Loading...
BLD20190581OV ED 4 �-�Jf 0, CITY OF EDMONDS 1215THAVENUENORTH -EDMONDS, WA 98020 41� PHONE: (425) 771-0220 - FAX: (425) 771-0221 ,)C. 1 %911 STATUS: ISSUED 05/28/2019 i — - -_ ----Pe-irmit#:-BL-D20,1-90,5--8--I-I BUILDING PERMIT Expiration Date: 05/28/2020 Project Address: 21405 82ND PL W, EDMONDS, L Parcel No: 00373600300800 1 w uslu I'm 1hyll"10 Ila I tum �� WEST EDMONDS COOPERATIVE WASHINGTON ALARM INC WASHINGTON ALARM INC PRESCHOOL C/O RON HANER C/O RON HANER CIO ST ALBANS PARISH-EDMONDS 2030 AIRPORT WAY S 2030 AIRPORT WAY S 21405 82ND PL W SEATTLE, WA 98134 SEATTLE, WA 98134 EDMONDS, WA 98026-7434 (206) 328-1800 (206) 328-1800 LICENSE gL WASHIA1282C3 EXP: 12/05/2019 JOB DESCRIPTION REPLACEF/A PANEL, E)USTINGSMOKIES IN CLASSROOM AREA. ADDING SMOKE IN BATHROOM, NOTIFICATION TO CLASSROOM AREA. VALUATION: S6,500 PERMIT TYPE: Commercial PERMIT GROUP: 79 - Fire Alarm GRADING. N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP - OCCUPANT LOAD� FENCE: 0 X 0 FT.) CODE: IOTHER ------- OTHER DESC IZONE: INUMBER OF STORIES: 0 IVESTED DATE: INUMBER OF DWELLING UNITS 0 ILOT #� FXISTING AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 PRO POSEDAREA 0 1 ST FLOOR: 0 2ND FLOOR. 0 3 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS 0 BATHROOMS: 0 1 RFIDROOMS: 0 BATHROOMS: 0 FRONTSETBACK SIDESETBACK REAR SLTBACK KEQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: PROPOSED: SETBACKNOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERM NTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. &Signat Print Name Released [g Date �w oy ATTENTION S L L TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBCI 09/ IBC] 10/ IRCI 10. = FIRE = APPLICANT = ASSESSOR = CITY STATUS: ISSUED BLD20190581 CONDITIONS • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating fromtemporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00arnto 6:00prn on weekdays and 10:00arn and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold han-nless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly frorn the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING ENGINEERING (426) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you FIRE (425) 775-7720 3. Tben: Perm its/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand corner) (425) 771-0220 RECYCLING (425) 276-4801 _6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection — being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Alarm System Acceptance • F-Fire Compliance • F-Fire Final ,JA4'- � A 0 8 S - � DEVELOPMENT SERVICES COMMERCIAL & MULTI -FAMILY BUILDING PERMIT APPLICATION IT, otis 9 F 1215" Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 11 Fax 425.771.0221 PLEASE REFER TO THE COMMERCIAL & MULTI -FAMILY BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite City State, Zip): 21405 82nd P1 W, Edmonds, WA 98026 Parcel #: 00373600300800 Subdivision/Lot #: Project Valuation: $ 6500 APPLICAN Treyven Chin Phone: 206-436-5300 Fax: 206-322-7214 Address (Street, City, State, Zip): 2030 Airport Way S Seattle, WA 98134 E-Mail Address: Permitsgwashingtonalarm.com PROPERTY OWNER: St. Alban's Episcopal Church Phone: (425)778-0371 Tax7 Address (Street, City, State, Zip): 21405 82nd PL W, Edmonds, WA 98026 E-Mail Address: LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* Washington Alarm Inc Phone: 206-328-1800 ax: 206-322-7214 Address (Street, City, State, Zip): 2030 Airport Way S Seattle, WA 98134 E-Mail Address lnstallOwashingtonalarm.com *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. Date: WASHIA1282C3 12/5/2019 City Business License #/Exp. Date: NR-014536 DETAIL THE SCOPE OF WORK: Replacing fire panel, replacing existing smokes in classroom area. Adding smoke in bathroom, Adding notification to classroom area. PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: I st Floor: -sq. ft. 2d Floor: -sq. ft. 3 rd Floor: -Sq. ft. Basement: sq. ft. Garage: -sq. ft. Deck/Cvrd Porch: -sq. ft. Other: sq. ft. Retaining Wall- Ye7s No Fire Sprinklers: Yes No L] Occupancy Group(s): Occupant Load(s): Tvp s of Construction: Grading: Cut -cu.yds. Fill cu.yds. I Cut/Fill in Critical Area: Yes D No 0 I declare under penalty ofperjury laws that the information I have provided on this formlapplication is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Teyven Chin Owner []Agent/Other 2 (specify): Permit Coordinator Signature: Date: 5/1712019 FORM E LABuilding New Folder 2010\DONE & x-ferred to LBuilding-New drive\Form E 2014.doex Updated: 1/17/2014 