Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-0904_Manufacturer_Specifications_and_Installation_Instructions_7.11.2024_2.20.13_PM_4371795
Air Conditioning & Heating Standard Features • Energy -efficient compressor • SmartShift® technology to ensure quiet reliable defrost • Enhanced aluminum fin coil with 5 mm diameter copper tubes in 1.5- to 3.5-ton • Single -speed PSC condenser fan motor • Factory -installed bi-flow liquid -line filter drier • Factory -installed suction -line accumulator • Factory -installed compressor crankcase heater • Factory -installed high -capacity muffler • High- and low-pressure switches • Service valves with sweat connections and easy access to gauge ports • Fully charged for 15' of tubing length • Contactor with lug connection • Ground lug connection • AHRI Certified; ETL Listed GSZB4 ENERGY -EFFICIENT SPLIT SYSTEM HEAT PUMP 14.3 SEER2 & 7.5 HSPF2 1'z To 5 ToNs Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 Expanded Heating Data.......................18 Performance Data ............................... 20 Dimensions.......................................... 22 Wiring Diagram .................................... 23 Accessories .......................................... 25 Cabinet Features • Removable grille -style top design compliant with UL 60335-2-40 • Steel louver coil guard • Heavy -gauge galvanized -steel cabinet • Attractive Architectural Gray powder -paint finish with 500-hour salt -spray approval • Top and side maintenance access • When properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane -type winds (Anchor bracket kits available.) PARTS E L COMPANY WITH COMPANYWITH 10 LIMITED C \�I US GU FLED SYSTEM ENVIRONMENTAL SYSTEM CERTIFIED BV SYSTEM GL CERTIFIEDBYDNVGL TE YEAR WARRANTY'=1509001==150190a1= Intertek Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited BBB' Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. The duration of warranty coverages in Texas differs in some cases. SS-GSZB4 www.goodmanmfg.com 04/24 Supersedes 10/22 NOMENCLATURE G S Z B 1 2 Brand G Goodman® Brand Product Category S Split System R-410A unit i ype - apnt Dystem X Condenser Z Heat Pump Feature N Value H Enhanced B Classic C Premium M Multi -Family V Ultimate SEER2 13.4-13.7=3 16.6-17.5=7 13.8-14.5=4 17.6-18.5=8 14.6-15.5=5 18.6-19.5=9 15.6-16.5=6 19.6+=0 15.6 - 16.5 = 6 3 4 4 0 36 1 0 A A 5 6 7,8 9 10 11 12 Minor Rev A Major Rev A Variation 1 208/230 V, 1 Phase, 60 Hz Nominal Capacity 18 - 1% tons 42 - 3% Tons 24 - 2 tons 48 - 4 Tons 30 - 2% tons 60 - 5 Tons 36 - 3 tons Sales Region N North S Southeast & North 0 All Regions 2 www.goodmanmfg.com SS-GSZB4 PRODUCT SPECIFICATIONS 0A :4 GSZB4 04: GSZ134 0.0 NOMINAL CAPACITIES Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Heating (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Decibels 70 74 75 72 75 74 75 COMPRESSOR RLA 6.1 8.4 14.1 16.0 