drum drips 9 Control valve seals e Air maintenance devices 9 Air compressors 9 Pressure gauges 9 Identification signs * Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled 19100k� = M -0 00) 431-1588 Sales Offices Paper maME MIM 00) 848-6051 Sales Fax Revision lines indicate updated or new data. n 43 (1:14) 829-2042 Corporate Offices .......,-Iiablesprinkler.com Internet Address EG. Printed in USA 02/15 P/N 9999970308 FIRE SPRINKLER VALVES ES-A-2000B Series 2000B A A M E S Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 1/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1/2" - 2" (15 - 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" - 1 " (115 - 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33'F - 140'F (0.5-C - 60-C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. Job Name Job Location Engineer — Approval — P't 2" 2000B HC (50mm) 1/4" 2000B (20mm) Series 2000B Double Check Valve Assemblies are designed to protect drinking water sup- plies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non -potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C51 0 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C51 0. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals E99B fl) a N C us Q P C us 1015 B64.5 3/4" - 2" (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LEV models not listed. Horizontal and vertical "flow up" approval on all sizes. Contractor Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications an Ames products previously or subsequently sold. amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 231/2" (594mm) SIZE (ON) i DIMENSIONS WEIGHV in. mm A in. MM in. B MM C in. MM F in. MM G in. MM H in. MM in. I MM lbs. kgs. 1/2 15 10 254 45/8 117 27/16 62 5 127 3 3/B 85 25/16 59 21/16 52 4.5 2 3/4 20 111/8 282 . 4 102 31/8 79 63/16 157 3'/16 87 2% 54 15A6 33 1 5 2.3 1 25 131/4 337 51/8 130 4 102 7112 191 3/B 85 11 IN 43 1 VA6 43 12 5.4 1114 32 16% 416 5 127 35/16 84 91/2 241 5 127 3 76 2 50 15 6.8 1112 40 161/4 425 4/8 124 31/2 89 91/4 248 513/16 148 31/8 79 211/16 68 15.86 7.2 2 50 191/2 495 6/4 159 4 102 131/8 340 6'/B 156 37/16 87 2 "/16 68 25.75 11.7 ,jtrainer soia separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi '12" (15MM) 83 12 -0 69 10 55 8 41 6 28 4 14 2 0. 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.52.3 3.0 mps Flow Rate kPa psi - I . ....... I w 152 22 U) 0 124 18 96 14 69 10 Q (" 41 6 14 2 kPa psi 96 14 m 83 12 U) o 69 10 55 8 41 6 28 4 0. 14 2 0 0 AP 0 5 10 15 28 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 75 15 fps 2: 3 4.6 Mps Flow Rate kPa psi 00 1 " (25MM) 110 16 A 0 83 12 69 10 55 8 41 6 28 4 14 2 0 5 10 15 20 25 30 35 40 45 50 55 9p AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 .15 fps 1.5 2.3 3.0 4.6 Flow Rate Mp ift AMES. FIRE&WATERWORKS A Watts Water Technologies Company 4 1/.11 P203- -1 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 9pM 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 75 10 15 fps 1.5 2:3 3.0 4.6 Mps Flow Rate 1 (40mm) kPa psi 83 12 0 69 (a 10 - 0 55 8 - (D 41 6 28 4 14 2 0 CL 0 ApO 110 120 gpm 10 20 30 40 50 60 70 80 90 100 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 2" (50MM) 83 12 A 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm n 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 Mps Flow Rate USA: Backflow Tel: (978) 689-6066 - Fax: (978) 975-8350 - ArnesFireWater.corn USA: Control Valves Tel: (713) 943-0688 - Fax: (713) 944-9445 - AniesFireWater.com Canada: Tel: (905) 332-4090 - Fax: (905) 332-7068 - AryiesFireWater.ca Latin America: Tel: (52) 81-1001-8600 - Fax: (52) 81-8000-7091 - ArnesFireWater.corn ES-A-2000B 1410 0 2014 Ames Fire & Waterworks PIPE AND FITTINGS Product Specifications Harvel'�'BlazemasterO CPVC Fire Sprinkler Pipe Application: Corrosion resistant fire sprinkler pipe, IPS sizes 3/4" through 3", for use in wet automatic fire sprinkler systems. When installed in accordance with Harvel's Installation Instructions, this pipe is Listed by Underwriters Laboratories (UL) for use in: Light Hazard Occupancies as defined in the Standard for Installation of Sprinkler systems (NFPA 13); Residential Occupancies up to and including four stories in height (NFPA 13R); and Residential Occupancies as defined in the Standard for Sprinkler Systems in One and Wo Family Dwellings and Mobile Hornes (NFPAI 3D). Harvel BlazeMaster, pipe is UL Listed for use in Return Air Plenums (NFPA 90A), System Risers per NFPA 13 Light Hazard, 13R and 13D, Exposed installations, Garages per NFPA 13R, and for use as Underground Fire Service Mains (NFPA 24) when installed in accordance with Harvel CPVC Fire Sprinkler Pipe installation instructions. Scope: This specification outlines n-dnimum manufacturing requirements for Chlorinated Polyvinyl Chloride (CPVC) standard dimension ratio (,SDR) 13.5 series iron pipe size (IPS) fire sprinkler pressure pipe. Pipe is intended for use in wet automatic fire sprinkler sys� tems when installed in accordance with Harvel Plastics, Inc. CPVC Fire Sprinkler Piping Products Installation Instructions. f larvel, BlazeMaster, pipe carries a maximum working pressure of 175 psi @ 150 * E Pipe meets or exceeds applicable industry standards and requirements as set forth by the American Society for Testing and Materials (ASTM), the National Sanitation Foundation (NSF), and Underwriters Laboratories (UL). Harvel, BlazeMaster, fire sprinkler pipe is approved by the Factory Mutual Corporation (FM) and the Loss Prevention Certification Board (LPCB). Refer to current approval guide and installation and design manual for installation limitations. CPVC Materials: The material used in the manufacture of the pipe shall be a rigid chlorinated polyvinyl chloride (CPVC) compound, lype IV Grade 1, with a Cell Classification of 23447 as defined in ASTM DI 784. The compound and the finished product shall be orange in color, and shall be approved by the National Sanitation Foundation (NSF) for use with potable water. Material used shall be domestically produced BlazeMaster, CPVC material as provided by Noveon, Inc. (formerly the BFGoodrich Company). System Design: The CPVC sprinkler system shall be hydraulically calculated using a Hazen -Williams C 6ctor of 150, and shall be designed in strict accordance with the Standard for installation of Sprinkler Systems, NFPA 13 Light Hazard, NFPA 13R, and NFPA 13D as applicable. Dimensions.- /7\ HARVEF %111.� I larvel Blazelvlaster, CPVC fire sprinkler pipe shall be manufactured to Standard Dimension Ratio (SDR) 13.5 dimensions in strict accordance to the requirements of ASTM F442 for physical dimensions and tolerances, Each production run of pipe manufactured in compliance to this standard, shall also meet the test requirements for materials, workmanship, burst pressure, flattening, and extrusion quality defined in ASTM F442. Furthermore, this pipe shall consistently rneet or exceed the physical perfbrmance test requirements of the appropriate approval/listing agency(s) follow-up procedures established for the product. Marking: Product marking shali meet the requirements of ASTM F 442 and the Listing agency. Marking shall include: the phrase Harvel@ BlazeMaster* (or the manufacturers' trademark when privately labeled); the nominal pipe size; the type of material and material designation code; the SDR series and pressure rating for water (SDR 13.5; 175 psi @ 150*F); the ASTM designation F 442; the logo of the Listing and Approval agencies (UL, FM, LPCB, etc.); the independent laboratory's seal of approval for potable water usage (NSF-pw); the date and time of manufacture; and the UL assigned control number (2N95). Installation Procedures: All installation procedures such as storage and handling, solvent cement joining techniques, pipe support spacing, bracing, allowance for thermal expansion/contraction, component assembly techniques, and testing etc. shall be in strict accordance with Harvel Plastics, Inc. Installation Instructions and the UL Listing which includes installation limitations. System Components: Fittings used shall be UL Listed GPVC fittings and shall meet or exceed the requirements of ASTM F437 (Sch 80 threaded), ASTM F437 (Sch 80 socket), or ASTM F438 (Sch 40 socket) as applicable, such as those manufactured by Spears Manufacturing Co. or equivalent. Solvent cements used shall be those referenced in Harvel Plastics, Inc. Installation Instructions (such as Spears FS-5 or equivalent), which meet or exceed the requirements of ASTM F656 and ASTM F493, and shall be approved by the National Sanitation Foundation (NSF) for use with potable water. Socket type joints, sizes 3/4" - X, shall be made up using the One -Step solvent cement joining method. The solvent cement joining method chosen shall be applied in strict accordance with the appropriate procedures as outlined in Harvel Plastics installation Instructions. Maintenance: Maintenance shall be in accordance with the Standard for Inspection, Testing and Maintenance of Water Based Sprinkler Systems as defined by NFPA 25. Harvel Plastics, Inc. - 300 Kuebler Rd., Easton, PA 18040-9290 Tel: 610.252.7355 -Fax: 610.253.4436 - www.harvel.com /ZN HARVEF Product Specifications Limitations: HarvelO BlazemasterO CPVC Fire Sprinkler Pipe 0 CPVC systems are intended fbr use at a maximum working pressure of 175 psi and ambient temperature of 150'F. * CPVC systems shall employ sprinkler heads having a maximum temperature rating of 225 * F or lower, regardless of type. CPVC products shall be installed in wet pipe systems only, Air or compressed gas shall never be used for pressure testing. CPVC sprinkler systems shall be hydrostatically tested for 2 hours at 200 psi, or 50 psi in excess of the maximum working pressure when the maximum working pressure exceeds 150 psi. Lines shall be slowly filled with water and the air bled from the highest and farthest sprinkler heads before test pressure is applied. Only Rflon@ tape or a thread sealant specifically approved for use with Harve10 CPVC Fire Sprinkler Products shall be used in making threaded connections. Where freeze protection is required, onlyglycerin based anti -freeze solutions shall be used and installed in accordance with NFPA 13. Do not use glycol base anti -freeze solutions or contaminated glycerin solutions. CPVC is not approved for use in combustible concealed spaces where sprinklers are required to protect these areas as defined by NFPA 13, unless certain specific application sprinklers are installed per their listing. Refer to Harvel's current Installation Instructions for additional information. Harvel CPVC Fire Sprinkler Pipe Dimensions SDR 133 (ASTM F442) Nominal Size (in.) Average O.D. Min. Wall Average I.D. Nom.Wt. Lbs./Ft. 3/4 1.050 0.078 0.874 0.168 1 1.315 0.097 1.101 0.262 1-1/4 1.660 0.123 1.394 0.418 1-1/2 1.900 0.141 1.598 0.548 2 2.375 0.176 2.003 0.859 2-1/2 2.875 0.213 2.423 1.257 3 3.500 0.259 2.950 1.867 Sample Specification: 9 CPVC sprinkler piping may be installed in a plenum space adjacent to, but not over, openings in the ceiling such as open ventilation grills, and require the use of schedule 80 fittings for use on 11/2" and larger pipe sizes. Refer to Installation Instructions for additional detail. Minimum protection when installed "concealed" shall consist of 3/8" gypsum wallboard or drywall, suspended membrane ceiling panels weighing not less than 35 pounds per square foot, or 1/2' plywood soffits. Minimum protection for NFPA 13R and 13D systems may consist of 1/2" plywood. Harvel, BlazeMaster, pipe is Listed for use in exposed applications with certain limitations. When installed without protection, "exposed" pipe is to be installed beneath smooth, flat, horizontal ceiling construction. Exposed categories include: standard coverage and residential pendent and sidewall sprinkler applications, light hazard extended coverage and residential sprinkler pendent and sidewall sprinkler applications, use in unfinished basements with exposed solid wood joists, light hazard upright quick response sprinklers, and system risers (in 13R & 13D occupancies). Refer to Harvel's installation instructions for specific sprinkler head terriperature ratings and spacing requirements. The product must be installed in strict accordance with NFPA 13, 13D, 13R and Harvel's current CPVC Fire Sprinkler Piping Products Installation Instructions (HFS-3). Harvel CPVC Fire Sprinkler Products must be installed in accordance with Harvel's current installation instructions (HF-,3). Refer to this document for current listing limitations and installation requirements. ASTM STANDARD D1784 MATERIAL CLASSIFICATION EQUIVALENTS: Cell Classification 23447 = CPVC 'lype IV Grade I = CPVC 4120 I N41, PIPE SIZES SHOWN ARE MANUFAGTURED IN STRICT COMPLIANCE WITH ASTM F442 q r ml� --'TAB =,d 1D We, W1 All GPVC fire sprinkler pipe shall be manufactured from aType IV, Grade I Chlorinated Polyvinyl Chloride (CPVC) compound with a Cell Classification of 23447 per ASTM D1784. Pipe shall be manufactured in strict compliance with ASTM F442 to SDR 13.5 dimensions, con- sistently meeting the Quality Assurance test requirements of this standard with regard to material, workmanship, burst pressure, flatten- ing, and extrusion quality. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, arid shall carry a rated working pressure of 175 psi Cq, 150'F. All CPVC fire sprinkler pipe shall be installed in accordance with Harvel Plastics, Inc.. CPVC Fire Sprinkler Piping Products installation Instructions. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in cor1junction with the Installation Instructions. All CPVC fire sprinkler pipe shall be manufactured in the USA by an ISO 9001 Gertifed manufacturer and shall be FM and LPCB approved. All CPVC fire sprin- kler pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from factory. This pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foundation (NSF) seal of approval for potable water applications. All CPVC fire sprinkler pipe shall be Harvels BlazeMaster<El pipe as manufactured by HARVELS PLASTICS, INC. Harvel Plastics. Inc. - 300 Kuebler Rd., Easton, PA 18040-9290 Tel: 610.252.7355 - Fax: 610.253.4436 - www.harvel.com ES FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS The information contained in this publication is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact SpearsP Technical Services Department [West Coast: (818) 364-1611—East Coast: (678) 985-12631. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems, PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance vvith SpearsO Manufacturing Company FllameGuar& CPVC Fire Sprinkler Piping Products Installation Instructions - FG-3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spearso Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — SpearsO Manufacturing Company recommends the use of Speare FS-5 One Step solvent cement for joining Spearso products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — SpearsO Manufacturing Company recommends the use of SpeaWl BLUE 75Tm Thread Sealant. This product has been tested by Spears"and the sealant manufacturer for compatibility with the SpearsO CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Speare TorqueSafe TM style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER, Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug is all that is needed to seal this special connection. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90' elbows, M = Outside diameter of socket/thread hub; t 1/16 inch, tees, crosses; ± 1/32 inch, N = Socket bottom to socket bottom; couplings; ± 1/16 inch. H = Intersection of center lines to face of fitting; 90* elbows tees, crosses; ± 1/32 inch. Q = Width of flats; ±1 /16 inch. J = Intersection of center lines to bottom of socket/thread; 45* elbows; ± 1/32 inch W = Height of cap; ± 1/16 inch. L = Overall length of fittings; ± 1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5 (ASTM F 442) Part Number Nominal Size Average O.D. Average I.D. AFprox. Weight Lbs.lFt. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) A81 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) .280 CP-012 1-1/4 (31.8) 1.660 (42.2) 1394 (35.6) .418 CP-015 1-1/2 (38.1) 1,900 (483) 1.598 (40,7) .550 CP-020 2 (%8) 2.375 (60.3) Z003 (50.9) 872 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.260 CP-030 1 3 (76.2) 3,500 (88.9) 2.950 (75.0) 1.900 SPEARS" MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El TEE Socket x Socket x Socket M-- — - — - LH L Part Number Size G H L M Approx. M (Lbs.) 4201-007 3/4 9A6 1-1/2 2-31/32 1-5A 6 .11 4201-010 1 13A6 1-13A6 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3)32 4-7132 2 .29 4201-015 1 -1 �2 1-5/32 2-9A 6 5-132 2-11/32 .54 4201-020 2 1-13/32 2-15A 6 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1 A 6 3-15A6 7-7/8 4-3A 6 3.02 REDUCING TEE Socket x Socket x Socket Hl �M M [f!172 Gl G I G 2 H �H2- - L Part Number Size G Gl G 2 H Hl H2 L M N2 Approx. Wt (Lbs.) 4201-102 MOM 3/4 25/32 3/4 1 -11 A 6 1-1 3A 6 I-11A6 3-3/8 1-5A6 1-21/32 1-5A 6 .13 4201-125 10/43/4 21/32 1 13A6 SIB 1-25/32 1-1 3A 6 1-5ib 3-13/32 1-17/32 1-5A 6 1-5A 6 .15 4201-126 10/41 3/4 1-7/8 1-3/32 1-27/32 2-31/32 1-31132 3-13A6 1-23/32 1-23/32 1-13/32 26 4201-131 1 xl x3/4 21/32 13A6 21132 1-25132 1-1 3A 6 1-25/32 3-9A 6 1-5/8 1 -5A 6 1-5/8 16 4201-157 1-1 /4xl x3/4 11A6 1-1/32 llA6 1-1 5A 6 2-1/32 1-1 3A 6 3-25/32 2-3/32 1-13/32 1-23/32 .32 4201-158 1-1 Axl A 27132 29/32 25/32 2-1 A 6 2-1/32 1-29132 3-1 5A 6 1-31/32 1-5/8 1-5/8 1 �24 4201-159 1-1,141 A -1 A 31/32 1 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11/32 2-3/32 2-3/32 1-23/32 .35 4201-167 1-1 Axl -1 /43/4 21 f32 1 21/32 1 -29J32 2 1-29/32 3-13A 6 1 2 1 -5A 6 2 .22 4201-168 1-1 Axl -1 Axl 13A6 31/32 13A6 2-1 A 6 2-3f32 2-lA6 4-118 1-31132 1-21/32 2 .24 4201-169 1-1 Axl -1 Axl -1 /2 1-1/8 15A 6 1-1/8 2-3A3 2-11132 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1 12A -1 /43/4 11A6 1 1/4 2-1 A 6 2 1-1 5A 6 4 2-5A 6 1-3/8 1 2-1 A 6 .41 4201-202 1-1 /20 -1 Axl 27/32 1-1/32 1 2-7/32 2-5/32 2-1 A 4-15/32 2-5A 6 MIN 1 2-1 A 6 .42 4201-210 1 -1 /2xl -1 /2x3/4 23J32 1 -1 A 6 23/32 2-3f32 2-1/32 2-M2 4-3A 6 2-5A6 1-3/8 2-5A 6 .37 4201-211 1 -1 /2xl -1 12xl 1 3A 6 1-3A 6 13A 6 2-3A 6 2-114 2-3A 6 4-3/B 2-11/32 1-23/32 2-11/32 .41 4201-212 1 -1 12xl -1 /2x] -1 A 1 1-1/8 1 2-3,B 2-11 M 2-3/8 4-13A6 2-11/32 2-3/32 2-11/32 .48 4201-213 1-1 /2xl -1 /W 1-5A 6 1 1-1/8 1-5A 6 2-11 A 6 2-21132 2-11 A 6 5-3/8 2-11/32 2-27/32 2-11/32 .72 MADE IN THE U.S.A. FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE (continued) S ocket x S ocket x S ocket M1 m M2 �Gi G ­H2� Part Number Size G G1 G2 H H1 H2 L M N2 Approx. Wt (Lbs.) 4201-248 2x2x3/4 11A6 1-13/32 11/16 2-7[32 2-7/16 2-7/32 4-7A6 2-27/32 1-3/8 2-27/32 .52 4201-249 2x2xi 27/32 1-7A6 27/32 2-11/32 2-9/16 2-11132 4-23132 2-7/8 1-3/4 2-7/8 .57 4201-250 WA-1/4 1 1-11/32 1 2-1 D32 2-19/32 2-17/32 5-3/32 2-27/32 2-3/32 2-27/32 .63 4201-251 AM -1 /2 1-7132 1-13/32 1-7/32 2-11 A 6 2-25/32 2-11 A 6 5-18 2-27f32 2-11/32 2-27/32 .85 4201-289 Z-lf2x2-112xl 29/32 25132 29/32 2-21132 1-29/32 2-21/32 5-5/16 3-1/2 1-23132 3-1/2 1.03 4201-290 2-11W-1/20 -1 /4 1-3/32 1-23/32 1-3/32 2-27/32 2-31/32 2-27/32 5-21/32 3-17/32 2-M2 3-17M 1.13 4201-291 2-1)2x2-1)2x1 -1 /2 1-3/16 1/2 1 1-3/16 2-1 5A 6 1-7/8 2-15A 6 5-7)8 3-15/32 2-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/32 1-5/8 1-13/32 3-3/16 3-1/8 3-3A 6 6-11/32 3-1/2 3-7/11 3-1/2 1.34 4201-335 3x3x] 7/8 1-1 5A 6 7/8 2-3/4 3-1 A 6 2-3A 5-15/32 4-3/16 1-23132 4-3A 6 1.26 4201-336' 3x3xl -1 A 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5A 6 6-5/8 4-1/8 2-7/8 4-1 /B 1.94 4201-337 3x3x1 -1 /2 1-02 2-1 A 6 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 1 2-3A3 4-3A 6 1.46 4201-338 3x3x2 1-7/16 1-1 3A 6 1 1-7/16 3-5/16 3-511 C, 3-5A 6 6-19132 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1 1-3/4 3-5/8 3-23)32 3-5/8 7-1/4 4-3/16 3-17/32 4-3/16 2.11 -Branch Outlet Sized with Bushing TorqueSafe TM SPRINKLER HEAD TEE Gasket Sealed Brass Mi Thread Insert Style Socketx Socketx G asketF IPT H1 Wilh E lastDrner Seal - U se NO Thread Sealant t TG1 M t --- M2 G --4--]-4—G 2 -*---H H 2 14 Part Number Size G G1 G 2 H H1 H2 L M K41 W Approx. M (Lbs.) 4202-101 G 3/4x3/4xl /2 IA6 1-3A6 7/16 1-7A6 1-7A 6 1-17132 2-29f32 1-3/8 1-3A3 1-3/8 .22 4202-124 G 10/41 /2 7AG 1-11/32 9/16 1-9A6 1-11A6 1-9/16 3-1/8 1-11A6 1-3/8 1-3/B .26 4202-130 G I x1 x1 /2 7A6 1-11/32 7/16 1-9/16 1 -11 A 6 1-9/16 3-1,8 1-23/32 1-3/8 1-23/32 .28 4202-166 G 1 -1 Axl -1 Axl /2 7/16 r 1-5/8 7A6 1-11/16 1-1 5A 6 1 -11 A 6 3-3/8 2-1116 1-3/8 2-1 A 6 .34 4202-209 G 1 -1120 -1 /2xl 12 1 �2 1-1 43A6 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1 .41 4202-247 G 2x2xl 12 1/2 12-1 A 6 1 �2 2 2-11/32 ? .54 Not intended to convey or dispense water for human consumption through drinking or cooking _.- 3 SPEARS' MANUFACTURING COMPANY P— FlameGuar&' CPVC FIRE S INKLER PIPING PRODUCTS SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x F ipt M1 t G17 H —f r�l M M2 1!7--1 G G2 H 2 L Part Number Size G G1 G2 H 111 H2 L M W IV2 Approx. M (Lbs.) 4202-101 3/43/41 /2 7116 1-5/32 7A6 1-7/16 1-17/32 1-7/16 2-29/32 1-3/8 1-7/32 1-M .27 4202-124 10/41 /2 7/16 1 -11 f32 9A 6 1-9A 6 1 -11 A 6 1-9A 6 3-1/8 1 -11 A 6 1-3/8 1-3/8 .26 4202-130 1 X1X1 12 7A6 1-7/32 7A6 1-9/16 1-25/32 1-9A 6 3-118 1-3/4 1-3/16 1-3/4 .26 4202-010 1X1X1 11A6 1-3/32 11/16 1-1 3A 6 1-29/32 1-1 3A 6 3-19/32 1-23/32 1-23/32 1-23/32 .37 4202-156 1 -1 Axl A )2 7A6 1-15132 9A 6 1 -11 A 6 2-1/32 1 -11 A 6 3-3/8 2-3/32 1-D32 1-3/4 .30 4202-166 1-1 Axl -1 Axl /2 7A6 1-112 7A6 1 -11 A 6 2-1A6 1 -11 A 6 3-13132 2-3/32 1-3A6 2-3/32 .32 4202-199 1 -1 12A -1 Ax1 /2 1/2 1-5/8 9A6 1-7/8 2-3A6 1-1 3A 6 3-11 A 6 2-5A 6 1-7/32 2-1 A 6 .37 4202-209 1-1 /2xl -1 /2x1 /2 1/2 1-23/32 1/2 1-7/8 2-3/32 1-7/8 3-3/4 1 2-5/16 1-17/32 1 2-5/16 .45 4202-237 2A -1 12A /2 1/2 1-7/8 17/32 2 2-7A 6 1-29/32 3-15A6 2-27/32 1-7/32 2-5A 6 .48 4202-247 2x2xl /2 1/2 1 1-31/32 1/2 2 2-3/B 2 4-182 2-27/32 1-17/32 2-27132 .58 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x S R F ipt G I F 7 h H M - g��H— - - 7H - MZ G G21 2 L I __ Part Number Size G G1 G2 H H1 H2 L M NAI W Approx. XM. O-bs.) 4202-101 S R 3/4x3/4xl /2 19/32 3/4 19/32 1-19/32 1-7A6 1-19/32 3-7/32 1-13/32 1-3A6 1-13/32 .16 4202-1 24SR I x3MA /2 7A6 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3A6 1-17/32 .19 4202-130SR W A /2 7A6 29/32 7A6 1-9/16 1 1-5/8 1-9/16 1 3-1 ib 1-23f32 1-3A6 1-23/32 .20 4202-01 OS R 1X1X1 21/32 3/4 21132 1-25132 1-5/8 1-25/32 3-19/32 1-23/32 1 -11 A 6 1-23132 .26 4202-1 56S R 1-1 /4xl A 12 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-1332 2-3/32 1-3A6 1-23/32 .26 4202-1 66S R 1-1 Axl -1 /4xl /2 7A6 1-1/8 7/16 1 -11 A 6 1-27/32 I-11A6 3-3/8 2-3/32 1-3A6 2-3/32 .26 4202-168SR 1-1 /41 -1 Axl 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7)32 2-3/32 1 -11 A 6 2-3/32 .34 4202-1 99S R 1 -1 12xl -1 Ax 1 )2 9/16 1-9/32 1 17/32 1-15A6 1 2 1-25/32 1 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1 -1 /2xl -1 /2xl /2 112 1-1/4 1/2 1-7J8 1-31132 1-7/8 3-3/4 2-11132 1-3A6 2-11/32 .35 4202-211 SR 1-1 /20 -1 /20 27/32 1-7/32 27/32 2-7/32 2-1 A 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 20 -1 /2xl /2 23/32 1 -9/16 3A 2-7/32 2-9132 1 -3/4 3-31/32 2-7,18 1-3A6 2-11/32 .45 4202-247SR 2x2xl /2 1/2 31/32 1/2 1 2 1-11A6 1 19/32 4 2-7/8 1-3A6 2-7/8 .48 4202-287SR 2-11W-1/20/2 17/32 1 1-3/4 1 17/32 1 2-9/32 1 2-1/2 1 2-9/32 1 4-19/32 1 3-112 1 1-7/32 3-1/2 .78 MADE IN THE U.S.A. FrSPEAJRS 0 !Ei I FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS TORQUESAFE"m SPRINKLER HEAD TEE Gasket Sealed Brass Thread Insert Style Socket x Gasket F I P I x Socket With E lastDmerSea I - U se N 0 T hread S ealant M1 M' G 1 I G 1 H1 M M2 G2 �—H H42 Part Number S�izz e G G1 G2 H H1 1 H2 1 L M W Ap prox. M (Lbs.) 4203-122 G lxl/2xl 1-13/32 1-19/32 1-27/32 1-3/4 3-11/32 1-5/8 1-5/8 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE Brass Thread Insert Style S ocket x F ipt x S ocket MI M G I *2 M M2 LG— 32 H 11 L 1 __ Part Numbei Size G G1 G2 H H1 H2 L M 1W W Approx. \At �Lbs. 4203-122 1 xI /2xI 23/32 