ENG CORRECTION NOTICE 6.10.2024 (2)CITY OF EDMONDS
of E114o CORRECTION NOTICE
1P ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.gov
Fst. 1 890
DATE: 6/10/2024 PERMIT NUMBER: BLD2023-0433
OWNER: Peter
ADDRESS: 840 Dalev St
TYPE OF INSPECTION: FINAL INSPECTION
SITE CONTACT: Shane Fortney
WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED
APPROVED PLANS AND PERMIT JOB CARD MUST BE AVAILABLE TO
INSPECTOR ON SITE
® CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED AND/OR THE NEXT PHASE OF WORK IS STARTED.
® RECALL FOR INSPECTION
❑ REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST.
❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR
1. Prior to receiving final construction approval from the Engineering Division, The straw shall be
removed from both the west and east sides of the house and the soils shall be compost amended
per city standard detail SD-642. Please make sure to include the area on the east property line
near the utility pole.
2. The frame on the manhole in the front yard shall be mudded down.
3. The frame on the catch basin in the front yard shall be mudded down.
4. The edge of the driveway that borders the alley shall be backed up with crushed rock.
5. Since the wrong cast iron lamphole cover was installed on the 6" sewer lateral at the alley please
either swap it out with the cast iron lamphole cover in the front yard or drill a 3/4" pick hole in
the lid.
6. Pour a 2' x 2' concrete leveling collar around the 12" cast iron lamphole cover at the alley.
THE ACTIONS OR CORRECTIONSINDICATED ABOVE ARE REQUIRED TO BE
CORRECTED BY: prior to final OR PENALTIES MAY BE APPLIED. FOR INSPECTION
z SCHEDULE THROUGH mybuildingpermit.com
Inspector: Jeff Whatmore
Date: 6/10/2024