17.7 19.9 25.6 LRA 35.1 41.2 67.9 91.9 110.2 110.0 150.0 Stage Single Single Single Single Single Single Single Type Rotary Rotary Scroll Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type PSC PSC PSC PSC PSC PSC PSC Horsepower 1/6 1/6 1/6 1/6 1/4 1/4 1/4 FLA 0.95 0.95 0.95 0.97 1.3 1.3 1.3 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) %11 W %11 W. W, W. Suction Line Size ("O.D.) %" /" %8" 1%" 1y.. 1%8" Refrigerant Connection Size Liquid Valve Size ("O.D.) %" W W, W W. %11 W. Suction Valve Size ("O.D.) %" %" %" 3/8" 7/81' W Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge (oz.) 94 92 94 114 167 222 269 ELECTRICAL DATA Volts/Phase (60 Hz) 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum Circuit Ampacity 2 8.6 11.5 18.6 21 23.4 26.2 33.3 Max. Overcurrent Protection 3 15 15 30 35 40 45 50 Min/ Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" UNIT WEIGHTS Equipment Weight (Ibs.) 161 160 175 214 264 272 305 Ship Weight (lbs) 176 175 190 234 284 292 325 ' Tested and rated in accordance with ARI Standard 210/240 z Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes 3 Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. NOTES • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply%" to 1%" adapters for suction line connections. • Unit is charged with refrigerant for 15' of W liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-GSZB4 www.goodmanmfg.com 0 0 0 0_ 3 v 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 17.3 17.5 18.0 - 17.1 17.4 17.9 - 16.7 16.9 17.4 - 15.9 16.1 16.6 - 14.9 15.2 15.7 - 14.1 14.3 14.8 - S/T 0.59 0.52 0.38 0.60 0.52 0.39 0.62 0.55 0.41 1.00 0.57 0.43 1.00 0.59 0.45 1.00 0.64 0.51 AT 19 17 14 19 17 14 19 17 14 19 17 14 18 17 13 19 18 15 525 kW 1.04 1.03 1.03 1.15 1.15 1.15 1.28 1.28 1.28 1.42 1.42 1.42 1.58 1.58 1.58 1.77 1.76 1.76 Amps 4.0 4.0 4.0 4.5 4.5 4.5 5.1 5.1 5.1 5.8 5.8 5.8 6.5 6.5 6.5 7.3 7.3 7.3 HiPR 234 235 236 271 272 273 309 310 312 351 352 354 396 397 398 444 445 446 Lo PR 125 127 130 133 134 137 139 141 144 145 146 150 150 152 155 157 159 162 MBh 17.5 17.8 18.3 17.4 17.6 18.1 16.9 17.2 17.7 16.1 16.4 16.9 15.2 15.4 16.0 14.3 14.6 15.1 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.66 0.53 1.00 0.71 0.58 AT 17 16 13 17 16 12 18 16 13 17 16 12 17 15 12 18 16 13 70 615 kW 1.04 1.04 1.04 1.16 1.16 1.16 1.29 1.29 1.29 1.43 1.43 1.43 1.59 1.59 1.58 1.77 1.77 1.77 Amps 4.0 4.0 4.0 4.6 4.6 4.6 5.2 5.2 5.2 5.8 5.8 5.8 6.5 6.5 6.5 7.4 7.4 7.4 HiPR 236 237 239 273 274 276 312 313 314 353 354 356 398 399 401 446 447 449 Lo PR 127 129 132 135 136 139 141 143 146 147 149 152 153 154 157 160 161 164 MBh 17.7 18.0 18.5 17.6 17.8 18.3 17.1 17.4 17.9 16.3 16.6 17.1 15.4 15.6 16.2 14.5 14.8 15.3 S/T 0.70 0.62 0.48 0.70 0.63 0.49 0.73 0.65 0.51 1.00 0.67 0.53 1.00 0.69 0.56 1.00 0.74 0.61 AT 17 15 12 17 15 12 17 15 12 17 15 12 16 15 12 18 16 13 675 kW 1.05 1.05 1.04 1.16 1.16 