Loading...
APPROVED BLD ENG FIR RESUB 1-BLD2023-0433+Architectural_Plan+7.19.2023_3.06.40_PM+3675715ence wttaceccesso w1Tang1le ml* (A U) SITE & ZONING DATA BUILDING CODE PROJECT TEAM --- ""-CO RIM-171.17 PERMIT APPLICANT / PROJECT CONTACT: PETER TANG (PROJECT OWNER) SHALL BE RESPONSIBLE FOR CODE COMPLIANCE: THIS RESIDENCE SHALL BE CONSTRUCTED TO PROVIDE FULL COMPLIANCE TO: THE OWNER APPROVED BY PLANNING PETER & JIA TANG 07-20-2023 1 SD ; >\'�q', PLAN REVIEW FILLING OUT ALL APPLICABLE PERMIT APPLICATIONS AND 2018 INTERNATIONAL RESIDENTIAL CODE WITH STATE AMENDMENTS, 2018 INTERNATIONAL MECHANICAL CODE (INCLUDING INTERNATIONAL FUEL GAS CODE) 644 BELL ST. Jul 272023 -----------------------------------r-------;�------------------------------------------------ MOTES: APPPPPRD-�E-D �Al� SON -DLT�OIVS: 1 1. A SEPARATE P IT SUBMITTAL IS FOR A 1 ,' SHALL SUBMIT ALL APPLICATIONS AND PERMIT DRAWINGS TO WITH STATE AMENDMENTS, 2018 INTERNATIONAL FIRE CODE WITH STATE EDMONDS, WA 98020 RESIDENTIAL SPMWKLER SYSTEM IS REQUIRED. A CITY OF EDMONDS via MyBuildingPerm it.com. AMENDMENTS, 2018 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS, 2018 Tel: 206-372-2584 ' ' RECOMMENDED FLOW -THROUGH DESIGN WILL ANY REQUESTS FROM CITY FOR ADDITIONAL INFORMATION OR WASHINGTON STATE ENERGY CODE (WAC 51-11). Fax:. --------------------------------1---------------------------r------------------------------ 1 WPM ' WPM-M€ TST'E-CfFI&1 ONS-PND-REPrUCE EQUIPMENT FORMS SHALL BE DIRECTED TO PETER TANG (CONTACT Contact: PETER TANG I I ( I AND CONTINUAI, G MAINTENANgE REQUIRMENTS. INFORMATION BELOW.) DEFERRED SUBMITTALS: ALL DESIGN -BUILD DRAWINGS AND APPLICATIONS FOR THE FOLLOWING PERMITS ARCHITECT 1 1 � ; PROVIDE A MIN�(MUM COMBINATII,ON WATER PROJECT SUMMARY: WILL BE SUBMITTED BY THE GENERAL CONTRACTOR AT A LATER DATE: a) ELECTRICAL, b) MECHANICAL, c) PLUMBING, CARL J. COLSON - ARCHITECT PLLC 2502 WASHINGTON BLVD. 1 ' Daley Street SERVICE OF O,NE INCH (1") METER AND ONE AND I , �� ----------------------- ' SS I ________ ONE HALF (1 /2) SERVICE LINE �R SHOW THAT r DEMOLISH EXISTING SINGLE FAMILY RESIDENCE SWIMMING d) WATER METER, e) SIDE SEWER. g) FIRE SPRINKLER (IF REQUIRED) _ ANACORTES, WA 98221 Zone Corner Fla ; i THEDZ3 f�R1V6FiRFPF'OTECTiONS NEEDS POOL, STORAGE SHED & DRIVEWAY. - g - "" " i ; Approved CAN BE MET/WITH A SMALLER SERVICE. 2E' CONSTRUCT NEW SINGLE FAMILY RESIDENCE (2 STORY) w/ BUILDING CODE Tel: 360-873-8339 Fax: - Setbacks: Required Actual a- , ' I II DFM Chris $Rrt 2.4 INCH ADRESS CHARACTERS WITH 1/2 INCH ATTACHED 2 CAR GARAGE. RESIDENCE HAS 4 BEDROOMS AND 4-1/2 BATHROOMS. 2018 INTERNATIONAL RESIDENTIAL CODE Contact: CARL COLSON 201 I STROKE T BE INSTALLED ON THE HOUSE VISIBLE South County Fire I FROM TH STREET IN CONTRASTING COLOR TO CONSTRUCT AN ATTACHED ADU 2 STORY w/ ATTACHED 1 CAR ( ) ENERGY CODE Front CIVIL ENGINEER o t Date: 07/20/2023 THE BA GROUND. ADDITIONAL RESS SIGNS GARAGE. ADU HAS ONE BEDROOM AND ONE BATHROOM. 2018 WASHINGTON ENERGY CODE W/ PRESCRIPTIVE PERFORMANCE RAM ENGINEERING 5 Sides , _ 7,W i I i MY BE UIRED IF NOT VISIBLE 1F0 M THE PROJECT ADDRESS: OCCUPANCY GROUP R_3 16531 13th Ave W, SUITE A108 LYNNWOOD, WA 98037 Rear 1Y. . ---------- 1 I I EXISTING CURB TO BE i I STREET/. �� 1 l REMOVED FOR NEW DRIVEWAY DFM BI�RT 1 840 DALEY ST. Tel: (425) 678-6960 ------ -- ------- --------------- --------------------------- EDMONDS, WA 98020 CONSTRUCTION TYPE Fax: Other LL GAS ----_-----; i� ii j� GPM ' GPM--------- 717,4--- PROJECT OWNER: TYPE V-B SEPARATIONS Contact: ROB LONG ; eight 2 5 __; STRUCTURAL ENGINE O i 1- �,, I 1 S� _� L_ 176 � 24�5 / VALVE �, 1 PETER &JIA TANG 644 BELL ST THERE IS AN ATTACHED GARAGE TO AT THIS RESIDENCE SEE GARAGE/LIVING AREA AND SINGLE FAMILY RESIDENCE / ADU SEPARATION SIDESWAY ENGINEERING 20305 87th Ave W i l MTR. EXISTING TELEPHONE POLE F+� " LJ J _ _ _ Property Li :N89d 5_9�37 W 74.93 _ _ - - - EDMONDS, WA 98020 206-372-2584 NOTES ON SHEET A-2.1 AND A-4.1. EDMONDS WA 98026 1 ' I ELECTRICAL SERVICE TO , NEW HOUSE & ADU SHALL WALL RATINGS AT DETACHED SINGLE FAMILY RESIDENCES INTERIOR BEARING & NON -BEARING WALLS: NO RATING REQUIRED Tel: (425) 673-4160 Fax: o I EXISTING WALKWAY I a_ Property Information I 1 1 a_ BE UNDERGROUND FROM Parcel ID: 00434208101000 PARCEL NUMBER: Contact: CHRIS BERNARD, P.E. _ EXISTING TELEPHONE N 00434208101000 WALLS BETWEEN SINGLE FAMILY RESIDENCE & ADU: ONE HOUR o i POLE / Property Address: 840 Daley St EXTERIOR BEARING WALLS: NO RATING REQUIRED / N i / City: Edmonds, WA 174 LEGAL DESCRIPTION: EXTERIOR NON -BEARING WALLS: NO RATING REQUIRED I� DRAWING LIST NEW SINGLE FAMILY 1,�6 Zip Code: 98020 CITY OF EDMONDS BLK 081 D-00 -LOTS 10-11 & W1/2 LOT 12 SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF CEILINGS - FLOORS: NO RATING REQUIRED, EXCEPT @ GARAGE & ADU CEILINGS BETWEEN SINGLE FAMILY RESIDENCE & ADU: ONE HOUR SEE GARAGE/LIVING AREA SEPARATION NOTES ON SHEET A-2.1 AND A-4.1. SEE CIVIL ENGINEERING DRAWINGS FOR ALL GRADING, STORM WATER PLAN, AND UTILITY PLAN DRAWINGS AND CALCULATIONS. DRAWINGS FOR ALL DRAWINGS J 1 I FRONT BLDG. SETBACK 1 I RESIDENCE DRIVEWAY Taxpayer: Peter &Jia Tan I 1 g 5 - ' Pt. ENTRY WALKWAY I � � Owner: Peter &Jia Tang N I 5' DE BLDG. SETBACK 1 5' SIDE BLDG. SETBACK 176.38' WASHINGTON. STAIRWAY / STEPS CONSTRUCTION SEE STRUCTURAL STRUCTURAL AND STRUCTURAL CALCULATIONS. I I Size Gross Acres): 0.19 ( ) 1 PROJECT ZONING: WOOD CONSTRUCTION W/WOOD RISERS AND TREADS. • SEE SURVEY DRAWING FOR ALL EXISTING SITE CONDITIONS 7 - 1 1 / Pt. A 1 61 ' - 0" 1 6' - 9 1 /8" ► � Single Family Residence Area I 1 RS -6 SEE STAIR NOTES ON SHEET A 4.1 FOR ADDITIONAL INFORMATION. DRAWING AND SURVEY DATA l , -- - ---- __ - -------- F -- --- Level 1 Living Area: 1555 s.f. LOT SIZE ACCESSIBLE UNITS ARCHITECTURAL A 1.1 PROJECT DATA, SITE PLAN &COVER SHEET NOTES I ; PORCH INSTALLEDE., . HARG R 5' - 0" Level 2 Living Area: 1720 s.f. 10 1 L----- - - 1- ---- Total Residence Area: 3275 s.f. i LINE OF 11 PER THE 2018 INTERNATIONAL RESIDENTIAL CODE, SINGLE FAMILY RESIDENCES °' 1 1 ADU Area o LOT SIZE PER CITY RECORDS 0.19 ACRES LOT SIZE PER SURVEY 8201 s.f. ARE NOT REQUIRED TO BE ACCESSIBLE UNITS AS DEFINED BY THE ACCESSIBILITY SECTION OF THE CODE. A-1.2 PROJECT GENERAL NOTES A 1.3 EXISTING SITE SURVEY EXISTING HOUSE -- � i ; Single_ oBEREMovED ++ - �, ADU @Level 1: 104 s.f. L J CD A-1.4 3D VIEWS ADU @ Level 2: 625 s.f. ' ' Family LOT COVERAGE RECYCLE & GARBAGE STORAGE AREAS A 2.1 ARCHITECTURAL FOUNDATION PLAN A-2.2 LEVEL 1 FLOOR PLAN ; T- Total ADU: 729 s.f. 0 Re$Idencel FOOTPRINT: 2868 s.f. COVERAGE: 34.97% (35% MAXIMUM ALLOWED) THIS RESIDENCE WILL STORE GARBAGE AND RECYCLE MATERIALS IN BINS WITHIN THE GARAGE. A-2.3 LEVEL 2 FLOOR PLAN A-2.4 ROOF PLAN i � 1 N i - 0 1 r Lot Area i I? O I -0 z 1 Lot Size: 8201 s.f. A-2.5 ROOF SCISSOR TRUSS PLAN & 2nd FLOOR TRUSS PLAN i bo 1 0 1 THIS LOT COVERAGE AREA INCLUDES HOUSE FOOTPRINT, HAZARDOUS MATERIAL i CO a; - -_ o 35% Coverage Max: 2870 s.f. g GARAGE FOOTPRINT FRONT PORCH AND REAR COVERED THIS IS A RESIDENTIAL PROJECT AND NO HAZARDOUS MATERIAL WILL BE HANDLED A-2.6 LEVEL 1 LIGHTING / DETECTORS / VENTILATION NOTES A 2.7 LEVEL 2 LIGHTING /DETECTORS i 1 _ TWO CAR GARAGE z LINE OF EXISTING 1 Lot Coverage i J -°� PORCH OR STORED AT THIS PROJECT. A-3.1 EXTERIOR ELEVATIONS: NORTH AND SOUTH >, HOUSE TO BE REMOVED LINE of EXISTING HOUSE Footprint: 2868 s.f. 174 TO BE REMOVED BUILDING HEIGHT: BUILDING HEIGHT INSULATION VALUES PER WASHINGTON STATE ENERGY CODE, THE INSULATION VALUES ARE R-21 FOR WALLS, R 30 FOR FLOORS OVER UNHEATED SPACER 10 RIGID INSULATION BELOW A-3.2 EXTERIOR ELEVATIONS: EAST AND WEST A-4.1 BUILDING SECTION & NOTES A-4.2 EXTERIOR DETAILS � a) � 1 -1>1 Coverage: 34.97% o - i - o Height Calculations x i r- --- --I--� --- - --- -- -- 1 , SEE NOTES TO THE RIGHT OF THE SITE PLAN @RIGHT FOR ( ) CONCRETE FLOOR SLABS, AND R-49 IN ATTIC SPACE. A-4.3 INTERIOR DETAILS I � I � A = 174.58 I , L �- PROPOSED BUILDING HEIGHT. A-5.1 DOOR & WINDOW DETAILS & LEGENDS _________ __ ,----- ------ - x B = 176.38' PUMP SEE SOUTH EXTERIOR ELEVATION FOR LINES SHOWING HEATING &HOT WATER SYSTEM A-6.1 WASHINGTON STATE ENERGY CODE CALC'S. �I�F--�rHOE'AT C = 176.53' I HEST ��'�. ul� - RADu D 175.48' PROPOSED AND MAXIMUM RIDGE HEIGHT. THIS RESIDENCE SHALL BE HEATED BY AN ELECTRIC HEAT PUMP HEATING / = PUt P L �',, COVERED Total = 702.97 div. by 4 = 175.74 BUILDING HEIGHT WILL BE 24' 5-3/4" ABOVE THE AVERAGE BUILDING ELEVATION of 175.74'. COOLING SYSTEM WITH FRESH AIR INTAKE FOR WHOLE HOUSE VENTILATION . HOT WATER SHALL BE PROVIDED BY AN ELECTRIC HEAT PUMP WATER HEATER PER SUBMITTALS 1 ��` PORCH \/ X Avg. Grade = 175.74 I \ �� F ENERGY CODE CALCULATIONS ON SHEET A-6.1. i 1 ,� ;; Proposed Ridge Elevation = 200.21' I �� "' THE FOLLOWING NOTES SHALL SERVE AS A GUIDE TO THE ; I I i Oo Maximum Ridge Elevation = 200.74' I ��� CUT AND FILL: CUT FOR THE PROPOSED FOOTINGS EXCAVATION. REFER TO GLAZING U-VALUES ALL NEW WINDOWS / GLAZING SHALL HAVE A U-VALUE OF 0.28 CONTRACTOR TO VERIFY EACH CONDITION WITH THE PRODUCT MANUFACTURER OR SUPPLIER, AND/OR LOCAL JURISDICTIONS FOR ' I i PATIO Y-�� - ° 1 (Average Grade + 25') I �� i `� ���� D CIVIL ENGINEERING GRADING PLAN FOR ALL GRADING THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE OWNER x 4� � 1 Impervious Surface WASHINGTON ENERGY OR PROCEEDING WITH WORK. i i\�� - - - - x INFORMATION STATE CODE .� ,% r - LINE OF SWIMMING House & ADU = 3160 s.f. CRITICAL AREAS /WETLANDS THERE ARE NO CRITICAL AREAS OR WETLANDS ON THIS SEE SHEET A-6.1 FOR CALCULATIONS AND ENERGY CODE OPTIONS SELECTED FOR THIS RESIDENCE AIR LEAKAGE TESTING THE ITEMS OUTLINED BELOW ARE NOT NTENDED TO BE AN EXHAUSTIVE ANALYSIS OF ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE AS A BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE ALL FENCES SHOWN ARE POOL TO BE REMOVED % i (includes roof overhang TO BE REMOVED AND I i I ��� ��� LINE FOR CALCULATING , i i &covered porches) REPLACED WITH A NEW 6' p ) HIGH WOODEN FENCE @ I 1 ' Pt. D BUILDING HEIGHT Entry Driveway = 477 s.f. 1 PROPERTY REFER TO SHEET A-2.2 FOR NOTES ON AIR BARRIER / AIR INFILTRATION. AIR CONSTRUCTION PROCESS. 1. REVIEW MANUFACTURER'S PRODUCT LITERATURE FOR PROPERTY PERIMETER 175.48' I ADU Driveway 369 s.f. I ____ ____ __ _____\ _----_ _____® __ F07t1FfEEV_ Pt. Y = Open Patio = 118 s.f. LEAKAGE TESTING SHALL BE PERFORMED PER WASHINGTON STATE ENERGY CODE i 1.117.6.�3' CHARGER BUILDING SETBACKS: SECTION R402.4 INSTALLATION INSTRUCTIONS UNIQUE TO THE PROJECT x ,v� r - 1 Entry Walkway = 74 s.f. FRONT YARD (MIN. 201) CONSTRUCTION TYPE. A. HVAC EQUIPMENT AND DUCTING "' I , x J (Paved areas do not 0 SIDE YARD SETBACKS (5') DUCT TESTING T ; r include portion of paving i t i p p g REAR YARD (20') DUCT TESTING SHALL BE PERFORMED PER WASHINGTON STATE ENERGY CODE SECTION R403.3 B. RECESSED AND SEMI -RECESSED LIGHTING C. ALL EXHAUST FANS AND DUCTING LO , x �-------GPM--f----- - _ ___ ---- - Y overhangs) - -_---- it", ADU covered b roof overhan s PARKING CALCULATIONS FIRE INSULATION ENERGY CODE D. BATH TUB AND SHOWER ENCLOSURES E. RECEPTACLE BOXES (I.E., T.V., TELEPHONE, ELECTRICAL, _. o = 1 1 Driveway Total 4198 s.f. o 15' REAR BLDG. SETBACK 1 (4198 divided by 8120 = 51.78 /o) THIS RESIDENCE HAS HAS TWO SPACES (19' x 8'-6") IN AN ' ' PLUMBING) ATTACHED GARAGE AND TWO SPACES IN THE DRIVEWAY. FIRE PROTECTION SYSTEM 2. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY WITH 1 0 / 7---j LANDSCAPE COVERAGE THE ADU HAS ONE SPACE (19'-0" x 8'-6" MIN.) IN ITS ATTACHED THIS RESIDENCE WILL BE BE FIRE SPRINKLERED PER CITY OF EDMONDS BUILDING � LOCAL JURISDICTIONAL REQUIREMENTS. i x Landscaped Area 3959 S.F. rs, i 1 1 i p GARAGE AND ONE SPACE IN ITS DRIVEWAY ACCESSED FROM ALLEY. CODE / FIRE MARSHAL REQUIREMENTS INSULATION DATA /ENERGY CODE REQUIREMENTS A. GAS UTILITY B. TELEPHONE UTILITY I I T ' (3959 / 8201 = 49.7%) o Property L ine: N89d 58 35 E 74.90 , Landscape Percentage 48.27 /o C. CABLE T.V. UTILITY x - - - -x - - --x�-__--------------------j INSULATION VALUES DETERMINED BY PRESCRIPTIVE APPROACH PER 2018 D. POWER UTILITY ................... _. . . ............. SITE WORK: WASHINGTON ENERGY CODE. F. LOCAL UTILITY DISTRICT The following documentation shall be available on DEMOLITION OF EXISTING HOUSE, GARAGE, SWIMMING POOL, THIS HOUSE WILL BE HEATED WITH GAS FIRED FURNACE PROVIDING WARM AIR THROUGH METAL DUCTS TO VENTS AND HAS FOR: 1.SANITARYSEWER Separateplumbing :site for the building inspector: ; ENGINEERING DIVISION and sprinkler permit required. APPROVED RESUB DRIVEWAY AND STORAGE SHED. STRUCTURAL FILL AT LOCATION OF EXISTING SWIMMING CONTROL. REFER TO THE ENERGY CODE CALCULATIONS FOR REQUIRED 2. WATER SUPPLY PlDease Gravel AllE! ❑ coE APPROVED ARCHITECTURAL PLAN sEr pply via MyBuildingPermit.COm ! . 2s�'� 09/11/2023 INSULATION VALUES. 4. THE FOLLOWING ITEMS SHALL BE DESIGN/BUILD SYSTEMS ❑ . Jul 19 2023 ■ COE APPROVED STRUCTURAL PLAN SET POOL. EXCAVATION FOR DOUNDATION FOOTINGS / CRAWLSPACE @ CONSTRUCTION EROSION CONTROL SHALL BE APPLIED FOR BY THE CONTRACTOR AT A LATER D TE. THE CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM TO TH ! ❑COE REVIEWED CALCULATION PACKET SEE CIVICS FOR CITY OF EDMONDS DEVELOPMENT SERVICES ❑ ENERGY CREDIT WORKSHEET �- DEPARTMENT PROPOSED NEW HOUSE, ADU, & NEW GARAGE, AND REGRADING AT AREA OF NEW COVERED PATIO. CONSTRUCTION EROSION CONTROL MEASURES MUST BE IN PLACE AND APPROVED BY BUILDING DEPARTMENT PRIOR TO ANY EARTH DISTURBANCE. CALL OWNER, WHICH COMPLIES WITH ALL JURISDICTIONAL REQUIREMENTS. x ; F] SITE PLAN UTILITY AND C F] CIVIL PLAN FRONTAGE _ BUILDING DEPARTMENT TO SCHEDULE AN INSPECTION APPOINTMENT FOR THIS A. BUILDING ELECTRICAL Site Plan ❑ CONSTRUCTION REFER TO LANDSCAPE ARCHITECTS LANDSCAPE PLAN FOR SCOPE AND AREAS OF ALL SITE GRADING ITEM. B. PLUMBING SYSTEM .2 • ❑ Buildin Department � IMPERVIOUS SURFACE CALCULATIONS: ADDRESS SIGNAGE TEMPORARY ADDRESSING OF THE RESIDENTIAL UNITS SHALL BE CLEARLY VISIBLE C. MECHANICAL /HEATING SYSTEM �/ /* **************************************************************************** *�*** I j � �� _ � ��_��� ! ■ CITY OFEDMONDSBUILDINGDEPARTMENT2021 � SITE PROJECT NEW SFR AND ADU Edmonds center mhAve% Glen St Q Glen11 (SEE CALCULATIONS ON SITE PLAN @ SHEET A-1.1 - DRA @ RIGHT SIDE OF THIS PAGE) ION OF COMBUSTIBLE MATERIALS. *" **** *" "**" *********************" *`"**" For the Arts North 0 840 Daley St, becketts oa�rsr DESIGN DATA A L. SIN T SI I U S LL BE CLEARLY H R 0 TO ERTIFICATE OF GIWc', LIOA'� Address Holy Trinity Edmonds Edmonds, WA98020 840 DALEY ST nding North�SITE • p '�i, I S Energy Code Comp lance Information. '_ spraguest __ Woodsts s � �'✓`�eodstone Taverns s (SEE STRUCTURAL DRAWING SHEET S-1.1 FOR COMPLET DESIGN LOADS CHART APPRO R R ILDING NUMBERS 0 APPROVDII I�N PLACED IN A POSI ON T AINLY • R-values for all envelope com nents. Owner lue f I 'tio a � �-- 3 < TANG e 4 Hummingbi �ppa ) M �!S% Z 2 1 Z Hill Park _ PROJECT SEISMIC: SEISMIC DESIGN CATEGORY: D LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRO IN G ERT if a et f I Ener t S p 6. y P, rove np pSaltandlroi ��� Date 08/16/2023 '(I WIND:110 MPH EXPOSURE: CEomonds0 S� I BACKG OUN No"4sm=s ABIC � ORAL ABETICAL LETTERS. ate r it e g p WSEC 4. • Indicate required duct testing per WSEC R403.3. Term SITE EdmofidsFerryTerminal Frances Anderson Center _ �d Q Edmonds ® Q EdmondsWIND i a Driftwood Players SNOW LOADS 25 PSF CDESIGN LOADS PER CHAPTER 3 OF 2018 INTERNATIONAL S L U N H S 0 H H WITH A MINIM WIT 1 .7 SS I BY MEANS OF RI TN D IVD C E ROM THE PUB Building g JOB SITE fficial Cascadia rtMuseum p ' EIr(�C/ waaycaRsf + oayronsc Dayton Edmonds Library Dayton �, 4 m RESIDENTIAL CODE MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL B SED TO IDENTIF E Permit N Mapleway nnaa``�� ti Z-cobsen's Marine Map m hupleSt MW mber `G `7tiY� A`TI'f�L AAA a L- L-%.R %MO 11% 5 Ili Ili -45 1VaP9Ili- AREA VICINITY MAP %.�o %J Carl J. Colson -Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Drawings for Conditional Use Permit for ADU 4-19-2023 Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Tit]( - over Sheet -Site Plan - Project Data 77543 REGISTERS 1ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 11 I7-18-2023 I PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 09/12/17 Drawn By Author Cover Sheet - Site Plan - Project Data Scale As indicated Sheet Plot Date 7/17/2023 1:48:53 PM www.CarIColsonArchitect.com GENERAL NOTES FIRE SAFETY ISSUES CASEWORK, PRESSURE TREATED WOOD, & FINISHES 1. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES THAT EXIST WITHIN THE DRAWINGS. 2. ALL METHODS, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE 2018 INTERNATIONAAL RESIDENTIAL BUILDING CODE. 3. THE CONTRACTOR SHALL INDEMNIFY AND HOLD CARL J. COLSON - ARCHITECT PLLC AND THEIR CONSULTANTS HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE CONTRACTOR, HIS AGENTS, EMPLOYEES OR SUBCONTRACTORS. 4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT HIS OWN EXPENSE. 5. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS SHALL BE CORRECTED BY THE SUBCONTRACTOR AT NO EXPENSE TO THE OWNER OR CARL J. COLSON - ARCHITECT PLLC. 6. ONLY APPROVED "PERMIT SET" MARKED DRAWINGS INCORPORATING ALL ADDENDA AND DIMENSIONAL CLARIFICATIONS SHALL BE USED DURING THE EXECUTION OF THE WORK. 7. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (W/ EXCEPTION OF SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN "OR EQUAL" BASIS. ANY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO CARL J. COLSON - ARCHITECT PLLC OR OWNER IN WRITING FOR APPROVAL WITHOUT DELAY OF SCHEDULE. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATIONS AND COORDINATION OF SUBCONTRACTORS' WORK TO SECURE COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS. THIS INCLUDES THE ACCURATE LOCATION OF STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, AND MISCELLANEOUS EQUIPMENT. 9. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING THE BUILDING CLEAN. ALL WINDOWS AND GLASS SHALL BE WASHED, ALL CARPETS SHALL BE CLEANED (AS NECESSARY) AND VACUUMED. ALL FLOORS SHALL BE CLEANED AND SWEPT. CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGED ITEMS PRIOR TO FINAL INSPECTION. BUILDING CODE NOTES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH THE APPLICABLE SAFETY CODES. 2. THE CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS AND FEES. 3. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE DESIGN -BUILD AND SHALL BE UNDER SEPARATE PERMITS TO BE OBTAINED BY THE CONTRACTOR. 4. ALL WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ANY AND ALL CONFLICTS IN WRITING. 5. THE CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AS REQUIRED BY CODE. DIMENSIONS AND FRAMING NOTES 1. ALL DIMENSIONS SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY CARL J. COLSON - ARCHITECT PLLC OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. DO NOT SCALE THE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING THE WORK. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY CARL J. COLSON - ARCHITECT PLLC IF ANY DISCREPANCIES ARE FOUND. 3. ALL INTERIOR FRAMED WALL DIMENSIONS ARE SHOWN TO FACE OF STUD, UNLESS NOTED OTHERWISE. DIMENSIONS TO THE EXTERIOR SIDE OF WOOD FRAMED WALLS ARE TO THE FACE OF STUD. 4. OFFSET STUDS WHERE REQUIRED TO MAKE STRAIGHT AND CONTINUOUS WALL PLANES, ESPECIALLY AT FLOOR OPENINGS. ALL PARTITIONS AND WALLS SHALL EXTEND FULL HEIGHT TO STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. 5. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL AND ELECTRICAL EQUIPMENT WITH THE RESPECTIVE SUBCONTRACTORS PRIOR TO CONSTRUCTION. 6. THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT, DOORS, AND WINDOWS. 7. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL BE 5" FROM FACE OF STUD TO EDGE OF DOOR OPENING. 8. FINISH FLOOR ELEVATION REFERS TO TOP OF CONCRETE SLAB OR TOP OF PLYWOOD FLOOR DECK. 9. REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE AND SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT LIMIT APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY APPLY TO OTHER SAME OR SIMILAR CONDITIONS NOT REFERENCED. 10. KITCHEN LAYOUT IS SCHEMATIC ONLY. COORDINATE KITCHEN LAYOUT WITH OWNER. CABINET STYLES AND MATERIALS SHALL BE SELECTED BY OWNER / CONTRACTOR. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WALL BLOCKING AND BRACING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 12. ALL NEW CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2009 SEATTLE RESIDENTIAL BUILDING CODE AND STATE OF WASHINGTON BUILDING CODE AND ALL APPLICABLE SEISMIC REQUIREMENTS. ARCHITECTURAL SITE NOTES 1. REFER TO SURVEY (IF SURVEY WAS COMPLETED FOR THIS PROJECT) AND/OR CIVIL ENGINEERING DRAWINGS FOR ADDITIONAL NOTES AND INFORMATION FOR EXISTING CONDITIONS. 2. VERIFY ALL UNDERGROUND UTILITIES AND SITE GRADES PRIOR TO CONSTRUCTION. 3. COORDINATE PROPERTY CORNERS WITH SURVEYOR. 4. CONTRACTOR SHALL VISIT THE SITE AND APPRAISE HIMSELF/ HERSELF OF THE EXISTING CONDITIONS AND SEQUENCE PRIOR TO ANY CLEARING OR DEMOLITION WORK. 5. VERIFY ALL TOP OF SLAB ELEVATIONS AT ALL BUILDING AND PROPERTY LINES. 6. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL PADS AND BASE, ALONG WITH POWER, WATER AND / OR DRAINAGE INSTALLATIONS BEFORE PROCEEDING WITH THE WORK. 1. FIRE BLOCKING SHALL BE REQUIRED AT ALL LOCATIONS REQUIRED BY THE 2018 INTERNATIONAL RESIDENTIAL BUILDING CODE. 2. ALL BEDROOMS SHALL HAVE WINDOWS THAT COMPLY WITH 2O18 INTERNATIONAL RESIDENTIAL BUILDING CODE EGRESS REQUIREMENTS. REFER TO WINDOW SCHEDULE FOR ALL WINDOW SIZES AND EGRESS REQUIREMENTS. 3. ALL NEW BEDROOMS (AND AREAS ADJACENT TO BEDROOM ENTRY) SHALL HAVE SMOKE DETECTORS (W/ BATTERY BACKUP) HARDWIRED INTO THE ELECTRICAL SYSTEM. 4. OCCUPANCY SEPARATION WALLS ARE REQUIRED IN THIS PROJECT BETWEEN THE LIVING SPACE AND ATTACHED GARAGE AT EACH RESIDENTIAL UNIT. 5. NO AREA SEPARATION WALLS ARE REQUIRED IN THIS PROJECT. 