I Equipment Type MECHANICAL Appliance/Equipment Information (new and relocated) -I Total # Furnace Gas #—Elec #—Other:— # BTUs: <100k— >100k— Location(s) Air Handier / VAV (circle selected) Gas #—Elec #—Other:— #—CFM: <10k >10k_ Location(s) AC / Compressor Boiler / Heat Pump Roof Top Unit (circle selected) Gas #—Elec HP: #—Other:— <3,3-15,15-30 #_ BTUs: <100k, _100k-500k, —500k-lMil Location(s) Hydronic Heating Gas #—Elec #—In-Floor —Wall Radiant— Boiler BTUs: Location Exhaust Fans (single duct) Bath # Kitchen # Laundry # —Other: # Fireplace Gas #—Elec #—Other:— # Location(s) [7Dryer Duct Appliance Type FUEL GAS Appliance/Equipment Information (new and relocated) Total # AC Unit BTUs: Location(s): Furnace BTUs: Location(s): Water Heater BTUs: Location(s): Boiler BTUs: Location(s): Other: BTUs: Location(s): Fireplace/Insert BTUs: Location(s): Stove/Range/Oven Dryer Outdoor BBQ TOTAL OUTLETS PLUMBING FIXTURE COUNT Fixture Type (new and relocated) Total # Fixture Type (new and relocated) Total # Water Closet (Toilet) Pressure Reduction Valve/Pressure Regulator Sink (kitchen, laundry, lavatory, bar, eye wash, etc.) Water Service Line Tub/Shower Drinking Fountain Dishwasher Clothes Washer Hose Bib Backflow Prevention Device (e.g. RBPA, DCDA, AVB) Water Heater Tankless? YesE] No E] Hydronic Heat in: Floor E] WaIIE] Floor Drain/Floor Sink Other: Refrigerator water Supply (for water/ice dispenser) Other: FORM E LABuilding New Folder 201000NE & x-ferred to L-Building-New, drive\Form E 2014.docx Updated: 1/17/2014 0 SILENT Model 5208 KNIGHT Fire Alarm Control Panel by Honeywell with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in LIL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features * 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones * Supervised zone expanders and 1/0 modules can be mounted remotely from the main control panel * Event History Buffer (150 events) with date/time stamp * All zones are compatible with 2- or 4-wire detectors * 8 selectable/programmable output patterns for notification appliance circuits * Built-in Digital Alarm Communicator Transmitter (DACT) * 4 Notification Appliance Circuits * 4 programmable general purpose relays * Programmable smoke verification, pre -alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms * Programmable from the built-in control panel touchpad, remote annunciator, or WindowsO SKSS downloading software * Direct connect port for on -site up/downloading with Windows@ SKSS downloading software * B u i I t-in walk test featu re * Single or dual interlock water releasing capability * Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions * Programmable AC trouble relay Built-in synchronization for appliances from AMSECO(�,, GentexO, Faraday, System Sensor@, and Wheelock@ Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10. 16 cm) Ea SK-5208 • Plex-2 Door Option • SK-SCK Seismic Compliance Kit Operating Temp: 32'to120*F Listings and Approvals (0' to 49* C) - LIL Listed Humidity: 10 - 93% noncondensing * CSFM Listed . MEA approval 429-92-E Vol. XIII Optional Accessories . OSHPD 0 • SK-5235 LCD Remote Annunciator • SK-5217 10 Zone Expander a7y (2 max. per system) * SK-5280 Status Display Module (8 max. per system) * 5220 Direct Connect Module * 5824 Serial/Parallel Printer Interface Module * SKSS Downloading Software I1*21g; MA r1all MAY 2 0 2019 BUILDING Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line I _`�* Telephone Line 2 F Direct Connect For On -Site Programming 2 Class A (Style D) or Class B (Style B) Initiation Circuits 8 Class B (Style B) Initiation Circuits I �'� it-1 Programmable Form C Relays Notification Appliance Circuits 5235 Remote Annunciators Do SBUS Devices 5280, 5217, & 5824 To AC This document is not intended to be used for installation purposes. We try to MADE IN AMERICA 0SILENT keep our product information up-to-date and accurate, We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev E �� subject to change without notice. For more information, contact Silent Knight @ 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical support, Please call 800-446-6444. www.silentknight.com SYSTEM SENSOR - Photoelectric Smoke Detectors System Sensor i3- series smoke detectors represer significant odvancemen tin conventional detecti Th.oi3ftlmilllicfn"nt4p,qr)nthroo rinrinlocmincttil ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In -line terminals with SEMS screws Mounts .10 octaaonal and single -gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop'N