Loading...
ENG PROJECT ASBUILT - LF0 m` rp) 3 �a 0 I o EN Q- N N I � oN N O 0 I >< N � Z NE1/4, SW1/4, SEC 24, TWP 27N, RGE 3E, W.M. N I I o` I ; �� JVLfU /CV(JfyUlot l o III I LOCKING LID III li i I HOUSE N-10552.31 111 MAIN FF 175.56 E 11000.62 I i 1 I U III ! I Rl 175.40 i I II N 4 �L� BSBL 4" E 171.90 (IN -NE) Il i I ,III (TYP) 8" �E - III I O 6" IE X69.20 (OU N) I lr - III o I i �; ml I--------�, ;;III I m 1 CITY OF EDMONDS BLK 81 VOL. 2 PG, 39 "' lii 1 1 i, V, l DOWNSPOUT / SSCO Iilll 1IF , RIM 175.0 i111I I 1 I w - - - II - - f - lE 172.5 I I I I N I I. f. i. r I I l I II I 1 fly of 1 I fl P]7x0 ...•).1 ill I 1 1. d �. :. I I 1 7 III II / I 1 4" PVC SEWER GARAGE i 111 I HOUSE SER VICE ® ----FF 175.18 -- I l J `�\ i 2.07. MIN I ill h cn I SDCO 4 I iII I 175.18 FG I ci ,N N 4" PVC I ` S ii DOWNSPOUT !DOWNSPOUT I iII o l 0 RIM 175.00 1 I I 2 1 I v 4" /E 172.40 1 I i ip ® l I 175.18 FG lily 1 D , �. C i CHANNEL DRAIN ,, . L , TOP 175.00 ----T---�---- T:.-:.; NOS PRO CHANNEL DRAIN 15 �SBL SDCO 5 :.. CONCRETE; �? ; ' OR APPROVED EQUAL c5 i 4" PVC " 'Df?l U£k17A Y (SEE DETAIL ON SHT D T- 02) RIM 175.00 /L O UU1vf.. 1V - /OL. /L xi I RE -USED. CONTACT ENG/NEER/NGPERMITSCDMONDSWA.GOV .O SCHEDULE: :.:: :.:.... lE 8"GONG E=162.82 „.. " INSPECTION. IF THE LINE IS DAMAGED OR NOT A 6.. LINE FROM. THE MAIN. /!�E........ r............... lE 8 CONC(W)-162 72 TO THE PROPERTY LINE THE SEWER �A�ERAL SHALL -BE REPLACED " EX 8 CONC SEWER SS S-S . :SS: T: TT.: S CITY OF EDMbNDS BLK 81 LOT 31 LOT 30 I LOT 29 VOL, 2y I PG. 39 LOT 28 I LOT 27 BUILDING HEIGHT CALCULATIONS (AEG) ELEVA 77ON A: 174.58 ELEVA 77ON B. 176.38 ELEVA 77ON C. 176. 53 ELEVA 77ON D: 175.48 TOTAL: = 702.97 AVERAGE ORIGINAL GRADE (AOG) = 175,74 MAIN FINISHED FLOOR = 175.56 ROOF A T RIDGE = 200.21 ALLOWABLE BUILDING HEIGHT = 200.74 (175.74 + 25 FT) IMPERVIOUS AREAS HOUSE+COVERED D/W, PATIO, PORCH, WALK 3,160 SF UNCOVERED PA770 AND WALK 271 SF UNCOVERED DRIVEWAY 813 SF TOTAL = 4,244 SF LOT COVERAGE LOT AREA: 8,201 SF ALLOWABLE COVERAGE (359) 2,870 SF HOUSE, COVERED DECK & GARAGE 2,868 SF PERCENT COVERAGE 34.979 SOILS NOTE ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T.5.13. PROJECT CLASSIFICATION PROJECT CLASS/FICA 770N: CA 7EGORY 1 EDMONDS WA 7ERSHED BASIN: SHELL CREEK FLOW CONTROL STANDARD: EXEMPT, LESS THAN 10,000 SF STORMWA TER BMPS, DETENTION PIPE POST CONSTRUCTION SOIL AMENDMENT (T5.13) N Stake trees in tree pits or trees under 2" cal.: Provide (4) 2x2 or 2x4 pt. wood or metal fence posts, secure tree with poly. webbing straps at 1131 of tree. Provide 2-4" approved mulch throughout plant beds. do not place against trunk as shown Edge beds with continuous trench at lawns and hardscape, 4" min depth as shown to hold mulch Compacted or undisturbed so11 Fill and compact base -- of pit to set root polar SCALE: 1" = 10' 0 5 10 20 ML4 NOTES: 1. Set tree plumb and vertical. 