6. CONSTRUCTION TYPE: TYPE V-B. 7. ADDRESSES SHALL BE POSTED ON THE BUILDING AS REQUIRED BY THE 2018 INTERNATIONAL RESIDENTIAL BUILDING CODE AND APPLICABLE FIRE SAFETY CODE. 8. ALL REQUIRED FIRE RATED DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY. FIRE SPRINKLER 1. THIS RESIDENCE IS REQUIRED TO HAVE A FIRE SPRINKLER SYSTEM (BASED ON SQUARE FOOTAGE) AS REQUIRED BY THE CITY OF EDMONDS. MOISTURE CONTROL 1. ALL INTERIOR FACE OF EXTERIOR WALLS AND CEILINGS SHALL BE PAINTED WITH A P.V.A. PAINT TO MINIMIZE MOISTURE PENETRATION OF EXTERIOR WALLS OR CEILING INSULATION SPACE, 2. WALLS: INSERT STAPLED BATTS WITH A PERM RATING EQUAL TO OR LESS THAN 1.0 MAY BE INSTALLED IF STAPLES ARE PLACED MAXIMUM 8" O.C. AND GAPS BETWEEN THE FACING AND FRAMING DO NOT EXCEED 1/16". 3. THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE: EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS: OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS, AND ROOF. 4. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO OR FROM THE BUILDING ENVELOPE. MANUFACTURED WINDOWS SHALL HAVE AIR INFILTRATION RATES NO GREATER THAN 0.5 CFM. ELECTRICAL / MECHANICAL / PLUMBING 1. HEATING AND COOLING WILL BE PROVIDED BY AN ELECTRIC HEAT PUMP HEATING / COOLING SYSTEM INSTALLED IN THE MECHANICAL ROOM AT THE UPPER LEVEL. HOT WATER WILL BE PROVIDED BY AN ELECTRIC HEAT PUMP WATER HEATER LOCATED IN GARAGE. MECHANICAL SUBCONTRACTOR TO PROVIDE HEATING LOAD CALCULATIONS TO APPLICABLE BUILDING DEPARTMENT FOR APPROVAL AND PERMIT PRIOR TO CONSTRUCTION. GENERAL CONTRACTOR AND MECHANICAL SUBCONTRACTOR SHALL REVIEW ALL DRAWINGS PRIOR TO CONSTRUCTION TO BEST DETERMINE ROUTING OF ALL NEW DUCTWORK AND VENT LOCATIONS. ALL VENTING SHALL BE IN CONDITIONED SPACE. 2. ALL PLUMBING FIXTURES SHALL COMPLY WITH FLOW RATES AS REQUIRED BY THE APPLICABLE WASHINGTON STATE PLUMBING CODE. THE REDUCED FLOW FIXTURE RATES ESTABLISHED BY THE WASHINGTON STATE ENERGY CODE SHALL NOT APPLY, UNLESS NOTED AS AN ENERGY CREDIT OPTION ON SHEET A-6.1 3. PROVIDE LAUNDRY ROOM WITH MECHANICAL VENTILATING SYSTEMS AS SHOWN (5 AIR CHANGES PER HOUR PER WASHINGTON STATE ENERGY CODE). 4. ALL SOLDER USED IN PLUMBING CONNECTIONS, SHALL BE LEAD FREE AS DEFINED BY WAC STANDARDS 51-16-060. 5. ALL ELECTRICAL TRIM TO BE COLOR SELECTED BY OWNER. 6. CLOTHES DRYER MOISTURE EXHAUST VENTS SHALL COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR MAXIMUM HORIZONTAL AND VERTICAL LENGTHS AND AS PER UNIFORM MECHANICAL CODE. 7. ALL INTERIOR PLUMBING WALLS SHALL BE INSULATED FOR SOUND CONTROL. MATERIALS SEE NOTE SECTION "MOLD CONTROL" FOR INFORMATION ON GYPSUM BOARD PRODUCTS. 1. SHOWER / TUB UNITS SHALL BE AS SPECIFIED ON DRAWINGS. COORDINATE THIS ITEM PRIOR TO PROVIDING BID PRICE. 2. ALL GYPSUM WALLBOARD IN BATHROOMS SHALL BE WATER RESISTANT. 3. ALL WEATHER EXPOSED SURFACES SHALL HAVE A WEATHER -RESISTANT BARRIER (AS INDICATED ON SHEET A-4.1) INSTALLED BEHIND EXTERIOR SIDING TO PROTECT INTERIOR WALL MATERIALS. SEE SECTION DRAWINGS FOR ADDITIONAL INFORMATION. UCTIO 4. WOOD SUPPORTS IN CONTACT WITH SOIL OR MASONRY OR LOCATED NEARER THAN 6" TO SOIL SHALL BE PRESSURE TREATED WOOD. SEE NOTES FOR PRESSURE TREATED WOOD AND FASTENERS REQUIREMENTS ON THIS PAGE. 5. GYPSUM WALLBOARD SHALL NOT BE INSTALLED UNTIL WEATHER PROTECTION IS INSTALLED. 6. WHEN INSTALLED DIRECTLY ON FRAMING, ALL EDGES AND ENDS OF GYPSUM WALLBOARD SHALL OCCUR ON THE FRAMING MEMBERS, EXCEPT THOSE EDGES WHICH ARE PERPENDICULAR TO THE FRAMING. 7. ALL FLOORING MATERIAL (CARPET, TILE, VINYL), WALL TILE, AND PAINT FINISHES SHALL BE SELECTED BY HOME OWNER. CONTRACTOR SHALL COORDINATE SELECTION OF THESE ITEMS WITH HOME OWNER. HAZARDS (GUARDRAILS & SAFETY GLAZING) 1. GUARDRAILS SHALL BE NO LESS THAN 36 INCHES IN HEIGHT. INTERMEDIATE RAILINGS ARE REQUIRED AND ARE TO BE ARRANGED SO THAT A 4-INCH SPHERE CANNOT PASS THROUGH. 2. SAFETY GLAZING IS REQUIRED IN ALL DOORS, RAILINGS, AND TUB OR SHOWER ENCLOSURES. ANY GLAZING WITHIN A DOOR OPENING AND WITHIN 60 INCHES OF THE FLOOR SHALL BE SAFETY GLAZING. FIXED GLAZING GREATER THAN 9 SQUARE FEET IN AREA AND WITHIN 18 INCHES OF THE FLOOR IS TO BE SAFETY GLAZING. REFER TO 2018 INTERNATIONAL RESIDENTIAL BUILDING CODE FOR ADDITIONAL AREAS OF SAFETY GLAZING. INDOOR AIR QUALITY NOTES 1. SOURCE SPECIFIC VENTILATION: SOURCE SPECIFIC EXHAUST VENTILATION SHALL BE REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, AND OTHER ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR IS PRODUCED. BATHROOM EXHAUST FANS AT 75 CFM, KITCHEN EXHAUST FANS AT 100 CFM. LAUNDRY EXHAUST FANS AT 100 CFM. 2. A WHOLE HOUSE FAN W/ TIMER (100 CFM MIN., 1.5 SOMES) WILL BE LOCATED IN THE LAUNDRY ROOM AT THE SECOND FLOOR. 3. VENTILATION DUCTS: ALL DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. 1. ALL PAINT AND LIKE FINISHES SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT ALL LOCATIONS WHERE CARPET AND RESILIENT FLOORING MEET. PROVIDE COLOR SAMPLES TO OWNER FOR APPROVAL. 3. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURERS RECOMMENDATIONS TO PROVIDE LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS. 4. ALL FLOORING MATERIALS TO BE LIGHT WEIGHT. CERAMIC TILE SHALL BE THIN -SET TYPE. CASEWORK & MILLWORK CONTRACTOR NOTE: THE FLOOR PLANS SHOW KITCHEN AND BATH CABINETS IN FLOOR PLANS ONLY. CONTRACTOR SHALL COORDINATE SELECTION OF CABINET MANUFACTURER AND TYPE WITH HOME OWNER. 1. ALL MILLWORK (WOODWORK AND CABINETRY) SPECIFIED ON THESE DRAWINGS SHALL BE FURNISHED AND INSTALLED BY THE MILLWORK CONTRACTOR UNLESS NOTED OTHERWISE. 2. THE MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FINISHES FOR ALL MILLWORK IN HIS SHOP. DO NOT APPLY FINISH COATS IN FIELD. 3. ALL MATERIALS AND WORKMANSHIP MUST BE EQUAL IN ALL RESPECTS TO THE STANDARDS SET FORTH IN THE ARCHITECTURAL WOODWORKING INSTITUTE (A.W.I.). MOST CURRENT EDITION PUBLISHED BY THE A.W.I. AND THE STANDARDS SET BY THE OWNER / CONTRACTOR. 4. PLYWOOD SHALL PER THE GRADE AND TRADEMARK IDENTIFICATION OF THE AMERICAN PLYWOOD ASSOCIATION (APA). 5. PARTICLEBOARD BACKING SHALL BE PERMITTED IN AREAS OF THE CASEWORK THAT ARE NOT VISIBLE. 6. PROVIDE CUT-OUTS IN MILLWORK AS REQUIRED FOR ALL ELECTRICAL ITEMS. VERIFY ALL REQUIREMENTS PRIOR TO FABRICATION. 7. FIT AND SECURE CABINET HARDWARE PER MANUFACTURER'S PRINTED INSTRUCTIONS. EXERCISE CAUTION NOT TO INJURE OR MAR SURFACES. REPAIR ANY AND ALL DAMAGED SURFACES TO LIKE -NEW CONDITION. 8. ALL MILLWORK ELECTRICAL MATERIAL, WORKMANSHIP, AND INSTALLATIONS SHALL BE IN CONFORMANCE WITH APPLICABLE LOCAL, STATE, AND NATIONAL ORDINANCES AND CODES. ALL MATERIAL AND FIXTURES TO BE U.L. APPROVED. 9. THE GENERAL CONTRACTOR SHALL FURNISH ALL NECESSARY WOOD BLOCKING FOR A COMPLETE AND SECURE INSTALLATION. WATERPROOFING CONSTRUCTION NOTES THIS ENTIRE SET OF ARCHITECTURAL DRAWINGS IS PREPARED AS A PERMIT SET OF DRAWINGS ONLY FOR THE OWNER AND BUILDER FOR THIS PROJECT ONLY. ALL DETAILS AND DRAWINGS SHOWN ARE FOR PERMIT PURPOSES ONLY AND DO NOT CONSTITUTE THE FULL SET OF DETAILS REQUIRED TO CONSTRUCT THIS PROJECT. THE BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHERTIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING, AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE BUILDER, AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS, AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. PER WASHINGTON STATE LAW, THE TOWNHOUSE UNITS REQUIRE THE DESIGN AND INSPECTION SERVICES OF A BUILDING ENCLOSURE DESIGNER TO DESIGN ALL FLASHING AND WATERPROOFING DETAILS AND INSPECTION OF THESE ITEMS. CONTRACTOR SHALL COORDINATE ALL TOWNHOUSE BUILDING ENCLOSURE DETAILS WITH BUILDING ENCLOSURE DESIGN FIRM. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A WEATHERTIGHT BUILDING INCLUDING ALL NECESSARY SEALANT AND FLASHINGS IN ACCORDANCE WITH INDUSTRY STANDARDS, WHETHER DETAILED SPECIFICALLY IN THESE DRAWINGS OR NOT. 1. EXTERIOR DOORS, WINDOWS, VENTS, CORRIDOR OPENINGS: THE CONTRACTOR SHALL SEAL AROUND ALL EXTERIOR WINDOWS, DOORS, VENTS AND OTHER SUCH PENETRATIONS WITH A CONTINUOUS BEAD OF CAULKING TO PROVIDE FOR A WEATHER -TIGHT STRUCTURE. IN ADDITION, ALL EXTERIOR OPENINGS (WINDOWS, DOORS, VENTS, CORRIDOR OPENINGS) SHALL BE FLASHED WITH A FLASHING MEMBRANE AS SHOWN ON THE WINDOW DETAIL SHEET. USE METAL HEAD FLASHING ABOVE ALL EXTERIOR DOORS AND WINDOWS. FURNISH AND INSTALL FLASHINGS IN ACCORDANCE WITH SMACNA STANDARDS. 2. SEE SHEET A-4.1 CONSTRUCTION ASSEMBLY NOTES FOR INFORMATION ON BASEMENT WALL WATERPROOFING. PRESSURE TREATED WOOD / STRUCTURAL FASTENERS EFFECTIVE DEC. 31, 2003, THE PRESSURE TREATED WOOD INDUSTRY VOLUNTARILY TRANSITIONED FROM CHROMATED COPPER ARSENATE (CCA-C) USED IN RESIDENTIAL CONSTRUCTION TO ALTERNATIVE TREATMENTS. ANY PRESSURE TREATED WOOD SPECIFIED FOR THIS PROJECT SHALL NOT CONTAIN CCA-C IN THE PRESERVATIVE PROCESS. ACCORDING TO SIMPSON STRONGTIES WEBSITE, "TESTING HAS SHOWN THAT CERTAIN REPLACEMENT ALTERNATIVE TREATMENTS ARE GENERALLY MORE CORROSIVE THAN CCA-C". AS A RESULT OF THESE ALTERNATIVE METHODS OF TREATMENT, THE NON CCA-C TREATED WOOD IS MORE CORROSIVE TO METAL HANGERS AND FASTENERS. REFER TO SIMPSON STRUCTURAL HANGERS WEBSITE FOR TECHNICAL BULLETIN. (wwwSTRONGTIE.COM (SIMPSON'S WEBSITE), GO TO "CORROSION INFORMATION" THEN "PRESSURE TREATED WOOD TECH BULLETIN".) . REFER TO SIMPSON'S WEBPAGE "wwwSTRONGTIE.COM/PRODUCTUSE/SELECTION-GUIDE.HTML" FOR PRODUCT USE SELECTION GUIDE. REFER TO SIMPSONS WEBSITE FOR REQUIREMENTS FOR NAILS, BOLTS, AND HANGERS USED WITH PRESSURE TREATED WOOD. STANDARD HOT DIPPED GALVANIZED FASTERNERS, BOLTS, AND NAILS MAY NOT ACCEPTABLE WITH THE NEW TYPES OF PRESSURE TREATED WOODS (ACCORDING TO SIMPSON'S WEBSITE TECHNICAL PUBLICATIONS.). BUILDER / DEVELOPER SHALL BE RESPONSIBLE FOR VERIFYING WHICH FASTENERS ARE ACCEPTABLE FOR USE AND SHALL TAKE LIABILITY FOR PERFORMANCE OF FASTENERS OR CONNECTORS SELECTED AND USED ON THIS PROJECT. ANY REFERENCES ON STRUCTURAL DRAWINGS FOR THIS PROJECT TO PRESSURE TREATED WOOD SHALL DEFER TO THE REQUIREMENTS LISTED ABOVE. MOLD CONTROL PROPER STORAGE AND HANDLING OF BUILDING PRODUCTS HELPS PREVENT MOLD KEEP STOCKS OF LUMBER, PLYWOOD, ORIENTED -STRAND BOARD (OSB), DRYWALL, AND OTHER POROUS MATERIALS IN A DRY, COVERED STORAGE AREA. IF THE STOCKPILES ARE OUT IN THE OPEN, AND IT LOOKS LIKE IT MIGHT RAIN, COVER THE MATERIALS WITH A GOOD TARP, ANCHORED DOWN SO THAT THE WIND DOES NOT BLOW IT OFF. WHEN THE MATERIALS ARE NEEDED, REMOVE THEM FROM BENEATH THE COVER WITHOUT ALLOWING THE REMAINDER TO GET WET OR DAMP.BEFORE INSTALLING THE MATERIALS, INSPECT CAREFULLY FOR WATER DAMAGE, STAINING, WARPING, OR INITIAL SIGNS OF MOLD GROWTH. SUCH SIGNS MIGHT BE VISIBLE PATCHES OF MOLD, OR MUSTY ODORS ASSOCIATED WITH MOLD OR MILDEW. DISCARD ANY SUCH MATERIALS IMMEDIATELY. INSTALL A ROOF OR COVER THE NEW CONSTRUCTION AS SOON AS PRACTICAL. DRYING WOOD CONSTRUCTION PRIOR TO INSULATION OR DRYWALL INSTALLATION WHEN THE BUILDING FRAME IS COMPLET AND EXTERIOR SIDING IS INSTALLED, CONTRACTOR SHALL USE A PIN -TYPE MOISTURE METER TO VERIFY MOISTURE CONTENT IN WOOD FRAMING, FLOOR SHEATHING, WALL SHEATHING, AND ROOF SHEATHING. MOISTURE CONTENT OF ALL WOOD MEMBERS AND SHEATHING SHALL BE 15% OR LESS. IF THE MOISTURE CONTENT IS HIGHER, CONTRACTOR SHALL USE A COMBINATION OF HIGH VOLUME FANS AND DEHUMIDIFIERS TO THOROUGHLY DRY THE WOOD FRAMING AND SHEATHING PRIOR TO ANY INSTALLATION OF INSULATION OR DRYWALL. THIS SHOULD BE DONE TO HELP MINIMIZE ANY MOISTURE DAMAGE TO INTERIOR OF WOOD FRAMING SURFACES OR SHEATHING. RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson -Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Project Client & Project Applicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 ChaPt Title General Notes 7543 7REGISTERED ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description I�3ffi:\►AYI_WK011M1W161010[W.AlIIto) 01 This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 04/17/13 A-1,02 Drawn By Author General Notes Scale 12" = V-0" Sheet Plot Date 7/17/2023 1:49:46 PM www.CarIColsonArchitect.com ilia 1 1 i 5'-0" I I i i i EXTERIOR HEATED LIVING SPACE F I 7'- 1 1 /8" LEVEL 1 : ELEV. 0'- 0" TOP OF PLYWOOD If TOP OF CONC. WALL: N ELEV. (-) 0'-2 3/8" 1 � I 1 BURIED CORRUGATED LNo VENT WELL (20" WIDE x d 8" WIDE x 12" HIGH) PROPERTY LINE IT I 1 1\ 4' I 1 a O O I 0 co CONC. FOUNDATION WALL PER STRUCTURAL DRAWINGS 1 8" HIGH x 16" WIDE SCREENED 1 FOUNDATION VENT =' VENTED CRAWL SPACE ° I WATERPROOFING AT FOUNDATION d a I WALLS (TYP) I° a 1 FOUNDATION VENTS 0 WALLS 0 CRAWL SPACE BELOW LIVING AREA 1 EXTERIOR HEATED LIVING SPACE RIPPED PRESSURE TREATED ANCHOR PLATE 1 i TO EXTEND FULL WIDTH OF FOUNDATION 1 0o WALL. BRUSH PRESERVATIVE SEALANT ON co i SIDES AND ENDS OF CUT ANCHOR PLATE i LEVEL 1 : ELEV. 0'- 0" TOP OF 7/8" THICK ADVANTECH FLOOR CONCRETE @ ENTRY PORCH SHEATHING 1 & REAR PATIO % TOP OF CONC. WALL: 1 1 N ELEV. (-) 0'-2 3/8" I `O I o 3 — — 4 e I INSTALL NERVESTRAL WEATHER RESISTIVE BARRIER BETWEEN JOIST a I HANGER AND FOUNDATION WALL TOP o°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oboo ° PLATE PRIOR TO HANGING JOISTS- CPoCPoCPoCPoCPoCPoCPoCPoCPoCPoCPoCPoCPoCPoCP I O O boo°oo°oa°oa°oa°oo°oo°oo°Oo°Oo°oo°oo°oo°oo°oo d°° - a - oOoOCPoCPoCPoCPoo.0o.0o.0o.0o.0o.0o.0o Pone d, boo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo°oo ° I JOIST HANGERS HUNG FROM ANCHOR PLATE PER STRUCT. DWGS. 1 ° CONC. FOUNDATION WALL PER 1 d4ID. a . STRUCTURAL DRAWINGS WATERPROOFING AT FOUNDATION WALLS (TYP) d I VENTED CRAWL SPACE 1 � FOUNDATION WALLS (a RAWL SPACE BELOW LIVING AREA I IT I I I i � 1 1 TYPICAL EXTERIOR WALL CONSTRUCTION. SEE SHEET A-4.1 FOR NOTES I I i EXTERIOR i GARAGE I 1 CONIC FOUNDATION WALL PER 1 I STRUCTURAL DRAWINGS TOP OF CONC. WALL: ELEV. (-) I I CONC. GARAGE SLAB J d d a _ d II ° d ad 1 1 FOUNDATION WALLS 0 EXTERIOR GARAGE WALLS Foundation Wall Details 20 1 2 1 " = 1 '— " 1 / � 1 I CRAWL SPACE VENTING CALCULATIONS REFER TO BUILDING ELEVATIONS FOR LOCATION OF CRAWL SPACE VENTS. VENTS SHALL BE 8" X 16". VENTS TO BE INSTALLED IN CONCRETE FOUNDATION WALL AND SHALL HAVE GALVANIZED STEEL VENT WELLS INSTALLED IN FINISH GRADE / TOPSOIL. HEATED LIVING AREA @ LEVEL 1 (OVER CRAWL SPACE) 1546 S.F. 1 S.F. OF VENT AREA PER 300 S.F. OF FLOOR AREA (1546 DIV. BY 300) = 5.16 S.F. VENT SIZE 8"x16" (.75 S.F. FREE AREA PER VENT) NUMBER OF VENTS REQUIRED (5.15 DIVIDED BY .75 = 6.88) 7 VENTS MIN. REQUIRED (SEE EXTERIOR ELEVATION SHEETS & ARCHITECTURAL FOUNDATION PLAN FOR LOCATION OF CRAWL SPACE VENTS) Crawl Space Vent Calculations 4 ii„ = ;1_0111 LOCATION OF PORCH COLUMNS. SEE LEVEL 1 FLOOR PLAN FOR LOCATION DIMENSIONS OF COLUMNS. SEE STRUCTURAL DRAWINGS FOR SIZE OF SUPPORT POST & CONCRETE FOOTING (TYP) 17'-8" 17'-4" F ° FOUNDATION VENT SHADED AREAS (wl DASHED LINES) INDICATE LOCATION OF 0o WALLS AT LEVEL 1 ABOVE (TYP) --FOUND. VENT 10' -"1 " 4" ie - 91-5 I , 0 CONCRETE PORCH SLAB r 44 _d OPENING FO U \,�_ENTRY DOOR - - CONCRETE DRIVEWAY & WALKWAY SLAB - THIS LINE INDICATES - - , - LOCATION OF BUILDING SETBACK LINES 61'-0" - 1 11'-11" _ 22'-0"' I 6'-91/8" I 4" 11'- 7" - - - ofv i0 FOUND. o---------'—_------- CV r 6- 10" 6- 1 _—�-/\IOPENING FOR GARAGE DOOR' , R BUILDER NOTE: FLOOR JOISTS DO NOT SIT ON EXTERIOR I FOUNDATION WALLS (TYPICAL) - - - - SEE DETAIL #2 ON THIS PAGE THEY ARE HUNG FROM THE SIDE FOR CONCRETE PORCH SLAB ELEVATION NEXT TO OF WALL wI JOIST HANGERS. REFER TO STRUCTURAL DRAWINGS 1 - FRAMING LAYOUT / BEAMS / SUPPORT POSTS / FOOTINGS: _I THIS DRAWING DOES NOT SHOW LEVEL 1 FLOOR FRAMING, HOUSE (TYP) 1 CONCRETE GARAGE SLAB I SLOPE SLAB 4"TO BEAM SUPPORT POSTS OR FOOTINGS. 0 N I - - GARAGE DOOR SEE STRUCTURAL DRAWINGS FOR ADDITIONAL F r I — INFORMATION 1- CJ IT VENTED CRAWL LO SPACE TYP --BUILDER NOTE: FLOOR JOISTS DO NOT SIT ON EXTERIOR FOUNDATION WALLS (TYPICAL) - THEY ARE HUNG I r FROM THE SIDE OF WALL wl JOIST I LO I CRAWL SPACE M I I > - I HANGERS. N I II ACCESS HATCH `� � � I I I � ' \ OPENING FOR z , REFER TO STRUCTURAL DRAWINGS I L -------J I I I I - '' GARAGE ENTRY DOOR FOUND. VENT L — _ _ — J — _ _ -- JJ OPENING FOR LOCATION OF CRAWL SPACE ACCESS HATCH MUDROOM ENTRY I DASHED LINES INDICATE SUPPORT POSTS I FOOTINGS I BEAMS DOOR I CONCRETE CRACK CONTROL, SEE STRUCTURAL DRAWINGS FOR SHADED AREAS (wl DASHED JOINTS IN CONCRETE GARAGE LOCATIONS OF ALL SUPPORT POSTS & FOOTINGS FOR FLOOR FRAMING BEAMS. LINES) INDICATE LOCATION OF I SLAB (TYP) ° WALLS AT LEVEL 1 ABOVE (TYP)>I CJ SEE STRUCTURAL DRAWINGS FOR SIZE OF SUPPORT POST &CONCRETE Fr — — — — — I — a FOOTING (TYP) I I - I SHADED CONCRETE SLAB > I 5' - 11 1 /2" I AREA SHALL BE LEVEL (TYP) \ 21 ' - 11 1 /2" 9'- 7 1 /2" I 7'- 5" 5'- 11 1 /2" 116' - 0 1 /2" 01 SEE BUILDING SECTION FOR SEE DETAIL #2 ON -THIS PAGE C� ; INFORMATION ON r 7 FOR_ CONCRETE PORCH WATERPROOFING @ F_ SLAB ELEVATION NEXT TO, _ U k ; EXTERIOR FACE OF ° T HOUSE (TYP)> Io I FOUNDATION WALLS (TYP) OPENING FOR FOUND. VENT DASHED LINES INDICATE FOUND. I PATIO / PORCH CONCRETE CRACK CONTROL VENT I DOORS JOINTS IN CONCRETE PORCH , SLAB (TYP) ° CJ - - T 7' - 5" 14' - 6 1 /2" - 4' 5" 3' _ 21 ` - 11 1 /2" T _ 5" 1 - > ' 9''- 7 1 /2" 9' - 7 1 /2" 12' - 4 1 /2" _ CONCRETE PORCH SLAB N r r N FOUND. I CONCRETE r (O � r N VENT , GARAGE SLAB 10 3 1 /2" 9' - 7 1 /2" 1' % 5" in N — — rV7-- CJ .00 ------ 39'-0" - 9'-71/2" - I 121-414' LOCATION OF FULL HEIGHT PORCH COLUMNS WOOD POSTS OVER CONC. SONOTUBE COLUMNS OVER CONCRETE FOOTINGS. I DASHED LINES INDICATE SEE LEVEL 1 FLOOR PLAN FOR LOCATION — - —,� r CONCRETE CRACK CONTROL DIMENSIONS OF COLUMNS. I I I JOINTS IN CONCRETE GARAGE SEE STRUCTURAL DRAWINGS FOR SIZE OF N SUPPORT POST & CONCRETE FOOTING (TYP) -I _I I I 31 I , -SLAB(TYP)- �I - � o ' M L� SEE LEVEL 1 FLOOR PLAN FOR ALL EXTERIOR WALL M a - , - �I I � `f' & COLUMN / FOUNDATION LOCATIONS (TYP) SHADED_CONCRETE', I I> SEE STRUCTURAL DRAWINGS FOR ALL ELEVATIONS ° SLAB AREA SHALL BE , LEVEL (TYP) OF ALL CONCRETE WALL, FOOTINGS, FOUNDATIONS BUILDER NOTE: DOWNSPOUTS OPENING FOR OPENING FOR COORDINATE DOWNSPOUT LOCATIONS w/OWNER ADU ENTRY DOOR I - GARAGE DOOR - ' - - - - AND FOUNDATION SUBCONTRACTOR PRIOR TO - - INSTALLATION OF BELOW GRADE PERIMETER , — — — — — — — — — — DRAIN LINES AND INSTALLATION OF r 1' O" 6' - 0," 15' - 0" oe ■ _ 1 DOWNSPOUTS @ UPPER AND LOWER ROOFS r North Architectural Dimensions Foundation Plan SEE DETAIL #2 ON THIS P GE FOR CONCRETE DRIVEWAY & ONCRETE PORCH SLAB WALKWAY SLAB f�2Z- ELEVATION NEXT TO HOUSE (TYP) 1 /4�� = 1 1_011 oe 61'-0" CONTRACTOR NOTE: REFER TO STRUCTURAL DRAWINGS FOR ALL FOUNDATION WALL CONNECTIONS, REINFORCING, ANCHOR BOLTS, SEISIMIC CONNECTIONS AT ALL FOUNDATION WALLS (TYP) CONTRACTOR NOTE: THIS DRAWING IS NOT THE ONLY FOUNDATION PLAN. THIS PLAN WAS DONE TO SHOW DIMENSIONS FOR LAYOUT OF FOUNDATION PLAN. FRAMING LAYOUT / BEAMS / SUPPORT POSTS / FOOTINGS: THIS DRAWING DOES NOT SHOW LEVEL 1 FLOOR FRAMING, BEAM SUPPORT POSTS OR FOOTINGS. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION FRAMER NOTE: LEVEL 1 FLOOR JOISTS ARE TO BEAR ON TOP OF DROPPED SUPPORT BEAMS, UNLESS NOTED OTHERWISE. SEE STRUCTURAL DRAWINGS THIS LINE INDICATES LOCATION OF BUILDING SETBACK LINES 1 1 PROPERTY LINE 1 1 1 1 1 I 1 1 LO _ 3 LO 1 A-4.1 1 1 1 1 1 1 1 1 RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 6' - 9 1 /8" I Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarlColsonArchitect. com Commercial & Residential Architecture Tang Residence Pro-ject Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Foundation Plan For Dimension Layout 7543 REGISTERS ////✓n- /A{/RCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 11 17-18-2023 I PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 07/03/18 A-2,0 1 Drawn By Author Foundation Plan For Dimension Layout Scale As indicated Sheet Plot Date 7/17/2023 1:51:28 PM www.CarIColsonArchitect.com TANG RESIDENCE BUILDING AREA CALCULATIONS 1 1 NOTES TO LEVEL 1 FLOOR PLAN 20 FRONT BLDG. SETBACK TOILET CLEARANCES SHALL BE 15" FROM CENTER OF FIXTURE TO 5' SIDE BLDG. ADJACENT WALL OR COUNTERTOP. MIN. 30" CLEAR BETWEEN SIDE SETBACK OR END WALL AND COUNTERTOP WITH TOILET FIXTURE AT 1 6-5" MIDPOINT. 1 KITCHEN CABINETS AND COUNTER LAYOUTS BY OWNER 9 — — — — — — — SELECTED KITCHEN DESIGNER. KITCHEN PLAN SHOWN IS 1 SCHEMATIC ONLY. OWNER TO SELECT KITCHEN CABINETS STYLE, 1 LAYOUT, APPLIANCES, PLUMBING FIXTURES, AND COUNTERTOP r 1 11 MATERIALS 1 - 17'-8" 3'-5" 3'-5" 5'-5" 0 O 1 N N OI BUILT-IN r M LINE OF UPPER CABINETS ABOVE. SHELVES Lo BELOW SEE SHEET A 4.3 FOR WINDOW JAMB 3. BUILT-IN REFRIGERATOR W/ SIDE PANELS BY CABINET WINDOWS DETAIL @ DOUBLE OR TRIPLE WINDOWS (TYP) MANUFACTURER. 42" WIDE MODEL SHOWN, VERIFY WIDTH w/ OWNER SELECTED REFRIGERATOR. 1 4.) GAS RANGE / COOKTOP (SELECTION BY OWNER) W/ 8" DIA. 1 N r I 1 r&7' N r RIGID METAL / ALUMINUM EXHAUST VENT UP AND TO EXIT THRU N ",' ROOF ABOVE GARAGE STORAGE AREA. COORDINATE SELECTION & T I 1 L 10 Living T INSTALLATION W/ OWNER AND KITCHEN DESIGNER. COORDINATE EXHAUST VENT LOCATION W/ OWNER. I ADJUSTABLE SHELVING IN PANTRY HEIGHT, WIDTH, MATERIAL 1 16 1/2" AND NUMBER OF SHELVES TO BE SELECTED BY OWNER. I nl It LINE OF BEAM ABOVE. SEE STRUCT. - BUILT-IN r M DWGS. SHELVES Lo � CASED OPENING W/ TRIM TO ALIGN — KITCHEN ISLAND W/ VEGETABLE SINK AND CABINETS BELOW & N OI BELOW -1w/HEAD TRIM @DOORS (TYP) SPACE FOR SEATING AS SHOWN. WELDED STEEL PLATES TO r r wlNDows SUPPORT CANTILEVERED COUNTERTOP. COORDINATE THIS DETAIL in CO I 11 22 W/ CABINET SUPPLIER o 1 I - T 1 2' 2" 13'-4"01 ALL STAIR GUARDRAILS AND POSTS SHALL BE SELECTED BY OWNER. N AREA w/ DIAGONAL LINES IS Ln 34" HIGH WOOD RAILING (SEE GUARDRAIL NOTES ON SHEET A-4.1) NOg LOCATION OF CANTILEVERED Ln CD AT STAIRS TO UPPER LEVEL. I BATHROOM FLOOR ABOVE z 1 M Dinin ; CARPETED STAIRS W/ PAINTED OR STAINED WOOD STAIR I ' GUARDRAILS AND HANDRAILS. REFER TO STAIR NOTES ON SHEET J B 17 2 1/2 � A-4.1 FOR INFORMATION. STAIR MATERIAL SELECTION BY OWNER I i 17' - 2 1 /2" M LINE OF ROOF OVERHANG ABOVE. SEE ROOF PLAN FOR Q INFORMATION. J 10. MANUFACTURED GAS FIREPLACE (SELECTION BY OWNER). o INSTALL PER ALL APPLICABLE BUILDING AND SAFETY CODES. T 11 I FIREPLACE MANTLE SELECTION AND INSTALLATION HEIGHT TO BE 3 m N 1 BY OWNER. FIREPLACE TO BE VENTED THRU METAL FLUE THROUGH REAR EXTERIOR WALL.. INSTALL 5/8" TYPE "X" G.W.B. AT SIDES AND TOP OF FIREPLACE ENCLOSURE PER CODE. INSTALL BUILDING 1 DIRECT VENT MANUFACTURED GAS FIREPLACE IN ACCORDANCE SECTION j 1 W/ MANUFACTURER'S SPECIFICATIONS AND STATE CODES 2- U M. BUILT-IN SHELVES ADJACENT TO FIREPLACE. COORDINATE M TYPE OF SHELVES, NUMBER AND HEIGHTS OF SHELVES WITH HEAT IF KITC OWNER PUMP SEL SCH 1 STY 12. TILE FLOORING AT BATHROOM. SELECTION BY OWNER. I COU PROVIDE BLOCKING IN ALL BATHROOMS FOR TOWEL BARS & I TOILET PAPER HOLDERS. I M. QUARTZ COUNTERTOP & BACKSPLASH W/ UNDERMOUNT SINK 1 7'- 7 1 W/ MIRROR ABOVE AND WOOD CABINET BELOW AT ALL BATHROOMS (TYP). SINK, COUNTERTOP, CABINETS, MIRROR, AND PLUMBING FIXTURES SELECTION BY OWNER. I 9 401 14. ELECTRIC HYBRID HEAT PUMP WATER HEATER IN GARAGE. COORDINATE LOCATION OF HEATER W/ OWNER. VENT WATER HEATER TO EXTERIOR THROUGH MANUFACTURE APPROVED VENT PIPE. COORDINATE VENT PIPE LOCATION W/ OWNER. 