BLD20180822 (2)OV ED IV
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
N�A- �kr,,
�4
STATUS: ISSUE""w2u%—� Pe - nni . t# BLD2018082-2
BUILDING PERMIT
Expiration Date: 01/02/2019 Project Address: 71 WEST MAIN ST., EDMONDS
Parcel No: 00454800201901
I'L411PIA"I I OWNER APPLICANT CONTRACTOR
FERRY TERMINAL HERMANSON COMPANY HERMANSON COMPANY
C/O ON THE DOCK / BREAK ROOM C/O KIMBERLY LANGE C/O KIMBERLY LANGE
PO BOX 3303 10 1221 2ND AVE N 1221 2ND AVE N
SEATTLE, WA 98133 KENT, WA 98032 KENT, WA 98032
(206) 575-9700 (206) 575-9700
LICENSE #- HERMACLO05BJ EXP 08/25/2018
JOB DESCRIPTION
INSTALL SPLIT SYSTEM HEAT PUMP. INSTALL OUTDOOR UNIT ON EXTERIOR OF BUILDING
VALUATION: $0
PERMIT TYPE- Commercial
PERMIT GROUP: 40 - Mechanical
GRADING N CYDS: 0
TYPE OF CONSTRUCTION
RETAINING WALL ROCKERY:
OCCUPANT GROUP:
OCCUPANT OAD
FE CE: 0 X 0 FT.)
CODE: 2015
IOTHER: ------- OTHER DESC:
IZONE:
INUMBER OF STORIES: 0
VESTED DATE:
NUMBER OF DWELLING UNITS: 0
LOT #:
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
ASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
3 RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
BEDROOMS: 0 BATHROOMS: 0
BEDROOMS: 0 BATHROOMS: 0
FRONTSIA-BACK SIDESEIFBACK REARS ff-BACK
REQUIRED: PROPOSED: =1 KEU� PROPOSED IREQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:0 IREQUIRED: PROPOSED
SETBACK NOTES
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION
INSURANCE AND RCW 18:27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
�A44— g—zv-- -, L a, i � c 11211Y
SignaTure 0 Print Name -1 Date Released By Date
ATTENTION
ITIS UNLAWFUL To USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBC1 10/ IRCI 10.
FlRE APPLICANT ASSESSOR
STATUS: ISSUED
BLD20180822
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon subrnittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• SoundiNoise originating from ternporary construction s ites as a result of construction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harrrdess the City of Edmonds, Washington, its officials, employees, and agents from an), and all claims for damages of
whatever nature, aris ing directly or indirectly from the issuance for this permit. Issuance of this pernit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT
TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING
ENGINEERING (426) 771-0220 EXT. 1326
1. Go to: www.edmondswa.gov
Building Department Inspections
2. Then: SeNces
are now scheduled online. If you
FIRE (425) 775-7720
3. Then: Perm its/Development
haw difficulties, please call the
4. Then: Online Permit Info
Building Department front desk for
PUBLIC WORKS (425) 771-0235
5: If you don't have one already, create a
assistance during office hours.
login (upper right hand comer)
(425) 771-0220
RECYCLING (425) 275-4801
6: Schedule your inspection
I I
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Preferred. and whether you prefer morning or afternoon.
• B-Preconstruction meeting
• B-Mechanical Rough In
• B- Refer line Pressure test
• B-Mechanical Final
, 12 C. I S91
BUILDING PERMIT
APPLICATION
Development Services
Building Division
121 5th Ave N / Edmonds, WA 98020
425.771.0220
For handouts, submittal requirements, permit status and inspection
scheduling information go to: httij://www.edmondswa.gov/
JOB SITE INFORMATION/LOCATION: (Where the work Is taking place)
JobSiteAddress: 199 Sunset Ave S Edmonds, WA 98020
Parcel: -I-\ vj'� ffia%'n
Lot /Unit/Suite #: Subdivision:
2.q4j 2 4.4 fIGATITi 0 14 1;
Name: Washington State Ferries
MailingAddress: 2901 3rd Ave Suite 500
City/State/Zip: Seattle, WA 98121
Phone#: 206-389-8513
Email: colest@wsdot.wa.qov
OWNER INSTALLATION: *If yes, read and sign*
Will work be performed by the property owner? 0 Yes IB No
I own, reside in, or will reside in the completed structure.
This installation is being made on property that I own which is
not intended for sale, lease, rent, or exchange according to
RCW 18.27.090.
Owner Signature:
APPLICANT/ CONTACT INFORMATION:
Name of Applicant: Kimberly Lange
Mailing Address: 1221 2nd Ave N
City/State/Zip: Kent, WA 98032
Phone#: 206-573-2023
E-mail: klange@hermanson.com
GENERAL CONTRACTOR: (if different from applicant)
General Contractor: Hermanson Company
Mailing Address: 1221 2nd Ave N
City/State/Zip: Kent, WA 98032
Phone#: 206-575-9700
E-mail: klanqe@hermanson.com
WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE:
HERMACLO05BJ
CITY OF EDMONDS BUSINESS LICENSE#: NR-025058
Office Use Only
TYPE OF PERMIT (Provide
El Accessory Structure/
Detached Garage
Details on Page 2)
0 Addition
• Demolition
13 Mechanical
• New Single Family/ Duplex
D Plumbing
• Fire Sprinkler
El Remodel
• New Commercial/ Mixed Use
0 Re -Roof
• Signs
0 Tank
0 Tenant Improvement
0 Other
Remodel Permit fees are based on:
The value of the work performed. Indicate the value (rounded to
the nearest dollar) of all equipment, materials, labor, overhead,
and the profit for the work indicated on this application.
Valuation:
PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION
Basement sq ft: Finished 0 Unfinished 0
1st Floor, sq ft:
2nd Floor, sq ft.
Garage/Carport:, sq ft:
Deck/Covered Porch/Patio:
Other sq ft:
PROJECT DESCRIPTION
Install Split System Heat Pump.
Install outdoor unit on exterior of Building
I certify that the information I have provided on this form/application is true,
correct and complete, and that I am the property owner or duly authorized
agent of the property owner to submit a permit application to the City of
Edmonds.