2. Rotate tree to align as grown in field: north face to North. 3. Prune dead, damaged and crossing branches. Elevate branches as per City standards where applicable. Do not cut branch lips or central leader. 4. Remove all stakes and guys after 12 months. Guy all trees over 2" cal. in plant beds: Secure 2x2 pit. wooden stakes - min (3) per tree, equally spaced. with poly. webbing straps at first branch or at 113 height of bee, whichever is higher. It wire guy and hose is used, Include fluorescent color tags on ea. wire at mid point. Mound soil around outside of root ball approx. 3" 11 or on downhill side of sloped beds: remove after growing season _ Remove strapping, wire basket and burlap from top 1/3 minimum of root _ ball. Cut any girdling Backfill pit w/ approved 1-4" above finish grade. II I ' clean Planting mix in 12" III -I - -� -� max. lifts, lightly compact to hold root ball 2 x roct ball dia !/71f1 TREE PLANTING DETAIL NOT TO SCALE ------------ - N -- - PU GIFTMUND - - - - - CASPERS - - - - - N - - - - - y - - - - - - - - - - EDMONDS - - -4i - `rT TREE SCHEDULE SYMBOL BOTANICAL NAME/COMMON NAME QTY. SIZE ACER CIRCINA TUM / VINE MAPLE 3 MIN. 1-1/2" CALIPER TREE NOTES 1. THERE ARE NO SIGNIFICANT TREES (6" DBH) AS DEFINED BY ECDC 23.10.020.R. 2. 3 SIGNIFICANT TREES TO BE PLANTED PER PLANTING REQUIREMENTS ECDC 23" 10.060. C. 5. J. ORANGE PROTECTIVE BARRIER FENCING SHALL BE PLACED AT THE DRIP LINE OF TREES TO REMAIN AND AROUND AREAS PROPOSED FOR LOW IMPACT DEVELOPMENT TECHNIQUES, SUCH AS RAIN GARDENS, INFIL IRA LION SYSTEMS, ETC., TO PROTECT THE AREA FROM COMPACTION. UTILITY SEPARATION REQUIREMENTS WA TER • 18" MIN/MUM COVER FOR WATER SERVICES. • 3' MIN/MUM HORIZONTAL SEPARATION BETWEEN WATER SERVICES AND ALL OTHER U77LI71ES, EXCEPT SANITARY SEWER. • 10' HORIZONTAL SEPARATION BETWEEN SANITARY SEWER AND W47ER MAINS OR SERVICES. • 12" MIN/MUM VERTICAL SEPARATION, FOR PERPENDICULAR CROSSINGS, BETWEEN WATER MAINS OR SERVICES AND ALL OTHER U7IL/T/ES, EXCEPT SANITARY SEWER. SANITARY SEWER 2 MINIMUM COVER FOR SIDE SEWERS &LATERALS. • 5' MINIMUM HORIZONTAL SEPARATION BETWEEN SANITARY SEWER AND ALL OTHER U77L/TIES EXCEPT WA 7ER. • 10' HORIZONTAL SEPARATION BETWEEN SANITARY SEWER AND WA TER MAINS OR SERVICES. • 12" MIN/MUM VERTICAL SEPARATION, FOR PERPENDICULAR CROSSINGS, BETWEEN SANITARY SEWER AND ALL OTHER U77L177ES, EXCEPT WATER. • 18" MIN/MUM