Loading...
BLD20181089I I 1 ­4 OV ED4f 1�6 CITY OF EDMONDS 1215TH AVENUENORTH -EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 12/07/2018 Pennit#: BLD20181089 BUILDING PERMIT Expiration Date: 12/07/2019 Project Address: 201 MAIN ST, EDMONDS Parcel No: 00434400700800 PEOPLE'S BANK DYKEMAN, INC GAFFNEY CONSTRUCTION C/O 2020 LLC EDMONDS CIO KELL] SMITH CIO JOE GAFFNEY 307 BELL ST 1716 WEST MARINE VIEW DRIVE 8105 BROADWAY EDMONDS, WA 98020 EVERETT, WA 98201 EVERETT, WA 98203 (425) 640-8000 (425) 259-3161 (425) 355-5500 LICENSE #: GAFFNCI I 04K3 EXP: TENANT IMPROVEMENT -MECHANICAL AND­PL(JM8INGJJNDER SEPARATE PERMIT(S) VALUATION: $741,720 PERMIT TYPE: Commercial PERMIT GROUP: 71 - Tenant Improvement GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VA RETAININGWALL ROCKERY: OCCUPANT GROUP: B OCCUPANT LOAD: 79 FENCE: 0 X 0 FT.) CODE: 2015 IBC/IMC/IFGC/UPC/W`SEC JOTHER: ------- OTHER DESC: IZONE: INUMBER OF STORIES: I VESTED DATE: INUMBER OF DWELLING UNITS: 0 LOT #: EXI S I I N'G ? % R EA BASEMENT: 0 1 ST FLOOR: 5298 2ND FLOOR: 0 PRO POSI-J) AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 .BEDROOMS: 0 BATHROOMS: 0 1BEDROOM& 0 BAT14ROOMS: 0 FRONTSEMACK SIDESEMACK REAR SETBACK REQUIRED: PROPOSED: — ��TEQUIRED: PROPOSED: IREQUIRED: PROPOSED: HEIGHT ALLOWED.0 PROPOSED:O IREQUIRED: PROPOSED: SETBACK NOTES K0 IAGREETO COMPLY WITH CITY AND STATELAWS REGULATING CONSTRUCTION AND IN DOING THEWORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL�OR HIS/HER DF=PUTY AND ALL FEES ARE PAID. 6"qcr'�y )1/-7 Iri By ATTENTION ITIS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION' HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC1 09/ 1BC1 10/ IRCI 10. = FIRE = APPLICANT = ASSESSOR = CM -STATUS: ISSUED BLD20181089 CONDITIONS • Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309 • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check thejob card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. Approval of any plat or plan containing provisions which do not comply with city code and forwhich a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. Sound/Noise originating from temporary construction s ites as a result of construction activity are exempt fi-orn the noise limits of ECC Chapter 5.30 only during the hours of 7:00arn to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with tile noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harinless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly ftomthe issuance fdrthis permit. Issuance of this perrilit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. • Final Locations of illuminated exit signs & emergency lighting subject to field inspection by the Fire Marshal. • Request final Fire Department Inspection (425),775-0215. • Nothing in this permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless ofwhether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCT'ION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) VALL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING ENGINEERING (426) 771-0220 EXT. 1326 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you FIRE (425) 775-7720 3. Then: Perm its/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for PUBLIC WORKS (426) 771-0235 5: If you don't ha\e one already, create a assistance dudng office hours. login (upper dght hand corner) (425) 771-0220 RECYCLING (425) 275-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer moming or afternoon. • B-Preconstruction meeting • B-Accessible Ramp/Landings • B-Ceiling Grid/Soffit Bracing • BFraming-Accessibility Provisions • B-Energy-Lighting/Energy Credits • B-Building Final • F-Fire Final BUILDING PERMIT APPLICATION Development Services Building Division 121 5th Ave N / Edmonds, WA 98020 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling informaton go to: http://www.edmondswa.gov/ JOB SITE INFORMATIONAOCATION: (where the work is taking place) Job Site Address: 401 maih 0S*ee+ Parcel: 00!t34+06 -700 060 Lot /Uri #: I- Subdivision: PROPERTY OWNER: Name: lummd 5 W W, 14& AM Mailing Address: 3071 U41 46tywf City/State/Zip: MMA WA q 16 24 Phone #: Email: e4wif OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? El Yes U1110" I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT/ CONTACT INFORMATION: Name of Applicant: I&AAAd JA Vil- MailingAddress: W&Wrloe vioyNx"' City/State/Zip: , V1* VP-4+ kh q 5 V I Phone#: (4". veil - 31 (V I E-mail: he,+ GENERAL CONTRACTOR: (if different from applicant) General Contractor: Mailing Address: I Ise; City/State/Zip: A-0 0- Phone #: A4VIA vfid6 E-mail: to I,m WA STATE CONTRACTOR:)& I # (CCB) & EXPIRATION DATE: oi o CITY OF EDMONDS BUSINESS LICENSE #: 7e D Office Use Only TYPE OF PERMIT (Provide El Accessory Structure/ Detached Garage Details on Page 2) E3 Addition El Demolition 0 Mechanical El New Single Family / Duplex 0 Plumbing El Fire Sprinkler El Remodel E3 New Commercial/ Mixed Use 0 Re -Roof El Signs El Tank enant Improvement El Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: 4 77+14'72,0 PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement scl ft: Finish !X Unfinished 0 Ist Floor, sq ft: 2-01 ?! 2nd Floor, sqft: 0-01 Garage/Carport:, sq ft: -00 Deck/Covered Porch/Patio: WOV Other sq ft: .0-00 PROJECT DESCRIPTION WIV Pgpl[k D444 k W"jO4 0tv) P I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: Signature: Dateov-1tic GENERAL COMMERCIAL DATA Occupancy Group(s): § Occupant Load(s): 03 Type(s) of Construction: V_ *4 Fire Sprinklers: YesX No El WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS (New and Relocated) BTUs Gas Elec Other Qty A/C Unit /Compressor Air Handier /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS (New, Relocated or re -piped) Qty QtY Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Toilets Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re-pipedL M BTUs Qty BTUs Qty A/C Unit Outdoor BBQ / Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, Al R VACU U M COU NTS (New, Relocated or re -piped) Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y / N PSCAA Case #: Critical Areas Determination: Study Required 11 Conditional Waiver El Waiver El Fill in Place 0 Fill Material: Removal El Size of Tank (Gallons) Critical Areas Determination: Study Required 1:1 Conditional Waiver El Waiver E) G RADE/F ILL/ EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes El No ED GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. 2015 Washinaton State Enerav Code COMDliance Forms for Commercial Buildinas includina R2. R3. R4 over 3 stories and all RI Revised Nov 2017 Project Info Project Title: Peoples Bank Tenant Improvement --Edmonds Branch Date 8/29/2018 Compliance Applicant Information. Provide contact information for individual who can For Building Department Use forms do not respond to inquiries about compliance form information provided. require a password to Company Name: Peoples Bank Company Address: 201 Main Street, Edmonds, WA 98020 use. Instructional and Applicant Name: Kelli Smith, Dykeman, Inc. (on behalf of Peoples Bank) calculating cells are write - protected. Applicant Phone: 425.259.3161, 1716 West Marine View Drive, Everett, WA Applicant Email: kellis@dykeman.net Project Description 10 New Building 11 Addition 13 Alteration 11 No Lighting Scope I Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System Description [a Interior Lighting Plans Included Interior Lighting Power 0 Building Area Method 10 Space -by -space Method Allowance Method Select method used in project. Interior Lighting Controls 0 All C405.2.1 - C405.2.8 Lighting Controls 0 C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) 0 Additional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the requi . red controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: e No Dwelling Lighting 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Units 0 C406.3 High Efficacy Lighting 0 R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System No exterior lighting in project. Description 11 Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable 13 provisions as a stand alone new construction p roject Refer to Section C502.2.6 for additional - Lighting systems in addition are combined with existing 0 requirements. building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + exisfing-to-remain interior lighting fixture wattage in Proposed Lighting Wattage table in L TG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. . 111' "n 7' OCT Z 9 2018 T ly C(GV)V -a. BUILDING DEPARTMENT CITY OF EDMONDS ,f—. r—%,, 2015 Washinqton State Enerav Code COMDliance Forms for Commercial Buildinas includino R2. R3. R4 over 3 stories and all R1 Revised Nov 2n17 Project Title: Peoples Bank Tenant Improvement --Edmonds Branch I Date 8/29/2018 Change of Space Use Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(l) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced 0 0 Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced 0 0 of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced Lamp and/or ballast replacement only existing total wattage not increased 0 in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power . compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in L TG-INT-BLD, L TG-INT-SPACE or L TG-EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new+ existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be commissioned per C408.3. New wiring installed to serve added fixtures and/or fixtures relocated to new 0 11 0 circuit(s) New or moved lighting panel 11 11 0 Interior space is reconfigured - luminaires unchanged or relocated only 11 I New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2. 1, daylight responsive controls per C405.2.4 and application specific lighting (a No changes are being made to the interior or exterior lighting systems and existing space controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. , _j - "*-,. 2015 Washinaton State Enerav Code Comoliance Forms for Commercial Buildinas includina R2. R3. R4 over 3 stories and all RI Revised Nov 2017 Project Title: Peoples Bank Tenant Improvement --Edmonds Branch Date 8/29/2018 Calculation Area NOTE 9 0 N�w Construction 0 Addition - 0 Addition stand alone + existing 0 Spaces where < 50% Of 0 Spaces wherea 50% of 0 Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) For Building Department Use LPA Calculation Type 0 Standard 0 Additional Efficiency Package Option C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Notel Maximum Allowed Lighting WattageNo"' Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) A1.41, Room 100 Lobby: all other 81 0.720 58 A1.41, Room 101 Lobby: all other 373 0.720 269 A1.41, Room 101.1 Office: Open plan 11.67 415 0.822 341 A1.41, Room 102 Seating area, general 95 0.430 41 A1.41, Room 103 Banking activity area 516 0.810 418 A1.41, Room 104 Office: Open plan 11.67 1040 0.822 855 A1.41, Room 105 Conference/meeting/multipurpose 261 0.980 256 A1.41, Room 105.1 Storage room 38 0.500 19 A1.41, Room 106 Office: Enclosed 107 0.890 95 A1.41, Room 107 Office: Enclosed 106 0.890 94 A1.41, Room 108 Office: Enclosed 110 0.890 98 A1.41, Room 109 Office: Enclosed 138 0.890 123 A1.41, Room 110 Office: Enclosed 125 0.890 ill A1.41, Room 111 Office: Enclosed 176 0.890 157 A1.41, Room 112 Corridor: all other 158 0.530 84 A1.41, Room 113 Lounge/breakroom: all other 97 0.580 56 A1.41, Room 113.1 Storage room 22 0.500 ll A1.41, Room 114 Lounge/breakroom: all other 220 0.580 128 A1.41, Room 115 Corridor: all other 98 0.530 52 A1.41, Room 116 Restroom: all other 108 0.780 84 A1.41, Room 117 Restroom: all other 112 0.780 87 A1.41, Room 118 Storage room 36 0.500 18 A1.41, Room 119 Electrical/mechanical 38 0.760 29 A1.41, Room 120 Lobby: all other 64 0.720 4G A1.41, Room 121 Storage room 50 0.500 25 A1.41, Room 122 Copy/print room 137 0.580 79 A1.41, Room 123 Office: Enclosed 133 0.890 118 A1.41, Room 124 Storage room 78 0.500 39 Total Area Retail Display Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowance from LTG-INT-DISPLAY Allowed Wafts 3792 Proposed Lighting Wattage NOTE 3 Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed A1.41, Room 100 QQ - 6" Dia. Recessed LED Fixture 2 27 54 A1.41, Room 101 DD - 2'x 4'Recessed LED Fixture 4 44 176 RR - LED Luminaire Spotlight 1 25 25 QQ - 6" Dia. Recessed LED Fixture 3 27 81 A1.41, Room 101.1 SS - 6" Recessed LED Wallwasher 1 27 27 DID - 2'x 4'Recessed LED Fixture 4 44 176 A1.41, Room 102 00 - 6" Dia. Recessed LED Fixture 4 27 108 A1.41, Room 103 DD - 2'x 4'Recessed LED Fixture 5 44 220 !P2 - LED Pendant Fixture 3 9 27 ""' . r - , QQ - 6" Dia. Recessed LED Fixture 5 27 135 SS - 6" Recessed LED Wallwasher 2 27 54 A1.41, Room 104 DD - 2'x 4'Recessed LED Fixture 11 44 484 HH - LED Undercabinet Fixture 1 26 26 QQ - 6" Dia. Recessed LED Fixture 8 27 216 RR - LED Luminaire Spotlight 1 25 25 SS - 6" Recessed LED Wallwasher 4 27 108 A1.41, Room 105 P1 - LED Pendant Fixture 1 41 41 QQ - 6" Dia. Recessed LED Fixture a 27 216 A1.41, Room 105.1 QQ - 6" Dia. Recessed LED Fixture 1 27 27 A1.41, Room 106 DD - 2'x 4' Recessed LED Fixture 1 44 44 A1.41, Room 107 DD - 2'x 4' Recessed LED Fixture 1 44 44 A1.41, Room 108 DD - 2'x 4' Recessed LED Fixture 1 44 44 A1.41, Room 109 DD - 2'x 4' Recessed LED Fixture 1 44 44 A1.41, Room 110 DD - 2'x 4' Recessed LED Fixture 1 44 44 A1.41, Room III DD - 2'x 4' Recessed LED Fixture 2 44 88 A1.41, Room 112 DD - 2'x 4' Recessed LED Fixture 3 44 132 A1.41, Room 113 DD - 2'x 4' Recessed LED Fixture 2 44 88 HH - LED Undercabinet Fixture 1 26 26 A1.41, Room 113.1 QQ - 6" Dia. Recessed LED Fixture 1 27 27 A1.41, Room 114 DD - 2'x 4' Recessed LED Fixture 2 44 88 HH - LED Undercabinet Fixture 2 26 52 A1.41, Room 115 QQ - 6" Dia. Recessed LED Fixture 3 27 81 A1.41, Room 116 AA - CFL Decorative Wall Sconce 2 28 56 00 - 6" Dia. Recessed LED Fixture 3 27 81 A1.41, Room 117 AA - CFL Decorative Wall Sconce * 2 28 56 QQ - 6" Dia. Recessed LED Fixture 3 27 81 A1.41, Room 118 LL - Suspended Fluorescent Strip Fixture 1 32 32 A1.41, Room 119 LL - Suspended Fluorescent Strip Fixture 1 32 32 A1.41, Room 120 QQ - 6" Dia. Recessed LED Fixture 2 27 54 A1.41, Room 121 FF - Surface Mounted Fluorescent Fixture 1 32 32 A1.41, Room 122 DD - 2'x 4' Recessed LED Fixture 2 44 88 HH - LED Undercabinet Fixture 2 26 52 A1.41, Room 123 DD - 2'x 4' Recessed LED Fixture 2 44 88 A1.41, Room 124 FF - Surface Mounted Fluorescent Fixture 1 32 32 Proposed Retail Display Lighting from LTG-INT-DISPLAYI Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattsl 3712 _J Interior Lighting Power Allowance COMPLIE:S] Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4. 