APPROVED BLD PLN RESUB1 BLD2021-1266+Architectural_or_Building_Floor_Plans+10.12.2021_9.00.13_AM+24568752 3 4 7 10 12 13 14 15 16 A C � �� �� �� G ■�1 J K L PROJECT GENERAL NOTES I PROJECT DATA -TENANTIMPROVEMENT- 550 Main Street S., Edmonds, WA 98020 1. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF OTHER CONSTRUCTION TYPE: EXISTING CONSTRUCTION TYPE: DISCIPLINES: STRUCTURAL, ELECTRICAL, MECHANICAL AND TYPE V-B FULLY-SPRINKLERED PLUMBING. 2. DO NOT SCALE DRAWINGS- USE DIMENSIONS ONLY. OCCUPANCY GROUP: PRIMARY OCCUPANCY: � -BAKERY 3. DIMENSIONS WHERE SHOWN ARE NORMALLY GIVEN: A. TO COLUMN CENTER LINE APPLICABLE CODES: 2018 InternatlOnal BUllding Code (IBC) B. To FINISH FACE of CMu oR GWB. 2018 International Existing Building Code (IEBC) 4. DIMENSIONS SHOWN ON LARGER SCALE DRAWINGS GOVERN. 2018 InternatlOnal ReSldentlal COde (IRC) 5. FIELD VERIFY ALL EXISTING CONDITIONS. REVIEW EXISTING CONDITIONS PRIOR TO COMMENCING THE WORK, NOTIFY 2018 International Mechanical Code (IMC) ARCHITECT OF UNEXPECTED CONDITIONS. 2018 International FU@I Gas Code (IFGC) 6. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB, 2018 International Fire Code (IFC) UNLESS NOTED OTHERWISE. 2018 UnlfOrm PlUmbing Code (UPC) 7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD 2020 National Electric Code (NEC) TO MEAN TO ALIGN THE FINISH MATERIAL OF THE WALLS OR COLUMNS INDICATED. 2009 Accessible &Usable Buildings &Facilities 8. ALL INTERIOR GYPSUM WALL BOARD IS 5/8 " TYPE X GWB ON (ICC/ANSI A117.1) METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR LOCATION OF WATER RESISTANT GWB. 9. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILET ROOMS, OCCUPANCY: B -BAKERY WAREWASH AND WET AREAS. 797 SF / 150 (CUSTOMER) = 5.31 OCCUPANTS 10. ALL FINISH CEILING HEIGHTS SHALL BE CONFIRMED UNLESS 799 SF / 200 (KITCHEN) - 3.99 OCCUPOANTS NOTED OTHERWISE ON THE ROOM FINISH SCHEDULE. 11. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK. TOTAL OCCUPANT LOAD: 9.3 - 10 OCCUPANTS 12. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR ONLY (1) EXIT REQUIRED (2) PROVIDED APPLICABLE JURISDICTION. ONLY (1) HC TOILET REQUIRED 13. PROVIDE ONE TYPE 5E-2A-10BC FIRE EXTINGUISHER PER 3,000 SF AND NOT MORE THAN 75 FT OF TRAVEL DISTANCE. 14. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED, SEPARATE SUBMITTALS PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATED PARTITIONS. 15. WHERE HVAC OR OTHER MECHANICAL ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE SIGNAGE UNDER SEPARATE SUBMITTAL. BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO FIRE SPRINKLERS AND FIRE ALARM UNDER A SEPARATE PERMIT PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH MECHANICAL/ELECTRICAL AND PLUMBING UNDER SEPARATE PERMIT RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. SCOPE OF WORK 16. ALL CHANGES IN PROJECT SCOPE DUE TO CONTRACTOR GENERATED ALTERNATES OR EXISTING FIELD CONDITIONS SHALL BE TRANSMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. BUILDING: 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND INSTALLING OF OWNER FURNISHED ITEMS THE WORK INCLUDES, BUT NOT LIMITED TO TENANT IMPROVEMENTS FOR A LISTED, UNO. BAKERY AND RELATED SERVICES, WORK INCLUDES NON-STRUCTURAL WALLS, 18. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. FINISHES 19. MODIFY THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL ON SITE: GOVERNING ORDINANCES AND LANDLORD CRITERIA. NONE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. 20. SPRINKLER HEADS MOUNTED IN HARD (GWB) CEILINGS TO BE FULLY RECESSED WITH WHITE CAPS. LEGAL D E S C R I PT I O N 21. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER RATING CRITERIA. 22. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD PARCEL NUMBER: 004342-120-015-00 AND 004342-120-017-00 CRITERIA AND LOCAL CODES AS REQUIRED. (BEING COMBINED UNDER SEPARATE APPLICATION) 23. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. LEGAL: 24. PROVIDE FINISH FLOOR UNDER ALL EQUIPMENT AND LOTS 15 AND 16, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING CASEWORK. TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. FOR ADDITIONAL ABBREVIATIONS SEE OTHER DESIGN DISCIPLINES ARCHITECTURAL ABBREVIATIONS PROJECT DIRECTORY ARCHITECT: smith co Ilc 603 STEWART STREET SUITE 610 SEATTLE, WA 98101 M: 206.713.4076 T: 206.466.5239 PROJECT MANAGER: Keith Smith E-Mail:ksmith@smithco.org OWNER: COPPERPOT BAKERY Approved by Fire 10/28/2021 AFM fC��ttel'el' Separate permits for sprinkler and fire alarm alterations, type 1 hood needs to be interconnected to fire alarm and gas shunt. System needs to be L�Ddated � Tearis, Fire for.final � � � � ,� CROSS CONNECTION REVIEW TO BE DONE WITH PLUMBING PERMIT DRAWING INDEX ARCHITECTURAL T-1.0 GENERAL INFORMATION T-2.0 CODE INFO - ADA T-3.0 EGRESS PLAN T-4.0 SITE PLAN A-1.0 CONSTRUCTION PLAN A-1.1 DIMENSION FLOOR PLAN A-1.2 NOT USED A-1.3 FLOOR FINISH PLAN A-1.4 REFLECTED CEILING PLAN A-2.0 ENLARGED TOILET PLAN/ELEVATIONS A-2.1 INTERIOR ELEVATIONS A-3.0 DETAILS ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED K-1.0 EQUIPMENT PLAN/EQUIPMENT SCHEDULE APPROVED BY PLANNING PLANS MUST BE ����� ON JOB SITE VICINITY MAP 8 _ ar ,.-'' - s ,rims, sa Edmonds P OJECT a. Community Gaspers s, Gaspers St � Ma Iewood ParentQ Edmonds un e P a zomnssw Col©ge Separate permits required: PrOJeCt $Ite Methodis Ch c g Cooperative L��ATION � s >o,., s, sw � Mechanical Brackett's T H B O W L g ,; W f g City of Lynnwood 0 1., Landing OF DMONDS n � _ zoznassw ca.aw,y n ,�znJV11W MunicipalGolfCourse - - PIUmUIng Shoreline ,.� = > � � ; Sanctuary._ � > I '_ L Walk in Coolers/Freezers Edm Forth eArts � cie^ sr ci.^ s, �� s, arse sw s za3re s, sw Pine Ridge � 1pd Brackett's o ays - 20 n,l.rs oairyst �_.F!aik saams,sw � Landing North � -Civic [� Q Rory'snf Edmonds ��,, �eyr enter Villa Riverola Q 3 Sm.V+•S, Spioque 5f - o Playfletd msmeisw £ � � e PinPark ' � r District Coun o College Place © South Division 9e zoamssw Middle School V C 1tJ O f E d m o n d s Edmon S.Kingstop 'z - Ferry � ll Booth / © �.-�ondsQ � 550 �__ � z- � ; g - �' - � aMA � ' ' '�' °J'� s � s �'y Main Street � z o � � United States �' � Postal Service �� -_. _ M: - - - --------- �----------►----------�------ -... F 9 Zaat�s,sw Building Department w o.y,ons Dayton st� i� � . HAUL ROUTE � HAUL ROUTE - z zaern Pf sw � a s .ham SquereQ N Mep�as, u is Club / H M,pi«s Yost PoolQ. � Caffe Ladro Edmon s © �i° zimnsisw � Work T/I \ y A � �OJ f e«.,^ G�rardPs Ost�rja -�• � � � � - \ � Yost Park- � �- / waiams, �:--•'l s"'`+y, a s Burger King J s ��/ 99 Address --- 550 MAIN ST . Edmonds Shelleherger �,p_ Marsh � - � ��� g � ° Bar Dojo z,2tnstsw{ __________;_�______'______�gir:.7da creek t. w sa�as� � por0way ; - ° spwa°st E HAUL ROUTE i HAUL ROUTE Max Dods-WoodwayQ t j ______________________________ `-----------------------------------------------� Edmonds � _ � � �`"' T High School � � Owner COPPERPOT BAKERY ; City Park a .`.� taermens way „ ti N �° � Nemioa st n g a a Q ra z, em ai sw > s � � ., m ztsm s, sw J z,s,a�,=w �Q ------------------------------- - - - - a� K y m towel st sm 9w � > � a. A a. � � � � W - Q Chase Lake a Eleinenlary Sdhgnt. SWedISh© f __ _ ___ --- Approved Date p�^e� nme s< rarest zyam st sw � ztemAsw z,am st sw PaclficSalmonQa�amnsw Edmonds Campus w _ ztz,nssw PremeraBlveCro rnawan we > ra,symrap - > , V z„es^w � H - r,rs z,�mrsw z,e<ns,sv z,tnns,sw p �� . Building Official �Elr� L%la-Y1�Q-tr o �' F 3 Y w WinGo FOOdSo .