1 I 15.) CONCRETE CRACK CONTROL JOINT IN SLAB. CONTRACTOR SHALL BE SAWCUT. INSTALL CONCRETE CONTROL JOINTS SO THAT MAX AREA OF SLAB WITHIN JOINT BOUNDARIES SHALL BE 120 S.F. MAX.. THESE JOINTS ARE TO BE INSTALLED TO MINIMIZE CRACKING OF CONCRETE SLABS. 1 16. LOCATION OF ELECTRIC METER / PANEL AND GAS METER. INSTALL PER SAFETY CODES AND REQUIREMENTS OF EACH UTILITY. COORDINATE METER LOCATIONS W/ OWNER. 17. SEE NOTES ON THIS SHEET FOR SEPARATION REQUIREMENTS (FOR WALLS AND DOORS) BETWEEN GARAGE / LIVING SPACE / ACCESSORY DWELLING UNIT 1 I 18. PORCH ROOF SUPPORT COLUMNS W/ WOOD WRAP - SEE COLUMN DETAIL ON SHEET A-3.1 M. LINE OF PORCH ROOF SUPPORT BEAM ABOVE - SEE STRUCTURAL DRAWINGS 1 I 20. CONCRETE WALKWAY / DRIVEWAY / GARAGE SLAB: (4" CONCRETE SLAB OVER COMPACTED GRAVEL BASE) W/ EXPANSION & CRACK CONTROL JOINTS. OWNER AND BUILDER SHALL COORDINATE FINISH TEXTURE OF PORCH, WALKWAY, AND DRIVEWAY CONCRETE SLABS 1 5' SIDE BLDG. 22.) TRIM CARPENTER NOTE: ALL CASED OPENINGS IN 2x6 WALLS I SETBACK SHALL BE TRIMMED W/ PAINTED MDF CASING & TRIM AT HEAD AND — JAMBS AS SELECTED BY OWNER (TYPICAL) 20' FRONT BLDG. SETBACK -0riveway Entry Walk 61'-0" - - 9,5" ill -ill, 22'-0" - 4'-1" 3'-5" 4'-5" ill -0" - - 11'-01, - 5SIDE 001 BLDG. SETBACK —18 — Plantin r - - ------ --------_-----t4vg�_ — —_ _ —Bed __-----_—_-- — 19 �p 1J 16' x 8' CARRIAGE STYLE GARAG DO w/ AUTOMATIC OPENERS — ---- --- - 1 Covered GARAGE SLAB - Entry Parch o0 0 0 (ELEV. 175.04) 1 I I' - - I 4' $ 1 /2" 4' . 8 1 /2" 0) k�= 1 Home Office I I 1 co r o CA 2868 A GLASST \ L - - - - - - - - - ' DOORS N II II10 9' - 10 1/2" Entry Vestibule = 7 III 8 HVAC CHASE UP ih 2" 5 -1 " 3'-8" 4'-8" 3 N M Mud Cn EQ 1 I 6-1- 24 2668 1 r122° x 4y, o�RAW� � 1 1 I SPA¢E ACOESSI I �EQ L MTV-J I I 5' -6" 4'-7" 22 5'-3" 5'-8" LJ II / BUILT-IN SHELVES OR 00 00 CABINETS (BELOW LANDING) FACING 5'- 1" MUDROOM 7' - 1 " 3' - 7 1/2" Ce) 7'- 8 1 � N T I' — ELEC. Ce)GJ MTR. 16 GAS - GARAGE SLAB 2 Car Garage AREA w/ DIAGONAL LINES 3080 (ELEV. 175.39) IS LOCATION OF - 1-3/8" THICK SOLID CORE\/??� �, - ' -CANTILEVERED - DOOR w/ WEATHERSTRIPPINGI BATHROOM FLOOR ABOVE t & SELF -CLOSING DEVICE 5'- 6 1/2" 4' I 11 ' - 8 1 /2" TRASH LC 15 LINE OF FLUSH 3 BEAM ABOVE. SE 13 St ra eL LEVEL 1 FLOOR STRUCT. DWGS. o� M 2668 (ELEV. 175.56) 1 Pam Pwdr.7 ECTED LE, 12 5 LINE OF FLUSH BEAM 2 1 1 _ ABOVE BELOW WALL C° 00 ABOVE. SEE STRUCT. 1 4 G M DWGS. Kitchen --- — ---- 6 7 Bedroom #4 4' - 9" - 6" 3' - 10" 1' - 10" 3' - 5 1/2" 13' - 5" HEN CABINETS AND COUNTER LAYOUTS BY OWNER r LINE OF PORCH ONE -HOUR RATED 2 x 4 4' - 3 1/2" KITCHEN DESIGNER. KITCHEN PLAN SHOWN IS I WALL ABOVE. SEE WALLS PER IRC R302.3.1 FOR EMATIC ONLY. OWNER TO SELECT KITCHEN CABINETS r I 5080 STRUCT. DWGS. WALLS SUPPORTING 1-HOUR LAYOUT, APPLIANCES, PLUMBING FIXTURES, AND NTERTOP MATERIALS �� 2-PANEL _ FLOOR ASSEMBLY ABO METAL ATED _ SLIDING FIRE OR w/ Dw - - - °' CLOSE & �o o o I GLASS Covered Porch_ O 12868 SECU TY LOCK ' -17 ■ 0 0 o O 7080 DOORS. - - /2 — - 20 131.4 sf 2' - 11 ", 6- 5 112" - -4' - 1'1 1 / ' -I 1 4' - 5" 3' 111 T r 5„ — I �21'-11 1%2" —--_—_—_— ,—_— - I'll 9'-71/2" P1' - 8" r 3 1/2" 9' - 7 1/2" 1 1 6, t O„ - co 20 cfl "3 Ji 1 19 19 1----- 1 1 Patio 18 11' - 4" 18 9 r �1 FIRE SEPARATION BETWEEN 10 r, RESIDENCE & ADU in N T1 BUILDER & CITY OF EDMONDS PLAN REVIEWER: 1 North SEE FIRE SEPARATION ASSEMBLY NOTES @ LOWER 16' 0" RIGHT OF THIS SHEET. A EE HEST ETAIL WIN NE H R S S -4FR D.3 0 SSH 0 GO OU RATED WALL ASSEMBLY DETAIL AND ONE HOUR RATED FLOOR / CEILING ASSEMBLY DETAIL. LEVEL 1 FLOOR PLAN PORTIONS OF LEVEL GARAGE SLABS GARAGE SLAB @ AREAS w/ DIAGONAL LINES ARE LEVEL 1 /411 = 1 -011 @ ELEV. 175.39 N N N C0 1-3/8" THICK SOLID CORE DOOR w/, SELF -CLOSING DEVICE 12 N - ' GARAGE SLAB - co N � TILE "(ELEV. 1"75.39)' , 13 SHOWER PROVIDE WATER SUPPLY IN ADU -H _ PAN `O GARAGE FOR FUTURE ON- o DEMAND WATER 0,HEATER. CO R$ AT /0 NE HEAT PUMP FOR ADU 777 -- — — — — — P 1 4 1 lo- L, SHADED AREA ; o .L -L IS ACCESSORY - CM DWELLING UNIT F -T — — — TRASHI -------=- - 1� _ 1 - N - A.D.U.. - RECY -EI o' -BI GARAGE SLAB 15 - - �I� (ELEV. 175.18) I '8' -_O' - 14'-0" - - 19 F 1 o'---CJ9 -------- 18 J M '— - - CJ 12',- 4 - 6 , 0 6' '0"15'=0""1 - - 2001 2�' - 0" - - I 6'- 9 1 /8" T CJ 6 SIDE 7- BLDG. SETBACK CONCRETE CONTROL JOINTS CONCRETE SUBCONTRACTOR SHALL VERIFY & INSTALL ALL CONCRETE CONTROL JOINT LOCATIONS IN DRIVEWAYS, WALKWAYS, AND GARAGE SLABS TO PREVENT RANDOM CRACKING OF CONCRETE SLABS 3 A-4.1 BUILDING SECTION I I ESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SINGLE FAMILY RESIDENCE LEVEL 1 FLOOR AREA (HEATED) 1546 s.f.. LEVEL 2 FLOOR AREA (HEATED) 1761 s.f. TOTAL FLOOR AREA (HEATED) 3307 s.f. GARAGE / STORAGE AREA 697 S.F. ENTRY PORCH 75 S.F. REAR PATIO/ PORCH 204 S.F. Carl J. Colson - Architect UPPER PORCH 153 S.F. PLLC ACCESSORY DWELLING UNIT (ADU LEVEL 1 FLOOR AREA (HEATED) 106 s.f. LEVEL 2 FLOOR AREA (HEATED) 611 s.f. TOTAL FLOOR AREA (HEATED) 717 s.f. GARAGE / STORAGE AREA 257 S.F. LOT SIZE FOOTPRINT: 8201 S.F. 35% COVERAGE MAX: 2870 S.F. LOT COVERAGE FOOTPRINT: 2868 S.F. COVERAGE: 34.97%. IMPERVIOUS AREA CALCULATIONS HOUSE & ADU = 3160 S.F. (INCLUDES ROOF OVERHANG & COVERED PORCHES) ENTRY DRIVEWAY = 477 S.F. ADU DRIVEWAY = 369 S.F. OPEN PATIO = 44 S.F. ENTRY WALKWAY = 74 S.F. (PAVED AREAS DO NOT INCLUDE PORTION OF PAVING COVERED BY ROOF OVERHANGS) TOTAL = 4124 S.F. (4124 DIVIDED BY 8120 = 50.78%) LANDSCAPE COVERAGE LANDSCAPED AREA 4077S.F. (4077 / 8201 = 49.7%) LANDSCAPE PERCENTAGE 49.7% TANG RESIDENCE & ADU FLOOR FINISH SCHEDULE (ALL MATERIALS & COLORS TO BE SELECTED BY OWNER) LEVEL 1: ENTRY, HALL, LIVING; WOOD LEVEL 1: KITCHEN, DINING, PANTRY, WOOD LEVEL 1: ENSUITE BEDROOM & CLOSET CARPET LEVEL 1: OFFICE, STORAGE: CARPET LEVEL 1: ALL BATHROOMS: TILE STAIRS TO ALL LEVELS: CARPET LEVEL 2: ALL ROOMS EXCEPT BATHROOM: CARPET LEVEL 2: BATHROOMS, LAUNDRY TILE LEVEL 2: PORCH FLUID APPLIED OR MEMBRANE WATERPROOFING AS SELECTED BY OWNER. TANG RESIDENCE & ADU WALL & CEILING FINISH SCHEDULE (ALL PAINT COLORS & SHEENS SELECTED BY OWNER. KITCHEN AND BATHROOMS SHALL HAVE TILE BACKSPLASH). LEVEL 1: ALL ROOMS: GYP. BD: LEVEL 4 FINISH (NO ORANGE PEEL TEXTURE) LEVEL 2: ALL ROOMS: GYP. BD: LEVEL 4 FINISH (NO ORANGE PEEL TEXTURE) GARAGE: GYP. BD: LEVEL 3 FINISH SHOWERS: AS SELECTED BY OWNER TUB / SHOWER: AS SELECTED BY OWNER COUNTERTOPS ALL COUNTERTOPS SHALL BE QUARTZ, EXCEPT FOR LAUNDRY ROOM COUNTERS. COORDINATE THIS MATERIAL SELECTION WITH OWNER OCCUPANCY SEPARATION BETWEEN GARAGE & MECHANICAL ROOM AND LIVING SPACE CEILINGS: 1 LAYER OF 5/8" TYPE X G.W.B. ON ALL TRUSSES AND TJI's (1 LAYER ON STICK FRAMING @ 16" O.C. OR LESS) WHERE HABITABLE SPACE IS ABOVE GARAGE. WALLS: 1 LAYER OF 1/2 G.W.B. ON COMMON WALLS TO ROOF SHEATHING / 1 LAYER ON WALLS TO SUPPORT PROTECTED CEILINGS POSTS AND BEAMS: 1 LAYER DOOR TO LIVING AREA: INSTALL 1-3/8" SOLID CORE WOOD DOOR WITH SELF CLOSER AND WEATHERSTRIPPING OCCUPANCY SEPARATION BETWEEN SINGLE FAMILY RESIDENCE & ACCESSORY DWELLING UNIT CEILINGS: SEE 1-HOUR FIRE RATED CEILING / FLOOR ASSEMBLY DETAIL ON SHEET A-4.3 WALLS: SEE 1-HOUR FIRE RATED WALL ASSEMBLY DETAIL ON SHEET A-4.3 FIRE SEPARATION BETWEEN RESIDENCE AND ACCESSORY DWELLING UNIT (SEE SHEET A-4.3 FOR ONE -HOUR FIRE RATED ASSEMBLY DETAILS DWELLING UNITS IN TWO-FAMILY DWELLINGS SHALL BE SEPARATED FROM EACH OTHER BY WALL AND FLOOR ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR FIRE - RESISTANCE RATING WHERE TESTED IN ACCORDANCE WITH ASTM El 19, UL 263 OR SECTION 703.3 OF THE INTERNATIONAL BUILDING CODE. FIRE RESISTANCE -RATED FLOOR/CEILING AND WALL ASSEMBLIES SHALL EXTEND TO AND BE TIGHT AGAINST THE EXTERIOR WALL, AND WALL ASSEMBLIE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OFTHE ROOF SHEATHING. 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Level 1 Floor Plan Drawings for Conditional Use Permit for ADU 4-19-2023 7543 REGISTERS /ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 11 17-18-2023 I PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson -Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 03/28/13 A-2,02 Drawn By Author Level 1 Floor Plan Scale AS indicated Sheet Plot Date 7/17/2023 1:51 :49 PM www.CarIColsonArchitect.com ■ 61'-0" AIR BARRIER / AIR INFILTRATION NOTES ALL AIR BARRIERS AND INSULATION INSTALLATIONS SHALL COMPLY WITH THE 3'- 3" 2018 WASHINGTON STATE ENERGY CODE PER TABLE R402.4.1.1 AIR BARRIER: CONTINUOUS AIR BARRIER SHALL BE INSTALLED IN THE BUILDING 5 ENVELOPE. BREAKS/JOINTS IN THE AIR BARRIER SHALL BE SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. O INSULATION SHALL BE INSTALLED PER MANUF. GUIDELINES. INFILTRATION: THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR DIFFERENTIAL EXPANSION AND CONTRACTION. THE FOLLOWING ' SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED "' WITH AN AIR BARRIER MATERIAL, SUITABLE FILM OR SOLID MATERIAL: 0 1) SPACE BETWEEN WINDOWS/DOOR JAMBS & FRAMING AND SKYLIGHTS & - N* FRAMING. Lo 10 T 2) DUCTS, SHAFTS, UTILITY PENETRATIONS & FLUE SHAFTS OPENING TO EXT. OR LO UNCONDITIONED SPACE. T 3) JUNCTIONS OF FOUNDATION & SILL PLATE & JUNCTION OF THE TOP PLATE & 0 TOP OF EXT. WALLS. 4) HVAC REGISTER BOOTS THAT PENETRATE BLDG. THERMAL ENVELOPE (SEAL TO SUBFLOOR/DRYWALL). _ 5) RECESSED LIGHT FIXTURES INSTALLED IN THE BLDG. THERMAL ENVELOPE SHALL BE AIR TIGHT, IC -RATED (SEALED TO THE DRYWALL).10 6) BETWEEN GARAGE AND CONDITIONED SPACES. 7) AIR BARRIER TO BE INSTALLED ON FIREPLACE WALLS - FIREPLACE TO HAVE F_ GASKETED DOORS. N I 13'-0" 4'-8" 4'-8" 12'-0" 4'-8" 2'-5" 2'-3" 4'-31/2" 3'-5" 4'-31/2" 2'-4" 2'-4" 3'-6" ee Ile 3'-3" 3'-3" 3'-3" 6'-2" LI -6 - - - 5 I O O Master Bedroom #1 0 0 I FRAMER NOTE / WINDOW HEAD HEIGHT N T Bedroom #2 �, N I ALL WINDOWS AT LEVEL 2 TO HAVE A HEAD r rn HEIGHT OF 6' 10 -1/2" SO THAT TOP OF - WINDOW TRIM ALIGNS w/ TOP OF DOOR TRIM rn L - - J L - 1 J FRAMER NOTE: ALL PLYWOOD SUBFLOOR IS TO BE ADHERED TO JOISTS W/ SUBFLOOR ADHESIVE AND SCREWS PER STRUCTURAL DRAWINGS (TYP) 0 I SHADED WALLS INDICATE 2 x 6 STUD WALLS (TYP) 11'-5" 5'-91/2" 5'-7" SCISSOR TRUSS @ MASTER FURR BATHROOM BEDROOM CEILING (TYP) CEILING @THIS AREA BELOW SCISSOR N 3'- 11 " TRUSSES ABOVE T BATHROOM, SO AT BATHROOM C LING IS 8) OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH THE ROOF, r O° 2868 WALLS, AND FLOORS I CENTER TUB ' FLAT 9) BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS r ICE BETWEEN `� 10) JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDERS "I I WALL WINDOWS 12 11) ALL OTHER OPENINGS IN THE BUILDING ENVELOPE I SPOUT 13' - 0 1/2"r-------1 I o o r I AFETY 1 SKYLIGHT 1 WALL CORNERS & HDRS. SHALL BE INSULATED & SHALL BE SEALED. FLOORS, I I INCLUDING ABOVE GARAGE AND CANTILEVERED FLOORS - INSUL. SHALL BE co °' °' "' GLAZING @ L_______J INSTALLED TO MAINTAIN PERMANENT CONTACT W/ UNDERSIDE OF SUBFLOOR I WINDOWS Master Bathroom DECKING. THE AIR BARRIER SHALL BE INSTALLED AT ANY EXPOSED EDGE OF N I E INSUL. RIM JOIST SHALL BE INSULATED & INCLUDE AIR BARRIER. T I 13 14 CEILING/ATTIC - AIR BARRIER @ DROPPED CEILING/SOFFIT SHALL BE ALIGNED W/ N THE INSUL. AND ANY GAPS IN AIR BARRIER SEALED. ACCESS OPENINGS, DROP- I TILE DOWN STAIR, ETC. INTO UNCONDITIONED ATTIC SPACE SHALL BE SEALED. BATT T -I SHOWER; PAN, --- INSUL. INSTALLED IN ATTIC ROOF ASSEMBLIES MAY BE COMPRESSED @ EXT. WALL, LINES TO ALLOW FOR REQ'D ATTIC VENTILATION. BATT INSULATION. SHALL BE CUT NEATLY TO FIT AROUND WIRING & PLUMBING IN EXT. WALLS WITHOUT VOIDS/GAPS. AIR BARRIER SHALL EXTEND BEHIND 3 ELECTRICAL/COMMUNICATION BOXES OR INSTALL AIR SEALED BOXES. A-4.1 r o �, 5'- 5 1/2" EXTERIOR WALLS ADJACENT TO TUBS/SHOWERS TO BE INSULATED AND AIR BUILDINGCDSECTION T 0 BARRIER SHALL SEPARATE THE INSULATED WALL FROM THE SHOWER/TUB. In TIPS FOR AIR SEALING THE BUILDING ENVELOPE Seal corner studs on exterior and interior walls M Caulk drywall to top and bottom plates Seal vents and fans at penetration 0 Seal all penetrations Vapor retarder (If appropriate. Check local code requirements.) /- / Seal windows and doors into rough 6 openings Lap exterior+ / sheathing panels over intersections between - For Rim Boards, \.. exterior band joists and plates and/or walls, seal seal at panel at top and joints and - ® bottom around plates edges. and/or extend exterior Seal house sheathing wrap or over joints building paper Seal plumbing penetrations between to top and framing bottom plate - sections Seal exterior penetrr Caulk between Rim Boards, band joists and plates Seal ductwork with mastic Seal registers and HVAC penetrations AIR SEALING OPTION COORDINATE THIS ITEM w/ OWNER. PRIOR TO INSULATION, INSTALL AERO-BARRIER AIR SEALING SPRAY TO SEAL ALL AIR LEAKS 5 O 5' 11 1/2" '. Familv Room SHADED WALLS INDICATE 2 x 6 STUD WALLS (TYP). USE DOOR FRAMES FOR 2 x 6 WALLS @ 2 x 6 WALL LOCATIONS (TYP) WETBAR W/ SINK. COORDINATE W/ OWNER BIRD BLOCK EAVES BIRDBLOCKSAT ALL EAVES - IUI IDI 3'-8" 3'-5" 3'-5" 14'-2" Tan Residence Window Schedule QTY U-VALU TAG ID WIDTH HEIGHT AREA TYPE GLAZING E COMMENTS A 14 3' - 0" 5' - 0" 210 SF Single Hung Low E 0.28 With Grids - See Window Legend B 8 3' - 0" 5' - 0" 5' - 0" 120 SF Single Hung Single Hung Low E Low E 0.28 No Grids With Grids - See Window Legend No Grids C 2 2' - 8" 27 SF 0.28 D 9 T - 0" 4' - 0" 108 SF Single Hung Low E 0.28 E 3 2' - 8" 4' - 0" 32 SF Single Hung Low E 0.28 No Grids F 2 2' - 6" 4' - 0" 20 SF Single Hung Low E 0.28 With Grids - See Window Legend G 3 2' - 6" 4' - 0" 30 SF Single Hung Low E 0.28 No Grids H 5 T - 0" T - 6" 53 SF Single Hung Low E 0.28 No Grids 1 4 2' - 8" T - 6" 37 SF Single Hung Low E 0.28 With Grids - See Window Legend J 1 2' - 8" 3' - 6" 9 SF Single Hung Low E 0.28 No Grids K 3 2' - 4" 3' - 6" 25 SF Single Hung Low E 0.28 No Grids L 2 2' - 4" 3' - 0" 14 SF Single Hung Low E 0.28 No Grids M 2 1' - 6" 7' - 10" 24 SF Sidelights by Simpson Low E 0.28 By Simpson to match Entry door N 6 2' - 0" T - 0" 36 SF Skylight Grand total 744 SF N FRAMER & TRIM CARPENTER NOTE: SEE STAIR c? INFORMATION ON SHEET A-4.1 . Zo STAIRWELL TREADS, RISERS, & RAILING / NEWEL POSTS SELECTION BY OWNER N 9' 7" M ro 232� O I 11'-0" 11'-0" 4'-10" 2'-8" 3'-91/2" 3'-5" 4'-10" 6'- 7 1/2" 2668 6'- 2" UND BATT N INSULATION @ MECH. ic) r - ROOM WALLS TYP 0 r 0 1 11 \owwwn 5'_ 11 11/2" 4' - 4 1 /2" ------ 6' 8" - 8" 6'- 7 1/2" - 11 " HATCH T M F- -1 8 T 1 F- MECH SOLID CORE DOOR IDN I = @MECH ROOM ,,, �> J on h W m 1= ao C E00 Q o EQ SKYLIGHT Master U' ¢ M ABOVE L Closet _ � L - J - L - � w I I 8 - 8 CUT OFF BOTTOM OF 1 36" HIGH HALF r DOOR 3" FOR MAKEUP 25 N 00 � o WALL OR OPEN AIR TO ENTER � {� 3' - 9 1/2" 0 0 SEE SHEET A-4.3 FOR WINDOW JAMB DETAIL @ DOUBLE OR TRIPLE WINDOWS (TYP) Bedroom #3 BUILDER NOTE: INSTALL R-38 BATT INSULATION @ ALL FLOOR AREAS ABOVE GARAGE (TYP) 0 \I �1 Moil I s®_ FA _ 2868 r 9 1/2" �t N C) 9' - 0" 23 I DRYER L -1 r co io 0 M 12' - 9 1/2" -AB SH AN 32" x " 4'- 5 1/2" 2' $ 3' _ 7" SAFETY GLAZING @ DOOR 1 � WASHE M OL Laundry OL SINK t ao CUT OFF BOTTOM o M L -1 OF DOOR 3" FOR zi MAKEUP AIR TO N K fiHIS END OF ; I T- ENTER LAUNDR STACK 0 M w o I �. 18 �,- DECK 2" BELOW . - , �,. T w I o - N I WASHER / DRYER 2 SKYLIGHT FINISH FLOOR OF T \ r` N O v i:n ABOVE LIVINGAREA Lo J _; I U I O I I -, Covered b) S' I I T - Porch I � 17 22 (ROOF BELO - - BEAMS ABOVE 4' 0 14- 1 4' 0" ROOF BELOW 36" HIGH 2 x'6 WALLw/ I WALL BELOV o 11 - 9 1/2" I ; SLOPED CAP PIECE I a Kitchen WALL 36' NIGH OPEN_ , - a BELOW RAILINGS rn 3'-8" 3'-6" 4'-0' 11'=4" 6'-0" a° N N Bedroom COB N ATTIC ACCESS HATCH FOR ADU 1/ ' 11'-4" _ SEPARATION WALLS: DARK SHADED WALLS - 6 8 T INDICATE ONE -HOUR FIRE RATED SEPARATION WALLS w/ 2 x 6 STUD BETWEEN RESIDENCE & A.D.U. (TYP). HEIGHT OF SEPARATION WALLS B L ONE HOUR RATED STUD WALLS (AT UPPER _ LE L) BETWEEN RESIDENCE AND ACCESSORY cyo) DWE LING UNIT SHALL EXTEND TO UNDERSIDE OF SHEATHING. SEE SHEET A-4.3 FOR DETAILS N T REFS 00 c N 3' - 9" 102 1/2" 10' - 2 1/2" Home O Office ��[ DN ` ADU 11 SHADED FLOOR AREA ILLUSTRATES AREA OF WRAPPED BEAM ABOVE. SEE 36" HIGH OPEN RAILING OR ACCESSORY SMOKE DETECTORS & ELECT. SWITCHES / OUTLETS STRUCT. DWGS FOR BEAM DWELLING UNIT REFER TO SHEET A-2.5 FOR ALL SMOKE & CARBON SIZES (TYP) - HALF WALL 0"> MONOXIDE DETECTORS, ELECTRICAL FIXTURES, EXHAUST o '� T FAN AND SWITCHES REFER TO ROOF PLAN FOR 10 N p �, Dining Living N_ 19 20 / N 38"HIGH HALF WALL i4 20 LINE OF 21 CAI ROOF -------------- rE T 1 ABOVE 12' - 6" 6 - 6 1/2" co 6' 8" DN ih 17'-8" 21'-4" GUTTERS @ LOWER ROOF NOTES TO LEVEL 2 FLOOR PLAN SHADED AREA @ PERIMETER OF LOWER ROOF INDICATES LOCATION TOILET CLEARANCES SHALL BE 15" FROM CENTER OF GUTTERS (TYP) OF FIXTURE TO ADJACENT WALL OR REFER TO ROOF PLAN FOR COUNTERTOP. MIN. 30" CLEAR BETWEEN SIDE OR NOTES ON ROOF CONSTRUCTION END WALL AND COUNTERTOP WITH TOILET & FLASHING (TYP) FIXTURE AT MIDPOINT. 5 �r M coN IN I� - co r N IN r co vc r 0 ao r M �N d w Lr) cliT N T C r N _ N r CD r 6 T NOTES ON ROOF CONSTRUCTION N r co DOOR & WINDOW INFORMATION & FLASHING (TYP) FRAMER NOTE 1 WINDOW HEAD HEIGHT ALL WINDOWS AT LEVEL HAVE A HEAD REFER TO SHEET A-5.1 FOR ALL DOOR & WINDOW TYPES & GUTTERS @ LOWER ROOF HEIGHT OF 6' 10 -1/2" SO THHATAT TOP OF O - SIZES. FRAMER NOTE: DOOR & WINDOW HEAD HEIGHTS @ LEVEL 2 SHADED AREA @PERIMETER OF LOWER ROOF INDICATES WINDOW TRIM ALIGNS w/ TOP OF DOOR TRIM r r 0 O co ALL WINDOWS AT UPPER LEVEL TO HAVE A HEAD HEIGHT OF LOCATION OF GUTTERS (TYP) N 6' 10-1/2" SO THAT HEAD OF WINDOW TRIM ALIGNS w/ HEAD M O 0 OF DOOR TRIM(TYP) - -' PRIOR TO ORDERING WINDOWS FOR THIS LEVEL, VERIFY r r NN WINDOW OPENING SIZES IN FRAMING (TYP) - - - 5 FIRE SEPARATION BETWEEN RESIDENCE & ADU r-� 5 LJ BUILDER & CITY OF EDMONDS PLAN REVIEWER: SEE FIRE SEPARATION ASSEMBLY NOTES @ LOWER RIGHT OF THIS SHEET. 5'- 5" 3'- 5" 3'- 0" 3'- 4 1/2" 3'- 5" 3'- 4 1/2" SEE SHEET A-4.3 FOR DETAILS SHOWING ONE HOUR RATED WALL ASSEMBLY 11' - 1 10' - 2" DETAIL AND ONE HOUR RATED FLOOR / CEILING ASSEMBLY DETAIL. 39' - 0" 22' - 0" 61'-0" Level 2 Floor Plan FIRE SEPARATION BETWEEN RESIDENCE AND ACCESSORY DWELLING UNIT (SEE SHEET A-4.3 FOR ONE -HOUR FIRE RATED ASSEMBLY DETAILS) 1 DWELLING UNITS IN TWO-FAMILY DWELLINGS SHALL BE SEPARATED FROM EACH OTHER BY WALL 1 /4" 11-011 AND FLOOR ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR FIRE -RESISTANCE RATING WHERE = TESTED IN ACCORDANCE WITH ASTM E119, UL 263 OR SECTION 703.3 OF THE INTERNATIONAL North BUILDING CODE. FIRE RESISTANCE -RATED FLOOR/CEILING AND WALL ASSEMBLIES SHALL EXTEND TO AND BE TIGHT AGAINST THE EXTERIOR WALL, AND WALL ASSEMBLIES SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OFTHE ROOF SHEATHING. 1I KITCHEN CABINETS AND COUNTER LAYOUTS BY OWNER SELECTED KITCHEN DESIGNER. KITCHEN PLAN SHOWN IS SCHEMATIC ONLY. OWNER TO SELECT KITCHEN CABINETS STYLE, LAYOUT, APPLIANCES, PLUMBING FIXTURES, AND COUNTERTOP MATERIALS OPEN TO STAIRS / HALLWAY BELOW. WOOD STAIRS W/ PAINTED OR STAINED WOOD STAIR GUARDRAILS (36" HIGH) AND HANDRAILS. REFER TO STAIR NOTES ON SHEET A-4.1 FOR INFORMATION. STAIR MATERIAL SELECTION BY OWNER LINE OF WOOD HANDRAIL (36" HIGH) AT WALL AT SIDE OF STAIRS. SURFACE OF ROOF BELOW. SEE ROOF PLAN FOR TYPICAL ROOF CONSTRUCTION INFORMATION. LINE OF ROOF OVERHANG ABOVE. SEE ROOF PLAN FOR INFORMATION. L SHELVES AT LINEN AND STORAGE CLOSETS. COORDINATE TYPE OF SHELVES, NUMBER AND HEIGHTS OF SHELVES WITH OWNER TILE FLOORING AT ALL BATHROOMS AND LAUNDRY ROOM. SELECTION BY OWNER. 9.) PROVIDE 2 x 8 BLOCKING IN SHOWER FRAMING WALLS FOR FUTURE GRAB -BAR INSTALLATION 1� ALL INTERIOR PLUMBING WALLS SHALL BE INSULATED FOR SOUND CONTROL. WRAP PIPES IN FOAM INSULATION JACKETS (TYP) 1� PROVIDE BLOCKING IN ALL BATHROOMS FOR TOWEL BARS & TOILET PAPER HOLDERS. 1L QUARTZ COUNTERTOP W/ UNDERMOUNT SINK W/ MIRROR ABOVE AND WOOD CABINET BELOW AT ALL BATHROOMS (TYP). SINK, COUNTERTOP, CABINETS, MIRROR, AND PLUMBING FIXTURES 3 SELECTION BY OWNER. A-4.1 1L SOAKING TUB - SELECTION BY OWNER. BUILDING 14.1 SHOWER IN MASTER BATH: 36" x 60" LOW SECTION THRESHOLD ACCESSIBLE SHOWER PAN w/ TILE WALLS AND GLASS DOOR & SIDE PANEL. COORDINATE w/ OWNER 15. SHOWER IN BATHROOM #1: 32" x 54" LOW THRESHOLD ACCESSIBLE SHOWER PAN w/ TILE WALLS AND GLASS DOOR & SIDE PANEL. COORDINATE w/ OWNER M. SHOWER / TUB IN BATHROOM #2: ONE-PIECE TUB / SHOWER COMBO w/ DOUBLE FRAMELESS GLASS DOORS, AS SELECTED BY OWNER 17. COVERED PORCH W/ WATERPROOF WALKING SURFACE MEMBRANE (SELECTION & COLOR BY OWNER) OVER PRESSURE TREATED PLYWOOD AND PRESSURE TREATED WOOD FRAMING AND SUPPORT POSTS. REFER TO STRUCTURAL DRAWINGS FOR ALL DECK FRAMING INFORMATION. DECK WATERPROOFING TO BE INSTALLED BY QUALIFIED & AUTHORIZED WATERPROOF MEMBRANE INSTALLER AND ALL FLASHING AND WATERPROOFING DETAILS SHALL BE INSTALLED PER WATERPROOFING MEMBRANE MANUFACTURERS REQUIREMENTS AND SPECIFICATIONS. DECK TO SLOPE TOWARD EXTERIOR. INSTALL METAL FLASHING & WATERPROOF MEMBRANE PER MEMBRANE MANUFACTURERS DETAILS. INSTALL L-SHAPED METAL FLASHING AT THE JUNCTION BETWEEN WALL AND DECK, A GRAVEL STOP DRIP AT THE EDGE, AND GALVANIZED METAL PAN FLASHING UNDER THE DOOR. 1L PORCH (AT DOORWAY) IS 2" LOWER THAN FINISH FLOOR LEVEL. PORCH TO SLOPE (MIN. 1/4" PER FT) TO DRAIN TO EDGE. 19.) 