1.16 1.29 1.29 1.29 1.43 1.43 1.43 1.59 1.59 1.59 1.78 1.78 1.77 Amps 4.1 4.1 4.0 4.6 4.6 4.6 5.2 5.2 5.2 5.8 5.8 5.8 6.6 6.5 6.5 7.4 7.4 7.4 HiPR 237 238 240 274 275 277 313 314 316 355 356 357 400 401 402 448 449 450 Lo PR 129 130 133 136 138 141 143 145 148 149 150 153 154 156 159 161 163 166 MBh 17.3 17.5 18.0 18.8 17.1 17.4 17.9 18.7 16.7 16.9 17.4 18.2 15.9 16.1 16.6 17.4 14.9 15.2 15.7 16.5 14.1 14.3 14.8 15.6 S/T 0.72 0.65 0.51 0.37 0.73 0.65 0.52 0.37 1.00 0.68 0.54 0.40 1.00 0.70 0.56 0.42 1.00 0.72 0.58 0.44 1.00 1.00 0.64 0.49 AT 22 21 18 14 22 21 17 14 23 21 18 14 22 21 17 14 22 20 17 14 23 21 18 15 525 kW 1.03 1.03 1.03 1.04 1.15 1.15 1.15 1.16 1.28 1.28 1.28 1.29 1.42 1.42 1.42 1.43 1.58 1.58 1.58 1.59 1.76 1.76 1.76 1.77 Amps 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.6 5.1 5.1 5.1 5.2 5.8 5.8 5.8 5.8 6.5 6.5 6.5 6.5 7.3 7.3 7.3 7.4 Hi PR 234 235 236 241 271 272 273 277 309 310 312 316 351 352 354 358 396 397 399 403 444 445 447 451 Lo PR 125 127 130 135 133 134 137 143 139 141 144 149 145 146 150 155 150 152 155 161 157 159 162 167 MBh 17.5 17.8 18.3 19.1 17.4 17.6 18.1 18.9 16.9 17.2 17.7 18.5 16.1 16.4 16.9 17.7 15.2 15.4 16.0 16.7 14.3 14.6 15.1 15.9 S/T 0.80 0.72 0.58 0.44 1.00 0.73 0.59 0.45 1.00 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 1.00 0.71 0.57 AT 21 19 16 13 21 19 16 13 21 20 16 13 21 19 16 13 21 19 16 13 22 20 17 14 75 615 kW 1.04 1.04 1.04 1.05 1.16 1.16 1.16 1.16 1.29 1.29 1.29 1.29 1.43 1.43 1.43 1.44 1.59 1.59 1.58 1.59 1.77 1.77 1.77 1.78 Amps 4.0 4.0 4.0 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.8 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.4 HIM 236 237 239 243 273 274 276 280 312 313 314 319 353 354 356 360 398 399 401 405 446 447 449 453 Lo PR 127 129 132 137 135 136 139 145 141 143 146 151 147 149 152 157 153 154 157 163 160 161 164 170 MBh 17.7 18.0 18.5 19.3 17.6 17.8 18.3 19.1 17.1 17.4 17.9 18.7 16.4 16.6 17.1 17.9 15.4 15.7 16.2 17.0 14.5 14.8 15.3 16.1 S/T 0.82 0.75 0.61 0.47 1.00 0.75 0.62 0.48 1.00 0.78 0.64 0.50 1.00 0.80 0.66 0.52 1.00 1.00 0.69 0.54 1.00 1.00 0.74 0.59 AT 20 19 16 12 20 19 16 12 21 19 16 12 20 19 16 12 20 18 15 12 21 20 16 13 675 kW 1.05 1.04 1.04 1.05 1.16 1.16 1.16 1.17 1.29 1.29 1.29 1.30 1.43 1.43 1.43 1.44 1.59 1.59 1.59 1.60 1.78 1.77 1.77 1.78 Amps 4.1 4.0 4.0 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.9 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.4 HiPR 238 239 240 244 275 276 277 281 313 314 316 320 355 356 358 362 400 401 402 407 448 449 450 454 Lo PR 129 130 133 139 136 138 141 146 143 145 148 153 149 150 153 159 154 156 159 164 161 163 166 171 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 17.4 17.6 18.1 18.9 17.2 17.4 18.0 18.8 16.8 17.0 17.5 18.3 16.0 16.2 16.7 17.5 15.0 15.3 15.8 16.6 14.2 14.4 14.9 15.7 S/T 1.00 0.77 0.64 0.49 1.00 0.78 0.64 0.50 1.00 0.80 0.67 0.52 1.00 1.00 0.69 