� � '---------------"" PINE PARK < >< � � ,:., un NEIGHBORHOOD � a Quo s f ---------------------------- ' Permit Number � BL D2 0 21-12 6 6 rims, -Westgate 0 2201h St SYV 220th St sw a m 220th � sw Edmonds Family V Scott, s<sw m Fun Center ' ' ioe� eimw,y Elementary School � .. $ u d � � � 3 0 ` < 9 � p � .. Y . -------------------------- n � m V o ut � ` � � F � 4 � i ' °'d _ eacnst a � � 4 Fr !-�' C, I S�.ra E.�' N.�.�I.w e '°w f a h: � P2,k - :?din St ��v. :d:l� 5: SW ARCHITECTURAL SYMBOLS SYMBOLS ACOUS. ACOUSTICAL ELEV. ELEVATION L. LONG, LENGTH PR. PAIR T.O.S. TOP OF STEEL NORTH ARROW ADJ ADJUSTABLE, ADJACENT ELEC. ELECTRICAL LAM. LAMINATE, LAMINATED PROJ. PROJECT T.O.W. TOP OF WALL DETAIL DETAIL IDENTIFICATION PROJECT NORTH � � ITEM S.I.O A.F.F. ABOVE FINISHED FLOOR (SLAB) ENCL. ENCLOSURE L.F. LINEAR FOOT, LINEAL FOOT PRV PRESSURE REDUCING VALVE T&B TOP AND BOTTOM CUT LINE -DEFINES THE ARROW �� REVISION CLOUD � � OR N.I.C. ALUM ALUMINUM EQ. EQUAL LIQ. LIQUID P.T. PRESSURE TREATED TEL. TELEPHONE 3 DETAILED ELEMENT � AND DELTA ANOD. ANODIZED EXH. EXHAUST L.P. LOW POINT Q.T. QUARRY TILE TEMP. TEMPERED GLASS TRUE NORTH APPROX. APPROXIMATE EXIST. EXISTING LT.WT. LIGHT WEIGHT QTR. QUARTER TYP. TYPICAL A8.01 INDICATOR BD. BOARD EXP. EXPANSION MAS. MASONRY R RADIUS UTIL. UTILITY SHEET WHERE ITEM S.O.I.0 B.F.F. BELOW FINISHED FLOOR (SLAB) EXT. EXTERIOR MAX. MAXIMUM R.C. REFRIGERATION CONTRACTOR U.B.C. UNIFORM BUILDING CODE DRAWN DOOR MARK 50'-0" A.F.F. WORK, CONTROL OR S.I.C. BLDG. BUILDING F.D. FLOOR DRAIN M.B.S. METAL BUILDING SUPPLIER R.C.P. REFLECTED CEILING PLAN U.N.O. UNLESS NOTED OTHERWISE OR DATUM POINT BLK. BLOCK FDN. FOUNDATION MECH. MECHANICAL R.D. ROOF DRAIN V.C.T. VINYL COMPOSITION TILE WALL SECTION DOOR CODE - BLK'G. BLOCKING FF FACTORY FINISH MFG. MANUFACTURING R.L. ROOF LEADER VERT. VERTICAL DETAIL IDENTIFICATION REFER TO 2580A SLOPE DIRECTION BM. BEAM FHS FLAT HEAD SCREW MFR. MANUFACTURER REC'D. RECEIVED V.I.F. VERIFY IN FIELD SCHEDULE NEW CONSTRUCTION -SHOWN SOLID BOT. BOTTOM FL. FLOOR M.H. MANHOLE REFRIG. REFRIGERATION W/ WITH CUT LINE -DEFINES THE SLOPE DOWN WITH DATUM MARK BTWN. BETWEEN F.I.O. FURNISHED AND INSTALLED MIN. MINIMUM REINF. REINFORCING W/O WITHOUT 2 DETAILED ELEMENT WINDOW, RECITE OR 1/8" PER FOOT CB CATCH BASIN BY OWNER M.I.P. METAL INSULATTED PANEL REQ'D. REQUIRED WD. WOOD A7.01 LOUVER MARK C.G. CORNER GUARD FIN. FINISH MISC. MISCELLANEOUS R.O. ROUGH OPENING WDW. WINDOW _SHEET WHERE DRAWN WINDOW C.I. CAST IRON F.R.P.P. FIBER REINFORCED PLASTIC M.O. MASONRY OPENING SCHED. SCHEDULE WHS. WELDED HEAD STUD � SPRINKLER MAIN C.I.P. CAST IN PLACE PANELS) M.R. MOISTURE RESISTANT S.C. SOLID CORE W.P. WATERPROOF 14 NUMBER -REFER C.L. CENTER LINE FRT. FIRE RETARDANT TREATED MULL. MULLION SHT. SHEET W.R. WATER RESISTANT BUILDING SECTION TO SCHEDULE CLR. CLEAR FTC. FOOTING MTD. MOUNTED SIM. SIMILAR WT. WEIGHT DETAIL IDENTIFICATION ' EXISTING CONSTRUCTION TO REMAIN CLG. CEILING GA. GAUGE MTG. MOUNTING S.I.O. SUPPLIED AND INSTALLED W.W.F. WELDED WIRE FABRIC 6 EQUIPMENT MARK �� PROPERTY LINE -SHOWN LIGHT BACKGROUND CMU CONCRETE MASONRY UNIT GALV. GALVANIZED MTL. METAL BY OWNER Y.D. YARD DRAIN EQUIPMENT COL. COLUMN G.C. GENERAL CONTRACTOR N.I.C. NOT IN CONTRACT S.I.V. SUPPLIED AND INSTALLED A3.01 SHEET WHERE DRAWN � � � � CONC. CONCRETE GWB GYPSUM WALLBOARD, GYPSUM NOM. NOMINAL BY VENDOR NUMBER -REFER CONT. CONTINUOUS BOARD N.T.S. NOT TO SCALE S.O.I.C. SUPPLIED BY OWNER INSTALLED 24 TO SCHEDULE FENCE CONSTR. CONSTRUCTION H.B. HOSE BIBB O.A. OVERALL BY CONTRACTOR EXTERIOR ELEVATION CONTR. CONTRACTOR H.C. HANDICAPPED O.C. ON CENTER SQ. SQUARE DETAIL IDENTIFICATION ROOM MARK X X X C.T. CERAMIC TILE H.M. HOLLOW METAL O.D. OVERFLOW DRAIN S.S. SERVICE SINK, SANITARY SEWER 8 DBL DOUBLE HORIZ. HORIZONTAL O.H. OVERHEAD SST STAINLESS STEEL ROOM ---ROOM NAME EXISTING CONSTRUCTION TO BE DIM. DIMENSION H.P. HIGH POINT OP'G OPENING STD. STANDARD A3.02 SHEET WHERE DRAWN 100 ROOM NUMBER BREAKLINE REMOVED -SHOWN DASHED DTL. DETAIL HT. HEIGHT OPP. OPPOSITE STL. STEEL D.F. DRINKING FOUNTAIN HTR. HEATER PTN. PARTITION STRUCT. STRUCTURE, STRUCTURAL ^ D.S. DOWNSPOUT HVAC HEATING, VENTILATION, AND PERP. PERPENDICULAR SUSP. SUSPENDED INTERIOR ELEVATION L COLUMN GRIDS WALL TYPE MARK DWG. DRAWING AIR CONDITIONING PL. PLATE, PROPERTY LINE SYS. SYSTEM DETAIL IDENTIFICATION EA. EACH IBC INTERNATIONAL BUILDING CODE PLAS.LAM. PLASTIC LAMINATE T TREAD, TOP E.F.S. EXTERIOR FINISH SYSTEM INSUL. INSULATION PLYWD. PLYWOOD T.O.J. TOP OF JOIST WALL TYPE E.I.F.S. EXTERIOR INSULATION AND INT. INTERIOR PLBG. PLUMBING T.O.M. TOP OF MASONRY 5.03 6 � 0 FE FIRE EXTINGUISHER FINISH SYSTEM JT./JTS. JOINT, JOINTS PNL. PANEL, PANELING T.O.P. TOP OF PARAPET SHEET WHERE DRAWN X X- NOTE 7 MATERIALS 0 GYPSUM BOARD CONCRETE II�I�ITII EARTH �� GRAVEL ® CMU OR BRICK PLYWOOD RIGID INSULATION ® BATT INSULATION WOOD MEMBER WOOD BLOCKING Jim FINISHED WOOD ® ACOUSTICAL TILE STEEL ® ALUMINUM E.I.F.S. _ SOUND INSULATION A B Main Street Commons 550 Main Street Edmonds, WA 98020 �� � C 603 Stewart Street suite 610 Seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ D Consultant E F G BLD2021-1266 Consultant R®iar� 10/12/2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Architect Registration 6294 H Issues and Revisions No. Date Issues 1 09�15�21 PERMIT 2 10�12�21 PERMIT C�RRECTI�NS I J Project Name Project Number 02016063.01 Description COVER SHEET K Computer File T1.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. f'� 3 4 5� 6 7 8 9 10 11 12 13 14 15 16 T-1.0 C I�� E F L ICI J K L 1 2 3 4 SITE DEVELOPMENT: 1. SURFACE SLOPES OF PARKING SPACES FOR THE PHYSICALLY DISABLED SHALL NOT EXCEED 1/4-INCH PER FOOT IN ANY DIRECTION. 2. PEDESTRIAN WAYS THAT ARE ACCESSIBLE TO THE PHYSICALLY DISABLED SHALL BE PROVIDED FROM EACH DISABLED PARKING SPACE TO RELATED FACILITIES, INCLUDING CURB CUTS OR RAMPS AS REQUIRED. 3. THE SURFACE OF EACH PARKING SPACE SHALL HAVE A SURFACE IDENTIFICATION DUPLICATING THE SYMBOL OF ACCESSIBILITY CONSISTING OF A WHITE FIGURE ON A BLUE BACKGROUND, AT LEAST 3 FEET SQUARE. PROPORTIONS INTERNATIONAL SYMBOL OF ACCESSIBILITY . ///'. DISPLAY CONDITIONS INTERNATIONAL SYMBOL OF ACCESSIBILITY 1 6" � 42" N 5 6 z � � � o � �, z 7 MINIMUM PASSAGE WIDTH FOR ONE WHEELCHAIR AND ONE AMBULATORY PERSON THE COUNTER SLOPE OF ADJOINING GUTTER AND ROAD SURFACE IMMEDIATELY ADJACENT TO CURB RAMP OR ADJOINING SURFACES SHALL ACCESSIBLE ROUTE NOT EXCEED 1:20 X=12 SHALL NOT BE STEEPER THAN 1:20 Y=1 LEVEL LANDING MEASUREMENT OF CURB RAMP SLOPES 4 A 24" WIDE TACTILE PATTERN OF RAISED TRUNCATED DOMES COMPLYING WITH SECTION 705.3.3.3 THRU 705.3.1.3 OF ICC/ANSI SHALL BE PROVIDED ON THE WALKING SURFACE AT THE RETAINING WALL IF NECESSARY PLATFORM EDGE, TYPICAL � AT EDGE OF SIDEWALK � BUILDING OR LANDSCAPING LINE � o � � 8.33% `� 8.33% z �� � � o 0 0 oho oho oho oho � 000 000 STREET 48" MINIMUM SIDEWALK CURB CJ � � BUILDING OR LANDSCAPING LINE � A 24" WIDE TACTILE PATTERN OF RAISED TRUNCATED DOMES COMPLYING WITH SECTION 705.3.3.3 THRU 705.3.1.3 OF ICC/ANSI SHALL BE PROVIDED ON THE � WALKING SURFACE AT THE PLATFORM EDGE WHEN CROSSING PARKING, TYPICAL o � M � ch X ao ODODv ODODO 00000000000 0 0 0 0 0 0 10% ����������� 10% _ o0000000000 �'. SIDEWALK CURB 6 WHERE BOTH CLOSER AND LATCH ARE PROVIDED � �f � I II � I DIMENSIONS OF ADULT -SIZED WHEELCHAIRS � � 12" min.