36" HIGH (MIN.) GUARDRAIL AT PORCH. GUARDRAIL, BALUSTERS, & SUPPORT POSTS TO BE PRIMED & PAINTED CEDAR. SEE STAIR / GUARDRAIL NOTES FOR GUARDRAIL INFORMATION. SEE EXTERIOR BUILDING ELEVATION DRAWINGS. ZU LINE OF PORCH ROOF SUPPORT BEAMS - SEE STRUCTURAL DRAWINGS 2L PORCH ROOF SUPPORT COLUMNS W/ WOOD WRAP - SEE COLUMN DETAIL ON SHEET A-3.1 22.) UPPER PORCH CEILING PRIMED AND PAINTED TONGUE AND GROOVED BOARDS ON 1 x 4 STRAPPING (AT BOTTOM OF ROOF TRUSSES) TO ENSURE ALL CEILING BOARDS RUN IN A NORTH - SOUTH DIRECTION AT UPPER PORCH. 2� DRYER TO VENT DIRECTLY TO OUTSIDE WITH A MAXIMUM VENT LENGTH OF 25' AND A MAXIMUM OF TWO 90 DEGREE ELBOWS. CONTRACTOR SHALL INSTALL RECESSED METALDRYERBOX MODEL 4D / 22 GAUGE ALUMINIZED STEEL AT ROUGH -IN. VENT PIPE GOES UP AND EXITS AT ROOF OF HOUSE. DRYERBOX MODEL 4D DB-4D I NEW CONSTRUCTION 2X6 WALLS - VENTING DOWN M. ATTIC HATCH ACCESS PANEL: 3/4" x 22" x 42" (FITS INTO A 22 1/2" X 421/2" ROUGH OPENING) W/ 5 LAYERS OF RIGID R-10 INSULATION ADHERED TO PANEL @ ATTIC SIDE. TRIM OPENING W/ PTD. 1 x 4 TRIM BOARDS 2U CASED OPENING W/ TRIM TO ALIGN w/ HEAD TRIM @ DOORS RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Drawings for Conditional Use Permit for ADU 4-19-2023 Project Client & Project Applicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Leve12 Floor Plan 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 1 7-18-2023 PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 01 /23/23 A-203 Drawn By Author Level 2 Floor Plan Scale AS indicated Sheet Plot Date 7/17/2023 1:52:24 PM www.CarIColsonArchitect.com SCHEDULED ROOFING 2 x 4 ROOF LOOKOUTS @ 24" O.C. METAL DRIP EDGE 2 x 2 BETWEEN ROOF FLASHING LOOKOUTS SEE SHEET A-2.3 AND A-4.1 5l4 x 4 PRIMED & FOR NOTES ON ROOF PAINTED CONSTRUCTION & ROOF SMOOTH CEDAR SLOPES �' TRIM OVER 2 x 8 - ATTIC SPACE SMOOTH CEDAR RAKE BOARD PRIMED & PAINTED CEDAR 2 x PRIMED &PAINTED 10 FRIEZE BOARD EXTERIOR GRADE SEALANT / PLYWOOD ROOF SHEATHING CAULKING @ OVERHANG GABLE END ROOF TRUSS NOTE: ALL EXTERIOR TRIM SHALL BE PRE -PRIMED AT ALL SCHEDULED SIDING SIDES PRIOR TO INSTALLATION (TYPICAL AT ALL LOCATIONS) - Roof Rake Overhang at Gable Roof DrainEdge strip �° WeatherSeal trowel -applied membrane Step flashing taped and sealed Kick -out flashing Kick out and fascia taped and sealed 1 Shingles Wall sheathinp, Roof Kick -out Flashing 5 1 /411 = 1 1_011 ROOF ASSEMBLY PER NOTES TRUSS COMPANY TO PROVIDE SOLID @ BOTTOM OF THIS SHEET BLOCKING (W THREE 2" DIA. HOLES PER BLOCK) BETWEEN TRUSSES. CUT BLOCKING FROM 2 x MATERIAL. TOP EDGE OF BLOCKING TRIMMED TO MATCH ROOF SLOPE TRUSS COMPANY & FRAMER: HOLES IN 2 x 12 AND 2 x 6 BLOCKS TO ALIGN TO ALLOW FOR PROPER AIR FLOW 2 x BIRD BLOCK VENTS BETWEEN TRUSSES. RAISED HEEL @ UPPER ROOF TRUSSES. SEE ROOF PLAN FOR RAISED HEEL HEIGHTS. 5/4 x 3 PRIMED & PAINTED CEDAR TRIM BOARD METAL DRIP EDGE TO EXTEND DOWN - INTO GUTTER GUTTER GUARD. SEE ROOF PLAN SHEET 77 PRIMED AND FOR TYPE PAINTED EXTERIOR MITER JOINT @ PLYWOOD AT PER ROOF PLAN PTD. ALUM GUTTER INTERSECTION OF 2 x 6 AREA OF EXPOSED PAINTED. 2 x 6 HARDIE FASCIA & 2 x 8 ROOF RAKE EAVES (TYP) TRIM FASCIA BOARD SEE ROOF PLAN FOR III ROOF OVERHANG DIMENSIONS Upper Roof Overhang ROOF GENERAL NOTES THE CONTRACTOR SHALL REVIEW ALL ROOFING AND ROOFING FLASHING DETAILS WITH ROOFING VIANUFACTURER. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF ASSEMBLY AND ROOFING DETAILS IN ORDER TO ACHIEVE A WEATHERPROOF ROOFING ASSEMBLY. ROOFING MATERIALS 4SPHALT COMPOSITION SHINGLES - AS SELECTED BY OWNER ROOF FRAMING 'RE -ENGINEERED WOOD ROOF TRUSSES @ 24" O.C. WITH OVERFRAMING AT INDICATED AREAS. ROOF TRUSS MANUFACTURER WILL PROVIDE ROOF TRUSS FRAMING PLAN (TYPICAL) REFER TO STRUCTURAL FRAMING DRAWINGS AND ROOF TRUSS MANUFACTURER FRAMING DRAWINGS FOR ROOF FRAMING INFORMATION. ROOFTOP PENETRATIONS \10 PLUMBING VENT STACKS OR EXHAUST VENTS WILL BE ALLOWED ON FRONT PORTION OF BUILDING ROOF -ACING THE STREET. ALL ROOFTOP PENETRATIONS, PIPES, VENT STACKS SHALL BE FLASHED ACCORDING TO 4CCEPTABLE INDUSTRY STANDARDS. RESPONSIBILITY FOR ALL ROOFTOP FLASHING DETAILS SHALL BE WITH 3ENERALCONTRACTOR /ROOFING SUBCONTRACTOR. ROOF VALLEY FLASHING NSTALL CONTINUOUS EXPOSED METAL FLASHING (DARK BRONZE COLOR) OVER CONTINUOUS 36" WIDE (MIN.) 'GRACE ICE & WATER SHIELD MEMBRANE" AT ALL ROOF VALLEYS BELOW ROOFING MEMBRANEAND SHINGLES. ROOF ATTIC VENTING 'SEE ATTIC VENTING CALCULATIONS FOR MIN. NUMBER OF VENTS) 41_1_ EAVES SHALL HAVE BIRD BLOCK EAVE VENTS BETWEEN EXPOSED RAFTER TAILS. ALL ROOF RIDGES SHALL HAVE "SHINGLE -OVER" ROOF RIDGE VENTS. ATTIC VENTILATION: NET FREE VENTILATING AREA SHALL NOT BE _ESS THAN 1/150's OF THE AREA OF THE SPACE VENTILATED. 4 VAPOR BARRIER (P.V.A. PAINT) WILL BE INSTALLED ON THE WARM SIDE OF ATTIC INSULATION. A MINIMUM OF 1" MR SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND ROOF SHEATHING AT EAVE VENT LOCATIONS. DISTRIBUTE BIRD BLOCK VENTS EVENLY AT EXTERIOR WALLS OF ATTIC SPACE 3EE ATTIC VENTING CALCULATIONS. ROOF GUTTERS / DOWNSPOUTS NSTALL ALUMINUM GUTTERS AND DOWNSPOUTS AT LOCATIONS SHOWN ON ROOF PLAN AND BUILDING ELEVATIONS. PROVIDE BASKET STRAINER LEAFGUARDS IN GUTTERS AT TOP OF ALL DOWNSPOUTS. ALL DOWNSPOUTS SHALL DRAIN INTO BELOW GRADE DRAINAGE SYSTEM. CONTRACTOR TO COORDINATE THIS TEM PRIOR TO FOUNDATION WORK. CONTRACTOR SHALL COORDINATE PAINT COLOR FOR GUTTERS & DOWNSPOUTS WITH OWNER. PROVIDE AND INSTALL SCREENED GUTTER GUARDS AT ALL GUTTERS. ATTIC ACCESS HATCHES DROVIDE INSULATED ATTIC ACCESS HATCH AT LOCATIONS SHOWN ON UPPER LEVEL FLOOR PLAN. 4TTIC ACCESS HATCHES IN 1 HR. CEILING SHALL HAVE A 1 HR. FIRE RATING (IF 1 HR. CEILINGS ARE SPECIFIED -OR THIS PROJECT) 4TTIC ACCESS HATCHES SHALL BE 22" x 30" (MIN. SIZE) AND SHALL HAVE 30" MINIMUM UNOBSTRUCTED HEADROOM IN ATTIC ABOVE THE OPENING. 'OORDINATE OPENING WITH ROOF FRAMING. ATTIC & CRAWL SPACE HATCHES INSULATION REOMTS. 4CCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES (E.G., ATTICS AND CRAWL @PACES) SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 4CCESS SHALL BE PROVIDED TO ALL EQUIPMENT WHICH PREVENTS DAMAGING OR COMPRESSING THE NSULATION. A WOOD FRAMED OR EQUIVALENT BAFFLE OR RETAINER IS REQUIRED TO BE PROVIDED WHEN _OOSE FILL INSULATION IS INSTALLED, THE PURPOSE OF WHICH IS TO PREVENT THE LOOSE FILL NSULATION FROM SPILLING INTO THE LIVING SPACE WHEN THE ATTIC ACCESS IS OPENED AND TO DROVIDE A PERMANENT MEANS OF MAINTAINING THE INSTALLED R-VALUE OF THE LOOSE FILL INSULATION. SKYLIGHTS 'IF USED ON THIS PROJECT) INSTALL SKLIGHTS ON PRESSURE TREATED 2x4 WOOD CURBS AND NSTALL WITH METAL FLASHING PER SKYLIGHT MANUFACTURERS REQUIREMENTS. SKYLIGHT 3LAZING SHALL BE LAMINATED SAFETY GLASS. SKYLIGHT WELLS DROVIDE FLARED SKYLIGHT OPENING AT CEILING LEVEL WHERE SKYLIGHTS ARE INDICATED ON FLOOR AND HOOF PLANS. SKYLIGHT WELL WALLS SHALL BE PAINTED 1/2" GWB OVER 2 x 6 STUD FRAMING (@ 16" O.C.) WITH R-21 BATT NSULATION. BOTTOM LENGTH OF SKYLIGHT WELL SHALL BE 4'-0" MINIMUM OR AS DIRECTED BY BUILDER. ROOF EDGE DRIP FLASHING NSTALL PAINTED METAL DRIP EDGE FLASHING AT BOTTOM & SIDE EDGES OF ROOF. ROOF GUTTER GUARDS 4LL GUTTERS SHALL HAVE GUTTER GUARDS INSTALLED. GUTTER GUARD BY GUTTERGLOVE I FT. STAINLESS STEEL 5 IN. MICRO -MESH GUTTER GUARD (10-PACK) - COVERS 40, OF GUTTERS FALL PROTECTION 'ONTRACTOR SHALL INSTALL ROOF SAFETY ANCHORS PER CODE IF REQUIRED (FASTENED TO ROOF ASPHALT COMPOSTION ROOFING SHINGLES 5/4 x 4 CEDAR TRIM 2A0 CEDAR RAKE BOARD 5/4" X 10" CEDAR FRIEZE BOARD W/ SMOOTH FINISH (AT WALL BEYOND) NOTE: ALL EXTERIOR TRIM SHALL BE PRE -PRIMED AT ALL SIDES PRIOR TO INSTALLATION (TYPICAL AT ALL LOCATIONS) PAINTED SMOOTH HARDIE PLANK SIDING w/ 5" EXPOSURE 5/4 x 4 CORNER BOARD (TYP) /,/ - Roof Rake Elevation 2 1 „ = 1,_0" BUILDER NOTE: DOWNSPOUTS PLUMBER AND MECH. SUBCONTRACTOR NOTE: GUTTERS @ LOWER ROOF COORDINATE DOWNSPOUT LOCATIONS w/ OWNER AND PLUMBING FIXTURES SHALL SHARE AS MANY PLUMBING PIPE VENTS IN ORDER TO SEE LEVEL 2 PLAN FOR LOCATION OF FOUNDATION SUBCONTRACTOR PRIOR TO INSTALLATION OF MINIMIZE ROOF PENETRATIONS / GUTTERS ON LOWER ROOFS (TYP) BELOW GRADE PERIMETER DRAIN LINES AND INSTALLATION ROOFTOP PENETRATIONS ARE NOT ALLOWED AT CENTER ROOF FACING STREET. / GUTTERS @ UPPER ROOF OF DOWNSPOUTS @ UPPER AND LOWER ROOFS ALL PLUMBING VENT STACKS SHALL BE BLACK OR DARK GRAY - WHITE VENT SHADED AREA @ PERIMETER OF UPPER TRUSS RAISED HEEL / ROOF TRUSS MANUFACTURER NOTE: STACKS WILL NOT BE ALLOWED. ANY PLACEMENT OF WHITE VENTS SHALL BE ROOF INDICATES LOCATION OF GUTTERS ALL TRUSSES SHALL HAVE A 7" RAISED HEEL HEIGHT (TYP) REPLACED BY PLUMBING CONTRACTOR AT THEIR EXPENSE (TYP). SEE LEVEL 2 PLAN FOR LOCATION OF GUTTERS ON LOWER ROOF ROOF BELOW LJ LJ II \ � - 5/12 SLOPE 5/12 SLOPE - - 5/12 SLOPE 5/12 SLOPE------� 5/12 SLOPE 5/12 SLOPE TRUSS COMPANY & BUILDER NOTE: DOWNSPOUTS FRAMER COORDINATE DOWNSPOUT I SCISSOR TRUSSES LOCATIONS w/ OWNER PRIOR TO ARE LOCATED ABOVE w w INSTALLATION OF DOWNSPOUTSI MASTER BEDROOM & z w �I w @ UPPER AND LOWER ROOFS FAMILY ROOM ONLY LU - - IILU TRUSS RAISED HEEL o 10 -1/2" RAISED HEEL @ ALL UPPER LEVEL �J ROOF TRUSSES (TYP) JQ�� i SOLID BIRD BLOCK o F__ VENTS @ THIS WALL N IF LO II II w No COLo O w N G O 0- 9l� o T o 5' - 9 1 /8" co SOLID BIRD tLU BLOCK LU VENTS @ THIS WALL M 3 II A-4.1 I BUILDING III TRUSS COMPANY & FRAMER TO ADJUST 6 FRAMER CUT RAFTER TAILS @ o SCISSOR TRUSSES THIS ROOF TO MAKE T ARE LOCATED ABOVE SURE FASCIAS LINE UP N MASTER BEDROOM & T FAMILY ROOM ONLY FASCIA TO ALIGN (TYP) o I z- 5/12 SLOPE 5/12 SLOPE a� __J L- - - - - �, 5/12 SLOPE - F7 ROOF BELOW 5' - 11 1 /4" GUTTERS & DOWNSPOUTS PREFINISHED ALUMINUM GUTTERS AND DOWNSPOUTS TIED TO DRAINAGE SYSTEM GUTTER GUARDS INSTALL GUTTER GUARDS @ ALL GUTTERS AT ALL ROOFS. SEE NOTE @ RIGHT OF ROOF PLAN NO SOLID EAVE BLOCKS REQUIRED SINCE ROOF EDGE IS FURTHER THAN S AWAY FROM PROPERTY LINE ATTIC MINIMUM VENT CALCULATIONS THE FOLLOWING CALCULATIONS PROVIDE THE "MINIMUM" VENTING AS REQUIRED BY THE 2018 INTERNATIONAL RESIDENTIAL CODE. THIS CODE ALLOWS AREA OF VENTS REQUIRED TO BE 1/300TH OF ROOF AREA IF 50% OF VENTS ARE AT EAVE AND 50% OF VENTS ARE AT RIDGE AND IF A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF ATTIC INSULATION. THIS CODE ALLOWS AREA OF VENTS REQUIRED TO BE 1/150TH OF ROOF AREA IF 100% OF VENTS ARE AT EAVE AND IF A VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF ATTIC INSULATION. ATTIC VENTING CALCULATIONS (THE FOLLOWINC CALCULATIONS ARE FOR THE MINIMUM ALLOWABLE VENTS. SEE ROOF PLAN FOR LOCATION OF VENTS. CONTRACTOR SHALL INSTALL VENTING TO MEET THE FOLLOWING MINIMUM REQUIREMENTS. ALL EAVE VENTING SHALL BE DISTRIBUTED EVENLY TO ASSURE PROPER AIR FLOW THROUGH ALL PORTIONS OF THE ATTIC AREA. BIRD BLOCK VENTS SHALL BE EVENLY DISTRIBUTED AT FRONT AND REAR WALL OF BUILDING TO OBTAIN PROPER AIR FLOW IN ATTIC SPACE. INSTALL COR- A-VENT BELOW SHINGLE LINEAR VENTS WHERE ROOF OVERHANGS OR WALLS ARE LESS THAN 5TO PROPERTY LINE - USE SOLID EAVE BLOCKING IN THOSE AREAS). NOTE THAT ROOF PLANS MAY SHOW RIDGE VENTS IN EXCESS OF THE REQUIRED MINIMUM SHOWN IN THE CALCULATIONS BELOW. VENT TYPES 50% OF VENTS SHALL BE INSTALLED AT EAVES AND 50% OF VENTS SHALL BE INSTALLED AT ROOF RIDGE. ATTIC VENTING SHALL BE ACCOMPLISHED WITH BIRDBLOCK EAVE VENTS, SHINGLE -OVER RIDGE VENTS, AND BELOW -SHINGLE VENTS. • SHINGLE OVER RIDGE VENTS SHALL BE LOMANCO PRODUCT 10-OMNI RIDGE LOR94'. THIS PRODUCT IS SPECIFIED PER HIGH WINDS AT PROJECT SITE. (NO EXCEPTIONS ON THIS PRODUCT UNLESS APPROVED BY OWNER AND ARCHITECT) • BIRD BLOCK VENTS ARE BASED ON (3) 2-1/2" DIAMETER HOLES PER VENT BLOCK (NFVA = .094 SQ. FT. PER BLOCK) • RIDGE VENT AREA (0.076 SO. FT PER LIN FT) • SHINGLE -OVER VENT (0.0625 SO. FT. PER LIN. FT) ROOF ATTIC VENT CALC'S @ ROOF #1 (MAIN UPPER ROOF) 1) NEW ROOF AREA = 2669 S.F. (VENT AREA REQUIRED: 2669 DIVIDED BY 300 = 8.9 S.F.) 2) DISTRIBUTION OF VENTS: 50% @ RIDGE = 4.45 S.F., 50% @ EAVES = 4.45 S.F. 3) MINIMUM NUMBER OF VENTS RIDGE VENT (0.076 SQ. FT PER LIN. FT): 58.55 LIN. FT. OF RIDGE VENT (4.45 S.F. OF VENT AREA) BIRD BLOCK EAVE VENTS (0.094 SQ. FT. PER BLOCK): 48 BIRD BLOCKS (4.45 S.F. OF VENT AREA) 4) MINIMUM VENT AREA REQUIRED: 8.9 S.F. OF VENT AREA TRUSS RAISED HEEL Gq� CC 10 -1/2 RAISED HEEL @ ALL UPPER LEVEL ROOF `A A TRUSSES (TYP) �L VALLEY FLASHING SOLID BIRD W o �' METAL FLASHING OVER BLOCK NO PLUMBING VENT PIPES ON FLASHING MEMBRANE @ THIS WALL % ROOF FACING STREET (TYP) ALL ROOF VALLEYS (TYP) SikNGLE UNDERLAYMENT PROVIDE SHINGLE 5'- 5 1/8" RIDGE VENT UNDERLAYMENT @ ROOF w/ SKYLIGHTS (TYP) 0-' o �T� SLOPE OF 3.5 / 12(TYP) w N o LO U) J 1 "' w 0- SOLID BIRD vIN � � o BLOCK �Q- �, VENTS @ THIS WALL _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 �r---- - - - - - -- ----_----------- 1 SHADED AREA INDICATES FIRE SEPARATION WALLS (BETWEEN RESIDENCE & ADU) TO EXTEND TO FRAMER TO ADJUST / z UNDERSIDE OF ROOF BUILDING - - - - - - - - - - - - - - - - - - - CUT RAFTER TAILS @ �' SHEATHING. SEE SHEET SECTION THIS ROOF TO MAKE A-4.3 FOR DETAILS I SURE FASCIAS LINE UP N OROOETRUSS o MANFACTU ER: ROOF OVERHANGS o _ I THESE ROOFS ARE ALL ROOF OVERHANGS z 5/12 SLOPE 5/12 SLOPE I - DIFFERENT SLOPES. (EAVES AND RAKES) ARE 14", a� z I ADJUST OVERHANGS UNLESS NOTED OTHERWISE Lu THAT FASCIA WILL ALIGN FASCIA TO ALIGN (TYP) 1' - 2"- 0 1 o I 01 LINE OF EXTERIOR CIS C_] ROOF BELOW WALLS BELOW (TYP) ►� I I 5/12 SLOPE 5/12 SLOPE I J-1 J-1 III 1 LJ - - - - LJ III UPPER ROOF ATTIC AREA 2669 S.F. OF ATTIC AREA ,I I EAVE VENTS I GUTTERS @ UPPER ROOF RIDGE VENT BIRD BLOCK @ ALL EAVES, UNLESS NOTED SHADED AREA @ PERIMETER INSTALL SHINGLE -OVER OTHERWISE. SEE ROOF VENT OF UPPER ROOF INDICATES RIDGE VENT FOR ATTIC 1 CALCULATIONS FOR MINIMUM NUMBER OF LOCATION OF GUTTERS VENTILATION. SEE BIRD BLOCK VENTS (TYP) (TYP). SEE LEVEL 2 PLAN FOR CALCULATIONS FOR ATTIC LOCATION OF GUTTERS ON / ROOF VENTING ON THIS LOWER ROOF SHEET (TYP) I 1 N ROOF ATTIC VENT CALC'S @ ENTRY PORCH ROOF F- T (THIS ROOF WILL BE VENTED BY BIRD BLOCK VENTS ONLY, DIVIDE AREA BY 150) 1) ROOF AREA = 50 S.F. (VENT AREA REQUIRED: 50 DIVIDED BY 150 = 0.33 S.F.) 2) DISTRIBUTION OF VENTS: 100% @ EAVES = 0.33 S.F. 3) MINIMUM NUMBER OF VENTS BIRD BLOCK EAVE VENTS (0.094 SQ. FT. PER BLOCK): 4 VENT BLOCKS (0.33 S.F. OF VENT AREA) 4) MINIMUM VENT AREA REQUIRED: 0.33 S.F. OF VENT AREA ROOF ATTIC VENT CALC'S @ ROOF ABOVE GARAGE DOORS & FRONT PORTION OF HOME OFFICE THIS ROOF WILL BE VENTED BY BIRD BLOCK VENTS ONLY DIVIDE AREA BY 150 1) ROOF AREA = 46.8 S.F. (VENT AREA REQUIRED: 46.8 DIVIDED BY 150 = 0.31 S.F.) 2) DISTRIBUTION OF VENTS: 100% @ EAVES = 0.31 S.F. 3) MINIMUM NUMBER OF VENTS BIRD BLOCK EAVE VENTS (0.094 SO. FT. PER BLOCK): 4 VENT BLOCKS (0.31 S.F. OF VENT AREA) 4) MINIMUM VENT AREA REQUIRED: 0.33 S.F. OF VENT AREA ROOF ATTIC VENT CALC'S @ ACCESSORY DWELLING UNIT ENTRY PORCH (THIS ROOF WILL BE VENTED BY BIRD BLOCK VENTS ONLY, DIVIDE AREA BY 150) 1) ROOF AREA = 30 S.F. (VENT AREA REQUIRED: 30 DIVIDED BY 150 = 0.20 S.F.) 2) DISTRIBUTION OF VENTS: 100% @ EAVES = 0.20 S.F. 3) MINIMUM NUMBER OF VENTS BIRD BLOCK EAVE VENTS (0.094 SO. FT. PER BLOCK): 3 VENT BLOCKS (0.20 S.F. OF VENT AREA) 4) MINIMUM VENT AREA REQUIRED: 0.20 S.F. OF VENT AREA ROOF ATTIC VENT CALC'S @ LOW ROOFS ADJACENT TO REAR PORCH (THIS ROOF WILL BE VENTED BY BIRD BLOCK VENTS ONLY, DIVIDE AREA BY 150) 1) ROOF AREA = 72 S.F. (VENT AREA REQUIRED: 72 DIVIDED BY 150 = 0.48 S.F.) 2) DISTRIBUTION OF VENTS: 100% @ EAVES = 0.48 S.F. 3) MINIMUM NUMBER OF VENTS BIRD BLOCK EAVE VENTS (0.094 SO. FT. PER BLOCK): 6 VENT BLOCKS (0.48 S.F. OF VENT AREA) 4) MINIMUM VENT AREA REQUIRED: 0.48 S.F. OF VENT AREA Roof Plan North 1 ----------------- ROOF BELOW. SEE LEVEL 2 PLAN 1 5'- FOR LOCATIONS OF GUTTERS @ 7„ LOWER ROOFS (TYP) NO SOLID EAVE BLOCKS REQUIRED SINCE ROOF EDGE IS RESUB FURTHER THAN 5AWAY FROM Jul 19 2023 PROPERTY LINE CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Title Roof Plan 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 03/28/13 A-2,04 Drawn By Author Roof Plan Scale As indicated Sheet Plot Date 7/17/2023 1:52:47 PM www.CarIColsonArchitect.com II II II Q II LU II m Ln IIN o a CQ III m II L Q o Cn � U II Cn Cn I Ir I �' I II I W cc LU L� r I II M a 4 n U_ I II w II cr Q o `=' w m P to o cn _ CQ N °` Cc J ~ II Q o II "Cn Ln U Cn �L TRUSS COMPANY & FRAM SCISSOR TRUSSES ARE LOCATED ABOVE MASTER BEDROOM & FAMILY ROOM ONLY, PER SHADED GRAY AREA / TRUSS COMPANY & FRAMER \ OVERFRAME OVER THIS PORTION OF SCISSOR TRUSSES � III II i TRUSS COMPANY & FRAMER ALL NON -SHADED AREAS HAVE FLAT BOTTOM ROOF RAFTERS (TYP) u-)' ------ Cf �_ ----- -- TRUSS COMPANY & FRAMER — — _ — — — — — — — — SCISSOR TRUSSES ARE F LOCATED ABOVE MASTER I BEDROOM &FAMILY ROOM ONLY, PER SHADED GRAY AREA I I r_ � r, _ LJ I I IL_ LJ I _ L, LJ Roof Plan Showing Scissor Truss Locations J:��„ = 1,_ „ 3/1 6 0 North qF SECOND FLOOR SHEATHING HVAC SUPPLY DUCT EQ EQ I I + 1 T I 1 I I 2' - 011 SPACING OF 2nd FLOOR OPEN WEB TRUSSES SECOND FLOOR SHEATHING HVAC SUPPLY DUCT BUILDER NOTE: TRUSS COMPANY & FRAMER NOTE: AREA w/ DIAGONAL CROSS -HATCH REPRESENTS AREA IN AREA wl DIAGONAL CROSS -HATCH REPRESENTS AREA IN SECOND FLOOR OPEN WEB TRUSSES THAT HAVE AN SECOND FLOOR OPEN WEB TRUSSES THAT HAVE AN OPENING OF 20" WIDE TO ALLOW FOR HVAC SUPPLY OPENING OF 20" WIDE TO ALLOW FOR HVAC SUPPLY DUCTS TO BE LOCATED. DUCTWORK TO INDIVIDUAL DUCTS TO BE LOCATED AND NOT HAVE CONFLICT w/ VENTS SHALL BE COORDINATED w/ MECH. DIAGONAL BRACING IN OPEN WEB TRUSSES. OPENING SUBCONTRACTOR & OWNER 61' - 0" LOCATIONS SHOWN ARE AP OXIMATE 13'-0" 4'-8" 4'-8" 12'-0" 4'-8" 11'-01, r r-i L LJ ROOF BELOW CVI () TYP. T I � ROOF BELOW I I I I I ROOF BELOW LO I Master I I I edr om #2 I Bedroom #3 T Bedroom .___. rr r_ -- �11 lul Bathroom # Jim- ------------- Master ���� 1 � �®®. — ����� ���• � IAA 1 1 ■' Bathroom *�Cl Bal7hroom #�to Bedroom_ 1 �. Bathr•• ul Family Room E ►� 1 III FFE—MIKIND ROOF ROOF BELOW Covered BELOW Te Porch 1 11'- 9 1/2" Kitchen Home Office • • • • � � • � • • • Sul �II ADU Dinin Living Level 2 Floor Plan Showing HVAC Supply Line Openings in Open Web Trusses 2 3/16" = 1'-0" North Cfl RESUB T Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT OCnnAIn CI nnn 171"17I HING co T 11 _ O11 MINIMUM SHAFT WIDTH Level 2 Open Web Floor Truss w/ HVAC Duct Opening Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Pro-ject Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Title Roof Scissor Truss Plan & Second Floor Truss Plan 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 02/27/23 A-2,05 Drawn By Author Roof Scissor Truss Plan & Second Floor Scale Truss Plan As indicated Sheet Plot Date 7/17/2023 1:53:09 PM www.CarIColsonArchitect.com PLUMBING & MECH. EQUIPMENT, FIRE PROTECTION The requirements below are not the only requirements for plumbing and mechanical equipment to be installed in this residence. Contractor and subcontractors shall follow all applicable code and safety requirements when installing these fixtures or equipment items. IN ADDITION TO COMPLYING WITH ALL APPLICABLE PLUMBING REQUIREMENTS, THE PLUMBING CONTRACTOR SHALL CONFORM TO THE ADDITIONAL FOLLOWING PLUMBING REQUIREMENTS: * PRESSURE REDUCTION VALVE ON WATER SUPPLY LINE AS REQUIRED BY APPLICABLE CODES AND WATER UTILITY. * EXPANSION TANK REQUIRED ON HOT WATER TANK. * VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO EXTERIOR. • HOT WATER HEATER MUST BE SEISMICALLY ANCHORED OR STRAPPED AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE=THIRD OF ITS VERITCAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. 1" AIRGAP REQUIRED ON DISHWASHERS ALL PLUMBING FIXTURES SHALL COMPLY WITH FLOW RATES AS REQUIRED BY THE CITY OF EDMONDS CODE. THE REDUCED FLOW FIXTURE RATES ESTABLISHED BY THE WASHINGTON STATE ENERGY CODE SHALL NOT APPLY, UNLESS NOTED AS AN ENERGY CREDIT OPTION ON SHEET A-6.1 " NO PLUMBING VENT PIPES OR PROJECTIONS SHALL BE ALLOWED ON FRONT FACING ROOF OF BUILDING. SEE ROOF PLAN FOR NOTES. THE WATER SUPPLY FOR DISHWASHERS SHALL BE PROTECTED BY AN AIR GAP OR INTEGRAL BACKFLOW PREVENTER. PROVIDE VENT FOR DRYER TO OUTSIDE (MAX 15' WITH 2-90°S). EXTEND POP -OFF LINE FROM HOT WATER TANK OR BOILER TO THE FLOOR, TO AN INDIRECT WASTE RECEPTOR OR TO THE OUTDOORS. WHERE DISCHARGING TO THE OUTDOORS IN AREAS SUBJECT TO FREEZING, DISCHARGE PIPING SHALL BE FIRST PIPED TO AN INDIRECT WASTE RECEPTOR THROUGH AN AIR GAP LOCATED IN A CONDITIONED AREA. SEE P2803.6.1 FOR COMPLETE INSTALLATION DETAILS. CONDENSATE FROM ALL COOLING COILS OR EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREAS WHERE IT WOULD CAUSE A NUISANCE. A SECONDARY DRAIN OR AUXILIARY DRAIN PAN SHALL BE REQUIRED FOR EACH COOLING OR EVAPORATOR COIL WHERE DAMAGE TO ANY BUILDING COMPONENTS WILL OCCUR AS A RESULT OF OVERFLOW FROM THE EQUIPMENT DRAIN PAN OR STOPPAGE IN THE CONDENSATE DRAIN PIPING. CONDENSATE LINES FROM HIGH EFFICIENCY HEATERS MUST BE LOCATED WHERE THEY ARE NOT SUBJECT TO FREEZING. INSTALL HEATING AND AIR CONDITIONING EQUIPMENT ACCORDING TO MANUFACTURER'S SPECIFICATIONS. WHEN IN A CLOSET OR ALCOVE, THE SPACE SHALL BE A MINIMUM 12" WIDER THAN THE FURNACE WITH A MINIMUM 3" WORKING CLEARANCE REQUIRED AT REAR, SIDES AND TOP OF FURNACE. A LEVEL WORKING SPACE AT LEAST 30 INCHES DEEP AND 30 INCHES WIDE SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE SOURCE OF IGNITION IS NOT LESS THAN 18 INCHES ABOVE THE FLOOR IN GARAGES. APPLIANCES SHALL NOT BE LOCATED IN SLEEPING ROOMS, BATHROOMS, TOILET ROOMS, STORAGE CLOSETS OR SURGICAL ROOMS, OR IN A SPACE THAT OPENS ONLY INTO SUCH ROOMS OR SPACES. SEE G2406.2 FOR EXCEPTIONS. PROVIDE OUTSIDE COMBUSTION AIR TO ALL GAS APPLIANCES. EXCEPTION: DIRECT VENT APPLIANCES WITH SEALED COMBUSTION CHAMBERS. IF FURNACE & WATER HEATER ARE LOCATED IN GARAGE, PROVIDE 3" CONCRETE FILLED METAL POST WITH A 2' EMBEDMENT AND WITH A 30" EXTENSION ABOVE THE FLOOR TO PROTECT EQUIPMENT IN GARAGE FROM PHYSICAL DAMAGE UNLESS INSTALLED IN AN ALCOVE. ALL HOSE BIBS TO BE FROST -FREE WITH BACK FLOW DEVICE. TOILETS, MAXIMUM 1.6 GALLON PER FLUSH. SHOWERS AND FAUCETS, MAXIMUM 2.5 GALLONS PER MINUTE. AN EXPANSION TANK IS REQUIRED FOR ALL WATER HEATERS AND BOILERS. M2003. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST MOVEMENT DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE PLACED WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD DIMENSIONS OF THE TANK. THE LOWER STRAP SHALL BE A MINIMUM 4" ABOVE THE CONTROLS. PROVIDE PAN WHEN OVER WOOD FRAMED FLOOR. WHERE WATER HEATERS OR HOT WATER STORAGE TANKS ARE INSTALLED IN LOCATIONS WHERE LEAKAGE OF THE TANKS OR CONNECTIONS WILL CAUSE DAMAGE, THE TANK OR WATER HEATER SHALL BE INSTALLED IN A GALVANIZED STEEL PAN HAVING A MINIMUM THICKNESS OF 24 GAGE OR OTHER PANS FOR SUCH USE. THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR SHALL EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE NOT LESS THAN 6 INCHES AND NOT MORE THAN 24 INCHES ABOVE THE ADJACENT GROUND SURFACE. IRC P2801.5, P2801.5.2 SHOWER COMPARTMENTS SHALL HAVE AT LEAST 900 SQUARE INCHES OF INTERIOR CROSS -SECTIONAL AREA. SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 30 INCHES IN MINIMUM DIMENSION MEASURED FROM THE FINISHED INTERIOR DIMENSION OF THE SHOWER COMPARTMENT. FIRE PROTECTION SYSTEMS: ALARMS & SPRINKLERS CODE STANDARD INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION INTERNATIONAL FIRE CODE 1 COMPLIANCE METHOD: ENTIRE HOUSE TO RECEIVE SMOKE DETECTOR ALARMS LOCATED PER IRC SECTION R314. ALARMS ARE TO BE PERMANENTLY WIRED TO HOUSE'S POWER SOURCE AND HAVE BATTERY BACKUP, PER IRC SECTION R314.4. FIRE SPRINKLERS: THIS HOUSE IS REQUIRED TO BE SPRINKLERED PER CITY OF EDMONDS REQUIREMENTS. lip DaL L R D v4 _-----__ ll�_� qR 4 -----_ R 4 `_� R 4" Covered GAS FIREPLACE COORDINATE FIRE Entry Parch y IGNITION SWITCH FOR FIREPLACE PER MANUF. REQUIREMENTS. D R L- XL D SWATCH FOR PE INSTALL SWITCH PER OWNERS DIRECTION 4" 4" 4 4 LIGHTING ��J ��V ` tlr�, Home Office I _ IF _ Living�� SF 0 ' �� _----__ _---- DIMMER `� SD r 1 oc�� 1 SCMD SMOKE DETECTOR I Erxtry Vestibule SMOKE/CARBON O-',XR-,----_ R MONOXIDE DETECTOR 4' 4" 4 1 O R ------------------ �� TA �THERMOS_T' CHANDELIER DIMMER, 11 CH 4 ABOVE DINING TABLE Dlnin DIMMER �' /' ' _ !' 'I �` T R i ��� _ �� 1 -- 411 R _ ---- CH I I '' 411 --' R j j CHANDELIER -4-1 (� 2ND FLOOR 1 CEILING I I iv INSTALL 5 EVENLY CRAWL SPACE HATCH SMOKE ��� DETECTORy� 4" DISTRIBUTED R LIGHT FIXTURES IN O CRAWL SPACE 4" 4" R ,_-- ----_ R 0' 411 PENDANT 4 R SD -------------- SCMD w --- J m W 0 0 � 0 OUTLET FOR FAN / 11 4 i i EXHAUST FAN ABOVE \ RANGE ELECTRICAL LAYOUT ALL LIGHT FIXTURE TYPES & LOCATIONS, SWITCH LOCATIONS, AND WIRING CONNECTIONS ARE SCHEMATIC ONLY. ELECTRICIAN SHALL COORDINATE PURCHASE OF ITEMS, LOCATIONS AND LAYOUT WITH OWNER PRIOR TO INSTALLATION. PHONE. CABLE. AND DATA LINE LAYOUT CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL PHONE OUTLETS, CABLE TV OUTLETS, AND CABLE OUTLETS FOR COMPUTERS WITH OWNER - TYPICAL FOR LEVEL 1,2, & BASEMENT LANDSCAPE LIGHTING IF LANDSCAPE LIGHTING IS TO BE USED FOR THIS PROJECT, ELECTRICIAN SHALL COORDINATE LOCATIONS & TYPES OF ALL LANDSCAPE LIGHTING FIXTURES AND SWITCHES W/ OWNER ELECTRICAL. HEATING. & VENTILATION GENERAL NOTES VENTILATION & INDOOR AIR QUALITY Ll PENDANT LIGHT -- 4" WALL LIGHT ABOVE WINDOW TRIM 1, GFI r -�O I I I o - EXTERIOR OUTLETS ALL EXTERIOR OUTLETS SHALL BE WATERPROOFED SWITCHES IN WATERPROOF BOXES (TYP)- I ` INSTALLED E.V. CHARGER I I OUTLET @ CEILING FOR AUTOMATIC I GARAGE DOOR �� OPENER � � I i i I � I i � I � I i � I i I I i I � I i I , , H AT D TECT R / ALARM SHALL BEINTERCONNECT TO SMOKE DETECTOR j ALARMS IN WEL ING j H 2 Car Garage SMOKE/CARBON - - - - - - MONOXIDE DETECTOR I I � I I � I I � I I I I ' Pantry o I SD SMOKE ` R Pwdr. SF DETECTOR CM 4 1 � � I I 4„ 4,1 I. Kitchen I I I � I � I ` 0 411 SWITCH FOR 4 o S 5" -DIMMER LANDSCAPE LIGHTING- 5 OUTLETS BELOW` COUNTER FOR _ DISHWASHER & -- ----- GARBAGE DISPOSAL SOURCE SPECIFIC VENTILATION ELECTRICAL 1. SOURCE SPECIFIC VENTILATION: SOURCE SPECIFIC EXHAUST VENTILATION SHALL BE REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, AND OTHER ROOMS WHERE CONTRACTOR SHALL PERFORM ALL ELECTRICAL DESIGN AND INSTALLATION ON A DESIGN -BUILD BASIS AND SHALL APPLY FOR EXCESS WATER VAPOR OR COOKING ODOR IS PRODUCED. A SEPARATE PERMIT FOR ALL ELECTRICAL WORK. 1. BATHROOM EXHAUST.........................................80 CFM 1. CONTRACTOR SHALL COORDINATE ALL SELECTION OF ALL LIGHT FIXTURES, LIGHT FIXTURE LOCATIONS, AND ELECTRICAL 2. KITCHEN EXHAUST (IF APPLICABLE)...............100 CFM OUTLET LOCATIONS WITH OWNER PRIOR TO PURCHASE OR INSTALLATION OF FIXTURES. 3. LAUNDRY ROOM EXHAUST(IF APPLICABLE) ...... 50 CFM 2. CONTRACTOR SHALL COORDINATE ELECTRICAL OUTLET REQUIREMENTS FOR WASHER & DRYER UNITS WITH SELECTED WHOLE HOUSE EXHAUST FAN MANUFACTURERS REQUIREMENTS. 3. REFER TO INDOOR AIR QUALITY NOTES FOR BATHROOM EXHAUST FANS AND WHOLE HOUSE FANS FOR RESIDENTIAL UNIT. WHOLE HOUSE VENTILATION SYSTEMS: DWELLING UNIT SHALL BE EQUIPPED WITH A WHOLE 4. HEATING: THIS HOUSE SHALL BE HEATED WITH GAS HEAT PUMP WITH THERMOSTATS (PER WASHINGTON ENERGY CODE). HOUSE VENTILATION SYSTEM WHICH SHALL BE CAPABLE OF PROVIDING AT LEAST 0.35 AIR PROVIDE ELECTRICAL SERVICE AS REQUIRED BY MANUFACTURER. CHANGES PER HOUR, BUT NOT LESS THAN 15 CUBIC FEET PER MINUTE PER BEDROOM PLUS AN 5. PROVIDE AND INSTALL EXHAUST FAN OVER KITCHEN RANGE. ADDITIONAL 15 CUBIC FEET PER MINUTE. WHOLE HOUSE VENTILATION SYSTEMS SHALL BE 6. ALL OUTLETS IN BATHROOM, KITCHEN, AND WET AREAS SHALL BE GFI OUTLETS. DESIGNED TO LIMIT VENTILATION TO A LEVEL NO GREATER THAN 0.5 AIR CHANGES PER HOUR 7. LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES MUST HAVE LABEL STATING "SUITABLE FOR DAMP LOCATIONS". DURING NORMAL OPERATING CONDITIONS. 8. RECESSED CEILING FIXTURES MUST BE IC RATED. WHOLE HOUSE FAN SIZE...............................100 CFM 9. ISLAND AND PENINSULA COUNTER TOPS 12" OR WIDER SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET FOR EACH 4' OF WHOLE HOUSE FAN NOISE RATING .... 1.5 SONE (MAX.) COUNTER TOP. CONTROL REQUIRED: MANUAL AND AUTOMATIC CONTROL (24 HR. CLOCK TIMER) HIGH EFFICACY LIGHT BULB REQUIREMENTS OUTSIDE FRESH AIR INTAKE A MINIMUM OF 75 PERCENT OF THE LAMPS (BULBS) IN PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES OUTSIDE AIR: OUTSIDE AIR SHALL BE BROUGHT INTO RESIDENTIAL UNIT BY EXHAUST FANS / SHALL BE HIGH -EFFICACY LAMPS (THE OWNER HAS REQUESTED THAT 100% OF THE LAMPS BE HIGH EFFICACY. WHOLE HOUSE FANS WHICH WILL DRAW OUTSIDE AIR IN THROUGH FRESH AIR INTAKE VENTS SMOKE DETECTORS CONNECTED TO AND OPERATED BY SELECTED HVAC SYSTEM. WHERE OUTSIDE AIR SUPPLIES ARE CONTRACTOR SHALL PROVIDE AND INSTALL SMOKE DETECTORS AS REQUIRED BY APPLICABLE SAFETY CODES. SEPARATED FROM EXHAUST FANS POINT BY DOORS, THE DOORS SHALL BE UNDERCUT BY INCH. SMOKE DETECTORS SHALL BE HARD WIRED 110v WITH BATTERY BACKUP. VENTILATION DUCTS: ALL DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. 1. ROOM FRESH AIR INLETS SHALL COMPLY WITH THE FOLLOWING: HEAT DETECTORS IN GARAGES A) HAVE CONTROLLABLE AND SECURE OPENINGS. CONTRACTOR SHALL PROVIDE AND INSTALL HEAT DETECTOR /ALARM IN GARAGE AS REQUIRED BY APPLICABLE B) OPENINGS SHALL BE SCREENED OR PROTECTED TO PREVENT ENTRY OF INSECTS, LEAVES, OR SAFETY CODES (WAC 51-51-0314 /2018 IRC Section R314.2.3) . HEAT DETECTOR/ALARM SHALL BE OTHER MATERIALS. C) BE SLEEVED OR DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE INTERCONNECTED TO SMOKE DETECTOR ALARMS IN DWELLING. HEAT DETECTORS SHALL BE HARD WIRED (11Ov) WALL OR WINDOW IN WHICH THEY ARE PLACED. WITH BATTERY BACKUP. 1 C) PROVIDE A MINIMUM OF FOUR SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH 10 A B M N D T C CFM OF OUTDOOR AIR REQUIRED IN IRC TABLE M1507.3.3(1), IMC TABLE 403.8.1. FOR NEW CONSTRUCTION, AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH D) EACH OCCUPIABLE SPACE SHALL HAVE A MINIMUM OF ONE OPENING WITH FOUR SQUARE SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING UNITS WITHIN WHICH INCHES OF NET FREE OPENING AREA. FUEL -FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. EXHAUST OUTLET TERMINATION HEATING SYSTEM THIS RESIDENCE SHALL BE HEATED BY AN ELECTRIC HEAT PUMP HEATING AND COOLING SYSTEM. ALL DUCTWORK SHALL BE IN CONDITIONED SPACES. NO DUCTWORK ALLOWED IN CRAWL SPACE OR ATTIC AREAS. WATER HEATER THIS RESIDENCE SHALL HAVE AN ELECTRIC HEAT PUMP WATER HEATER INSTALLED IN GARAGE. 1.3 FEET MIN. FROM PROPERTY LINE 2.3 FEET FROM OPERABLE OPENINGS INTO A BUILDING. 3. 10 FEET FROM MECHANICAL AIR INTAKE. 4. ALL EXHAUST DUCTS IN UNCONDITIONED SPACE SHALL BE INSULATED WITH R-4. Al EXH. �J� FAN Storage -DIMMER v V I_I D R L SURFACE MTD._ L R D 4�� ' � _J ELEC. HEATER � 4�� I I I I Covered I I I 1 Porch I I I KRIL D I SURFACE M L------_J I I L R D 4 - ELEC. HEATER 4" ENERGY CODE OPTIONS HEATING OPTIONS I I i ELECTRIC HYBRID HEAT PUMP WATER HEATER Bedroom #4- - a sF ----- _ I I � I EXTERIOR OUTLETS ALL EXTERIOR OUTLETS SHALL BE WATERPROOFED SWITCHES IN WATERPROOF BOXES (TYP) SEE LEVEL 2 LIGHTING PLAN FOR LOCATIONS OF LIGHTS ON CEILING OPTION 2 HEAT PUMP 1.0 CREDIT ENERGY OPTIONS OPTION 1.3 EFFICIENT BUILDING ENVELOPE 0.5 CREDITS PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS: VERTICAL FENESTRATION U = 0.28 FLOOR R-38 SLAB ON GRADE R-10 PERIMETER AND UNDER ENTIRE SLAB BELOW GRADE SLAB R-10 PERIMETER AND UNDER ENTIRE SLAB OR COMPLIANCE BASED ON SECTION R402.1.4: REDUCE THE TOTAL CONDUCTIVE UA BY 5%. ;�7��[�7►F�i�_ll:i��_1:�_Tel:rd•],rr:%]�a�y[ala�rl���hrrl�_r�[•]����•�a:l��]r�� COMPLIANCE BASED ON R402.4.1.2: REDUCE THE TESTED AIR LEAKAGE TO 3.0 AIR CHANGES PER HOUR MAXIMUM AT 50 PASCALS. ALL WHOLE HOUSE VENTILATION REQUIREMENTS AS DETERMINED BY SECTION M1507.3 OF THE INTERNATIONAL RESIDENTIAL CODE OR SECTION 403.8 OF THE INTERNATIONAL MECHANICAL CODE SHALL BE MET WITH A HIGH EFFICIENCY FAN(S) (MAXIMUM 0.35 WATTS/CFM), NOT INTERLOCKED WITH THE FURNACE FAN (IF PRESENT). VENTILATION SYSTEMS USING A FURNACE INCLUDING AN ECM MOTOR ARE ALLOWED, PROVIDED THAT THEY ARE CONTROLLED TO OPERATE AT LOW SPEED IN VENTILATION ONLY MODE. OPTION 3.5 HIGH EFFICIENCY HVAC 1.5 CREDITS AIR -SOURCE, CENTRALLY DUCTED HEAT PUMP WITH MINIMUM HSPF OF 11.0. TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE HEATING EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY. OPTION 4.1 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM OPTIONS 0.5 CREDITS ALL SUPPLY AND RETURN DUCTS LOCATED IN AN UNCONDITIONED ATTIC SHALL BE DEEPLY BURIED IN CEILING INSULATION IN ACCORDANCE WITH SECTION R403.3.7. FOR MECHANICAL EQUIPMENT LOCATED OUTSIDE THE CONDITIONED SPACE, A MAXIMUM OF 10 LINEAR FEET OF RETURN DUCT AND 5 LINEAR FEET OF SUPPLY DUCT CONNECTIONS TO THE EQUIPMENT MAY BE OUTSIDE THE DEEPLY BURIED INSULATION. ALL METALLIC DUCTS LOCATED OUTSIDE THE CONDITIONED SPACE MUST HAVE BOTH TRANSVERSE AND LONGITUDINAL JOINTS SEALED WITH MASTIC. IF FLEX DUCTS ARE USED, THEY CANNOT CONTAIN SPLICES. DUCT LEAKAGE SHALL BE LIMITED TO 3 CFM PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA. AIR HANDLER(S) SHALL BE LOCATED WITHIN THE CONDITIONED SPACE. 5.5 OPTION 5.'k EFFICIENT WATER HEATING 2.0 CREDITS WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING: ELECTRIC HEAT PUMP WATER HEATER MEETING THE STANDARDS FOR TIER III OF NEEA'S ADVANCED WATER HEATING SPECIFICATION TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY. PREMIER® HYBRID ELECTRIC HEAT PUMP 66-GALLON WATER HEATER (MODEL# HPX-66-DHPT) ENERGY FACTOR = 3.6 TOTAL ENERGY CODE OPTION CREDITS 6.0 CREDITS GFI FM i I DDML ,--411 - L.E.D. STRIP LIGH (TYP. IN GARAGE) / I 1800 LUMENS / 30 I KELVIN I SUB -PANEL Oi FUTURE E.V. L L L -1 CHARGER OI I I I - - - - - - OUTLET @ ®\I CEILING FOR -----_ AUTOMATIC HD `p / / GARAGE DOOR OPENER ' HEAT DETECTOR/ALARM SHALL BE INTERCONNECTED 1 TO SMOKE DETECTOR ALARM i IN DWELLING � I I ----__ ---------------- ELECTRICAL FIXTURE LEGEND SMOKE & CARBON LJ MONOXIDE DETECTOR SCMD SMOKE DETECTOR SD RECESSED LIGHT FIXTURE R 4" DIAMETER RECESSED LIGHT FIXTURE D R L DAMP LOCATION 5" DIAMETER 4° RECESSED LIGHT FIXTURE D3: R L DAMP LOCATION 4" DIAMETER 4" RECESSED LIGHT FIXTURE R 5" DIAMETER 5" RECESSED ADJUSTABLE LIGHT FIXTURE R 4" DIAMETER - DIRECTIONAL FOR ART DISPLAY PENDANT LIGHT FIXTURE @ ENTRY PORCH & KITCHEN ISLAND. T MIN. 34" ABOVE ISLAND �� S 1 SEMI -FLUSH LIGHT FIXTURE SF CEILING MOUNTED LIGHT 412 � FIXTURE / 12" DIA. " DIA. CEILING MOUNTED LIGHT jFIXTURE. SIZE SELECTED BY OWNER WALL MOUNTED EXTERIOR LIGHT FIXTURE WALL MOUNTED INTERIOR LIGHT ,-,O FIXTURE �YC WALL MOUNTED INTERIOR SCONCE 700 LUMENS EXHAUST FAN Timer Q Switch EXHAUST FAN w/ EXH. FAN TIMER @ SWITCH ELECTRICAL OUTLET 240 V OUTLET 024�O WEATHER PROOF ELECTRICAL OUTLET OWP LIGHT SWITCH LED UNDER CABINET LIGHTING L.E.D. LINEAR SURFACE MOUNTED LIGHT O O� CEILING FAN W/ LIGHT FIXTURE 00 1) PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. SMOKE DETECTORS SHALL BE DIRECT WIRED, 110 VOLT INTERCONNECTED WITH A BATTERY BACKUP. 2) PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFI) AS REQUIRED BY THE NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. 3) UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR: SWITCHES 42" OUTLETS 16" TELEPHONE 16" TELEVISION 16" Level 1 Lighting / Outlet / Detector Plan 1 /4" = 1 ' - 0" North BUILDER SPRINLER NOTE: THIS HOUSE IS TO BE SPRINKLERED PER CITY OF EDMONDS REQUIREMENTS. SPRINKLER SUBCONTRACTOR SHALL PROVIDE LAYOUT TO BE COORDINATED w/ CITY OF EDMONDS REQUIREMENTS, BUILDER, AND OWNERS BUILDER NOTE: ALL LIGHITNG AND OUTLET LOCATIONS ARE SCHEMATIC AND SHALL BE APPROVED / COORDINATED w/ OWNER BEFORE ANY ELECTRICAL WORK HAS BEGUN (TYPICAL @a ALL LEVELS) RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture TangResidence Project Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Level 1 Lighting / Detectors / Ventilation Notes 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 1 7-18-2023 PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 04/22/13 A-2,s6 Drawn By Author Level 1 Lighting / Detectors / Ventilation Scale Notes As indicated Sheet Plot Date 7/17/2023 1:53:43 PM www.CarIColsonArchitect.com D�L L R D L-----------------0 L_ —1 North Level 2 Lighting, Outlet, & Detector Plan 1 1 /411 = 1 1-011 BUILDER SPRINKLER NOTE: THIS HOUSE IS TO BE SPRINKLERED PER CITY OF EDMONDS REQUIREMENTS. SPRINKLER SUBCONTRACTOR SHALL PROVIDE LAYOUT TO BE COORDINATED w/ CITY OF EDMONDS REQUIREMENTS, BUILDER, AND OWNERS BUILDER NOTE: ALL LIGHTING AND OUTLET LOCATIONS ARE SCHEMATIC AND SHALL BE APPROVED / COORDINATED w/ OWNER BEFORE ANY ELECTRICAL WORK HAS BEGUN (TYPICAL Qa ALL LEVELS) ELECTRICAL FIXTURE LEGEND SMOKE & CARBON MONOXIDE DETECTOR SCMD —SMOKE DETECTOR SD r—RECESSED LIGHT FIXTURE 3 4" DIAMETER r RECESSED LIGHT FIXTURE D/R L DAMP LOCATION 5" DIAMETER 411 rL RECESSED LIGHT FIXTURE D RDAMP LOCATION 4" DIAMETER 4" r RECESSED LIGHT FIXTURE 5" DIAMETER R 0-5" RECESSED ADJUSTABLE LIGHT FIXTURE R 4" DIAMETER - DIRECTIONAL FOR ART DISPLAY PENDANT LIGHT FIXTURE @ ENTRY PORCH & KITCHEN ISLAND. �TrJ MIN. 34" ABOVE ISLAND S-1 / SEMI -FLUSH LIGHT FIXTURE SF CEILING MOUNTED LIGHT CM �� FIXTURE / 12" DIA. 12„ DIA. CEILING MOUNTED LIGHT FIXTURE. SIZE SELECTED BY OWNER WALL MOUNTED EXTERIOR LIGHT FIXTURE WALL MOUNTED INTERIOR LIGHT FIXTURE WALL MOUNTED INTERIOR SCONCE 700 LUMENS IEXHAUST FAN Timer @ Switch EXHAUST FAN w/ EXH. FAN TIMER @ SWITCH ELECTRICAL OUTLET 0240 240 V OUTLET ol*�ELECTRICAL WEATHER PROOF OUTLET WP LIGHT SWITCH LED UNDER CABINET LIGHTING L.E.D. LINEAR SURFACE MOUNTED LIGHT OO,� CEILING FAN W/ LIGHT FIXTURE 00 1) PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. SMOKE DETECTORS SHALL BE DIRECT WIRED, 110 VOLT INTERCONNECTED WITH A BATTERY BACKUP. 2) PROVIDE AND INSTALL GROUND FAULT CIRCUIT INTERRUPTERS (GFI) AS REQUIRED BY THE NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES. 3) UNLESS OTHERWISE INDICATED, INSTALL SWITCHES AND RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR: SWITCHES 42" OUTLETS 16" TELEPHONE 16" TELEVISION 16" RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson -Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Project Client & Project Applicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Title Level 2 Lighting / Detectors Plan 77543 REGISTERS 7 1ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 1 7-18-2023 PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 09/12/18 A-2,07 Drawn By Author Level 2 Lighting / Detectors Plan Scale 1 /4" = V-0" Sheet Plot Date 7/17/2023 1:54:10 PM www.CarIColsonArchitect.com LINE OF FINISH GRADE LINE OF FINISH GRADE. SEE CIVIL GRADING DRAWINGS FOR ALL SITE GRADING INFORMATION. HOLD FINISH GRADE 6" BELOW BOTTOM OF SIDING (TYP). PRE -PRIMED EXTERIOR WOOD ALL EXTERIOR WOOD TRIM & CORNER BOARDS SHALL BE PRE -PRIMED (BY MANUFACTURER OR BUILDER) AT ALL SIDES BEFORE INSTALLATION AND PAINTING OF FINISH COAT - TYPICAL AT ALL LOCATIONS - ALL END CUTS SHALL BE PRIMED BEFORE INSTALLATION LINE OF MAXIMUM BUILDING HEIGHT (ELEVATION 200.74') LINE OF PROPOSED BUILDING HEIGHT (ELEVATION 200.21) 11 4 9 8 = c� LLI 7 A A 0 O 0 __ C7 6 -- - ------- - Z _ N J T W = co 5 _ N - m 4 ROOF SLOPE SEE ROOF PLAN FOR ALL ROOF SLOPESINFO BUILDER / PLUMBER / HVAC CONTRACTOR WINDOW TRIM DRIP FLASHING FRIEZE BOARDS REFER TO ROOF VENTING PLAN FOR ALL WINDOWS SHALL METAL DRIP FLASHING @ HEAD 2 x 8 CEDAR FRIEZE BOARD BEHIND ALL ALLOWED AREAS FOR ALL ROOFTOP VENTING OF WINDOW (TYP). UPPER LEG OF FLASHING SHALL BE EAVES (TYPICAL). SEE EAVE DETAIL OF PLUMBING VENTS, EXHAUST VENTS (TYP) TUCKED UP UNDER WEATHER RESISTIVE BARRIER (TYP) M ME 12" WIDE LANDSCAPE BLOCK RETAINING WALL LINE OF AVERAGE FINISH GRADE FOOTINGS DASHED LINE INDICATES LINE OF AVERAGE TOP & BOTTOM OF FOOTING ELEVATIONS ARE WINDOWS FINISH GRADE FOR BUILING HEIGHT APPROXIMATE ONLY. BOTTOM OF FOOTINGS SHALL ALL WINDOWS SHALL BE DOUBLE CALCULATION BE AT LEAST 18" BELOW FINISH GRADE. ACTUAL GLAZED WINDOWS PAINTED ELEVATIONS WILL DEPEND UPON DEPTH OF CEDAR TRIM EXTERIOR. BEARING SOIL. (TYPICAL @ALL FOOTINGS) REFER TO SHEET A-5.1 AND A-5.2 FOR WINDOW SCHEDULE AND DETAILS 0 w 0 J J Q F- - - 0 � w _ W M 2 co (3 N 0 Z Z V Ei N J ZD m m x Q 3 SAFETY GLASS IN ENTRY DOOR & AT ADJACENT WINDOWS �4�IIII 1� 11111 BUILDER NOTE: THERE ARE NO STEPS FROM ENTRY TO HOUSE. THIS WAS DONE TO KEEP ROOF WITHIN 26 HEIGHT LIMITS AND FOR ACCESSIBILITY PURPOSES NORTH ELEVATION ME11I' 110 MINIM1110 I I ■i■ MIN �M I I I min ■■ [LE - WRAPPED PORCH COLUMNS. SEE STRUCT. DRAWINGS & SHEET A-4.2 FOR COLUMN WRAP DETAILS LINE OF 26 MAXIMUM BUILDING HEIGHT SKYLIGHTS SKYLIGHT --------------------------------------------------------------------------- 7 LINE -- -`- LINE OF HIGHEST POINT OF ROOF SKYLIGHT I w co w 77 +-4 �H WALL. ROOF. & FLOOR CONSTRUCTION REFER TO CONSTRUCTION ASSEMBLY NOTES ON SHEET A-4.1 FOR NOTES ON ALL WALL, ROOF, & FLOOR CONSTRUCTION (TYP) BRACKET CAP FLASHING PTD. GALV. METAL FLASHING W/ DRIP EDGE AT TOP OF ALL BRACKETS AT SHED ROOF. DRIP EDGES @ SIDES & FRONT OF BRACKET. EXTEND METAL CAP FLASHING BACK TO WALL BEYOND. ALL RAKE BOARDS SHALL HAVE A TWO -CUT PLUMB VERTICAL AND HORIZONTAL SURFACE, PER DETAIL ON SHEET A-2.4 12 To Plate 18.76 DOWNSPOUTS SEE ROOF PLAN ON SHEET A-2.4 FOR ALL DOWNSPOUT LOCATIONS BUTT JOINTS @ HARDIE SIDING INSTALL SIMPLICITY TOOLS METAL JUNCTION FLASHING BEHIND ALL BUTT JOINTS. MINIMIZE BUTT JOINTS AS NUCH AS POSSIBLE (TYP) Level 2 10.67 11 To Plate 9.09 SINGLE HUNG WINDOWS SINGLE HUNG WINDOWS (TYP) PAINTED HARDIE SIDING w/ SMOOTH FINISH & 5" EXPOSURE =(ELEV.175.74�) 10 LINE OF LEVEL 1 FLOOR (ELEV.175.56) Level 1 0.00 T.O. F. W . -0.20 LINE OF TOP OF FOUNDATION WALL (ELEV.175.36') FINISH FLOOR ELEVATIONS BUILDER TO CONFIRM ALL FINISH FLOOR ELEVATIONS WITH SITE GRADING PLAN PRIOR TO ANY CONSTRUCTION LINE OF EXISTING GRADE ALL RAKE BOARDS SHALL HAVE A TWO -CUT PLUMB VERTICAL AND HORIZONTAL SURFACE, Z Z PER DETAIL ON SHEET A-2.4 Level 2 Top Plate 18.76 0 0 co E❑D0 == C i i I AM I SAFETY GLASS IN ENTRY 36" PRIMED & PAINTED CEDAR GUARDRAIL W/ GUARDRAIL POST ATTACHMENT. SEE DETAIL ON SHEET A-4.3 DOOR & AT ADJACENT 4 x 4 POSTS & 2x2 BALUSTERS. CAP TO BE FOR ATTACHING GUARDRAIL POST TO STRUCTURAL FRAMING WINDOW HAVE SLOPED SURFACES & TO BE CUT FROM 2 x 6 CEDAR. ALL SPACING TO PREVENT PTD. CEDAR 1 x WOOD WRAPPED @ SUPPORT BEAM. SEE PASSAGE OF 4" DIA. SPHERE (TYP) STRUCT. DRAWINGS & SHEET A-4.3 FOR ADD'L. INFO. METAL DRIP EDGE FLASHING (BELOW PORCH 2 X 10 PAINTED CEDAR WITH UPPER WOOD TRIM AND METAL WATERPROOF FLOOR SURFACE) OVER 1 x 3 PTD. CEDAR DRIP FLASHING AT TOP OF TRIM. 2 x 8 WOOD TRIM TO WRAP TRIM. COORDINATE THIS FLASHING W/ OWNER (TYP) AROUND ALL 3 SIDES OF UPPER PORCH AS SHOWN PORCH FLOOR FRAMING TO SLOPE AWAY FROM SOUTH ELEVATION EXTERIOR WALLS BEYOND. SEE STRUCT. DRAWINGS D 1 /4" = 1 '-0" �� SEE NORTH ELEVATION DRAWING FOR TYPICAL EXTERIOR NOTES PREPRIMING AND PAINTING OF EXTERIOR WOOD SURFACES ANY NATURAL WOOD SIDING OR WOOD TRIM @a EXTERIOR SHALL BE PRE - PRIMED (BY PAINTER OR SUPPLIER) AT ALL SIDES (BEFORE INSTALLATION) AND SHALL BE PAINTED W/ EXTERIOR PAINT AS SELECTED BY OWNER. ALL EXTERIOR WOOD TRIM SHALL HAVE SMOOTH SURFACE NOTES TO BUILDING ELEVATIONS NOTE: THE TERM "BUILDER" REFERS TO THE DEVELOPER WHOSE RESPONSIBILITY INCLUDES THAT OF GENERAL CONTRACTOR. THESE NOTES ARE FOR THE EXTERIOR BUILDING ELEVATION DRAWINGS AT ALL UNITS.. ALL NOTES MAY NOT APPLY TO EACH UNIT. THESE ELEVATION NOTES ARE FOR ALL SINGLE-FAMILY HOUSES DESIGNED BY ARCHITECT. SOME NOTES MAY REFER TO CONSTRUCTION TYPES OR ITEMS NOT FOUND IN THIS PROJECT. 11 PAINTED METAL INSULATED OVERHEAD CARRIAGE STYLE GARAGE DOOR 16' x 8' (AUTOMATIC OPENER) W/ VISION PANELS AS SHOWN. AMARR GARAGE DOORS - CLASSICA - TUSCANY DOOR STYLE - MADEIRA WINDOWS. R1 PAINTED HARDIE TRIM AT HEAD OF GARAGE DOOR. 5/410 HEAD PIECE WITH CEDAR TRIM AT TOP AND BOTTOM AS SHOWN (SELECTION BY BUILDER). SEE WINDOW SCHEDULE ABOUT METAL HEAD FLASHING REQUIREMENTS. 3). WRAPPED PORCH OR DECK SUPPORT COLUMN. REFER TO ENTRY PORCH COLUMN DETAIL FOR INFORMATION. ALL POSTS SHALL BE FLASHED TO PREVENT WATER INTRUSION INTO COLUMN ENCLOSURE. 4.) ASPHALT ROOF SHINGLES. SEE SHEET A-4.1 FOR INFORMATION. L PAINTED HARDIEBOARD SIDING W/ SMOOTH FINISH. SEE BUILDING SECTIONS FOR NOTES ON WALL ASSEMBLY. L INSULATED MILGARD ULTRA WINDOWS - REFER TO FLOOR PLAN & WINDOW SCHEDULE FOR TYPES. 