1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed WattslFixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track1busway systems, enter the larger of the attached luminaire wattage or 50 wattsllineal toot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby ArtlExhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby artlexhibit display fixtures in L TG-INT-DISPLA Y form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502. 1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided in the Maximum Allowed Lighting Wattage table. d. If lighting alteration project includes some building areas or spaces where < 50% of luminaires are replaced, and other areas or spaces where �: 50% of luminaires are replaced, then these areas or spaces may be documented separately. If multiple forms will be completed to demonstrate compliance for the total scope of the alteration project, describe scope covered in form in User Note section. 41;� - �0. PEOPLES BANK EDMONDS Peoples Bank October 19, 2018 Prepared for: Dykeman Architects STRUCTURAL CALCULATIONS Permit Response Submittal Prepared By: Randy Loveless, P.E. Paul Crocker, P.E, S.E. I ReidfVliddl:eto]n 728 134th Street SW, Sutte 200 Everett WA 98204 4251741-3800 (Fax 425fl4l-3900) www.reldmiddleton.com File No. 262018.102 OCT 2 9 2018 Wo , A IAOMM -%. . Client Sheet of — ITAV N 1 M Project —7.640MIW405 Design by —)ZU=- Date www.reid m idd I eton.com Checked by Project No. Date LO 5 - TJF> L-A �3_-: V��—> F5t= it W NU� it, I—sl (PM 5 01 .0?— OF 15 r6r- 3 F-r -7 (.5 Pu-i= 16 FU �-DACIC> raerL--�� TIOP 1,60 7- A& F = ?Xo C-Op C, scfte;t�) Frr7- W,AeU_ 51-0*0 Comc, 6Cv-Ew 4u616.-*J - 60rrf-r 5QFFOO:;� A4 1 M � V-060S V Wr 2- mw er-r. & 71 S 0 - co G .4 0.1,5 4 j2e kc o --7 ww w. reid mid d I e ton. co rn Client —,P—Ye-f — — - , -- Sheet — of — Project 6140 W00A405 Design by —OU' Date Project No. . --- -- � — Vs 1- 0 0 C1010c'.1 WAIW 0 T- A. tj o r i6-1W 6f C- eM c- Ives Xq /< C, */� a. 1-7 1 o� two) 2 C,,P 10 v /.5c ,:Sc TSK��ZSILCIQ Cx_IIrF)AC-kIAA SOO (.,E> A) 4T, �;20 Checked by Date .. ... EWUIVV - I I Em ww w, reidm i dd I eto n. corn Client Project Project No. - - pl� . . Sheet - of Design by Date Checked by Date -'M? r6o'T TWX- como 9 PA-9-11-Ro �J AJ#UJS (7-OP COtW At-5b) o cAsci�- o, 13 eP D(A �- 3/4 *' i4t un x - �, s z Pe 7*H CO n C(�ek e ?Cf 640&LkL�) 40 14 0"1 L t� S FE��O �3 ................................ L-O&DS (? CC-IL,10G% cuoup-5 A-;>56mr, 6YP,& rMtnlAJ6 (,je(c-,i+5 16 p,51= I I f t, APT G& (IA �-A � " P VJ -7,-Z-5 ?I* AM T5 10 p 1* t-tS t b I (wij.g�ew# n ve�- 5110 Tk"kz (Fm!, 0C. 1.5 O(L 01--f A�oTuSr- cPw-4ciS- �OQ�X, �-OcATIL-)PS As rzeGotwa-z� (b A-%)olD FO-5T-T�C-N-OLON(t,364 5TRA+XD:5 lt'J &K-1511�JG 5LPS. DO "T -fWlJel— lV-plE5-: Sk(tMo(:� bL'ftD k-okT"-WTA"oC44Tl�)('5t Po.5T--T.VrmSLwjAjq bTlT2-JlWV!51 Fkat)T- - .- . - � � 'f 11 vev tilu I )(-C A Fb!5T - TEAYU 00ft 6CA-0-26 LOOR/DECK MON IN TRACKj Aocvc(-� vjp&(, - Wf"LL vipl-6viE6 PLAN I-t> Per-L- vr-4� Tw A2 TYP. NON -BEARING PARTITION 3" = 1 1-011 (r-oom A110) 0- 1 � Client Sheet - of kvi m n i m, RM Project Design by Date — 1 -Q-- LE 3 --( 8— www.reidmiddleton.com Checked by - PM C Project No. Date I Q. 18, ia + 16 x ,X 4 (I oil P /A x 4 112 I KL M :5 C*e 5 3/uv� D kA X t 112. 6 , K,709C> rA-rc-Om (PAM6 6e�,C-7 ^Jorls -t t>-r W d C-Omc, 45,E6 M IL X- 2 x- ZP4 of-&ft Atia(,6 Ar f;�V-A-cc I-Oc L-X, M4-Y� T-0 t (w-c> ert--t i:5 -n x3di 6L49-6 't-0 ("+lbL7r Aps-r - iv�jstow tA-) a ��rm,#jo i 2 3 4 5 D DYKEMAN ARCHITECI-URE DESIGN Peoplo%s 7 (a�-�nk Edrnonds ,161 (T) 2 1 1—, , WA 98201 CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE L REGISTRATION STAMPS: LSD . C 973 9 REGISTERED ARCHITECT '�JW� C 6R2 T- 7 K. GAIR INER SMITH STATE OF WASHINGTON A NEW BRANCH BANK FOR 10 0 Peoples Bank EJ AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 B This drawing Is: 1. Copyright 2017 Dykeman, Inc. 2 The Architect's Instrument of Professional Service. For use on this project only. Obtain Architects written permission for any other use or reproduction. PROJECT NUMBER: AN1,1111) BY PLANNING zL 2016-030 A APPR IRE DF All changes in plans and field modifications Shall be approved by q �'J 0 N ox MARK DATE DESCRIPTION the local jurisdiction. The design profess ional shall prepare drawings as Nothing in this permit approval required for approval. process shall be interpreted as allowing or permitting the IBC 107.4 CITY OF EDMONDS. BUILDING DEPARTMENT maintenance of any currently existing illegal, n.nemifearning, or WORK 3:7= PROJECT TEAM: unpormitted building, or city Of8ftionds #40n ADDRESS e141— PRINC LIN CHARGE:� K.S. 'IPA isstructure, site condition which outside the OWNER ANAGER.,, PROJECT TEAM Scope of the permit application, regard ess of whether such building, I R, 0 V E D, APPROVED DATE: —PROJECT ,�IH T , PROJECTAR E �T K.S. JOB CAPTAIN: A.0. structu re, or c diti h wn on the on on is s 0 BLDG. OFFICIAL: 71 -1 . site plan or drarwing. Such building, ­—V A structure, or condition may be the subject of a separate enforcement PERMIT NIUR BER Client Architect Contractor action. Dykeman GaI Construction, INC. 011 V ;'�` R, .1 7 ? Cover Sheet Peoples Ban P.O. BOX 233 Lynden, WA. 1716 West Marine View Drive Everett, WA 98201-2098 8105 Broadway Everett, WA 98203 GONSTRUCTION TYPE PLANS MUST 02 CM (c DRAWING NUMBER: Contact: Tera Swan Contact: Kalil Smith Contact: Joe Gaffney OCCUPANCY GROUP OF), Y Phone: F ax: Email: (360) 354 7243 Phone: (425) 2593161 (360) 354 7242 Fax, (425) 259 5242 tera.swan@peoplesbank-wa.com Enna'll: kellis@dykeman.net Phone: (425) 355-5500 Fax: (425) 355-4433 Email: joe@gaffneyconstruction.com OCCUPANT LOAD —72 Ob Electrical Permit from 0 S t, Labol & Industries state LaborT -1 OCT 29 2013 1 1 2 3 4 8 U& 5 ,D1NCD1!QAFITM IF, ,PT 1 1 2 3 - ARCHITECTURAL ABBREVIATIONS SYMBOLSLEGEND GENERALNOTES 1, CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT. z ANGLE ..'in An'dw 2. DO NOT SCALE THESE DRAWINGS. DUE TO REPROGRAPHIC PROCESSES THESE & AND L. LENGTH DRAWINGS MAY NOT BE TO SCALE. CONTACT ARCHITECT FOR ANY NEEDED AS ANCHOR BOLT LAV LAVATORY CLARIFICATION. ACT ACOUSTICAL CEILING TILE LB LAG BOLT NORTH ADD A.F.F. ADDENDUM ABOVE FINISH FLOOR UKR LS LOCKER LANDSCAPING - - - - - - - - - - - - - - - - - - - - - - 3. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL - - DISCREPANCIES TO THE ARCH MIECT BEFORE PROCEEDING WITH THE WORK. ALS AREA LIGHT STANDARD ILVR LOUVER Dimensional Control ALUM ALUMINUM I 4. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF THE ANOD ANODIZED MATIL MATERIAL WORK AS INDICATED ON ALL DRAWINGS AND SPECIFICATIONS. IF MAX MAXIMUM + Odd DISCREPANCIES IN LAYOUT, DIMENSIONS, OR DETAILS ARE FOUND BETWEEN BC BOTTOM OF CURB MB MARKERBOARD ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL OR BID BOARD MECH MECHANICAL LANDSCAPE DRAWINGS, CONTACT THE ARCHITECT IMMEDIATELY FOR BLDG BUILDING MED MEDIUM CLARIFICATION BEFORE PROCEEDING. BLKG BLOCKING MEZZ MEZZANINE I B.M. BENCH MARK MFR MANUFACTURER 5. REGULATIONS, STANDARDS, CONSTRUCTION, MATERIALS AND REQUIREMENTS BM 13EAM MH MANHOLE FOR INSTALLATION OF MATERIALS SHALL CONFORM AND BE GOVERNED BY THE BOT BOTTOM M MINIMUM Name EDITION OF THE CODE IDENTIFIED IN THE CODES SHEET OF THESE DRAWINGS. BTU BTWN BRITISH THERMAL UNIT BETWEEN R M:N MISC M FROR MISCELLANEOUS Level Datum Elevation 6. REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES N07 LIMIT MTD MOUNTED APPLICATION FOR DRAWINGS OR DETAILS. C CHANNEL MTL METAL Centerline Mark CS CCTV CATCH BASIN CLOSED CIRCUIT TV NA NOT APPLICABLE 7. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS ARE FOR GENERAL INFORMATION AND CONVENIENCE OF THE CONTRACTOR CG CORNER GUARD NIC NOT IN CONTRACT AND ARE REFERENCED IN ADDITION TO MATERIALS AND FINISHES INDICATED C.I.P. CAST IN PLACE NOM NOMINAL + Spot Elevation - Crosshair OR SPECIFIED ELSEWHERE IN THE DOCUMENTS. CLG CEILING NIS NELSON STUD CLR CLEAR NITS NOT TO SCALE S. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED SLAB WHERE INDICATED. OR Ci CONTROL JOINT Spot Elevation - Target Filled RELATIVE TO DATUM NOTED ON THE DRAWINGS. CMU CONCRETE MASONRY UNIT CA OVERALL CONT CONTINUOUS OC ON CENTER 9. N.I.C. EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS. CONTRACTOR IS CORR CORRIDOR O.D. OVERFLOW DRAIN Location & Label RESPONSIBLE FOR COORDINATION INSTALLATION AND PERFORMING WORK AS CS.J CONSTRUCTION JOINT OD OUTSIDE DIAMETER REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT INSTALLATION. CSMT CASEMENT OFC1 OWNER FURNISHED CONTRACTOR CT CERAMICTILE INSTALLED 10. F.O.I.C. EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF THIS CTR CENTER OFOI OWNER FURNISHED OWNER - - - - - - - - - - - - - - - - - - - - - - - - - WORK. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK AS CENTERLINE INSTALLED Drawing Cal Types REQUIRED FOR INSTALLATION. OH OVERHEAD DBIL DOUBLE OPNG OPENING 1B Exterior Elevation Callout 11. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS FOR FIRE RATED DTL DETAIL OPP OPPOSITE WALLS, INCLUDING, BUT NOT LIMITED TO PIPING, DUCT, CONDUIT, ETC. WITH DF DRINKING FOUNTAIN CIS OUTSIDE FIRE STOPPING PER CODES THAT GOVERN THIS SET OF DOCUMENTS. DIA DIAMETER D DIAGONAL PIP POURED IN PLACE 1A 12. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER D:AG M D ENSION PIL PROPERTY LINE MEMBRANE AT THE FLOOR SLAB, WALLS, AND ROOF. BACKER ROD, SEALANT DISP DISPENSER PLAS PLASTER AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND ALL ON DOWN PLYWD PLYWOOD 1 D 1 B Interior Elevation Callout EXTERIOR DOORS AND WINDOW PENETRATIONS AND OTHER AREAS OF D DAMPROOFING PSIF PER SQUARE FOOT POTENTIAL AIR INFILTRATION, INCLUDING STRUCTURAL, MECHANICAL AND DPR DOOR P.T. PRESSURE TREATED ELECTRICAL PENETRATIONS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE DS DOWN SPOUT PVMT PAVEMENT 11C TO VAPOR BARRIER, OR REPLACE THEM PRIOR TO COVER, AS APPROVED. DT DWG DRAIN TILE DRAWING R. RADIUS Drawing Reference 1 /A101 13. THERMAL AND SOUND INSULATION IS INTENDED TO PROVIDE A CONTINUOUS RD. ROOF DRAIN ENVELOPE AS INDICATED. EA EACH REF REFERENCE EF EXHAUSTFAN REFR REFRIGERATOR Sim 14. ALL ADA TOILETS, URINALS, AND STALLS SHAUL MEET THE REQUIREMENTS OF EJ EL EXPANSION JOINT ELEVATION REQ'D REV REQUIRED REVISE OR REVISION Callout THE CODES THAT GOVERN THIS SET OF DOCUMENTS. ALL STANDARD (NOW ADA) TO LETS SHALL BE CENTERED IN STALLS OR PARTITIONS AS APPLICABLE, ELE C ELECTRICAL RM ROOM UNUESSIOTHERWISE NOTED. E i O.S. EDGE OF SLAB R.O. ROUGH OPENING ENGR ENGINEER POP REFLECTED CEILING PLAN 15. WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDINGS, THEY EP ELECTRICAL PANEL SHALL BE SLOPED AWAY FROM THE BUILDING AS NOTED, BUT IN NO CASE LESS EQ EQUAL SB SMARTBOARD M THAN.125'/12'. EQUIP EQUIPMENT sc SOLID CORE Building Section ES EACH SIDE SECT SECTION 16. MAINTAIN NOTED SLAB THICKNESS AT ALL RECESSED SLAB AREAS AND EW EACH WAY SF SQUAREFOOT SLOPING SLABS. EXST EXISTING SHTG SHEATHING (E) EXPANSION SHWR SHOWER 17. ALL FOAM PLASTIC INSULATION TO COMPLY WITH THE SURFACE BURNING EXT EXTERIOR BHT SHEET Sim CHARACTERISTICS DEFINED BY THE CODE THAT GOVERNS THIS SET OF FA FIRE ALARM SIM si S MILAR A SEISMIC JOINT Wall Section DOCUMENTS. FBO FURNISHED BY OTHERS SM SHEET METAL 18. SPECIAL INSPECTIONS SHALL BE PROVIDED AS REQUIRED BY THE FD FLOOR DRAIN SPEC SPECIFICATION JURISDICTION THAT GOVERNS THIS SET OF DOCUMENTS. FDN FOUNDATION So SQUARE FE FIRE EXTINGUISHER ss STAINLESS STEEL 19. IT SHALL BE THE SPECIFIC DUTY AND RESPONSIBILITY OF EACH TRADE AND FED F RE EXTINGUISHER CABINET STD STANDARD Sim SUPPLIER TO EXAMINE ALL PROJECT DRAWINGS, DETAILS AND FF FINISH FLOOR STIL STEEL EMISSION Detail Section SPECIFICATIONS, AND TO PROVIDE AND FURNISH PROPER EQUIPMENT, FIFE FIN SH FLOOR ELEVATION STOR STORAGE HARDWARE, FI TURES, MATERIALS, ETC., PERTAINING TO THEIR PART OF THE FIN FINISH STRCTSTRUCTURAL WORK SHOWNXCR LISTED IN ANY PART OF THESE DOCUMENTS. QUALITY FIL FLOOR SUBP SUSPENDED - - - - - - - - - - - - - - - - - - - - - - - - - CONTROL, ADVERSE MATERIAL REACTIONS, AND COMPLIANCE TO INDUSTRY FO FACE OF Building Element Tags STANDARD WORKMANSHIP ARE THE RESPONSIBILITY OF THE CONTRACTOR. FOC FACE OF CONCRETE T TEMPERED GLAZING SCHEDULES ARE FOR THE CONVENIENCE OF THE CONTRACTOR TO ASSIST FOR FACE OF FINISH TC TOP OF CURB 00 0@0.00 Keynote Reference THEM IN UNDERSTANDING AND CONSTRUCTING THE PROJECT. ANY OMISSIONS FOM FOS FACE OF MASONRY FACE OF STUD TEL T&G TELEPHONE TONGUE AND GROOVE OR CONTRADICTIONS IN THESE DOCUMENTS SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMrMNG A BID. BIDS RECEIVED FRT FIRE RETARDANT TREATED THK THICK SHALL BE CONSIDERED TO INCLUDE ALL ITEMS SHOWN AND/OR SPECIFIED OR FTG FOOTING TJ TOOL JOINT Area name SCHEDULED FOR A COMPLETE PROJECT. THE CONTRACTOR SHALL NOTE THAT FURR FURRING TP TOP OF PAVEMENT Area Name & Square Footage THE WATERPROOFING DETAILS DO NOT ALWAYS REFLECT THE TYR TYPICAL 160 SIF