* v I 18"min I I CURB RAMPS, WALKS AND SIDEWALKS: 2 4. WALKS AND SIDEWALKS SHALL HAVE CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2-INCH AND SHALL BE A MINIMUM OF 48-INCHES IN WIDTH. - (A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE 5. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL (5%GRADIENT) IT SHALL COMPLY WITH THE PROVISIONS FOR PEDESTRIAN RAMPS. � � 6. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4-INCH PER FOOT. 7. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED - 1/2-INCH. WHEN CHANGES IN LEVELS DO OCCUR, THEY SHALL NOT BE BEVELED o �� WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT 42" min "' EXCEEDING 1/4-INCH MAY BE VERTICAL. 36" min 8. WHEN CHANGES IN LEVELS GREATER THAN 1/2-INCH ARE NECESSARY, THEY SHALL COMPLY J --- WITH THE REQUIREMENTS FOR CURB RAMPS &PEDESTRIAN RAMPS. 9. NOT USED (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PUSH SIDE 10. CURB RAMPS SHALL BE CONSTRUCTED AT EACH CORNER OF STREET INTERSECTIONS AND WHERE A PEDESTRIAN WAY CROSSES A CURB. 11. CURB RAMPS SHALL BE A MINIMUM OF 4 FEET IN WIDTH AND SHALL LIE � 54" MIN GENERALLY, IN A SINGLE SLOPED PLANE, WITH A MINIMUM OF SURFACE � - - - - � WARPING AND CROSS SLOPE. � Z I I 12. THE SLOPE OF CURB RAMPS SHALL NOT EXCEED 1 VERTICAL TO 12 � � HORIZONTAL. THE SLOPE OF THE FANNED OR FLARED SIDES OF CURB � � i 24" min RAMPS SHALL NOT EXCEED ONE VERTICAL TO 10 HORIZONTAL. 13. A LEVEL LANDING 4 FEET DEEP SHALL BE PROVIDED AT THE UPPER END OF EACH CURB RAMP OVER ITS FULL WIDTH TO PERMIT SAFE EGRESS FROM THE RAMP SURFACE, OR THE SLOPE OF THE FANNED OR FLARED SIDES OF THE CURB RAMP SHALL NOT EXCEED ONE VERTICAL TO 12 HORIZONTAL 14. THE LOWER END OF EACH CURB RAMP SHALL HAVE A 1/2-INCH COUNTER SLOPE IMMEDIATELY ADJACENT TO RAMP OR ACCESSIBLE ROUTE SHALL NOT BE STEEPER THAN 1:20 (E) HINGE APPROACH, PUSH SIDE (F) LATCH APPROACH, PULL SIDE 15. THE SURFACE OF EACH CURB RAMP AND ITS FLARED SIDES SHALL BE � � SLIP -RESISTANT AND SHALL BE OF CONTRASTING FINISH FROM THAT OF THE ADJACENT SIDEWALK. 16. 24"WIDE TACTILE PATTERN OF RAISED TRUNCATED DOMES COMPLY WITH i z SECTIONS 705.3.1.1 THRU 705.3.1.3 SHALL BE PROVIDED ON THE WALKING � SURFACE AT PLATFORM EDGE � 24"MIN *48" MIN WHERE CLOSER IS PROVIDED (G) LATCH APPROACH, PUSH SIDE MANEUVERING CLEARENCE AT SWINGING DOORS 7 2 3 4 5 6 7 8 9 10 ENTRANCES: 17. PROVIDE AT METALLIC SIGN OVER EACH STOREFRONT DOOR STATING: "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS". LETTERS SHALL NOT BE LESS THAN 1"HIGH ON A CONTRASTING BACKGROUND. THE SIGN SHALL BE INSTALLED BY THE GENERAL CONTRACTOR ON THE STOREFRONT ALUMINUM HEADER FRAME. 18. ALL NEW PRIMARY ENTRANCES TO THE BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED. 19. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 20. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET-8 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF DOORWAY IS NOT LESS THAN 32-INCHES. 21. WHERE PAIR OF DOORS IS UTILIZED AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 22. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN PATH OF TRAVEL SHALL BE OPENABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, THAT DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF WRIST TO OPERATE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. REFER TO SECTION 404.2.7 OF IBC 23. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34-INCHES MIN AND 48" ABOVE THE FLOOR. 24, THE FLOOR AND LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH OF 60 INCHES IN THE DIRECTION OF TRAVEL AND THE LENGTH OF 48 INCHES IN OPPOSITE DIRECTION OF TRAVEL. SEE DIAGRAM "MANEUVERING CLEARANCE" 25. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND 24-INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18-INCHES PAST THE STRIKE EDGE FOR THE INTERIOR DOORS. 26. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2-INCH LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4-INCH AND 1/2-INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 27. THE BOTTOM 10-INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING DOORS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10-INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSHED SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. 28. A NARROW FRAME WITH A BEVELED TOP (30 DEGREES MAX. BEVEL TO VERTICAL PLANE) INSTALLED AT THE BOTTOM OF THE GLASS DOOR (WITH NO SIDE FRAMES) MAYBE USED IN LIEU OF PROVIDING THE REQUIRED 10-INCH UNINTERRUPTED SURFACE AT THE BOTTOM OF THE DOOR. 29. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. FOR EXTERIOR DOORS AND 5 LBS. FOR INTERIOR DOORS. SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15 LBS. CORRIDORS AND AISLE: 30. FLOOR SURFACES SHALL BE SLIP -RESISTANT. 31. EVERY PORTION OF EVERY BUILDING IN WHICH ARE INSTALLED SEATS, TABLES, MERCHANDISE, EQUIPMENT OR SIMILAR MATERIALS SHALL BE PROVIDED WITH AISLES LEADING TO AN EXIT. 32. EVERY AISLE SHALL BE NOT LESS THAN 3 FEET WIDE IF SERVING ONLY ONE SIDE, AND NOT LESS THAN 3 FEET 8 INCHES WIDE IF SERVING BOTH SIDES. SUCH MINIMUM WIDTH SHALL BE MEASURED AT THE POINT FARTHEST FROM AN EXIT, CROSS AISLE OR FOYER AND SHALL BE INCREASED BY 1 1/2 INCHES FOR EACH 5 FEET IN LENGTH TOWARD THE EXIT. CROSS AISLE OR FOYER WITH CONTINENTAL SEATING SIDE AISLES SHALL BE NOT LESS THAN 44 INCHES IN WIDTH. SANITARY FACILITIES: 33. ACCESSIBLE SIGN CONTAING TACTILE CHARACTER IS PROVIDED AT DOOR, THE SIGN SHALL BE ALONGSIDE THE DOOR ON LATCH SIDE AND AT DOUBLE DOORS, THE SIGN SHALL BE RIGHT OF THE RIGHT HANDED DOOR. THE SIGN CONTAINING TACTILE CHARACTERS SHALL HAVE 18" MIN BY 18" MIN. SPACE ON THE FLOOR CENTERED ON SIGN. THE SIGN TACTILE CHARACTER SHALL BE 48"MIN AND 60" MAX ABOVE FLOOR. 34. CLEARANCE AROUND THE WATER CLOSET SHALL BE 60" MIN MEASURED PERPENDICULAR FROM THE SIDEWALL, AND 56" MIN. MEASURED PERPENDICULAR FROM REAR WALL. NO OTHER FIXTURES OR OBSTRUCTION SHALL BE WITHIN WATER CLOSET CLEARANCE 35. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC CLOSING DEVICE, AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WHEN LOCATED AT THE END AND 34-INCHES WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 36. EXCEPT FOR DOOR OPENING WIDTH AND DOOR SWINGS, A CLEAR UNOBSTRUCTED ACCESS NOT LESS THAN 44-INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN 48-INCHES AS MEASURED AT RIGHT ANGLES TO THE COMPARTMENT DOOR IN IT'S CLOSED POSITION. 37. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHES AND A MAXIMUM OF 19 INCHES MEASURED TO THE TOP OF TOILET SEAT. 38. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44-INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. 39. WHERE URINALS ARE PROVIDED, AT LEST ONE SHALL HAVE A CLEAR SPACE 30-INCHES WIDE X 48-INCHES LONG IN FRONT OF THE URINAL. 40. WHERE URINALS ARE PROVIDED, AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE PROVIDED. 