Lock attachment to base - Removable detector cover and cham ber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual -color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings MFA MSFM LISTED APPROVW approved approved c us S911 3011446 7272-16S3:152 251J,01-E 20�3 3180-32 Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre -wire bases (included with heads). The large wire entry port and in -line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, P heads plug into the base with a simple Stop-Drop'N Lock' action. Intelligence. i3 detectors offer a number of intelligent featuies to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED - indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the R protocol.The SENS-RDR, a wireless device, displays the sensitiVityof i3 detectors in terms of percent -per -foot obscuration. Instant inspection.The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of -sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. (-C*) Smoke Detector Specifications Smokedetecto. shall be a System Sensor*15etes model number listed to Undervoiters Laboratories UL 268 for Fire Protection Signaling Systems,The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectfic/theirtial (Model 2WT-13, 4W`17-13) with thermal sensor rated at 1 35'F (5 7.2C).The detectoi shall include a mounting base for mounting to 31/2-inch and 4Anch octagonal, single -gang, and 4-inch square back boxes with a plaster ring, or directmount to the ceiling using drywall anchor5. Wiring connections shall be rnade by rneans of SEMS screws.The detector shall allow pre-wirling of the base and the head shall be a plug-in type. 11he detector shall nave a nominal sensitivity of 2.5 percent -per -foot nominai as measured in the UL smoke cox, T ne detector shall oe capable of automatically adjusting its sensitivity by means of dr'ft compensation and smoothing algoftnins.-he detecto. shall provide dual - color LED indication that blinks to indicate power up, normai standby, out of sensitivity, alarm, and freeze trouo-e (Model 2W7-B, 4WT-13) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire rnodels sha� inoude a maintenance s7gnal to indicate the need fbr rna;nteriance at t;)e alarm control panel and shall provide a ioop testing capability to verify the c',cult witnout testing each detector 'nclividuai'y Operating Voltage Nominai: 12/24Vnon-polarized Minimum: 8.5v Maximum: 35 V Maximum Ripple Voltage 30% peak to oeak of applied voltage StandbyCurrent 2-wire: 50 PArnaximurn average; 4-wire:501jA maximum average Maximum Alarm Current 2-wire: 130 mA I mited by control panei; 4-wire: 20,-nA @12 V, 23 rnA @ 24 V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wiie: n/a; 4-wire: 05 A @ 30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mrn) diarneter;2.0 ',nches (51 mm)neight Weight 6.3 oz (178 g) Operating Temperature Range 2W-13 and 4W-B: 32'F to 120'F (OC to49C); 2WT-B and 4WT-B: 32*1F to IWF VC to 37.8C) Operating Humidity Range 0 to 9596 RH non -condensing Thermal Sensor 135*F (57,2*0 fixed FreezeTrouble 2WT-B and 4WT-B only: 41'F (5'C) Sensitivity 2.50/o/ft norninal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single -gang back box 4-inch square back box with a plaster ring Directmount to ceiling LED Mode Green LED Red LED Condition Duration Power u p Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 Seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Neeze trouble Off Blink every 10 seconds Alarm Off Solid Ordering Information Model 2Vk/-B Thermal No Wiring 2-wire Alarm Current 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA rnax. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23 rnA@ 24V 4WT-B Yes 4-wire 20 mA @ 12V. 23 mA@ 24V Accessories 2W-MCD2 2-wire loop test/ maintenance module RT Removal/ replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter 02 System Sensci. EM Oangewftho� ncUce.V1Jt%­n­m fet Sys T 3825 Chic, Avenue - St. Chat les, IL 60174 Pmd� speciftxiwssubl� . cl 11 —rent 1Xod­nFwrAatcc�indudiad the 1—versini &I fts dam sheet. SENSOff Phone: 800-SENSOR2 - Fax: 630-377-6495 AOS-0318-007. 6!09. 0216Q AES-7794 hteMPro Fhem —_46�'<__tCCRP0FR=AT310N � F/onrAlatrmeM o/n/itoirNlnget Full Data Module Overview The AES-7794 IntelliPro FireTM is an add -on module for AES subscribers that enables transmission of full alarm zone data from an alarm panel to a central station over an 0 N70F established AES-IntelliNet network. AES subscribers with IntelliPro Fire can operate in applications with or ILY, .0 without a phone line providing full emulation of the phone line for the ka alarm panel communicator. Intelli P ro .7 Fire supports most popular alarm com- munication protocols including Contact ID and Pulse as well as Modem 11 and Modem III converted to CID.