WEC-Heating_System_Sizing HitchensSimple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information The Hitchens Residence Kearsley Homes 17901 Vista Del Mar 6630 Norma Beach Road Edmonds, WA 98026 Edmonds, WA 98026 (425) 478-6380 r(a)kearsleyhomes.com Heating System Type: Electric Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Design Temperature Difference (AT) AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 4,759 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 42,831 Glazing and Doors U-Factor X Area = UA Instructions .30 1,481 444.21 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions .026 366 9.52 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions .027 2,277 61.48 Above Grade Walls (see Figure i) U-Factor X Area UA Instructions .056 2,631 147.34 Floors U-Factor X Area UA Instructions .029 290 8.41 Below Grade Walls (See Figure 1) U-Factor X Area UA Instructions .042 380 15.96 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions .303 43 12.88 Slab on Grade (see Figure 1) F-Factor X Length UA Instructions .36 182 65.52 Location of Ducts Instructions No ducts Duct Leakage Coefficient 1.00 Figure 1. Above Grade Sum of UA 765.31 46 Envelope Heat Load 35,204 Btu / Hour Sum of UA X AT Air Leakage Heat Load 21,278 Btu / Hour VolumeX 0.6XOTX.018 Building Design Heat Load 56,483 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 56,483 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 70,603 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13)