Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD Energy Forms (2)
Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Pickering SFRs Gabi Muller / CB Anderson Architects 300, 302 & 304 6th Ave S, Edmonds, WA 98020 7209 Greenwood Ave N, Seattle, WA 98103 Units A, B and C 206-782-2911 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb,e n/a n/a Ceilingk 49' 0.026 Wood Frame Wall9,m,n 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wall"m 10/15/21 int + TB 0.042 Slab R-Value & Depth 1 10, 2 ft n/a 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Date Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. 02. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. ❑3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑4. Additions less than 500 square feet:.5 credits Table R406.2 Summary Option Description Credit(s) 1 a Efficient Building Envelope 1 a 0.5 1 b Efficient Building Envelope lb 1.0 1 c Efficient Building Envelope 1 c 2.0 1d Efficient Building Envelope id 0.5 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 5a 0.5 5b Efficient Water Heating 5b 1.0 5c Efficient Water Heating 5c 1.5 5d lEfficient Water Heating 5d 0.5 6 IRenewable Electric Energy 0.5 Total Credits *Please refer to Table R406.2 for complete option descriptions El 0 1.0 El El El El El El El El 0 1.0 El El El 0 1.5 El *1200 kwh 0.0 3.50 Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. ,10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. b Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. 'Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. M Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Pickering SFRs Gabi Muller / CB Anderson Architects 300 6th Ave S, Edmonds, WA 98020 7209 Greenwood Ave N, Seattle, WA 98103 Unit A AV am Phone 206-782-2911, e-mail gabi@cba-arch.com Heatinq System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 1,803 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 16,227 Glazing and Doors U-Factor X Area - UA Instructions u-o.zs 0.250 401 100.20 Skylights U-Factor X Area - UA Instructions 0.50 Insulation Attic U-Factor X Area - UA _.structions R-49 0.026 844 21.94 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value No selection 1 0 --- Above Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 INT plus R-4 ci � 0.043 1,801 77.44 Floors U-Factor X Area UA Instructions 0.025 563 14.08 Below Grade Walls (see Figure i) U-Factor X Area UA Instructions Select R-value � No selection 0 --- Slab Below Grade isee Fivure a F-Factor X Length UA Instructions Select conditioning � No selection 0 --- Slab on Grade (see Fiore a F-Factor X Length UA Instructions 0360 74 26.64 R-10 Fully Insulated . Location of Ducts Instructions Duct Leakage Coefficient No Ducts • 1.00 Sum of UA 240.30 Ficiure 1. Above Grade 46 Envelope Heat Load 11,054 Btu/Hour Sum of UA X dT Air Leakage Heat Load 8,062 Btu / Hour Volume 0.6XATX.018 Building Design Heat Load 19,115 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 19,115 Btu/Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 23,894 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Window, Skylight and Door Schedule Project Information Pickering SFRs 300 6th Ave S, Edmonds, WA 98020 Unit A Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Description Ref. U-factor casement or fixed 2636 0.25 casement or fixed 2640 0.25 casement & awning 2656 0.25 fixed 3020 0.25 casement or fixed 3046 0.25 casement & awning 3056 0.25 glass swing door 3'Ox7'0 0.25 glass sliding door 6'Ox7'0 0.25 opaque door 3'Ox7'0 0.25 opaque double door 4'Ox7'0 0.25 Contact Information Gabi Muller / CB Anderson Architects 7209 Greenwood Ave N, Seattle, WA 98103 Phone 206-782-2911, e-mail gabi@cba-arch.com Width Height Qt. Feet Inch Feet Inc" Width Height Qt. Feet Inch Feet Inch MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME Area UA Area UA Overhead Glazing (Skylights) Component Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Ket. U-tactor Width Height Qt. Feet Inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 400.8 100.19 0.25 Area UA 400.8 100.19 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Pickering SFRs Gabi Muller / CB Anderson Architects 302 6th Ave S, Edmonds, WA 98020 7209 Greenwood Ave N, Seattle, WA 98103 Unit B AV am Phone 206-782-2911, e-mail gabi@cba-arch.com Heatinq System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 1,919 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 17,271 Glazing and Doors U-Factor X Area - UA Instructions u-o.zs 0.250 309 77.25 Skylights U-Factor X Area - UA Instructions 0.50 Insulation Attic U-Factor X Area - UA _.structions R-49 0.026 865 22.49 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value No selection 1 0 --- Above Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 INT plus R-4 ci � 0.043 1,228 52.80 Floors U-Factor X Area UA Instructions 0.025 635 15.88 Below Grade Walls (see Figure i) U-Factor X Area UA Instructions Select R-value � No selection 0 --- Slab Below Grade isee Fivure a F-Factor X Length UA Instructions Select conditioning � No selection 0 Slab on Grade (see Fiore a F-Factor X Length UA Instructions 0360 74 26.64 R-10 Fully Insulated . Location of Ducts Instructions Duct Leakage Coefficient No Ducts • 1.00 Sum of UA 195.06 Ficiure 1. Above Grade 46 Envelope Heat Load 8,973 Btu / Hour Sum of UA X dT Air Leakage Heat Load 8,580 Btu / Hour Volume 0.6XATX.018 Building Design Heat Load 17,553 Btu/Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 17,553 Btu/Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 21,941 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Window, Skylight and Door Schedule Project Information Pickering SFRs 302 6th Ave S, Edmonds, WA 98020 Unit B Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Description Ref. U-factor casement or fixed 2636 0.25 casement or fixed 2640 0.25 casement & awning 2656 0.25 fixed 3020 0.25 casement or fixed 3046 0.25 glass swing door 3'Ox7'0 0.25 glass sliding door 9'Ox7'0 0.25 opaque door 3'Ox7'0 0.25 opaque double door 4'Ox7'0 0.25 Contact Information Gabi Muller / CB Anderson Architects 7209 Greenwood Ave N, Seattle, WA 98103 Phone 206-782-2911, e-mail gabi@cba-arch.com Width Height Qt. Feet Inch Feet Inch Width Height Qt. Feet Inch Feet Inch MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME Area UA Area UA Overhead Glazing (Skylights) Component Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Ket. U-tactor Width Height Qt. Feet Inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 308.5 77.13 0.25 Area UA 308.5 77.13 Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Pickering SFRs Gabi Muller / CB Anderson Architects 304 6th Ave S, Edmonds, WA 98020 7209 Greenwood Ave N, Seattle, WA 98103 Unit C AV am Phone 206-782-2911, e-mail gabi@cba-arch.com Heatinq System Type: O All other systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,413 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 21,717 Glazina and Doors U-Factor X Area - UA Instructions u-o.zs 0.250 397 99.25 Skylights U-Factor X Area - UA Instructions 0.50 Insulation Attic U-Factor X Area - UA _.structions R-49 0.026 844 21.94 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value No selection 1 0 --- Above Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 INT plus R-4 ci � 0.043 1,635 70.31 Floors U-Factor X Area UA Instructions 0.025 94 2.35 R-38 Below Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 int plus R-5 ci � 0.028 341 9.55 Slab Below Grade isee Fivure a F-Factor X Length UA Instructions 0.303 74 22.42 R-10 Fully insulated Slab on Grade (see Figure a F-Factor X Length UA Instructions 0.360 13 4.68 R-10 Fully Insulated 6 � Location of Ducts Instructions Duct Leakage Coefficient No Ducts • 1.00 Sum of UA 230.50 Envelope Heat Load 10,603 Btu/Hour Ficiure 1. SumofuAXAT Air Leakage Heat Load 10,789 Btu/Hour Volume 0.6XATX.018 Above Grade Building Design Heat Load 21,392 Btu/Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 21,392 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 26,740 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Window, Skylight and Door Schedule Project Information Pickering SFRs 304 6th Ave S, Edmonds, WA 98020 Unit C Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Uescription Het. U-tactor casement or fixed 2636 0.25 casement or fixed 2640 0.25 casement & awning 2656 0.25 fixed 3020 0.25 casement or fixed 3046 0.25 casement & awning 3056 0.25 glass swing door 3'Ox7'0 0.25 alass slidina door 6'Ox7'0 0.25 I waaue door 13'Ox7'010.25 I Contact Information Gabi Muller / CB Anderson Architects 7209 Greenwood Ave N, Seattle, WA 98103 Phone 206-782-2911, e-mail gabi@cba-arch.com Width Height Qt. Feet Inch Feet Inc" Width Height Qt. Feet Inch Feet Inch M©E©E M©EME ©©E©E ©©E©E M©EME ©©E©E M©EME MMEME MMEME ©©EME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME MMEME Area UA Area UA Overhead Glazing (Skylights) Component Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Ket. U-tactor Width Height Qt. Feet Inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 396.8 99.19 0.25 Area UA 396.8 99.19