* Easy Installation 1111?11�OFM� - I& IntelliPro Fire easily installs in the subscriber XAP- housing and is powered from the transceiver module, requiring no additional power connections. AES subscribers can be ordered with IntelliPro Fire installed. IntelliPro Fire is easy to program using the AES Handheld Programmer. Features • Commercial fire alarm applications - with or without phone lines • Transmits full alarm data from any Contact ID or Pulse format fire alarm panel • Supports expanded event reporting from Bosch Modem 11 and Modem III alarm panels • Primary or back-up communications • Universal wireless alarm transmitter - works with most manufacturers' panels • Easy to install in AES subscriber • Easily programs using an AES Handheld Programmer • Option to monitor telephone lines *The AES-7794 IntelliPro Fire converts Modem Ile and Modem Illa2 codes to Contact ID for transmis- sion over the IntelliNet network and supports those alarm panels listed in the table located at www.aes-intellinet.r,om/AES-IntelliNet-7094 Intel liPro.html. This table will be updated as additional panels are tested. AES Corporation 1285 Newbury Street I Peabody, MA 01960 USA Call 800-AES-NETS (800-237-6387) or +1 978-535-7310 1 Fax +1 978-535-7313 1 Email info@aes-intellinet.com Web www.aes-intellinet.com Technical Specifications Transmits full data to AES receiver using Contact ID or Pulse formats Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile*, and Modem Illa2* 1/0 Connections - AES subscriber with power Handheld/PC programming port POTS incoming phone line Phone output from alarm panel Trouble output (form C relay) Size - 2.8 x 5.0 inches (7.1cm x 12.7cm) Power Requirements 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit How to Order Model Description 7794 IntelliPro Fire 7744F-P UL Fire Subscriber w/7794 (4 reversing polarity & 4 EOL inputs) 7788F-P UL Fire Subscriber w/7794 Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2-way commu- nicatians capability provides easy installa- tion, expansion, and management when compared to alternative communication methods, both wired and wireless. Copyright 2011 AES Corporation AES-InlofflNot is a registered trademark of AES Corporation 7794/11/03 it �, 15 Y5 YEPL R �A EEPS.Tolw q� Se�edaWe Output Homs, Stirobles, and Horn/ftrables SpectrAlert* Advance selectable -output horns, strobes, and horn/strobes are rich with features guoranteed to cut installation times and maximize pro�ts. The SpectrAllert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field -selectable candea settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box. The two -wire mounting plate attaches io a single -gang junction box. Next, connectthe notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plates terminals. The device will temporarily hold in place with a catch until it is secured with a captured Mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. am RK11 _A M W a", 111 A M; Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Plug-in design Field selectable candela settings on wall and ceilingunits: 15, 15/75, 30, 75, 95, 110,115,135,150,177,185 Same Mounting plate forwall- and ceiling -mount units Shorting spring on mounting plate for continuity check before installation Tamper resistant construction Outdoor wall and ceiling products rated from -40*F to 15 I'F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts - Rotary switch for horn tone and three volume selections -Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements - Outdoor products rainproof per UL 50 (NEMA 3R) - Compatible with MDL sync module Agency Listings SIGWMNG 73111-16111W(irldwst.b��) 0 37 (outdoor itmbes) ;111 -5. LISTED APPROVED zMEA pproved 7135-76531V(hvn�.chlms) S1011 30235-1 MEA-151,5-E S55. S359-1 Advance SiDecifications General SpectrAiertAdvance horns, strobes and horn/strobes shall mount to a standard 4x4 x 11/2-inch back box, 4-inch octagon back box or dOLible-gang back box. Two -wire products shall aiso mount to a single-gang2 x4 x 11/8-inch back box. A universalmounting plate shall be used for mountingceiling and wall products. The notification appliance circuit wiring shall terminar.e at the universal