ARCHITECTURAL DETAILS AND ARE INTENDED TO SUPPLEMENT THE GA GALV GAUGE GALVANIZED TOD TOP TOP OF (MATERIAL) TOP OF PARAPET ROOMNAME ARCHITECTURAL DETAILS NOT REPLACE THEM. INSTALLERS ARE TO BE ZL TIF 01111!!!Illli!l!l I I I I )VI 1, l I 1� GB GRABBAR TOS TOP OF STRUCTURE Room Name & Number E-1017 PER Rill il 'Ir GC GIL GENERALCONTRACTOR GLASS UNFIN UNFINISHED 20. INT RIOR DIMENSIONS ik E TO THE Fi CE OF FINISH AT FRAME WALLS, AND TO THE CENTERLINE OF GRID OR COLUMNS, UNLESS NOTED OTHERWISE. GND GROUND UNO UNLESS NOTED OTHERWISE F__7 Wall Type GVP GYPSUM VENEER PLASTER GWI3 GYPSUM WALL BOARD via VAPOR BARRIER VERT VERTICAL HB HOSE BIB VEST VESTIBULE c6D Storefront Type HC HANDICAP VFY VERIFY HDWR HARDWARE HM HOLLOW METAL W/ WITH Door Number aEft$U%E4�r SUBMITTALS HW HOTWATER WC WATER CLOSET HVAC HEATING, VENTILATION AND WD WOOD AIR CONDITIONING WIF WIDE FLANGE WindowType 1 . FIRE ALARM AND SMOKE DETECTION SYSTEMS FOR THIS PROJECT IS BIDDER WG WIRE GLASS DESIGN, 0ffFMqRRP SUBMITTAL UNDER SEPARATE PERMIT. DESIGN MUST INSULATION WH WATER HEATER COMPLY WITH THE 2016 BUILDING CODE, NFRA, LOCAL JURISDICTION AND :NSUL NT INTERIOR W/O WITHOUT WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRY. OBTAIN Wp WATERPROOFING Ceiling Elevation from Floor Leval APPROVAL OF DESIGN DRAWINGS FROM AUTHORITY HAVING JURISDICTION JAN JANITOR WT WEIGHT PRIOR TO SUBMITTING TO ARCHITECT FOR REVIEW. JT JOINT JST JOIST Roof Assembly Type 2. FIRE SPRINKLER SYSTEM FOR THIS PROJECT IS BIDDER DESIGN VNIFIll SUBM TTAL UNDER SEPARATE PERMIT. DESIGN MUST COMPLY i;ITH 2015 BUILDING CODE, AND WASHINGTON STATE DEPARTMENT OF LABOR AND WHqD Casework Type INDUSTRY, OBTAIN APPROVAL OF DESIGN DRAWINGS FROM AUTHORITIES HAVING JURISDICTION. Material Mark 3. PLUMBING, HVAC, AND ELECTRICAL COMPONENTS OF THIS PROJECTARE BIDDER DESIGN, 09*WtRWSUBMrrrAL UNDER SEPARATE PERMIT. DESIGN INTENT IS AS SHOWN ON THE DRAWINGS THE CONTRACTOR IS - - - - - - - - - - - - - - - - - - - - - - - - - RESPONSIBLE FOR PROVING AN OPERATONAL SYSTEM THAT COMPLAINS Revisions V,4TH ALL REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. ALL PLUMBING, HVAC, AND ELECTRICAL ROUG-1-IN WORK SHALL BE CONCEALED. CA. JIssuedtip ReAsionNumber 4 SIGNAGE DRAWINGS WILL BE SUBMITTED WPERATELY FOR SIGN PERMIT. I - - - 4 BUILDING CODE INFORMATION: PROJECT DESCRIPTION: 5,298 SF TENANT IMPROVEMENT FOR RETAIL BANK BRANCH. CONSTRUCT10N TYPE: V-A OCCUPANCY TYPE: B' BUSINESS FIRE PROTECTION: SPRINKLED (FULLY) FIRE ALARM SYSTEM PROVIDED PROJECTAREA: 5,298 S.F. NUMBER OF EMPLOYEES: 17 OCCUPANT LOAD: T IF rw- -f-- 0 1 BUSINESS AREA - 4,729 SF / 100 SIF (IBC Table 1004.1.2) = cc ASSEMBLY UNCONCENTRATED Yt CONFERENCE ROOM #105 - 259 SF 115 SF (IBC Table 1004.1.2) = ?rOCC ASSEMBLY CONCENTRATED WAITING#1102 - 94 SF 1 7 SF (IBC Table 1004.1.2) = �-4100C LUNCH ROOM #114 - 216 SF = 0 OCC* TOTAL -?WqOCCUPANTS * APPROVAL GRANTED BY THE BUILDING OFFICIAL TO REDUCE THE CALCULATED OCCUPANT AREA PER ISC 10041.2 IN CONSIDERATION OF THE USE OF SPACE #114 LUNCH ROOM BY THE EMPLOYEES ALREADY ACCOUNTED FOR ELSEWHERE. 5 VICINITY MAP PROPERTY INFORMATION BASED ON B OCCUPANCY: REQUIRED WC: I PER 25 FOR FIRST 50, AND 1 PER 50 FOR PARCEL NUMBER: 00434400700800 REMAINDER EXIDING 80 (M) (F) - PER IBC TABLE 2902.1 REQUIRED LAVRATORIES: 1 PER 40 FOR FIRST 80 AND 1 PER 80 FOR REMINDER EXIEEDING 80 M) (F) -PER IBC TABLE J29D2.1 ADDRESS: 201MAINSTREET 37-c-; 37.5- EDMONDS, WA. 98020 PROVIDED: 7 ?.4rl 2 =An M 3W.5 F MALE: 2WC-1 LAVS .OAL && -A FEMALE: 2 WC + 1 LAVS HEATINGSYSTEM� MECHANICALLY HEATED. COOLED AND VENTILATED USING GAS -FIRED UNITS PROVIDED BY BUILDING OWNER TO TENANTSPACE. ENERGY CODE NOTES: 1. THIS PROJECT SHALL MEET THE REQUIRMENTS OF WSEC C4DS BY PROVIDING MORE EFFICIENT WAG AND FAN PERFORMANCE, PER C406.2 AND BY PROVIDING A DEDICATED OUTDOOR AIR SYSTEM IN ACCORDANCE WITH C406.6. THE MECHANICAL SYSTEM S BIDDER DESIGNED AND WILL BE SUBMMTEDASA DEFERRED SUBMITTAL BY THE BUILDING OWNER - GOVERNING CODES WAC 51-50 INTERNATIONAL BUILDING CODE, 2015 EDITION WAC 51-52 INTERNATIONAL MECHANICAL CODE. 2015 EDITION WAC 51-64 INTERNATIONAL FIRE CODE, 2015 EDITION WAC 51-57 UNIFORM PLUMBING CODE, 2015 EDITION WAD 51-11 WASHINGTON STATE ENERGY CODE, 2015 EDITION NATIONAL ELECTRIC CODE, 2014 EDITION NFPA STANDARDS 72,13, Sool ICC A`117.1.X�WACCESSIBUE AND USEABLE BUILDINGS AND FACILIES EDMONDS COMMUNITY DEVELOPMENT CODE TITLE 19 ZONING CODE INFORMATION - ZONE* BD-2 DOWNTOWN MIXED COMMERCIAL USE: FINANCIAL (BANK) DRAWING INDEX - GENERAL G01 Cover Sheet G02 Project Information SITE SD1.0' Site plan ARCHITECTURAL-� A1.00 Wall Types A1.11 Floor Plan A1.12 Floor Finish Plan Al. 13 Equipment Plan A1.14 Power -Data Plan A1.15 Security Plan A1.311 Furnishing Plan Al.41 Reflected Ceiling Plan A3.20 Wall, Ramp Sections A4.1 0 Enlarged Plans & Elevations A4.11 Enlarged Plans - Casework A6.00 Interior Model Views A6.10 Mounting Height, Wall, Floor Finishes Legends A6.11 Interior Elevations A6. 12 Interior Elevations A6.13 Interior Elevations A6.14 Interior Elevations A6.15 Interior Elevations A6.16 Interior Elevations A7.10 Door Schedule A9.11 0 Interior Details A9.20 Interior Details A9.21 Interior Details REM a, OCT 2 9 2018 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 9739 ll .. �n�."Ecr A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1. Copyright 2017 Dykeman, Inc. 2' The Architect's Instnument of Professional SeNice. 3. For use on this project only. Obtain Architect's written permission for any other use or reproduction. 2016-030 MARK DATE DESCRIPTION PER 1 10129/20181 Permit ReStionse PRINCIPAL IN CHARGE:l K.S. PROJECT MANAGER: I - PROJECT ARCHITECT: I K3. JOB CAPTAIN: I A.0. JF<P Project Information trial 0 2 3 4 ___ 2 3 4 EXISTING EXTERIOR WALLS INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR DYKEMAN ARCHITECTURE + DESIGN ­­dyk­­­ 1716 W_ M­i­ Vi.. Dd­ 425,259 316, �T) 2nd F1­ / E,,,,tt, WA 98201 CONSULTANT: ALL WORK SUBJECT TO FIELD IN'SPECTION FOR CODE COMPLIA ___ MCE REGISTRATION STAMPS: PLAN VIE PLAN VIEW PLAN VI PLAN VI PLAN VIEW PLAN VIEW PLAN VIEW WALLTYPE WALL DATA WALL TYPE INALL DATA WALL TYPE WALL DATA WALL TYPE WALL DATA WALL TYPE TWALL DATA WALL TYPE WALL TYPE WALL DATA 9739 REGISTRED MX.4 EXISTING MASONRY VENEER WALL CX12 EXISTING CONCRETE COLUMN FX4 EXISTING FURRED STUD WALL EX.6 EXISTING FRAMED WALL EX.8 EXISTING FRAMED WALL EX.8 EXISTING FRAMED WALL EX.8 EXISTING FRAMED WALL ARCHITECT AIEILI �IMIH C C 00 00 —10 00 00 10 11 .011,1111 STEEL INTERIOR WALLS PROJECT IDENTIFICATION: INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR A NEW BRANCH 4 1/4" 4 7/8" 5 1/4" 7 1/4" BANK L FOR Peoples Bank 5/8"TYPE "X"G.W.B. PAINT —5/8" TYPE X" G.W.B. PAINT 518" TYPE X" G.W.B. PAINT 518"TYPEW'G.W.B. PAINT AT LIGHT GAUGE STEEL FURRING - DEPTH AS --- J­3 518"METAL TRACK —3 518" METAL TRACK —4" METAL TRACK —6" METAL TRACK 201 Main Street REQUIRED TO MATCH ADJUCENT FRAMING --j----5/8" TYPE'X'G.W.B. PAINT T 5/8"TYPEWG.W.B,PAF1NT Edmonds, WA. 98020 5/8"TYPE"X" G.W.B. PAINT 6/8" IYPE'W'G.W.B. PAINT PERMIT RESUBMITTAL 7_1 10/29/2018 B This dravving is: PLAN VIEW PLAN VIEW PLAN VIEW PLAN VIEW PLAN VIE 1. Copyright 2017 Dykaman, Inc, 2 The Architect's Instrument of Professional Service. WALL TYPE WALL DATA WALL TYPE WALL DATA WALL TYPE _:W TY :::A�P E L DATA WALL TYPE WALL DATA For use on this project only. Obtain Architect's written permission for any other use or reproduction, SFZ.1 FURRED WALL SN.3 FURRED WALL SN.3 STUD WALL SIN.4 �WAL��� STU W LL STUD WALL SN.6 STUD WALL PROJECT NUMBER: 10 10 I 2016-030 MARK DATE DESCRIPTION PER 1 10/2W018 PermitResponse INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR 4118" 41/4' 4 7/8" 71/4" PEI GENERAL NOTE: A. FOR PARTITION ATTACHMENT AT SILL AND TOP PLATE REFER TO DETAILS A2 AND C3 - ONSFIEETA9.20, B. FOR F BRACING ATTACHMENT TO OLIND INSULATION 518"TYPE "X" G.W.B. PAINT EXISTING STRUCTURE REFER TO CEILING DETAILS ON SHEET A9.20 AND A9.21. PROJECT TEAM PRINCIPAL IN CHA RGE:j K,S, —5/8" TYPE "X'G.W.B. PAINT PROJECT MAiiAG ER, PROJECT ARCHITECT., I K.S. 3 I/Z'METAL TRACK 50METAL TRACK "METALTRACK 3518" METAL TRACK 6"METALTRACK JOB CAPTAIN: A.0. A A SOUND INSULATION —SOUND INSULATION —SOUND INSULATION OUND INSULATION /8" TYPE'X"G.W.B. PAINT /8" TYPE'X'G.W.B. PAINT 18" TYPEWG.W.B. PAI 1-5/8TYPE'X'G.W.B. PAINT -----S/V'TYPE "X"GWB. PAINT Wall Types PLAN VIE PLAN VIEW PLAN VIEW_ PLANVIEW PLAN VIM DRAWING NUMBER. WALL TYPE WALL DATA WALLTYPE IWALLDATA WALL TYPE �WALL DATA WALL TYPE WALL DATA WALLTYPE IWALLDATA SFZ.3 FURRED WALL SN.3' ACOUSTICFURRED SN.4 FURRED STUD WALL SN.3 ACOUSTIC STUD WALL SNA ACOUSTIC STUD WALL R 1: U 10 10A WALL I 10A 11A I -9 1 3 4 _61wlyrfw P',AR�TTIAL EXTERIOR ELEVATION 1 114"= V-0" T ENTRY VE (D-_ Floor Plan 118"= 1W, T 2 3 Exterior Elevation Keynote Legend 1. EX%ST:NG SEXTERIOR WALL. 2. T NG TOREFRONT. 3. DASHED LINES INDICATE AREA OF WORK TO ACCOMMODATE BANK EQUIPMENT. 4. N.I.C. PORTLAND CEMENT PLASTER FINISH TO MATCH EXISTING CONCRETE BASE. LINE-UP HORIZONTAL REVEALS WITH BRICK ACCENT BANDS. COORDINATE WITH BUILDING CONTRACTOR. 5. FOIC. NIGHT DEPOSITORY. FIELD VERIFY MOUNTING HEIGHT WITH OWNER. 6. FDIC. AUTOMATIC TELLER MACHINE. FIELD VERIFY MOUNTING HEIGHT WITH OWNER. 7. EXTERIOR LIGHT FIXTURE. REFER TO RCP. 8. EXISTING CANOPY. 9. N.I.C. SIGNAGE. EXACT LOCATION, DESIGN, AND SIZE TO BE PROVIDED BY SIGNAGE CONSULTANT. HALLWAY LUNCH ROOM F I _14 -1 HALLWAY WOMEN 4 ILER — 1 5 GENERAL NOTES - FLOOR PLAN A. FOR WALL TYPES REFER TO SHEET A1.00. B. FOR DOOR AND FRAME TYPES REFER TO SHEET A7 10 C. ALL WALLS TO BE FINISHED SMOOTH (LEVE Z_ A, D. FOR TYPICAL DOOR CLEARANCES REFER T L&TAIjIDSIA7.10, ER . D E. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZe SrK NG AS REQUIRED AT ALL WALL MOUNTED LAVATORIES, DMiNG& UNTAINS, CASEWORK, MIRRORS, HANDRAILS, ETC. REFER TO ARCHITECTURAL INTER OR ELEVATIONS. 10 F. SEE DETAIL SHEET A6.10 FOR TYPICAL MOUNTING HEIGHTS FOR WALL MOUNTED ACCESSORIES AND EQUIPMENT. G. SEE FLOOR FINISH PLANS FOR TRANSITION DETAILS AND THRESHOLDS. H. SEE REFLECTED CEILING PLAN FOR CEILING MOUNTED EQUIPMENT. 1. CONTRACTOR TO VERIFY ALL ADA CLEARANCE REQUIREMENTS AS NOTED ON DETAIL A11A8.10. J. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONAL INFORMATION AND NOTES. K. PROVIDE FIRE EXTINGUISHER (FE) AS LOCATED ON THIS SHEET. TYPE AND SIZE AS DIRECTED BY LOCAL FIRE MARSHAL. L. X-RAY SLAB PRIOR TO MAKING ANY PENETRATIONS INTO EXISTING CONCRETE FLOOR SLABS. COORDINATE LOCATIONS OF DRILLING OR N. INTERIOR DIMENSIONS ARCTO THE FALE OF FINISH Ar FRAME AIALLS, AND TO THE CENTERLINE OF GRID OR COLUMNS, UNLESS NOTED OTHERWISE. 0. ALL ELECTROMAGNETICALLY LOCKED EGRESS DOORS MUST COMPLY WITH THE FOLLOWING REQUIREMENTS PER (IBC 1010.1.9.9): Is, 1. THE HARDWARE THAT IS AFFIXED TO THE DOOR LEAF HAS OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS. 2, THE HARDWARE IS CAPABLE OF BEING OPERATED WITH ONE HAND. 3. OPERATION OF THE HARDWARE DIRECTLY INTERRUPTS THE POWER TO THE ELECTROMAGNETIC LOCK AND UNLOCKS THE DOOR IMMEDIATELY. 4. LOSS OF POWER TO THE LOCKING SYSTEM AUTOMATICALLY UNLOCKS THE DOOR. 5. WHERE PANIC OR FIRE EXIT HARDWARE IS REQUIRED BY SECTION 1010.1.10, OPERATION OF THE PANIC OR FIRE EXIT HARDWARE ALSO RELEASES THE ELECTROMAGNETIC LOCK. 6. THE LOCKING SYSTEM UNITS SHALL BE LISTED IN ACCORDANCE WITH UL 294. I Keynote Legend I 1�, EXISTING CONCRETE COLUMN - POLISH SMOOTH. 2- WOOD VENEER FACED ARCHITECTURAL CASEWORK. 3. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. 4�_ 24" X 24" MOP SINK. 5-. TWO COMPARTMENT SS. SINK. REFER TO A2/A6.14 FOR ADDITIONAL REQUIREMENTS. 6; FULL SIZE REFRIGERATOR. PER ICC 804.5.6 COMBINATION REFRIGERATOR AND FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE BOTTOM OF THE FREEZER 54" MAX. ABOVE THE FLOOR WHEN THE SHELVES ARE INSTALLED AT THE MAX. HEIGHTS POSSIBLE IN THE COMPARTMENT. 7� WALL MOUNTED SINK - REFER TO Al/A6.10 AND B1, B3, C31A4. &- ELECTRICAL SUB PANEL. 9, MOP AND BROOM HOLDER. 10. MICROWAVE. 11: PROVIDE COLD WATER SUPPLY FOR COFFEE MAKER. COORDINATE LOCATION WITH OWNER. 12: PROVIDE COLD WATER SUPPLY FOR ICE MAKER. 'RS. 13r EXIT PASSAGEWAY - 2-HR FIRE BARRIER PROVIDED BY OTHE lk- ELEVATOR SHAFT - 2-HR FIRE BARRIER PROVIDED BY OTHERS. 15- 1 HR. OCCUPANCY SEPARATION WALL PROVIDED BY OTHERS. P 16: WINDOW SPRINKLER SYSTEM PROVIDED BY OTHERS. 17< ONE COMPARTMENT SINK - REFER TO Al/A6.10 AND C61A6.13. 18. DUAL HEIGHT ADA COMPLIANT DRINKING FOUNTAIN. I NSTANTAN&OUSrTAN KLES SAVATE4W EAIERM94=1_�W CQNTREW-IC7� OR��ERCOtJNTERA(VAL-L—IN&T-AL6kTIC)N. Lvi� 6&­J� P­31,k�il AL - A J A PER 0 4- 8. 16, Scale: 118" = V-0" NORTH' P. 12 0 U 37 CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE �J�NE lS IERED A T CT R Gf �H E KELU GARDINER SMITH L_7� PROJECT IDENTIFICATION: A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1 Copyright 2017 Dykeman, Inc. 2 The Architeers Instrument of Professional Service. 3. For use on this project only. Obtain Architects .r,.n permission for any other use or reproduction. 2016-030 MARK DATE DESCRIPTION PER 1 10/29/2018 Permit Response PROJECT TEAM: PRINCIPAL IN CHARGE:I K.S. PROJECT MANAGER: I - PROJECT ARCHITECT. I K.S. JOB CAPTAIN: I A.D. Floor Plan II 2 3 4 Floor Finish Plan 'Iff, = V-0" 2 3 TT T.RA.E T CONFERENCE TOFFICS OFFICET OFFICE OFFICE T OFFICE T T 4 General Notes - Floor Finishes A ' FLOOR TRANS:TIONS DETAILS-REFERTO SHEETA9.10. B. FLOOR TRANS T DNS SHALL OCCUR AT CENTERLINE OF DOOR TYPICAL UNLESS OTHERWISE NOTED. C. OMIT FLOORING BENEATH BASE CABINETS. D. FLOOR FINISH TYPES - REFER TO MATERIAL LEGEND THIS SHEET. E. UNLESS NOTED OTHERWISE RECESSES AND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT SURFACES. Keynote Legend Key IValue Keynote Text I . MANUAL WINDOW BLINDS - SWF CONTRACT, R8 MANUAL SHADE WITH FACIA, SHEARWEARE 2410 SERIES (3% OPEN), COLOR: V21`24, CHARCOAUCHESTNUT. 