Loading...
BLD20181483-4 111111111 08 OV ED CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 4z—, PHONE: (425) 771-0220 - FAX: (425) 771-0221 17c. 1 SqQj STATUS: ISSUED 01/23/2019 Penwt#: BLD20181483 BUILDING PERMIT Expiration Date: 07/23/2019 —Project Address: 188 SUNSET AVE S, EDMONDS' Parcel No: 27032300104500 P L&V P V%TY 0 NNI N1 EP. APPLICANT CONTRACTOR BRIGIDS BOTTLE SHOP WESTERN MECH CONTRACTORS INC SCOTT DELAP CONSTRUCTION C/O CROSSING LLC SALISH 7018 S220TH ST C/O SCOTT DELAP 22833 BOTHELL EVERETT HWY STE 207 KENT, WA 98032 3517 95TH PL SE BOTHELL, WA 98201 EVERETT, WA 98208 (253) 946-9544 (206) 819-6757 LICENSE 4. SCOTTDC970BI EXP:02/06/2019 PLUMBfNG FOR TJ VALUATION: $0 PERMIT TYPE: Commercial PERMIT GROUP: 47 - Plumbing GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VB RETAINING WALL ROCKERY: OCCUPANT GROUP: A-2/M OCCUPANT LOAD: 225 FENCE: 0 X 0 FT.) CODE: 2015 IEBC/IBCfI MC/UP C/W SEC IOTHER: ------- OTHER DESC: ZONE: INUMBER OF STORIES: 0 VESTED DATE: INUMBER OF DWELLING UNITS 0 ILOT 4- EMSTING AREA BASEMENT 0 1 ST FLOOR: 0 2ND FLOOR: 0 PRO 110 S ED A R ]EA 7ASEMENT: 0 1 ST FLOOR 0 2ND FLOOR: 0 3RD FLOOR 0 GARAGE 0 DECK: 0 OTHER: 0 --- F3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER 0 BEDROOMS: 0 BATHROOMS: 0 1 BEDROOMS: 0 BATHROOMS: 0 FRONTSETBACK SIDESETBACK REAR SETB7CK REQUIRED: PROPOSED: EQUIRED: PROPOSED: IREQUIRED: PROPOSED: HEIGHT ALLOWED�O PROPOSED 0 ]REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THEWORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL_SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. tal 0 dolow C* MORENO ATTENTION ITIS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL ORA CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC1 10/IRCI 10. 09 vy E—IFIRE APPLICANT ASSESSOR CITY STATUS: ISSUED BLD20181483 CONDITIONS 0 • Installation, use and maintenance of equipment and components shall be per manufacturer's specifications, installation instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector. • In addition to the required pressure/relief valve, an approved listed expansion tank shall be installed on all hot watertanks. Per UPC 608. • Obtain Electrical Permit fi-om State Department of Labor & Industries. 425-290-1309 • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances orpolicies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00prn on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating fi-om construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly fromthe issuance for this pen -nit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. • Cross -Connection control assemblies, for back -flow prevention, are required on the following fixtures: * d is hwas hers/glas swas hers *ice maker Verify nieter/backflow assembly type