41. A CLEAR FLOOR SPACE 30-INCHES WIDE X 48-INCHES LONG SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. 8 I 9 I 10 11 12 13 42. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29-INCHES FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30-INCHES IN WIDTH WITH 8-INCHES MINIMUM DEPTH AT THE TOP. TOE CLEARANCE SHALL BE THE SAME WITH AND SHALL BE A MINIMUM OF 9-INCHES HIGH FROM THE FLOOR AND A MINIMUM OF 17-INCHES DEEP FROM THE FRONT OF THE LAVATORY. 43. A PROJECTION OF LAVATORY BOWL INTO THE 8-INCH CLEAR SPACE. THEREBY REDUCING THE CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN 27-INCHES AT 8-INCHES BACK FROM THE APRON, MEETS THE REQUIREMENT FOR PROVIDING KNEE CLEARANCE. 44. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 45. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST, THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. LEVER -OPERATED, PUSH -TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN. SELF -CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 46. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NOT MORE THAN 40-INCHES FROM THE FLOOR. 47. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS NOT MORE THAN 40-INCHES FROM THE FLOOR. 48. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 7-9 INCHES IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OULTET SHALL BE 15 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR, AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSORS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW. 39"MIN. z GRAB BAR W/BLOCKING 41"MAX. 12" 42"MIN. MAX. � 1-1 /4" TO 1-1/2" DIAMETER 3'-0" MAX. TOILET PAPER I = + M M "' WALL ( �' TOILET SIDE ELEVATION ACCESSIBLE SANITARY FACILITIES 1-1/2" GRAB BAR MINIMUM REQUIREMENT FOR 9 ACCESSIBLE SANITARY FACILITIES GRAB BARS: 49. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED FOR 250 LBS. PER LINEAR FEET LOAD. 50. GRAB BARS SHALL BE LOCATED ON EACH SIDE, OR ONE SIDE AND THE BACK OF THE PHYSICALLY DISABLED TOILET STALL OR COMPARTMENT AND SHALL BE SECURELY ATTACHED 33-INCHES ABOVE AND PARALLEL TO THE FLOOR. 51. GRAB BARS AT THE SIDE SHALL BEAT LEAST 42-INCHES LONG WITH THE FRONT END POSITIONED 24-INCHES IN FRONT OF THE WATER CLOSET STOOL, AND GRAB BARS AT THE BACK SHALL BE NOT LESS THAN 36-INCHES LONG. VERTICAL GRAB BAR SHALL BE 18" LONG, INSTALLED AT 39" TO 41"FROM THE REAR WALL AND 39" TO 41" ABOVE FINISH FLOOR. 52. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES TO 1-1/2 INCHES OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. 53. IF THE GRAB BAR IS MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES. 54. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. 55. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 56. EDGES SHALL HAVE MINIMUM RADIUS OF 1/8-INCH. 57. WHERE LOCKERS ARE PROVIDED, AT LEAST ONE AND NOT LESS THAN ONE PERCENT OF ALL LOCKERS SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED. A PATH OF TRAVEL NOT LESS THAN 36-INCHES IN CLEAR WIDTH SHALL BE PROVIDED TO THESE LOCKERS AND A CLEAR SPACE FOR A CIRCLE WITH DIAMETER OF 60-INCHES. 11 12 13 14 15 16 ADDITIONAL REQUIREMENTS: 65. THE CENTER OF RECEPTACLE OUTLETS SHALL BE NOT LESS THAN 15- INCHESABOVE THE FLOOR OR WORKING PLATFORMS, 66. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE 48" MAX HEIGHT FOR UNOBSTRUCTED FORWARD AND SIDE REACH. 48" MAX HEIGHT WITH 10" MAX. OBSTRUCTION AT SIDE REACH. 46" MAX HEIGHT AT 24" MAX OBSTRUCTION AT SIDE REACH 67. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR N0. 15090 IN FEDERAL STANDARD 595A. 2" MAX. FOR METAL T 4" MAX. FOR WOOD T, MINIM � MIRROR z U � � � � 1� � M N N _ z SIN � ��� 8" MIN. ADA TRAP GUARD KNEE CLEARANCE 6" MAX. TOE CLEARANCE KNEE CLEARANCES 11 68. EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY A REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON DARK BLUE BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 SQUARE INCHES IN ARE AND WHEN IN PATH OF TRAVEL, SHALL BE POSTED AT A MINIMUM OF 60-INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. AN ADDITIONAL SIGN SHALL ALSO BE POSTED AT ENTRANCE TOOFF-STREET PARKING FACILITY OR IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE. THE SIGN SHALL NOT BE LESS THAN 12-INCHES BY 18-INCHES IN SIZE WITH LETTERING NOT LESS THAN 1-INCH IN HEIGHT. REFER TO DETAIL 4/A-0.3 69. AT KITCHEN: SINKS, FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. LEVER- OPERATED, PUSH -TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN. SELF -CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS FOR AT LEAST 10 SECONDS. 14 15 A B Main Street Commons 550 Main Street Edmonds, WA 98020 smith c�. C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ E F Consultant Consultant Registration Architect Registration 6294 G REGISTERED HITECT K MITH STA E OF WASHINGTON H No. Date Issues 1 09�15�21 PERMIT 2 10�12�21 PERMIT C�RRECTI�NS I J Project Name Project Number 02016063.01 Description ADA CODE INFO K Computer File T2.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. 16 1 I 2 I 3 I 4 5 6 7 8 9 I 10 I 11 I 12 I 13 I 14 I 15 I 16 A C 1�� 1� 1� [r 1�1 J K EXIT EXIT sIONAOE REMOTE POINT POINT AT WHICH 2 PATHS OE TRAVEE BECOME AVAIEABEE IEEUMINATED EXIT PATHWAY TO BE DETERMINED BY TENANT PERMIT. z Q z z w c� Q 0 Q 1. DEFERRED SUBMITTAL: FIRE ALARM PERMIT. 2. PREMISE IDENTIFICATION: UPDATE IF REQUIRED BY FMO; 12" NUMBERS, MINIMUM 1" STROKE, CONTRASTING COLORS, INSTALLATION LOCATION TO BE DETERMINED BY FIRE MARSHAL'S OFFICE. SUITE IDENTIFICATION MINIMUM 6 INCH NUMBERS ABOVE DOOR CONTRASTING COLOR N 10 1 /2" \ 0 A B Main Street Commons 550 Main Street Edmonds, WA 98020 �� � C 603 Stewart Street suite 610 Seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration ioor Hardware to F omply with IBC 010.1.9.4. Architect Registration 6294 G H Issues and Revisions No. Date Issues 1 09�15�21 PERMIT 2 10�12�21 PERMIT C�RRECTI�NS J Project Name Project Number 02016063.01 Description EGRESS PLAN K Computer File T3.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. 1 I 2 I 3 I 4 6 r� 8 9 10 11 12 13 14 15 16 1 I 2 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 I 11 I 12 I 13 I 14 I 15 I 16 A C �� �� 1� L �il J K 1 I 2 0.905' FIRE SEPARATION FIR SEPAR T ON � FIRE SEPARATION I ' I � I�=1=#=II � � � I — I �F = II � '�� I I - � z � - I—�-------+------ © � iF = I �F II 0�, - I . . I= �F II � o / I � ,� EAT BUILDING FOOTPRINT ' � I �F II 0 0 � _� I � � I I � II ��o I A: 3, 517.5 sq ft _ * = II � n. If I $ II � �_------�---- ---- I D � =I � =II �� ► � r� � I>� = 1- # =11� LOT S I Z E :: I � � u- � III L IF I *=11� A:19,188.75sgft�—. ---------------� �� I� =I � II O I I I I I I I I I � 2 =I �IF II TWO EXISTING PARCELS BEINGS /� I -I �I�--�I � /� I J - - � � I � ___ INTO ONE PARCEL UNDER � I IIII 1 I ' ' I I , � o I � �F = II � � SEPARATE APPLICATION �� � - III ll � � �' �_� � I * =11 ' I � I _ � � Oc EL. D +87.19� II Il u � 11 II )I ,I � I 11= # =11�� 000 _ - --- — �T' C+91.05b BIKE RACKS I d = 1= # =11� 0 0 � �� ..� � I {� - u� � � uJ �00 � I f[[ A� � C I I Y ll JLL MI.L J � z z e - e- �00 t� ;FOP, MORE RPh'Q';�G, - � c 0���� � I- � � ��� � 0�� - � � �� I __- � I "'� _ ". _ENTRY r � � c RETRACTABLE CANVA ��� '- 1 I - I TRENCH DRAIN, SEE CIVIL I _ PORTAL I � � — � � AWNING, TYP OF 3 "--------_.