7.) PRE -PRIMED & PAINTED SMOOTH CEDAR TRIM AROUND WINDOWS & DOORS. SEE DETAILS ON SHEET A-5.1 FOR TRIM INFORMATION. 8.) PRE -PRIMED & PAINTED SMOOTH CEDAR 4 x 6 CRAFTSMAN STYLE ROOF BRACKETS w/ PAINTED METAL FLASHING @ TOP OF HORIZONTAL BRACKET BOARD L PRIMED & PAINTED CEDAR 1 x 4 TRIM @ SIDING CORNERS. 1P.1 1X PTD. PRIMED & PAINTED CEDAR BOARD WRAP (W/ SMOOTH FINISH) AT ROOF OR FLOOR SUPPORT BEAM AT PORCH. IL PRIMED & PAINTED HARDIE SHAKE STRAIGHT BOARD SIDING PANELS AT SELECTED GABLE END WALLS 12. 2x PAINTED CEDAR TRIM BOARDS (AT WALL SURFACE BEHIND ROOF OVERHANG) W/ PRIMED & PAINTED CEDAR 1X4 TRIM 131 ELECTRIC METER - INSTALL PER ELECT. CO. REQUIREMENTS. 14. GAS METER - INSTALL PER GAS CO. REQUIREMENTS. 15. PAINTED FIBERGLASS INSULATED DOOR. STYLE SELECTION BY OWNER. 16. PORCH ROOF FRAMING: PREMANUFACTURED ROOF TRUSSES @ 24" O.C. W/ PAINTED 11/32" PLYWOOD CEILING (PLYBEAD CLASSIC PANELS) 17. COVERED DECK W/ WATERPROOF WALKING SURFACE MEMBRANE - SEE LEVEL 2 FLOOR PLAN FOR NOTES 18. PRIMED AND PAINTED CEDAR, GUARDRAIL, CAP, AND POSTS. GUARDRAIL SHALL BE 36" HIGH ABOVE DECK 14" TJI FLOOR JOISTS PLUS 3/4" FLOOR SHEATHING (TYP) Level 2 10.67 Level 1 To Plate 9.09 - PAINTED METAL INSULATED OVERHEAD CARRIAGE STYLE GARAGE DOOR 9' x 7' (AUTOMATIC OPENER) W/ VISION PANELS AS SHOWN. AMARR GARAGE DOORS - CLASSICA - TUSCANY DOOR Q2 STYLE - MADEIRA WINDOWS. a, LINE OF AVERAGE FINISH GRADE (ELEV.175.74') LINE OF LEVEL 1 FLOOR (ELEV.175.56') Level 1 0.00 T.O.F.W. -0.26 LINE OF TOP OF FOUNDATION WALL (ELEV.175.36') RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Drawings for Conditional Use Permit for ADU 4-19-2023 Project Client & Project Applicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 North and South Elevations 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 11 I7-18-2023 I PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 08/15/21 A-3,sl Drawn By Author North and South Elevations Scale 1 /4" = V-0" Sheet Plot Date 7/17/2023 1:54:36 PM www.CarIColsonArchitect.com LINE OF MAXIMUM BUILDING HEIGHT LINE OF PROPOSED BUILDING HEIGHT LINE OF AVERAGE FINISH GRADE DASHED LINE INDICATES LINE OF AVERAGE FINISH GRADE FOR BUILING HEIGHT CALCULATION - LINE OF FINISH GRADE LINE OF FINISH GRADE. SEE CIVIL GRADING DRAWINGS FOR ALL SITE GRADING INFORMATION. HOLD FINISH GRADE 6" BELOW BOTTOM OF SIDING (TYP). FOOTINGS 11 M � TOP & BOTTOM OF FOOTING ELEVATIONS ARE APPROXIMATE ONLY. BOTTOM OF FOOTINGS SHALL BE AT LEAST 18" BELOW FINISH GRADE. ACTUAL ELEVATIONS WILL DEPEND UPON DEPTH OF BEARING SOIL. (TYPICAL @ ALL FOOTINGS) LINE OF MAXIMUM BUILDING HEIGHT LINE OF PROPOSED BUILDING HEIGHT LINE OF AVERAGE FINISH GRADE DASHED LINE INDICATES LINE OF AVERAGE FINISH GRADE FOR BUILING HEIGHT CALCULATION - LINE OF FINISH GRADE LINE OF FINISH GRADE. SEE CIVIL GRADING DRAWINGS FOR ALL SITE GRADING INFORMATION. HOLD FINISH GRADE 6" BELOW BOTTOM OF SIDING (TYP). FOOTINGS TOP & BOTTOM OF FOOTING ELEVATIONS ARE APPROXIMATE ONLY. BOTTOM OF FOOTINGS SHALL BE AT LEAST 18" BELOW FINISH GRADE. ACTUAL I I ELEVATIONS WILL DEPEND UPON DEPTH OF BEARING SOIL. (TYPICAL @ ALL FOOTINGS) LI 11 Ll LI 11 ll EAST ELEVATION 1 /4" = 1 -0" 6A1 LnlVn VVVn. METAL OR FIBERGLASS DOOR @ SIDE WALL OF GARAGE SKYLIGHT @ ROOF BEYOND . LIL— �L—-—LIL—LILJLI—LIB III III III III WEST ELEVATION 2 1 /4" = 1 '-011 SEE NORTH ELEVATION DRAWING FOR TYPICAL EXTERIOR NOTES PREPRIMING AND PAINTING OF EXTERIOR WOOD SURFACES ANY NATURAL WOOD SIDING OR WOOD TRIM @a EXTERIOR SHALL BE PRE - PRIMED (BY PAINTER OR SUPPLIER) AT ALL SIDES (BEFORE INSTALLATION) AND SHALL BE PAINTED W/ EXTERIOR PAINT AS SELECTED BY OWNER. ALL EXTERIOR WOOD TRIM SHALL HAVE SMOOTH SURFACE ROOF SLOPE SEE ROOF PLAN FOR ALL ROOF SLOPES INFO Level 2 Tog Plate 18.76 DOWNSPOUTS SEE ROOF PLAN ON SHEET A-2.4 FOR ALL DOWNSPOUT LOCATIONS WALL, ROOF, & FLOOR CONSTRUCTION REFER TO CONSTRUCTION ASSEMBLY NOTES ON SHEET A-4.1 FOR NOTES ON ALL WALL, ROOF, & FLOOR CONSTRUCTION (TYP) Level 2 10.67 BUILDER NOTE: THERE ARE NO STEPS FROM ENTRY TO HOUSE. THIS WAS DONE TO KEEP ROOF WITHIN 25' HEIGHT LIMITS AND FOR ACCESSIBILITY PURPOSES LINE OF AVERAGE FINISH GRADE (ELEV.175.74') LINE OF LEVEL 1 FLOOR (ELEV.175.56) _ Level 0.00 LINE OF TOP OF FOUNDATION WALL (ELEV.175.36') FINISH FLOOR ELEVATIONS BUILDER TO CONFIRM ALL FINISH FLOOR ELEVATIONS WITH SITE GRADING PLAN PRIOR TO ANY CONSTRUCTION ROOF SLOPE SEE ROOF PLAN FOR ALL ROOF SLOPES INFO Level 2 To Plate 18.76 DOWNSPOUTS SEE ROOF PLAN ON SHEET A-2.4 FOR ALL DOWNSPOUT LOCATIONS WALL, ROOF, & FLOOR CONSTRUCTION REFER TO CONSTRUCTION ASSEMBLY NOTES ON SHEET A-4.1 FOR NOTES ON ALL WALL, ROOF, & FLOOR Level 1 Too Plate 9.09 BUILDER NOTE: THERE ARE NO STEPS FROM ENTRY TO HOUSE. THIS WAS DONE TO KEEP ROOF WITHIN 25HEIGHT LIMITS AND FOR ACCESSIBILITY PURPOSES LINE OF AVERAGE FINISH GRADE (ELEV.175.74') LINE OF LEVEL 1 FLOOR (ELEV.175.56) Level 1 0.00 �— LINE OF TOP OF FOUNDATION WALL (ELEV.175.36') — FINISH FLOOR ELEVATIONS BUILDER TO CONFIRM ALL FINISH FLOOR ELEVATIONS WITH SITE GRADING PLAN PRIOR TO ANY CONSTRUCTION RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson -Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Pro-ject Address 840 Daley St. Edmonds, WA Drawings for Conditional Use Permit for ADU 4-19-2023 Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 C1---J- IrZI-1- East and West Elevations 77543 REGISTERS 7 1ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 08/15/21 A-3,02 Drawn By Author East and West Elevations Scale 1 /4" = 1'-0" Sheet Plot Date 7/17/2023 1:55:13 PM wwwkarlColsonArchitect.com R403.3.6DUCTS BURIED WITHIN CEILING INSULATION. ROOF SHINGLES UNDERLAYMENT PREPRIMING AND PAINTING OF WHERE SUPPLY AND RETURN AIR DUCTS ARE PARTIALLY OR COMPLETELY BURIED IN CEILING INSULATION, SUCH DUCTS SHALL COMPLY WITH ALL OF THIS REAR FACING CENTER ROOF HAS A SLOPE OF 3-in-12 AND WILL BE THE FOLLOWING: EXTERIOR WOOD SURFACES 1 1.13HE SUPPLY AND RETURN DUCTS SHALL HAVE AN INSULATION RNALUE NOT LESS THAN R-8. REQUIRED TO HAVE A ROOFING SHINGLE UNDERLAYMENT MEMBRANE 2. 2.AT ALL POINTS ALONG EACH DUCT, THE SUM OF THE CEILING INSULATION RNALUE AGAINST AND ABOVE THE TOP OF THE DUCT, AND AGAINST BELOW SHINGLES. SEE ROOF PLAN FOR LOCATION OF THIS ROOF. ROOF SLOPE & OVERHANG ANY NATURAL WOOD SIDING OR WOOD TRIM @ EXTERIOR F AND BELOW THE BOTTOM OF THE DUCT, SHALL BE NOT LESS THAN R-19, EXCLUDING THE RNALUE OF THE DUCT INSULATION. ROOF RIDGE VENTS SEE ROOF PLAN FOR ALL ROOF SLOPE SHALL BE PRE -PRIMED BY PAINTER OR SUPPLIER AT ALL ) eA EXCEPTION: SECTIONS OF THE SUPPLY DUCT THAT ARE LESS THAN 3 FEET (914 MM) FROM THE SUPPLY OUTLET SHALL NOT BE REQUIRED TO SEE ROOF PLAN FOR ALL RIDGE VENT LOCATIONS & ROOF VENT CALCULATIONS AND OVERHANG INFORMATION (TYP) COMPLY WITH THESE REQUIREMENTS. SIDES BEFORE INSTALLATION AND SHALL BE PAINTED W/ R403.3.6.1 EFFECTIVE RNALUE OF DEEPLY BURIED DUCTS. SEPARATION WALLS: DARK SHADED WALLS INDICATE ONE -HOUR FIRE RATED ROOF TRUSS SEPARATION WALLS wl2 x 6 STUD BETWEEN RESIDENCE & A.D.U. (TYP). PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. EXTERIOR PAINT AS SELECTED BY OWNER. WHERE USING A SIMULATED ENERGY PERFORMANCE ANALYSIS, SECTIONS OF DUCTS THAT ARE: INSTALLED IN ACCORDANCE WITH SECTION R403.3.6; HEIGHT OF SEPARATION WALLS WITH 7" RAISED HEEL HEIGHTS. LOCATED DIRECTLY ON, OR WITHIN 5.5 INCHES (140 MM) OF THE CEILING; SURROUNDED WITH BLOWN -IN ATTIC INSULATION HAVING AN RNALUE OF ALL ONE -HOUR RATED STUD WALLS (AT UPPER LEVEL) BETWEEN RESIDENCE SEE STRUCTURAL DRAWINGS. TOP OF ROOF TRUSS RIDGE ALL EXTERIOR WOOD TRIM SHALL HAVE SMOOTH SURFACE R-30 OR GREATER AND LOCATED SUCH THAT THE TOP OF THE DUCT IS NOT LESS THAN 3.5 INCHES (89 MM) BELOW THE TOP OF THE INSULATION, SHALL BE CONSIDERED AS HAVING AN EFFECTIVE DUCT INSULATION RNALUE OF R-25. AND ACCESSORY DWELLING UNIT SHALL EXTEND TO UNDERSIDE OF ROOF TRUSS LAYOUT SHOWN ISCHEMATIC ONLY. Carl J. Colson - Architect SHEATHING. SEE SHEET A-4.3 FOR DETAILS REFER TO ROOF PLAN & EXTERIOR ELEVATIONS TOP OF ROOF TRUSS RIDGE � TOP OF ROOF TRUSS RIDGE FOR ROOF DESIGN THAT INCLUDES GABLES, HIPS, OR OVERFRAMED AREAS. PLLC 0 - 0 cm I?2502 Washington Blvd, ROOF CONSTRUCTION SEE CONSTRUCTION PROVIDE PLASTIC BAFFLES Anacortes, WA 98221 00 ASSEMBLY NOTES BELOW FOR r ABOVE ALL BIRDBLOCK I� INFORMATION VENTS @ ALL EAVES TO 425-773-4392 � Q ALLOW FOR PROPER � BIRDBLOCK VENTS @ALL VENTILATION (TYP) VENTILATION wwwCarlColsonArchitect. com EAVES EAVES (TYP) 10 RAISED HEEL @UPPER �0 12 ROOF @ W7M7 LEVEL ROOF TRUSSES (TYP) Commercial & Residential Level 2 Top Plate M-G4QRRD DF - 18.76 J INSCISSOR _ _ Level 2 Top Plate 18.76 TRUSSES (TYP) co ATTIC ACESS HATCHES N r Architecture TRUSS COMPANY &FRAMER M RAISED HEEL HEIGHT ROOF TRUSSES @ 24" O.C. (TYP). ROOF OVERFRAME GIRDER TRUSS OR SEE FLOOR PLAN FOR ATTIC ACCESS HATCH o PAINTED 2 x 8 CEDAR FASCIA SCISSOR TRUSSES ARE 10.5" RAISED HEEL @ BOARD. PRE -PRIMED @ ALL LOCATED ABOVE MASTER ZD UPPER LEVEL ROOF SEE STRUCTURAL DRAWINGS SEE ROOF PLAN, STRUCTURAL & TRUSS BEAM. SEE STRUCTURAL LOCATION BIRDBLOCK VENTS @ALL -READERS @ EXT. DOORS & WINDOWS EAVES (TYP) TangResidence SIDES (TYP) BEDROOM & FAMILY ROOM ONLY TRUSSES (TYP) R-49 INSULATION @ ATTIC SPACE (TYP) MANUFACTURERS DRAWINGS ALL HEADERS @ EXTERIOR WALLS SHALL BE PRIMED AND PAINTED SMOOTH 17' 8" DRAWING FOR GABLE ROOF OVERFRAME @ SEPARATION WALLS CEILING AT ATTIC INSULATED PER CODE STANDARDS (TYPICAL) Project Address PLYWOOD SHEATHING AT AREA THIS AREA ` DARK SHADED WALLS SEE ASSEMBLY UPPER LEVEL WINDOW HEAD r OF EXPOSED EAVES (TYP) INDICATE WALLS w/ 2 x 6 NOTES BELOW FOR SEE UPPER LEVEL FLOOR PLAN FOR WINDOW 00 ® 840 Daley St. HVAC SUPPLY DUCT IN TRUSSES UPPER LEVEL FRAMING SYSTEM SHADED WALLS INDICATE WALLS w/ 2 x STUD FRAMING wl 1/2" TYPE X CEILING GYPSUM BOARD @ EACH CONSTRUCTION � HEAD HEIGHTS (TYP) EXTERIOR WALL Edmonds, WA 6 STUD FRAMING (TYP) SEE SHEET A-2.5 FOR LOCATION PARALLEL CHORD WOOD FLOOR TRUSSES SIDE FOR SEPARATION SEE WALL CONSTRUCTION ASSEMBLY NOTES SEE WINDOW SCHEDULE SHEET FOR OF HVAC SUPPLY DUCT CHASES @ UPPER LEVEL ONLY. (FRAMING SHOWN WALLS BETWEEN RESIDENCE ' BELOW FOR EXTERIOR WALL CONSTRUCTION ALL INTERIOR & EXTERIOR DOOR & IN UPPER LEVEL TRUSS FRAMING IS SCHEMATIC ONLY - SEE STRUCTURAL ,' AND ACCESSORY DWELLING WINDOW TRIM INFORMATION DRAWINGS FOR SIZE, FRAMING LAYOUT, ' UNIT. SEE PLANS FOR GARAGE CEILING INSULATION AND SUPPORTING BEAMS AT THIS AREA) SEPARATION WALLS (TYP) INSTALL R-49 BATT INSULATION @ GARAGE CEILING Family Room Family Room Vestibule Laundry Room ADU Bathroom-,' ADU Bedroom Jk Level 2 _ _ ' ' _ _ _ Level 2 Project Client & Project Applicant 10.67 00 10.67 _Le 1 Top Plate _ _ _ Level 1 Top 91 09 Peter & Jia Tang 1 8 Bedroom #3 11 811 Garage 648 Bell St. VAC CHAS Kitchen Pantry Powder Room VAC CHAS9 HVAC SUPPLY DUCT IN TRUSSES OVER GARAGE FOR SINGLE FAMILY Edmonds, WA 98020 ONE HOUR SEPARATION FLOOR/ CEILING ASSEMBLY RESIDENCE 206-372-2584 INTERIOR WALL SEE SHEET A-4.3 FOR ONE HOUR FLOOR / CEILING SEE SHEET A-2.5 FOR LOCATION OF HVAC SUPPLY DUCT CHASES IN UPPER Sheet Title SEE WALL CONSTRUCTION ASSEMBLY BETWEEN RESIDENCE CEILING & ADU FLOOR LEVEL TRUSS FRAMING ASSEMBLY NOTES BELOW CRAWL SPACE BARRIER @ VENTED CRAWL SPACE FOR INTERIOR WALL � �ATTACHED VAPOR BARRIER.AS SPECIFIED IN NOTES ON THIS PAGE. INSTALL DRAFTSTOPS IN FLOOR / CEILING ASSEMBLIES SO ' THAT CONCEALED SPACE DOES NOT EXCEED 1,000 S.F. THIS CHASE NOT REQUIR GARAGE GARAGE I LIVING SPACE SEPARATION IN TRUSSES OVER ADU GARAGES SHALL BE SEPARATED FROM THE RESIDENCE / OR ADU GARAGE. SEE SHEET A-2.5 Building Section CONSTRUCTION AND ITS ATTIC AREA BY NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EXTEND UP SIDE WALLS A MIN. OF 12" FOR LOCATION OF SUPPLY EQUIVALENT APPLIED TO THE GARAGE SIDE. GYPSUM BOARD SHALL BE00 ` ` FOUNDATION WALL FOOTINGS DUCT CHASES T INSTALLED ON WALLS WITH FASTENER SPACING NOT TO EXCEED 8 INCHES r CRAWL SPACE ACCESS SEE FLOOR PLAN FOR CRAWL SPACE ACCESS HATCH ` ` SEE STRUCTURAL DRAWINGS FOR WIDTH & DEPTH ® OF ALL FOUNDATION WALL & WALL FOOTINGS ON CENTER. GYPSUM BOARD INSTALLED ON THE CEILINGS SHALL BE °' (TYP) INSTALLED PERPENDICULAR TO THE FRAMING WITH FASTENER SPACING NOT FOUNDATION WATERPROOFING FLOOR CONSTRUCTION CRAWL SPACE ACCESS TO EXCEED 7 INCHES. INSTALL A FLUID APPLIED OR MEMBRANE CRAWL SPACE CLEARANCE SEE ASSEMBLY NOTES BELOW BELOW STAIRS SHEET WATERPROOFING @ EXTERIOR FACE PER DRAWING FOR FLOOR CONSTRUCTION SEE FLOOR PLANS FOR ' ' OF ALL CONCRETE FOUNDATION WALLS (TYP) OVER UNHEATED AREA CRAWL SPACE ACCESS R-10 RIGID INSULATION OVER CRAWL SPACE VAPOR BARRIER @ PERIMETER FOUNDATION WALL HABITABLE ROOMS ABOVE GARAGES SHALL BE SEPARATED BY NOT LESS THAN 5/8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT APPLIED TO THE RAISED FOUNDATION WALL (TYP). SEE HATCH ' R-10 RIGID INSULATION OVER VAPOR BARRIER.AS SPECIFIED GARAGE CEILING, AND FASTENED WITH MINIMUM 17/8 INCHES 6D COATED FOUNDATION PLAN FOR DETAIL. FLOOR INSULATION IN NOTES ON THIS PAGE. EXTEND UP SIDE WALLS TO ` NAILS OR EQUIVALENT DRYWALL SCREWS WITH SPACING NOT TO EXCEED 6 FLOOR JOISTS TO HANG OFF FROM R-38 INSULATION @ FLOORS ' ' ` UNDERSIDE OF FLOOR SHEATHING AND SEAL JOINT INCHES. ALL STRUCTURE SUPPORTING THE FLOOR/CEILING SEPARATION 00 7543 M SIDES OF FOUNDATION WALLS (TYP) OVER UNHEATED SPACES ASSEMBLY SHALL BE PROTECTED BY NOT LESS THAN 1/2-INCH GYPSUM REGISTERS 0100 Level 1 - N - - BOARD -OP Gnhz�al�NT- - - ARCHITECT W. � WIN i 0.20F FLOOR FRAMING FOUNDATION PERIMETER DRAINAGE SYSTEM ,.; ,.;�.:;��.:.," � I 0.20 CARL J. COLSON THIS BEAM &POST ALIGN w/ STRUCTURAL FRAMING SUPPORT BEAMS, POSTS, &FOOTINGS FRAMING IS SCHEMATIC ONLY. SEE STRUCTURAL DRAWINGS FOR ALL - TIE DRAINS INTO DRAINAGE SYSTEM FOR SEE STRUCTURAL DRAWINGS FOR ALL LOCATIONS SHOWN ARE APPROXIMATE. WALL BEYOND SEPARATING I ii �� CONTRACTOR NOTE S ATE OF WASHINGTO STORM WATER INFILTRATION AREAS PER Vented FLOOR JOIST SIZES, SPACING, SUPPORT POSTS, AND POST FOOTINGS - FLOOR FRAMING AND SUPPORT SEE STRUCTURAL DRAWINGS FOR CIVIL ENGINEERING DRAWINGS (TYP) VAPOR BARRIER POSTS, FOUNDATION WALLS & LOCATIONS, BEAM SIZE, POST SIZE, & Crawl Space GARAGE FROM LIVING SPACE. SEE STRUCTURAL DRAWINGS �� TOP & BOTTOM OF FOOTING a I I ELEVATIONS ARE APPROXIMATE CLASS 1 VAPOR BARRIER TO BE INSTALLED IN ENTIRE CRAWL SPACE - n� FOOTINGS IN CRAWL SPACE (TYPICAL) FOOTING �� SIZE (TYP) & SHALL EXTEND UP �� 12 @ PERIMETER FOUNDATION WALLS J ONLY. ACTUAL ELEVATIONS WILL �� �- Issued For Permit: 04-05 - 2023 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - � DEPEND UPON FINISH GRADE & .a� DEPTH OF BEARING SOIL (TYPICAL @ - ALL FOOTINGS) III III III " I " ' -III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III III II Document Set Type: EXTERIOR FOOTING DRAINS Revision Schedule FOOTING DRAINS IN FILTER FABRIC SOCK AND GRAVEL FILL - FILTER FABRIC @ TOP & SIDE OF GRAVEL FILL. Tang Residence East - West Building Section Rev. CONNECT TO DRAINAGE SYSTEM PER CIVIL DRAWINGS (� 1'-0�� # Date Description CONSTRUCTION ASSEMBLY NOTES WALL ASSEMBLY NOTES ROOF ASSEMBLY NOTES FLOOR, STAIRS, GUARDRAILS PORCH & DECK CONSTRUCTION HEATING / PLUMBING NOTES GARAGE REQUIREMENTS PORCH AND UPPER PORCH SEE NOTES ABOUT MOLD, PRESSURE TREATED WOOD AND FASTENERS ON SHEET A-1.2 ROOF /ATTIC VENTILATION SEE ELECTRICAL PLAN, VENTILATION NOTES, & AIR QUALITY NOTES ON OCCUPANCY SEPARATION FIRE RATED ASSEMBLIES BIRD BLOCK VENTS @ ALL EAVES AND RIDGE VENTS AT LOCATIONS AS SHOWN ON FLOORS / CEILINGS UPPER PORCH SHEET A-2.3 FOR ADDITIONAL HVAC INFORMATION AND REQUIREMENTS OCCUPANCY SEPARATION BETWEEN GARAGE AND LIVING SPACE REFER TO SHEET 2-1 AND NOTES BELOW FOR FIRE/OCCUPANCY SEPARATION ROOF PLAN. SEE ROOF VENT CALCULATIONS ON ROOF PLAN 1/300th ATTIC AREA GLUE 7/8" ADVANTECH SUBFLOOR (SCREWS @ 6" O.C. @ EDGES - 10" O.C. AT INTERMEDIATE FRAMING MEMBERS) OVER SCHEDULED FLOOR JOISTS OR LEVEL 2 UPPER PORCH SHALL BE SYNTHETIC WATERPROOF DECK ELECTRIC HEAT PUMP HEATING / COOLING SYSTEM 5/8" TYPE X G.W.B. (TYP) CEILINGS: 1 LAYER ON ALL TRUSSES AND TJI's (1 LAYER ON STICK FRAMING @ REQUIREMENTS BETWEEN GARAGE AND LIVING SPACE ROOF VENTILATION W/ 1/2 AT SAVE LINE AND 1/2 AT RIDGE VENTS. PROVIDE TRUSS - GLUE TO EACH JOIST. FLOOR LOAD: 10 PSF DEAD LOAD 40 PSF COATING (SELECTION & COLOR BY OWNER) OVER PRESSURE TREATED THISRESIDENCE HALL BE HEATED AND LED BY AN ELECTRIC HEAT PUMP S COO C C U 16" O.C. OR LESS) TYPICAL EXTERIOR WALL CONSTRUCTION CROSS VENTILATION. 1" MIN. AIR SPACE ABOVE INSULATION ABOVE PER SECTION 1505.3 MIN. 3 SQ. FT. PROVIDE WIND BAFFLE W/ 1" AIR SPACE ABOVE ATTIC LIVE LOAD. INSTALL 1/2" PTD. G.W.B. CEILING AT UNDERSIDE OF JOISTS. PYLYWOOD OVER PRESSURE TREATED FRAMING WOOD FRAMING. (SEE HEATING / COOLING SYSTEM. A WHOLE HOUSE EXHAUST FAN (W/ TIMER) SHALL BE INSTALLED IN LAUNDRY ROOM WALLS: 1 LAYER ON COMMON WALLS TO ROOF SHEATHING / 1 LAYER ON HARDIE-PLANK LAP SIDING (SMOOTH FINISH AND MATCHING CAULK) W/ 6" EXPOSURE INSULATION. EXTEND TO A POINT 12" VERTICALLY ABOVE INSULATION. INSTALL R-38 BATT INSULATION BELOW ADVANTECH SUBFLOOR OVER STRUCTURAL DRAWINGS FOR DECK FRAMING AND DECK SUPPORT POST INFORMATION) GENERAL CONTRACTOR AND HEATING SUBCONTRACTOR SHALL COORDINATE ALL WALLS TO SUPPORT PROTECTED CEILINGS DRAWING USE NOTIFICATION 2 HYTUDS @ DRAINABLE HOUSEWRAP OVER RAIN SCREEN OVER BENJAMIN O OVER OVER 1/2" EXT. PLYWOOD SHEATHING OVER 2x6 STUDS @ 16" O.C. W/ R 21 BATT TYPICAL ROOF CONSTRUCTION UNHEATED AREAS. SEE BUILDING SECTION FOR AREAS OF PARALLEL CHORD WOOD TRUSSES. LEVEL 2 UPPER PORCH SHALL HAVE A TOP -MOUNTED GUARDRAIL DUCT LAYOUT LOCATIONS AND ROUTING OF DUCTS PRIOR TO FRAMING PROCESS. ALL DUCTWORK SHALL BE LOCATED IN CONDITIONED SPACE POSTS AND BEAMS: 1 LAYER DOOR TO LIVING AREA: INSTALL 1-3/8" SOLID CORE WOOD DOOR WITH SELF This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and INSULATION AND 1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER SEALER CONTRACTOR SHALL INSTALL A 40 YEAR ASPHALT COMPOSITION SHINGLES w/ SEE OCCUPANCY SEPARATION NOTES FOR GARAGE CEILING GYPSUM WALLBOARD REQUIREMENTS. SYSTEM (36" HIGH ABOVE WALKING SURFACE) AND VERTICAL BALUSTERS SHALL BE PLACED SO THAT A 4"DIAMETER SPHERE WILL WATER HEATER CLOSER AND WEATHERSTRIP drawings as required b review of the Building Department in the g q Y g p (OR 260). SEE ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS. G COLOR AND MANUFACTURER SELECTION BY OWNER; NOT PASS BETWEEN BALUSTERS OR STRINGERS. SEE ELEVATION GARAGE INSULATION jurisdiction where this project is located. ANY NATURAL WOOD SIDING WOOD TRIM EXTERIOR SHALL BE PRE PRIMED AT ALL OVER OWENS CORNING PROARMOR 42-IN X 286-FT 1000-SQ FT SYNTHETIC STAIR / STEPS CONSTRUCTION DRAWINGS AND DECK DETAILS FOR ADDITIONAL INFORMATION. AN ELECTRIC HEAT PUMP WATER HEATER SHALL BE INSTALLED IN GARAGE. AT WALLS BETWEEN GARAGE AND HEATED SPACE, INSTALL 2x 6 STUD WALLS DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP SIDES (BEFORE INSTALLATION) AND PAINTED W/ EXTERIOR PAINT. ROOF UNDERLAYMENT OVER SHEATHING (AS SCHEDULED BY STRUCTURAL 1) MAXIMUM RISE SHALL BE 7-3/4": MINIMUM RUN SHALL BE 11 ": HEADROOM REFER TO FURNACE & WATER HEATER NOTES FOR INFORMATION (@ 16" O.C.) W/ R-21 BATT INSULATION. AT CEILINGS BETWEEN GARAGE AND APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF SEE ELEVATION DRAWINGS FOR SPECIFIED SIDING MATERIALS. ENGINEER OVER SCHEDULED FRAMING MEMBERS. ALL ROOF VALLEYS SHALL HAVE A 36" WIDE CONTINUOUS STRIP OF GRACE MINIMUM SHALL BE 6-8": WIDTH SHALL BE 36"MINIMUM. REFER TO FLOOR ENTRY PORCH, REAR PORCH, AND PATIO ALL PATIOS AND PORCHES SHALL BE CONSTRUCTED WITH THE PLUMBING NOISE CONTROL &INSULATION HEATED AREAS ABOVE, INSTALL R-38 BATT INSULATION BETWEEN SCHEDULED JOISTS, INSTALL R-10 RIGID INSULATION BELOW SLAB AT HEATED AREAS. TYPICAL INTERIOR WALL CONSTRUCTION SELECT 25 MIL PEEL-N-STICK MEMBRANE (EQUALLY SPACED AT CENTERLINE PLANS FOR SCHEDULED STAIR WIDTH, RISER DIMENSIONS, AND TREAD DIMENSIONS. FOLLOWING MATERIALS: NOISE CONTROL DUCTS IN GARAGE THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless LEVEL 4 DRYWALL FINISH: 1/2" PAINTED GYPSUM WALLBOARD GWB AT EACH SIDE OF (GWB) OF ROOF VALLEY) AND DARK BRONZE METAL VALLEY FLASHING REFER TO ROOF PLAN FOR ALL STRUCTURAL FRAMING SIZES. 2.) HANDRAILS TO HAVE ENDS RETURNED TO WALL OR NEWEL POST AND PATIO SURFACE: 4" CONCRETE SLAB ON COMPACTED GRAVEL/FILL WITH ALL PLUMBING SUPPLY AND DRAIN LINES SHALL BE WRAPPED WITH FOAM PIPE INSULATION. HOT WATER LINES SHALL BE WRAPPED W/ R-5 INSULATION DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS authorized by Client. During Construction Phase, the Clients General WALL W/ 2x4 STUDS @ 16" O.C. USE 1/2" WATER RESISTANT GYP. BD. @ALL KITCHEN, REFER TO STRUCTURAL GENERAL NOTES FOR PANEL NAILING INSTRUCTIONSFINISH PLACED MINIMUM 34", MAXIMUM 38" ABOVE TREAD NOSING. THE HAND GRIP PORTION HANDRAILS SHALL BE NOT LESS THAN 1-1/2" SURFACE SELECTED BY OWNER. SEE FLOOR PLAN FOR INTERIOR PLUMBING WALLS SHALL BE INSULATED WITH SOUND BATT SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF Contractor (Builder) or Developer shall be responsible for ensuring that all BATHROOM, AND LAUNDRY ROOM LOCATIONS. USE (CEMENT AND ATTACHMENT INFORMATION ON ALL STRUCTURAL MEMBERS. N -S NOR MORE THAN 2" IN CROSS -SECTIONAL DIMENSION OR THE SHAPE SHALL L CONTROL JOINT LOCATIONS. INSULATION. A MINIMUM NO.26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL AND Construction Personnel of the General Contractor and all Subcontractors SHOWERS, AND TILE L BACKERBOARD) BACKING BEHIND ALL TUBS, SHOWERS, AND TILE LOCATIONS REFER TO ROOF FRAMING PLAN FOR ALL HOLD DOWN TIES OR CLIPS. ROOF PROVIDE AN EQUIVALENT GRIPPING SURFACE. THE HANDRAIL GRIP PORTION FI R E B L KI N PLUMBING LINES SHALL HAVE NO OPENINGS INTO THE GARAGE. are supplied with all Approved and most current documents. GARAGE WALL CONSTRUCTION OCCUPANCY SEPARATION NOTES FOR WALL AND CEILING CONSTRUCTION LIVE LOAD PER STRUCTURAL DRAWINGS. BRACE WALLS PER 2015 INTERNATIONAL RESIDENTIAL CODE OF HANDRAILS SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF NET LESS FIREBLOCK CONSTRUCTION PEX SUPPLY (WATER HOT AND COLD), ABS FOR VENT, AND CAST IRON FOR ADDITIONAL INSULATION ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior (SEE BETWEEN GARAGE AND LIVING AREAS ROOF GUTTER CONSTRUCTION THAN 1-1/2" BETWEEN THE WALL AND HANDRAIL. 