and specifications. Independent certified backflowtester to perform test on backflow assembly and submit report to city. Nothing in this pen -nit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpertnitted building, structure or site condition which is outside the scope ofthe permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. THIS PERMIT AUTHORIZ_ES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING ENGINEERING (425) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: SeNces are now scheduled online. If you FIRE (425) 775-7720 3. Then: Perm its/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (425) 771-0235 5: If you don't have one already, create a assistance during office hours. login (upper right hand corner) (425) 771-0220 RECYCLING (425) 275-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • B-Plumb Ground Work • B-Plumb Rough In • B-Cross Connection Final • B-Building Final BUILDING PERMIT Office Use Only APPLICATION Permit #i Development Services I *BLD2016 Building Division 121 5th Ave N / Edmonds, WA 98020 ' 17 C. I ?, 1) ' 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: http://www.edmondswa.gov/ JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: 14- Sunse4 Avt Parcel Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: 'k, Name: Mailing Address: City/State/Zip: Phone #: Email: OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? 0 Yes 0 No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.09D. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: Wecstvui Mee-harli-C&L Co,4 -1010 3 -'1 Mailing Address: 6 S0 -LQ 0' 'St - City/State/Zip: VCX-)-t—, W k 9(�n-a Phone #: 2-S'31q`46 - qS`44 k E-mail: t�_f ry) Js C WSi-e_rn ne d--) � CA!:-, GENERAL CONTRACTOR: (if different from applicant) General Contractor: Mailing Address: 351 _1 %�6 PL City/State/Zip: C_Q(L'rC* \ok Cr?20 Phone#: E-mail: WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: CITY OF EDMONDS BUSINESS LICENSE #: TYPE OF PERMIT (Provide 0 Accessory Structure/ Detached Garage Details on Page 2) 11 Addition 0 Demolition El Mechanical 0 New Single Family / Duplex XPlumbing 13 Fire Sprinkler El Remodel El New Commercial/ Mixed Use El Re -Roof EI Signs 0 Tank 0 Tenant Improvement El Other Remodel Permit fees are based on: 1 The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICAT Basement sq ft: Finished El Unfinished El 1st Floor, sq ft: 2nd Floor, sq ft: Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other scl ft: PROJECT DESCRIPTION I certify that the information I have provided on this form/application is true, �qrrect and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Signature: Date GENERAL COMMERCIAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes 11 No El WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec other Qty A/C Unit /Compressor Air Handier /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) QtY Qty Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks %OP I Other: it> tj�Y,6 f L4 Toilets Other: GAS/FIJEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUM COUNTS (New, Relocated or re -piped) Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y/N PSCAA Case #: Critical Areas Determination: Study Required El Conditional Waiver 0 Waiver im I Fill in Place 0 Fill Material: Removal 0 FSie of Tank (Gallons) Critical Areas Determination: Study Required 1:1 Conditional Waiver 1-1 Waiver D GRADE/FILL/EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes 11 NO'E] GENERAL PROVISIONS APPLICATIONS: Appiications'are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. n V'i A —EeLr aAu, ISOLATION !'_'QU7RE1"`7NT1S . f I C-1 - -IBCDA '19CVA (3tPDAI _-BA L Nothing in this permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming, or unpenmitted building, structure, or lite condition which is outside the scope of the permit application, regardless of whether such building, :tructure, or condition is shown on the ite plan or drawing. Such building, structure, or condition may be the Subject of a separate enforcement action. I PLUMBING GENERAL NOTES I 1� VERIFY LOCATIONS OF ITEMS WITH ARCHITECTURAL PLANS PRIOR TO BEGINNING WORK. NOTIFY ARCHITECT/OWNER OF DISCREPANCIES. 2-:- ALL PIPING SHOWN IS SCHEMATIC, CONTRACTOR SHALL PROVIDE ALL OFFSETS/ELBOWS AS REQ'D TO ALLOW ROUTING AROUND STRUCTURE, ELECTRICAL, & OTHER INTERFERENCES. 3- UNSIZED PLUMBING PIPING SHALL MATCH THE SIZE OF THE LARGEST ADJACENT CONNECTING PIPE SIZE SHOWN, WHERE THE ADJACENT PIPE IS NOT SHOWN (OR NOT CLEAR), THE PIPE SIZE SHALL BE BASED ON THE GPM FLOWING IN THE PIPE (USE FIXTURE UNITS AND CORRESPONDING GPM PER THE UPC FOR DOMESTIC WATER SYSTEMS, USE WASTE FIXTURE UNITS & UPC TABLES FOR WASTE/VENT SYSTEM), AND A VELOCITY NO GREATER THAN 4 FEET PER SECOND. USE UPC CURVES FOR GPM/VELOCITY FOR APPROPRIATE PIPING MATERIAL INVOLVED. 4,. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2015 EDITION OF THE UNIFORM PLUMBING CODE, AND 2015 INTERNATIONAL MECHANICAL CODE. 5/ ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 6/ SLOPE ALL WASTE PIPING AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING WASTE PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 7' HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH SECTION 313 OF THE 2015 UNIFORM PLUMBING CODE. 8,.' PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 9� FOR EXACT ROUGH -IN LOCATIONS AND ELEVATIONS OF PLUMBING FIXTURES REFER TO ARCHITECTURAL DRAWINGS. 10. PROVIDE STOPS OR ANGLE VALVES AT ALL FIXTURES. 11' PROVIDE DIELECTR�IC CONNECTIONS BETWEEN DISSIMILAR METALS. 