0.54 1.00 1.00 0.71 0.57 1.00 1.00 0.76 0.62 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 18 27 25 22 19 525 kW 1.04 1.03 1.03 1.04 1.15 1.15 1.15 1.16 1.28 1.28 1.28 1.29 1.42 1.42 1.42 1.43 1.58 1.58 1.58 1.59 1.77 1.76 1.76 1.77 Amps 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.6 5.1 5.1 5.1 5.2 5.8 5.8 5.8 5.8 6.5 6.5 6.5 6.5 7.3 7.3 7.3 7.4 HIM 234 235 237 241 271 272 274 278 310 311 313 317 352 353 354 358 396 397 399 403 444 445 447 451 Lo PR 126 127 130 136 133 135 138 143 140 141 145 150 145 147 150 156 151 153 156 161 158 160 163 168 MBh 17.6 17.9 18.4 19.2 17.5 17.7 18.2 19.0 17.0 17.3 17.8 18.6 16.2 16.5 17.0 17.8 15.3 15.5 16.1 16.8 14.4 14.7 15.2 16.0 S/T 1.00 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 1.00 0.76 0.62 1.00 1.00 0.78 0.64 1.00 1.00 0.83 0.69 AT 25 23 20 17 25 23 20 17 25 23 20 17 25 23 20 17 25 23 20 16 26 24 21 18 80 615 kW 1.04 1.04 1.04 1.05 1.16 1.16 1.16 1.16 1.29 1.29 1.29 1.30 1.43 1.43 1.43 1.44 1.59 1.59 1.58 1.59 1.77 1.77 1.77 1.78 Amps 4.0 4.0 4.0 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.8 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.4 Hi PR 237 238 239 243 274 275 276 280 312 313 315 319 354 355 357 361 399 400 401 405 447 448 449 453 Lo PR 128 129 132 138 135 137 140 145 142 144 147 152 148 149 152 158 153 155 158 163 160 162 165 170 MBh 17.8 18.1 18.6 19.4 17.7 17.9 18.4 19.2 17.2 17.5 18.0 18.8 16.4 16.7 17.2 18.0 15.5 15.7 16.3 17.0 14.6 14.9 15.4 16.2 S/T 1.00 0.87 0.74 0.59 1.00 0.88 0.74 0.60 1.00 0.91 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72 AT 24 23 19 16 24 23 19 16 24 23 20 16 24 22 19 16 24 22 19 16 25 23 20 17 675 kW 1.05 1.05 1.04 1.05 1.16 1.16 1.16 1.17 1.29 1.29 1.29 1.30 1.43 1.43 1.43 1.44 1.59 1.59 1.59 1.60 1.78 1.78 1.77 1.78 Amps 4.1 4.1 4.0 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.9 6.6 6.5 6.5 6.6 7.4 7.4 7.4 7.4 Hi PR 238 239 241 245 275 276 278 282 314 315 316 320 355 356 358 362 400 401 403 407 448 449 451 455 Lo PR 1 129 131 134 139 137 138 142 147 144 145 148 154 149 151 154 159 155 156 159 165 162 163 166 172 MBh 17.7 17.9 18.4 19.2 17.5 17.7 18.3 19.0 17.0 17.3 17.8 18.6 16.3 16.5 17.0 17.8 15.3 15.6 16.1 16.9 14.5 14.7 15.2 16.0 S/T 1.00 0.87 0.74 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.81 0.7 1.00 1.00 1.00 0.7 AT 30 28 25 21 29 28 25 21 30 28 25 22 29 28 25 21 29 28 24 21 30 29 25 22 525 kW 1.04 1.04 1.03 1.0 1.15 1.15 1.15 1.2 1.28 1.28 1.28 1.3 1.43 1.42 1.42 1.4 1.58 1.58 1.58 1.6 1.77 1.77 1.76 1.8 Amps 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.6 5.1 5.1 5.1 5.2 5.8 5.8 5.8 5.8 6.5 6.5 6.5 6.5 7.4 7.4 7.3 7.4 Hi PR 235 236 238 242 272 273 275 279 311 312 314 318 353 354 355 359 398 399 400 404 445 446 448 452 Lo PR 127 129 132 137 135 137 140 145 142 143 146 152 147 149 152 157 153 154 158 163 160 161 165 170 MBh 17.9 18.2 18.7 19.5 17.8 18.0 18.5 19.3 17.3 