A 0
PrintName: Yim L&MV-N-
Signature: YIAAA Date
yv- LZ
U/nutma"bun
Building Today Dofining Tomorrow RECERVED
nermanson Company LLr tel .206-575-9700
1221 2nd Avenue North fax 206-575-9800
Kent, WA 98032 JUN 14 2018
CRrjpy (C(gpy DEVELOPMENT SERVICES
COUNTER
Project: WSF EDMONDS — BREAK RM
199 SUNSET AVE. S.
EDMONDS, WA. 98020
Date: JUNE-12-2018
2018.06.13 14:52:43-07'00'
1 am approving this document
HVAC SYSTEM COOLING/HEATING CALCS
CARRIER HAP VERSION: 5.10
PRMIT SUBMITTAL PACKAGE
Mechanical Construction,
Engineering and Service
www.hermanson.com
Hermanson
Building Today, Defining Tomorrow Hermanson Company LLP tel 206-575-9700
1221 2nd Avenue North fax 206-575-9800
Kent, WA 98032
Project: WSF EDMONDS — BREAK RM
199 SUNSET AVE. S.
EDMONDS, WA. 98020
Date: JUNE-12-2018
7/7
Hermanson
Building Today, Defining Tomorrow
HVAC SYSTEM COOLING/HEATING CALCS
CARRIER HAP VERSION: 5.10
ENVELOPE INPUTS
Mechanical Construction,
Engineering and Service
www.hermanson.com
Window Constructions
Edmonds WSF Break Rm — v5 10 06/12/2018
Hermans�n Company LLP — 03:25PM
Existing Windows
Window Details:
DetailedInput ................................................. ....................... No
Height. ....... ....... .......................... .......................... ..... . 4.00 ft
Width................ ........... _ .. .................................................. - 1.00 ft
Overall U-Value -- . ................ .......... ..................... 0.450 BTU/(hr-ft2-*F)
Overall Shade Coefficient .................................... --. .. 0.8110
Hourly Analysis Program v5. 10 Page 1 of 1
Wall Constructions
Edmonds WSF SERVER Rm v5 10 06/12/2018
Hermans�n Company LLP — — 03:08PM
Existing walls
Wall Details
Outside Surface Color Medium
Absorptivity 0.675
Overall LI-Value 0.104 BTU/(hr-ft2. *F)
Wall Lavers Details (Inside to Outside)
Layers
Thickness
in
Density
lb/ft'
Specific Ht.
BTU/ lb-'F
R-Value
hr-ft'-*F BTU
Weight
I b/ft2
Inside surface resistance
0.000
0.0
0.00
0.68500
0.0
Gypsum board
0.625
50.0
0.26
0.56022
2.6
R-I 1 batt insulation
2. 00
0.5
0.20
8.01282
0A
Outside surface resistance
0.0001
0.01
0.001
0.333001
0.0
Totals
3.1251
.1
1 9.591041
2.7
Hourly Analysis Program v5.1 0 Page I of 1
Roof Constructions
Edmonds WSF Break Rm — v5 — 10 06/12/2018
Hermansw Company LLP 03:25PM
Existing root
Roof Details
Outside Surface Color Medium
Absorptivity .... ..... - - -------- 0.675
Overall U-Value - . . . ........... ........ 0.062 BTU/(hr-ftl-'F)
Roof Lavers Details (inside to Outside)
Layers
Thickness
in
Density
lb/ft'
Specific Ht.
R-Value
Weight
I b/ft2
Inside surface resistance
0.000
0.0
0.00
0.68500
0.0
1/2-in gypsum board
0.500
50.0
0.26
0.44803
2.1
R-13 batt insulation
4.000
0.5
0.20
12.82051
0.2
1/2-in plywood
0.500
34.0
0.29
0.621891
1.4
Asphalt sheathing
0.500
70.0
0.35
1.43678
2.9
Outside surface resistance
0.000
0.0
0.00
0.17000
0.0
Totals
5.500
16.18221
6.6
Hourly Analysis Program v5.10 Page 1 of I
Hermanson
Building Today, Defining Tomorrow Hermanson Company LLP tel 206-575-9700
1221 2nd Avenue North fax 206-575-9800
Kent, WA 98032
Project: WSF EDMONDS — BREAK RM
199 SUNSET AVE. S.
EDMONDS, WA. 98020
Date: JUNE-12-2018
Hermanson
Building Today, Defining Tomorrow
HVAC SYSTEM COOLINGMEATING CALCS
CARRIER HAP VERSION: 5.10
SPACEINPUTS
Mechanical Construction,
Engineering and Service
www.hermanson-corn
Space Input Data
Edmo6ds WSF Break Rm v5 10 06/12/201 E
Hermans&n Company LLP- - 03:20PIV
I- WSF Edmonds Break Rm
1. General Details:
FloorArea ... ........... ..........................................................
80.0
ft2
Avg. Ceiling Height ...............................................................
8.0
ft
Building Weight . ........ .
. ..................... ............................ 70.0
lb/ft2
1.1. OA Ventilation Requirements:
Space Usage . ..........................
GENERAL: Break room
OA Requirement 1 ...................
... ... .. ....... 5.0
CFM/person
OA Requirement 2 -----------
-- - ........................... 0.06
CFM/ft'
Space Usage Defaults..
ASHRAE Standard 62.1-2010
2.lnternals:
2.1. Overhead Lighting:
Fixture Type --------------------- ---- Recessed (Unvented)
Wattage .1 1 ---r- ........... 0.96 WAV
Ballast Multiplier ...................... ... -1-11-11- ....--1-08
Schedule - - -- - - ---------- 90.1 Retail Lights/Elec
2.2. Task Lighting:
Wattage . .......... ... 0.00 W/f12
Schedule., ..... - - ------------ None
2.3. Electrical Equipment.,
Wattage . ...... .. ............ ... ...... . . .. . .... 200.0 Watts
Schedule .................................... 90.1 Retail Lights/Elec
3. Walls, Windows, Doors:
2.4. People:
Occupancy... . . ............. ...... ......... . .. . ........ - 1.0 Person
Activity Level . ............................. ... - ----- Seated at Rest
Sensible ... ................. ---------------------------------------- 230.0 BTU/hr/person
Latent.- . .. ............ ------- - --- ---- -- -------------------- 120.0 BTU/hr/person
Schedule 90.1 Retail Occupants
2.5. Miscellaneous Loads:
Sensible -------------------- - - -
Schedule .. . . . ..............................
Latent. ....................................... -..
Schedule...........................................
Exp.
Wall Gross Area (ft')
Window I Qty.
Window 2 Qty.
Door 1 City.
N
80.0
4
0
S
80.0
7
0
—0
0
W
60.0
4
0
0
E
1 60.0
1 4
1 0
0
3.1. Construction Types for Exposure N
Wall Type ............ ....... ......... Existing walls
1 st Window Type ............... ................. Existing Windows
3.2. Construction Types for Exposure S
Wall Type . ---------------------- --- ..... . Existing walls
1 st Window Type ... . -- ---- -- - - ---- . Existing Windows
3.3. Construction Types for Exposure W
Wall Type 11 . . -- - .. . . . ... .. . ............... Existing walls
1 st Window Type .... ......................... - - - Existing Windows
3.4. Construction Types for Exposure E
Wall Type -- - -------------------- ----------- - -- - --- — Existing walls
1 st Window Type ...... . . ........................... .. .... Existing Windows
4. Roofs, Skylights:
Exp.
Roof Gross Area (ft2
of Slope (deg.)
Skylight Qt
H
80.0
0
0
4.1. Construction Types for Exposure H
Roof Type -1- ................ ---- ............... Existing roof
5. Infiltration:
Design Cooling ........ . ... ......................................... .. .... 0.00 CFM
Design Heating .................................. ... ............ -, 2.00 ACH
EnergyAnalysis .................................... ............. .............. � 0.00 CFM
Infiltration occurs at all hours.