VER 77CAL SEPARATION BETWEEN WATER AND SEWER, SEWER LAID BELOW WA TER. STORM • 1' MINIMUM COVER REQUIRED /N LANDSCAPE AREAS; 2' MIN/MUM COVER REQUIRED UNDER DRIVABLE SURFACES, UNLESS DUCTILE IRON PIPE IS USED. • 5' MIN/MUM HORIZONTAL SEPARATION BETWEEN STORM AND ALL 07HER UTILITIES. OUTSIDE AGENCY U7LI ZZES • 36" MIN/MUM COVER FOR JOINT GAS, ELECTRIC, TELEPHONE, CABLE TV SERVICE AND CONDUCTORS. • 36" MIN/MUM COVER FOR A PRIMARY DISTRIBUTION SYSTEM. ELECTRIC VEHICLE CHARGING STATION NOTE 7HE VEHICLE PARKING SPACE WI THIN THE GARAGE SHALL BE ELEC7R/C VEHICLE READY. THE GARAGE SHALL INCLUDE A FULL Y- WIRED CIRCUIT WITH LEVEL lI OR LEVEL III (PER ECDC 1 Z 115) ELECTRICAL VEHICLE CHARGING RECEPTACLE OUTLET OR TERM/NATION POINT, INCLUDING CONDUIT AND WRING AND 771E ELECTRICAL SERVICE CAPAC/TY (208 V/40 AMP MIN/MUM) NECESSARY TO SERVE THE RECEPTABLE, 7HAT ALLOWS FOR FUTURE INSTALLATION OF AN ELEC7R/CAL VEHICLE CHARGING STATION. UTILITY NOTE ALL NEW U77L/T/ES ARE REQUIRED TO BE INSTALLED UNDERGROUND. IF THE RIM TO INVERT OF ANY CATCH BASIN EXCEEDS 5 FEET A TYPE ll CATCH BASIN WILL BE REQUIRED. FOOTING DRAINS TO CONNECT TO DETENTION PIPE. STORMWATER CONTROL SUMMARY PROJECT S17E CATEGORY CATEGORY 1 DISCHARGE LOCA 770N: CITY MS4 /N DALEY STREET TYPE OF AREA SO. FT. STORMWA TER FACILITY LAWN & LANDSCAPE 4,077 SF SOIL AMENDMENTS T5.13 ROOFS 3,160 SF STORMWATER BMP DETENTION PIPE HARD SURFACES 1,084 SF STORMWATER BMP DETENTION PIPE SIDE SEWER NOTE EXISTING SEWER LATERAL TO BE REPLACED OR RELINED, WITH PREFERENCE TO RELINING WHEN TECHNICALLY FEASIBLE. THIS REQUIREMENT MAY BE WAIVED IF IT IS DEMONSTRATED THAT THE EXISTING SIDE SEWER AND LATERAL WAS CONSTRUCTED IN ACCORDANCE WITH THE CURRENT (AT THE TIME OF DEVELOPMENT) CITY STANDARDS. A VIDEO INSPECTION OF THE LATERAL SHALL BE PERFORMED BY THE CITY'S PUBLIC WORKS DEPARTMENT TO DETERMINE THE CONDITION OF THE LATERAL. PLEASE CONTACT ENG/NEERINGPERMITS®EDMONDSWA.GOV TO SCHEDULE AN INSPECTION. PATCH/NG/OVERLAY NOTE UTILITY PATCHES SHALL BE COMBINED AND FULL MI OR HALF W/D 7H 0 VERLA Y WILL BE REQUIRED DEPENDING ON 7HE EXTENT OF DISTURBANCE. WHERE U77LITY PATCHES FALL ENTIRELY W/7H/N ONE TRAVEL LANE, 7HE OVERLAY SHALL EXTEND TO 7HE CENTERLINE OF ROADWAY. WHERE UTILITY PATCHES EXTEND INTO BOTH TRAVEL LANES, THEN A FULL MD TV 0VERLA Y /S REQUIRED. BELL ST ST VICINITY MAP NOT TO SCALE PROJECT TEAM 0 a O OWNER/APPLICANT CIVIL ENGINEER w PETER AND SA TANG RAM ENGINEERING, INC. 648 BELL STREET 19109 367H AVE W, SUITE 100 EDMONDS, WA 98020 LYNNWOOD, WA 98036 (206)372-2584 (425) 678-6960 CONTACT' ROB L. LONG, PE SURVEYOR ROBL@RAMENGINEER/NGINC. COM PACIFIC