3/4 1-1/4 1 1-5/8 1-5/8 1 1-15/16 1 3-1/2 1-23/32 1-23/32 1-3/16 Z Not intended to convey or dispense water for human consumpton through drinking or cooking SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style S ocket x S R F ipt x S ocket M mi I—'- kG1 11 F M M2 2 L — * G 2 I H �2 Part Number Size G G1 G2 H H1 H2 L M NQ2 Approx. VVL (Lbs.) 4203-122SR lxl/2xl 27/K 231,32 1 1-3/32 1-23/321 1-5/8 1 1-25f32 3-13/32 1-3/4 1-3/4 1-3A6 .21 5 SPEARSO MANUFACTURING COMPANY FlameGuardOCPVC FIRE SPRINKLER PIPING PRODUCTS 3 El STREET TEE S pigot x S ocket x S ocket KA PIPE I t OR Hl §. Gl G G2 H 2— L# Part Number Size G Gl G2 H Hl H2 L NM W Approx. VA. �Lbs.) 4244-007 3/4 13A6 27/32 27/32 1-1 M 6 1-7/B 1-7/8 3-5/B 1-13132 1-13132 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3A 6 1-3/4 1-3,14 .27 4244-012 1-1/4 1-1/4 1 1 2-746 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13A6 1-1/8 1-1/8 1 2-7/8 2-9A6 2-9A6 5-11/32 2-11/32 1 2-11/32 .56 4244-020 2 1-23/32 1-7A6 1-13132 1 3-1/4 2-15/16 2-15A 6 6-5/32 2-7/8 1 2-7,B .84 99 ELBOW Socket x Socket JG IF LH I I Part Number Size G H M Approx. WL (Lbs.) 4206-007 3/4 9A6 1-1/2 1-5A6 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 7/8 2-5/32 2 .21 4206-015 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .45 4206-025 2-1/2 1-5/8 3-7A 6 3-7A 6 1.17 1 4206-030 1 3 1 1-29/32 1 3-23/32 1 4-3A 6 1.80 SIDE OUTLET ELBOW S ocket x S ocket x S ocket M H Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27/32 1-1982 1-5A6 .09 4213-010 1 13A 6 1-7/8 1-5/8 .18 MADE IN THE U.S.A. --mom" FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING 0 ELBOW S Dcket x Socket GI— mi H I It i m Part Number Size G G1 H H1 M Approx. VVL �Lbs.) 4206-131 1 x3/4 25/32 11A6 1-25/32 1-25/32 1-19/32 1-516 ']1 TorqueSafe TM 9CY SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style S ocketx G asketF IPT With E lastomer S eal - U se IN 0 T hread S ealant —H1 G 1 — -*­j G r I '' f mi L Part Number Size G G1 H H1 m m Approx. VVL (Lbs.) 4207-101 G 3/4xl)2 M 6 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130 G 1xI/2 15/32 1-131,32 1-9A 6 1-M6 1-23132 1-3/B .23 4207-166 G 1-1/41/2 1 15/32 1 1-19132 1-1 5A 6 MIA6 1 2-3/32 1-3/8 1 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD 99 ELBOW Brass Thread Insert Style Socket x F ipt H I GI— G t mi m Part Number Size G G1 H H1 m Nm Approx. WL (Lbs.) 4207-101 3/4112 M6 1-5/32 1-23/32 1-17/32 1-13/32 1-17/32 .25 4207-130 1x1/2 15/32 1-5/8 1-946 1-11A6 1-23/32 1-17/32 .28 4207-131 1 x3/4 17/32 1-1/4 1-21/32 2 1-23/32 1-3/8 .25 4207-166 1-1/4x]/2 15/32 1-17/32 1-11A6 1-1 5A 6 2-3/32 1 1-17/32 .33 Not intended to convey or dispense water for human consumption through drinking or cooking 7 SPEARV MANUFACTURING COMPANY FlameGuard"' CPVC FIRE SPRINKLER PIPING PRODUCTS j SPRINKLER HEAD 9CY ELBOW Special Reinforced Plastic Thread Style Socket x S R F ipt G1- M1 H M Part Number Size G G1 H H1 M Approx. M (Lbs.) 4207-101SR 3/41 /2 11/32 13A 6 1-15/32 1-1/2 1-13/32 1-3A6 .14 4207-130SR 1x112 7A6 7/8 1-9A 6 1-5/8 1-23/32 1-318 .20 4207-131 SR 1 x3/4 1 1/2 1 7/8 1 1-5/B 1-9A 6 1 1-23/32 1 1-3/8 1 .16 4207-166SR 1-1 /41 /2 1 13/32 1 1-1/32 1 1-21/32 1-23/32 1 2-3/32 1 1-7/32 1 .19 99 STREET ELBOW Spigot x Socket G1- M1 H L9 f Part Number Size G G1 H H1 KM Approx. WL (Lbs.) 4209-007 3/4 29/32 19/32 1 -1 5A 6 1 -11 A 6 1 -1 3J32 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27/32 1-3/4 .21 4209-012 1-1/4 1-9A 6 27/32 2-13A 6 2-3/32 2-3/32 .32 4209-015 1-112 1 -15/32 1-M6 2-271.32 2-9A 6 2-11/32 .42 4209-020 2 1-23/32 1-3M 3-7/32 2-15A 6 2-27/32 .65 MADE IN THE U.S,A. FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS 22-1/Z ELBOW Socket x Socket 19 H M- Part Number Size H i M Approx. VVL (Lbs.) 4216-007 3/4 1-3A 6 7/32 1-13/32 '09 4216-010 1 1-3/8 9/32 1-25/32 14 4216-012 1-1/4 1-1/2 5A6 2-M2 .20 4216-015 I-V2 1-7A 6 13/32 1-3A3 '19 4216-020 2 1-7/8 3/8 2-27t32 .43 4216-030 3 2-3/8 1/2 4-5/32 1.00 22-11Z STREET ELBOW Spigot x Socket H VI-- H j PIPEO.D. Part Number Size H Hl i 11 NM Approx. \Ak. (Lbs.)_ 4242-007 3/4 1-1/4 1-1/2 1/4 112 1-3/8 .08 4242-010 1 1-7AG 1-11132 5A6 71,32 1-23/92 .14 4242-012 1-1/4 1-9A 6 1-202 17/32 11A6 2-IA6 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11132 2-11 M .28 4242-020 2 1-29/32 2-1/8 7B2 5/8 2-7�B .42 4242-025 2-1/2 2-1 /B 2-1/4 13/32 1 f2 3-1/2 .6B 4242-030 1 3 2-13/32 2-13/32 9A 6 17132 1 4-5132 '99 SPEARS� MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El 4S ELBOW S ocket x Socket H Part Number Size H i M Approx. WL (Lbs.) 4217-007 3/4 1-5A6 5A6 'I -5A 6 .07 4217-010 1 1-13/32 3/8 1-51B 'll 4217-012 1-1/4 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15132 2-11/32 .32 4217-020 2 2-118 21/32 2-7/B .48 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 1 3 1 2-29/32 1 29/32 1 4-02 1 1.17 1 46 STREET ELBOW Spigot x Socket t H j PIPE O.D. Part Number Size H Hl i 11 Approx. ft. (Lbs.) 4227-010 1 1-1/2 1-5A6 1/2 1/4 1-5A3 .10 4227-012 1-1/4 1-25/32 1-9A 6 9A6 11132 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11132 .29 1 4227-020 1 2 1 2-5116 1 1-1 5A 6 1 25/32 1 13/32 2-7/8 .44 MADE IN THE U.S.A. 10 M FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS CROSS S ocket x S ocket x S ocket x S ocket M G H Part Number Size G G 1 H Hl L Ll M Approx. M (Lbs.)_ 4220-007 3/4 5/B A 1-21/32 1-21/32 3-5A 6 3-5A 6 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-112 1 -1 f2 3 3 6 6 3 1.43 4220-025 2-1/2 1 -11 A 6 1 -11 A 6 3-7A 6 3-7A 6 6-7/8 6-7/8 3-17/32 2.16 4220-030 1 3 1 2-3/32 2-3/32 1 3-31/32 1 3-31/32 7-15A 6 7-15A 6 1 4-7A 6 3.37 REDUCING CROSS S ocket x S ocket x S ocket x S ocket t Hl M Ll G 1 G --A -=1 — H L ---I- Part Number Size G Gl H Hl L Ll M NM Approx. VA. (Lbs.) 4220-131 1 x3/4 23/32 5/8 1-5A3 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/43/4 I-lA6 23132 2-1 A 6 1-31132 4-3132 3-31/32 2-1 A 6 1-13[32 .35 4220-210 1-1/20/4 IIA6 1-5/32 2-M2 2-3A 6 4-3A 6 4-11132 2-3/8 1-13/32 .42 4220-248 2x3/4 11A6 1-7A6 2-7/32 2-7A6 4-13/32 4-7A 2-29/32 1-13/32 .56 4220-289 2-1/2xl 29/32 1-3/4 1 2-11 A 6 2-7M 5-11 t32 5-3/4 3-1 f2 1-3/4 .98 SPEARV MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS 3 COUPLING S ocket x Socket M Part Number Size L M N Approx. M (Lbs.) 4229-007 3/4 2-118 1-5/16 346 .05 4229-010 1 2-3A 6 1-5/8 3/32 '08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11/32 3/32 .22 4229-020 2 3-1/8 2-7/8 1/8 .33 4229-025 2-1 f2 3-11 A 6 3-15/32 3A6 A 4229-030 3 4 1 4-3A 6 1 1/4 .89 REDUCER COUPLING Socket x Socket M L Part Number Size L M N Approx. M �bs.) 4229-131 1 x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1 /4x3/4 2-19/32 2-3/32 1-5/B 11/32 .17 4229-16B 1-1 Axl 2-11 A 6 2-3/32 1-23132 5A 6 .18 4229-210 1-1 /2x3/4 2-13A 6 2-11132 1-13/32 15/32 .19 4229-211 1 -1 /2xl 2-7/8 2-11/32 1-15A6 3/8 .24 4229-212 1-1 f2xl -1 A 2-13A 6 2-1382 2-1 /B 5/32 .23 4229-248 2x3/4 3-3A 6 2-7/8 1-7A6 23/32 .32 4229-249 2xl 3-1/8 2-7/8 1-2132 1/2 .31 4229-250 2xl -1 A 3-3A 6 2-7/8 2-118 17/32 .33 4229-251 2xl -1 /2 MA 6 2-27132 2-11)32 9/32 .31 4229-291 2-1 /2xl -1 /2 1 3-23/32 3-15132 1 2-11/32 21)32 .51 4229-292 2-1 /2x2 1 3-21/32 3-1,2 1 2-7,8 13132 .52 MADE IN THE U.S.A. 12 F �10 ErE�imj FlameGuardgCPVC FIRE SPRINKLER PIPING PRODUCTS �) GROOVED COUPLING ADAPTER G roove x S ocket PIPE O.D. Part Number Size L KM N Approx. M. (Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 .72 4233-015 1-112 3-3/4 2-11/32 2-11/32 .83 4233-020 2 IM32 2-27/32 1 2-11/32 1.27 4233-025 2-1/2 4-3A 6 3-1 5f32= 2-7A6 2.02 4233-030 3 4-5A 6 4-1/8 1 1-7A6 2.76 FEIVALE ADAPTER Brass Thread Insert Style Socket x F ipt M L M1 L-.F N Part Number Size L M M N Approx. VYL (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5A 6 .23 4235-010 1 2-3A 6 1-3/4 1 -11 A 6 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1 � 6 11132 .36 4235-015 1-1/2 2-9A 6 2-3/8 2-7A6 11132 .47 4235-020 2 2-25132 2-27/32 3-3A 6 7A6 1,05 Not intended to convey or dispense water for human consumption through drinking or cooking 13 SPEARV MANUFACTURING COMPANY HANGERS AND SEISMIC BRACING le, - -IN" & -Fig, 184(Formerly Afcon Fig. 515) Double Offset Hanger and Restrainer .. . .... . .. .. ................ ... ..... . ............ Size Range: '/4" through I" Material: Carbon Steel Finish: Pre -Galvanized per ASTM A653 C@U8 Service: LWED • Hanger and surge restraint for horizontal CPVC piping when installed on the side of the supporting structure. • Listed with hardware provided on structural wood beams and composite - vl wood beams (1" minimum). For wood structures with less than 1" thickness, wood blocks may be placed on the backside of the wood structure. #14xl" fastener pro- vided must be fully engaged in the wood block. • May be installed with concrete, steel, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Installation: Slide CPVC pipe through the double offset hanger and restrainer. Secure the hanger to the supporting structure with the screws provided or with listed fasteners. Features: Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. Easily attaches to wood structure with #14 x I" hex washer head self -threading screw supplied with product. No pre -drilling required. Bottom of pipe is offset V/2" from the structure. Eliminates wooden spacer blocks Ordering: Specify CPVC pipe size, figure number and description. ----------- 0 C x2 B L GPVC Pipe Structure Fasteners x2 FIG. 184: DIMENSIONS (IN) * WEIGHT (LBS) CPVC Pipe Size A B 0C H L Max. Hanger Spacing (FT.) Approx. Weight/100 1/4 11/2 11/2 1/4 31/8 5/8 51/2 17 1 11/2 11/2 1/4 31/8 5'/8 6 17 PROJECT INFORMATION APPROVAL STAMP Project: E]Approved Address: E]Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.1 8 CPVC AAML. Fig* 187(Formerly Afcon Fig. 511) 7%vo Hole 900 Side Mount Strap Size Range: 3/4" through 2" Finish: Zinc Plated Steel (Hot -Dip Galvanized optional) Service: Hanger for CPVC pipe in the horizontal position on the bottom of structural wood beams and Steel 20 Ga. (min.) (Fig. A). Can be usedas a restrainer, only in Stee120 Ga. (min) (Fig. B). During installation, adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger, minimizing vertical pipe movement. Approvals: UL and ULC Listed. installation: . Snap hanger over pipe. Secure hanger to mounting surface with screws provided. Do not anchor tightly to mounting surface. PiDe must be allowed to move freelv th ughhan Steel applications require two (2) #14 x V hex washer head self -drilling TEK screws. Not Supplied. Part Number STD-0090. Features: lus Beveled edge design helps protect the CPVC pipe from any rough surface. Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. No pre-driking required. Ordering: Specify CPVC pipe size, figure number and description. Fig. A Fig. B FIG. 187: DIMENSIONS (IN) 9 WEIGHT (LBS) CPVC Pipe Size A B 0C E F Max. Hanger Spacing (FT.) Approx. Weight/100 (lbs) '/4 1 11/2 1/4 11/8 2/4 51/2 5 1 1 1/8 11/2 1/4 11/8 21 '/16 6 6 114 1 '/16 1 11/4 1 1/4 11/8 31/4 61/2 7 1 '/2 11/2 1 'A 1/4 11/8 31/2 7 8 2 1 '/4 2 1/1 1 11/8 3/8 8 9 PROJECT INFORMATION APPROVAL STAMP Project: []Approved Address: E]Approved as noted Contractor: [:] Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.1 8 Material: Carbon Steel le, n_1 ��! kd<5 � �' a 2"i ri I"N Finish: Pre -Galvanized per ASTM A653 Am- C us Service: Hanger and surge restraint for horizontal CPVC piping when installed on the top, bot- tom, and side of the supporting structure. Guide for vertical CPVC piping when installed on the side of the supporting structure. Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. Listed with hardware provided on structural wood beams and composite wood beams (1" minimum). Listed with steel (18ga minimum) with two (2) #141" or V4"xl" hex washer head self -drilling TEK screws. For wood structures with less than 1" thickness, wood blocks may be placed on the backside of the wood structure. #10xl" fastener provided must be fully engaged in the wood block. May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: Snap hanger over pipe. if needed, squeeze strap back around pipe. CPVC pipe must be allowed to slide freely through the Fig. 188R. Secure hanger to mounting surface with screws provided or with listed fasteners. Features: Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. Easily attaches to wood structure with #10 x 1" hex washer head self -threading screw supplied with product. No pre -drilling required. Bottom of pipe is offset 11/2" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer HangE Restra Installation - Backing Nut Hanger = I - at top fastener Restraint = 2 - on each fastener 3 & Per NFPA-13D and NFPA-13R ainer PROJECT INFORMATION Project: APPROVAL STAMP L_jApproved Address: []Approved as noted Contractor: E] Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 MISCELLANEOUS MATERIALS Bulletin 425 Rev. E CKJ :3 _r�' T\j Crl T (D M Reliable Riser - Residential 1 " (25mm), 11/2" (40mm), and 2" (50mm) sizes. For use in NFPA 13D and 13R Residential Systems Features: 1 . Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar). 5. Choice of trim: • Basic Trim (Fig. 1). • Basic Trim with Pressure Relief Kit (Fig. 2), • Basic Trim with Test and Drain Valve (Fig. 3). • Basic Trim with Test and Drain Valve and Pressure Relief Kit (Fig. 4). 6. Choice of mounting options: • Supply/ System lines support. • Support Bracket (to stud) (Figs. 5 & 6). • Recessed or Flush mount (to wood panel) (Fig. 7). 7. NPT (female x female) or tapered met- ric (female x female) connections. 8. Slim design allows for easy installation within 2" x 4" on 16" centers wood frame construction. 9. Dedicated cULus Listed and ULC Listed Wa- ter Flow Detector assures optimum sensitivity. Water Flow Detector is factory installed with a metallic, weatherproof cover. Triggeringflow rate is 4(15) GPM(LPM) to 10(38)GPM(LPM). Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and ULC Listed. 2. NYC MEA 258-93-E Fig. 1 Base Trim Fig. 2 Base Trim with Pressure Relief Kit rig, o mase i rim witri i es7t ano urain Valve Fly. �+ Odbt: I F1111 WIM I Mill. dFlU UFUll" Valve & Pressure Relief Kit Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Optional Trims - Technical Data: Description Basic Trim Basic Trim with Basic Trim with Test Basic Trim with Test and Drain Valve Take Out Pressure Relief Kit and Drain Valve & Pressure Relief Kit Dimension Dimensions Weight* Dimensions Weight* Dimensions Weight* Dimensions Weight* Manifold Size: A inch B inch Lbs A inch B inch Lbs A inch B inch Lbs A inch B inch Lbs C inch (MM) (MM) (kgs) (MM) (MM) (kgs) (Mirn) (MM) (kgs) (MM) (MM) (kgs) (MM) 11 8-3/4 7.3 131/2 11 8.7 11 141/4 9.0 15 141/4 10.6 81/4 (25mm) (279) (222) 1 (3.32) (343) (279) (3.95) (279) (362) (4,09) (381) (362) (4.82) (210) 11/211 11 91/4 8.3 131/2 11112 10.5 11 143/4 9.7 15 143/4 11.2 81/4 (40MM) 4UM (279) (235) (3.77) 1 (343) (292) (4.77) (279) (375) (4.41) (381) (375) (5.09) (210) 2"M 11 93/4 8.8 I 131/;-, 12 1, 81/4 0MM) Omm) 5 5: (279) (248) (4 nn) (.q4.q (210) Support Bracket Kit (optional) - 1 lb (0.45 kg) All Reliable Risers have a 1" NPT drain port. Bas*c Trim wqth Pressure Relief Kit Basic Trim With Test and Drain Pressure Relief Ki Water Water _\ Press, Relief Gauge Kit (Opt Press re 13- Kit (Opt. Pressure B Gaug ----Press. Relief Manifold System Manifold System Body Support Body Support Bracket Bracket 2- 0 0 A A c c (Take -Out) (Take -Out) so + 16 2, Supply supply Drain in Valve \—Test and Drain Valve Water Flow Detector Water Flow Detector Drain (Contact Ratings: 10A @ 125/250 VAC 2.5A @ 24 VDC) (Contact Ratings: IDA @ 1251250 VAC 2.5A @ 24 VDC) 425FG05 Fig. 5 Product Description: The Reliable -Risers come factory assembled with all of the necessary accessories for a cost effective, yet com- plete riser solution. Reliable -Risers are [UL Listed][ULC Listed] [NYC Ap- proved MEA 258-93-E] for horizontal or vertical installa- tions as a one-piece, factory assembled unit for use in NFPA 13D and 13R residential systems. The riser mani- fold assembly shall consist of a (choose one): 0 1" (25 mm) cast, non -welded stainless steel body with 1" female NPTor IS07-Rcl-11 threaded end connec- tions. 