----- ------ - - 0 BTU/hr
............ I.. None
................ -. 0 BTU/hr
............ I ... None
Hourly Analysis Program v5. 10 Page 1 of 2
Space Input Data
Edmonds WSF Break Rm v5 — 10 06/12/2018
Hermans&n Company LLP7 03:20PM
6. Floors:
Type - ,, . Floor Above Unconditioned Space
FloorArea- ........
80.0
ft2
Total Floor U-Value.
0.088
BTU/(hr-ftl.'F)
Unconditioned Space Max Temp. . ...
82.0
*F
Ambient at Space Max Temp . ..... . . . .......
82.0
'F
Unconditioned Space Min Temp.
24.0
'F
Ambient at Space Min Temp . ............
24.0
'F
7. Partitions:
(No partition data).
Hourly Analysis Program v5. 10 Page 2 of 2
Hermanson
Building Today, Defining Tomorrow Hermanson Company LLP tel 206-575-9700
1221 2nd Avenue North fax 206-575-9800
Kent, WA 98032
Project: WSF EDMONDS — BREAK RM
199 SUNSET AVE. S.
EDMONDS, WA. 98020
Date: JUNE-12-2018
i),
Hermanson
Building Today, Defining Tomorrow
HVAC SYSTEM COOLING/HEATING CALCS
CARRIER HAP VERSION: 5.10
SYSTEMINPUTS
Mechanical Construction,
Engineering and Service
www.hermanson.com
WSF EDMONDS BREAK RM Input Data
Project Name: Edmonds — WSF Break Rm — v5 — 10 06/12/2018
Prepared by: Hermanson Company LLP 03:21 PIV
1. General Details:
Air System Name . . . ... .......
. .. ........................ . WSF EDMONDS BREAK RM
Equipment Type ... .................................................
11 — Terminal Units
Air System Type ... ...................................................................
.. Packaged DX Fan Coil
Numberof zones ........... ... ..............................................................................
1
Ventilation ............................................
...... ........................................... Direct Ventilation
2. Dedicated Outdoor Air System Components:
(Dedicated Outdoor Air System not used: no inputs)
3. Zone Components:
Space Assignments:
lZone 1: Zone I
11 - WSF Edmonds Break Rm xi
Thermostats and Zone Data:
T-Stat
Cooling T-Stat
Cooling T-Stat
Heating T-Stat
Heating T-Stat
Throttling
Zone
Occ.
Unocc.
Occ.
Unocc.
Range
(*F)
('F)
(*F)
(*F)
(*F)
1
72.0
80.0
70.0
65.0
1.00
Thermostat Schedule 2417 HVAC Schedule
Unoccupied Cooling is ......... I - � ..Available
Common Terminal Unit Data:
Cooling Coil:
Design Supply Temp . ................................... .............
............ .......... 55.0 'F
Coil Bypass Factor .................................. ......................................
_. — 0.100
Cooling Source ..........................................................
... ..... ..... ............. .. Air -Cooled DX
Schedule...................................... .............. ........... ...
.. ......................... JFMAMJJASOND
Heating Coil:
DesignSupply Temp . ... .. .............................................. - .................. . . ..... 95.0 'F
Heating Source ........ ............................................. ... ... ... .............. Electric Resistance
Schedule., .................................... ... ....................................................... JFMAMJJASOND
Fan Control ... ........ ................. ... .. .. .............. Fan On
Ventilation Sizing Method Sum of Space OA Airflows
Terminal Units Data:
Air
Distribution
Air
Design
Air
Effectiveness
Distribution
Fan
Supply
Zone
Terminal Type
Distribution
Specification
Effectiveness
Minimum Airflow
Fan Performance
Efficiency
Temp.
I
Fan coil
Ceiling supply /
ceiling return
Not Used
-
0.00 CFM/person
0,00 in wg
50%
4. Sizing Data (Computer -Generated):
System Sizing Data:
Sizing Data:
Cooling Supply Temperature___ .... ... . ...... ... ............................... ......... _55.0 'F
Heating Supply Temperature . � - - ----------- .......................... .............. .................... � 95.0 'F
Hydronic Sizing Specifications:
Chilled Water Delta-T ......................
Hot Water Delta-T .. ..........................
Safety Factors:
Cooling Sensible ...................
Cooling Latent ...... . .. .. ..............
Heating. � . .............. .............
Zone Sizing Data:
Zone Airflow Sizing Method ----- --
.............. . .......................................... 10.0 'F
..... ............. ............................... . ... ...... 20.0 'F
..................................... ...... .. ........................ 0 %
................. . ................................. .... ... 0 %
...... .... .............................................. ... . ..... 0 %
. Sum of space airflow rates
Hourly Analysis Program 5.10 Page I of 2
I WSF EDMONDS BREAK RM Input Data
Project Name: Edmonds—WSF Break Rm_v5_1 0 06/12/2018
Prepared by: Hermanson Company LLP 03:21 PM
Space Airflow Sizing Method Individual peak space loads
Zone
Supply Airflow
(CFM)
Zone Htg Unit
(MBH)
Reheat Coil
(MBH)
Ventilation
(CFM)
1
331.3
9.8
5. Equipment Data
Terminal Cooling Units - Air -Cooled DX
Estimated
Gross
Capacity
Compressor
Maximum
Design
Cooling
Oversizing
+ OD Fan
ARI
Conventional
Load
OAT
Equipment
Capacity
Factor
Power
Performance
Cutoff OAT
Zone
oF
Sizing
(MBH)
(kW)
Rating
Units
('F)
I
n/a
95.0
Auto -Sized 1
0
11.000
EER
0.0
Hourly Analysis Program 5.10 Page 2 of 2
Hermanson
Building Today, Defining Tomorrow Hermanson Company LLP tel 206-575-9700
1221 2nd Avenue North fax 206-575-9800
Kent, WA 98032
Project: WSF EDMONDS — BREAK RM
199 SUNSET AVE. S.
EDMONDS, WA. 98020
Date: JUNE-12-2018
Hermanson
Building Today, Defining Tomorrow
HVAC SYSTEM COOLING/HEATING CALCS
CARRIER HAP VERSION: 5.10
SYSTEM OUTPUTS
Mechanical Construction,
Engineering and Service
www.hermanson.com
Dedicated Outdoor Air System (DOAS) Sizing Summary for WSF EDMONDS BREAK RM
Project Name: Edmonds - WSF Break Rm v5 10 06/12/2018
Prepared by: Hermanso� Company LLP 03:24PM
Air System Information
Air System Name - .-.-...WSF EDMONDS BREAK RM
Equipment Class ..................................... -- ......... TERM
Air System Type ... ................................................ . PKG-FC
Sizing Calculation Information
Calculation Months .... ......................................... Jan to Dec
Sizing Data ...... ....... ... ... ...................................... Calculated
Number of zones ........................................ I
Floor Area.... ............................ .................... ......... 80.0 ft2
Location . ........................................ EDMONDS, Washington
Zone CFM Sizing . ................... Sum of space airflow rates
Space CFM Sizing ............. .. Individual peak space loads
NOTE: No other data is applicable for a Terminal Units air system without a Dedicated Outdoor Air System (DOAS).