��j C � � ` FOR MORE INFO.,iYP. JJ I _ _HANGING I � J � � � o � � � � � RETRACTABLECANV PLANTERS � � ® �� � � RETRACTABLE CANVAS +f � WNING, TYP OF 3 I ' - 1 � �� �� �� � AWNING, TYP OF 3 j \ � � Z I � � � I I 1 +I 1 �`�� �� � a 1 I I I �_ � I Il � ' ; 0.4 I I � - � � O IL� 1 � � � � � � I I I —_ ? � � �_ - 1 � PROJECT � � 1 \,� ----------------------- I o � LOCATION �%�� i ' I o I 1 0 o VAN ACCESSIBLE 80.25 sq f i I / � � � PARKING SPACE I ®o � PEF'1106.5 I1� � __-- __———_�—-�_ I o _ o�mo �o _-- _ —- -— _ _ -- 1 �. � � i I I I SEE GSHEETS � - � I I FOR h10RE INFO ❑ � I � i I = I I ��yQ j� 1/ 1 I I I I I I �� I � � � � � J � � � FIRE SEPARATION: \ � I � I � 7.694' � I `� I I I I �I � � � � � 0-hr RATING �. �I I i I T - � 10 11 12 13 14 15 I — - ` - - — - - - - - -� - - - - - — - %— - — - — - - — - - - - - - - - - - - - — - - I i I � ALLEY C.L. 1 I � 1 �_ 3 4 � 5 6 7 8 I I - - II I ' �� 84 86 88 90 92 � 92 SITE PLAN NORTH 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 I 11 I 12 I 13 I 14 I 15 16 A B Main Street Commons 550 Main Street Edmonds, WA 98020 �� � C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration F — Architect Registration 6294 G REGISTERED HITECT K MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 09�15�21 PERMIT 2 10�12�21 PERMIT C�RRECTI�NS J Project Name Project Number 02016063.01 Description SITE PLAN K Computer File T4.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ 2 3 4 5 6 7 E.3 10 12 13 14 15 16 r�� E F G H J K L R00 M FINISH SCHEDULE ALL FINISHES SPECIFIEDARE FOR PERFORMANCE. EQUAL MANUFACTURES MAY BE PROVIDED WI APPROVAL FROM ARCHITECTAND TENANT WALLS CEILING ROOM DESCRIPTION FLOOR BASE MATERIAL FINISH COLOR HT. MATERIAL FINISH COLOR 0 0 Z 0 0 0 0 O Y m J � J W J Z m Q Q � (n fn m Q J p O � O � W W � W W Z 0-' O_' Q p W � Q J U x U C7 W p U U � H H p > W J J_ J J � p J � f/J X � �� Z � p W Q � W 2 J W W � � U7 O W Z Q Z Q w � W 2 H N H Z w J W W X X F W = d J W U w J O W j X d d w Z J U O � H m W Q OU d d (� N N J N � � p O p Z d Z Z � m W W O LL W � O (7 J W J ~ CO �_ } } Cn Z Q � Z (n W � H U W } J_ J_ C:J Z W 2 Q W � � H U W m OJ LL w W p W H U Q } LL � � H J F W J Q' � J W Q 2 U � J O O U w � m U U7 LL J J W m U J W m U J_ � � Z � Q W � m fn Y Z � J _ ~ J H J Q U m Q' Q' Q J J H � J � J j� ¢ C7 J ~ Z Z_ ~ Q U" H i U Z (n Z Q� JO Q W C.7 J J Q � Q � W p W } � �= Z O� J O Q � w U } � � ¢ W m � O w H T?� x U LL rn x w Q U m � � (_ Q C.7 (_ Q C.7 W H � Q_' x LL Ova U m J �. � a. O � � � X � J Q W �a �a ¢ F O m p U � � O w � J � � o �t~q O O qa � Z w a O O w � d w �a x Z } U o O ¢ ? � � Ha � ROOM NAME O � x U � x x � co O w LL !q� w � X� `� � X X ¢ ¢ � ¢ C7 O Q U U O CO (O (O (O (O fn � u� � fn U a � N N � U J Z tJ fn � (V fn (V fn W N J LL � a J Z a 101 CUSTOMER AREA • • • • • • 102 HALLWAY • • • • • • 103 SERVICE AREA • • • • • • 104 DISHWASH AREA • • • • • • 105 KITCHEN AREA • • • • • • 109 TOILET • • • • • • NOTE: QUARRY TILE FLOOR UNDER EQUIPMENT HAS TO BE SMOOTH. 1O QUARRY TILE BASE SHALL BE 6" Wl3/B"COVE RADIUS BY DAL -TILE O3 CERAMIC TILE BASE SHALL BE 6" WI3I8"COVE. O CLASS A PER ASTM E-84 O CLASS "A" FIRE -RATED CEILING PANEL. O PAINT FINISH IN THE RESTROOM, KITCHEN AND DRY F000 STORAGE WILL BESEMI-GLOSS PAINT FINISH DOOR SCHEDULE NO. DESCRIPTION MFG SIZE FRAME THK CORE TYPE FACE/EDGE HARDWARE REMARKS 1O (E) STOREFRONT DOOR EXISTING 3'-0" X 7'-0" ALUM 1-3/4" gLUM D2 EXISTING RE -KEY SELF-CLOSINGI BY GC O2 NOT USED O3 (N) RESTROOM DOOR NEW 3'-0" X 7'-0" WOOD � 3/4" SC WOOD D6 SELF -CLOSING, LEVER TYPE O4 NOT USED O5 NOT USED O6 NOT USED O7 (E) REAR DOOR H. METAL 3'-0" X 7'-0" H. METAL 1 3/4" H. METAL D6 SELF -CLOSING, LEVER TYPE 10" KICK PLATE; PEEP HOLE AND DEADBOLT WALL SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE N0. DESCRIPTION W1 EXISTING WALL TO REMAIN t.l NOT USED EXISTING STOREFRONT SYSTEM TO MATCH EXISTING, GLAZING TO BE FIXED W/TEMPERED GLASS W3 3-5/8" 20GA. METAL STUD WALL W/ 5/" TYPE "X" GYP. BOARD ONE SIDE (WATER RESISTANT) WHITE SMOOTH FINISH FRP T010'-0" W4 3-5/8" 20GA. METAL STUD LOW WALL W/ %" TYPE "X" GYP. BOARD ON BOTH SIDES BLACK FRP (WP-1) ON INSIDE/WOOD VENEER (MF-1) ON OUTSIDE W5 4" 20GA. METAL STUD WALL W/ %" TYPE "X" GYP. BOARD BOTH SIDES (WATER RESISTANT ON RESTROOM SIDE) W6 3-5/8" 20GA. METAL STUD WALL FUR -OUT W/ %e' TYPE "X" GYP. BOARD ON INTERIOR SIDE ONLY (WATER RESISTANT ON RESTROOM SIDE) W7 2-5/8" 20GA. METAL STUD WALL FUR -OUT W/ %" TYPE "X" GYP. BOARD ON INTERIOR SIDE ONLY (SEE ARCHITECTURAL DETAILS &ELEVATIONS) 6X METAL STUD W/ (2) 5/e' TYPE "X" GYP. BOARD ON BOTH SIDES UL DESIGN U419 WALL PAN E L SC H E D U L E INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER DESCRIPTION MFG # COLOR FINISH REMARK WP-1 CRANE COMPOSITES INC. F.R.P. THICKNESS:.075 (4X10) GLASBORD SMOOTH WHITE FURNISHED BY INSTALLED BY G.C. WP-2 CUSTOM S.S. PANEL (22 GA) STRAIGHT BRUSHED FINISH FURNISHED BY INSTALLED BY G.C. GENERAL NOTES 1. CONSIDERATION WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDINGS OF THE AMOUNT OF WORK TO BE PERFORMED. TENDER OF PROPOSAL SHALL CONVEY FULL AGREEMENT TO THE ITEMS AND CONDITIONS INDICATED ON THE DRAWINGS. SHOULD THE CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENT OR BE IN DOUBT AS TO THE INTENT THEREOF, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT AND/OR THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING HIS PROPOSAL FOR WORK. 2. T. G. C. SHALL FIELD VERIFY THE EXACT EXISTING SPACE CONDITIONS, DIMENSIONS AND COLUMN SPACING PRIOR TO CONSTRUCTION AND INFORM ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND BETWEEN DRAWINGS AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BEAT T. G. C.'S EXPENSE. 3. ALL COLUMNS IN THE LEASE SPACE TO HAVE AT LEAST 1-HOUR FIRE SURROUND OR FIRE RATING AS REQUIRED BY LOCAL CODE (5/8" TYPE'X' GYP. BD. ON METAL STUD FRAMING FROM FLOOR TO DECK AND SEALED TIGHT. HEALTH DEPT. NOTES 1. ALL EQUIPMENT SHALL MEET NATIONAL SANITATION FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS OR IT'S EQUIVALENT. 2. LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD STORAGE AND UTENSIL WASHING AREAS ARE TO BE PROTECTED AGAINST BREAKAGE THROUGH THE USE OF PLASTIC SHIELDS, PLASTIC SLEEVES, SHATTER PROOF BULBS AND/OR OTHER APPROVED DEVICES. 3. PROVIDE PERMANENTLY MOUNTED SINGLE SERVICE SOAP AND TOWEL DISPENSERS AT ALL HAND WASH BASINS. 4. SEAL ALL CRACKS AND CREVICES IN COUNTERS, CABINETS, AROUND METAL FLASHING, SINK BACK SPLASHES AND AROUND PIPES AND CONDUITS WITH ANON -HARDENING SILICONE SEALANT. 5. QUARRY TILE TO BE "DAL TILE". 6. ALL WALL &DRYWALL CEILING ARE TO BE PAINTED W/ SAME PAINT AS INDICATED ON THE FINISH SCHEDULE. 7. ALL CABINETS SHALL BE LAMINATED INSIDE AND OUT. 8. CEILING IN FOOD PREPARATION/ RESTROOM TO BE SMOOTH, NON -ABSORBENT, DURABLE, LIGHT IN COLOR AND EASILY CLEANABLE. 9. ALL OPENINGS LEADING TO OUTER AREAS MUST BE TIGHT FITTING WHEREBY NO LIGHT SHALL BE SEEN WHEN DOORS ARE CLOSED, TO PREVENT ENTRANCE OF PESTS. G.C. NOTES 1. G.C. TO FIELD VERIFY EXISTING SITE CONDITION PRIOR TO BIDDING THE PROJECT. 2. G.C. TO PATCH, REPAIR &REFURBISH THE EXISTING WALL, FLOOR &CEILING FINISH AT THE KITCHEN, WASHING &STORAGE AREA AS NEEDED OR OWNER'S INSTRUCTION. FIRE NOTES 1. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. 2. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. EXIT LIGHTING AND SIGNS: MINIMUM 6" X 3/4" LETTERS ON CONTRASTING BACKGROUND. 4. ANY DECORATION USED SHALL BE NON-COMBUSTIBLE OR FLAME -PROOFED IN AN APPROVED MANNER. 5. THE INSTALLATION OR OPERATION OF SPECIAL FIRE EXTINGUISHER SYSTEM MUST BE CHECKED AND APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION. 6. PROVIDE OUTSIDE GAS SHUT-OFF VALVE CONSPICUOUSLY MARKED. 7. DEFERRED SUBMITTAL: 7.1. FIRE SPRINKLER DRAWINGS AND SPECIFICATIONS TO BE SUBMITTED BY A LICENSED SPRINKLER COMPANY TO THE FIRE MARSHALL, FOR REVIEW AND APPROVAL, PRIOR TO SYSTEM INSTALLATION/ ALTERATION 7.2. FIRE ALARM PLANS AND SPECIFICATIONS TO BE SUBMITTED BY A LICENSED FIRE ALARM CONTRACTOR TO THE FIRE MARSHALL, FOR REVIEW AND APPROVAL, PRIOR TO SYSTEM INSTALLATION/ ALTERATION 2 3 4 5 TYPE II HOOD MECHANICAL PERMIT IS REQUIRED AND WILL BE APPLIED FOR UNDER A SEPARATE PERMIT, SHAFT ROUTE AND TERMINATION BY LANDLORD UNDER SHELL PERMIT WALL LEGEND EXISTING WALL SERVICE COUNTER DIE WALL BY G.C. WALK-IN BOX PANEL NEW FULL HEIGHT PARTITION BY G.C. NEW FULL HEIGHT PARTITION BY G.C. KEYNOTES N0. DESCRIPTION 0 PROVIDE SIGN "THIS DOOR TO REMAIN UNLOCKED WHILE THE BUILDING IS OCCUPIED". 0 PROVIDE SIGN OF INTERNATIONAL SYMBOL ACCESSIBILI IBC 1009.8-1009.11 SEE DET. 6 G-1.2. TACTILE EXIT SIGN SEE DET. 6 G-1.2. ❑4 CAPACITY SIGN PER IBC 1004.3 �s STAINLESS STEEL COUNTER AT 36" HIGH A.F.F. �s TYPE II EXHAUST HOOD. ❑7 ACCESSIBLE RESTROOM SIGNAGE, SEE DETAIL 1/-2.0 �B NOT USED ❑9 (E) REAR EXIT �o MENUBOARD ABOVE, BY OTHERS. 11 ELECTRICAL PANEL NOT USED COUNTER � 36'° HIGH A.F.F. (E) COLUMN TO REMAIN (E) STOREFRONT GLAZING. FIXED W/ TEMPERED GLASS AND NON-OPENABLE. (E) STOREFRONT DOOR 12 13 14 ,5 �s 17 NEW QUARTZ COUNTER, CONFIRM WffH OWNER ie NOT USED 19 NOT USED BUILDING NOTE: ALL GLAZING TO BE TEMPERED GLASS. NOTE: 1. PANEL DIVIDERS AT WP3 2. INSIDE CORNER AT WP3 TO WP2 3. FLASHING AT TOP OF BASE WP3 4. WP2 PIECE AT LENGTH OF WALL 5. ALL OTHER STAINLESS STEEL BY G.C. NOTE: THE FOLLOWING STAINLESS STEEL PROVIDED BY G.C.-INSTALLED BY G.C.: (� 18 GA. STAINLESS STEEL G��� � CORNER GUARD (� 18 GA. STAINLESS STEEL � � CORNER GUARD/FRAME -ALL G� AROUND PERIMETER OF OPENING - FRAME TO BE WELDED WITH MITERED CORNERS TO FORM SINGLE UNIT. (L� 18 GA. STAINLESS STEEL �G� WALL CAP *ALL INTERIOR DIMENSIONS ARE FINISHED TO FINISHED NOTE: *G.C. TO INSTALL MIN 3-1/2" NON-COMBUSTIBLE MINERAL FIBERGLASS BATTS SOUND INSULATION AT ALL RESTROOM PARTITIONS AND CEILINGS. DOOR SCHEDULE G.C. TO PROVIDE LEVER TYPE HARDWARE PANIC HARDWARE SEE DET. DOOR SIGN SEE 1 /G 1.2 DET. 1 /G 1.2 ���/ 4pa 0 I _ i� � �// � i� i� F.FLR. D2 (EXISTING STOREFRONT DOOR) 6 D5 S.S. KICK PLATE 7 LEVER TYPE HARDWARE 0 i� D6 S.S. KICK PLATE 8 4 8 8 1 FLOOR PLAN 10 12 13 14 7 8 15 NORTH 16 Na re � IBC /_� B Main Street Commons 550 Main Street Edmonds, WA 98020 �� C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ D Consultant E t0 Consultant Registration F Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CORRECTIONS J Project Name Project Number 02016063.01 Description FLOOR PLAN K Computer File A-1.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ Main Street Commons 550 Main Street Edmonds, WA 98020 ���► 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Architect Registration 6294 REGISTERED HITECT t IKE MITH STA E OF WASHINGTON Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CORRECTIONS Project Name Project Number 02016063.01 Description DIMENSION PLAN Computer File A-1.1.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ 6 7 8 9 10 11 12 13 14 15 16 n C ■ �J E G H J K L 2 � 3 4 5 WALL PANEL SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER DESCRIPTION MFG# COLOR FINISH REMARK WP-1 CRANE COMPOSITES INC. F.R.P. THICKNESS:.075 (4X10) GLASBORD SMOOTH WHITE FURNISHED BY INSTALLED BY G.C. WP-2 CUSTOM S.S. PANEL (22 GA) STRAIGHT BRUSHED FINISH FURNISHED BY INSTALLED BY G.C. WALL FINISH SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER DESCRIPTION MFG # COLOR FINISH REMARK SPECIAL SURFACE SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER PRODUCT MFG# STAIN/COLOR FINISH REMARKS MF-1 FORMICA 5264 -Gracious Sakura FORMICA MATTE MATTE FURNISHED BY INSTALLED BY G.C. QT-1 QUARTZ Bianco Verona polished PENTAL - POLISHED FURNISHED BY INSTALLED BY G.C. PL-1 FORMICA 0909 -BLACK FORMICA BLACK MATTE FURNISHED BY INSTALLED BY G.C. INTERIOR PAINT SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER MFG # COLOR FINISH REMARK PT-1 SHERWIN-WILLIAMS TBD TBD EGGSHELL LOW SHEEN PAINT PT-2 SHERWIN-WILLIAMS TBD TBD EGGSHELL LOW SHEEN PAINT PT-3 SHERWIN-WILLIAMS TBD TBD EGGSHELLISEMI-GLOSS LOW SHEEN PAINT PT-4 SHERWIN-WILLIAMS TBD TBD FLAT LOW SHEEN PAINT LOW SHEEN PAINT TRANSITION/ TRIM/ BASE SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO MANUFACTURER MFG # COLOR FINISH REMARK TR-1 PEMCO 168 DK BRONZE DARK BRONZE HALF THRESHOLD FURNISHED BY INSTALLED BY G.C. TR-2 SCHLUTER DILEX-AHKA BRUSHED NICKEL BRUSHED ANNODIZED ALUMINUM 3/8" RADIUS COVE FURNISHED BY INSTALLED BY G.C. TR-3 SCHLUTER JOLLY BRUSHED NICKEL BRUSHED ANNODIZED ALUMINUM EDGE TRIM FURNISHED BY INSTALLED BY G.C. ST-1 CUSTOM COLD ROLLED STEEL CUSTOM 1/8"THICK COLD ROLLED CLEAR FINISH @ CUSTOMERI SALES AREA 6" BASE FURNISHED BY INSTALLED BY G.C. RB-1 ROPPE ROPPE #193 BLACK BROWN 6"VINYL BASE FURNISHED BY INSTALLED BY G.C. TILE SCHEDULE N0. MANUFACTURER DESCRIPTION MFG # COLOR FINISH JOINT GROUT REMARKS QT-1 DALTILE 6"X6"QUARRY TILE PURITAN GRAY ABRASIVE 3/16" G-94 COOLER, SERVICE FLOOR FURNISHED BY INSTALLED BY G.C. QT-2 DALTILE 6" X 12"QUARRY TILE COVE BASE 1" X 6"QUARRY TILE CORNER PURITAN GRAY PLAIN 3116" G-95 KITCHEN, SERVICE BASE FURNISHED BY INSTALLED BY G.C. T-1 Natural Surfaces PORCELAIN TILE TBD MATTE 3/32" LVL-1 SHEET VINYL CORLON ARMSTRONG GRANITE GRAY #88701 - - - W/6 "TURNED UP(INTERGRAL) BASE FURNISHED BY INSTALLED BY G.C. CONC EXISTNG CONCRETE DIAMOND GRIND AND SEAL GC EXISTING SMOOTH - - FURNISHED BY INSTALLED BY G.C. T_2 WHITE SUBWAY TILE 4"X12"CERAMIC TILE ARIZONA TILE WHITE GLOSSY GLOSSY 1/16" G-93 FURNISHED BY INSTALLED BY G.C. GROUT SCHEDULE N0. MANUFACTURER DESCRIPTION MFG # COLOR FINISH JOINT REMARKS G-93 POLYBLEND CUSTOM BUILDING PRODUCTS https://www.custombu ild ingprod ucts. coml POLYBLEND NON -SANDED GROUT #381 BRIGHT WHITE NON -SANDED 1/16" WALL TILES/ FLOOR TILES G-94 POLYBLEND CUSTOM BUILDING PRODUCTS https://www.custombuildingproducts.coml POLYBLEND NON -SANDED GROUT #540 TRUFFLE SANDED 3/16" KITCHEN AND SERVICE AREA FLOOR. 