12. CLEANOUTS SHALL BE INSTALLED SO THEY ARE EASILY ACCESSIBLE. 13. PLUMBING EQUIPMENT, VALVES AND TRAP PRIMERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. 14!. THE PLUMBER SHALL PROVIDE AND LOCATE ALL REQUIRED FLOOR, WALL, AND FOOTING SLEEVES. I ENERGY CODE REQUIREMENTS I A' WATER HEATERS SHALL MEET THE MINIMUM EFFICIENCIES (EER) LISTED IN THE WASHINGTON STATE ENERGY CODE TABLE C404.2. B- INSULATE DOMESTIC HOT WATER PIPING WITH U=0.27 INSULATION. UNDER 1-1/2" DIAMETER: I" INSULATION. 1-1/2" AND OVER: 1-1/2" INSULATION. C�' PROVIDE ENERGY EFFICIENT MOTORS ON THE PUMP EQUIPMENT AS REQUIRED IN WASHINGTON STATE ENERGY CODE PARAGRAPH C403.2.14. MOTORS LESS THAN 1HP SHALL HAVE A MINIMUM EFFICIENCY OF 70%. D-�' TEST AND BALANCE DOMESTIC HOT WATER SYSTEM. ADJUST BALANCING VALVES FOR FLOW INDICATED ON DRAWINGS. E� COMMISSIONING IS NOT REQUIRED PER WSEC PARAGRAPH C408.4. WATER HEATING SYSTEM IS LESS THAN 200,000 BTU/HR. F' PROVIDE RECORD DRAWING, OWNERS MANUALS, BALANCING REPORT AND COMMISSIONING REPORT TO OWNER AT COMPLETION OF PROJECT. SEE C103.6 OF THE W.S.E.C. G. PROVIDE SYSTEMS OPERATIONS TRAINING TO THE BUILDING OWNER PER WSEC PARAGRAPH C103.6.4. Obtain 36I11@r?e"erTmitff:or All changes in plans and field State Labor 8,, noustries modifications shall be approved by the local jurisdiction. The design Professional shall prepare drawings as required for approval. Ckyof FAmombedding Department I, IBC 107.4 APPROVED PLIJUAN J PLUMBING LEGEND SYMBOL DESCRIPTION ABBREV. DESCRIPTION — WASTE OR SOIL (W) AFF APPROX ABOVE FINISHED FLOOR APPROXIMATELY ---------- VENT (V) ARCH AUTO BLDG BTU BTUH ARCHITECTURAL AUTOMATIC BUILDING BRITISH THERMAL UNIT BRITISH THERMAL UNIT/HOUR COLD WATER (CW) HOT WATER (HW) HOT WATER CIRCULATING (HWC) CAP CLG CAPACITY CEILING F — FIRE LINE CO COMP CLEANOUT COMPRESSOR C — CONDENSATE LINE CONN CONT COP CONNECTION CONTINUE, CONTINUATION COEFFICIENT OF PERFORMANCE D — DRAIN LINE G — GAS LINE CW DB DOMESTIC COLD WATER DRY BULB ISOLATION GATE TYPE VALVE (EXCEPT WHERE INDICATED) DEG F* DIA, 0 DEGREE FAHRENHEIT DIAMETER GLOBE VALVE DN DWG (E) DOWN DRAWING EXISTING ----DC*-- BALL VALVE G� TEMPERING VALVE EA EFF EACH EFFICIENCY ANGLE VALVE ELEC EXIST FCO ELECTRICAL, ELECTRIC EXISTING FLOOR CLEAN OUT COMBINATION SHUT-OFF & BALANCING VALVE CHECK VALVE FL FLA FLOOR FULL LOAD AMPS BUTTERFLY VALVE FLEX FPM FLEXIBLE FEET PER MINUTE (DI PRESSURE REDUCING VALVE CAL GALV. GALLON GALVANIZED SOLENOID VALVE HP HORSEPOWER GAS SEISMIC SHUT—OFF VALVE HPCW HPHW HIGH PRESSURE COLD WATER HIGH PRESSURE HOT WATER Aa— IGAS REGULATOR HW I.E. IN INTEGR. DOMESTIC HOT WATER INVERT ELEVATION INCH INTEGRAL UNION RELIEF VALVE OR SAFETY VALVE KW LWT MAX MBH MECH KILOWATT LEAVING WATER TEMPERATURE MAXIMUM THOUSAND BTUH MECHANICAL STRAINER CONSTANT FLOW VALVE CONCENTRIC REDUCER MFR MIN MANUFACTURER MINIMUM ECCENTRIC REDUCER MV NO NO. NTS PD P.D . 