Hourly Analysis Program 5. 10 Page I of 6
Zone Sizing Summary for WSF EDMONDS BREAK RM
Project Name: Edmonds WSF Break Rm v5 10 06/12/2018
Prepared by: Hermanso�-Company LLP - - 03:24PM
Air System Information
Air System Name WSF EDMONDS BREAK RM
Equipment Class ........ ... .. . TERM
Air System Type -- ... ........ PKG-FC
Sizing Calculation Information
Calculation Months ........ .11 1."..., - 1. Jan to Dec
Sizing Data , - � . ............... - ...... Calculated
Terminal Unit Sizing Data - Cooling
Number of zones
Floor Area .. .......... ............. ... ............ 80.0 ft2
Location 11 1 - � .. EDMONDS, Washington
Zone CFM Sizing., ............ Sum of space airflow rates
Space CFM Sizing ..... -, . Individual peak space loads
Total
Sens
Coil
Coil
Water
Time
Coil
Coil
Entering
Leaving
Flow
of
Load
Load
DB/WB
DB/WB
@ 10.0 -F
Peak Coil
Zone
Zone Name
(MBH)
(MBH)
(*F)
(*F)
(gpm)
Load
CFM/ft2
Zone 1
6.3
6.2
73.1/61.5
55.9/54.8
Aug 1500
4.14
Terminal Unit Sizing Data - Heating, Fan, Ventilation
Heating
Htg Coil
Heating
Coil
Water
Fan
OA Vent
Coil
EnVLvg
Flow
Design
Fan
Fan
Design
Load
DB
@20.0 'F
Airflow
Motor
Motor
Airflow
Zone Name
(MBH)
('F)
(gpm)
(CFM)
(BHP)
(kW)
(CFM)
Zone 1
4.6
68.1/80-9
331
0.0001
0.0001
10
Zone Peak Sensible Loads
Zone
Zone
Zone
Cooling
Time of
Heating
Floor
Sensible
Peak Sensible
Load
Area
Zone Name
(MBH)
Cooling Load
(MBH)
(ft2)
Zone 1
6.1
Sep 1500
4.�
80.0
Space Loads and Airflows
Time of
Cooling
Peak
Air
Heating
Floor
Zone Name
Sensible
Sensible
Flow
Load
Area
Space
— Space Name
Mult.
(MBH)
Load
(CFM)
(MBH)
(ft2)
CFM/ft2
Zone 1
1- WSF Edmonds Break Rm
6.1.
Sep 1500,
331
4.2
80-0
4.14
Hourly Analysis Program 5.10 Page 2 of 6
Ventilation Sizing Summary for WSF EDMONDS BREAK RM
Project Name: Edmonds WSF Break Rm v5 10 06/12/2018
Prepared by: Hermanso�-Company LLP — — 03:24PM
1. Summary
Ventilation Sizing Method - -------------------- -- - - ...-Sum of Space OA Airflows
2. Space Ventilation Analysis
2.1 Zone: Zone 1
Zone Name / Space Name
Mult.
Floor
Area
(W)
Maximum
Occupants
Maximum
Supply Air
(CFM)
Required
Outdoor Air
(CFM/person)
Required
Outdoor Air
(CFM/ft-)
Required
Outdoor Air
(CFM)
Required
Outdoor Air
(% of supply)
Uncorrected
Outdoor Air
(CFM)
Zone 1
1- WSF Edmonds Break Rm
1
80.0
1.0
331.3
5.00
0.06
0.0
0.0
9.8
Totals (Incl. Space Multipliers)
331.3
9.8
Hourly Analysis Program 5.10 Page 3 of 6
Air System Design Load Summary for WSF EDMONDS BREAK RM
Projed Name: Edmonds WSF Break Rm v5 10 06/12/2018
Prepared by: Hermansor�Company LLP — — 03:24PM
DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Aug 1500
COOLINGOADB/WB 86.0'F/67.0'F
HEATING DATA AT DES HTG
HEATING OA DB WB 24.0 *F 19.2 *F
ZONE LOADS
Details
Sensible
Latent
BTU/hr
Details
Sensible
(BTU/hr)
Latent
(BTU/hr)
Window & Skylight Solar Loads
76 ft2
3785
76 ft2
-
Wall Transmission
204 ft2
651
204 ft2
978
Roof Transmission
80 ft2
139
80 ft2
227
Window Transmission
76 ft'
367
76 ft2
1573
Skylight Transmission
0 ft2
0
0 ft2
0
Doorl-oads
0 ft2
0
0 ft2
0
Floor Transmission
80 ft2
55
80 ft2
324
Partitions
0 ft2
0
0 ft2
0
Ceiling
0 ft2
0
0 ft2
0
Overhead Lighting
83W
243
0
0
Task Liqhtinq
0 w
0
0
0
Electric Equipment
200 W
639
-
0
0
7
People
1
184
120
0
0
0
Infiltration
-
0
0
-
1060
0
Miscellaneous
0
0
-
0
0
Safety Factor
0%/0%
0
0
0%
0
0
>> Total Zone Loads
6062
120
4163
0
Zone Conditioning
-
6016
120
-
4102
0
Plenum Wall Load
0%
0
-
0
0
Plenum Roof Load
0%
0
0
0
Plenum Lighting Load
0%
0
0
0
Exhaust Fan Load
0 CFM
0
-
0 CFM
0
-
Ventilation Load
10 CFM
141
39
10 CFM
481
0
Ventilation Fan Load
0 CFM
0
-
0 CFM
0
-
Space Fan Coil Fans
-
0
-
0
Duct Heat Gain / Loss
0%
0
-
0%
0
-
>> Total System Loads
-
6157
159
4582
0
Terminal Unit Cooling
6157
162
0
0
Terminal Unit Heating
0
-
4582
-
>> Total Conditioning
6157
162
4582
Key:
Positive values are cIg loads
Negative values are htg loads
Positive values are htg loads
Negative values are cig loads
Hourly Analysis Program 5.10 Page 4 of 6
Space Design Load Summary for WSF EDMONDS BREAK RM
Project Name: Edmonds WSF Break Rm v5 10 06/12/2018
Prepared by: Hermanso�-Company LLP — — 03:24PM
TABLE 1.1.A. Co ponent Loads For Space "11- WSF Edmonds Break Rm" In Zone "Zone I"
DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Sep 1500
COOLING OA DB / WB 84.0 *F 66.0 *F
OCCUPIED T-STAT 72.0 *F
HEATING DATA AT DES HTG
HEATINGOADB/WB 24.0*F/19.2*F
OCCUPIED T-STAT 70.0 *F
Sensible
Latent
Sensible
Latent
SPACE LOADS
Details
(BTU/hr)
(BTU/hr)
Details
(BTU/hr)
(BTU/hr)
Window & Skylight Solar Loads
76 It'
3956
76 ft'
-
Wall Transmission
204 ft2
606
204 ft'
978
Roof Transmission
80 ft2
105
80 ft2
227
Window Transmission
76 ft2
298
76 ft2
1573
Skylight Transmission
0 ft2
0
0 ft,
0
Doorl-oads
0 ft2
0
0 ft,
0
Floor Transmission
80 ft2
51
80 ft2
324
Partitions
0 ft2
0
0 ft2
0
Ceiling
0 ft2
0
0 ft2
0
Overhead Lighting
83 W
243
0
0
Task Lighting
0 W
0
0
0
Electric Equipment
200 W
639
-
0
0
People
1
184
120
0
0
0
Infiltration
-
0
0
-
1 10601
0
Miscellaneous
0
0
-
01
0
Safety Factor
0%/0%
0
0
0%
0
0
>> Total Zone Loads
6084
120
416�3
0.