100% SOLIDS INDUSTRIAL GRADE EPDXY GROUT SEE PLAN G-95 CEG-EPDXY GROUT CUSTOM BUILDING PRODUCTS https://www.custombu ild ingprod ucts. coml POLYBLEND NON -SANDED GROUT #165 DELOREAN GRAY 1/8" FLOOR TILES 3 �4) 5 6 1 FLOOR FINISH PLAN 7 8 FLOOR FINISH NOTES: TILE LEGEND 8 MAINTAIN A SLOPE OF 1/8" PER FOOT TO FLOOR DRAIN. (TYPICAL) O FLOOR SINK MUST BE READILY ACCESSIBLE FOR INSPECTION & O TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD CLEANING, AND SHALL BE DESIGNED TO PREVENT THE FLOW OF NON —ABSORBENT SURFACE SUCH AS PORTLAND CEMENT, CERAMIC A SEWAGE BACK—UP FROM GOING UNDER THE INSTALLED TILE OR OTHER APPROVED MATERIAL THAT EXTENDS UPWARD ONTO O2 A MAXIMUM OF 1 2—INCH OFFSET AT ALL THRESHOLDS AND AT ANY CABINET WORK. CUT AND LEAVE FRONT TOE —KICK SPACE OPEN THE WALL AT LEAST 4" (1210.1) CHANGE OF FLOORING MATERIAL. OFFSETS GREATER THAN AT THE FLOOR SINK LOCATION AND BOX AROUND THE FLOOR 1/4—INCH REQUIRE A MAXIMUM BEVELED SLOPE OF 1 UNIT VERTICAL TO 2 UNITS HORIZONTAL, EXCEPT THAT LEVEL CHANGES SINK ON THREE SIDES WITH BASE TILE. O WALLS WITHIN 2 FEET OF THE FRONT SIDES OF URINALS AND WATER ���',' T-1 CONC LVL-1 � INS TE-1 NOT EXCEEDING 1 /4—INCH MAY BE VERTICAL. (2013 CBC SEC. O FLOOR COEFFICIENT OF FRICTION MINIMUM 0.6 PER ASTM C1028 OR EQUIVALENT. CLOSETS SHALL HAVE A SMOOTH NON —ABSORBENT SURFACE OF PORTLAND CEMENT, CONCRETE, CERAMIC TILE OR OTHER SMOOTH, O % j�� 1 1 B-403.4) HARD NON —ABSORBENT SURFACE TO A HEIGHT OF 4 FEET, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. (1210.2) OVER MRGB OR AN EQUIVALENT APPROVED SUBSTRATE. 1 I 2 .� 4 5 I 6 7 7 10 12 I 13 14 15 16 /_� B Main Street Commons 550 Main Street Edmonds, WA 98020 ���► C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration F Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CORRECTIONS I J Project Name Project Number 02016063.01 Description FLOOR FINISH PLAN K Computer File A-1.3.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ 1 I 2 3 4 5 6 7 E�3 9 10 11 12 13 14 15 16 C ■ �J E G H J K L 1 I 2 LIGHTING FIXTURE SCHEDULE PROVIDED FOR INFORMATION ONLY. PER ELECTRICAL DRAWING VERIFY AND INSTALL INTERIOR LIGHTING ITEM (ALL LIGHTS SHALL BE 2700K U.O.N.) ITEM SYMBOL DESCRIPTION QTY. MFR. &CAT. NO. REMARK L1 L1 2'x4' LED SURFACE TROFFER LIGHT FIXTURE ORACLE LIGHTING, OT-LED SERIES 2700 LUMENS KITCHEN CEILING LIGHTS �;:��,; https://www.homedepot.com/plLithonia-Lighting-MNLK-L48-830-M4- FURNISHED AND INSTALLED BY G.C. __�;�� 2'x4' LED RELOCATED FROM TOTEM LOCATION Linkable-4-tt-White-LED-Strip-Light-MNLK-L48-830-M4/205570117 L1 TROFFER LIGHT FIXTURE EXISTNIG LIGHTS - RELAMP WITH 2700K EXISTING KITCHEN CEILING LIGHTS ® (E) � RE -LAMP BY G.C. L4 ® UNIVERSAL MOUNT EXIT SIGN, LED LIGHTED, 120V WITH EXIT SIGN L4 BATTERY PACK, 2 FACE, GREEN LETTER z MAXILUME LIGHTING, ELX-603 FURNISHED AND INSTALLED BY G.C. LIGHTS SUPPLIED &PRE -WIRED BY HOOD VENDOR. L6A HOOD LIGHT � FURNISHED &INSTALLED BY EQUIPMENT ELECTRIC CONTRACTOR TO CONNECT MAIN WIRES L6A x SUPPLIER TO SHUNT TRIP BREAKER AND HOOD CONTROL � z �_ � PANEL 8 L6B � WALK-IN COOLER FLUORESCENT LIGHT, 120 V 48" KASON FURNISHED BY WIC VENDOR o FIXTURE: # 18180F00048 L66 0 0 COMMERCIAL PATIO STRING LIGHTS W/LED BULB w 1W G40 E17 BULB 2700K APPROX. 150 FT FURNISHED AND INSTALLED BY G.C. A = J � � ® 6" DIA. DOWN LIGHT, RECESSED IN CEILING ELITE LIGHTING, B6-LED SERIES, 2000 LUMENS FURNISHED AND INSTALLED BY G.C. B PROVIDE SHATTER PROOF COVERS OR BULB � � w w � w O LED PENDANT LIGHT, COLOR: AGB BARN LIGHT ELECTRIC,The Cordoba Pendant CONTACT: WWW.BARNELECTRIC.COM FURNISHED AND INSTALLED BY G.C. �C 10'-0" C LL w /lighting/barn-lights/ceiling-pendants/cord-pendantlthe-Cordoba-pendant P1413483 PROGRESS LIGHTING CYLINDER WHITE 29W LED FURNISHED AND INSTALLED BY G.C. D PROVIDED BY TENANT FURNISHED BY OWNER AND INSTALLED BY G.C. E 0 LITHONIA LIGHTING, ELA SERIES, PAR 36, 12W/ 12V FURNISHED AND INSTALLED BY G.C. EXTERIOR EMERGENCY LIGHTING INCANDESCENT, SINGLE HEAD, COLOR: BLACK M UL94V-0/ UL 1598 WAC LIGHTING OCULUX L-TRACK 6" TALL 2700K LED TRACK TRACK AND TRACK LIGHTING HEAD WITH ADJUSTABLE BEAM ANGLE Model: L-7011-50-930-BK FURNISHED AND INSTALLED BY G.C. LIGHT:HIGH OUTPUT 3 STEP MACADAM, ELLIPSE COB, 90+ CRI K RATED LIFE OF 50,000 HOURS AT L70-DIMMABLE JUNO COMPATIBLE TRACK NIGHT LIGHTING REQUIREMENTS: "NL" DESIGNATION INDICATED NIGHT LIGHT ON UNSWITCED CIRCUIT. LONE NL BY SERVICE COUNTER, POS I CASHIER 2.ONE NL BY EACH EXIT DOORS IN DINNING ROOM & BACK OF HOUSE 3.ONE NL BY MANAGER STATION CEILING SCHEDULE NO MANUFACTURER DESCRIPTION MATERIAL FINISH C1 OPEN CEILING OPEN CEILING PAINT FLAT BLACK C2 USG 2' X 4' SUSPENDED T-BAR GRID EXISTING GRID TO REMAIN REPLACE TILES ONLY CEILING SYSTEM SYSTEM, ICC-ESR 1222 (CLASS A) Ceilings - ULTIMA Lay -In and Tegular -1894 WHITE C3 GOLD BOND MONOLITHIC CEILING ON METAL 5/8" TYPE-X GYPSUM BOARD PAINTED FINISH FRAMING SMOOTH AND WASHABLE, COLOR: AS SCHEDULED NOTE: ALL LIGHTING TO BE ON DIMMERS 3 4 5 6 7 7 1 REFLECTED CEILING PLAN - SCALE: 114"=1'-0" 10 12 13 14 7 8 15 16 ��1 B Main Street Commons 550 Main Street Edmonds, WA 98020 �� C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration F Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CCRRECTICNS I J Project Name Project Numbe02016063.01 Description REFLECTED CEILING PLAN K Computer FileA-1.4.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ Main Street Commons 550 Main Street Edmonds, WA 98020 ���► 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant Consultant Registration Architect Registration 6294 REGISTERED HITECT t IKE MITH STA E OF WASHINGTON Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CORRECTIONS Project Name Project Numbe02016063.01 Description TOILET PLAN/ELEVATIONS Computer FileA2.0.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of s as, designs, arrangements or plan all be use or disclosed to any perso orporation for any ose whats ver without the written permission of sm' co. Ilc. A-2.0 2 3 4 5 6 7 8 9 12 13 14 15 16 C E G H J K L 314 "RELIEF I B.O. CEILING EXISTING FIN. FLR. LINE 0'-0" 10 g" PLYWOOD BACKING ON TILE WALL B.O. CEILING EXISTING FIN. FLR. LINE 0'-0" ICC A117.1 - 2009 PER 306 KNEE AND TOE CLEARANCE QT-1 02 ��� QT-1 A-3.0 }� � Jr; TYP� ~ f I HANDLE t� AR EST L S T Ch �' T F / I j M o c�-> 1 BACK COUNTER ELEVATIONS 2 TYPICAL FRONT COUNTER ELEVATION SCALE:1/2"=1'-0" SCALE:1/2"=1'-0" STRAP TO WALL STRUCTURE W/ 2 " WIDE 16 GA STEEL BAND DRIP PAN WITH INDIRECT DRAIN TO FLOOR DRAIN BELOW NOTES: 1. ALL PIPING SHALL HAVE A MINIMUM OF 1" OF INSULATION. 2. PROVIDE A TIME SWITCH OR OTHER CONTROL DEVICE THAT CAN BESET TO SWITCH OFF THE USAGE TEMPERATURE MAINTENANCE SYSTEM DURING EXTENDED PERIODS WHEN HOT WATER IS NOT REQUIRED. 4 WATER HEATER SEISMIC RESTRAINT 6 TYPICAL REAR COUNTER ELEVATION SCALE:1/2"=1'-0" SCALE:1/2"=1'-0" PT3 PT3 PT3 M�E(,HAhHCA�l100D - - � � — GC TO PROVIDE PLYWD BACKING �— — -- ----� e WP-1 i � ---� GC TO PROVIDE PLYWD BACKING � � ---- -- I� III WP-1 - — — — . 0 0 0 0 o O �� - 0 0 S/S WALL WP_2 :t i i 2 CONV OVEN 3 KITCHEN ELEVATION 3 HEARTH OVEN 4 5 QT-2 6 3 SINK W/SHELVES 7 DISHWASHER QT-2 MOP SINK CEILING HEIGHT �, � KITCHEN AREA v EXISTING b b o � h � FIN. FLR. LINE ��` 0'-0" 10 LOCKERS ,, B.O. CEILING {ISTING LOCKERS 5 HALLWAY ELEVATION 12 13 1" MDF BASE - PAI 14 15 CEILING HEIGHT ® KITCHEN AREA EXISTING FIN. FLR. LINE 0'-0" 16 I�1 B Main Street Commons 550 Main Street Edmonds, WA 98020 �� C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration F Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CCRRECTICNS I J Project Name Project Numbe02016063.01 Description ELEVATIONS K Computer FileA2.1.