1. P.O.C. REF REQ'D RLA MIXING VALVE NORMALLY OPEN NUMBER NOT TO SCALE PRESSURE DROP PLUMBING AND DRAINAGE INST. POINT OF CONNECTION REFERENCE REQUIRED RATED LOAD AMPS HOSE BIBB 0 PIPE DUCT TURN UP G PIPE DUCT TURN DOWN PIPE DUCT POINT OF CONNECTION P.D.I.'A' WATER HAMMER ARRESTOR (P.D.I. SIZE AS SHOWN) PRESSURE GAUGE RM ROOM RPM SCO REVOLUTIONS PER MINUTE SURFACE CLEAN OUT A THERMOMETER &�_ TEMP TEMPERATURE THERMAL WELL TYP UNO TYPICAL UNLESS OTHERWISE NOTED V VOLTS, VOLTAGE A PRESSURE TEMPERATURE TEST PORT "PETE'S PLUG" VTR W VENT THROUGH ROOF WATT DETAIL IDENTIFICATION NUMBER W/ WITH -SHEET ON WHICH DETAIL IS SHOWN WCO WALL CLEAN OUT (��_SECTION IDENTIFICATION LETTER L K�q�;�I_SHEET ON WHICH SECTION IS SHOWN PO.1/ — LEGEND & NOTES PO.2-� — SCHEDULES P1.0 — PLUMBING PLANS P2.0 — PLUMBING DETAILS A I-) - (IA"' PLW SHEETINDEX CITY OF EDMONDS BUILB.— — —1 ... v— I— WORK IIAID� —7— DD E�7s A 1, 7�_ OWNER QP_ APPROVE[ DATE: BLDG. ON !CIAL: Elz ROB III 1\1 19 All R ConSUIting L mi"Wel 59 F n cun P, -, L Ph: 253-274-5701 Fax: 253-274-5688 Projit 1901 �'M 'ONAL P-_-8-17-19 = X a. 1",_ 0 x U) W :) 0 (1) W > C6 0 z M UJ U) Zo 0 M UJ 00 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE KEY PLAN \AV I DATE: 4 JANUARY 2018 LEGEND & NOTES H�'oljs Ll 2�'_ JAN U 9 2019 BUILDING DEMiRTIVII P 0 . 1 CITY 01: EDIJONDI �J OLatain 1.1ilarl"armlitkorm State Lal. sor & Inalusties, PUMP SCHEDULE SYMBOL SPECIFIED MFR. AND MODEL NO. TYPE SERVICE GPM HEAD FT H20 ELECTRICAL REMARKS MIN. HP VOLTS/PH SP -1 PRO FLO PF93015 LIFT PUMP SEWER 80 25 1/2 120/1 W/30 GALLON SUMP CP_1 BELL AND GOSSETT ECO CIRC XL 20-35 IN LINE CIRCULATOR DOMESTIC HOT WATER 10 10 1/12 120/1 OP ERATE FOR CONSTANT TEMPERATURE (110 DEG F) W/ BUILT IN TEMPERATURE SENSOR WATER HEATER SCHEDULE SYMBOL SPECIFIED MFR. TYPE AREA I NPUT STORAGE DOMESTIC HW ELECTRICAL AND MODEL NO. SERVED RATING I (GAL) WT I LWT FLA 1_VOLTS/_P_H_] WHI-1 BRADFORD WHITE LE 250 S3-3 TANK RESTROOMS 450OW/450OW 50 27 5 Ti I o 20 22 I CU� G to. to 1 46 1&& 1GO� _-t- PLUMBING JVEAQH� Waste / Water Sizing Project: Brigids's Bottleshop LDate] 1/7/19 Area: lWhole But ing I BTJ Daniel Steele I Fixture City DFU WSFU Each Total Each I Total CW HW Water Closet 4 ll fA 1Z It"i 04-0- 0 Lavoratory 5 1 5 trvr 3 Comp Sink 1 3,9- 3 Z P,16A- ':,trw 75wa-- Service Sink 1 3 3 3, 25 2.25 Dishwasher (Comm) 1 1 4 4 4 0 4 Floor Receptor 5,2, 0 0 0 0 0 0 0 Floor Drain 2 0 0 0 0 0 0 Hose Bib (First) 0 0 2.5 0 0 0 Hose Bib (Add'tl) 0 0 0 1 0 0 _0 TOTALS Waste pipe size per UPC: -fo—tal qZ_,j3' DFU Inch l SLOPE 2% Water pipe size per UPC: Total gpili 1 -1/2 inch CW gpm= I inch HW gpm-- =!