TABLE 1.1.13. Envelo Loads For Space "11- WSF Edmonds Break Rm" In Zone "Zone 1"
COOLING
COOLING
HEATING
Area
U-Value
Shade
TRANS
SOLAR
TRANS
(ft')
(BTU/(hr-ft-*F))
Coeff.
(BTU/hr)
(BTU/hr)
(BTU/hr)
N EXPOSURE
WALL
64
0.104
-
90
-
307
WINDOW 1
16
0.450
0.810
63
185
331
S EXPOSURE
WALL
52
0.104
-
236
-
249
WINDOW 1
28
0.450
0.810
110
2252
580
W EXPOSURE
WALL
44
0.104
-
204
-
211
WINDOW 1
16
0.450
0.810
63
958
331
E EXPOSURE
WALL
44
0.104
-
77
-
211
WINDOW 1
16
0.450
0.810
63
560
331
H EXPOSURE
I
ROOF
801
0.0621
-
105
227
Hourly Analysis Program 5.10 Page 5 of 6
System Psychrometrics for WSF EDMONDS BREAK RM —7
Projedt Name: Edmonds WSF Break Rm v5 10 06/12/2018
Prepared by: Hermansor�Company LLP — — 03:24PM
I July DESIGN COOLING DAY, 1500 ::::::D
k CA
Component
Location
Dry -Bulb
Temp
(*F)
Specific
Humidity
(lb/lb)
Airflow
(CFM)
CO2 Level
(ppm)
Sensible
Heat
(BTU/hr)
Latent
Heat
(BTU/hr)
Ventilation Air
Inlet
86.0
0.00978
10
400
136
18
Vent - Return Mixing
Outlet
0.0
0.00000
0
0
-
-
Ventilation Fan
Outlet
0.0
0.00000
01
01
0,
-
Zone Air
73.1
0.00938
331
281
57201
120
Return Plenum
Outleti
0.01
0.00938
3311
281
01
-
AirDensity x Heat Capacity x Conversion Factor.- Atsea level = 1.080; At site altitude = 1.080 BTUI(hr-CFM-F)
AirDensity x Heat of Vaporization x Conversion Factor At sea level = 4746.6; Atsite altitude = 4746.6 BTUI(hr-CFM)
Site Altitude = 0. 0 ft
TABLE 2: ZONE DATA
Component
Location
Dry -Bulb
Temp
(*F)
Specific
Humidity
(lb/lb)
Airflow
(CFM)
CO2 Level
(ppm)
Sensible
Heat
(BTU/hr)
Latent
Heat
(BTU/hr)
Zonel (Cooling)
Ventilation Air
-
-
10
-
Cooling Coil Inlet
73.5
0.00939
331
0
-
-
Cooling Coil Outlet
57.1
0.00931
331
0
5857
130
Heating Coil Inlet
57.1
0.00931
331
0
-
-
Heating Coil Outlet
57.1
0.00931
331
0
0
Zone Air
73-1
0.00938
331
0
5720
Hourly Analysis Program 5.10 Page 6 of 6
A
MECHANICAL ABBREVIATIONS
AMPS IBC INTERNATIONAL BUILDING CODE
MECHANICAL LEGEND
10,xi
RECT SUPPLY AIR DUCT
AC
AIR CONDITIONING
ICW
INDUSTRIAL COLD WATER
10"Xi
UP/TOWARD
ACH
AIR CHANGES PER HOUR
ID
INSIDE DIAMETER/DIMENSION
ACT
ACOUS11CAL CEILING TILE
IE
INVERT ELEVATION
10'XIO"l
RECT SUPPLY AIR DUCT
AD
ACCESS DOOR
IEER
INTEGRATED ENERGY EFFICIENCY RATIO
DN/AWAY
ADDT
ADDITIONAL
imc
INTERNATIONAL MECHANICAL CODE
AFF
ABOVE FINISHED FLOOR
IN
INCHES
10 xio
RECT EXHAUST OR RETURN DUCT
AFG
ABOVE FINISHED GRADE
IN WG
INCHES WATER GAUGE
UP/TOWARD
AHU
AIR HANDLING UNIT
IPLV
INTEGRATED PART LOAD VALUE
ALUM
ALUMINUM
KW
KILOWATTS
lo.xlo:ll
RECT EXHAUST OR RETURN DUCT
AMP/AMPS
AMPERAGE
LAT
LEAVING AIR TEMPERATURE
DN/AWAY
AP
ACCESS PANEL
LB/UBS
POUND/POUNDS
ARCH
ARCHITECT
UF/LIN FT
LINEAL FOOT/FEET
BC
BEADED COLLAR
LPG
LIQUID PROPANE GAS
ROUND DUCT - UP/TOWARD
BDD
BACKDRAFT DAMPER
LPS
LOW PRESSURE STEAM
BF
BELOW FLOOR
LVG
LEAVING
BHP
BRAKE HORSEPOWER
LWA
SOUND POWER RATING LEVEL (IN OB)
ROUND DUCT - ON/ AWAY
BLDG
BUILDING
LWG
LOW WALL GRILLE
BOD
801TOM OF DUCT
LWT
LEAVING WATER TEMPERATURE
FLATOVAL DUCT - LIP/ TOWARD
BOP
BOTTOM OF PIPE
MAX
MAXIMUM
BOT
Els
BOTTOM
BIRD SCREEN / BLACK STEEL
MAU
MEH
MAKE UP AIR UNIT
1000 BRITISH THERMAL UNITS/HOUR
FLATOVAL DUCT - ON/ AWAY
BTU
BRITISH THERMAL UNIT
MCA
MINIMUM CIRCUIT AMPACITY
BTUH
BRITISH THERMAL UNITS PER HOUR
MD
MOTORIZED DAMPER
0@3
DUCT OVERLAP
CAP
CAPACITY
MFR
MANUFACTURER
CEID
CALIBRATED BALANCING DAMPER
misc
MISCELLANEOUS
10*0 T
cc
CONTROLS CONTRACTOR
MIN
MINIMUM/MINUTE
r-110-R-01
BOOT TAP
CD
CEILING DIFFUSER/CONDENSATE DRAIN
MPS
MEDIUM PRESSURE STEAM
CDWR
CONDENSER WATER RETURN
MT
MOUNT
. /N�._
'00
COWS
CONDENSER WATER SUPPLY
MTD
MOUNTED
f7 1
45' TAP
CFM
CUBIC FEET PER MINUTE
MUW
MAKE-UP WATER
CHWR
CHILLED WATER RETURN
NA
NOT APPLICABLE
10"o
CHWS
CHILLED WATER SUPPLY
NC
NORMALLY CLOSED/NOISE CRITERIA
lo"
VOLUME DAMPER
CLG
CEILING
NG/NGAS
NATURAL GAS
COL
COLUMN
NIC
NOT IN CONTRACT
10"01
CALIBRATED BALANCING DAMPER
CONC
CONCRETE
NO
NORMALLY OPEN/NUMBER
2&-
COND
CONDENSATE
NPW
NON -POTABLE WATER
RISE(R) & DROP(D)
CONN
CONNECT/CONNECTED/CONNECTION
N-R
NON-RESIDENTIAL
CONT
CONTINUOUS/CONTINUATION
OA/OSA
OUTSIDE AIR
0
TRANSITION
CONTR
COORD
CONTRACTOR
COORDINATE
OBD
OD
OPPOSED BLADE DAMPER
OUTSIDE DIAMETER/DIMENSION
TURNING VANES/SPLITTERS
COP
COEFFICIENT OF PERFORMANCE
PCF
POUNDS PER CUBIC FOOT
DUCT MOUNTED SMOKE DETECTOR
CT
COOLING TOWER
PD
PRESSURE DROP
CU
CUBIC/CONDENSER UNIT
PH
PHASE
BACK DRAFT DAMPER
CW
DOMESTIC COLD WATER/CONDENSER WATER
POC
POINT OF CONNECTION
FLEXIBLE DUCT
DEI
DUCTBOARD/DRY BLILB/DECIBEL
P/PRESS
PRESSURE
AIR FLOW (FORCED AIR)
DDC
DIRECT DIGITAL CONTROL
PSI
POUNDS PER SQUARE INCH
DEFIL
DEFLECTION
PSIG