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ FJ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 n C E G H J K L 1 I 2 I 3 I 4 MIN. 2-#8 METAL SCREWS � 362S125-33 w^ METAL STUD WALL W/ \ \ DIAGONAL BRACING � � 5/8" TYP "X" GYP. BD. � � � 362S125-33 @ 16" � SPACED @ 48" O.C. ON BOTH SIDES 6 l STAGGERED IF USED � O.C. (WH. OCCURS) - � � (N) 'L' 6X4X12 GA. X3" CO�JNTER TOP QT-1 � \ � � WIDE ANGLE W/ (3)-�10 MITRE CORNERS, TYP. � Z o m TEK SCREW TO HOOD POS COUNTER BASE CABINET —MDF � � AND (3)-�10 TEK SCREWS TO WALL AT (2) ADJ SHELVES -PAINT GYP. BD. CEILING l J � SUSPENDED EACH END OF THE HOOD WHERE OCCURS ACOUSTICAL CEILING & @ 4'0" O.C. TYP. LARR #2404 WH. OCCURS EXHAUST HOOD 3" MDF PANELS OVER 1/2" a PLYWD. -PAINT O PROVIDE MTL STOP & CONT MTL STUD FRAMING, Z ° ° SEALANT @GYP. BD. CEILING EXTEND 6" ABOVE � 3 5/8" 20 GA. METAL STUDS 5/8" TYPE "X" GYP. CEILING HEIGHT o CONT. TRACK ° � @ 16" O.C. ICC-ESR 4943P BD. EA SIDE 3-5/8" X 25 GA. J W/.180" DIA.X2" o ° ° 1/2" GREEN GYP. BD. W/ BLACK "HILTI" METAL STUDS @ 16" LON. POWER I FRP LINING POWER -DRIVEN PINS O.C. (U.N.O.) "CEMCO" w N DRIVEN SHOT PINS ° ° 1/2" CEMENT BD. 24" O.C. MAX. TYP. U.N.O. METAL STUDS/VIPER @ 16" O.C. ICC-ES ESR-1663 TACK WELD (ICC ESR-1799) LARR #25646 STUDS O � BASE &FLOOR PER ICC-ESR 2620 3" MIN. AIR SPACE FINISH SCHEDULE FLOOR FINISH AS SCHEDULED BASE AS SCHEDULED N r 6" MDF BASE -PAINT `� a �� FINISH FLOOR a a 4 TYPICAL HOOD AT WALL CONNECTION 2 TYPICAL DIE WALL BY GC 3 TYPICAL WALL DETAIL - SCALE:1/2"=1'-0" - SCALE:1/2"=1'-0" - SCALE:1/2"=1'-0" COLD STORAGE ROOM RAISED CURB (IF ANY) 4" REDHEAD TO B.O. FLOOR @ 12" O.C. -- ------ --------- TYP. N � • a• '• .. r• EXISTING FLOOR •e .. •�"•. • , •• •• ••• . <: •a •' •.• •• TO REMAIN, TYP. •� • • . :. FINISHED FLOOR .. •�••°� •° • VERIFY WITH FLOOR SINK 362T125-33 CONT. LOCAL CODE TOP TRACK W/ METAL STUD (1)-�10 TEK SCREW EXISTING PT SLAB TO REMAIN "P" TRAP OA SLIP TRACK PERPENDICULAR TO JOIST ON EA. SIDE OF TRACK/BRACE AT EA. X-RAY PRIOR TO CORING STUD @ 24" O.C. RAISED CURB (IF ANY) R � EXISTING FLOOR TO REMAIN, TYP. � 362T125-33 CONT. TOP � TRACK W/ (1)-�10 TEK � � 4" REDHEAD TO B.O. SCREW ON EA. SIDE OF 00 00 c � � � � �'-'-' o � � FLOOR @ 12" O.C. METAL TRACK/BRACE AT EA. STUD � o � TYP. STUD @ 24" O.C. p � /�oA 77 O SLIP TRACK PARALLEL TO JOIST F.F. 4 TYPICAL FLOOR SINK SECTION 6 TYPICAL WALL CONNECTION - SCALE:1/2"=1'-0" - SCALE:1/2"=1'-0" 2"X6" BLOCKING ATTACHED TO (E) TRUSS W/ 'U' SS WALL PANEL HANGERS SEE DETAIL 10/- SILICONE JOINT SEALANT 2x4 WOOD STUDS AT JAMB 5-3/4" X 2 METAL 8c HEAD W/ ANCHOR FRAME FOR REAR HOOD 2"X2"X1/4" SS FLASHING BEHIND STRAP MOUNTING ®`` ANGLE SS WALL PANEL AND � 3/8"D THREADED ON TOP OF Q.T. BASE __ ����` ® ROD HANGERS, � TYP. QUARRY TILE BASE WOOD DOOR SLOPE FLOOR TO PROVIDE POSITIVE DRAINAGE - 1/2" @ WALL TO 0" @ 24" AWAY, INSTALL WP MEMBRANE 8" UP ON WALL AND FLOOR D _ ° p D �° p D D PROVIDE MApCHINE ° ° p. D p � p o ° ° � 4 P GYPSUM BOARD BOLT NUT CX. D ° . p ° 6 � D �. WASHER BY HOOD SUPPLIER ° p � ° D H00 D D ° p WELD 7 TYPICAL DOOR JAMB 8 TYPICAL HOOD SUPPORT 9 TYPICAL WALK-IN COOLER BASE - SCALE:1/2"=1'-0" - SCALE:1/2"=1'-0" - SCALE:1/2"=1'-0" 5 6 7 7 10 12 13 14 15 16 A B Main Street Commons 550 Main Street Edmonds, WA 98020 �� C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration F Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CCRRECTICNS I J Project Name Project Numbe02016063.01 Description DETAILS K Computer FileA3.0.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ I+a K� 4 5 6 7 9 10 12 13 14 16 n C ■ �J E G H J K L EQUIPMENT SCHEDULE PLUMBING ELECTRICAL EQUIPMENT ITEM REMARKS GAS WASTE HOT WATER COLD WATER � U w o U LOAD = o m � Z m } � MODEL NO. MANUFACTURER DESCRIPTION QTY. rrEM SIZE R.I.H. MBTU TYPE SIZE R.I.H. SIZE R.I.H. SIZE AMPS WATTS H.P TEA /COFFEE AREA 1 1 1 2 30A 220 G.C. 0 GB-5 LA MARZOCCO 2-GROUP ESPRESSO 1 2 3 G.C. 0 - - 1 3 4 1 4 5 1 5 6 G.C. 0 WS5A MICROS POS 2 6 7 G.C. 0 1 7 8 G.C. 0 3 8 9 G.C. 0 - - TRASH CANS 1 9 10 G.C. 0 1 10 11 G.C. 0 2 11 12 G.C. 0 72X30 SS TABLE 3 12 13 13 14 G.C. 0 2 14 15 G.C. 0 1 15 16 G.C. 0 1 16 17 G.C. 0 2 17 17 G.C. 0 2 17A 18 2.7A 1/4 115 G.C. 0 Tuc-72-Hc TRUE UNDERCOUNTER REFRIG 1 18 19 MAX. 6.7 GPM, CAPACITY 36,000 GAL. 10-125 PSI G.C. 0 EV9329-54 EVERPURE WATER FILTER SYSTEM 1 19 20 11'-6" X 2'-3" G.C. 0 - CUSTOM 3 COMPARTMENT SINK 1 20 20P G.C. 0 52922, 11366, 61549, 54429 FISHER FAUCET &SPOUT 1 20P 21 W/ MIN. 6" SPLASH GUARD ON BOTH SIDES G.C. 0 HS-1615SS GSW WALL MOUNT HAND SINK 2 21 21 P G.C. 0 62839 & 54453 FISHER FAUCET &SPOUT 2 21 P 22 G.C. 0 BK-DIBHL-2218 BK DROPIN ICE BIN 1 22 PROVIDE 6'-0" MIN. S.S. G.C. 0 BK-DIS-1515 BK DROP-N SINK 1 22A SPLASH GUARD ON BOTH SIDES G.C. 0 1 31 9-OP-20 ADVANCE TABCO MOP SINK 1 31 31P 19798 FISHER FAUCET 1 31P 36 G.C. 0 M341822082 XG50T06PV42U0 WATER HEATER 2 36 39 13.5A 1 115 G.C. 0 NE0140/190 MANITOWOC ICE MAKER W/ ICE BIN-UNDERCOUNTER 1 39 40 G.C. 0 ELS-5DR GSW LOCKERS 1 40 41 G.C. 0 600ST3072RT REGENCY 1 COMPARTMENT SINK 1 41 41 P G.C. 0 61549 & 54410 FISHER FAUCET &SPOUT 1 41 P G.C. 0 1 51 52B 48"X14" G.C. 0 WS-W1424 GSW S.S. WALL MOUNT SHELF 1 52B 52C 14"X36" G.C. 0 WS-W148 GSW S.S. WALL MOUNT SHELF -LENGTH BY OWNER - 52C 58 G.C. G.C. CAPTIVE-AIRE TYPE II EXHAUST HOOD 1 58 58A G.C. G.C. CAPTIVE-AIRE SHUT-OFF SWITCH 1 58A 58B G.C. G.C. CAPTIVE-AIRE OVEN TIMER 1 58B 59 G.C. 0 - 1 59 60 11A 1 120 G.C. 0 COFFEE GRINDER 1 60 60A 1 115 G.C. 0 1 60A 61 G.C. G.C. - PARRY PIE CABINET -ELECTRIC HEATE 61 62 G.C. G.C. 62 63 G.C. G.C. GB3 SCHIER 75 GAL GREASE INTERCEPTOR 1 63 64 G.C. 0 - 64 65 G.C. GC - - 1 65 66 G.C. 0 CUSTOM AIRCOOLER WALKIN FREEZER 1 66 67 G.C. 0 CUSTOM AIRCOOLER WALKIN COOLER 1 67 68 - 1 68 - - 1 68B 6g 4.5A 1 115 G.C. 0 CAROUSEL II SHARP MICROWAVE 1 69 70 G.C. 0 1 70 71 G.C. 0 1 71 72 G.C. 0 1 72 73 G.C. 0 5 73 74 G.C. 0 1 74 75 G.C. G.C. 1 75 76 G.C. O _ WAKING FOOD PROCESSOR 1 76 77 16A 1 115 G.C. 0 G18507T Autochlor DISHWASHER 1 77 78 G.C. 0 - - METRO SHELVING 1 78 79 G.C. 0 BCC-28-HC Avantco COUNTERTOP REFRIG DISPLAY CASE 1 79 80 G.C. 0 29059-86-1 Anets SDR-4 DOUGH SHEETER 1 80 81 G.C. G.C. IC 800 Advantco INDUCTION BURNER 1 81 82 3/4 14.6Kw 6A 1 115 G.C. 0 090904XD0702 Blodgett SHO-G DOUBLE DECK OVEN 2 82 83 11.23A 1 220 G.C. G.C. Pico Plus Chandley HEARTH OVEN 1 83 84 G.C. G.C. - - MIXER 20 QT. 1 84 85 12A 1 220 G.C. 0 11-1017-712 Hobart L-800 STAND MIXER - 80 QT. 1 85 2 3 4 5 6 7 3 4 1 EQUIPMENT PLAN - SCALE: 114"=1'-0" 10 �� TABLE � I L) TABLE 76 20P526 I 63 I � 105 �� _ _ _ \ KITCHEN � J � 63 \, AREA HEET R I � 104 A-2�1 83 58 I \�,;/ WASHING/ MIXER E II HOOD I /'"I� 77 5 PREP AREA 80QT. I� _ � ��i 80 I 41 P � _ 82 � ----J PREP SINK 52C 41 \(� / i HEA�H� -- o �(�NV 78 o HAND 84 ® 0�/ENS pyFp� ���� — — — � SINK 21 1P � 5 586 33'-6 1 / " 11'-10 3/4" 12'_0" 12'-1 1/2" 3'-3 1/4" 5 6 7 8 11 I 12 I 13 I 14 I 15 ►_� - B Main Street Commons 550 Main Street Edmonds, WA 98020 G 0 I N -�I - J N 10 1 /2" \ 0 16 �C C 603 Stewart Street suite 610 seattle, Washington 98101 206.466.5239 p 206.713.4076 m ksmith@smithco.org http://www.smithco.org/ Consultant E Consultant Registration I� Architect Registration 6294 G REGISTERED HITECT t KE MITH STA E OF WASHINGTON H Issues and Revisions No. Date Issues 1 0915 P1 PERMIT 2 101� �1 PERMIT CCRRECTICNS J Project Name Project Number 02016063.01 Description EQUIPMENT PLAN K Computer File K-1.O.DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, Larrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. ■ FJ