�Sm PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION W V CW HW REMARKS -1A , WATER CLOSET 4" 2" 1. WALL M6UNT _71— HANDICAP ACCESSIBLE P-11B� WATER CLOSET 4" 2" V, WALL MOUNT P-3A LAVATORY y2" 1 Y2" y2,, y,, 2 COUNTERTOP HANDICAP I ACCESSIBLE P 3B LAVATORY XF 1 Y2 " Y2 Y2 " WALL MOUNT P 5A KITCHEN SINK 2" 1 Y2" )/2" Y2 " 3COMPARTMENT P-6A SERVICE SINK .3 2' )/2" Y2 " P-11A FLOOR DRAIN 2" 1 Y2 W/ TRAP PRIMER tl P-11B FLOOR RECEPTOR 2- W/ TRAP PRIMER I P-12A ICE MAKER - y2- W/ BACKFLOW CONNECTION PREVENTOR is _"65- t-jArTli 7, e�Advr' 7" P6t- L4 Ot 'A 1. 0 r (,io.,3 1,41 04TIll &6e- TV -,.FAR- wA-SASL' A0W. Not water delivered from public -use lavatories, and all bathtub fillers and showers shall be limited to a maximum temperature of 120 degrees F. (bidets 110 F - The water heater shall not be considered a control ------ for meeting this provision. ------ UPC 407-3 408.3 409.4 410.3 Except where specifically required to be connected indirectly to the drainage system, or when first approved by the Vent all plumbing fixtures through authority having jurisdiction, all the roof per UPC 906.0 or with a plumbing fixtures, drains, lo.pi vent per UPC 909.0. Air appurtenances, and appliances shall be adm ittance valves are not permitted directly connected to the drainage unless first approved by the system ofthe building or premisc% Building Official under an alternate inctil per UPC 301.3. UPC 704.3 Consulting LL Enaineers � Ph: 253-274-5701 Fan: 253-274-5688 Proj# 1901 IONAL (L l000 0 =) = 0 Cl) W UJ LLJ .J > 0 F_ Z LLJ 0 Za 2 Lu 00 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE _ , J KEY PLAN DATE: 4 JANUARY 2018 SCHEDULES M, ra S 0 JAN 9 � 2119 PolG QEPAF FIMEW MF EDNIK Nos STORAGE HALL (COMMON) Obtain Noilor I'lermitf om (COMMON viuse'ies ARE�) Stato La!oar & In STORAGE ApDl�NNA:ml::mT7T el —A (COMMON) Roup m "Up m r16 -A upANm OC UPAN 1 /2 CW WH-1 CP—j BELOW L741E __—(E) 2" CW STORAGE OFFICE SERVICE WALK-IN COOLER 2 11-A HALL Pll-A� 3/4" CW EAK 3/4':'w C 3/4' HW RETAIL RESTROGM RESTROOM EE30 1/2" HWC 115 114 E6k'- (00117ING) (EMSTING) 1/2" Cw 1/2- HW BAR 3/4- HW EL]l d73 T07 0 q__�] EE13 7 2-A� 0 0 <.> SEATING L=j L=j L=j L 5,K 117 613AR SEATING OUTDOOR PATIO EF� EFTO 4= 'I E03 Eg EL13 E[-� ff-hi EF� 114 STORAGE 0 0 0 —11NMT (GROUP A2 OCCUPANCY) DOMESTIC W"ATER+. SCALE: 1 /811 = i I - oll HALL FOOMMON) L!�j (06-m—MON W CONNECT TO (E) WASTE AREA) /-4" co� S--E I \ — [ Pl-A� -2- PUMPED WASTE (GROUP , ccLIPANM f JANITOR STORAGE STORAGE OFRCE 110 C jjGET 3 4" W�q 3", COOLER 2 1-9 HALL Lm—A— 3 EAK TIE R I L wl 14 RETAIL J L�j L FE_. -4- 114 w (EASTING) (E)asnmG) 5e. L4 0 BAR 5 T07 0 0 SEATING 117 Co R OUTDOOR 1 ON PATIO 06 Roo lll-� ff73 EF-�] EF-13 En EF-13 4� C� EED EE� NG 'C�04:� & 11 _F05— —10-4 STORAGE FT--F7(-) (-)FFT-F7(-) 103 MACENT TENANT (GROUP A2 OCCUPANCr WASTE AND VENT PLAN 0, SCALE: 1/8" = 1' - 0" COVERED SIDEWALK COVERED SIDEWALK CI 0 DMWING NOTES: lr ALL PLUMBING INSTALLATION SHALL BE PER 2015 UNIFORM PLUMBING CODE. W/ WASHINGTON STATE AMENDMENTS. 