2. TRANSITION OF CARPET AT BARN DOORS OCCURS AT FACE OF WALL/DOOR SIDE. Material Legend - Floor Finishes 0 F1 - Carpa E,4(��C6— jio'F2 - Carpet ..IETRODM 11111111114 -all 0411 "1— Ills 1MV111111111 - , F3 -Sh.etV!nyl LUNCH ROOM 114 F4 - LVT FIS - CeramlcTlle f-j;%F, 111YI01 0 m ENUE, F6-WaIkOffMat Em MEN NEW 011li I CCOUNTS F7 - Concrete - Seared OFFICE TELLERWORK ROOM SEE -FINISH MATERIALKEYON SHEET A6.10 FOR PAINT COLORS. 0 4 11' 16, A �RT H RES U [3 CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE REGISTRATION STAMPS: REGISTERED AX ITE�T �jor�� C . KELLI GARDINER SMITH STATE OF WASHINGTON A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street mon s, PERMIT RESUBMITTAL 10/29/2018 eArchitect's Instrument of Professional Service. 3. For use on this project only. Obtain Architeds written pemission for any other use or reproduction. PROJECT NUMBER: g am 61 Is] g MARK DATE DESCRIPTION ___P R �110/29/2018 Peurnit Response PROJECT TEAM: PRINCIPAL IN CHARGE:I K.S. PROJECT MANAGER: I - PROJECT JOB CAPTAIN: I A.0. Floor Finish Plan I 2 3 4 5 BUILDING D CITY OF EPARTm EDIMOWD'NT S VT I Caush S Diebold 271-95 31"D x 40"W x 72"H P 22 Cisco 7960 Standard IP Telephone Cisco 7960 Standard IP Telephone Standard IP Telephone V 2 Coffee Maker Coffee Maker TCR 'I De La Rue Teller Cash Recycler De La Rue Teller Cash Recycler Teller Cash Recycler MS 16 Dell 17 Inch Monitor Dell 17 Monitor With Stand 17" Monitor without stand M 2 Dell 17 Inch Monitor Without Stand Dell 17 Inch Monitor On Arm 17"'MonitDrWthout stand COT 12 Dell OptlPlex 7010 Dell OpflPlex 7010 PC-Uftra Small (USFF) CT 7 Dell OptlPlex 7010 Tawer Dell OpUPlex 7010 Tower Tower CPU ATM I Diebold ATM CS 7750 Diebold ATM 780 Automatic Teller Machine D13 I I Diebold Safe Deposit Box Diebold Safe Deposit Box Safe Deposit Box AHD 1 DleboIcL_NIghLDsposIL2879 DIeboId_NIghLDeposIL2879 F 11 Epson TM-U375 Printer Epson TM-U375 Printer Teller Printer REP I French_Dwr�_RefrIger&t0L1508D RefrIgeratoLFr9nck_Door KT 2 Humascade Sg Keyboard Tray Humascale Sg Keyboard Tray Keyboard and Mouse Tray KM 17 Keyboard and Mouse Keyboard and Mouse Standard KeyboardfMouse MA 2 M2-Low Res, An (modified) M2-Low Res -Arm (modified) Monitor Arm MC 1 Microwave 30" x 16" x 16" FM 1 Ricoh Aficlo MP C4501-Copier-Printer-Fax Ricoh Aficio MP C4501 Copler/Printer/Fax FL Ricoh Aficlo SP 421ON-Laser Printer Ricoh Aficlo SP 42ION Loser Printer Samsunq_�Lmdes�_smartT\�_TelevisiorL._T\Ll3O61 80" ESS30SU 13D led smart tv, 6 series C 17 Sharp Calculator Sharp Calculator Calculator SHIR 2 �7 ShredderrfaL5444 (1) ShredderrfaL5444 (1) TC I Tell Network Cabinet Chatsworth 36"Dx2VWX76"H, 12 30A UR 1 1 UndeLCountaLRefflgeratoLl 1152 Under�_Counter�_Refrigerato�_l 1162 man NOR INEIRE Bill MR IN 01010 NEW ACCOUNTSi i i OFFICE TELLERWORK SHR ROOM R Fl-2-2 -1 Z 'rd --- 1 6J 1 J VA104 L.L. 1V ARE gill HALLWAY Z�� PER QUIET ROOM F-1 1-3 —1 LUNCH ROOM WOMEN NOTE: ALL EQUIPMENT NOTED ON THIS DRAWING IS PROVIDED AND INSTALLED BY OTHERS. UNLESS NOTED OTHERWISE GENERAL CONTRACTOR IS RESPOSIBLE FOR COORDINATING WITH THE OWNER OR THE OWNERS REPRESENTATIVES ON THE INSTALATION REQUIREMENTS OF ALL EQUIPMENT. 0 . 4' v 16 A Equipment Plan 6M !M1110101 mini PER 118- V-01' Scale. 1/8"= 1�0' NORTH A CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE CONIPLUMN211 REGISTRATION STAMPS: A9739 REGISTERED ARCHITECT � C KELLI GARDINER SMITH ,--7= � PROJECT IDENTIRCATION: A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1. Copyright 2017 Dykeman, Inc. 2. The Architects Instrument of Pfafessional Service. 3. For use on this project only. Obtain Archilecfs written permission for any other use or reproduction. PROJECT NUMBER: 2016-030 MARK DATE DESCRIPTION PRINCIPAL IN CHARGE] ER, PROJECT MANAG . PROJECT ARCHITECT: K.S. JOB CAPTAIN: Equipment Plan 2 3 4 1 5 General Notes - POWER - DATA PLAN D A. ALL POWER/ DATA OUTLETS TO BE V-8"A.F.F. TYPICAL, UNLESS OTHERWISE NOTED.. B. COORDINATE ALL FIXTURE LOCATIONS WITH FURNITURE AND C CASEWORK. DO NOT PLACE MORE THAN (2) WORKSTATIONS ON SINGLE CIRCUIT. DYKEMAN D. LABEL ALL RECEPTICELS AND CIRCUITS. E. ALL LOW VOLTAGE CABLING AND DEVICES BY OTHERS, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PROVIDE CONDUIT PATHWAY, ARCHIIECTURE + DESIGN INSTALI-JUNCTION OXES AT ALL 90 DEG. CONDUIT BENDS. IT30 F. X-RAY SLAB PRIOR MAKING ANY PENETRATIONS INTO EXISTING CONCRETE FLOOR SLABS. COORDINATE DRILLING AND SAWCUTTING WITH BUILDING OWNER PRIOR TO PROCEEDING WITH THE WORK. 16 w�"t A" m" vi- D, - G. REFER TO SECURITY PLAN, DRAWING A`1.5 FOR ADDITIONAL 125 259 3161 IT) 2­1 � I.., I Lv-At, WA 98201 REQUIRMENTS. CONSULTANT: ALL WORK SUBJECT TO FIELD KEYNOTE LEGEND: INSPECTION FOR CODE COMPLIANCE 1. DEDICATED OUTLET FOR DISHWASHER. 2. COORDINATE LOCATION OF OUTLET FOR REGISTRATION STAMPS: GARBAGE DISPOSAL IN FIELD. 3. DEDQTED OUTLET FOR COFFEE MAKER 4. DED CATED OUTLET FOR REFRIGERATOR 5. PROVIDE JUNCTION BOX IN CEILING FOR 9739 SIGNAGE. REGISTERED 6. PROVIDE DEDICATED 30 AMP/120V TWISTLOCK ARCHITECT �W. C C CONNECTION TO DATA CABINET. 7. CONDUIT TO DATA CABINET, FIELD VERIFY SIZE. KELU GARDINER SMITH 8. ATM CONDUIT: HOME RUN TO SUB PANEL. 9. PROVIDE DATA CONDUIT TO ATM AND CABLE TO D E DATA ROOM (ACTIVITY TRIP). 10. LOCATE POWER AND DATA RECEPTICLES BELOW TOP DRAWER IN CABINET SPACE. T T TM 1 1 . MOUNT POWER/ELECTRICAL DEVICES IN OFFICE OFFICE OFFICE OFFICE RECESSED BOX. A NEW BRANCH CONFERENCE OFFICE 11117 M 1119 1 0 1 2. RECESSED FLOOR BOX. COORDINATE LOCATION W IN FIELD. BANK :-_r� ­11- _ff 13. LOCATE POWER AND DATA RECEPTACLES IN TOE KICK, �V 14. MUZAK RECEIVER. FOR -jk=- 1 5. DED:CATED OUTLET FOR RECEIVER. 16. DED CATED OUTLET FOR SECURITY MONITORS. OFFICE R ALARM PANEL. Peoples Bank 12 1-CONDUff 18 LCID SCREENS. FIELD VERIFY MOUNTING HEIGHT. S'fORAGE 9 19. PROVIDE 2" CONDUIT TO LCD SCREENS. 105.1 1 qp,7 20. (3) 1" CONDUITS PROVIDED BY OTHERS. AT M-1 IBUI. 201 Main Street --�> IN CMUNI - - - - - - Edmonds, WA. 98020 N - — - — - — - — - — ---- — - OPEN OFFICE PERMIT RESUBMITTAL AND/ It F — — — — Fla-] UP LEGEND - POWER DATA 10/29/2018 TELL R (T This dravAng is: 1. Copyright 2017 Dykernan, Inc. .0913y 101 NIS 10 CLOSEr 112 PER 2. Th Arch! ct's Instrument of Professional Service. - 9'3 GFCI DUPLEX OUTLET 3. Fooruse otrethis project only. Obtain Architeds written permission for any other use or reproduction. ir L 11 Lu QUIET ROOM 1 G. DUPLEX OUTLET (4r:- 4-PLEX OUTLET: 1/2 DUPLEX i ; PROJECT NUMBER: 10Mdb D OLATED GROUND PER LC112 (E)u THERMOST, AT, 41';.A�1.6 POORDINATE 2016 -030 SHREDDER LUNCH ROOM 'D.E' LOCATION V"'T'T� ES WINGS ROO 121 OPEN OFFICE 1 104 TV OUTLET PER Lei D MARK DATE DESCRIPTION IL JUNCTION BOX FOR POWER PER 1 10/21WIT18 Permit Response 1d7 V W v qp Q DVD 17 PER L ELECTRICA AND DATA FLOOR BOX - L�=) RECESSED FLOOR MOUNTED DUPLEX M 115 OUTLET, 4-PORT DATA. OFFICE RK ROOM 15 WOMEN Qf oi�' 2 - PORT DATA VO CE ACCOUNT. FI-01-17 F -12-3] F-12-2] 1 VESTIBULE 4 - PORT DATA VO�CE ELEVATO f-12-0 2 qp ELECTRICAL SUB -PANEL F PROVIDED BY OTHERS PROJECT TEAM: H, up- GD �A WIRELESS ACCESS POINT PRINCIPAL IN CHARGE:1 K.S. PROJECT MANAGER: D� ER�l PROJECT ARCHITECT: —K.S. JOB CAPTAIN: A.G. T_ JANITOR MEN DRAWING TITLE: J4 ____1 F118 Power -Data Plan DRAWING NUMBER: 0 4' 8. Z� Floor Power- Data Plan rA Scale: 1/6'= V-0" PER I NORTH\ mo 2 3 4 2 3 1 4 1 5 General Notes -SECURITY PLAN D A. PROVIDE FOUR -GANG BACKBOX, SINGLE -GANG MUDRING, 31W C TO ABOVE ACCESSIBLE CEILING SPACE AT EACH DEVICE LOCATION, UNLESS NOTED OTHERWISE. B. FOR DEVICES LOCATED OUTSIDE OF BUILDING PROVIDE WEATHERPROOF BACKBOX AND V C BACK TO DATINETWORK ROOM. C. ALL RACEWAYSISLEEVES THROUGH FIRE RATED ASSEMBLES SHALL BE DYKEMAN FIRE -STOPPED WITH APPROVED METHOD/MATERIALS. D. COORDINATE EXACT DEVICE LOCATIONS AND HEIGHTS WITH TERA SWAN ARCHITECTURE + DESIGN (PH #(360) 354-7243. LOCATIONS SHALL BE REVIEWED AND APPROVED PRIOR TO ROUGH -IN COMPLETETION. N AN 1716 W I M�, - Vi,. D,i­ AEaFMS!E! TOR aO! 425.259.3161 (T) 2�d F1 ... / E,,),,tt, WA 98201 PER CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE C D E C CONFERENCE OFFICE OFFICE —110r7 OFFICE OFFICE OFFICE PROJECT IDENTIFICATION: 105 106 1 8 - - - �'Y - - - - - - - -- - h-TY-11 - - - - - - - - - - - - - - - - - - - - A NEW BRANCH 1111WI\ F BANK ENTRY VESTIOU A STORAGE FOR M-1-1 L LEGEND - SECURITY Peoples Bank El 11 D [E] [Ell C [�J KEY PAD [ff� CARD READER AT L 11 li 11 N I - C- 'I OPEN OFFICE UI- DOORLOCK CAMERA - MOUNTED - W'FROM FLOOR a In ree -1 AH C UP F - - - - 11 - U (�) LEVEL OR 6' BELOW FINISH CEILING, VERIFY LOCATION AND HEIGHT Edmonds, WA. 98020 LO 101 HALLWAY WALL MOUNTED ALARM CABIN ET PERMIT RESUBMITTAL B DL M ILQ 7�ECR 1 3 0C PER AMN ALERT LIGHT DVD DVD MONITOR 10/29/2018 @ QUIET ROOM - M0 SB SQUEEZE BUTTON (WIRELESS) TbIs drawing is; 1. Copyright 2017 Dykernan, Inc. 2.TheArchite Instrument of Professional Service. (9) A--REnDER 00 LUNCH ROOM DC DOOR ONTACT 3. For use on t'his project only. Obtain Architwrs written permission for any other use or neproduction. EJ EJ OFFICE I ROOM F 12-1 OPEN OFFICE M MOTION SENSOR PROJECT NUMBER: so A 2016-030 Ic. ALARM E)— Iff C M M PANELAT &-a, F.F.— HALLWAY w0:a&v1d&f19]� 4 1 115 TELLERIWO RK ROOM R MARK DATE DESCRIPTION PER 1 10/291201A Permit Response NEW ACCOUNT4 I F-1-22-1 C @ -1 ug`�H� ,,I. �111qV1777V7-1'1- 'q� PROJECTTEAM: lz --- 118 116 - -- -- -- -- -- I I �.H PRINCIPAL IN CHARGE:l K.S. PROJECT MANAGE �-- - PROJECT AR�H FTECT. K.S. JOB CAPTAIN: A.D. DRAWING TITLE: A Security Plan 0 4' a, 16' Scale: 1/8" V-0" 11 amm NORTH\ 1 1 2 1 3 1 4 5 OCT Z 9 2018 —1—U —VAN I M�N I CITY OF EDMONDS 2 3 4 D I If it If 11 1111 it 11 1111 A D E CONFERENCE OFFICE OFFICE OFFICE OFFICE OFFICE 106 107 1 8 T MuU.10N r T-r AND STORAG --7 WAU. ENTRY VESTIBULE IL N if .01 AHOIATM---il,. F- I F 104 1 LER Eli LOBIB WAJtINQ 03 W 1 2 h 10 CLOSET LL F1 1-3 1-1 -7 0 3-.0. 0. 0, LUNCH RO, ­73 3'. 0. -SKREODER Ej Ej , . ROOM Q) . T 1 121 3� — PER 7 TELLERWORK OFFICE ROOM 123 HALLWAY QUIET ROOM IALLWAY REIISTERID ARGHnEc, KELLI GARDINER SMITH PROJECT IDENTIFICATION: A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE C I 0 4- 8' 16, A, W60um%mmm� PER Scale: 1/8" = T-O" 14 NORTH R 12 IS U 13 1 1 1 3 1 4 1 5 OCT 2 9 201108 SUM CITY OF �O.OTM'11 This drawing iS: 1. Copyright 2017 Dykeman, Inc, 2. The Architeds Instrument of Professional Service. 3. For use on this project only. Obtain Architect's written permission for any other use or reproduction. PROJECT NUMBER: NOTE: 2016-030 THIS DRAWING FOR INFORMATION ONLY. ALL FURNITURE PROVIDED AND INSTALLED BY OTHERS. MARK DATE DESCRIPTION PER 1 10129/2018 Permit Resoonse PROJECTTEAM: PRINCIPAL IN CHARGE:1 KS. PROJECTMANAGEP, I PROJECT ARCHITECT., K.S. JOB CAPTAIN: A.D. DRAWING TITLE: Furnishing Plan i 2 5 D I Ici I B I A Lighting Schedule WTa Type 9 Mark Light Fixture Description Light Fixture Manufacturer Lamps AA S"W x I WH DECORATIVE WALL SCONCE, HEMERA: BEVERLY 28W (1) 28W CFL 35K 28VA WHITE OPAL SATIN SQUARE GLASS BVW-31-CF26-120V SHADE, POLISHED NICKEL FINISH, ADA. Do T X 4'RECESSED LED TROFFER, cEwER COLUMBLA,LCAT-24.35.LW-G-EI). 44W UED4000LUMENS, 44 VA LIMINOUS LENS, COLD ROLLED STEEL U ELL14 FOR EM LIGHTING 3500K HOUSING, (0-10V DIMMING, 90 CRI) WHERE SHOWN _W E2 EXTERIOR WALL MOUNTED FIXTURE, I GARDCO 121-EM LINE LED LED 35K 36 VA TRAPEZOIDAL WEDGE. INTERGAL 121-EP14-32LA-1-1670-NW-UNTV BATTERY BACK-UP, UL WET LISTED FF 4'SURFACE MOUNTED FLUORESCENT DAY-BRITEOW SERIES 32W (2) F32 TS 60 VA WRAPAROUND FIXTURE, PATTERN 12 OW-W-2-32-120-1/2 EB101 ACRYLIC. MAX 14" WIDEWITH FULL STEEL END PLATES HH LED SURFACE MOUNTED UNDER CABINET LUMINII LIG14TING 26W LED 6.5WIFT 26 VA LIGHT 0.5H x VW WITH REMOTE POWER KL-XX-34K-HO-H-F-F­XX SUPPLY — U. 4'HEAVY DUTY FLUORECENT STRIP Vill METALUX 32W (2) F32 T8 59 VA WIRE GUARD ICF-2-32-UNV-EBBI-WG PI THREE - W.L x 6"W x 8"H - LINEAR LIGHTART LED 120V-277V 41W LED Lamp 4000K, 81 41 VA PENDANT IMPUT: 0.10V DIMMING CRI P2 CONTOUR BEVEL 20" DIA. x 15" H LIGHT ART LED LUMENS aOO 9W LED A19 LAMP, E26 9VA . BASE, 3000K. 120V —PENDANT 00 6. RECESSED LED OPEN DOWNILIGHT, LIGHTOLIER 27W (1) 27W LED 35K 27 VA 1500 LUMEN, 3500K, 80 CRI, 0-10V OWLED-27-120-R(ILED-35-K-WD- DIMMING CSS QQs 6" RECESSED LED OPEN DOWNLIGHT, 900 LIGHTOLIER 1101UED- 17W (1) 17W LED 35K 17 VA LUMEN, 3600K, 80 CRI, 0-1 OV DIMMING 09-N-35K-Dl FIR LED LUMINAIRE SOPTLIGHT LSI, VLX 2024-82MB-SA-W 25W LED 25 VA SS WRECESSED LED WALLWASHER DAYBRITE, ONS LED-27-12D-RO 27W LED 27 VA LED 3SK-WN-CSS X1 MOUNTED LED EDGE LIT EXIT LSI INDUSTRIES 3 W VA LIGHT FIXTURE, HOUSING NATURAL EXE-1-GC-A-120-EM �UNIVERSAL ANODIXED AND EXTRUDED LUMINUM, COMPLETELY SELF CONTAINED, CLEAR ACRYLIC PANEL WITH GREEN LETTERS ism L 11 �Zl 10 9. PER Reflected Ceilin Plan -�Teller Area . .... ........... C2 19"= V4, 2 3 EQ Lighting controls shall meet the requirements ofWSEC C405.2, including, but not limited to: All roorns/areas shall have separate manual controls. Occupant sensors are required in all areas unless meeting an exception. e . Daylight wnes, containing more than 2 fixtures zn, �h-ll lk� ­­I� controlled according to section PEF MATERIAL LEGEND - RCP F4�1 2 x 4 ACOUSTIC CEILING TILES F77777­1 GYPSUM BOARD FLUSH WOOD PANELING Ceiling Tag - Ceiling Elevation from Floor Level Open To Structure Above - Paint SEE - FINISH MATERIAL KEY ON SHEET AS.10 FOR PAINT COLORS. DAYLIGHTING ZONE: General Plans Al A CEILING ET LS Tol. ET. PER B� PR.VIDED.EIA..1�a(IRNG,,TAELLSUAS�END DGMA EFERTOTYPICAL CEILING DETAILS SHEE)AI/A9 2 METAL,JOIST SPAN 5 L_R�F 0� C. _9 Ek TO �EDETAILCIIAS9.20 R NON -SUSPENDED GWR C. To T IL Cl 0 M I 0. CEILING AND SOFFIT HEIGHTS ARE FROM FINISHED SI AB UNLESS OTHERWISE NOTED. E . CE:L NG TYPES - REFER TO MATERIAL LEGEND THIS SHEET. F. CE L:NG GRIDS ARE CENTERED UNLESS OTHERWISE NOTED OR DIMENSIONED. CONTRACTOR SHALL FIELD MEASURE SPACE AVAILABLE TO VERIFY LAYOUT. IF MINOR ADJUSTMENTS ARE NECESSARY TO AVOID STRIPS NARROWER THAN 21 OR OTHER CONFLICTS, OBTAIN APPROVAL OF OWNER REPRESENTATIVE BEFORE PROCEEDING. G. DOMESTIC WATER PIPING AND SPRINKLER PIPE NOT SHOWN FOR CLARITY. CONTRACTOR TO COORDINATE INSTALLATION OF THESE ELEMENTS WITH THOSE OF ALL OTHER TRADES. H. WHERE PAINTING OPEN STRUCTURE IS IDENTIFIED, PAINT ALL EXPOSED SYSTEMS THAT ARE VISIBL� COL --1 UNLESS OTHE50064DICAT D ,E ES� or FE 1. CEN : , L IG 1 0 ISE. ILE RA R N E. MTEMTHW&W RO MS100,10f 0).1, la 10a. 104-11B;­AND 120 SHALL BE CONTROL DBYTIME SWITCH PER WSEC C405.2.2, C405.2.2.1. C405.2,2.2, AND C405.2.3. . A A. CONTROLLED RECEPTACLE& CONTROLLED RECEPTACLE SYSTEM SHALL BE BIDDER DESIGNED IN COMPLIANCE WITH SECTION C405.10 OF THE WSEC. THE METHOD OF CONTROLLING RECEPTACLES SHALL BE PROGRAMMABLE TIME -OF - DAY CONTROL. B. ELECTRICAL AND LIGHTING SYSTEMS COMMISSIONING: ELECTRICAL POWER AND LIGHTING SYSTEMS SHALL BE COMMISSIONED BY A CERTIFIED COMMISSIONING PROFESSIONAL PER THE REQUIREMENTS OF SECTION C408 OF THE WSEC. C. ELECTRICAL AND LIGHTING SYSTEMS CLOSE-OUT DOCUMENTATION: PROVIDE PROJECT CLOSE OUT DOCUMENTATION IN COMPLIANCE WITH SECTION C103.6.3 OF THE WSEC, INCLUDING LIGHTING COMPLIANCE FORMS AND CALCULATIONS THAT DOCUMENT ALL INTERIOR AND EXTERIOR LIGHTING AREA AND/OR SURFACE TYPES, LIGHTING POWER ALLOWANCES AND INSTALLED DENSITIES. D. ALL OCCUPANCY SENSORS SHALL BE EQUIPPED WITH A MASTER OVERRIDE SWITCH. E. PROVIDE INDIVIDUAL LIGHTING CONTROL IN ALL OFFICES, CONFERENCE ROOMS, AND ROOMS LESS THAN 300SF. F. ALL LIGHTING SHALL HAVE DIMING CONTROLS. G. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR AUTOMATIC CONTROL AHAL NOT EXCEED THAT WHICH PROVED BY A20 AMPERE CIRCUIT LOADED TO NOT MORE THAN 80% IN COMPLIANCE WITH SECTION C405.2.5 OF THE WSEC. H. EGRESS LIGHTING SHALL BE BIDDER DESIGNED BASED �&INAL FLOOR PLAN(S) AND THE MOST CURRENT (IN FORCE) ISSUE or THE IBC, No LOCAL CODESIORDINANCES. FINAL EGRESS LIGHTING QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTORS FIELD PLACEMENT DETERMINATION. 1. CONTRACTOR S jA VIDE A CQMPE§iW O�EIRAT1114RhaYSTEM AS DESCRIBED SW. -41 " By PH E- T LL T OOMS,� 15WS T7 HA R OD D .11.101, it - A T T IQ SHAL LL E" Y H R' 14N I HALL SPACE CON'T�l OV B E P A ELL - P 0 S Cor Y OLS SHALL B P _X6 IN RSO L . L 11, rWLIGHTRiE NSr1VE 0 T - L ROVIDED OOMS 101.1, 101, - 0 S AND 10&IN ACCORDANCE WITH WSEC C405.2.4. LEGEN - LIGHTING SYMBOLS E�\ PRIMARY DAYLIGHT ZONE = 1470.5 SF MSECONDARY DAYLIGHT ZONE = 238SF NOTE: A. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED DEVICES, HARDWARE, WIRING, ETC. FOR DAYLIGHT RESPONSIVE CONTROLS AS REQUIRED BY THE WASHINGTON STATE ENERGY CODE. KEYNOTE� I . EXTEND SOUND ATTENUATING BATT NSULATION Z - 0" EITHER SIDE OF WALL WHERE NDICATED. 16' r% NORTH' 4 A 2 x 4 RECESSED EMERGENCY LIGHT FIXTURE - (NIGHT LIGHT) PER . - a _111. Do 2 x 4 RECESSED LIGHT FIXTURE LL LINEAR PENDANT LIGHT FIXTURE FF LINEAR PENDANT LIGHT FIXTURE Pi I PENDANT LIGHT FI)XTURE P2 PENDANT LIGHT FIXTURE 2� CON RECESSE EMERGENCY DOWN �OOW. PER LIGHT FIXTURE ( HT G L�IGHTFI. Coe RECESSED DOWN LIGHT FIXTURE AA WALL SCONE LIGHT FIXTURE 0 SS WALLWASHER LIGHT FIXTURE 0 RR SPOTLIGHT LIGHT FIXTURE HH ­=_1 UNDERCABINET LIGHT FIXTURE Z X1 CEILING MOUNTED EXIT LIGHT FIXTURE CEILING SPEAKERS - MUZAK SYSTEM (FURNISHED BY OWNER); CONTRA TO PROVIDE SUASPENDED CABLE PATHWAY FROM SPEAKERS BACK TO SYSTEM HEAD - END (FURNISHED BY OWNER IN DATA/ELECTRICAL ROOM CONCEALED ABOVE CEILING WALL SWITCH - OCCUPANCY SENSOR (SINGLE LOAD CONTROL) WALL SWITCH - OCCUPANCY SENSOR WITH MANUAL ON WALL SWITCH - DIGITAL TIMER LIGHTING CONTROL MASTER OVERRIDE SWITCH R E S U 0 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE REGISTRATION STAMPS: ���DWERETD ARC""E� KELL! GARDINER SMITH 1_�� A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1 ' Copyright 2017 Dykeman, Inc. 2. The Architect's Instrument of Professional Service. 3. For use on this project only. Obtain Architects written permission for any other use or reproduction. qW.1110f, 111 N MIA 61101 1 MARK DATE DESCRIPTION PER 1 110/29120118 Permit Response PROJECTTEAM: PRINCIPAL IN CHARGE:l K.S. PROJECT MANAGER: I - PROJECT ARCHITECT., I K.S. JOB CAPTAIN: I A.D. DRAWING TITLE: -- Reflected Ceiling Plan IDRAWING NUMBER: I C I 81 A I BUILDING DEPARTMENT CITY OF EDMONDS 2 3 4 5 T D 7-L2 e414 - 11 1/4" —(D DYKEMAN ARCHITECTURE + DESIGN 3 1716 W", A�,!- Vi— D,i- �25,259, 316 T) 2,,d Fl— E—tt, WA 98201 1r2" x 2 10 FLAT BAR OPEN TO HANDRAIL ENTRY 8 RY CONSULTANT: BEYOND VESTI 3ULE A LL WORK SUB JECT TO FIELD Level I �OL LO INSPECTION FOR 01 0-i- -Vel OF Or CODE CONIPLIANCE -A i REGISTRATION STAMPS: RAMP SECTION - A WALL SECTION - CC SECTION AT ATM C 21111110 ARG.n,�, C KELU GARDINER SMITH T II�e EI112 General Notes - Building Sections OJECT IDENTIFICATION: 14 1 1w, I B� RAMP INFOR BANK FOR Peoples Bank ....... .......... HALI AN Keynote Legend LUNCH ROOM 149 OPEN TO F 1-12-1 Key AT F-1 1-41 BEYOND e Value Keynote Te)d 201 Main Street ..... I . EXISTING CONCRETE COLUMN. Edmonds, WA. 98020 6 2. EXISTING STRUCTURE. 3 CEILING TYPE PER RCP. Q��evel 1 0 _0,. '7/ 7/ 'h 4: 5. EXISTING EXTERIOR WALL STRUCTURE. EXISTING STOREFRONT. PERMIT RESUBMITTAL P I 6. EXISTING CONCRETE FLOOR, FLOOR FINISH PER PLAN. 10/29/2018 B gi 0P 1112 fi�l 7. RELITE PER PLAN AND INTERIOR ELEVATION. B EXISITING PARKING -1 8. 1/2 x2 1/4" MI HANDRAIL. This draWrg is: 9. TOILET PARTITION. 1. Copyright 2017 Dykeman, Inc. 10. INTERIOR PARTITION PER PLAN. 2. The Architect's instrument of Professional Service. Building Section - AA 11. 2. CASEWORK PER PLAN. LIGHT F XTURE PER RCP. 3. For use on this project only. Obtain Architect's written permission for any other use or reproduction. PROJECT NUMBER: 13. EXISTING CANOPY. 2016-030 Level 2 -14T- MARK DATE DESCRIPTION 11 /4" P OJECT TEAM: OPEN TO BEYOND PRINCIPAL IN CHI K.S. PROJECT MANAG I _ PROJECT ARCHITECT: I K.S. JOB CAPTAIN: A.0. m 11 .1filyff] I � Lem I I I a A I _uwyel Wall, Ramp Sections DRAWING NUMBER: OCT 2 9 2018 2 3 4 _b11A M15ff lam C�> //,///WC2 j z 77 16 __N 7 7 V7-7- MEN #117 - A MEN #117 - B MEN #117 - C TOILET #118 - D _,_��JANITOR#1119-13 1/4"=V-0" (�6)1/4"=V4' C Y'4' I C LTx win r,32'1� rA_3_2_0� Sim C4 ��20 SIM. 11 SN.3 S .3 ENTRY VESTIBULE F-1 0-0-1 DIM 0. SN.6 — — ING REQU­DMI AREA (1)61 "STEPU Al A9.10 I _EDGEOF W-011 \ \ H / I \ 15/ B2 C1 CONFERENCE L105 REQUIRED MIN. ­NGAR� Al Main �Ent F'!1 o go r� P I 4an 1W=1111. Ed k�4>.10 B6 EW va C2 9 WOMEN #116 -A WOMEN #116 -13 WOMEN #116 -C B2 B3 B4 �)WOMEN#1116 D 114" = 1,.. 1/4" = 11 4"= V-0" 1/4"= T-O" L Win— T I - LL PER Floor Plan - Back Door Ramp 1/4' = V-0" — _(D GENERAL NOTES: A, REFER TO SHEET A6_10 FOR FINISH MATERIAL KEY. B. REFER TO Al/A6.10 FOR TYPICAL MOUNTING HEIGHTS. Keynote Legend Key IValue Keynote Text I . EXISTING CONCRETE COLUMN. 2. EXISTING WALL STRUCTURE. 3. LIQUID SOAP DISPENSER WALL MOUNTED. 4. COMBINATION RECESSED PAPER TOWEL DISPENSER / WASTE RECEPTACLE. 5. TOILET TISSUE DISPENSER. 6. SANITARY NAPKIN DISPOSAL UNIT. 7. TOILET SEAT COVER DISPENSER. 8. 1/2 X2 1/4" MTL. HANDRAIL. 9. PAINTED STEEL TOILET PARTITION, FLOOR ANCHORED. 1 0. 24" x 36" MIRROR UNIT. 11. UNDERLAVATORY GUARD. 12. GRAB BAR. 1 3. WALL MOUNTED LAVATORY. 14. TOILET. 15. LIGHT FIXTURE, REFER TO RCP. FIELD VERIFY ' HE 'GH j:��61JN DOM HOLDER D URINAL REFER TO AVA6.10. 19 VENEER FACED A CHITECTURAL WOA CASEWORK - REFER TO DI/A4.11 20. ELECTRICAL SUB -PANEL PROVIDED BY OTHERS. rx 2 2 U 'a CONSULTANT: ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE CON"PLIN1111" R ... 111111 ARCH 'T�T C I;W� KELU GARDINER SMITH I L�7� A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This draydng Is: 1. Copyright 2017 Dykernan, Inc. 2.TheArchftecr InstrurnentolProfessionalService. 3. For use on thi: proect only. Obtin A,hitecVs witten permission for any other use or reproductim. PROJECT NUMBER : 2016-030 M. -_ MARK DATE DESCRIPTION PER 1 1012912018 Permit Response PROJECTTEAM: PRINCIPAL IN CHARGE:I K.S. PROJECT MANAGER: I - PROJECT ARCHITECT.- I K.S. JOB CAPTAIN: I A.O. A Enlarged Plans & Elevations FDR R: 2 3 W Is 2 3 I D I I B 113 W'WOOD VENEER I. LYWOOD OVER 5/8" MTL. STUDS �D Plan - COFFEE BAR Plan - Teller Pod 4 Z-6` MIN. CLEAR MANEUVERING FLOOR AREA COFFEE BAR - SIDE COFFEE BAR - FRONT (D4 T-D" TELLER POD SECTION B-B TELLER POD - SECTION B-B AND C-C 14- = I �0.. Sr - 2 112" TELLER POD SECTION C-C FFEE BAR - SIDE WALL ,-- COFFEE BAR - RAMP WALL I.0 D6 PLI .1E1 Z�1\ (2) LAYERS 5/8" PLYWOOD CABLE CHASE ACCESSPANEL FIELDVERIFY 2--6- -------- --------- TOUCH LATCH PRINTER LOCATION DRAWER PL-3 OVER 3f1V'PLYWOOC 3/4!'PLYWO DRAWER 7"fid A --SI PL-3 OVER 3/4" v -------------- PLYWOOD A --- ----------- -- = ----: - v RESILIENT BASE W;��RPOD SECTION A -A ;:�a� LOBBY 101 - SECTION AT TELLER CASEWORK -- — (1�5)-1 1/2" = 1 -0- ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE CMAPLIPJNCE REGISTRATION STAMPS: C A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This dravving is: 1 ' Copyright 2017 Dykernan, Inc. PER 2 The Architect's Instrument of Professional Service. 3.* For use on this project only. Obtain Architect's Itt." pennission for any other use or reproduction. PROJECT NUMBER: — �v Z� 2016-030 N H\0101 I I J U KOM I MARK DATE DESCRIPTION PER 1 10/2=018 PeRnit ResDonse (5n TELLER POD - 3 -m-o� TELLER POD - 4B *-A'��T�ELLER POD - 4A �2) 1/2— 1111. ��R P 1'. 7 112" Z . 0" T- 2 1/2" Ir 11-0" 2.-0. 1� PER PLAN A- A" ? PROJECTTEAM: --- El,�ER �POD - �1� (A2/��. TELLER POD - 2B PRINCIPAL IN C 3 PROJECT MANAGER: I PROJECT ARCHITECT. I N JOB CAPTAIN: Enlarged Plans - 1K R a,4. Casework EQ EQ T-O" COMPUTER CABINET-FRONITVIEW COMPUTER CABINET - SIDE VIEW FA4��, TELLER POD - 2A TP COMPUTER CA�jkNET Fi ir - v -o- -CA%;F1Iz-=1--O-- v�, L; 0 U j DYKEMAN ARCHITECTURE + DESIGN .,,, dyk ;,, 1 17 16 W t Vi— D,i� 4252593,61 T) � 2�d Fl—, / E,-11, WA 93201 CONSULTANT: REGISTRATION STAMPS: PROJECT IDENTIFICATION: PROJECT NUMBER: REVISIONS: PROJECT TEAM DRAWING TITLE: DRAW 2 4 6 Finish Material Key Material Legend - Interior Elevations D INTERIOR PAINT: PLI DYKEMAN P11 Benjamin Moore - Edgecomb Gray HC-173 P2 8 nj m n Moore - Midsummer Night 2134-20 PL2 I P Sze Moore - Kingsport Gray HC-86 (or TBD) ARCHITECTURE + DESIGN nj:min P'5 a min Moom-Stoneybwk 1566 PL3 ' 13ASE: PER --dyk—­.,,�1 1716 W,,,, M�,H­ Vi— Drw. BI RoPpe-Black-Brovm4' WC11 125�259.3161 IT) 2,,dFI..,/E­­,WA9R20I B2 Sheet Vinyl Coved Base See Floor Finish Plan) WC2 - 111-4 A CID GS: PER CONSULTANT: e �.V W� WC1 W Wood Veneer Pl�y—woodPanel, S�Waln.ed� C3 - PL2 match rchit ctto vid color contral sample to match 1. 1 vd color �to �_. ; .-- __- WC3 Plastic Laminate I PL2 ALL WORK SUBJECT WC4 Vinyl Wallcovering I Innovations - Basics Style: Zenith I Color. W." TO FIELD BPZE-05 Birch Bi SEE - FINISH MATERIAL WOOD TRIM: KEY ON SHEET AB.110 FOR INSPECTION FOR COIDE 0011s'[PLIP'UNGE B2 PAINT COLORS. ST1 - Stain to match veneer PLASTIC LAMINATE: PL1 Wilsonart-4944-38 Casual Linen A,PL2 Wilsonart-4943.ag_ClassicL�W RED P A CT �4� C C Material Legend - Floor Finishes KEU.1 GARDINER SMITH SPEC ALTY COUNTIERTOPS: PER� Q1 - Pentalquartz / BQ940P /Vellum Polished I Y." slab F1 -Carpet PROJECT IDENTIFICATION: Z� FLOO, RE 111111 F2 - Carpet F1 Carpet- rastan Contract/ Style: Humble Luxe KC187 Cc r.,948Gmet F2 Carpet - Karastan Contract / Style: Humble Luxe KC1 87 C20r., 884 Urbane A NEW BRANCH F3 Sheet Vinyl - Armstrong / ColorArt Mediftne Homogenous Sheet / Color. H5308 Rock Dust Mid F3 - Sheet Vinyl BANK F4 LVT-Armstrong-Natural Creations - Mystix / Style: Aria 18"x 18'quarter- turned / Color. Gray Bellie wn FS Porcelain Tile - Daftile / 12'x24"/ Style: Dignitary / Color Superior Taupe F4 - LVT F= FOR DR08 I Unpolished F6 Walk -off Mat - Mannington I Style: Ruffian 11 - 38 w. / Color: Tan Talons 8404 FT-1— I FT Concrete - Sealed F5 - CeramIcTile Peoples Bank F6 We" Off Me' AT 201 Main Street 11 C ... rate - S-lecl Edmonds, WA. 98020 SEE - FINISH MATERIAL KEY ON SHEET A6 10 FOR PAINT COLORS PERMIT RESUBMITTAL 10/29/2018 B B This drawing Is: 1. Copyright 2017 Dykeman, Inc. 2. The Architects Instrument of Professional Service. 3. For use on this project only. Obtain Architecrs .(,tt.n permission for any other use or reproduction. PROJECT NUMBER: 2016-030 MARK DATE DESCRIPTION I.. NOTE: FLUSH CONTROUS TO C9 Q BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. PER 1 10/2912018 Perry0tResporIse WALL HUNG SANITARY SERVICE SINK ACCESSIBLE SOAP DISPENSER COUNTER MOUNTED DOUBLE -PRONG TO LET PAPER ACCESSIBLE STANDARD ACCESSIBLE FLOOR MOP SINK FAUCET SHOWER HEAD SOAP DISPENSER ROBE HOOK STRIP D:SPENSER URINAL URINAL MOUNT WATER CLOSET LAVATORY NAPKIN DISPENSER PROJECTTEAM: 54�'MIN. PRINCIPAL IN CHARGEI K.S. PROJECT MANAGEF!.- ' 12"' 42" MIN, 36"MIN. z 40" 1 24' PROJECT ARCHILCT: R.S. JOB CAPTAIN: A.D. DRAWING TITLE: Mounting Height, Wall, A e V z . S_ SPOUT V5 0 U M" �- '� " I& 'i - Li —I 2! 1! -11' MIN. S. r. T_ 2! IN Floor Finishes Legends L DRAWING NUMBER: WALL HUNG COAT HOOK FIRE GRAB BARS - SIDE GRABBARS-BACK MIRROR MIRROR WITH SHELF MOP/BROOM HOLDER PAPERTOWEL SEATPROTECTOR PAPER TOWEL DISPENSER DISPENSER DISPENSER DRINKING FOUNTAIN E)CrINGUISHER HEIGHT LEGEND SSORIES MOUNTING 2 3 4 2 IDI ANrM Pn WAi IR OPEN OFFICE - D1 OPEN OFFICE - D 9 OPEN OFFICE - C C 4"- T-O" `11�r �"' OPEN OFFICE - A 114-V-01' T Bl L----------- 0 Material Legend - Interior Elevations PLI PL2 PL3 WC1 WC2-PLt WC3-Pr- WC4 81 SEE - FINISH MATERIAL KEY ON SHEETA6.10 FOR B2 PAINT COLORS. _j General Notes - Interior Elevations A. FINISH MATERIAL LEGEND, WALL FINISH MATERIAL KEY - REFER TO SHEET A6 ' 10. B. TYPICAL MOUNTING HIEGHTS - REFER TO SHEET A6.10. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR ALL WALL MOUNTED DEVICES & EQUIPMENT, FIXTURES, CASEWORK AND RAILINGS. D. RECESSES,'IiETURNS, AND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORK AND PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. F. PAINT ALL EXPOSED METAL DUCTS, CONDUIT, PIPING, GRILLES, DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT. G. WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN. H. CEILINGS - REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFORMATION. 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS NOTED OTHERWISE. Keynote Legend Key IValue Keynote Text 1-. EXISTING CONCRETE COLUMN - POLISH SMOOTH. 2. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. 3. WOOD VENEER FACED ARCHITECTURAL CASEWORK. 4. PLASTIC LAMINATE COUNTERTOP. 5. UNDERCOUNTER REFRIGERATOR. 6. MICROWAVE. 7. N.I.C. COFFEE MAKER. 8. FULL SIZE REFRIGERATOR - COMBINATION REFRIGERATOR AND FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE BOTTOM OF THE FREEZER 54�'MAX. ABOVE THE FLOOR WHEN THE SHELVES ARE NSTALLED AT TE MAX. HEIGHTS POSSIBLE N THE COMPARTMENT. 9. UNDERCABINET LIGHT VALANCE. 10. SECURITY MONITOR. 11. TWO COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 _ SECTION 606 1 2. SAFE. 1S. POWER OUTLET, DATA OUTLET, LIGHT SWITCH, SPEAKER CLOCK OR OTHER DEVICE - REFER TO RCP OR POWER -DATA OR SECURITY PLAN AND SPECIFICATION. 14. WOOD VENEER SHORT WALL, REFER TO C2/A9.10. 15. DISHWASHER. 16. OMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERILAVATORY GUARD. 17. FOIC.VIDEO MONITOR. FIELD VERIFY MOUNTING HEIGHT. 18. LIGHT FIXTURE PER RCP. 19. SEMI -RECESSED FIRE EXTINGUISHER. 20. N.I.C. EQUIPMENT PER PLAN. 21. SAFE DEPOSIT BOX. 22. N.1,C. SIGNAGE. FIELD COORDINATE BACKING REQUIREMENTS. 23. ONE COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 24.- 1/2" X 2 112" TL. HANDRAIL. 25. PRINTER/COPIER. 26; VINYL FILM BY OTHERS. 27. DOOR AND RELITE SYSTEM BY OTHERS. 28. PLASTIC LAMINATE BACKSPLASH. 29. 3/4" PLYWOOD BACKBOARD. 30. ADA COMPLIANT DRINKING FOUNTAIN. ALL WORK SUBJECT TO FIELD IMSPECTION rOR CODE COMPLIANCE ��A R 0-1.�'T IERED 4 ARC .. E KELU GARDINER SMITH PROJECT IDENTIFICATIO A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This draing is: 1. Copyright 2017 Dykernan, Inc. 2 ' The Architeers Instrument of Professional Service. 3. For use on this project only. Obtain Architect's written permission for any other use or reproduction. 2016-030 %,A Ri 1010 MARK DATE DESCRIPTION PRINCIPAL IN CHARGE:1 K.S. PROJECT MANAGER: I - PROJECT ARCHITECT: I K.S. JOB CAPTAIN: I A.D. Interior Elevations C A I 'Ej ENTRY VESTIBULE #100 - B ENTRY VESTIBULE #100 - C ENTRY VESTIBULE #100 - D OPEN OFFICE - B ENTRY VESTIBULE #100 - A A " TY VE A5 114" = T-7' (4 (�� nrT 2 4 gnift 2 4 2 3 4 1 5 General Notes - Interior Elevations ANGLED WALLS A. FINISH MATERIAL LEGEND, WALL FINISH MATERIAL KEY - REFER TO SHEET AS.10. D B . TYPICAL MOUNTING HIEGHTS -REFER TO SHEET A6.10. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR ALL WALL MOUNTED DEVICES & EQUIPMENT, FIXTURES, CASEWORK, AND RAIL NGS DYKEMAN D. RECESSES, RETURNS,IAND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORKAND P11 PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. ARCHTECTURF + DESIGN OPEN TO F. PAINTALL EXPOSED METAL DUCTS, CONDUIT, PIPING, GRILLES, >JENTO EY NO Pi 0 BEYOND DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT. G. WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN, H. CEILINGS - REFER TO REFLECTED CEILING PLAN FOR ­dyl . ...... 1716 W­ M,,i,, Vi,. D6- 42�2593161 (T) 2 IFI E­,,tt, WA 98201 ADDITIONAL CEILING INFORMATION. 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS NOTED OTHERWISE, CONSULTANT: L ---]I L WORK SUBJr-CC Keynote Legend TO HELD F1L11,MsPe-_cTIOiN OPEN OFFICE V132 OPEN OFFICE VC2 114- T-0* A� OPEN OFFICE VD2 Key I Valu Keynote Text 1 . EXISTING CONCRETE COLUMN - POLISH FOR GODE CO1V1PLV;,"I­ SMOOTH. 2. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. REGISTRATION STAMPS C�D (A* 3. WOOD VENEER FACED ARCHITECTURAL CASEWORK. 4� PLASTIC LAMINATE COUNTERTOP. 5. UNDERCOUNTER REFRIGERATOR. C 6. MICROWAVE. 7. N.I.C. COFFEE MAKER. OPEN TO 0 8. FULL SIZE REFRIGERATOR - COMBINATION IN BEYOND REFRIGERATOR AND FREEZER SHALL HAVE OPEN TO AT LEAST 50% OF THE FREEZER B EYOND Pi COMPARTMENT SHELVES, INCLUDING THE PROJECT IDENTIFICATION: IINEEEM� BOTTOM OF THE FREEZER 54" MAX ABOVE THE FLOOR WHEN THE SHELVES ARE 0 INSTALLED AT TE MAX. HEIGHTS POSSIBLE IN THE COMPARTMENT. A NEW BRANCH 9. UNDERCABINET LIGHT VALANCE. 10. SECURITY MONITOR. BANK ll. TWO COMPARTMENT SINK COMPLY WITH SECTION CC -Al 17.1 - SECTION 606 FOR (�;,��,�HALLWAY 1#1115 A ;�n� HALLWAY #115 B �',Z�, �HALLWAY #115 C HALLWAY #115 D 114" V-0" 12. SAFE ' 13. POWER OUTLET, DATA OUTLET, LIGHT 114'=1`0" SWITCH, SPEAKER CLOCK OR OTHER Peoples Bank DEVICE - REFER TO RCP OR POWER -DATA OR SECURITY PLAN AND SPECIFICATION. 14. WOOD VENEER SHORT WALL, REFER TO AT C2/A9. 10. 15. DISHWASHER. 201 Main Street 16, OMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERLAVATORY GUARD. Edmonds, WA. 98020 17. FOIC.VIDEO MONITOR. FIELD VERIFY MOUNTING HEIGHT. 18. LIGHT FIXTURE PER RCP. PERMIT RESUBMITTAL 19; SEMI -RECESSED FIRE EXTINGUISHER. PEN T., 20. N.I.C. EQUIPMENT PER PLAN. 10/29/2018 OPEN TO OPEN TO 21. SAFE DEPOSIT BOX. This drawing is: 1. Copyright 2017 Dykeman, Inc. 13EYOND BEYOND 22. N.1,C, SIGNAGE. FIELD COORDINATE / \ BACKING REQUIREMENTS. TYR 0 23. ONE COMPARTMENT SINK COMPLY 2. The Architect's Instrument of Professional Service. TYR 3. For use on this project only. Obtain Architect's WITH SECTION ]CC -Al 17.1 - SECTION 606 written permission for any other use or reproduction. PROJECT NUMBER: 24. 1/2'x 2 1/2" MTL. HANDRAIL. 0 25. PR;NTER/COPIER. 0 0 0 26. V NYL FILM BY OTHERS. 2 . DOOR AND RELITE SYSTEM BY OTHERS. 2016-030 28. PLASTIC LAMINATE BACKSPLASH. 29. 3/4" PLYWOOD BACKBOARD. OPEN OFFICE -TELLER - D 30. ADA COMPLIANT DRINKING FOUNTAIN. OFFICE -TELLER - C MARK DATE DESCRIPTION ANGUEDWALLS Material Legend - Interior Elevations CP F3_021 PL1 13 F_ C11 PL2 IFG) 4 2) (:K) PL3 PRINCIPAL IN CHARGE:I K.S. PROJECTMANAGER: I OPEN TO BEYOND 7 /0/ �P2 PROJECT ARCHITECT., I K.S. 28 OPEN T BEYOND\ BPEN 0 EN TO EYO BPYOND WC11 JOB CAPTAIN: A.D. A OPENTO OT A BEYOND P5 gKNEE 0 0 WC2 - PL4 N KNE 0 EE 3, Interior Elevations E A E Sp C S A SPACE S P C� WC3 - PL2 M 13 W4 b04 WC4 Mar.?A11111110MI1111�01011-1: ,B B1 SEE - FINISH MATERIAL KEY ON SHEETA6.110 FOR OPEN OFFICE -TELLER - A 0�,OPEN OFFICE -TELLER - B B2 PAINT COLORS. 114' = 11-41" R E S U 10 1 1 2 1 3 4 5 OCT Z9 21 3 I r1113 Typ, TYR QUIET ROOM #113 - C QUIET ROOM #113 - D 1/4" - V-0" ­�,­ rf 0 11 CLOSET#113.1-A Ifnimr-M CLOSET#113.1-1 114"= V-Or' CLOSET #113.1 114" . 1 '-W' CLOSET#113.1-D 114" = V-U Q�) C�:) 1 3 1 ki Material Legend - Interior Elevations PL3 General Notes - Interior Elevations A. F INISH MATERIAL LEG END, WALL FINISH MATERIAL K EY - REFER TO SHEET A6.10. B. TYPICAL MOUNTING HIEGHTS - REFER TO SHEET A6.1 0. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR, ALL WALL MOUNTED DEVICES III EQUIPMENT, FIXTURES, CASEWORK, AND RAILINGS. D. RECESSES, RETURNS, AND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORK AND PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. F. PAINT ALL EXPOSED METAL DUCTS, CONDUIT, PIPING, GRILUE,� DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT. G. WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN. H. CE LINGS - REFER TO REFLECTED CEILING PLAN FOR IL ADDITIONAL CEILING INFORMATION. 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS NOTED OTHERWISE. cffz�= B1 SEE - FINISH MATERIAL KEY ON SHEETAI FOR Keynote Legend B2 PAINT COLORS. r Value Keynote Text 1 2 3 4. 6 ' 7. 8. 1_� 9. 'NO LOCKS 1 0. AT CABINETS THIS ROOM STORAGE #105.1 - C QUIET ROOM #113 - A QUIET ROOM #113 - B ­(�Cj �CONFERENCE#105-D STORAGE #105.1 - B (�C 4 �,, CIS �STORAG E #105.1 - A (§C �3 �,,4� 4" = T-O" 5 1/4" = V-O" 1/4" = l'-O" 1, TAG 1/,V' = V-O" C2 114- V-01' = V-0" (�C340EW ACCOUNTS - 131 I/W' = V-0" CONFERENCE #105 -A (OB �2 �,,4" = -,0., 0 0 CONFERENCE #105 - B Q_� CONFERENCE #105 - C B4 (�5)114"= 1'-0" 12. 13. 14. 1 5. 16. 17. 1 8. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. EXISTING CONCRETE COLUMN - POLISH SMOOTH. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. WOOD VENEER FACED ARCHITECTURAL CASEWORK. PLASTIC LAMINATE COUNTERTOP. MICROWAVE. N.1 i C. COFFEE MAKER. FULL SIZE REFRIGERATOR - COMBINATION REFRIGERATOR A D FREEZER SHALL HAVE AT L AST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE BOTTOM OF THE FREEZER 54" MAX. ABOVE THE FLOO.... I ... ... E _11_ NSTALLED AT TE MAX. HEIGHTS POSSIBLE N THE COMPARTMENT. UNDERCABINET LIGHT VALANCE. SECURITY MONITOR. TWO COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 SAFE , POWER OUTLET, DATA OUTLET, LIGHT SWITCH, SPEAKER CLOCK OR OTHER DEVICE - REFER TO RCP OR POWER -DATA OR SECURITY PLAN AND SPECIFICATION. WOOD VENEER SHORT WALL, REFER TO C2/A9.10. DISHWASHER. OMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERLAVATORY GUARD. FOIC.VIDEO MONITOR. FIELD VERIFY MOUNTING HEIGHT. LIGHT FIXTURE PER RCP. SEMI -RECESSED FIRE EXTINGUISHER. N.I.C. EQUIPMENT PER PLAN. SAFE DEPOSIT BOX. N.1,C. SIGNAGE . FIELD COORDINATE BACKING REQUIREMENTS ONE COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 1/2" x 2 1/2" MTL. HANDRAIL. PRINTER/COPIER. VINYL FILM BY OTHERS. DOOR AND RELITE SYSTEM BY OTHERS. PLASTIC LAMINATE BACKSPLASH. 314" PLYWOOD BACKBOARD. ADA COMPLIANT DRINKING FOUNTAIN. ALL WORK SUBJECT TO FIELD IMPECTION rOR CODE CONIPLIfuNCE. 97 �R-ITERII ARCHITECT C E OF WASHINGTON PROJECT IDENTIFICATION: A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1 Copyright 2017 Dykeman, Inc. 2 The Architect's Instrument of Professional Service. 3. For use on this project only. Obtain Architecrs written permission for any other use or reproduction. IRC 2016-030 MARK DATE DESCRIPTION PRINCIPAL IN CHARGE:[ K.S. PROJECT MANAGER: I - PROJECT ARCHITECT: I K.S. JOB CAPTAIN: I A.0. DRAVVING TITLE: Interior Elevations NEWACCOUNTS-A NEW ACCOUNTS - B NEW ACCOUNTS - D NEW ACCOUNTS - C 1/4" = V-0" 1/4" = V-0" (#31/4" = T-O" 3 BUILDIN r R%1jW Ctly a 0 OF rip) TA 40 C�:) CORNER CORNER 0 0 SHREDDER RM. #121 - D SHREDDER RM. #121 - A SHREDDER RM. #121 - B SHREDDER RM. #121 - C ,4� VESTIBULE #120 - C VESTIBULE #11:20 - D 14 �Dl 'V-W 114* = T-V D D C�:) r, �, DATA/ELEC. #119 - C A_� DATA/ELEC. #119 - D VESTIBULE #120 - A VESTIBULE #120 - B DATA/ELEC. #119 - A (���A/ELEC. #119 B(�C�3,41=11�1.�� (�5)1/4" = V-0" (�6)1/4" = V-17" D', AT�l E L �EC. # 1 �19 - I 1/4" = V-0" C2 1/4" - V-0" WORKROOM #122 -A '\,WORKROOM #122 - B 1/4"m V-O' B2 �-114" = 1 -0" *NO LOCKS AT CABINETS THIS ROOM *WORK ROOM #122 _- C B3 1.1.11.1 �, _V M A3 (:K) @� 13 01_�� 0 0 11 B 0 *A WORKROOM #122 - D 1/4" = V-01' General Notes - Interior Elevations A. FINISH MATERIAL LEGEND, WALL FINISH MATERIAL KEY - REFER TO SHEET A6.10. B. TYPICAL MOUNTING HIEGHTS - REFER TO SHEET A6.10. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR ALL WALL MOUNTED DEVICES & EQUIPMENT, FIXTURES, CASEWORK, AND RAILINGS. D. RECESSES, RETURNS, AND PROJECTIONS RECEIVE SAME FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORK AND PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. F. PAINT ALL EXPOSED METAL DUCTS, CONDUIT, PIPING, GRILLES, DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT. G. WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN, H. CEILINGS - REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFORMATION. 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS NOTED OTHERWISE. IKey I Keynote Legend Value Keynote Text EXISTING CONCRETE COLUMN - POLISH SMOOTH. 2. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. 3. WOOD VENEER FACED ARCHITECTURAL CASEWORK. 4. PLASTIC LAMINATE COUNTERTOP. 5. UNDERCOUNTER REFRIGERATOR. 6. MICROWAVE. 7. N.I.C. COFFEE MAKER. 8. FULL SIZE REFRIGERATOR - COMBINATION IC REFIR GERATOR AND FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE BOTTOM OF THE FREEZER 54" MAX. ABOVE THE FLOOR WHEN THE SHELVES ARE NSTALLED AT TE MAX. HEIGHTS POSSIBLE IN THE COMPARTMENT. 9 UNDERCAB IT V INC ITOR. PE 11. COMPARTMENT SINK COMPLY WITH S CTI N IQC-A1 17.1 - SECTION 606 13. POW OUT OUTL T. POWER OUTLET, DATA OUTL T, LIGHT SWITCH, SPEAKER CLOCK OR OTHER DEVICE - REFER TO RCP OR POWER -DATA OR SECURITY PLAN AND SPECIFICATION. 14, WOOD VENEER SHORT WALL, REFER TO C2/A9. 10. 15. DISHWASHER. 16. OMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERLAVATORY GUARD. 117. FOIC.VIDEO MONITOR. FIELD VERIFY MOUNTING HEIGHT. 18. LIGHT FIXTURE PER RCP. 19. SEMI -RECESSED FIRE EXTINGUISHER. 20. N ' I . C. EQUIPMENT PER PLAN. 21. SAFE DEPOSIT BOX. 22. N.I,C. SIGNAGE . FIELD COORDINATE BACKING REQUIREMENTS. 23. ONE COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 24. 1/2" x 2 1/2" MTL. HANDRAIL. 25. PRINTER/COPIER. 26. VINYL FILM By OTHERS. 27. DOOR AND RELITE SYSTEM BY OTHERS. 28. PLASTIC LAMINATE BACKSPLASH. 29. 3/4" PLYWOOD BACKBOARD. 30. ADA COMPLIANT DRINKING FOUNTAIN. Material Legend - Interior Elevations WC11 WC2 - PIL4 W03 - PL2 1114 C77r= BI SEE - FINISH MATERIAL KEY ON SHEET A6.10 FOR B2 PAINT COLORS ALL VVQRI'� SUBjECY TO FIELD , W-SPECIMN, FOR CODE COrv;1P1IJfU1N1,11'_., IREGISTRATION STAMPS: I REGISTERED .G."�CT vj4f�� KELLI GARDINER SMITH srATE OF WASHINGTON A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawi"g is: 1. Copyright 2017 Dykeman, Inc. 2. The Architect's Instrument of Professional Service. 