0 1112" (40 mm) cast, non -welded stainless steel body with 11/;>" female NPT or IS07-Rcl.5-11 threaded end connections. 9 2" (50 mm) cast, non -welded, stainless steel body with 2" female NPT or IS07-Rc2-11 threaded end connec- tions. All of these manifold sizes have cast -on lettering that clearly identifies the manifold's pipe size, flow direction, UL Listing/ ULC Listing, and the test and drain outlet. A built-in drain port is included to permit hydrostatic testing without draining the system. The assembly has a work- 2. ing pressure rating of 175 psi (12.1 bar). Cast -in mount- ing holes are provided for recessed or flush mounting to a wall. For stud mounting, a support bracket is available that is specifically designed for the cast mounting holes. All of the trim variations include brass components, a cULus Listed 300 psi water pressure gauge, and a 250 psi UL Listed/ ULC Listed Waterflow Detector. This Water - flow Detector comes factory installed with a weatherproof (outside) cover. Trim Descriptions Basic Trim Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPIDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Basic Trim with Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPIDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure relief valve kit shall be provided to maintain system pressures below 175 psi (12.1 bar). Basic Trim with Test and Drain Valve Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector contain- ing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the Test and Drain assembly shall be** **(Choose one) * 3/8" (10 mm) * 7/16" (11 mm) 0 112" (15 mm) Basic Trim with Test and Drain Valve & Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPIDT (Form C) contacts, having an elec- trical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure Relief Kit shall be provided to maintain system pressures below 175 psi (12,1 bar). Installation: 1 . Install the manifold with the flow arrow pointing to- wards SYSTEM side using threaded connections. 2. Connect a 1" NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non -fire protection connection (permitting continual water flow) require di- electric fittings, according to NFPA 13 sect, 4-6, when dissimilar metal piping materials are joined. Note: Use a non -hardening pipe joint compound, or tape. 5) . . . . ........... ..................... ................. ... ....... J. 4­­ ......... . .......... . .................... .... . ...... . .............. RAD 9M. WOOD PAINEL PIASTIC SPArEWS - - - - - - - - - - - - - - -- - - - - - 7 -1- R1 HU PECESFO� OR R USH A1,06INT67; Fig. 7 0 Ordering Information: Residential Riser Part Number Code Key im 1.5N 1.5M 2N 2M 1 N 1 " (25mm) APT Threaded Ends Assembly 1 M 1 " (25mm) Metric Threaded Ends Assembly 1,5N 1-1/2"(40mm) NPT Threaded Ends Assembly 15M 1-1/2" (40mm) Metric Threaded Ends Assembly 2N 2" (50mm) NPT Threaded Ends Assembly 2M 2" (50mm) Metric Threaded Ends Assembly T38 T716 T12 B = Basic Trim Assembly T38 = Basic Trim Assembly with 3/8" (10mm) Orif. Test and Drain Valve 716 = Basic Trim Assembly with 7/16" (11 mrr Orif. Test and Drain Valve T1 2 = Basic Trim Assembly with 1/2" (11 5mm) Orif. Test and Drain Valve 1 2 3 0 = Assembly without Pressure Relief Kit Water Detector - UL & FM Approved 1 = Assembly with Pressure Relief Kit Water Detector - UL & FM Approved 2 = Assembly without Pressure Relief Kit Water Flow Detector - ULC Approved 3 = Assembly with Pressure Relief Kit Water Flow Detector - ULC Approved Example #1: 1.5N - B - 1 (1-1/2" (40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pres- sure Relief Kit). Example #2: 2M — T1 2 — 0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with Test and Drain Valve having a 112' Diameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit (For Basic Trim) 98020076 Pressure Relief Kit (For Basic Trim with Test and Drain Valve 6501203551 Support Bracket Kit 6899190001 Waterflow Detector (RFDTHN) 96556910 Waterflow Detector ULC (RFDTHANA) 96556914 Paddle Tree - Waterflow Detector 96556911 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries, Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data, EG, Printed in U.S.A. 12/15 P/N 9999970348 (E)POTTER The Symbol of Protection, US Patent No. 6,945,509 RBVS UNIVERSAL BALL VALVE SWITCH UL and cUL Listed, FM, CSFM Approved Dimensions: (including mounting clamps) Large Clamps: 6" L x 5" W x 5.2" H 15,2 cm L x t2,7 cm W x 13,,2 cm H Small Clamps: 6" L x 4" W x 5.2" H 15,2 cm L x 10,2 cm W x 13,2 cm I I Weight: With Large Clamps: 13.6 oz. (386,9 g.) With Small Clamps: 11.0 oz. (311,2 g.) Enclosure: Non -Corrosive Composite Material Environmental Limitations: - NEMA 4 rated enclosure when proper electrical fittings are used. (IP67) Temperature range: -40'F to 150'F (-40'C to 65'C) Not for use in hazardous locations Housing CoverTamper: Activated by housing cover removal (Stock No. 1000035 only) Contact Ratings: RBVS Stock No. 1000040 (w/o Cover Tamper) SPDT Contacts: I OA at 125/250 VAC R.Bvs-'r Stock No. 1000035 (w/Cover Tamper) 2A at 30 VDC Optional Cover Tamper Kit Stock No. 0090201 SPI]ITCover'Famper: 3Aat250VAC General TheModcIRBVS is designed to monitor the fully open position of a ball Valve installed in a sprinkler system. The unit will fit oil most ball valves installed on back-flow-preventers and alarm trim lines of dry, alarm, and deluge sprinkler valves. The switch operates if the ball valve handle is moved from the open position. However. the switch does not track- the position of the handle or ball. When the ball valve handle is in the open position, a spring -loaded switch button "I contact the valve handle. When the handle is moved from the open position, this switch button extends to the tripped position, and die RBVS contacts change state, thereby opening or closing a circuit. A cover tamper switch is avai lable and is activated by the removal of the RBVS housing cover. If an attempt is made to remove the RBVS by the removal of the mounting brackets, the unit wil I be set into the tripped mode by this action. The RBVS can be mounted to the hex portion of the ball valve or back-flow- preventeror to the adjoining pipe via two clamps. TheRBVS is shippedwith two sets of mounting clamps to accommodate various pipe and valve sizes, refer to Table 1. An "U shaped and offset bracket for mounting the switch enclosure kind an extension bracket add to the mounting flexibUity of the RBVS. See "'lypical Mounting Diagrunt" and "Installation and Operation" on following page. 'resting The RBVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority havin.-jurisdiction (manufacturer recontmends quarterly or more ftcquently). Fig.1 Internal Components NORMALLY OPEN � NORMALLY CLOSED COMMON SWITCH BUTTON STRAIN RELIEF D LOCATION ON HANDLE BLACK - N.O. COVER RED - N C. TAMPER WHITE - CO'M MOUNT SO SWITCH BUTTON IS APPROX. I" FROM PLASTIC COATING Carefully route tamper switch vvires through strain relief channel in switch HANDLE INSIDE END REMOVED FROM I BALL VALVE HANDLE ure. FU ly seat die, %Yurs Into die Rom of uie Channel. 3ee rig. I. IN SWITCH BUTTON 17. Replace RBVS switch enclosure cover and securely tighten cover screw. OWG #1086-1 CONTACT AREA Installation On Lever Handle (See Fig. 2) 1. Select clamps and clamping bolts based upon pipe/valve size. see Table 1. 2. Insert rubber clamp grippers into clamps, see Fig. 2. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts, but do not fully tighten, (be sure hex nuts seatproperly in clamp hex recesses). (NOTE: Some installations may require one of the mounting bolts to be inserted from the bottom of the brackets and then trimmed to allow the extension bracket to clear. See Fig. 4) 5. Attach extension bracket (if necessary to use for positioning) to top clamp using V4-20 X I/V Hex bolt and -washer, but do not fully tighten. 6. Attach "L" bracket (RBVS switch enclosure is loosely attached to "L" bracket) to extension bracket using '/4-20 X 1/4" 1 lex bolt and washer, but do not fully tighten. 