17.6 18.1 18.9 16.5 16.8 17.3 18.1 15.6 15.8 16.3 17.1 14.7 15.0 15.5 16.3 S/T 1.00 0.95 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8 AT 28 27 23 20 28 27 23 20 28 27 24 20 28 27 23 20 28 26 23 20 29 27 24 21 85 615 kW 1.04 1.04 1.04 1.1 1.16 1.16 1.16 1.2 1.29 1.29 1.29 1.3 1.43 1.43 1.43 1.4 1.59 1.59 1.59 1.6 1.77 1.77 1.77 1.8 Amps 4.0 4.0 4.0 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.9 6.5 6.5 6.5 6.6 7.4 7.4 7.4 7.4 Hi PR 238 239 240 244 275 276 277 281 313 314 316 320 355 356 358 362 400 401 403 407 448 449 450 455 Lo PR 130 131 134 140 137 139 142 147 144 145 149 154 150 151 154 160 155 157 160 165 162 164 167 172 MBh 18.1 18.4 18.9 19.7 18.0 18.2 18.7 19.5 17.5 17.8 18.3 19.1 16.7 17.0 17.5 18.3 15.8 16.0 16.6 17.3 14.9 15.2 15.7 16.5 S/T 1.00 0.98 0.84 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 1.00 1.00 1.00 0.8 4T 28 26 23 19 28 26 23 19 28 26 23 20 28 26 23 19 27 26 22 19 28 27 23 20 675 kW 1.05 1.05 1.05 1.1 1.17 1.16 1.16 1.2 1.30 1.29 1.29 1.3 1.44 1.44 1.43 1.4 1.59 1.59 1.59 1.6 1.78 1.78 1.78 1.8 Amps 4.1 4.1 4.1 4.1 4.6 4.6 4.6 4.6 5.2 5.2 5.2 5.2 5.8 5.8 5.8 5.9 6.6 6.6 6.5 6.6 7.4 7.4 7.4 7.4 HIM 239 240 242 246 276 277 279 283 315 316 317 322 356 357 359 363 401 402 404 408 449 450 452 456 Lo PR 131 133 136 141 139 140 143 149 145 147 150 156 151 153 156 161 157 158 161 167 164 165 168 174 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor +fan) k n z 0 m n O O z 'z G) QD IN n G) Cn N 00 O I" 00 N O 0 0 0 0_ 3 v 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 23.0 23.4 24.1 - 22.8 23.2 23.8 - 22.2 22.6 23.2 - 21.2 21.5 22.2 - 19.9 20.3 21.0 - 18.8 19.1 19.8 - S/T 0.61 0.54 0.40 0.62 0.54 0.41 0.64 0.57 0.43 0.66 0.59 0.45 1.00 0.61 0.47 1.00 0.66 0.53 AT 18 17 13 18 17 13 18 17 14 18 16 13 18 16 13 19 17 14 700 kW 1.35 1.35 1.35 1.52 1.52 1.51 1.70 1.70 1.69 1.90 1.89 1.89 2.12 2.11 2.11 2.37 2.37 2.37 Amps 5.3 5.3 5.3 6.0 6.0 6.0 6.9 6.8 6.8 7.8 7.7 7.7 8.8 8.8 8.7 9.9 9.9 9.9 HIM 241 242 244 279 280 282 319 320 322 362 363 365 408 409 411 457 459 460 Lo PR 1 122 123 126 129 131 134 136 137 140 141 143 146 147 148 151 153 155 158 MBh 23.3 23.6 24.3 23.1 23.4 24.1 22.5 22.8 23.5 21.5 21.8 22.5 20.2 20.5 21.2 19.0 19.4 20.1 S/T 0.66 0.58 0.45 0.66 0.59 0.45 0.69 0.61 0.48 0.71 0.63 0.50 1.00 0.65 0.52 1.00 0.71 0.57 AT 17 16 13 17 16 12 18 16 13 17 16 12 17 15 12 18 17 13 70 780 kW 1.36 1.36 1.36 1.52 1.52 1.52 1.71 1.70 1.70 1.90 1.90 1.90 2.12 2.12 2.12 2.38 2.38 2.38 Amps 5.3 5.3 5.3 6.1 6.0 6.0 6.9 6.9 6.9 7.8 7.8 7.8 8.8 8.8 8.8 10.0 10.0 10.0 HiPR 243 244 246 281 282 284 321 322 323 364 365 366 410 411 413 459 460 462 Lo PR 123 125 128 131 132 135 137 139 142 143 144 147 148 150 153 155 156 159 MBh 23.8 24.1 24.8 23.5 23.9 24.6 22.9 23.3 24.0 21.9 22.2 22.9 20.6 21.0 21.7 19.5 19.8 20.5 S/T 0.70 0.62 0.49 0.70 0.63 0.49 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.69 