1. INSTALL FIREBLOCKING MADE OF MATERIALS AS ALLOWED BY THE 2015 WASTE THAT RUNS THROUGH LIVING SPACE. ABS WASTE IN BASEMENT SLAB OR CRAWLSPACE. REQUIREMENTS 5/8" PTD. TYPE X GYPSUM WALLBOARD (FIRETAPED) AT INTERIOR FACE OF WALL WITH 2x4 OR 2x6 STUDS @ 16" O.C.. EXTERIOR FACE OF WALL SHALL BE PRE- REFER TO ROOF PLAN FOR NOTES ON ROOF GUTTERS AND DOWNSPOUTS. 4) WHEN DECKS, LANDING OR PORCHES ARE MORE THAN 30" ABOVE GRADE, PROVIDE GUARDRAILS NOT LESS THAN 36" HIGH WITH INTERMEDIATE EDITION OF THE 2018 INTERNATIONAL RESIDENTIAL CODE. DRYER VENTING approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an PRIMED AND PAINTER CEDAR OR HARDIE-PLANK HORIZONTAL LAP SIDING OVER CEILINGS AT ATTIC SPACE MEMBERS SPACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. DECKS ACCESSIBLE ONLY TO INDIVIDUAL UNITS OR AREAS ( 2. PROVIDE FIREBLOCKS AROUND VENTS AND PIPES AND AT VERTICAL OPENINGS WHERE EXHAUST FAN DUCTS ARE ROUTED TO ROOFTOP DRYER VENTING - W.S.E.C. SEC. M1502.4.5 STATES, "WHERE THE EXHAUST DUCT IN ADDITION TO INSULATION REQUIREMENTS NOTED ELSEWHERE IN THIS SET OF DRAWINGS, THE FOLLOWING REQUIREMENTS FROM THE instrument of service shall remain the property of Carl J. Colson- Architect FORTIFIBER WEATHERSMART DRAINABLE OR BENJAMIN OBDYKE HYDROGAP DRAINABLE HOUSEWRAP OVER 1/2" EXT. PLYWOOD SHEATHING. REFER TO BUILDING ELEVATIONS 1/2" PTD. GWB OVER MEMBRAIN SMART VAPOR RETARDER VAPOR BARRIER OR WITHIN INDIVIDUAL UNITS MAY USE 36" HIGH GUARDRAILS). EXHAUST VENTS. PROVIDE STRAPPING AS REQUIRED BY CODE. IS CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE INDENTIFIED ON A PERMANENT 2018 W.S.E.C. SHALL BE FOLLOWED: PLLC and are solelyfor the use on this project Only.These files, drawings, p 1 g ' FOR LOCATION OF CULTURED STONE VENEER TO BE APPLIED IN LIEU OF WOOD SIDING. BENJAMIN MOORE'S SUPER SPEC LATEX VAPOR BARRIER PRIMER SEALER 260 ALL STAIRS SHALL HAVE SOLID RISERS EXTERIOR STAIR TREADS AND ( 3. PROVIDE AND INSTALL FIREBLOCKS AT ALL LOCATIONS IDENTIFIED IN LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT. OF THE 1 INSULATED HEADERS ALL VOIDS FILLED TO MIN. R-10. ) ideas, or designs may not be tramsmitted electronically without express g Y Y p WALL ANCHORING OVER SCHEDULED CEILING JOISTS @ 24" O.C. W/ R-49 BATT INSULATION. RISERS SHALL BE TREX TYPE SYNTHETIC SURFACES). 2018 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE AND AS EXHAUST DUCT CONNECTION". 2) NO WALL STACKS IN EXTERIOR WALL CAVITIES permission of Architect. They are not be used by the client or any other UNLESS SHOWN OTHERWISE ON STRUCURAL OR FRAMING DRAWINGS, BOLT APPROVED CRAWL SPACE NOTES GUARDRAILS ARE TO BE DESIGNED TO RESIST A 200 LB. CONCENTRATED FOLLOWS: A) IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS AT THE INSTALL DOWN VENT METAL DRYER BOX BEHIND DRYER AND EXTEND METAL 3) RETURN AIR MUST BE DUCTED (NON -DUCTED JOIST BAYS NOT ALLOWED). art or emit on other ro'ects, in whole or art, or as an extension to this party Y projects, p project except by agreement in writing with appropriate financial MUD SILL (PER SEC 2317.4 TO TOP OF CONC. WALL W/ 5/8" x 10" ANCHOR BOLTS @ 4'-0" O.C. LOAD ON THE TOP RAIL AND 50 PSF ON ALL GUARDRAIL INFILL COMPONENTS. CEILING DUCT TO SIDEWALL OF HOUSE.. SEE UPPER FLOOR PLAN FOR NOTES. 4) PER SELECTED ENERGY CREDIT OPTION, WINDOWS SHALL HAVE A U compensation to Carl J. Colson -Architect PLLC. & V-0" O.C. FROM EACH SPLICE PER SEC 1806.5. PROVIDE TERMITE SHIELD AT MUDSILL CRAWL SPACE VAPOR BARRIER AND FLOOR LEVELS AT AT 10 FOOT INTERVALS BOTH VERTICAL AND SPRINKLER SYSTEM REQUIRED VALUE OF 0.28, R-38 INSULATION IN FLOORS OVER UNHEATED AREAS, Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O WALL &CEILING PENETRATIONS THIS CRAWL SPACE SHALL HAVE A CLASS 1 VAPOR BARRIER. HORIZONTAL. B) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND THIS RESIDENCE IS REQUIRED TO BE SPRINKLERED PER CITY OF EDMONDS. 5) ALL PLUMBING WALLS SHAVE HAVE SOUND INSULATION AND ALL PLUMBING LINES SHALL BE WRAPPED W/ FOAM PIPE INSULATION Project Number REFER TO 2018 INTERNATIONAL RESIDENTIAL CODE FOR REQUIREMENTS FOR ALL VAPOR BARRIERS SHOULD BE SECURED TO THE GROUND FLOOR, COVERING ANY EXPOSED DIRT AND EXTENDING UP PERMITER FOUNDATION WALLS FOR HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. INSULATION R-VALUES PENETRATIONS THRU RATED WALLS, FLOOR/CEILING, AND CEILING/ROOF. A MINIMUM OF 12. JOINTS MUST OVERLAP NO LESS THAN 6 INCHES, AND ALL " A-4,0 1 SEAMS MUST BE TAPED C) IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND RES U B Sheet Issue Date BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE PER WASHINGTON STATE ENERGY CODE , THE INSULATION VALUES ARE R 21 FOR 04/22/13 RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED. WALLS, R-38 FOR FLOORS OVER UNHEATED SPACE, AND R-49 IN ATTIC SPACE. Jul 19 2023 Drawn By Author D) IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES INSULATION CERTIFICATE CILOPM ETSERVI BuildingSection AND DEVELOPMENT SERVICES SIMILAR OPENINGS THAT AFFFORD A PASSAGE FOR FIRE AT CEILING AND BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR DEPARTMENT Scale FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. E) AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR RESIDENTIAL CONSTRUCTION" WITHIN T OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. As indicated Sheet Plot Date 7/17/2023 1:55:47 PM FACTORY BUILT CHIMNEYS. www.CarIColsonArchitect.com For 36"- and 42"-Tall Guard Posts As an alternative code -compliant solution for attaching wood guard posts without the use of typical hardware and through -bolts, the guard posts and the framing elements can be fastened with Strong -Drive° SDWS Timber screws. The SDWS Timber screws are code report listed in IAPMO UES ER-192. The solutions below have been tested and verified for 36"-tall guard posts constructed with DFL, HF and SP framing. These solutions have also been tested and verified for 42"-tall guard posts constructed with DFL and SP framing only 0.220" 0.75" �! Thread length - Length Strong -Drive SDWS TIMBER Screw (SDWS2250ODB, SDWS2280ODB) Note: For this installation, it is imperative that only approved fasteners are used and installed per Simpson Strong Tie details. Test results have shown that generic fasteners do not provide sufficient withdrawal resistance, pull -through resistance or shear strength. ROOF GABLE END WALL OVER GABLE ROOF TRUSS PTD. METAL DRIP EDGE FLASHING HARDIE TRIM (SELECTION BY OWNER) OVER 1 x 10 HARDIE TRIM PTD. METAL DRIP EDGE FLASHING UVrn ue� rLrVVvvu SHEATHING OVER 2 x 6 WALL BELOW TOP PLATE UPPER PORCH COLUMN BEYOND 8� 51/2" 6 x 6 POST IN COLUMN a a • a• � �� I UPPER PORCH COLUMN BEYOND • � I COLUMN CENTERLINE Internal Guard Post Installations Using PRIMED & PAINTED SYNTHETIC 2 x 6 TOP CAP W/ EQ. SLOPES TO DRAIN TO SIDES PRIMED & PAINTED CEDAR 2 x 4 SUB -RAILING. 44 post blocking Deck joist I5" NAIL TO PORCH COLUMN BEYOND \44 Z--, / ..,�_ PRIMED & PAINTED CEDAR 1 x 4 EA. SIDE 8" 8" _ PRIMED & PAINTED CEDAR 2 x 2 t/ BALUSTERS SPACED SO TO PREVENT 5" PASSAGE OF 4" DIA. SPHERE. BALUSTER END -NAILED TO CEDAR 2 x 4 SUB -RAILING Band joist (nominal 2x8) SDWS22800DB, designated as SDWS22500DB, 8" throughout designated as 5" throughout PRIMED &PAINTED CEDAR 4 x 4 GUARDRAIL POSTS. SEE FLOOR PLAN 4Y4 hlnckinn iY hlnrkinn tun FOR LOCATIONS O O O O O O - Rim joist (nominal 2x8) 0 M Plan View Showing Details of Four Connections Using Strong -Drive SDWS Timber Screws (other connection hardware not shown for clarity) PTD. METAL DRIP EDGE FLASHING Upper Porch Guardrail Post Attachment w/ Simpson Connectors 1 x 4 CEDAR TRIM OVER 2 x 12 HARDIE TRIM 5/4 x 6 BLOCKING RIM JOIST 1 x 6 CEDAR TRIM OVER 1 x BLOCKING 1 x 10 CEDAR TRIM PTD. METAL DRIP EDGE FLASHING. COORDINATE DETAIL W/ OWNER 1 x 6 CEDAR LEVEL 1PORCH COLUMN BEYOND. SEE COLUMN DETAIL ON SHEET A-4.2 I 61/2" 1 r I I i J--MINI I 5 3/4 FASTENERS: ALL SCREWS AND NAILS SHALL BE GALVANIZED PRIMED & PAINTED CEDAR 1 x 4 EA. SIDE. CUT TOP SLOPE TO DRAIN AS SHOWN PRIMED & PAINTED CEDAR 1 x 4 TO WRAP BOTTOM OF POST SLOPE DECK 1/4" PER FT. _ — BOLT 4 x 4 GUARDRAIL POST TO 2 x 10 BLOCKING & RIM JOIST (PER GUARDRAIL POST ANCHOR DETAIL ON THIS SHEET) BETWEEN ADJACENT JOISTS @ GUARDRAIL POST LOCATIONS. 717 THESE 2 BLOCKS OCCUR ONLY AT \ GUARDRAIL POST LOCATIONS 2 x 6 CEILING JOISTS @ 24" O.C. 1 x 2 TRIM @ PORCH PERIMETER 3/4" WIDE SCREENED VENT @ OUTSIDE N PERIMETER OF PORCH 1 x 3 @ OUTSIDE PERIMETER OF PORCH TOP OF THIS CEILING TO ALIGN W/ LEVEL 1 TOP PLATE & UNDERSIDE OF GIRDER TRUSS BELOW OVERHANGING MASTER BEDROOM WEST WALL. REFER TO STRUCTURAL DRAWINGS PRIMED AND PAINTED TONGUE AND GROOVED BOARDS ON 1 x 4 STRAPPING (AT BOTTOM OF ROOF TRUSSES) TO ENSURE ALL CEILING BOARDS RUN IN A NORTH - SOUTH DIRECTION AT UPPER LEVEL PORCH. (1 x 4 STRAPPING NOT SHOWN IN BOTTOM OF BEAM WRAP @ SAME ELEVATION @ ALL SIDES OF UPPER PORCH UPPER LEVEL PORCH LEVEL 2 FLOOR LEVEL WATERPROOF DECK COATING ON PRESSURE TREATED 3/4" PLYWOOD DECKING L — — — — — — — — — — — — PORCH FLOOR JOISTS PER STRUCTURAL DRAWINGS LEVEL 1 TOP PLATE LEVEL VENTED PORCH CEILING PRIMED AND PAINTED TONGUE AND GROOVED BOARDS ON 1 x 4 STRAPPING (AT BOTTOM OF ROOF TRUSSES) TO ENSURE ALL CEILING BOARDS RUN IN A NORTH - SOUTH DIRECTION AT UPPER LEVEL PORCH. (1 x 4 STRAPPING NOT SHOWN IN THIS DETAIL) BOTTOM OF BEAM WRAP @ SAME ELEVATION @ ALL SIDES OF UPPER PORCH LOWER LEVEL PORCH Section thru Upper Porch Framing & Guardrail 1 1/2 to = 1 '-0" Tnrnl r c`TI rnc%.../ 1/211 PLYWOOD 3 FRAME SIZE 3 3 FRAME SIZE 3 " 5 1/2" ROUGH OPENING 5" ROUGH OPENING 5 1/2" Window Jamb Framing at Double or Triple Window Grouping - Window Jamb Framing Detail @ Multiple Windows 4 3tt 1, O,t PRIMED & PTD. 1x CEDAR WRAPPING ROOF SUPPORT BE CONCRETE PORC SLOPE 1/4" PER FT FROM ENTRY D00 SCHEDULE ROOFING. SEE ROOF PLAN FOR ROOF SLOPE. SEE SHEET A-4.1 FOR ROOFING TYPE INFOMATION METAL DRIP EDGE FLASHING @ ALL ROOF EDGES 1 x 2 PRIMED & PTD. CEDAR TRIM (WRAPPED) @ TOP OF COLUMN PAINTED PORCH COLUMN LINE OF STRUCTURAL WOOD POST. SEE STRUCT. DWGS. FOR SIZE & CONNECTION DETAILS. SEE PLAN DETAIL FOR LOCATION OF STRUCTURAL POST 1x PRIMED A & PTD. CEDAR TRIM OVER WEATHER BARRIER MEMBRANE OVER 1/2" EXTERIOR PLYWOOD SHEATHING OVER STRUCTURAL COLUMN. PRIMED & PTD. 2x6 CEDAR COLUMN BASE TRIM W/ CHAMFERED EDGE @ TOP SLOPING CONCRETE ENTRY WALK REFER TO STRUCTURAL DRAWINGS FOR ALL COLUMN FOOTING DETAILS Front & Rear Porch Column Elevation 1/2 = 1 '-0" COVERED PORCH — -- --- a m � m 3/4 1/2 HOUSE INTERIOR I 1/2" PLYWOOD I I 1 ECM WI AP SIDING CORNER BOARD BEAM 1I 1x PRIMED A & PTD. CEDAR 1 TRIM OVER WEATHER 8" i BARRIER MEMBRANE OVER I 1/2" EXTERIOR PLYWOOD SHEATHING OVER 6 x 6 TREATED WOOD STRUCTURAL COLUMN. bo PRIMED & PTD. 2x6 CEDAR COLUMN BASE TRIM W/ CHAMFERED EDGE @ TOP Porch Column Porch Column Detail at Wall Intersection 2 1 1 /2" = 1 '-0" BUILDER NOTE: / THIS JAMB FRAMING DETAIL APPLIES TO WINDOWS @ ALL LEVELS. THIS DETAIL IS INCLUDED TO SHOW STUD LOCATIONS @ WINDOWS. RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Title Exterior Details 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O 1Project Number Sheet Issue Date —4,02 02/16/23 Drawn By Author Exterior Details Scale As indicated Sheet Plot Date 7/17/2023 1:56:20 PM www.CarlColsonArchited.com DOUBLE HUNG WINDOW W/ PTD. MDF TRIM PER WINDOW INTERIOR TRIM DETAIL PTD. MDF VERTICAL SUPPORT - FULL DEPTH OF SHELF (HOLD EDGE BACK FROM EDGE BAND) PTD. MDF CAP & WOOD TRIM MOLDING @ TOP OF BOOKCASE CABINETS AS SELECTED BY OWNER PTD. WOOD BASE TRIM LINE OF FINISH FLOOR EXTERIOR WALL EQUAL 61- 41/2" r � I I WINDOW @ THIS AREA NOT SHOWN r EDGE OF CABINETS BELOW EQ. PER FIREPLACE MANUF. EQ. 6'-0" FIREPLACE PLAN BUILDER NOTE: PRIOR TO FRAMING FIREPLACE ENCLOSURE, BUILDER SHALL COORDINATE DIMENSIONS AND VENTING REQUIREMENTS W/ GAS FIREPLACE SELECTED BY OWNER co I I I 65" WIDE SCREEN TY. PROVIDE BLOCKING FOR TV BRACKETS r------------------------- I I I I I I I I I I I I co I I I I M I I I I I I I I I I I I L J z Q li U_ W 15' - 3 1 /2" Face of Stud to Face of Stud Y- Y- N - Y' Y' Y' Y' Y' Y-' Y' Y- Y- Y- Y- Y' Y' Y' Y' Y' Y" Y-' Y- Y- Y- Y- Y' Y' Y' Y' Y' Y- Y., Y- Y- Y- Y- Y' Y' Y' Y' Y' Y- l^' Y' Y- Y- Y' Y' Y' Y' Y' Y' Y- Y-' Y' Y- Y ALL INTERIOR WALL SURFACES (TOPS & R302.3 Two-family dwellings. SIDES) OF FIREPLACE ENCLOSURE SHALL Du.,elling units in two-family dwellings shall be separated from each other by wall and floor assemblies having not less than a 1-hour fire -resistance rating where tested in accordance with ASTNI E119, UL 263 or BE WRAPPED W/ 5/8" TYPE X GYP. BD. EQUAL Section 703.3 of the International Building Code Fire -resistance -rated flooCceiling and wall assemblies shall extend to and be tight against the exterior lwa/l. and wall assemblies shall extend from the foundation to the underside of the roof sheathing. Exceptions: 1_ A fire -resistance rating of 1f2 hour shall be permitted in buildings equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13. WINDOW @ THIS AREA NOT 2_ Wall assemblies need not extend through attic spaces where the ceiling is protected by not less than 5/8-inch (15.9 mm) Type X gypsum board, an attic draft stop constructed as specified in Section SHOWN R302.12.1 is provided above and along the wall assembly separating the dwellings and the structural framing supporting the ceiling is protected by not less than 1/2-inch (12 7 mm) gypsum board or equivalent PRE-FAB GAS FIREPLACE VENTED THRU REAR WALL R302.3.1 Supporting construction. Where floor assemblies are required to be fire -resistance rated by Section R302.3, the supporting construction of such assemblies shall have an equal or greater fire -resistance rating. PTD. MDF TRIM MOLDING AS SELECTED BY CLIENT ' I I I I I ` ' I I CLIENT BRACKET PIECE CLIENT SELECTED TILE VENEER CLIENT SELECTED VENTED GAS FIREPLACE FIREPLACE / BUILT-IN SHELVES ELEVATION PTD. MDF TRIM MOLDING AS SELECTED BY CLIENT cr PTD. MDF 1 x 4 TRIM 0a W J W W W i3 z z w Cn CI- 0 z o Cn O 0 U III a o O U Cc a z = c� J W o� z r; z W CI - Cc O PTD. MDF 1 x 4 TRIM LJ_ - 0 CLIENT SELECTED PTD. MDF BASEBOARD '_ CASED OPENING ELEVATION Fireplace Plan & Elevation / Cased Opening Trim 1 /211 = 1 '-011 HALLWAY LAUNDRY ROOM 2 x 6 LAUNDRY ROOM RAISE 2 x 6 WALL SILL PLATE DRYER VENT BOX AT LOCATION OF METAL METAL DRYER VENT w/ VENT BOX 90 DEGREE TURN (ALL OTHER SILL PLATES —L-i ADVANTECH FLOOR SHEATHING @ BOTTOM OF WALL _ _ I FINISH FLOOR LEVEL INSTALL CENTER OF HORIZONTAL METAL DUCT 4" ABOVE ADVANTECH FLOOR SHEATHING AS SHOWN Section th ru Dryer Vent Box THIS DETAIL IS APPLICABLE IF MAG-180 MAGNETIC DRYER VENT IS USED. BEFORE DRYER VENT INSTALLATION, VERIFY HEIGHT OF VENT (ABOVE FLOOR) w/ OWNERS DRYER Dryer Vent Box Section 4 1 1 /2" = 1 '-011 MIN. 23/32" WOOD STRUCTURAL PANEL SUBFLOOR, SEE STRUCTURAL DRAWINGS — FACE OF STUD @ WALL RESILIENT CHANNELS J — CABINETS AS SELECTED B 1 LAYER 5/8" 'X' GYP. BD. OWNER CLIENT SELECTED PTD. MDF BASEBOARD 1 HOUR RATED PER UL DESIGN No. L521 0 WOOD PARALLEL CHORD TRUSSES, MAX. 24" O.C., MIN. TRUSS DEPTH 12" SEE STRUCTURAL DRAWINGS BATT INSULATION (OPTIONAL) 1 HOUR RATED TRUSS FLOOR ASSEMBLY 1 1 /2" = V-0" DESIGN NO. UL U305 FIRE RATING: 1 HOUR STC RATING: 49 SOUND TEST: USG-161201 SYSTEM THICKNESS: 7-1/4" [184 MM] LOCATION: INTERIOR FRAMING TYPE: WOOD STUD (LOAD -BEARING) 16" 16" [406 mm] [406 mm] 7 E �00 ASSEMBLY REQUIREMENTS: 16" [406 mm] 16" [406 mm] GYPSUM PANELS: ONE LAYER 5/8" [15.9 MM] SHEETROCKO ECOSMART GYPSUM PANEL (UL TYPE ULIXTI,,) RESILIENT CHANNEL: 1/2" [12.7 MM] RESILIENT CHANNEL, 25 GA. (0.018"), 24" [610 MM] O.C. WOOD STUDS: 2" X 6" [38 X 140 MM] WOOD STUDS, 16" [406 MM] O.C. INSULATION: 6-1/4" [159 MM] FIBERGLASS INSULATION GYPSUM PANELS: ONE LAYER 5/8" [15.9 MM] SHEETROCKO ECOSMART GYPSUM PANEL (UL TYPE ULIXT"") Provide artificial light source per R303.6 Stair Guard Min. 34". Handrail height above stair 34" to 38" Max A 4" sphere cannot pass through the space between treads. - - 36" min. landing 36" min to top of guard Graspable Handrail 1 1i4" min. to 2" max.. Handrail ends shall be returned or shall terminate at a newel post or safety -- terminals. ttermediate rails paced so that a " sphere shall not ass through ,f 1 STAIR REQUIREMENTS 10" min. to 1-%" nose. �' or min. 11" tread Rise -run -rail opening / spaced so that a 6" sphere shall not pass through Guard and handrail to sustain 200 lb. load Guard balusters to sustain 50 psf load Install gypsum board on walls and ceilings of all useable interior space under stairs. RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL WALL NOTES: 1. REFER TO APPLICABLE CODES REQUIREMENTS TO ENSURE COMPLIANCE PRIOR TO CONSTRUCTION. 2. FOR THE MOST UP-TO-DATE DETAILS, INCLUDING CONSTRUCTION VARIATIONS, REFER TO THE PUBLISHED DESIGN. 3. WHERE DESIGN NO. INDICATES "PER", THE FIRE RATING IS BASED ON LABORATORY TEST DATA OF THE REFERENCED SIMILARLY CONSTRUCTED ASSEMBLIES. 4. STUD SIZES AND INSULATION THICKNESS ARE MINIMUM UNLESS OTHERWISE STATED IN THE PUBLISHED ASSEMBLY. 5. STUD AND FASTENER SPACINGS ARE MAXIMUM UNLESS OTHERWISE STATED IN THE PUBLISHED ASSEMBLY. 6. PANEL ORIENTATION SHALL BE AS SPECIFIED IN THE PUBLISHED DESIGN. 7. FIRE -RATINGS ARE FROM BOTH SIDES UNLESS OTHERWISE STATED. 8. FIRE -RATINGS ARE MAINTAINED WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS: INCREASE STUD DEPTH. INCREASE STUD MATERIAL THICKNESS. DECREASE STUD SPACING, DECREASE FASTENER SPACING. INCREASE INSULATION THICKNESS UP TO CAVITY DEPTH. 9. WHERE ACOUSTICAL PERFORMANCE IS PROVIDED IN AN ESTIMATED RANGE, THE VALUES ARE BASED ON LABORATORY TEST DATA OF SIMILARLY CONSTRUCTED ASSEMBLIES. 10. SOUND -RATINGS ARE MAINTAINED WITH ONE OR MORE OF THE FOLLOWING MODIFICATIONS: INCREASE STUD DEPTH, DECREASE STUD MATERIAL THICKNESS, INCREASE STUD SPACING, INCREASE FASTENER SPACING, INCREASE INSULATION THICKNESS UP TO CAVITY DEPTH. MODIFICATIONS MUST NOT EXCEED LIMITATIONS OF FIRE RATING. DISCIAMER THE USG PRODUCT INFORMATION CONTAINTED HEREIN ARE INTENDED FOR USE AS ISSUE SHEET INFORMATION: USG PRODUCT REFERENCE MATERIAL BY ARCHfTECTS, ENGINEERS. AND OTHER DESIGN PROFESSIONALS, CONTRACTORS. BUILDING CODE OFFICIALS. OR OTHER COMPETENT CONSTRUCTION INDUSTRY TRADE RECORD: USG Cof oration P PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION. AND USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE USG PRODUCTS AND NOT INTENDED TO BE ASUBSTITUTE FOR THE DESIGN REVIEW AND APPROVALOF THE LICENSED DESIGN U L U305 Revision Date W P 1 16 550 West Adams Street Chicago,IL 60661 USA PROFESSIONALS FOR THE PROJECT THESE MATERALS MAY BE PRINTED ANDIOR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER BECAUSE CAD ELECTRONIC FILES AND BIM (BUILDING INFORMATION MODELING( FILES CAN BE MODIFIED BY OTHER PARTIES. WITHOUT NOTICE OR www.USG.com T.800-USG4YOU INDCATION OF SUCH MODIFICATIONS, MODIFCATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN PROFESSIONAL 1O1051202111:55:06PM I Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Pro-ject Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Interior Details 7543 REGISTERS ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description 1 7-18-2023 PERMIT REVISION DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 02/16/23 A-41lii,3 Drawn By Author Interior Details Scale As indicated Sheet Plot Date 7/17/2023 1:56:42 PM www.CarIColsonArchitect.com WINDOW FLASHING DETAILS Step 1: Prepare the WRB at the rough opening: install a small section of house wrap below the sill (referred to as an , apron ); alternatively, install self-adhesive pan flashing with split backing (where the release paper backing can be removed incre- mentally) to seal to the house wrap later. Step 2: Install pan flashing: cover the rough sill and extend onto the face of the wall/ WRB. Step 3: Install the window: according to manufacturer instructions. Step 4: Install the jamb flashing: over window flange and pan flashing and extend above the head flange. Step 5: Install the head flashing: over and beyond the jamb flashing (and over the win- dow drip cap if installed). Step 6: Integrate the WRB: Install house wrap shingle -fashion, integrated with the apron, and seal house wrap at jambs and head using sealant (beneath the house wrap) or construction tape. HEAD FLAI llk AI/lTr-. Or-r- AI/lTr- nr-I /11A1 DRAWING HEAD FLA WEATHEI HYDROG (BENJAMI OBDYKEI PENETRA OBDYKEI HEAD FLj AT WIND( FLASHIN( FLASHIN( EXTER101 DETAIL BI Flashii over h 10' to slope Flashii tape over t windo flange Head Flashii over s windo 3 O O SILL FLASHING NOTE: il INSTALL BENJAMIN OBDYKE HYDROCORNER SILL FLASHING @ ALL WINDOW SILL CORNERS. Q INSTALL BENJAMIN OBDYKE HYDROFLASHO GP SILL / PENETRATION FLASHING OVER CORNER SHIELD, AS EXTRA PREVENTION FOR LEAKS @ SILL CORNERS 0 FRAMER NOTE: THESE ARE ROUGH OPENING DIMENSIONS (VERIFY w MILGARD PRIOR TO FRAMING ALL WINDOW OPENINGS) BUILDER NOTE: VERIFY EXTERIOR AND INTERIOR FINISHES w/ ALL EXTERIOR DOORS w/ OWNER PRIOR TO ORDERING EXTERIOR DOORS (TYP) WINDOW TYPE LEGEND SINGLE HUNG WINDOWS SEE PLANS & ELEVATIONS FOR DOUBLE HUNG WINDOW LOCATIONS COORDINATE W/ WINDOW MANUFACTURER FOR ACTUAL WINDOW FRAME SIZE & ROUGH OPENING DIMENSIONS (TYP @ ALL WINDOWS) ALL WINDOWS SHALL BE MILGARD ULTRA SERIES A B C D E F G H I J MILGARD ULTRA 3050 MILGARD ULTRA 3050 MILGARD ULTRA 2850 MILGARD ULTRA 3040 MILGARD ULTRA 2840 MILGARD ULTRA 2640 MILGARD ULTRA 2640 MILGARD ULTRA 3036 MILGARD ULTRA 2836 MILGARD ULTRA 2836 THESE DIMENSIONS SINGLE HUNG w RID SINGLE11 HUNG SINGLE HUNGw RID SINGLE HUNG SINGLE H SINGLE H11 UNG w GRIDS SINGLE HUNG SINGLE HUNG SINGLE HUNG w GRIDS SINGLEHUNG HUNG REPRESENT THE WINDOWS 3 3N 2 SUNG 311 3 0 2 S ROUGH OPENING 7� / / / / �, �� 7� Ir / / DIMENSIONS. VERIFY w/ MANUF. PRIOR TO FRAMING (TYP @ ALL WINDOWS) E E:1 JAMB EXTENSIONS co ME:1 CD co co co VERIFY 6-9/16" JAMB o o EXTENSIONS w/ MILGARD o E:1 PRIOR TO ORDERING WINDOWS (TYP) M SKYLIGHT WINDOW & DOOR TRIM NOTES EXTERIOR TRIM INTERIOR TRIM K L N DOOR & WINDOW EXTERIOR TRIM DOOR & WINDOW INTERIOR TRIM DOOR & WINDOW INTERIOR TRIM MILGARD ULTRA 2436 MILGARD ULTRA 2430 2030 ALL DOOR & WINDOW EXTERIOR TRIM SHALL BE PRIMED ALL DOOR & WINDOW INTERIOR TRIM 1) COORDINATE ALL INTERIOR DOOR & SINGLE HUNG SINGLE HUNG SKYLIGHT AND PAINTED CEDAR TRIM w/ SMOOTH FINISH SHALL BE PRIMED AND PAINTED MDF WINDOW FINISHES WITH OWNER. 