2.1-PROVIDE WALL CLEANOUTS WHERE SHOWN AND AS REQUIRED TO MEET CODE. 3�-FOR PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SEE PLUMBING FIXTURE SCHEDULE. 4�'-OFFSET WASTE PIPING AS REQUIRED TO AVOID FOOTINGS, FOUNDATIONS, ELECTRICAL SERVICE, AND OTHER OBSTRUCTIONS. SEE STRUCTURAL AND ELECTRICAL DRAWINGS. -5-. ALL ISOLATION VALVES SHALL BE ACCESSIBLE. LOCATE VALVE HANDLES TO TURN FULLY WITHOUT OBSTRUCTION. V SEE WATER HEATER DETAIL 1/P2.0 FOR CONNECTION OF WATER HEATERS. REFER TO KITCHEN DRAWINGS FOR PIPING CONNECTION SIZES AND QUAN11TIES AT KITCHEN EQUIPMENT. 8.-ALL FIXTURES INDICATED ON THE KITCHEN PLANS ARE TO BE CONNECTED BY MECHANICAL CONTRACTOR. %-INSTALL CONDENSATE DRAIN PIPING FOR KITCHEN EQUIPMENT. SEE KITCHEN DRAWINGS. KEYED NOTES: 2" VENT UP TO 2" VTR SUMP AND LIFT PUMP PROVIDE TRAP PRIMER PER DETAIL 2/P2.d- CONNECT TO ALL FLOOR DRAINS HAND SINK, DRAIN TO FLOOR SINK Oil- AV<--;ZD GLASS WASHER, DRAIN TO FLOOR SINK 3-COMPARTMENT SINK, DRAIN TO FLOOR SINK Or SEE DETAIL 3/P2.0 FOR ICE MACHINE CONNECTION �JVEACH i 12202 Pacific Ave. S Suite B Taoo 98 Ph: 253-274-5701 Fax: 253-274 Mal� I m"T 0. 1"",- 0 =) 7C 0 < 00,3 ::g ICE)) 0 roe moo ALL WORK SUBJECT TO FIELD [INSPECTION FOR CODE COMPLIANCE I KEY PLAN ED I IDATE: 4 JANUARY 2018 1/2" CW_// RPBP VTO ICE MAKER AIR G FITTING ICE MAKER CONNECTION DETAIL NOT TO SCALE PIPE FULL SIZE TO JANITORS S NK SEISMIC STRAPS PER UPC. CONNECT TO STRUCTURE. DRAIN PAN PER UPC 1 Stlilo La!mar & Inglusiries _ CW H W BALL CHECK VALVE EXPANSION TANK AMTROL ST-12 OR EQUAL V112- HWC WATER HEATER CP_l _____�R-10 RIGID INSULATION WATER HEATER DETAIL rfl� NTS � �-O /—CW LINE TO FREQUENTLY USED FIXTURE -Z (OR LINE AS INDICATED ON PLAN) ---TO FIXTURE (OR AS SHOWN) ISOLATION VALVE TRAP PRIMER VALVE ACCESS COVER PRIMER MANIFOLD(S) A:!::�(WHERE SERVING MORE THAN ONE FLOOR DRAIN) 1/2" (TYP.) ",,---FINISHED FLOOR TO FLOOR DRAIN TRAP (TYP.) TRAP PRIMER DETAIL Cz) NTS � �_O IVEACH 122U2 FacMc Ave. 3 Suite B Tamma, WA 98444 Ph: 253-274-5701 Fax: 253-274-5688 Proj# 1901 ST IONAL EXPIRE; B-17-19 1"'i- m o< W LLJ R.0 > C6 1"",_ z m LL, 0 cl) (1) Z M m a LLJ cl) C14, co ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE KEY PLAN IDATE: 4 JANU PLUMBING DETAILS JAN 0 9 20 P20 PROVIDE PANIC HARDNOVIE PER DID lolo.1.1 C E�E r HALL 117 lmm. Me @z" I 0 EQUIPMENT SCHEDULE Brigid's Bottle Shop lmo Osam"m CITY MICRON.$ ago min" MIAMI Nola I HAND SINK 1 KROWNE REUSE EXIST 2. 3-COMPSINKWI 1 18-83C 72X1 8.5 KROWNE REUSE EXIST DRAINEROARDS -4. 