7. Be sure ball valve is in the fully open position. 8. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately I " from its inside end. See Fig. I for approximate location. Cut and remove the plastic coating from the ball valve handle to allow die RBVS switch button to contact (and be activated by) the metal of the handle. 9. Tighten clamping screws alternately to an eventual 30 in-lbs. (minimum) of torque. 10. Maintain position of switch enclosure over valve handle and secure bolt that holds the extension bracket to the clamping assembly. It may be necessary to close valve to access this bolt. 11. Position '12'bracket so that it contacts the back edge of the valve handle, and secure its bolt. It may be necessary to close valve to access this bolt. 12. With the actuator fully retracted, position RBVS switch enclosure to contact the valve handle squarely. see Fig. 1. 13. With RBVS switch enclosure held squarely in contact with valve handle, securely tighten the two tamper resistant screws oil the backside of the enclosure. 14. Close and open the valve to verify operation.The actuator should easily retract when the valve handle is in the open position. 15. Fully open the valve. 16. Remove the cover and wire main switch and tamper switch if applicable. Potter Electric Signal Company, LLC - St. Louis, MO - Phone: 866-956-0988/Canada 888-882-1833 - www.pottersignal.com PRINTED IN USA WG.4 5401086 - REV V PAGE 1 OF 2 5/09 ANPF�a& UP POTTER 6 The Symbol of Protection Fig. 2 Typical Mounting Diagram DWG #1086-2 Typical Electrical Connections LOCAL CIRCUIT TRANSFORM ER OR BATTERY POWER N.C. ,C,�...U.G DEVICE WITCH NCLOSURE -" BRACKET J, BRACKET NECESSARY) CLAMPS CLAMP GRIPPERS 7 HEIG IJ T 5.2 :3 1 -L,--,-J- I WIDTH 4" (SMALL) 5" (LARGE) RBVS UNIVERSAL BALL VALVE SWITCH Table I Clamp Sizing Pipe Valve/Size Clamp I Clamping Bolts 1/211 to 3/411 (12,5 to 19mm) Small 10-32 x 2 1/2 I" to 2" (25 to 50mm) Large F 1/4-20 x 4" Switch Terminal Connections, Clamping Plate Terminal "C' D%U# W3-3 STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT TO N,C. CONTROL COM, . END-OF-UNE RESISTOR N 0 V- NO UNIT .0. --N� �'N C DWG. #10BS-4 Tamper Switch Connections COVER TAMPER & RBVS CONNECTED COVER TAMPER & REVS WIRED TO THE SAME ZONE ON THE FACP TO SEPERATE ZONES COVER TMPER COM. N.O. COM. COM5" N.O. COM. FACP rACP FACP N .01 EOUR DWG. #1086-5 Installation on Tee Handle (See Fig. 3) 1 . Select clamps and clamping bolts based upon pipeivalve size, see Table 1 2. Insert rubber clamp grippers into clamps, See Fig. 3. 3. Place one clamp on top of pipe/ball valve near the valve handle and insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation and thread hex nuts onto the clamping bolts. but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to the RBVS housing. 6. Be sure ball valve is in the fully open position. 7. Slide loosely assembled RBVS switch enclosure to a position that permits the switch button to contact the valve handle approximately 1/2" from the end of the handle. Cut and remove the plastic coating from the ball valve handle to allow the RBVS switch button to contact (and be activated by) the metal of the handle. 8. Tighten clamping screws alternately and IA-20 X 1/41' boltto 30 in-lbs. (minimum) of torque. 9. With the valve handle fully open, slide the RBVS housing down until the switch operates plus 1/8 inch. Tighten the screws holding the RBVS to the "offset" bracket. 10. Remove the RBVS switch enclosure cover. 11. Close and open the valve to verify operation. The actuator should easily retract up when the valve handle is in the open position. 12. Fully open the valve. 13. Wire main switch and tamper switch (if applicable). Carefully route tamperswitch wiresthrough strain reliefchannel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. 14. Replace RBVS switch enclosure cover and securely tighten cover screw. Fig. 3 Fig. 4 I A CAUTION I An uninsulated section of'single conductor should not be looped around the terminal and serve as two seperate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged ftom under the terminal. M�Mlo "" —*--11 [ �--Pvq'�W—rm— I SOME fNSTALLAT1ONS MAY CAUSE INTERFERENCE BETWEEN MOUNTING BOLT AND OFFSET BRACKET. INSTALL BOLT FROM BOTTOM AND TRIM AS NEEDED TO COR-R.ECT. DWG4 1096-6 D.0 #1086-3 PIPE PRINTED IN USA MFG�g 5401086 - REV V PAGE 2 OF 2 5/09 HYDRAULIC CALCULATIONS J- WATER AVAILABILITY CERTIFICATE 1 .11 V , I j 1) PERMITTING & DEVELOPMENT ENGINEERING D I V I S 10 N 12:1 5th Avenue N P: 425-771.0220 www.edrnondswa.aov ITEMS IN THIS BOX TO BE FILLED IN BY APPLICANT X Building Permit 11 Preliminary Plat or PUD 0 Subdivision 0 Rezone or Other Applicant's name: Mark Cummings Proposed Use: 4 Unit Apartment Development Location (attach map and legal description if necessary): 20904 7:Znd Ave W Updated on 811412018 Page I qf 2 Permit Number BLD 2017:L835 Pro - ject Name Cummings Development LLC INFORMATION PROVIDED BY WATER AGENCY 1. Z a. Water will be provided by service connection only to an existing 8 inch (size) water mainthatis ad*acent fromthesite. OR EJ b. Water service will require an improvement to the water system of: 13(l). feet of water main to reach the site; and/or 0 (2). The construction of a distribution system on the site; and/or 0 (3). Other (describe): 2. Z a. The water system is in conformance with a City approved water comprehensive plan. OR 0 b. The water system improvement will require a water comprehensive plan amendment. (This will cause a delay in permit issuance and approval.) 1 9 a. The proposed project is within the corporate limits of the City, or has been granted Boundary Review board approval for extension of service outside the City, or is within the City approved service area of a private water purveyor. OR 0 b. Annexation or Boundary Review Board approval will be necessary to provide service. 4. 9 a. Water is/or will be available at the rate of flow and duration indicated below at no less —than 20 Psi Measured at the nearest fire hydrant — feet from the building/property (or as marked on attached map) Rate of Flow Duration 0 Less than Soo gpm. (approximately —gpm) 0 Less than one (i) hour 0 500 to 999 gpm 0 One (1) to two (2) hours 0 1500 gPm or more Two (2) hours or more 0 0< Flowtestof . q . P.M 0 Other Calculation of Zy re 30 —9pm (Commercial building permits require flow test or calculation) OR El b. Waterwill system is not capable of providing fire flow. WATER AGENCYCERTIFICATION COMMENTS/CONDITIONS: Per Model, Static Pressure. is 72.q p5i at:ijopo cipm, residual Rressure is 69.4 psi at rnaX flOW.Of 2,6309pm residual pressure is 49.:L psi I hereby certify that the above water purveyor information is true. This certification shall be valid for one year from date of signature. --� i Eetv'4-4J.5- (Agency Name) Signatory Printed Name (Title) (Signature/Date) f Updated on 811412018 Page 2 of 2 Hydraulic Overview Job Number: CASCA18-2002 Renort DeSCriDtion- Residential Job kb N—lbe, Des4n Engimer CASCAl B-2002 Job N­ Edmonds Multi -Unit Phorre Address I 20904 72nd Avenue W State CertificatJoWl-lo-m Nmoor CASCAFP833L2 Addreas 2 Edmonds, WA 98026 AHJ City of Edmonds Add- 3 Job She/Strioarg Unit 201 System D—Ity A- of APPHoetao. 0.050gpM/ft2 236.00ft2 (Actual 374.85ft2) Most De­dft Sp6W. Data Hose Stmarre 4.9 K-Factor 12.96 at 7.000 100.00 Cmerage Per Spit ftr Nu;ber Of SprlrAc*m C&Wa*d 256 .00ft2 Sy— Pae— N—. StMea Fl- D—M 57.698 55.47 Total Demnd 155.47 @ 57.698 Presstire Rml +14.179 (19.7%) Supplies Check Point Gauges Node Name Flow(mm) Hose Flow(cipm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(npm) 100 Water Supply 2630.00 100.00 72.000 49.000 "'""""aa-ee-reatelareellearee-alarea, WASHINGTON STATE CERTIFICATE OF C40UPIPTEMCV FIRE PROTECTION BPRINKLER SYSTEMS Lud.Ac. C. Que,ol 1605-0294-C Level 3 Cascadia Fire Protection, LLC CASCAFP8331_2 Ludovice Qumr 8-27-18 a pwas a Date Q1 Ima 3395 Water Supply at Node 100 (2630.00, 100.00, 72.000, 49.000) 10 90 80 Static Pressure 72.000 7 1 1 1 i INL I .0 60 47 CL 1 1 963 .00 @ 49.000� 50 to cu 40 : System demand curve 3 20 10 K 0 ... 