2' - 4" 2' - 4" — PTD. SLOPED CEDAR TRIM & METAL - BLINDS / SHADES LOCATION 2) AT DOORS &WINDOWS WITH FLASHING @WINDOW TRIM HEAD �— SEE BLOCKING NOTE IN WINDOW INTERIOR FINISH THAT IS TO BE PAINTED, CD . LL�Jj I;tSIMPSON co SIDELITES M @ ENTRY DOOR 18" X 94" COORD. SKYLIGHT 3/ ROUGH OPENING DIM. w/ MAN UF. \X/ GENERAL NOTES THE TRIM SHALL BE PRIMED AND SEE BLOCKING NOTE IN WINDOW \ / PAINTED MDF GENERAL NOTES \ / SCHEDULED WINDOW OPENING 5/46 PTD. CEDAR TRIM @ HEAD \ / 1x4 PTD. MDF TRIM @ SIDE, HEAD, & \ / SCHEDULED WINDOW OPENING x SILL / \ PTD. MDF TRIM @ SIDE, HEAD, & SILL. 5/4 x 6 PTD. CEDAR TRIM @ SIDE JAMB / \ COORDINATE SELECTION w/ OWNER 2x PTD. CEDAR SILL W/ SLOPE 1-1/2" OVERHANG ON SILL / \ 5/4x4 PTD. CEDAR TRIM @ BELOW SILL Tang Residence Window Schedule QTY U-VALU TAG ID WIDTH HEIGHT AREA TYPE GLAZING E COMMENTS A 14 3' - 0" 5' - 0" 210 SF Single Hung Low E 0.28 With Grids - See Window Legend B 8 3' - 0" 5' - 0" 120 SF Single Hung Low E 0.28 No Grids C 2 2' - 8" 5' - 0" 27 SF Single Hung Low E 0.28 With Grids - See Window Legend D 9 3' - 0" 4' - 0" 108 SF Single Hung Low E 0.28 No Grids E 3 2' - 8" 4' - 0" 32 SF Single Hung Low E 0.28 No Grids F 2 2' - 6" 4' - 0" 20 SF Single Hung Low E 0.28 With Grids - See Window Legend G 3 2' - 6" 4' - 0" 30 SF Single Hung Low E 0.28 No Grids H 5 3' - 0" 3' - 6" 53 SF Single Hung Low E 0.28 No Grids 1 4 2' - 8" 3' - 6" 37 SF Single Hung Single Hung Low E 0.28 With Grids - See Window Legend No Grids J 1 2' - 8" 3' - 6" 9 SF Low E 0.28 K 3 2' - 4" 3' - 6" 25 SF Single Hung Low E 0.28 No Grids L 2 2' - 4" 3' - 0" 14 SF Single Hung Low E 0.28 No Grids M 2 1'- 6" T - 10" 24 SF Sidelights by Simpson Low E 0.28 By Simpson to match Entry door N 6 2' - 0" 3' - 0" 36 SF Skylight Grand total 744 SF WINDOW GENERAL NOTES 1. CONTRACTOR SHALL VERIFY ALL WINDOW QUANTITIES AND SIZES BEFORE EGRESS WINDOWS ORDERING ALL SLEEPING ROOMS ARE REQUIRED TO HAVE EGRESS WINDOWS. THE 2. ALL WINDOWS SHALL HAVE DOUBLE GLAZING (1/2" MIN. AIR SPACE) WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 3. ALL OPERABLE WINDOWS SHALL HAVE INSECT SCREENS. SQUARE FEET. THE MIN. NET CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24" AND THE MIN. NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE WINDOW SERIES 20". ALL EXIT WINDOWS SHALL HAVE SILLS NO HIGHER THAN 44" ABOVE THE ALL WINDOWS SHALL BE MILGARD ULTRA SERIES WINDOWS WITH LOW-E FINISH FLOOR. /CLEAR GLASS (W/ ARGON) WITH A MIN. U VALUE OF 0.28. INTERIOR SHALL BE WINDOW SUPPLIER SHALL VERIFY ALL EGRESS WINDOWS MEET EGRESS WHITE AND EXTERIOR SHALL BE BLACK (TYP). REQUIREMENTS BEFORE ACCEPTING ORDER FROM CONTRACTOR. SAFETY GLAZING BLOCKING AT WINDOWS ALL GLASS LOCATED IN AN AREA WHICH THE 2018 INTERNATIONAL PROVIDE BLOCKING @ EACH END OF WINDOW HEADERS FOR 1 STUD SPACE RESIDENTIAL CODE CONSIDERS HAZARDOUS SHALL BE SAFETY GLAZING. TO ACT AS BACKING FOR INSTALLATION OF VALANCES / CURTAIN ROD THESE INCLUDE: ASSEMBLIES A.) ALL GLAZING IN DOORS AND GLAZING IN ANY OPENING ADJACENT TO A DOOR WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A WINDOW & EXTERIOR DOOR FLASHING INSTALLATION CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE CONTRACTOR SHALL INSTALL ALL WINDOWS AND DOORS PER GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. MANUFACTURERS INSTALLATION INSTRUCTIONS. B.) TUB / SHOWER ENCLOSURES. CONTRACTOR SHALL THEN INSTALL WINDOW WRAP FLASHING PER WINDOW WRAP DETAIL ON THIS SHEET. FENESTRATION CERTIFICATION ALL WINDOWS SHALL HAVE METAL DRIP FLASHING INSTALLED AT HEAD OF ALL NEW FENESTRATIONS SHALL BE NFRC CERTIFIED. WINDOWS. DOOR TYPE LEGEND INTERIOR DOORS ARE TO BE SIMPSON REDI-PRIME. DOOR HARDWARE 1 EXTERIOR WOOD DOORS TO BE SIMPSON. FIBERGLASS DOOR TO BE CODEL. ALL DOORS TO HAVE EXTERIOR TO ENTRY 2 3 4 5 6 LEVER STYLE HARDWARE PTD. SOLID WOOD W/ FINISH AS SELECTED SIMPSON GARAGE TO EXTERIOR OFFICE DOORS HOUSE TO GARAGE INTERIOR GARAGE DOOR @ ACCESSORY DWELLING UNIT (ADU) BY OWNER. ALL DOOR PTD. SMOOTH FIBERGLASS PTD. SOLID WOOD PTD. SOLID WOOD PTD. SOLID WOOD (SELECTION BY OWNER) HINGES & LOCKS TO ❑ (CODEL DOORS) MATCH LEVER FINISH DOOR, BASE, & TRIM ❑ ❑❑ PAINTING ❑ ❑ FROSTED ALL DOORS, BASE, DOOR & ❑ ❑' GLASS. WINDOW TRIM TO BE VERIFY w/ PRIMED & PAINTED W/ OWNER ENAMEL PAINT - COLOR SELECTION BY OWNER THESE DOORS @ HOME SEE WINDOW OFFICE SCHEDULE FOR � SIDELITES @ ENTRY ` DOOR SIDES F71 RESUB El Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT \ FLAT PANEL \ DOOR w/ SMOOTH FINISH Ll Ll PTD. SOLID CORE WOOD OR FIBERGLASS DOOR (SELECTION PTD. WOOD FRENCH DOORS PTD. SOLID CORE WOOD 1-3/4" THICK PTD. SOLID 16' x T OVERHEAD CARRIAGE -STYLE INSULATED METAL GARAGE DOOR W/ BY OWNER) W/ SECURITY LOCK & WEATHERSTRIPPING. SEE (W/ SAFETY GLASS ) DOOR (1-3/8" THICK) W/ CORE WD. OR MOLDED AUTOMATIC CLOSER & EXTERIOR KEY PAD.. CHAMBERLAIN B730/WD962 GARAGE PLAN & SCHEDULE FOR SIZE & SWING SEE PLAN & SCHEDULE FOR CLOSER, SECURITY LOCK & DOOR W/ PRIVACY DOOR OPENER ULTRA -QUIET BELT DRIVE, 3/4 HPS WITH BATTERY BACKUP SAFETY GLASS AT DOOR SIDELITES SIZE & SWING WEATHERSTRIPPING. SEE LOCK @ BEDROOM. SEE 9 PLAN & SCHEDULE FOR PLAN & SCHEDULE FOR GARAGE DOOR @ SINGLE FAMILY RESIDENCE 7 8 SIZE & SWING SIZE & SWING (SELECTION BY OWNER) KITCHEN TO PATIO KITCHEN TO PORCH 2 PANEL SLIDING 2 PANEL SLIDING GLASS DOOR GLASS DOOR T WIDE x 8' HIGH — 5' WIDE x 8' HIGH — w/ SAFETY GLASS w/ SAFETY GLASS BOTH DOORS SHALL BE FROM SAME MANUFACTURER 16' x 8' OVERHEAD CARRIAGE -STYLE INSULATED METAL GARAGE DOOR W/ AUTOMATIC CLOSER & EXTERIOR KEY PAD. AND CHAMBERLAIN B730/WD962 GARAGE DOOR OPENER ULTRA -QUIET BELT DRIVE, 3/4 HPS WITH BATTERY BACKUP Carl J. Colson -Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarlColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Project Client & Project Applicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Sheet Title Window Legend & Notes 77543 REGISTERS 7 1ARCHITECT CARL J. COLSON S ATE OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be tramsmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. O Project Number Sheet Issue Date 07/27/18 A-5,0 I Drawn By Author Window Legend & Notes Scale As indicated Sheet Plot Date 7/17/2023 1:57:04 PM www.CarIColsonArchitect.com 3 4 5 6 a 10 11 12 13 15 16 17 19 20 22 23 24 25 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 50 51 52 53 54 J.7 56 57 58 59 60 62 TANG RESIDENCE HEATING SYSTEM SIZE Project Information Contact information Tang Residence (New Home) Peter Tang (Owner) 340 Daley St. 644 Bell St, Edmonds, WA 98020 Edmonds, WA 98020 (425) 372-2584 / peterntang@gmail.com Heating System Type: 0 All Other Systems 0 Heat Pump To see detailed instructions for each section. place your cursor on the Nord "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Ll Edmonds -IJ 1T = Indoor i70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instruction`, Conditioned Floor Area (sq ft) 1 4 004 Average Ceiling Height Conditioned Volume IZIErucuo11 Average Ceiling Height (ft) 1 8.5 1 34.034 Glazing and Doors U-Factor X Area = UA Instruction u-0.28 0.280 846 23694 Skylights U-Factor X Area = UA Instruction) it ,i) 12 r, 00 Insulation Attic U-Factor X Area = UA Instructions �t -� 6396 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA ' i161i clad R-Value I J No selection --- Above Grade Walls (see Figure 1) U-Factor X Area UA InstrucT R-21 Intermediate I o.r_I�-c, 3 876 21706 Floors U-Factor X Area UA nstrucuoni 0 02 f- 1 �8.88 R-38 �.�.= N Below Grade Walls (see Figure 1) U-Factor X Area UA lisifuctions I rlr�:t R-:aluz � I No selection 0 - Slab Below Grade (see Figure p F-Factor X Length UA Instruction) I.1 17100 No Slab Below Grade in this project. Slab on Grade (see Figure 1) F-Factor X Length UA Instructions No selection 0 Select R-Value Se Location of Ducts Instruction) Duct Leakage Coefficient Conditioned Space Sum of UA 562.83 Envelope Heat Load 25.890 Btu ? Hour Sum of UA x _�T Air Leakage Heat Load 16.908 Btu ! Hour Volume x. 0.6 x _�T x. 0.018 Building Design Heat Load 42.798 Btu / Hour Arr leakage + et -,,.elope heat loss Building and Duct Heat Load 42.798 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 64] Ducts in conditioned space: sum of building heat loss x 1 65 Maximum Heat Equipment Output 53,498 Btu / Hour 66 Buildir;cl and duct heat loss x 1.40 for forced air furnace 67 Buildina and duct heat loss x 1.25 for heat pump Figure 1. TANG RESIDENCE GLAZING SCHEDULE 1 Window, Skylight and Door Schedule 2 Froiect Information, 3 Tang Residence (r,lew Home) 4 840 Daley St 5 Edmonds. WA 98020 6- 7 8 Ref U-factor g Exempt Swinging Door (24 sq ft max.) 10 Exempt Glazed Fenestration (15 sq ft max I Contact Information, Peter Tan (Owner) 644 Bell St Edmonds- WA 98020 425 372-2584..,'pi--teriitang@gniaiI com Width Heigylit (fit Feet _ Feet r.rea UA 1 3 8 1 � 5 � WSEC 0 48 i'ulanuf 0 28 tl tc 13 Vertical Fenestration (Windows and doors) 14 Component 15 Description IR Ref I U-facto 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Window Type A (Single Hun hlanuf 0 28 Window Type B (Single Hun 110anuf 0 28 Window Type C (Single Hun) ivlanuf 028 Window T e D (Single Hun) N-lanuf 0 28 Window Type E (Single Hun) 1','lanuf 0 28 Window Type F (Single Hung!' I'd anuf 10 20 Window Type G (Single Hun) 10anuf 0 28 Window Type H (Single Hun I-Januf 0 28 Window Type I (Single Hun hlanuf 0 28Window Type J (Single Hun P,'lanuf 0 28 Window Type K (Single Hun) hlanuf 0 28 Window Type L (Single Hun) hlanuf 0 28 Window Type M (Entry Door Sidelite; IvIanuf 0 28 3-Panel Sliding Door @ Kitchen hlanuf 2-Panel Sliding Door @ Kitchen Nlanuf Door From House to Garage WSEC 0 46 Door From ADU to Garage WSEC 0.46 Door From ADU to Exterior WSE 0 46 24 0 11 52 1 `=� 11 4 2 0 2018 WA ENERGY CODE, RESIDENTIAL PROVISIONS ENERGY CREDITS 2018 Washinqton _State Enerqy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Sinele Familv - New & Additions (effective February 1. 2021) Version 1-1 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information 'v',lidth Heigylit Tang Residence cat N Feet' Feet Ir'' Area UA 8-40 E)alev St. Edmonds, WA 13 3 5 8 3 5 0 2 2 - 9 3 4 2 2 - -1 - 2 2 4 2 4 = 3 a - 4 12 - 3 1 2 - 3 3 2 4 3 2 2 a 3 J 2 1 = 7 to 1 "o e '0 1 8 1 =; - 6 - 1 3 6 - 1 :_1 6 - 58 ; 59 Sum of Vertical Fenestration Area and UA 60 Vertical Fenestration Area Weighted U = UA/Area 61 1 62 Overhead Glazing (Skylights) 63 Component 64 Description Ref U-facto� 65 L'1,indo i Type N 'SkN,,li ht} Nlanuf 0 50 66 67 68 69 70 71 Width Height cat FeetFeet = 72 Sum of Overhead Glazing Area and UA 73 Overhead Glazing Area Weighted U = UA/Area 74 75 Total Sum of Fenestration Area and UA (for heating system sizing calculations) INSULATION, EFFICIENCY, LEAKAGE, & VENTILATION RATES CERTIFICATE (TO BE FILLED OUT BY CONTRACTOR) Property address: Builderlregistered design proteesional nanw BuilderNeg. design pro signature: Conditioned floor area: fe (per buif6ng permit) R-Values R303,1,1 Call.ng: Va�.ltr.d R- Floors Over unconditioned space R- Attic Attic R- slab -on -grade floor R- V alls Above pride R Fully insulated stab? YIN ICircr earl Mow Int R Doors: R. R._. R- liolow cat R- U-Value of Windows, Skylights and Doors (R303.1-1.3) Average area weighted U-value from Giazirgl Worl -0,eet Average U- Fuel Normalization Tablas R406.2 and Enargy Credits Taste R406 3) System Type Number I 1 to 51 i;�iRlart pr.e) Energy Credits selected (1 to 71 Fuel Normalization Credit + Total Energy Credits = Total Credits Heating, Cooling and Domestic Hot Water System T Manufacturer and Model Number Ef/icienc Hesling Coofing OMW Drain waler heal recovery Onsite Renewable Energy Electric Power System System type Systcrr design capacity _ kw Rated annual generatlon k'A'hryv Appliances Energy Star? Manufacturer and Modai j 1..rTia oral Dish washer Y or N Refrigerator Y or N Washer Y or N Dryer Y or N Vented or unvented? tf veMed. CEF raU Gas fireplace r heating stove (Section R402-4.21 Fireplace efficiency (FE) _ Hoofing or Decorative? IClrdle onel HVAC System Duct Leakage Testing (R403-3) c.rr-W one All ductwork and air handler in conditioned space? )See Option 4.2) Y or N All ductwork in unconditioned spaces buried and tested at 3% total leakage, and air Y or N handler in corxkboned space? (See Opbon 4. 1.) All ductwork 3 air handier outside conditioned space insulated to minimum R-117 Y a N Air handier presets at duct leakage test? (Toler leakage 4% if yes. 3% It no) Y or N HVAC leeksp to outside test conducted at final? Y or N Do HVAC duct leakage tests include GPS and time stamp vertficallon? Y or N HVAC system soakage test eaieulated design target- CFM C 2S Pa HVAC system soakage lest measured results: CFM a 25 Ps Building Leakage Testing (R402.4.1.2i Dwelling unit leakage feet calculated design target. _ ACH a 50 Pa Dwelling unit leakage test, measured results: ACH a 50 Pa Whole Building Leakage test (1112 corridor only) design target: CF*sf @ 50 Pa W'fwM Building Leakage test (112 corridor only) measured CFIWsf a 50 Pa Do building leakage tests include GPS and firviestarnp verification? Yoe N Wlioir House Venrifation System Weasured Flow Rates (M1505 4 iRC-WA) C.rrAv one Are the system controls correctly labeled? Y nr N The Whole House Ventilation (WHVI system operation and maintenance IOBM) Y or N instructions were provided to the buiking owner? Provided to: art (datel Whole House Ventilation System Type: (C rcle one) 11) Whole house exhaust fan, location 121 Balanced HRVI ERV. locabori For R2 low-rise, safvss more than one unit? Y or N 13) Supply or HRV WHV integral to the a►r handler. Describe system control sequence of operations or reference to design submittal: Specify run4lme: hours per day CFM WHV calculated design minimum flow rat* per plan submittal WHV measured min flow rate at commissioning Exhaust CFM. Supply CFM Do WHV flow tests inrflude GPS & time stamp verification? Y or N HRV)ERV sensible heat recovery effiuency: Commissioning Notes Other Manda" Repairements CirJr un.. FAIIther mandatory requirements of WSEC-R have been met? Y or N INSULATION CERTIFICATE (TO BE FILLED OUT BY CONTRACTOR) QEnergy Program Insulation Certificate for Residential New Construction Permit W House address or lot number. Walls Blown or Sprayed Fiberglass or Cellulose - Walls Type of insulation: R-value per inch: Manufacturer coverage area: 11-value: Bag count: Flow Blown or Sprayed Fiberglass or Cellulose - Ceiling Type of insulation: R-value per inch: Manufacturer_ Coverage area. R-value: Bag count: Flat ceiling/Attic Sprayed Polyurethane Foam (SPF) Type of insulation: Density: Manufacturer installed thickness: R-value R-value of installed thickness: Single Rafter Joist Vaulted Ceiling Building component installed: (circle one) walls floor ceiling Type of insulation: Manufacturer: 11-value: Insulation Installer Company name Installer name: Installer signature: Date: Phone number: Email: Washinnon State Energy Code Reference R303.1 Identification. Materials, systems and equipment shall be identified in a manner Owl. viiA aliuvo I determination of compliance with the applicable provisions of this code. R303.1.1 Building thermal envekipe insulation- An R-value identification mark shall be applied by the manufacturer to each piece of building thermal envelope insulation 12 inches (305 mm) or greater in width. Alternately, the insulation installers shall provide a certification listing the type, manufacturer and R-value of insulation installed in each element of the building thermal envelope. For blown or sprayed insulation (fiberglass and cellulose), the Initial installed thickness, settled thickness, settled 11-value, installed density, coverage area and number of bags installed shall be listed on the certification. For sprayed polyurethane foam (SPF) Insulation, the installed thickness of the areas covered and R-value of installed thickness shall be listed on the certification. For insulated siding, the R-value shall be labeled on the product's packMe and shall be listed on the certikation. The insulation installer shall sign, date and post the certification in a conspicuous location on the job site. Exception: For roof insulation installed above the deck, the 11-value shall be labeled as required by the material standards specified in Table 15M.2 of the International Building Code or Table R906.2 of the international Residential Code. 195 01 54 60 120 0 33 60 26 7 747 108 G 30 24 21 3 5 97 2G 0 = 60 30 G 3 40 52 5 14 70 37 3 10 45 9-3 2 61 24-5 6 86 140 392 23 5 6.58 00 000 64G 000 40 G 0 00 00 000 20 G 9 20 20 01 9 20 20 01 9 20 84G 2 218 61 0 26 Area Ur". 12 01 600 00 000 00 000 00 000 00 000 GG G0G 120 600 0 50 897 21 240 33 Contact Information Peter Tang (Owner) (425)- 372-2584 i Deterntanatd)amail.com Summary of Table R406.2 and 406.3 Heating Fuel Normalization Descriptions Credits -select ONE Options heating option User Notes 1 Combustion heating minimum NAECAb 0.0 0 2 Heat pumps 1.0 3 Electric resistance heat only - furnace or zonal -1.0 0 4 DHP with zonal electric resistance per option 3.4 0.5 0 -1.0 0 Credits - select ONE energy option from each category V 5 Energy Options All other heating systems Energy Credit Option Descriptions Efficient Building Envelope Efficient Building Envelope Efficient Building Envelope Efficient Building Envelope 1.1 0.5 0 1.2 1.0 0 1.3 0.5 1.4 1.0 Q 1.5 Efficient Building Envelope 2.0 Q 1.6 Efficient Building Envelope 3.0 0 1.7 Efficient Building Envelope 0 0.5 Q 2.1 Air Leakage Control and Efficient Ventilation 0.5 2.2 Air Leakage Control and Efficient Ventilation Air Leakage Control and Efficient Ventilation 1.0 O 0 2.3 1.5 2.4 Air Leakage Control and Efficient Ventilation 0 2.0 0 3. la High Efficiency HVAC 1.0 0 3.2 High Efficiency HVAC 1.0 0 3.31 High Efficiency HVAC 1.5 0 3.4 High Efficiency HVAC 1.5 0 3.5 1 High Efficiency HVAC 1.5 3.61 High Efficiency HVAC 0 High Efficiency HVAC Distribution System 2.0 0 4.1 0.5 Q 4.2 High Efficiency HVAC Distribution System 0 1.0 Q 2018 Washinqton State Enerqy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1. 2021) Energy Options 5.1d 5.2 5.3 Energy Credit Option Efficient Water Heating Efficient Water Heating Efficient Water Heating Summary of Table Descriptions (cont.) R406.2 (cont.) Credits - select ONE energy option from each category =' 0.5 ❑ 0.5 0 1.0 0 5.4 Efficient Water Heating 1.5 0 5.5 Efficient Water Heating 2.0 0 5.6 Efficient Water Heating 0 2.5 0 6. le Renewable Electric Energy (3 credits max) 1.0 7.1 Appliance Package 0.5 ❑ Total Credits 6.0 ENERGY CODE CERTIFICATE COMPLIANCE CERTIFICATE: PART OF THE WSEC. ALL NEW RESIDENCES ARE REQUIRED TO POST THIS CERTIFICATE WITHIN 3 FEET OF THE ELECTRICAL SUPPLY PANEL. CERTIFICATE MUST BE COMPLETELY FILLED OUT AND POSTED AT TIME OF FINAL INSPECTION. THIS REQUIREMENT IS THE RESPONSIBILITY OF THE BUILDER. MECHANICAL SUBCONTRACTOR NOTE: THE CALCULATIONS FOR HEATING SYSTEM SIZE ARE REQUIRED BY THE WASHINGTON 2018 ENERGY CODE AND WAS COMPLETED AS PART OF THE BUILDING PERMIT SUBMITTAL. THE MECHANICAL SUBCONTRACTOR FOR THIS RESIDENCE SHALL SIZE ALL HEATING EQUIPMENT PER WSEC AND SHALL COORDINATE SIZING AND SELECTION OF EQUIPMENT WITH DEVELOPER / BUILDER PRIOR TO PURCHASING OR INSTALLING THIS EQUIPMENT User Notes Calculate Totall I Clear Form RESUB Jul 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Carl J. Colson - Architect PLLC 2502 Washington Blvd, Anacortes, WA 98221 425-773-4392 wwwCarIColsonArchitect. com Commercial & Residential Architecture Tang Residence Project Address 840 Daley St. Edmonds, WA Proiect Client & Proiect Annlicant Peter & Jia Tang 648 Bell St. Edmonds, WA 98020 206-372-2584 Washington State Energy Code Calculations 7543 REGISTERS ARCHITECT CARL J. COLSON S AT OF WASHINGTO Issued For Permit: 04-05 - 2023 Document Set Type: Revision Schedule Rev. # Date Description DRAWING USE NOTIFICATION This set of drawings is being issued as a Progress or Permit Set of Drawings and is subject to change and adding of additional information and drawings as required by review of the Building Department in the jurisdiction where this project is located. DO NOT USE THIS DRAWING FOR CONSTRUCTION UNLESS THIS DRAWING HAS A BUILDING DEPARTMENT "APPROVED" STAMP APPLIED BY THE BUILDING DEPARTMENT UPON COMPLETION OF THE PERMIT REVIEW PROCESS. Do not use this drawing for Bidding or Estimating Purposes unless authorized by Client. During Construction Phase, the Clients General Contractor (Builder) or Developer shall be responsible for ensuring that all Construction Personnel of the General Contractor and all Subcontractors are supplied with all Approved and most current documents. ARCHITECTURAL COPYRIGHT This sheet of drawings may not be reproduced in any form without prior approval of Carl J. Colson - Architect PLLC. These document, the ideas, and designs incorporated herein as an instrument of service shall remain the property of Carl J. Colson - Architect PLLC and are solely for the use on this project only. These files, drawings, ideas, or designs may not be transmitted electronically without express permission of Architect. They are not be used by the client or any other party or entity on other projects, in whole or part, or as an extension to this project except by agreement in writing with appropriate financial compensation to Carl J. Colson - Architect PLLC. Copyright Carl J. Colson - PLLC, 2023. All rights reserved. Project Number Sheet Issue Date 04/29/13 A-6,s Drawn By Author Washington State Energy Code Scale Calculations 12" = 1'-0" Sheet Plot Date 7/17/2023 1:57:29 PM www.CarlColsonArchitect.com