3. For use on this pmject only. Obtain Architect's written permission for any other use or reproduction. IRC 2016-030 MARK DATE DESCRIPTION PER 1 10129/2018 Permit Resoonse PROJECT PRINCIPAL IN CHARGE:1 K.S. PROJECT MANAGER: I - PROJECT ARCHITECT: K.S. JOB CAPTAIN: A.D. Interior Elevations LUNCHROOM#114-A LUNCHROOM#114-B LUNCHROOM #114 -C A� LUNCH ROOM#114- D IM11=1111. (�� 19"= V-0, IM, = T-7, (�� 1/4"= V-0" 2 3 4 Material Legend - Interior Elevations General Notes - Interior Elevations T PLI M A. FINISH MATERIAL LEGEND, WALL FINISH MATERIAL KEY - REFER TO SHEET A6.10. TYR PL2 B. TYPICAL MOUNTING HIEGHTS - REFER TO SHEET A6.10. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR ALL WALL MOUNTED DEVICES & EQUIPMENT, FIXTURES, DYKEMAN CASEWORK AND RAILINGS. TIONS RECEIVE SAME D. RECESSES,'kETURNS, AND PROJEC (2D CORNER PL3 FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORK AND PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. ARCHITECTURE + DESIGN N N f� WC11 F. PAINT ALL EXPOSED METAL DUCTS, CONDUrr, PIPING, GRILLES, DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT. --dyl 176W­W,i­Vi,,D,i­ 81 11� J G� WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN. H. CEILINGS - REFER TO REFLECTED CEILING PLAN FOR 12�52X.3Wl (T) 2,,d Fl..r / E .... tt, WA 98201 CORNER N _4 WC2 - PL4 ADDITIONAL CEILING INFORMATION. 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS WC3 - PI.2 NOTED OTHERWISE. CONSULTANT: ,4� OFFICE #108 - A OFFICE #108 - B OFFICE #108 - C OFFICE #108 - D WC4 ALL VIVOMN' SUBJECT 1W­ V-0" 1/4" 11�0" TO FIELD Bi SEE - FINISH MATERIAL KEYONSHEETA6.10FOR 82 PAINT COLORS. Keynote Legend INSPECMIN FOR CODE 1= Keynote Te)d 1 . EXISTING CONCRETE COLUMN - POLISH � REGISTRATION STAMPS: P11 SMOOTH. 2. MANUFACTURER PLASTIC LAMINATE FACED CABINETS, 3. WOOD VENEER FACED ARCHITECTURAL C C - - --------- ------- --------- 4. PLASTIC LAMINATE COUNTERTOP. 5. UNDERCOUNT R REFRIGERATOR. 6 MICROWAVE. 7' N.1 C. COFFEE MAKER. mazu"l:mm Mq ill I I a Leftlll I 8'. FU'LL SIZE REFRIGERATOR - COMBINATION REFRIGERATOR AND FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE A NEW BRANCH BOTTOM OF THE FREEZER 54" MAX. ABOVE THE FLOOR WHEN THE SHELVES ARE BANK INSTALLED AT TE MAX. HEIGHTS POSSIBLE IN THE COMPARTMENT. 9. UNDERCABINET LIGHT VALANCE. FOR 10. SECURITY MONITOR. OFFICE #107 - A OFFICE #107 - B /4"= T-O" OFFICE #107 C (q3 _A� OFFICE #107 D 11, TWO COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 12. SAFE. Peoples Bank 13. POWER OUTLET, DATA OUTLET, LIGHT Pi SWITCH, SPEAKER CLOCK OR OTHER AT DEVICE - REFER TO RCP OR POWER -DATA OR SECURITY PLAN AND SPECIFICATION. 201 Main Street 14. WOOD VENEER SHORT WALL, REFER TO C21A9. 10. Edmonds, WA. 98020 5. DISHWASHER. 16. OMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERLAVATORY GUARD. PERMIT RESUBMITTAL 20' 17. FOIC.VIDEO MONITOR. FIELD VERIFY 10/29/2018 N MOUNTING HEIGHT. B F 01 1 8. LIGHT FIXTURE PER RCP. 19. SEMI -RECESSED FIRE EXTINGUISHER. This drawing is: 1. Copyright 2017 Dykaman, Inc. 0 20. N.I.C. EQUIPMENT PER PLAN. 21. SAFE DEPOSIT BOX. 2. The Architects Instrument of Professional Service. 3. For use on this project only. Obtain Architect's 22. N.1,C. SIGNAGE. FIELD COORDINATE written permission for any other use or reproduction. PROJECT NUMBER: 0 0 BACKING REQUIREMENTS. 23. ONE COMPARTMENT SINK COMPLY �A 4) SECTION ICC-Al 17.1 - SECTION 606 24. i;;' 2 1/2" MTL. HANDRAIL. 2016-030 4) (i) TYR CB11 25. PRINXTER/COPIER. 26. VI NYL FILM BY OTHERS. 27 . DOOR AND RELITE SYSTEM BY OTHERS. AHD/ATM#124-C AHD ATM #124 D OFFICE #106 A (�3)1/4"= V-0" OFFICE #106 B &r__� OFFICE #106 - C OFFICE #106 D (�6)1/4" 1�.. 28. PLASTIC LAMINATE BACKSPLASH. 29. 3/4" PLYWOOD BACKBOARD. 30. ADA COMPLIANT DRINKING FOUNTAIN. MARK DATE DESCRIPTION PROJECT TEAM. PRINCIPAL IN CHARGE:j K.S. CORNER CORNER CORNER PROJECT MANAGER: I - PROJECT ARCHITECT,. K.S. JOB CAPTAIN: A.0. RE-3 Interior Elevations BI DRAWIN G NUMBER: IFFICE #123 - A OFFICE #123 - B OFFICE #123 - C �11 UE #1 (��_A'� �OFFICE #123 - D ._�AHD/ATM#124-A ��AHD/ATM#1124-13 (�6) R E. 0 U r" 11-0" " 114" = V.0. IW-1'-O" OCT Z 9 2018 1 2 3 4 5 B'q!'w-mDr='w-= 2 3 4 5 Material Legend - Interior Elevations General Notes - Interior Elevations A. FINISH MATERIAL LEGEND, WALL FINISH MATERIAL KEY - REFER TO SHEET A6.10. D PLI B TYP CAL MOUNTING HIEGHTS - REFER TO SHEET A6.10. C. BLOCKING - PROVIDE BLOCKING BEHIND WALL FINISHES FOR ALL WALL MOUNTED DEVICES &EQUIPMENT, FIXTURES, ME PL2 CASEWORK, AND RAILINGS. D. RECESSES, RETURNS, AND PROJECTIONS RECEIVE SAME DYKEMAN FINISH AS ADJACENT SURFACES UNLESS OTHERWISE NOTED. �CMER_ PL3 E. WALL FINISHES MAY BE OMITTED BEHIND CASEWORK AND PERMANENT EQUIPMENT WERE CONCEALED FROM VIEW. F. PAINTALLEXP SED METAL DUCTS, CONDUIT, PIPING, GRILLES, ARCH11FC1URF � I -SIGN EQ OPEN TO BEYOND WC1 DIFFUSERS, AND REGISTERS, ETC. COLOR AS SELECTED BY ARCHITECT . 0 01 G WINDOW SHADE LOCATIONS - REFER TO FLOOR FINISH PLAN. 4252�93161 (T) ),, J 1,� I W1 9,1201 SPOUT r I_F1 LLLJWC2 - PL4 H� CEILINGS - REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFORMATION. I 1. ALL CABINETS AND DRAWERS SHALL BE LOCKING, UNLESS NOTED OTHERWISE. CONSULTANT: WC3 - PL2 131 (k WC4 HALLWAY #112 - C PER HALLWAY #112 D2 - D 81 SEE -FINISH MATERIAL Keynote Legend A, L L W 0 R K 3 U�S- i E 0 T TO FIELD 0.. 114- I'-U' B2 KEY ON,SHEET A6.10 FOR PA NT COLORS. W-SPECMN FOR Keynote Text CODE CCR'APLV'.'W'0."-'. 1. EXISTING CONCRETE COLUMN - POLISH Pi SMOOTH. REGISTRATION STAMPS: 2. MANUFACTURER PLASTIC LAMINATE FACED CABINETS. 3. WOOD VENEER FACED ARCHITECTURAL A CASEWORK. 4. PLASTIC LAMINATE COUNTERTOP. RE"'TEEl C [ 5. UNDERCOUNTER REFRIGERATOR. 6. MICROWAVE. KELLI GARDINER SMITH L_7� 7. N.I.C. C FFEE AKER. OPEN TO 8. FULL SIZE REFRIGERATOR - COMBINATION P 0 EN TO BEYOND BEYOND REFRIGERATOR AND FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES, INCLUDING THE D 13 BOTTOM OF THE FREEZER 54" MAX. ABOVE THE FLOOR WHEN THE SHELVES ARE A NEW BRANCH NSTALLED AT TE MAX. HEIGHTS POSSIBLE N THE COMPARTMENT. BANK 9. UNDERCABINET LIGHT VALANCE. 10. SECURITY MONITOR. FOR 11. TWO COMPARTMENT SINK COMPLY WITH SECTION ICC-Al 17.1 - SECTION 606 OFFICE #111 - D HALLWAY #112 - Al HALLWAY #112 - A2 v-0. A'� HALLWAY #112 - B 12. SAFE. 13. POWER OUTLET. DATA OUTLET, LIGHT SWITCH, SPEAKER CLOCK OR OTHER Peoples Bank DEVICE - REFER TO RCP OR POWER -DATA AT OR SECURITY PLAN AND SPECIFICATION. TYR 14. WOOD VENEER SHORT WALL, REFER TO 201 Main Street C2/A9.1 0. 5. D SHWASHER. 11 Edmonds, WA. 98020 & OIMIT TOE KICK AT SINK CABINET DOOR, PROVIDE UNDERLAVATORY GUARD. 17. FOIC.VIDEO MONITOR. FIELD VERIFY PERMIT RESUBMITTAL MOUNTING HEIGHT. 18. LIGHT F XTURE PER RCP. 10/29/2018 19. SEMI -RECESSED FIRE EXTINGUISHER. 20. N ' I . C. EQUIPMENT PER PLAN. This drawing is: 21. SAFE DEPOSIT BOX. 1. Copyright 2017 Dykeman, Inc. TYR El 22. N.1,C. SIGNAGE. FIELD COORDINATE BACKING REQUIREMENTS. 23. ONE COMPARTMENT SINK COMPLY 2. The Architects Instrument of Professional Seivice. 3. For use on this project only. Obtain Architect's written permission for any other use or reproduction. WITH SECTION ICC-Al 17.1 - SECTION 606 PROJECT NUMBER: 24. 1/2'x 2 1/2" MTL. HANDRAIL. 25 ZNTER/COPIER. 2016-030 26. V NYL FILM BY OTHERS. 27. DOOR AND RELITE SYSTEM BY OTHERS. 28. PLASTIC�6 IN BAC"&LASH. �OFFICE#110-C OFFICE #110 - D OFFICE #111 A _A� OFFICE #111 B OFFICE #111 C Z� PER MARK DATE DESCRIPTION PER 1 10129/2018 Permlt Response TYR PROJECT TEAM: PRINCIPAL IN CHARGE:j K.S. PROJECT MANAGER: CK) PROJECT ARCHITECT: I K.S. JOB CAPTAIN: A.D. A �E-1 A El $3 Interior Elevations CORNER L DRAWING NUMBER: T TYP TYR 1) TYR. C�:) OFFICE #109 - A OFFICE #109 - B A OFFICE #109 - C _A� OFFICE #109 - D OFFICE #110 - A 1/4' OFFICE #110 - B E 3 UP A nrT 7 0 ')rHA,= 2 3 4 5 C 1 1 2 _3 4 11111,1,110 - 111111 1111, 11 00 Ched 11 PULL SIDE Door Width Height Desorption Panel Panel Material Panel Finish Type H Frame Finish Jamb Detail Head ,-Il T Comments is Type I I I D Numbs I ODA S' - 0" T - OP Double Swing FG-2 GUAL Annodizej -.Dark Bronze AL-10 Annodized - Dark Bronze E)dsflng Provided by Building Omer WALL PER PLAN I IOOB - 0" - 0" D ube ng 6 7' L Annodized - Dark Bronze HDW-1 AL-12 Annodized - Dark Bronze C41A7.IO SIM. C41A7.1 0 SOUND ATTENUATING IOSA_ 1, 20;, G' F wo-od - Maple STN HOW r/ WD-B STIN AVA9.21 oia/Ag 21 BATT INSULATION WHERE INDICATED ON DYKEMAN .. Single Swing FG GUAL Annodized - Dark Bronze 4 AL-10 Annodind - Dark Storm Eyjsflng Provided by Building Omer WALL TYPES V-6` 105C_ T - T 7' - 0" Pocket Door I F Wood - Maple STN - 14OWL5- WD-SL STIN D41A7I 0 SIM. 1341ATIOSIM. WALLPERPLAN MIN. ARCHITECTURE + DESIGN 106A 3'- 0" T- 01' Barn Door FG Wood - Glass STN HDW-1, WD-B STIN A3/A9.21 A21A9.21 107A 31 = On 7'. 0" Barn Door - FG Wood - Maple STN HDW-V WD-B STIN A31A9.21 AVA9.21 MTL. STUD HEADER ID IOBA_ T- 0' 7'- 0" Bann Door 109A T- 01' 7'- 0" . Barn Door -6.-r FG Wood - Maple STN KLYW-11 FG Wood - Maple STN HDW-1/ -Maple WD-B WDwB STN A31A9.21 A2/Ag.21 STN A3/A9.21 A2/Ag.21 STIN A3/A9 21 AVAIL21 3M'QUARTER SAWN I MAPLE TRIM. FINISH Nt 1716W­Mz,ri­VimD�i,, 110A V_O`1 71 = On Sam FG Wood - STIN HDW-1,- _N WD-S CLEAR 125259,3,61 (T) 2,d F[... E-tt, WA 98201 111A 3'- 9' r-0- Single Swing FG Wood - Maple ST H-D-W-6 WD- 10 STIN C11A9.1O CIIA9.10 - allSH SI#DE PUSH SIDE 112A_ T- 0" T-O" Single Swing FG GUAL Annodized Dark Bronve AL-10 Armodized - Dark Bronze E)dsUng I Provided by Building Owner WOOD DOOR FRAME. 1131A Y- 0" T- 0" Pocket Door F Wood - Maple STN HDW-5 WD-SL STN D4/A7.1O SIM. D4/A7.1OSIM. STAIN 11 3A TwOm T- 0" Single N" FG Wood - Maple STN HDW-3 WD-00 STN D4/A7.I 0 SIM. D4/A7.1O 1/2" x 1 117WOOD STOP 4" MIN. MIN. CONSULTANT. 115A T- 0' T-O" S� Swing FG Wood - Maple STN HDW-3 WD-00 STN D41A7.I 0 SIM. D41A7.10 DOOR PER SCHEDULE 116A 3- 0" T- 0" Single Swing F Wood - Mapte STN HDW-4 WD-00 STN DQATIOSIM. D41A7.1O D4/A7AOSIM. DQATIO 117A T- 0" 7'- 0" Single Swing F Wood - Maple STN HDW-4 WD,00 STN ALL WORIK SUlliEC T 118A T- 9' T- E� Single Swing F !-I - �MaPIOSTN HDW-4 IWD-00 STN D41A7.1OSIM. D4/A7.1 0 D4/A7.10SIM. D41A7.IO TO FIE D IIM Single Swing T-O" T - 0" 120A S.-O.. T. 0" Double Swing F �_Map,. STN HDW4 Woo :d FC-2 GUAL Annoclized - Dark Brorons GUAL Annodtzed - Dark Bronze HDW-f WD-00 AL-10 AL­`IO STN Annotized - Dark Bronze EAsting I Provided Building Omer Annodized - Dark Bronze C4/A7.1OSIM. G41A7AO WOOD FRAME HEAD/JAMB SIM. TYPICAL DOOR CLEARANCES (�� WSPECTIONP FCjR 120B V-0- 7'.0" Double Swing FG-2 HDW-3 WD--00 D41A7.1OSIM. D4/A7.10 1..0.. CODE COLIPLIANI-7 coc,� _O., 121A T-01' 7- - 0" Single Swing -T2-2A T- D" T_ 0" Single SIving 43'-D" - F Wood - Maple Wee STN W _Me FG Wood - Maple STIN HDW-3 WD-10 STN CIIA9.10 SIM. Cl/Ag.10 123A T- 0" Barn Door FG Wood - Maple STN HDW-l' j WD-B 124A T- 9' T- 9' Single Swing F Wood - Meals STN A 0 C4 Mei 62 1 1 IM 01162 Fil ITI I Hardware Manufacturer Abbreviations: 1. (MK) Mckinney PER 2. (CIR) Corbin-Russwin C NOTE: (L-?- f Ac 0 lo WALL TYPE PER PLAN 3. (SC) Schlage 4. (NIT) Norton C -D(I-A� 5. Trimm 1. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON -!FWA- 9& ?-644)/t_y 0p6vMt.0 pt� rg<65,s (TR) ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP PER �iD(� tvi77V-&--r 7-14& "46- &--t Ug- J45,�,At 6. (PK) Pemko 7. (RW) Rockwood WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, SHIM AS REO'D 8 (PE) Peeko OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH 09 6ow "W-r k '4U.,U 161-, oqc 10/0, 1.9..;? 9' (DJ) Donlo HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. DEFLECTION 1b. (AL) Alarm Lock CHANNEL it. (BM) Sommer WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING 12. (KV) Knape & Vogt HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. The main door or doors are permitted to be equipped �vith PROJECT IDENTIFICATION: key -operated locking devices fro. the egress side provided the locking device is readily distinguishable as STOREFRONT FRAMING DOOR HARDWARE GROUPS: A NEW BRANCH locked and a readily visible sign with I -inch high letters I Hardware Group 1 HDW-1 IO#A, IOTA, I 01I on a contrasting background is posted on the egress side or . - (1006�,'IOSA, IOSA'110A,'120B, 123A) BANK adjacent to the door stating: THIS DOOR TO MMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. 1. All hardware to be provided by Manufacturer. FOR IBC 1010.1.9.3 2. Hardware Group 2 - HDW-2 (124A) 1. 3ea.Hinges TA27144.5x4.6US26D (MK) Peoples Bank STOREFRONT HEADERMAMB SIM. 2. 1 :a' Lockset D53PD SPA 626 (SC) 3. a. Wall Stop 409630 (RW) TYPE LEGEND: C4 T= I'-U' 4. 3 ea. Silencers 608 (RW) AT 3. Hardware Group 3 - HDW-3 (113A. I 115A, 119A, 121A, 122A) 201 Main Street DoorTVpes Door Frames 1. 3 ea. Hinges TA27144.5x4.5 US26D (MK) Edmonds, WA. 98020 2 ' 1 ea. Cardreader Lockset (TBD) 3. 3 ea. Silencers 608 (RW) C1 AS. 10 7CII 0 He Group 4 - HDW4 (116A, 117A. 118A) 4. rdw�ra PERMIT RESUBMITTAL D4 PER SCHEDULE ... R W DOOR WIDTH MD PER SCHEDULE 1. 3 ea. Hinges TA27144.5x4.5 US26D (MK) 10/29/2018 B B ATI 0 ER HEII ER SCHEDULE PER SCHEDULEt,, L 2. 1 a C3rdreaderLocksat (TBD) This drmNing Is: ;�EQ.j�EQ. 1 KIOSOI(rx2'LTDW630 (RW) WI DTH WIDTH 3. ea. Kick Plates PER SCHEDULE PER SCHEDULE PER SCHEDULE PER SCHEDULE a 4 1 a . Mop Plate K1050 10` x 1"LTDW 630 (RW) 5' 3 a.- Silencers 608 (RW) HDW.6(105C,11&IA) 1. Copyright 2017 Dykernan, Inc. 2. The Architects Instrument of Professional Service. 3. For use on this project only, Obtain Architect's 1. HardwareGroupli written permission for any other use or reproduction. 1. 1 ea. Pocket Door Frame PF28M (PK) N 2. 1 ea, Pocket Door Pull 1069 M (TR) PROJ ECT NUMBER: B.G. CI W t, L) i i 4 6. Hardware Group 6-HDW-6 (IIiA) 2016-030 W N 1. 3 ea. Hinges TA2714 4.6 x 4.5 US26D (MK) 0: W I I SIM. 1- 2. 1 ea. Latchset DIOSSPA626 (SC) 5A S. C, 3. 1 :a Wall Stop 409630 (RW) 3. 