'It 4000 00%OP002500 3000 5000 3500 4500 Water flow, gpm & 0 M. E. P. CAD, I nc. rjjj AutoSPRINKG 12 02.0.61.0 Page 1 ��I§Hydraulic Summary Job Number: CASCA18-2002 P. ­t P­itq­fi.I Job Job Number De"n EnVareer CASCA18-2002 Job Name: State C1'VftJn/t.1.— N—br Edmonds Multi -Unit CASCAFP8331_2 Address I 20904 72nd Avenue W AKJ1 City of Edmonds Add— 2 Job SKetBufloing Edmonds, WA 98026 Unit 201 Add— 3 Dravring Name 3395 System RemoteArea(s) M.11 DernindIng Sprin)JI, Data O=pamoy Job Stift 4.9 K-Factor 12.96 at 7.000 Residential How Alto— At Souroe D ... Ity Aa� of A - Katti- 100.00 0.050gpMlft2 36. 60ft2 (Actual 374.85ft-) Addflionsl How SuppUn Number Of Spdnlftm CaWaled C-96 Per Spd T Node Flow(qpm) 4 256.00ft' AutoPeak ReWW Premm For Remrta Aaaa(*)AqaoenI To Nora Remote Area Right: 52.280 Total How Sim... 100.00 System FW Daaaamd —1 -1.1 Ile,11- (hdWhV How Allomnoe) 55.47. 155.47 W�m PfawlrO Unbolmoe, In Loop 0.000 Max[mm Veloofty Abfte Gnmmd 18.69 between nodes 108 and 107 WxImum Velocity Unfet Ground 5.90 between nodes 100 and 99 VbW_.p.oftYo1~pip`w Vo*,m. ­KY.1 Cry po'. 46.13gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin @ Node Name (gpm) (psi) psi) (Qpm) (psi) (Qpm) I (psi) (psi) 100 Water Supply , 100.00 72.000 49.000 2610 On 71.877 155.47 57.698 14.179 Contractor Co—ct,r 1-1,r CASCAFP8331_2 C.rtot Name David Sherepitka Od Title Cascadia Fire Protection Phone 253-202-3909 EA ... 1. Addrans I 12911 120th Avenue E FAX Addra. 2 Puyallup, WA 98374 E­11 david@cascadiafirepro.com Adore. 3 '*""' M. E. P. CAD, I nc. �,TAAutoSPRINKO 12 02.0.61.0 Page 2 Job Number: CASCA18-2002 Report Description: Residential Device Actual Flow (Apm) Minimum Flow (qpm) K-Factor Pressure (psi) Sprinkler 11011 12.96 12.80 4.9 7.000 Sprinkler 102 13.10 12.80 4.9 7.148 Sprinkler 104 13.64 12.80 4.9 7.743 Sprinkler 106 15.77 12.80 4.9 10.359 Most Demanding Sprinkler Data & (D M.E.P.CAD, Inc. 45 AutoSPRINKO 12 02.0.611.0 Page 3 F, Job Number: CASCA18-2002 Ppnnrt npzrrintinn- PpQirlpnfini Node i Elevation(Foot) Fiffinas Pressure(ps!) Discharge (qpm) 100 01-0 s 57.698 55.47 101 18'-0 Spr(-7.000) 7.000 12.96 102 18'-0 Spr(-7.148) 7.148 13.10 104 18'-0 Spr(-7.743) 7.743 13.64 106 18'-0 Spr(-10.359) 10.359 15.77 99 4'-0 BFP(-1 .911) 48.697 103 18'-6 T(5'-O), Tr(l'-O) 7.546 105 18'-6 T(5'-O), Tr(l'-O) 8.046 107 18'-6 C(5'-O), Tr(l--O) 10.646 108 18'-6 T(5--O) 16.271 CM, 0 M.E.P.CAD, Inc. 'I ,a AutoSPRINKO 12 vl 2.0.61.0 Page 4 Y W Job Number: CASCA18-2002 Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K -Factor Pt Pn Fittings JEq L ngth Total Length Summary 4i* ..... Route I ..... DR 1.1010 12.96 4.37 150 0.030510 10'-0 Pf 0.763 101 103 181-0 18'-6 12.96 4.9 7.000 7.546 Sprinkler, 2E(T-0), Tr(1'-0) 15'-0 26-0 Pe Pv -0.217 BIL lA010 26.07 8.78 150 0.111064 T-6 Pf 0.500 103 105 18'-6 18'_6 13.10 7.546 8.046 Flow (q) from Route 2 Tr(i '-0) V-0 4'-6 Pe Pv BL 1.1010 39�70 13.38 150 0.241898 9'-9 Pf 2.600 105 107 18'-6 18'-6 13.64 8.046 10.646 Flow (q) from Route 3 Tr(1'-0) V-0 10'-9 Pe PV BL 1.1010 55.47 18.69 150 0.449144 T-6% Pf 5.625 107 108 181-6 18'-6 15.77 10.646 16.271 Flow (q) from Route 4 T(5'-O) 6-0 12'-6% Pe Pv CM 1.3940 55.47 11.66 150 0.142341 56-11% Pf 26.140 108 99 18'-6 4'-0 16.271 48.697 3Tr(l'-O), T(6'-O), 5E(8'-O), cp1g(1'-0), BFP(-10.911) 50'-0 106'-11% Pe Pv 6.286 1.9590 55.47 5.90 150 0.027145 76'-6 Pf 7.267 _UG 99 100 4'-0 01-0 48.697 57.698 2E(3 . -6), VVMV(-5.000), S T-0 83'-6 Pe Pv 1.734 100.00 Hose Allowance At Source 100 155.47 ..... Route 2 ..... DR 1.1010 13.10 4.41 150 0.031108 Pf 0.614 102 103 181-0 18'-6 13.10 4.9 7.148 7.546 Sprinkler, E(T-0), T(5'-O) 17:-9 2 -0 1 9'-9 Pe Pv -0.217 cot ..... Route 3 ..... DR 1.1010 13.64 4.59 150 0.033496 3:-6 Pf 0.519 104 105 181-0 181-6 13.64 4.9 7.743 8.046 Sprinkler, E(7'-O), T(5'-O) 12 -0 115-6 Pe �Pv -0.217 @4 ..... Route 4 ..... DR 1.1010 15.77 5.31 150 0.043842 1 -6 Pf 0.504 106 107 181-0 18'-6 15.77 4.9 10.359 10.646 Sprinkler, T(5'-O), C(5'-O) 10 -0 11 -6 Pe Pv -0.217 og' 00f Va!�,6s. aFd"Fitj�gs (Q= 120 only)", Actual Inside Diameter 4,87 Factor Schedule 40 Steel Pipe Inside Diameter 1 Multiplier Value Of C 100 Multiplying Factor 0.713 130 140 1.16 1.33 150 1.51 & @ M. E. P. CAD, I nc. fflAutoSPRlNK@ 112 v12.0.61.0 Page 5 Job Number: CASCA18-2002 Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Lenath AO Arm -Over Diameter Inch ALV Alarm Valve BIL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90* FIR Feed Riser Friction Loss psi/Foot cpIg Coupling MS Miscellaneous HWC Hazen -Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90* Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45' Elbow Eel 111/4' Elbow Ee2 221/2* Elbow f Flow Device I'd Flex Drop FDC Fire Department Connection fE 90' FireLock(TM) Elbow fEE 45* FireLock(TM) Elbow fIg Flange FN Floating Node fT FireLock(TMI) Tee 9 Gauge GloV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle Pi Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90* Tr Tee Run U Union WirF Wrsbo WMV Water Meter Valve Z Cap Q M.E.P.CAD, Inc. �f jjAutoSPRINK(& 12 02.0.61.0 Page 6 BDRM#3 BATH BDRM #2 40 3 r F_ 7 LDRY L L_ _j A L _J M DINING It Al KITCHEN UNIT 101 '9 L 3' 1 0 LIVING CHECK VALVE—, 1%" SINGLE PORT FDC AT 2W' AFF U Li MAIN FLOOR SCALE: 1/4" = 1'-0" SEE RISER DETAIL BDRM#2 BATH BORM #3 LDRY * 4 '74 r 9 KITCHEN --- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — EAST ELEVATION DESIGN NOTES: 1. CASCADIA FIRE PROTECTION TO DESIGN AND INSTALL A NEW WET FIRE SPRINKLER SYSTEM BASED ON NFPA #1 3R - 2013 EDITION, CITY OF EDMONDS, AND THE FIRE SPRINKLER MANUFACTURIER'S REQUIREMENTS. DESIGN DENSITY IS.05 GPM WITH FOUR FIRE SPRINKLERS FLOWING AND A MAXIMUM SPACING OF 16'x 16' WITH A MAXIMUM DISTANCE OF 8'-0" FROM WALLS PER MANUFACTURER'S REQUIREMENTS. 2. FIRE SPRINKLERS ARE NOT REQUIRED IN BATHROOMS LESS THAN 55 SQ. FT. 3. FIRE SPRINKLERS ARE NOT REQUIRED IN CLOSETS WHERE NFPA 13R REQUIREMENTS ARE MET 4. ALL FIRE SPRINKLER PIPE AND FITTINGS SHALL BE LISTED CPVC. 5. HYDROSTATIC INSPECTION TO BE PERFORMED AFTER PIPE INSTALLATION. 6. PIPE HANGERS AND SEISMIC BRACING TO BE INSTALLED PER NFPA 13R. 7. AUXILIARY DRAINS TO BE INSTALLED AT LOW POINTS. 8. CASCADIA FIRE PROTECTION IS NOT RESPONSIBLE FOR PAINTING OR WIRING. 9. OWNER IS RESPONSIBLE FOR MAINTAINING TEMPERATURES ABOVE 40 DEGREES TO AVOID FREEZING. 10. NEW BUILDING IS CONSTRUCTED WITH COMBUSTIBLE MATERIALS. DINING UNIT 102 LIVING TO SYSTEM DRAIN RISER DETAIL (D2" SUPPLY BY OTHERS 2 x 11/2 REDUCER 11/2" BACKFLOW PREVENTER 11/2" RELIABLE RISER WITH FLOW SWITCH, MAIN DRAIN, AND PRESSURE GAUGE 1 % x 11/4 BUSHING SPARE HEAD BOX �PROPERTY LINE r r UPPER FLOOR SCALE: 1/4" = 1 1-011 RISER LOCATION 0-- �R NEWMULTI-UNIT CP6� A11110VILI Al NOTED 13Y E. GIN �111111G .Z F-1 I I!F-15-L A IC7 Date: , VLO - * A _c0A1Tz*1%E- AFS W30 FDC ELECTRIC BELL wAu 62� I"STAU" . —(:;n I ry AtIPPOV00 r-)VIL 60-11­1 El VIIIIII PLftS r0154 -fig!r� tAA0, 06VA, 72ND AVENUE W ------------------------------------ CITYWATERMAIN WATERFLO IKII=n STATIC: 72 PSI RESIDUAL: 49 PSI FLOW: 2,630 GPM ,SCIURCE: EDMONDS, SITE PLAN SCALE:NTS Edmonds Multi Unit KemoEe Area: unit zui CALCULATION DESIGN CRITERIA. ­n NFPA#13R-2013 ­­yc­ Residential � C­E­­D__26(L_ Ft' DEN- .05 GMIF­ 4 sprinklers F, '_NKLER Reliable Model RFC49 4.9 ­R PL11 IF01M STA_ PS' 69 Fl. 0 G" AT MSE OF R(SER SYSTWREm"'s 55 47 GPM@ 67 70 Psi Hmp, N, 1 PIM St,p MAX HANGER SPACING 1" CPVC: 6'-0" 1 1/4"CPVC: 6'-6" RE PROTECTION PLAN 1 1/2" CPVC: 7'-O*,:II'Y 2" CPVC: 9-0.. 1 RECEIVED LL� AUG 29 2018 CASCA18-2002 'F�-O� _au� C- f^'j I h I", t Casicadia FIRE PROTECTION PO BOX 206 PUYALLUP, WA98371 PHONE: (253) 202-3909 SE NUMBER #CASCAFP833L2 cascadial'irepro com w z C) cij z 0 0 C) 0 w w 0 w cr Mw X' w T W 11 3: T ow z 16 6 w co 8 �03 L16 11111111 CITY. OWNER: ARCHITECT GENERALCONTRACTOR OTHER: 00 REVISIONS 7� APPROVED B 'f D MN ^-r . (W Alor &-oc-4 A NORTH SCALE: 114" 1'4' N 0' 1' 2' N_ C­di, Fi, fttedi­ LLC CASCAFP833L2 �,,d x, Q f 8-27�18 a =1 ............ EDMONDS MULTI -UNIT 20904 72ND AVENUE W EDMONDS, WA 98026