1 AD-21W 18.5)(20.5X28.S FAGOR REUSE EXIST 4 GLASSWASHER 1 UHT-SPACESAVER 24)(28X34 AUTO-OHLOR 5 BACKBAR REFRIGERATOR 1 SOC79S 7SX23X36.75 CONTINENTAL REUSE EXIST a BEER TAPS 21 MICROMATIC" 7 REFRIGERATED 3 GDM­72-LD 78X3OX78.5 TRUE REUSE EXIST MERCHANDISER 8 REFRIGERATED GDM-43,LD IIX31I TRUE REUSE EXIST MERCHANDISER 9 REFRIGERATED GDM-23-LD 27X3DX786 TRUE REUSE EAST MERCHANDISER X&eeTRSiVATER, 1 REUSEEXIST WALK-IN DISPLAY a TBD DOOR/SHELVES 12 CROWLER CANNING I MK192v2 SXIOX21 OKTOBERrA MACHINE SPAMERS 13 DRINIONG WATER I MICROMATIC REUSE EXIST TAP 14 ICE MACHINE L I CU041 5 15)Q4)07.5 SCOTSMAN 15 ICE BAGGER I 4S4ICEBAGGER 13)(10.25X36.6 REGENCY Is MOPSINK I TED l7r WATER HEATER I TBO 1 9 112 1 1 13' IM LATH BATH IBC 10171-0 UU 114 z 46 (E) Q11S1T5I N G) (EXISTING) HALL TiT EX < El M IBC 1010.1.10 OUTDOOR EXISTING GUARDRAIL @ 4? PATIO E100 ,,,7GMM FIRE FEATM 10 DOOR SCHEDULE Brigid's Bottle Shop EXTERIOR & INTERIOR DOORS PLAN! MD wpa HEIGHT(ft! NOW$ 102A 4 FOLDING PARTITION 1 101-0. T.O. 103A 2 SWING PAIR 1 51-0" 11. IOSA 1 SWING 1 T-O' 7'-0' 109A 3 SWINGWALK-IN 1 310" I.-D. 110A 3 SWINGWALK-IN 1 T-O" 11. 111A I SWING 1 T-O' ro. 112A 2 SWING PAIR 1 51-0. ro. 113A I SWING 1 3r-O" r-O. 100A 2 SWINGFAIR Tow DOORNOTIES: 1 2 3 4 L E 0 E N 0 N 0 T E 8 WINDOW ID FIN. FLR. ELEVATION DATUM 1. ALL DIMENSIONS AT EXTERIOR WALLS TO DOOR ID FACE OF FRAMING AT EXT. FACE OF WALL FP P:1 I FINISH ID GRIDLINE AND TO FACE OF FINISH (5/8" GWB ASSUMED) AT INT. FACE OF WALL, U.N.O. �E� FIXTURE /APPLIANCE ID 2. ALL DIMENSIONS AT INTERIOR WALLS TO WALL TO REMAIN FACE OF FINISH (5/8" GWB ASSUMED AT (a) SMOKE DETECTOR NEW WALL EA. SIDE OF WALL), U.N.O. 3. ALL DIMENSIONS AT CABINETRY TO EDGE SMOKE/CARBON WALK-IN COOLER WALL OF COUNTERTOPS, U.N.O. MONOXIDE DETECTOR TO BE REMOVED FAN - 100 CFM U.N.O. 1 -HOUR RATED ASSEMBLY ADJACENTTEIANT (GROUP M OCCUPMCY) 610. iv-9. 116314- 2T41/2' 20 1 0 WALK-IN jANITOR STORAGE k OFFICE CO—OL—ER 1 (REUSE DUSTING) CLOSET _T1 _2 z , ill 113 110 WALK4N COOLER 2 109 z TRASH/RECYGLE BREAK ROOM 10 108 F RErAlL ZZ12PER 101 PANIC WAnRTV BAR 11103/4' 2v-v 11 r�11119 0 0 Lj 66 7 i!n . _j I _7w IN SEATING 1 117 BAR SEATING WRAP COLUMN TO FOLDING MEING VISIT — PARrIva'a 2T-r 106 AS12M PLU I [EF rf--]�D 4FXQ8' -I �m— !gx�� �I �I UPE, 102 ROOM LED 'Pw G �ma — — — — — — — STORAGE 103 21 E Va- W-6- ADJACENT TENANT (GROUP A2 OCCUPANCY) ALL WORK SUBJECT % 6 TO FIELD INSPECTION FOR CODE COMPLIA NICE FLOOR PLAA�INIG ,,, LUU" SCALE: �3116'L'= V-10" RECE 11r)v 15 L B E L L I C R A F T A R C H IT E C T 5 4444 WOODLAND PARK AVE N SUITE 100 SEATTLE, WA 98103 MW.BELLCRAFTARCHITECTS.COM fa. 0 C_ CA 4NNJ 0 Ca xF . C`4 0 120 IN a, b': bn Ln 0 S2 " E E CM Go 10 -4 ULA a IN . A 17 � FILE NAME: BRIG-A1.0 Construction Plans.dwg SHEET SIZE: D (24 X 36) REVISIONS: NO: DATE: DRAWN BY: BGP CHECKED BY: BGP FLOOR PLAN SCALE: VARIES E D E, It' RVICES (_>