3 a'Silencers 608 (RW) W W SG A7 SG SG MARK DATE DESCRIPTION PER 1 10/2912018 Permit Response F FG FG-2 WD-00 WD-10 AL-10 AL-12 WID-B WID-SL RELITE TYPES (� TYP rB 1_� TYP TYP TYP PROJECT TEAM: A # T- 11" 16' - 9" 16-9" PER SCHED LE---,, 3EQ.SPACES PER SCHEDULIE�, C (-PER HEDULE 3EQ.SPACES PRINCIPAL IN CHARGE] K.S. PROJECT MANAGER: I - PROJECT ARCHITECT., I K.S. DRAWING TITLE: A Door Schedule TYP A9.1 0 DRAWING NUMBER: A3'� SG SG I G L.G L7G REA RE-2 RE-3 RE-4 R 77- 0) U D OCT H 1 4 1 5 BUILDIN _-F.)fff D I I B Ila WALL TYPE PER PLAN SOUND ATTENUATING BATT INSULATION WHERE INDICATED ON WALL TYPES MTL. STUD HEADER 1/21' x SOLID WOOD TRIM. STAIN SOLID WOOD STOP MTL. STUD HEADER 1/2" WOOD VENEER PLYWOOD, STAIN 1/Z'x SOLIDWOOD TRIM. STAIN SOLID WOOD STOP DOOR PER SCHEDULE I WOOD RELiTE SYSTEM AT SWING DOOR - SECTION 1 I/T w T-o" CHEAD JAMB, Sim. WALL TYPE PER PLAN SOUND ATTENUATING BATT INSULATION WHERE INDICATED ON WALLTYPES MTL. STUD HEADER 1/21' x SOLID WOOD TRIM. STAIN SOLID WOOD STOP WALL TYPE PER PLAN 11Z, x SOLID WOOD TRIM. STAIN SOLID WOOD STOP SOLID WOOD STOP 2".,-1/* EACH SIDE GLAZING THICKENS 3 5/9'MTL. STUDS NESTED D ATTENUATIN BATT INSULATION 117'WOOD VENEER BOLIN G WHERE INDICATED ON PLYWOOD, STAIN WALL TYPES WOOD RELITE SYSTEM - JAMB - MULLION 1 1/2" = V-0" 314"WOOD VENEER PLYWOOD. STAIN .29) SHORT WALL SECTION 31) RESILIENT BASE 1 1/2"= IW' T = V-0" WALL TYPE AND FINISH PER PLAN AND INTERIOR ELEVATIONS RESILIENT BASE SILICONE SEALANT FLOORING PER FLOOR FINISH PLAN < 4 EXISTING STOREFRONT 112-WOODIENr R =E DOOR PER SCHEDULE PLYWOOD, STAIN TRANSITION STRIP BACKER ROD EXISTING STOREFRONT AND SEALANT EXISTING BINTERMEDIATE MULLIONS CONCRETE SLAB PET PER EACH SIDE CONCRETE COLUMN SOLID WOOD STOP FLOOR FINISH PLAN BACKER ROD AND SEALANT EACH SIDE 1/,V'SAFETY GLASS BLOCKING Q BLOCKING USG PAPER -FACED 8 1 1/2" x 3 1/2" SOLID GW13 - PAINT GWB - PAINT METAL REVEAL TRIM WOOD TRIM, STAIN SOUND 5/V'GWB — RESILIENT BASE, 4 SOUND ATTENUATING BATT INSULATION ATTENUATING BATT SOUND ATTENUATION REFERTOC3/A9.10 MTL. STUDS SILL 4 4 WALL TYPE PER PLAN INSULATION INSULATION 3 518 METAL STUD WA U. TYPE AT IWO.C. N A SILL FLOO R FINISH PER PLAN 4 P ER PLAN —_q PARTITION AT EXTERIOR STOREFRONT PARTITION ON SITE OF STOREFRONT WOOD RELITE SYSTEM - SECTION CONCRETE TO CARPET THRESHOLD MULLION -4'� (�3) - ��LL 10 �N �q�- EXIST. COLUMN AT PARTITION WALL (�5) — (�2) 6"= V-9, — 1 I1Z' = V-0" 1 1 '��ON 1 I/Z' = V-9, 1 I/Z' = T-0" CARPET PER FLOOR FINISH PLAN #4 NOSING BARS, TYP. PROVIDE METAL STAIR NOSING BY AMERICAN SAFETY VMNAUHMMON INN TREAD COMPANY, STYLE #950 PORCELAN TILE PER FLOOR FINISH PLAN 1 4 4 I I I it 4 CARPET 4 44 TRANSITION - SCHLUTER SCHIENE-E. CLEAR ALUMINUM FLOOR TILE PER PLAN THIN SET MORTAR SHEETVINYLPER FINISH SCHEDULE METAL TRANSITION STRIP CARPET PER FINISH SCHEDULE CONCRETE SLAB 4 TRANSITION ' --\ SCHLUTER SCHIENE-E CLEAR ALUWNLI� FLOOR TILE PER PLAN WALK THIN SET MORTAR OFF MAT 4 4 < 4 4 4 4 4� 4 CONSULTANT: ALL WORK SUBJECT TO HEID INSPEC-PON FUR coo.E C0Ei'F1'vUN100E PROJECT IDENTIFICATION., A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: 1 Copyright 2017 Dykeman, Inc. 2� The Architect7s Instrument of Professional Service. 3. For use on this Project only. Obtain Architecrs written permission for any other use or reproduction. 2016-030 MARK DATE DESCRIPTION PRINCIPAL IN CHARGE:l K.S. PROIECT=RT - C :I KS. PROJECT JOB CAPTAIN: I A.O. Interior Details IDRAWING NUMBER: I [al ��PET �TO T�ILETRA�NSITIO�N j��T SHEETVINY�LTRA�NSITION NDETAAIL TILE TO WALK OFF MAT AT DOOR �'��PE �- A STEP AT ENTRY SECTION DETAIL -3� (A4 Al (A (A Fa- - -v-w 2 3 4 4 C 1111, D4� GWB Ceiling I r, -=,., 64� METAL CEILING JOISTS I 19Z�Zi,Zp RACK BLOCKING AT CEILING DGES AND AT W - 0" D.C. AS 1EQUIRED FOR SPAN EILING JOISTS SPACING J,1D SIZE AS EQUIRED FOR SPAN B/V'GW]3 PER PLAN I.. 11w SPACER BAR, NOTE 2 B qNOTE 3 1 CEILING TILE AT Opp. ADJACENT 1/8!'POP RIVETS AT WALLS PROVIDE 1/2" ADJACENT WALLS SPACE. NO POP RIVETS WALLANGLE PERIMETER NOTES: I . THE UNATTACHED PERIMETER SHALL HAVE A MIN. 1/2" CLEARANCE AT ENDS OF COMPONENTS. 2. LOCK CONTINUOUS SPACER BAR TO COMPONENTS ON THE UNATTACHED WALL. 3. SUPPORT PERIMETER TERMINAL COMPONENT ENDS BY A 12 GA WIRE ON ALL WALLS. - UNDERSIDE OF FLOOR OR NO, 12 GUAGE VERTICAL WIRE ROOF STRUCTURE ABOVE HANGER AT 41� - 0" D.C. TURN CEILING GRID LEVEL PRIOR DRILL 6/37HOLE AND INSTALL TO SETTING TUBE 'LL 1/8!'BOLT AND LOCKING NUT To VERTICAL COMPRESSION To SEC- STRUTAT12'-O"Q.C. OTHER LAP TUBES 4!'MINIMUM "EMT'SLEEVE FULLY EXTENDED POSrrION. SLAYED BRACING WIRES AT I k.-� 12'- 0" D.C. EACHWAY INDEPENDENT CADY MAIN RUNNER SUPPORT CLIP AT EACH LIGHT FIXTURE CROSS TEE CONNECTION SLOT END OF TUBE TO FIT A OVER CEILING RUNNER VERTICAL COMPRESSION STRUTS 1 . UP TO 8- - 0" USE (1) 3 56'25 GUAGE METAL STUD AT IZ- D.C. 2. 8' 01' TO 101 - 01- USE (2) 15/8725 GUAGE METAL STUDS AT 1Z - 0" D.C. FASTENED BACK TO BACK AT EACH SIDE OF MAIN RUNNER, TYPICAL. 3. 10'- WTO 16 - D" USE (2) 10 25 GUAGE METAL STUDS AT 12- - (Y' D.C. FASTEN SAME AS NOTE #2 ABOVE, 4. ALTERNATE: UP TO 6 - 0" USE 39'DIAMETER EMT CONDUIT. TYPICAL SUSPENDED CEILING 1 112- = V-0- - A A WALL TYPE PER PLAN 0.1 W'DIA. X 314"EMBED HILTI X- C 22 P8TH POWER ACTUATED ANCHOR AT 12" O.C, BOTTOM TRACK, 43 MILS. THICK, 1.26- MIN. FLANGE #10 SCREWS EACH SIDE AT STUD LOCATION EXISTING PT CONCRETE SLAB U 4 o T=,.?cal,N, n-Bearing Partition Sill D2X' - 1'-V' SPAN TABLE FOR METAL CEILING JOISTS SIZE THICKNESS 6 PSF LATERAL SUPPORT OF COMPRESSION FLANGE: MID SPAN 250 30 MILS AT 1V'O.C. 101-111, 250 30 MILS AT 21VO.C. 91-T. 350 30 MILS AT 19'O.C. 12'- 9" 350 30MILSAT24�-O.C., 11'.2" 362 30 MILS AT %' D.C. 11v - B!, 362 30 MILS AT 24!'O.C. IT -2- 400 30 MILS AT 16'O.C. 1v - V 400 30 MILS AT 24�'O.C. iv-51, 600 30 MILS AT IFO.C. 1T-3- 600 30 MILS AT 24" D.C. 16-61, NOTE: 1. PROVIDE METAL STUD THICKNESS (MILS) TO ACCOMODATE CEILING SPAN AND MAX. DEFLECTION OF L/240 IN ACCORDANCE WITH SSMA LOAD TABLES. 2. SEE LATERAL BRACING DETAIL WHERE GWB INSTALLED ONE SIDE ONLY. 37359 AL MAL 10-2&.10 STRUCTURAL DESIGN FOR LIGHT -GAUGE SCREWS, SLAB CONNECTIONS, AND DIAGONAL BRACES IN DETAILS A2, A3, A4, B2, B3, B4, AND D2 v DEFLECTION — TRACK TYPICAL BRIDGING WHERE REQUIRED. L�A L- D2 A9.2 BOTTOM TRACK ok Typical Non -Bearing Partition C3) 1"=V-0" 3 5/8" METAL STUDS AT 16'O.C. (TYP.) CONTINUE STUDS TO CEILING '362SI25-43 DIAGONAL BRACE AT 48" D.C. MAX RCP 518" GWB FFoR TYPI.-L NOTES REGARD G ATTACHMENT TO STRUCTURE ABOVE REFER TO DETAIL PER RCP B41A9.20 (TYPICAL SOFFIT DETAIL 0�2) 1 1'- 1.-011 NOTE: ADJUST CONCRETE ANCHOR LOCATION AS REQUIRED TO AVOID POST -TENSIONING STRANDS IN EXISTING SLAB. DO NOT PENETRATE EXISTING SLAB WITHOUT FIRST LOCATING POST -TENSIONING STRANDS. TYP. NON -BEARING P A22 Fj�-=—v—, A OST-TENSIONED CONCRETE SLAB DEFLECTION TRACK, DO NOT ATTACH WALL TRACK OR WALL FINISHES TO DEFLECTION TRACK 0.138 IN DIA. x 3/4" EMBED HILTI X-C22 P8TH POWDER ACTUATED FASTNERS @12" OC, SEE -NOTE WALL PER PLAN SPAN TABLE FOR METAL STUD PARTITIONS 8 SIZE LZ THICKNESS SPAN ASSUMES GWB BOTH SIDES FULL HEIGHT 2 10 30 MILS AT 2W'O.C. WALLS UP TO W - G'IN UNSUPPORTED LENGTH 350 30 MILS AT 24�'O.C. WALLS UP TO 13. O"IN UNSUPPORTED LENGTH S' 3 6/8" 30 MILS AT 19'O.C. WALLS UP TO 16'. WIN UNSUPPORTED LENGTH 3 5/8" . 30 MILS AT 12"O.C. WALLS UP TO 1W - WIN UNSUPPORTED LENGTH 4'. 30 MILS AT ZVO.C.1 WALLS UP TO 1,V - WIN UNSUPPORTED LENGTH ,V' 30 MILS AT 16- D.C. WALLS UP TO 1(V - W IN UNSUPPORTED LENGTH 30 MILS AT 24. 0 C. WALLS UP TO 20 - Z' IN UNSUPPORTED LENGTH LLS UP TO 23- WIN UNSUPPORTED LENGTH NOTE: 1. PROVIDE METAL STUD THICKNESS (MILS) TOACCOMODATE PARTITION HEIGHT AND MAK DEFLECTION OF L/240 IN ACCORDANCE WITH SSMA LOAD TABLES. ICBO ER4943P 2. SEE LATERAL BRACING DETAIL WHERE GWB IS NOT INSTALLED. RCLP _ — F 3 5/8"METAL F G W . I. I 5W TYPE "X"G. PA NT 518!'TYPE PAINT 35/8"METALFRAMIN G ACOUSTICAL PANEL FF R -P A NOTES RE.ARDINCGL STRUCTURE ABOVE ATTACHMENT T REFER TO DETAIL B41A9.20 362SI2543 DIAGONAL BRACE AT 48" D.C. MAX. �31� ACT SOFFIT AT GWB CEILING 3) r = T-9, CEILING HE GHT PER RCP TS2S12r,43 )LAGONAL 3RACEAT48" )C. MAX, 3 6/8 METAL STUD AT 16" D.C. 'GWB [�MPIE�LNOTE. ATTACHMENT TO STRUCTURE ABOVE REFER TO DETAIL B4/A9.20 CEILING HEIGHT PER RQF CEILING AT SUSPENDED PARTITION A3 T i —,,2.= v.o. - GENERAL N TE: 1 . DO NOT INSTALL DRILL -IN ADHESIVE AND EXPANSION ANCHORS IN THE POST -TENSIONED SLAB. 2. DRILLING INTO POST -TENSIONED SLAB WITHOUT APPROVAL FROM STRUCTURAL ENGINEER OF RECORD IS NOT PERMITTED. 3. ALL BUILDING SYSTEMS: MECHABNICAL, ELECTRICAL, PLUMBING FIRE PROTECTION SHALL PLACE DUCTS, CHASES, PIPES OR PIPE SUPPORTS, CONDUIT SLEEVES AND HANGER INSERTS, ECT. INTO THE POST -TENSIONED SLAB PRIOR TO POURING THE CONCRETE. 4. GC TO SCAN SLAB TO VERIFY LOCATION OF ALL EXISTING STRUCTURE REINFORCEMENT AND P-T TENDONS. CONTRACTOR IS TO MAINTAIN T'CLEAR FROM P-T TENDONS IN ALL DIRECTIONS AND IS NOT TO CUT EXISTING REINFORCEMENT. 3116" DA. x 1 1/2" EMBED TAPCON SCREW AT BRACE LOCATION, SEE NOTE — EXISTING POST -TENSIONED CONCRETE SLAB, SEE NOTE #1 — 3116?'DIA. x 1 1/2" EMBED rf (2) #12 SCREWS — TAPCON SCREW AT 18" 54 MIL. x 2 x 2 x 01- WANGLE D.C. - SEE *NOTE AT BRACE LOCATION — EWS ES AT #12 SCRJ STUD LOCATION 3 5/8'. MTL. S TUDS 362S125-43 DIAGONAL BRACE AT 49' D.C. MAX. PER RCP ACOUSTICAL CEI 3 5/6, Mi )(- (2) #12 SCREWS 1/Z'THICK, W-3 CEILING PANELS HANG ON 1/4!' FRENCH CLEATS WITH 11,V'SHIM SPACE NOTE: ADJUST CONCRETE ANCHOR LOCATION AS REQUIRED TO AVOID POST -TENSIONING STRANDS IN EXISTING SLAB. DO NOT PENETRATE EXISTING SLAB WITHOUT FIRST LOCATING POST -TENSIONING STRANDS. *-'�,§OFFIT AT TELLER POD A, aM�T— --- ACOUSTICAL SIB!'TYPE"X"G.W.B. PAINT 3 5/8!'METAL FRAMINGI ACOUSTICALTILE CEILING A-� TRANSITION AT '4 ).1112" = 1 W- It - ALL VIVORIK GUgj�,--f�T TO FIELD 191%q8P7CTIoI1 FOR GODE REGISTRATION STAMPS: REGISTERED ARCHITECT C KELLI GARDINER SMITH PROJECT IDENTIFICATION: A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 B This drawing is: 1. Copyright 2017 Dykernan, Inc. 2. The Architect's Instrument of Professional Service. 3. For use on this project only, Obtain Architect's �,U.n pemission for any other use or reproduction. PROJECT NUMBER: 2016-030 MARK DATE DESCRIPTION PER 1 1012IN2018 PernnitResponse, PRINCIPAL IN CHARGE:l K.S. PROJECTMANAGER: I PROJECT ARCHITECT. I K.S. JOB CAPTAIN: I A.G. 362SI25-43 DIAGONAL i DRAWING TITLE: BRACE AT 4V' D.C. MAX. A OTES FOR TYP:C LN Interior Details REGARD N ATTAC4 MENT PERRCpJ, STRUCTURE ATOOVE REFER TO DETAIL B41A9.20 CEILING 2 3 4 10 362S125-43 DIAGONAL BRACE AT 48" O.C. MAX. . x" —5/8" TYPE 'X'GWI3 5/8"METALFRAMING- t 518!'METAL FRAMING So = F!CP_ I �- — — — — — — — — — — — PER ROF 6!'METAL STUD FRAMING 1/2" THICK, W-3 CEILING PANELS HANG ON 1X' FRENCH CLEATS WITH IWSHIM SPACE T- FOR TYP _L NOTES :NG —WAULTYPE REGARD PER PLAN IT To ATTACHMEN 1 STRUCTURE ABOVE 5/9'TYPE'X'GWB REFER TO DETAIL L BQA9.20 PAINT PER INTERIOR 1,v ELEVATIONS SOFFIT AT TELLER BACK WALL B 1 .. = J.-ty. Ill _;��P WALL TYPE PER PLAN SOUND ATTENUATING BATT INSULATION WHERE INDICATED ON WALL TYPES 6" MTL. STUD HEADER Nh ."AN T-1 37358 T STRUCTURAL IGN FOR ID LIGHT -GAUGE SC EWS, SLAB L�__ I CONNECTIONS, AND DIAGONAL R RCP . ............... BRACES IN DETAILS Al, A2, AND 131 ACOUSTICAL TILE-1 CEILING 362S12543DIAGONAL BRACE AT 49'O.C. MAX. 5/8"TYPE 'X'GWB 5/8" METAL FRAMING 4_ 2�1_ NOTES S., METAL STUD F CA � YPIN E0 R Tn, FRAMING REGARD G 1/2" THICK, W-3 CEILING ATTACHMENT To TRMCTUREABOVE PANELS HANG ON 1IN' REFER TO DETAIL FR NCH CLEATS WITH A. 17SHIM SPACE SOFFIT AT TELLER AREA (A BARN DOOR HEAD/SILL Al 1 1/2"= V-0" ewA , oe�w� otwA ois-� wok __,o -%..- 2 362S125-43 DIAGONAL BRACE AT 48P D.C. MAX. FOR TYPICAL NOTES REGARDING ATTACHMENT TO URE U r z VE STRUCT R ABOVE REFER TO DETAIL Iv- 13411AS.270 11/2" x SOLID WOOD TRIM. STAIN SOLID WOOD STOP GLAZING THICKENS SOLID WOOD STOP 1/4!'PLYWOOD MTL. STUD HEADER 518"x WOOD VENEER PLYWOOD, STAIN rA3 Z� PER PER RCP, 5/8 " x WOOD VENEER r__� TYP PLYWOOD BOTH SIDES, STAIN 17 10PLYWOOD BARN DOOR FRAME 114" — — — — — — — — — — — — — — 3 6V MTL. STUDS - NESTED SOLD WOOD STOP BARN DOOR JAMB 4 WALL TYPE PER PLAN DOOR STOP BARN DOOR R E 0 U D, OCT z 9 28% ALL WORK GUBJEM" TO IFFID IN' REGISTRATION STAMPS: C A NEW BRANCH BANK FOR Peoples Bank AT 201 Main Street Edmonds, WA. 98020 PERMIT RESUBMITTAL 10/29/2018 This drawing is: I Copyright 2017 Dykernan, Inc. i The Architects Instrument of Professional Sew ce. 3. For use on this Project only. Obtain Architecrs written pemission for any other use or reproduction. PROJECT NUMBER: 2016-030 MARK DATE DESCRIPTION PER 1 IM29/2015 armt esoonse PROJECT TEAM PRINCIPAL IN CHARGE:l K S. PROJECT MANAGER,, I - PROJECT ARCHITECT: I K.S. JOB CAPTAIN: A.0. A Interior Details D I C I 11Fj PER -- — - --- — - — �: — - — - — - — - — - — - — - TENANT SIGNAGE ADD STREET PEDESTRIAN ROUTE ACCESSIBLE ROUTE TO RETAIL SPACE #2 Li r T __.r I - f I r RETA IL SPACE #2 -5,298 Sf, Uwj U) L z D1 0 ACCESSIBLE ROUTE TO ELEVATOR / PARKING TENANT SIGNAGE 1 RETAIL SPACE #1 L 3,794 SF L 0 2 3 2-ND AVENUE NORTH ------------------------------------- ENTRANCE I EXIT REGISTRATION STAMPS 9,39 RE ISTERED ARCHITECT KELLI CARDINER SMITH PROJECT IDENTIFICATION: 1041- a- as r A CCESSIBLE ROUTE TO IL TRASHROOM lot; —,A :8 LI Cr AN IAISI'KBJ 2 N D U) SPACE ACCESSIBLE 0 77777- PARKING SPACE FOR EXISTING PARKING GARAG offl ""Hill: 12 R L#1 ETA] 6 L 9 5 16 17 8 1 9 20 1 [2 23 1,4 25 ril 7 �6 T At PROPERT LINE OPEN ALLEY SHADED AREA INDICATES TENANT SPACE LINE INDICATES ACCESSIBLE ROUTE OF TRAVEL L!_� PER 0 10, 20' 40' scale: !'= 20'-0" NORTH This drayOng Is: . op 9 y eman, ne. 2 The Architeds Instrument of Professional Semice. 3. For use on this Project only. Obtain Architect's written permission for any other use or reproduction. PROJECT NUMBER: 2016-030 MARK DATE DESCRIPTION PER 1 10/2912018 Permit Response PROJECT TEAM: PRINCIPAL IN CHARGE:l K.S. PROJECTMANAGER: I - PROJECT ARCHITECT: I K.S. JOB CAPTAIN: I A.D. DRAWING TITLE: A Site Plan (A,j� Site Plan 1 2 RESUB 3 4 OCT Z9 2018 C1­T_YtiF_fDlAON&S