mounting plate. Also, SpectrAleit Advance products, when used with the Sync -Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts, 24-volt rated notiffication appliance circuit outputs shall operate between ' 7 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfilteied powei supply� Strobes and hori-Vstrobes shall have held -selectable candela settings including 15, 15/75, 30, 75,95, 110, 1 115,135,150,177,185, Strobe The strobe shall be a System Sensoi SpectrAleit Advance Model listed to UL 1971 andshall be approved for fire protective service.The strobe shall be wired as a primaty-signaling notification appliance and comply with the Americans with Disabilities Act requirements forvisible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range. The strobe Ight. shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlei t Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The hon-Vstrobe shall be wired as a primary -signaling not! rication appliance and comply with the Americans With Disabilities Act requirements lot visible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range.The strobe light shall consist ofa xenon flash tube and associated lens/reflector system. The horn shall have three audibi li ly options and an option to switch between a temporal thtee-pattern and a non-ternporal (conti nuous) pattern. 1 hese options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sou; )der. The horn on horri/st.obe models shall operate on a c ocled or non -coded power suppl y. Outdoor Products SpectrAlerr Advance outdoor horns, strobes and horn/strobes sha 11 be iisted for outdoor use by UL and shall operate between rninus 40 degrees and 15 1 clearees Fa nrenneit. The products shall be listed for use with a Systern Sensor outdoor/weather.orooi back box with half inch and three-lourms inch conduit entries - Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL I sted to UL 4CA and shall be approved toi fire protectNe service. The module shall synchionize SpectrAlert strobes at 1 Hz and horns at te. nporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe i nodels over a single pair ofwires. The module shall mount to a 411/16 x 411/16 x 21A-inch back box. The module shall also control two Style Y (class 8) circuits or one Style Z (class A) circuit The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize al I the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32'F to 120*F (OC to 49*C) K Series Operating Temperature -40*F to 151 *F (-4TC to 6610 Humidity Range 10 to 93% non-conclensing (indoor products) Strobe Flash Rate I flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (1 2V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8"diameter x 2.5- high (1173 mm diameter x 64 mm high) Wail mount dimensions (including lens) 5.61 x 4.7W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7Wx 1.3-D (142 mm L x 119 mm Wx 33 min D) Wall -mount backboxskirt dimensions (BBS-2, BBSW-2) 5.91 x 5.0*W x 22D (151 mm L x 128 mm Wx 56 mm D) Cei I ing-mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1 'diameter x 2.25'high (180 mm diameter x 57 mm high) Wa I kmount weatherproof back box dimensions (SA-WBB) 5.7-1- x 5.1"W x 2.0-D 0 45 inn) L x 130 mm W x 51 mm D) Cel I ing-mount weatherproof back box dimensions (SA-WBBQ 7.1 'diameter x 2.0'high (180 rnm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time varying power source that is used on some power supplyand panel outputs 2. P S, PC, and SC products will operateat 12V nominal only ior 15 and 15175 cd. A05-0395-00� UL Current Draw Data ILL 6iax.5trobeLurrent I raw (MA RMS) IL Max. Aorn Current Draw (rnA Ri; B-1 7.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWIR DC FWR Sound Pattern dB DC FWR DC FWR Standard !23 128 66 71 Temporai High 7 55 69 75 Candela Range - D-/75� 142 148 77 81 -emporal Medium 44 49 58 69 30* NA NA 94 96 7emporal LOW 38 44 44 48 75* NA NA 1� 58 153 Non -temporal High 57 56 69 75 95* NA NA 18! 176 Non -temporal MediLM 42 50 6C 69 110 NA NA 202 195 Non -temporal Low 41 44 50 50 115 NA NA 210 205 Coded Hign 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 5' 56 69 Candela Range 150 NA NA 246 220 Coded LOW 40 46 52 50 177 NA NA 281 251 1 o� ,j NA NA 286 258 UL Max.Current Draw (rnA RMS),2-wire Hom/Strobe, 8-17.5 Volts Standard Candela 16-33 Volts Range (15-115 cd) DC Input 15 15/75 is 15/75 30 75 95 110 115 iemporai High 137 '47 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 T lemporal Low 132 143 66 77 93 154 179 198 207 Non-ternporal High 141 152 91 100 116 176 201 22'. 