COAST SURVEYS, INC. PO BOX 13619 MILL CREEK, WA 98082 (425) 512- 7099 CONTACT' DARREN J. RIDDLE LEGAL DESCRIPTION LOT 10, 11 AND THE WEST HALF OF LOT 12 /N BLOCK 81 OF CITY OF EDMONDS, ACCORDING TO THE PLAT THEREOF RECORDED /N VOLUME 2 OF PLATS AT PAGE 39, IN SNOHOMISH COUNTY, WASHINGTON. SITUATE /N THE CITY OF EDMONDS, COUNTY OF SNOHOMISH, STATE OF WASH/NGTON. BASIS OF BEARING NORTH 773220" EAST BETWEEN TWO FOUND MONUMENTS AS SHOWN. DATUM/BENCHMARK tUMII (M.L.L.W.) RAILROAD SPIKE IN EAST FACE OF POWER POLE ON THE NORTH SIDE OF GLEN ST. PER EDMONDS CREEKSIDE CONDO PH. 1. ELEVATION = 76.89' SURVEY REFERENCES (R1) RECORD OF SURVEY - AFN 201206225002 (R2) PLA T OF CITY OF EDMONDS - VOL. 2, PG. 39 (R3) EDMONDS CREEKSIDE (PHASE 1) CONDO - AFN 9006285011 NOTES 1. THIS SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF PARTIES WHOSE NAMES APPEAR HEREON ONLY, AND DOES NOT EXTEND TO ANY UNNAMED THIRD PARTIES WITHOUT EXPRESS RECERTIFICATION 8Y THE LAND SURVEYOR OF RECORD. 2. BOUNDARY LINES SHOWN AND CORNERS SET REPRESENT DEED LOCATIONS,• OWNERSHIP LINES MAY VARY. NO GUARANTEE OF OWNERSHIP IS EXPRESSED OR IMPLIED. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE REPORT AND DOES NOT PURPORT TO SHOW ALL EASEMENTS, RESTRICTIONS, RESERVATIONS, AND OCCUPATION WHICH MAY ENCUMBER TITLE OR USE OF SUBJECT PROPERTY. SITE DATA SITE ADDRESS: 840 DALEY ST, EDMONDS, WA 98020 TOTAL SITE AREA: 8,201 SF (0.19 AC) EXISTING ZONING: RS-6 AGENCIES/UTILITIES JURISDICTION CITY OF EDMONDS WATER DISTRICT CITY OF EDMONDS SEWER DISTRICT CITY OF EDMONDS STORM WA TER CITY OF EDMONDS SCHOOL DISTRICT EDMONDS SCHOOL DISTRICT NO. 15 FIRE DISTRICT SOUTH SNOHOMISH COUNTY FIRE & RESCUE TELEPHONE Z/PL Y ELECTRICAL SNOHOMISH COUNTY PUD NO. 1 GAS PSE GARBAGE SOUND DISPOSAL SHEET INDEX 1 SP-01 SITE DEVELOPMENT PLAN 2 GN-01 GENERAL NOTES & LEGEND 3 TP-01 CLEARING GRADING & TESC PLAN 4 DT-01 GENERAL DETAILS 5 DT-02 GENERAL DETAILS CONSTRUCT/ON NOTE APPLICANT SHALL REPA/R/RELACE ALL DAMAGE TO UTILITIES OR FRONTAGE IMPROVEMENTS /N C/TY RIGHT-OF-WAY PER CITY STANDARDS THAT IS CAUSED OR OCCURS DURING THE PERMITTED PROJECT. Know what's below. CBII before you dig. BLD2023-0443 APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY CITY ENGINEERING DIVISION ENGINEERING, INC. Civil Engineering / Land Planning RAM 19109 36TH AVE W, SUITE 100 LYNNWOOD, WA 98036 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM O o W LU O Z z LCJ Z � Z U U U U U U � Q- Q m WwW� n O� of WAS6, L p� .d 3Afi0A .. �W ENGINEER: Z Z Z f4 ROB L. LONG, PE DRAWN BY.• BRIAN CLARK ISSUE DATE.- SCALE.• 4/03/2J AS NOTED JOB NO. 23-002 SHEET' SP-0 1 SHT / OF 5