Loading...
REVIEWED BLDBLD2021-0742+Energy_Calculations+5.30.2021_4.25.09_PM+2224125BLD2021-0742 simple meating System size: wasnington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washings Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systei Please complete the green drop -downs and boxes that are applicable to your project. As you make se values will be calculated for you. If you do not see the selection you need in the drop -down options, pl( energycode@energy.wsu.edu or (360) 956-2042 for assistance. n State Ene C s should be used to determine cooling loads. ctions in the drop-downPor each section, some SI'o'eEiyND Project Information Contact Information 702 CEDAR ST SCHUYLER TUTT EDMONDS WA 98020 EMAIL: SCHUYLER@MEDICIARCHITECTS.COM PHONE: 425 453 9298 EXT.113 Heating System Type: O All other systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds � AT =Indoor (70 degrees) -Outdoor Design Temp RECEIVED Area of Building Conditioned Floor Area Sep 03 2021 Instructions Conditioned Floor Area (sq ft) 3,466 CITY OF EDMONDS Average Ceiling Height Conditioned Volume DEVELOPMENT SERVICES Instructions Average Ceiling Height (ft) 10.3 35,700 DEPARTMENT Glazing and Doors U-Factor X Area = UA Instructions u-o.zo � 0.200 780 156.00 Skylights U-Factor X Area = UA Instructions 0.50 00 Insulation Attic U-Factor X Area = UA Instructions R-49 0.026 1,435 37.31 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions I No Vaulted Ceilings in this project. J Above Grade Walls (See Figure v U-Factor X Area UA Instructions 0.056 4,247 237.83 R-21 Intermediate Floors U-Factor X Area UA Instructions 0.025 1,444 36.10 R-38 � Below Grade Walls (See Figure v U-Factor X Area UA Instructions I 0.042 1,250 52.50 R-21 Interior J Slab Below Grade (se. Figure 1) F-Factor X Length UA Instructions 0.303 119 36.13 R-21 int Plus R-5 ci � Slab on Grade (See Figure v F-Factor X Length UA _ Instructions u � 0.360 0� R-10 Fully Insulated Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 555.87 Envelope Heat Load 25,570 Btu / Hour Figure 1. Sum of UA x OT Air Leakage Heat Load 17,736 Btu/Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 43,306 Btu / Hour 1 Air leakage + envelope heat loss Building and Duct Heat Load 43,306 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 60,628 Btu / Hour Buildinq and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)