229 Non-ternporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131, 144 68 79 96 156 182 201 2110 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 '160 184 194 201 Non -temporal High 142 161 103 112 126 181 203 221 229 Non -temporal Medium 134 155 85 95 110 166 189 208 216 Non -temporal Low UL Max. CurrentDraw, (rnA DC Input 132 RMS), 2-wire Horn/Strobe, 16-33 Volts 135 150 154 80 High Candela 177 90 Range 185 105 (135-185 cd) FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 lernporal Medium 235 253 288 297 lemporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 24�9 256 Non-ternporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Non -temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela i Horn and Horn/Strobe Output (dBA) ratings must be reduced in accordance with this table. 24Volt Nominal 8-17.5 16-33 Strobe Output (cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -4o*r Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 Do not use below 32'F 5175 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 I Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non -temporal High 82 82 88 88 93 92 100 100 5 Non -temporal Medium 78 78 85 85 90 90 98 98 6 Non -temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 81 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 �Settings 7, 8, and 9 are not available on 2-wire horn/strobe. A05-0395--)D3 Alert Advance Dimensions 0 Ceiling -mount horn/strobes F\ T:1" 11.1' 2.2,5'1 2.0* Dia. 2.23ZI D i a. C 2.0' 0 Q I C__ 5.7' 0 'Ob� 0/ 0 . 0 Ibb.. 61 1�61 Q�!5 ul� Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes (cont'd.) P2R*t 2 wire Hon i/Strobe, Sta ndard cd*, Red PC2W*- 2 -wire Horn/Strobe. Sta ndard cd. White P2RH* 2-wire Horn/Strobe, High cd, Red PC2VVH*t 2-wire Horn/Strobe, High cd, White PARK' 2-wire Horni Sta nclard cd, Red, Ou tdoor PC4R 4-wire Horn/Strobe, Standard cd, Red P2RHK* 2-wire Horn/Stiobe, High cd, Red, Outdoor PC4RH 4-wire Horn/Strobe, High cd, Red P2W* 2-wire Honi Standard cd, White PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P2WH* 2-wire Horn/Strobe, High cd, White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4R* 4-wire Horn/Strobe, Standard cd, Red PC4W 4-wire Horn/Strobe, Standard cd, White P4RH* 4-wire Horn/Strobe, High cd, Red PC4WH 4-wire Hom/Strobe, High cd, White P4RK 4-wire Horn/Strobe, Standard cd, Red, Ou tdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W* 4-wire Horn/Strobe, Standard cd, White SCRH* Strobe, High cd, Red P4WH* 4-wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR*t Strobe, Standard cd, Red SCW*t Strobe, Standard cd. White SRH*t St be, High cd, Red SCWH*t Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Homs SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW* Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd, White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red PC2RH* 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall,White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Ou tdoor BBSC-2 Back Box Skirt, Ceiling, Red PC2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor BBSCW 2 Back Box Skirt, CeilingWhite Notes: *Add'-P'tomodel numberforplain housing (no'FIRE"marking oil cover),e.g., P2R-P I Add'-SP'to model nurnberfor'FLIEGO"marking on covere.g., P2R-SP t'Standard cd,refers to strobes that include 15,15/75, 30, 75, 95, 110, and 115 candela settings.'High cd,refers to strobes that include 135,150, 177, and 185 candela settings. All outdoor units ending in'Kinclude a weatherproof back box. �W6 �Wm Sensor. SYSTEM 3825 Ohlo Avenue - St. Charles, IL 60174 Produa specificMion—byw to chancipmthout rodoe Visity�emse—r— for ZA SENSOR- Phone: 800-SENSOR2 - Fax: 630-377-6495 m—tpoduainforrrafon, ricludinq the attest version ofthis d- sheet. A-15-0395 1103 - 12/06 - � 16 i 6 Batteries Sealed Lead -Acid Batteries Technical Specifications N:Ynral Wt3g� 12V N:YnrEd Capaty 7.5 Ph (20 Ft Pat2) Dn-Erdcrf; Leigh 151 rrm Wdh 65 m-n Fbcjt 96 m-n Tual 1-bgl-tvV TeTirel: 103 m-n Wigli AMcK 251 Kg (5.53 lb.) Capadty Characteristics G.t-dfVdtag2 20 Ff Rate (.37 A) 7.5 Ah 1.75 v/c@ 10 �lr Rate (.69 A) 698 Ph 1.70v/c 5 1-f Fbte (1.27 P) 637 Ph 1.55 V/C I Ft Fbte (4.5 A) 4.5 Ah Bloc PEr Cdl Qw9a\kltxy(w,st&v Rcat 13.5-13.8 225-230 Cycle 144-14.7 240-245 Ds"rq? Grrert ATp (5 secDrd mmnuTj 8C) Ds"rT GrrErt Prrp (ma)dnunmrtmrLE) 50 Mw ChargR G-rrert 216 A Ap:rcv- Final G-arg2 CLUOI 0.014(14nA AqxoL HrEi G-arg2 C, irrgt 0.07 (70 n-6 TErr-rinal Type TjpE!A/ (Gcpdcnal) SElf IISCIWT 9 MTft @ 21'C Case AtErial ABS - C-ray* a Black DRmdung5intenmaharingpoazes jiedfkwmm)idw7��mum *aW qtmis Ram Peorchm ABIS interstatebatteries.com Specification Sheet SLAI 075 U-,t � (--, 0 5Q w � O� ' " 1-1 IN 1111 �F FIRE ALARM PLAN ��'ALEL �l APPR . Ep ��l REQ=-wED MAY 2 0 2019 BUILDING �P��Q N1908 .It W. Exp. 01/01/2021 Fbv �(� sy't... z z 0 'o Z E- V) c,2 < < Z** E- m� 0 CD m C) C12 cm bi Vf og m DRAWN TREYVEN CHIN JOB# 19083-1 CHECKED PHONG NGUYEN NICET 111 139398 DATE 5/16/2019 REVISION 0 SCALE 1/8' = l'-O' FA-01 W F Gobal PatlectValusc ,SfI,E,N'1' Project Name: ISt. Alban's Episcopal Church Standby Hours: KNICHT Project ID: Alarm Mins: Prepared By: lWashfington Alarm Derafing Factor: SK-5208 Calculations Date: Voltage Drop Warning Version 02,26.09 Threshold %:E::]� Panel ID: SK-5208 Model: SK-5208 Fire Ala" Control Panel Max NAG Current: 3.0 Amps Location: Main Sanctuary Volts, 24 VDC Max Panel Current: 6.0 Amps CkE# Circuit Nam Current Draw VAreAWG Ohms Per Lengtht) Actual Volts @ %Drop Qty Standby Alarm & Type 1000 Ft. Orl Ohms EDE SK-5208 SK-5208 Main Control 1 0.140 0.550 J4 SK-5217 K:2? 1.7 �Lne � 0.00 11�.O SK-5235 6pdr, �;K 0000 0.000 SK-5280 SK-5280 Display Mod iT000 0.000 SK-5220 SK-5220 Dir Con Mod OmOOO 06000 SK-7181 SK-7181 Zn Cnvtr 0.000 omo IDC_1 Initiating Device Ckt 1 cfg. 0.000 NA** ICC-2 Initiating DeAce CIA: 2 cfg. 0.000 NA** ICC-3 Initiating Device Gist 3 cfg. 0.001 NA- IDG4 Initiating Device Gist 4 cfg. 0.000 NA*1 IDC­5 Initiating Device Ckt 5 Oil. 0.000 NA** IDC-6 Initiating Device Ckt 6 cfg, 0.000 NA- fibc-7 Initiating Device Ckt 7 ofg. 0.000 NA" IDG8 Inithating Device Ckt 8 cfg. 0.000 NA** IDC-9 Initiating Device Ckt 9 cfg. 0.000 NA** iDC-10 Initiating Device Ckt 10 cfg. 0.000 NA** IDG-1 1 Inactive, Add SK-5217-:-, cfg. 0000 NA** IDC-12 Inactive, Add SK-5217 'efg. 0.000 NA** IDC-13 Inactm, Add SK-5217 fg. 0.000 NA** IDC-14 Inactive, Add SK-5217 cfg. 0.000 NA** IDC-15 Inactive, Add SK-5217 c1g. 0.000 NA** IDC-16 linactim, Add SK-5217 cfg. 0.000 NA** IDC-17 Inactive, Add SK-5217 cfg. 0.000 NA­ IDC-18 Inactne. Add SK-5217 cfg. O.ODO NA** IDC-19 inactive. Add SK-5217 Cfg. 0.001) NA- IDC-20 inactive, Add SK-5217 cfg. 0.000 NA­ IDC-21 Iractiva, Add SK-5217 Ott. 0.000 NA­ IDC-22 fis,icflv,� Add SK-5217 �fifi 0.000 NA- IDC-23 Inactive, Add SK�5217 �fifi 0.000 NA** f IDC-24 Inactive, Add SK-5217 �ftfi 0.000 NA** IDC-25 Inactive, AddSK5217 cfg. 0.000 W* IDC-26 jtda.fivd� Add SK-5217 �ftfi 0000 IDC-27 Inactive, Add SK-5217 cfg. 0.000 _NA-- NA- IDC-28 Inactive, Add SK-5217 cfg. 0000 NA* IDC-29 inactive, Add SK-5217 cfg. 0.000 NA** IDC-30 dacirve, Add SK-5217 i 'to- 0.000 NA** NAGA Notification Appl Ckt 1 0.000 1.186 #14 Solid LJ: 1 2.52 250 1.26 16.91 7 NAC-2 Notification Appil Gist 2 cf9. 0000 OL255 014 Solid �52 200 1.01 20.14 1.26% NAC-3 Notification Appi Ckt 3 G.ODD 0.000 -125.11d 1.59 _�.00 20.40 OaOD% NAGA Notification Appl Ckt 4 efg. 0.000 0.000 12S.Ild 71t 1.59 CAM 20.40 000% Aux Aux Power Out cgi 0�0[)D 0.000 #12Solidl 1-59 0.00 20 40 Total Alarm Current (Amps) Aland Time In Minutes 160 (5 Mina) Total Alarm AH Required Command Shortcuts Configure Circuits Print Page Total Standby Current (Amps) 0141 1.961 Standby Time In Hours 24 0.083 Total Standby AH Required 3373 (LIES Total Combined AH Required 3.54 Multiply By The Derating Factor 120 Minimum Battery AmpHours Required 4,25 DEDICATED' Acluls AES 'M "Ej RADIO I NO CONDUIT IN BOTTOM OF CAN FIRE ALARM RISER DIAGRAM [ Pro- otinfo-tion ""Ol: ct Name: St. Alban's Episcopal Church Project 10: 19083-1 no r pared By: Washington Alarm Date: 5/14/2019 Ckt. Number IDC-3 Ckt. Name: Initiating Device Ckt 3 Panel ID: SK-5208 Qty Device Current Draw Each Standby Alann Current Draw Total Standby Alarm 11 System Sensor 2W�B 0.000 Elm 1 0.001 I.M 2 Unused 0.000 0.001) 0000 OmOW Unused a000 0- 0.000 0.000 Unused 0.000 0.000 < Retum To Main I Edit De4ce Database I Totalsl 0.001 1 0.095 1 Clit. Number NAC­1 Ckt. Name: Notification Appi Gist 1 Panel ID SK-5208 Max NAG Current: 3.OAmps Qty DeAce Current Draw Each Standby Alarm Current Draw Total Standby Alarm 7 System Sensor SISC Strobe (30cd) 0-000 1 0.094 1 0.000 0.658 3 System Sensor PZIKZ HorruiStrobe 175od) 0.000 0,176 O.00O__ 0 528 Unused 2�,-. )D L. 0.000 0000 Unused OTOO-� 02 1 G2! 