POUNDS PER SQUARE INCH GAUGE
DEG
DEGREE/DEGREES
QTY
QUANTITY
DIA
DIAMETER
R
RETURN GRILLE/RELOCATED/RETURN
DMPR
DAMPER
RA
RETURN AIR
COMBINATION FSD
DN
DOWN
RD/RND
ROUND
FIRE DAMPER
DOAS
DEDICATED OUTSIDE AIR SYSTEM
REF
REFERENCE
SMOKE DAMPER
DWG
DRAWING
REQ
REQUIRED
MOTOR OPERATED DAMPER
EXH
EXHAUST
RESID
RESIDENTIAL
EA
EACH
RF
RELIEF
EAT
ENTERING AIR TEMPERATURE
RG
REFRIGERANT DISCHARGE GAS
EC
EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RL
REFRIGERANT LIQUID
ACCESS DOORS
EER
ENERGY EFFICIENT RATING
RPM
REVOLUTIONS PER MINUTE
SOUND TRAP
EF
EXHAUST FAN
RS
REFRIGERANT SUCTION
FLEX CONNECTION
EFF
EFFICIENCY
S
SUPPLY
in 67Xjj 6-0703
ACOUSTICALLY LINED DUCT
EL
ELEVATION
SA
SUPPLY AIR
ou = OUTSIDE DIMENSIONS
ELEC/ELECT ELECTRICAL/ELECTRIC
SAT
SATURATION/SUPPLY AIR TEMPERATURE
SL = SOUND LINING (THICKNESS)
EMCS
ENERGY MANAGEMENT CONTROL SYSTEM
SO
SMOKE DETECTOR
ENT
ENTERING
S/D
SUP & DRIVE CONNECTION
QWZM
FABRIC DUCT
EQUIP
EQUIPMENT
S-C
SEATTLE - CODE
CLEARANCE
ESP
EXTERNAL STATIC PRESSURE
SEER
SEASONAL ENERGY EFFICIENCY RATING
SUPPLY AIR DIFFUSER
EWT
ENTERING WATER TEMPERATURE
SENS
SENSIBLE
(WITH CORE BLANKOFF/ROTATE)
EXIST/(E)
EXISTING
SL
SOUND LINED
EXH
EXHAUST
SM
SHEETMETAL
CEILING RETURN, TRANSFER OR
F
FAHRENHEIT
SPEC
SPECIFICATION
EXHAUST AIR GRILLE
SLOTTED DIFFUSER (PLAN VIEW)
FAC
FIRE ALARM CONTRACTOR
so
SCREENED OPENING
FD
FIRE DAMPER
SOG
SLAB ON GRADE
CD Ax
REVISION CLOUD & TRIANGLE
FDC
FIRE DEPARTMENT CONNEC11ON
SP
STATIC PRESSURE
##'o
ROUND DUCT SYMBOL
FF
FINISHED FLOOR
SF
SQUARE FEET
##xi#"o
FLATOVAL DUCT SYMBOL
FIC
FURNISHED AND INSTALLED BY CONTRACTOR
SS
STAINLESS STEEL
DEGREES SYMBOL
FIO
FURNISHED AND INSTALLED BY OWNER
STRUC
STRUCTURAL
S
POINT OF CONNECTION
FLA
FULL LOAD AMPS
TA
TRANSFER AIR
CD1-100
GIRD TAG IDENTIFIER = TYPE-CFM
FLEX
FLEXIBLE
TEMP
TEMPERATURE/TEMPORARY
8.10
SIZE
FUR
FLOOR
TBD
TO BE DETERMINED
T'STAT/TEMP SENSOR @CARBON DIOXIDE
FOB
FLAT ON BOTTOM
TOD
TOP OF DUCT
SHUMIDITY SENSOR SENSOR
FDIC
FURNISHED BY OTHERS,
TOS
TOP OF STEEL/TOP OF SLAB
SMOKE DETECTOR @CARBON MONOXIDE
FOS
INSTALLED BY CONTRACTOR
FLAT ON SIDE
TOT
TSP
TOTAL
TOTAL STATIC PRESSURE
STATIC PRESSURE SENSOR SENSOR
FOT
FLAT ON TOP
TSTAT
THERMOSTAT
Q OCCUPANCY SENSOR QSENSOR
FP
FIRE PROTECTION
TYP
TYPICAL
FPM
FEET PER MINUTE
UH
UNIT HEATER
FSD
FIRE/SMOKE DAMPER
UNO
UNLESS NOTED OTHERWISE
t7-
-EXISTING DUCTWORK
FT
FOOT/FEET
V
VOLT
FLIT
FUTURE
VD
VOLUME DAMPER
��DEMO DUCTWORK
FV
G
FACE VELOCITY
GRILLE
VEL
VERT
VELOCITY
VERTICAL
'WALL -MOUNTED GRILLE
GA
GAUGE/GALLON
VFD
VARIABLE FREQUENCY DRIVE
o
PIPE ELBOW UP
GALV
GALVANIZED
VOL
VOLUME
PIPE ELBOW DN
GC
GENERAL CONTRACTOR
W
WRAPPED DUCT
DIRECTION OF FLOW
GPM
GALLONS PER MINUTE
WEI
WET BULB
DIRECTION OF SLOPE DOWN
GIRD
GRILLE/REGISTER/DIFFUSER
WG
WATER GAUGE
I
PLUG OR CAP
GWB
GYPSUM WALL BOARD
W/
WITH
PRESS REDUCING ASSEMBLY
HD
HEAD
W/o
WITHOUT
SOLENOID VALVE
HORIZ
HORIZONTAL
W/SF
WATTS PER SQUARE FOOT
PUMP
HP
HORSEPOWER
WSEC
WASHINGTON STATE ENERGY CODE
2--CHVVS/CHWR-5
CHILLED WATER SUPPLY/RETURN
HR
HOUR
RL/RS
REFRIGERANT LIQUID/SUCTION
HSPF
HEATING SEASONAL PERFORMANCE FACTOR
a NO ----S
NATURAL GAS
HIT
HEIGHT
? LPG --- s
LIQUID PROPANE GAS
HWTG
HIGH WALL TRANSFER GRILLE
�-CDWS/CDVVR-5
CONDENSER WATER SUPPLY/RETURN
HWR
HOT WATER RETURN
-HWS/HWR-
HEATING WATER SUPPLY/RETURN
HWS
HOT WATER SUPPLY
2--- COND --- S
CONDENSATE
HX
HEAT EXCHANGER
z Fov ----s
FUEL OIL VENT
HZ
HERTZ
-FOS/FOR-
FUEL OIL SUPPLY/RETURN
2--- ROG
REFRIGERANT DISCHARGE GAS
MECHANICAL GENERAL NOTES
1 . WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 19C. 2015 WSEC, 2015 IMC, &
& SIMILAR YEAR WAC 296-104 BOILER RULES.
2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO.
3. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH
OTHER TRADES. INSTALL IN ACCORDRE WITH APPIRNED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE.
4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK.
5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK DETAILS SHALL BE THE SAME
AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEE� PRIOR TO PROCEEDING.
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO.
7. DUCT SEALING AND CONSTRUCTION TO MEET SIVIACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK
RDOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TcHLET EXHAUSTS, ETC.�. TO MEET 2" CONSTRUCTION STANDARDS WITH
AL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTRE0 OF VAV BOXES, HIGH VELOCTY EXHAUSTS, ETC TO MEET 4" CONSTRUCTION STANDARDS
WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENIETRATIONS TO MEET 6" CONSTRUCTU STANDARDS WITH SEAL CLASS A.
