REVIEWED BLD2022-1025+HEATING+8.3.2022_8.10.40_AM+3029372BLD2022-1025 RECEIVED Ai In in 7(177 simple Heating system size: wasnington state - This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and& MENT Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling ItTM Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information Duffy Residence Brian and Nancy Duffy Heating System Type: O All Other systems OO Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions I Design Temperature Difference (AT) Edmonds AT= Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,359 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.6 28,887 Glazing and Doors U-Factor X Area = UA Instructions u-o.za J 0.280 708 198.24 Skylights U-Factor X Area = UA Instructions 0.50 40 20.00 Insulation Attic U-Factor X Area = UA Instructions LR49 � I 0.026 J 1,736 45.14 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions L R-38 Vented 0.027 189 5.10 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions L R-21 Intermediate � 0.056 2,411 135.02 Floors U-Factor X Area UA R-38 0.025 309 7.73 J Below Grade Walls (see Figure 1) U-Factor X Area UA R-21 interior 0.042 615 25.83 L Slab Below Grade (see Figure 1) F-Factor X Length UA LR-5 Thermal 0.570 95 54.15 Break at slab edge Slab on Grade (see Figure 1) F-Factor X Length UA Instructions L0.540 R-10 Perimeter � 86 46.44 Location of Ducts Instructions Duct Leakage Coefficient `Conditioned Space J 1.00 Sum of UA 537.64 Figure 1. Above Grade 46 Envelope Heat Load 24,731 Btu / Hour Sum of UA x AT Air Leakage Heat Load 14,351 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 39,083 Btu / Hour Air leakaqe + envelope heat loss Building and Duct Heat Load 39,083 Btu / Hour Ducts in unconditioned space: sum of buildino heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 48,853 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump ;ES (07101113)