0000 0000 , Return To Main I Edit Device Database Totals[_ 0.000 _I Ckt. Number: NAC-2 Ckt. Name: Notification App! Ckt 2 Panel ID' SK-5208 Max NAG Current: 3.0Amps Qty Demos Current Draw Each Standby Alarm Current Draw Total Standby Alarm 1 System Semor P21PCZ Hom/Strobe (135cd) 1- 0.000 0.255 0000 0.255 Unused 0000 "I 0.000 0.000 0.000 Unused 0.000 4 0.000 0.000 0.000 Unused 0.000 0.000 O.ODO 1 O.ODO .0130 :if 0.000 � Return To Main I Edit Device Database I Totalsj 0.000 1 0.255 1 OPERATIONS MATRIX > Www FIRE ALARM INPUT SMOKE DETECTORS HEAT DETECTORS PULL STATIONS WATERFLOW SWITCHES VALVE TAMPER SWITCHES FIRE ALARM AC POWER FAIL FIRE ALARM LOW BATTERY OPEN CIRCUIT GROUND FAULT NAC SHORT CIRCUIT LOSS OF AC TO BUILDING FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION MOUNTING E� FIRE ALARM CONTROL PANEL WALL -TOP @ 66" 90 AES FIRE ALARM RADIO FIELD VERIFY F__1 FIRE SYSTEM ANNUNCIATOR FIELD VERIFY 0 SMOKE DETECTOR CEILING HEAT DEIECTOR CEILING MANUAL PULL STATION WALL 0 48" CEILING MOUNT STROBE FIELD VERIFY CEILING MOUNT HORN STROBE FIELD VERIFY E]cj HORN WALL 0 10'-0 HORN / STROBE WALL 80"-96" STROBE WALL 80"-96" ABBREVIATION DESCRIPTION SPEAXIER WE WATFACE' M<'.DE,, IRI�l (JW) 75 30 E EXISTING N NEW P PENDANT MOUNT Q -DEMCE ADDRESS-, LID001 OR 001 - "NOE' Loop (D r A - �'EINOTES DEFECTOR S ..D11UE II) R REPLACE S SOUNDER BASE WP WEATHER PROOF EOL END OF LINE RESI§TOR EDER END OF LINE RELAY 14 IT, 2 WIRNEoUTCT&A1141ffi1E1 co C AT WIRE SIZE OF CABLES (IF OIAffTED NLY 1 CABLE NEEDED) AWG AMERICAN WIRE GAUGE TWO TWISTED PAIR TWSP TWISTED SHIELDED PAIR FPLP FIRE POWER UNITE PLENUM FPLR FIRE POWER LIMITED RISER MAC NOTIFICATION APPLIANCE CIRCUIT SLC SIGNALING LINE CIRCUIT GENERAL NOTES: 1. SCOPE OF WORKi REPLACING EXISTING FIRELITE 4012 FIRE ALARM PANEL WITH NEW CONVENTIONAL 6208 PANEL. ADDING NOTIFICATION TO EACH CLASSROOM AND ADDING SMOKE DETECTOR IN THE BATHROOM. ADDING OUTDOOR HORN/STROBE ON NW CORNER OF CLASSROOMS. 2, UNLESS OTHERWISE SPECIFIED, #14/2 AWG WIRE WILL BE USED FOR THE NOTIFICATION CIRCUIT. #16/2 AWG WILL BE USED FOR THE SIGNALING LINE CIRCUIT (SLC). 3. THESE DRAWINGS ARE DIAGRAMMATIC, REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 4. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72, AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 5. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS, WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 6. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. 7. POWER FOR ALL FIRE ALARM PANELS AND FIRE ALARM POWER SUPPLIES MUST BE PROVIDED BY A DEDICATION AC BRANCH CIRCUIT. THE LOCATION OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT AND SHALL HAVE A RED MARKING IN ACCORDANCE WITH NFPA 72. 8. POWER -LIMITED AND NON POWER -LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25' AWAY FROM ANY NONPOWER-LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONFOWER-LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/DR SEPARATE CONDUITS, 9. WHEN UTILIZING CLASS 'A' CIRCUITS, SEPARATE OUTGOING AND RETURN CONDUCTORS OF CLASS 'A' CIRCUITS BY A MINIMUM OF 12 WHERE RUN VERTICALLY AND 48i' WHERE RUN HORIZONTALLY. 10. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH JUNCTION BOX. INSULATE AND TAPE BACK AT END. 11. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. 12, SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN-UP IS COMPLETED AND FINAL. 13. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. WALL -MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 4' AND A MAXIMUM OF 12' FROM CEILING. 14. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. PROVIDE A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES, 15. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES WITH FIRE ALARM CONTRACTOR, 16, UPON COMPLETION OF THE FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING, THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE SYSTEM, PER ALL APPLICABLE CODES. AND SHALL COORDINATE AND PERFORM A FINAL FIRE ALARM SYSTEM INSPECTION. 17. PROVIDE OFF -SITE MONITORING As REQUIRED BY THE INTERNATIONAL FIRE CODE, SECTION 907,6,5 AND THE LOCAL AUTHORITY HAVING JURISDICTION, le. INSTALLING CONTRACTOR SHALL PHYSICALLY, LABEL ALL INITIATING DEVICES AND NOTIFiCATION APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS 'B'). THESE LABELS SHALL BE IN PLACE PRIOR TO START-UP AND TESTING. RECIE-27JUD MAY 2 0 2019 BUILDING Ph-e .­ E.,t N. 139398 E� 01/01/2021 FV. At- Sy.U­ fl- As- z L) W UJI a z 0 'CIO E- CO C12 Cc (A (M CQ rn >. Iii z E-- 0 CD ra, CM 09 00) "1 "1 DRAWN TREYVEN CHIN JOB# 19083-1 CHECKED PHONG NGUYEN NICET III 13939B DATE 5/16/2019 REVISION 0 SCALE 1/8' = 1`0' SCHEMATIC NOT TO SCALE I