8. ALL CEILING DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING 0 1'. UNO)
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREErS, LOADING DOCK,
NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET.
11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7:
-0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING.
-CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS.
INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED CLASS 1 LOW LEAK (<4 CFM/SF 0 1- WG) DAMPERS (OR
GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE
CONTROL SYSTEM OPERATION.
13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK,
DEADBAND SETTING OF AT LEAST 57 (10-F FOR RESIDENTIAL BETWEEN THE HEATING AND COOUNG SETPOINTS AND
SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. COiROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS
AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4.
14. WHERE REQUIRED BY C408. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNFR
15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE
SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN 1p=1.5 FOR RESTRAINT MENODS OR AS NOTED ON THE DRAWINGS.
REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B.
WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR WAC EQUIPMENT SUPPORTS.
17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE.
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING.
ALL MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NON-COMBUSTIBLE OR SHALL BE UL LISTED AND LABELED FOR INSTALLATION IN PLENUMS OR
AS HAVING A FLAME SPREAD INDEX !� 25 AND A SMOKE -DEVELOPED INDEX OF !� 50.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED IN THE RETURN AIR, PER MECH CODE, SUCH AS HVAC
EQUIPMENT DELIVERING NOT EXHAUSVT >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL
SUPPLY >2000 CFM) O� EACH STO OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, NOT IN SYSTEMS SERVING SINGLE
ROOMSVSPACES. SMOKE DETECTORS SHALL BE FIC�gELECP UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR
L
AS AP LICABLE. VAV BOX (WITH FAN) SHUTDOWN B THROUGH CONTROLS SYSTEM.
20. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED EQUIPMENT AND DEVICE LOCATIONS, UNLESS NOTED
OTHERWISE.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM.
22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/RGOMS, THE FOLLOWING SHALL OCCUR:
-ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC).
-TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALCNG THEIR ENTIRE LENGTH BY GC�.
-ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (84 GC�j LLING WITH ROCK WOOL IS NOT ACCEPTABLE.
-ANY PENETRATIONS OF THE CONSTRUCTION DUCTWORK CONDUIT PIPING
Et SHALL BE EALED ON BOTH SIDES
-ALL DOORS SHALL BE PROVIDEO�ITH TIV FITTING �WETS AUD THRE HO 0 SWEEPS AND OPEN AGAINST THE DIRECTION OF PRESSURE.
-USE SECTION 909.! IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWINd THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION.
6'
23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FIN1SH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ,
24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF;
FLEX DUCT �L L-181 TESTED & NOT 'CONNECTOR"� IS USED DUCT 0 IS INCREASED BY 1 NOMINAL SIZE & BENDS DO NOT EXCEED 235' TOTAL.
REFER TO I TALLATION DETAILS FOR suppofff RE UIREMMS. FLEXIBLE DUCT FLAME SPREAD RAnNG SHALL BE < 25 AND SMOKE DEVELOPED RATING
SHALL BE < 50. USE THERMAFLEX MODEL G-KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL.
25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL- THE ELECTRICAL DESIGN & CONTRACTOR TEAM
WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR
WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTInCATION
READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED.
26. C406 'ADDITIONAL ENERGY PACKAGE OPTIONS' AS APPUCA3LE.
MINIMUM DUCT INSULATION LAST UPDATED 07/11/16
DUCT TYPE
DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM)
INSULATION
R-VALUE
REMARKS
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE: OUTSI� E U DING
R-8
1,2,3
OUTSIDE AIR
WITHIN CONDITIONED SPACE: U.L5ING
SEE NOTES 4 & 5
1,2,3,4,5
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING
R-6
1,2
SUPPLY AIR
<55' OR >105*
WITHIN CONDITIONED SPACE
R-3.3
1,2
; ���;l`R`E�D`A' VA`P0'R 'RETA`R`D,ER(PE`R,M_<, 0.-S)"A,N"D,S,E-AL"E'D"J'O'IN-T,S"",
3 WEATHERPROOF BARRIER REQUIRED AROUND DLCTWORKTC MAINTAIN WATER TIGHTNESS
4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND �'THICK INSULATION MIN.
TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT)
ApIrol[RO
IFILANS M
5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AT[
MINIMUM PIPE INSULATION LAST UPDATED-. 07/11/16
FLUID DESIGN
INSULATION CONDUCTIVITY
NOMINAL PIPE DIAMETER (INCH)
OPERATING
TEMPoF
CONDUCTIVITY
RANGE
I MEAN TEMP
RATING 'F
1 TO I-1/z To
<1-1/2 <4
4TO
<8
8
HEATING SYSTEMS
(STEAM, CONDENSATE,
HYDRO I
T WATER, DOMESTIC
HOT WATER
RECIRC)
>350
0.32-0.34
250
4.5
5.0
5.0
5.0
2!��9o();32
200
3.0
4.0
4.5
4.5
4.5
0 7-0.30
ISO
3
2.5
3.2
3.0
141-200
0.25-0.29
125
11,
IN'
2.0
2. 0
2.0
105-140
0.21-0.28
100
1.0
1 1.0
1.5
1.5
1.5
DOMESTIC COLDWATER
AND HORTZONTW
R
CUr
DENSATION)
N/A
1 0.21-0.27
1 75
1 0.5 1 0.5 0.5
0.5 0.5
COOLLNG SYSTEMrS (CLI.LLED ATER, BRINE REFRIGERANT. WATERS11DE COO.CMIZER
40_60 0 2 _0.27 T
AND
7
5 O.�
5
fLTEMS)*.
1.0
1
'I.-os
<41 1 0.20-0.26
NOTE:
75 0.5
1 1.0
.0
Ho
NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING I" OR LESS IN DIA.
TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS.
Om JOB
DRAWING INDEX
SHEET NO.
SHEET TITLE
CURRENT
REVISION
MO.00
LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - WAC
M2.01
1ST FLOOR PLAN & SCHEDULES - WAC
ROOF OLITHNF
am
REFRIG�R�WTE >SErS,
SEE SUBMITTALS FOR SIZES.
CONNECT NEW rCONDENSATE TO
EXISTING CONDENSATE PIPING
1ST FLOOR PLAN - HVAC
SCALE, 1/2" = 1'-0'
KEY PLAN
SCALE: NONE
SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE
LAST UPDATED' 06/06/18
UNIT
MOUNTING/
I
BASI OF
AS OCIATED
SUPPLY
OSA
ESP
MLAIXN RFTR
H%ER
ELECTRICAL
- — - 6��UND
WEIGHT
TAG
LOCATION
SERVES
C EN
OND SER
L CFM
CFM I
IN IAIG
E
FLA
1 V/PH
dBA
I LEIS
I REMARKS
FCU-1
WALLHUNG
I BREAK RIM
L09NAI
HP-1
IML170/237/321/3991
NA
I INA
40
NA
1 0.75
1 208-23PL1
119/22/30137/431
. 2:
ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER
MANUFACTURERS REQUIREMENTS
ELECTRICAL CONTRACTOR TO PROVIDE SOCIR PROTECT -ION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE.
MANUFACTURER TO PROVIDE SCCR LISTING (S KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. PROVIDE WITH WALL -MOUNTED WIRELESS PROGRAMMABLE T'STAT, REFER TO MFGS REQUIREMENTS FOR REFRIGERANT PIPE SIZES
INDOOR UNIT POWERED FROM OUTDOOR UNIT BY ELECTRICAL CONTRACTOR
TERMINATE CONDENSATE LINE OUTSIDE THE BUILDING WHERE IT WONT CREATE NUISANCE
ECONOMIZER EXEMPT PER 2015 WSEC C403.3.3 EXCEFrION 3 (UNIT IS 64% MINIMUM HIGHER EFFICI[ENCY THAN THE 14 SEER REQUIREMENT IN TABLE C403.2.3(l & 2))
SPLIT SYSTEM OUTDOOR HEAT PUMP UNIT SCHEDULE
LAST UPDATED: 06/06/18
UNIT
TAG
MOUNTING/
L
AREA
I SE RVED
13� 'IS
S�
OF E'IGN
ASSOCIATED I
FAN COIL
COOLING LALACITY
BTUH
HEATING
CAPACITY
ELECTRICAL
SOUND
dBA
I WEIGHT
LEIS
REMARKS
TED T RANG,
9EER
1 BTUH
1 RAN
Cop
I MCA
I WPH d
HP-1
GROUND
I BREAK RM
MITSUBISHI MUZ-GL09NAI
FCU-1
1 9,000 13600-12200
1 24.6
1 10,900
_
;5,13111
4.44
1 9.0
1 208-23011
1 so 1
81
1 1-7
GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER
MANUFACTURERS REQUIREMENTS
REMARKS:
1 ELECTRICAL CONTRACTOR TO PROVIDE SOCIR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE, PRIOR TO ORDER.
MANUFACTURER TO PROVIDE SCCR LISTING (S KAIC MINIMUM OR PER ELEC17RICAL CONTRACTOR CALCULATION) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 SPLIT SYSTEM UNITS REQUIRE DISCONNECT AT THE ROOF CONDENSING UNIT BY ELECTRICAL CONTRACTOR
3 INVERTER DRIVEN COMPRESSOR, TEST CONDITIONS BASED ON AHRI 210/240
4 SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES FOR EACH UNIT CONNECTION, WIND BAFFLE, LOW AMBIENT
OR HEAD PRESSURE CONTROL SUITABLE FOR LOW AMBIENT COOLING - ADDITIONALLY, CONFIRM CONTROL WIRE GAUGE (14 OR 16 AWG) WITH SUBMITTALS PRIOR TO INSTALLATION TO INDOOR UNIT
5 REFRIGERANT: R-410A. PROVIDE ADDI[TIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS
6 PROVIDE COATING FOR MARINE ENVIRONMENT
7 ECONOMIZER EXEMPT PER 2015 WSEC C403.3.3 EXCEPTION 3 (UNIT IS 64% MINIMUM HIGHER EFFICIENCY THAN THE 14 SEER REQUIREMENT IN TABLE C403.2.3(l & 2))
011
Hermanson
Building Today, Defining Tomorrow
Herrn'nson Company ULP
1221 2rd Avenue North
Kent Washington 98032
Tel; (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg J: HERMACLDOSW
WASHINGTON STATE
FERRY - EDMONDS
BREAK ROOM SS
119 SUNSEr AVE. S.
EDMONDS, WA 98020
OD
WA
36149
AL
Revisions
06/13/10 MG ISSUE FOR PERMIT
No. Date By Description
Design Team
D.sign MG
Drawn FVP
Checked DTN
ore -Construction Number 14-18-12959
Construction Number
Issue Date 05/13/18
1ST FLOOR PLAN
& SCHEDULES
HVAC
M 2,11 . 0 1
RECEIVED
JUN 14 2019
I..P.r.T RIF.I.. I ISSU, E FOR PERMIT