0.56 1.00 0.74 0.61 AT 16 15 11 16 15 11 17 15 12 16 15 11 16 14 11 17 15 12 900 kW 1.37 1.37 1.37 1.53 1.53 1.53 1.71 1.71 1.71 1.91 1.91 1.91 2.13 2.13 2.13 2.39 2.39 2.38 Amps 5.4 5.3 5.3 6.1 6.1 6.1 6.9 6.9 6.9 7.8 7.8 7.8 8.8 8.8 8.8 10.0 10.0 10.0 HiPR 245 246 248 283 284 286 323 324 326 366 367 369 412 413 415 462 463 464 Lo PR 1 126 127 130 133 135 138 140 141 144 145 147 150 150 152 155 157 159 162 MBh 23.1 23.4 24.1 25.1 22.9 23.2 23.9 24.9 22.3 22.6 23.3 24.3 21.2 21.5 22.2 23.3 20.0 20.3 21.0 22.0 18.8 19.1 19.8 20.9 S/T 0.74 0.66 0.53 0.39 0.75 0.67 0.54 0.39 1.00 0.69 0.56 0.42 1.00 0.71 0.58 0.44 1.00 0.74 0.60 0.46 1.00 1.00 0.65 0.51 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 14 23 21 18 15 700 kW 1.35 1.35 1.35 1.36 1.52 1.51 1.51 1.52 1.70 1.70 1.69 1.71 1.89 1.89 1.89 1.90 2.11 2.11 2.11 2.12 2.37 2.37 2.37 2.38 Amps 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.1 6.9 6.8 6.8 6.9 7.8 7.7 7.7 7.8 8.8 8.7 8.7 8.8 9.9 9.9 9.9 10.0 HiPR 241 242 244 248 279 280 282 286 319 320 322 326 362 363 365 369 408 409 411 415 458 459 460 465 Lo PR 122 123 126 132 129 131 134 139 136 137 140 145 141 143 146 151 147 148 151 156 153 155 158 163 MBh 23.3 23.6 24.3 25.4 23.1 23.4 24.1 25.2 22.5 22.8 23.5 24.6 21.5 21.8 22.5 23.5 20.2 20.5 21.2 22.3 19.1 19.4 20.1 21.1 S/T 0.79 0.71 0.58 0.44 0.79 0.72 0.58 0.44 1.00 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 1.00 0.70 0.56 AT 21 19 16 13 21 19 16 13 21 20 16 13 21 19 16 13 21 19 16 13 22 20 17 14 75 780 kW 1.36 1.36 1.36 1.37 1.52 1.52 1.52 1.53 1.70 1.70 1.70 1.71 1.90 1.90 1.90 1.91 2.12 2.12 2.12 2.13 2.38 2.38 2.37 2.39 Amps 5.3 5.3 5.3 5.3 6.1 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.8 10.0 10.0 9.9 10.0 HiPR 243 244 246 250 281 282 284 288 321 322 324 328 364 365 367 371 410 411 413 417 459 460 462 466 Lo PR 123 125 128 133 131 132 135 140 137 139 142 147 143 144 147 152 148 150 153 158 155 156 159 165 MBh 23.8 24.1 24.8 25.8 23.6 23.9 24.6 25.6 23.0 23.3 24.0 25.0 21.9 22.3 22.9 24.0 20.7 21.0 21.7 22.7 19.5 19.8 20.5 21.6 S/T 0.82 0.75 0.61 0.47 1.00 0.75 0.62 0.48 1.00 0.78 0.65 0.50 1.00 0.80 0.66 0.52 1.00 0.82 0.69 0.54 1.00 1.00 0.74 0.60 AT 20 18 15 12 20 18 15 12 20 19 15 12 20 18 15 12 20 18 15 12 21 19 16 13 900 kW 1.37 1.37 1.36 1.38 1.53 1.53 1.53 1.54 1.71 1.71 1.71 1.72 1.91 1.91 1.91 1.92 2.13 2.13 2.13 2.14 2.39 2.39 2.38 2.40 Amps 5.3 5.3 5.3 5.4 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 HiPR 246 247 248 252 284 285 286 290 323 324 326 330 366 367 369 373 412 414 415 419 462 463 465 469 Lo PR 126 127 130 136 133 135 138 143 140 141 144 149 145 147 150 155 151 152 155 160 157 159 162 167 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n C) N O Ni H ti C N O 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE Di MBh 23.2 23.5 24.2 25.2 23.0 23.3 24.0 25.0 22.4 22.7 23.4 24.4 21.3 21.7 22.3 23.4 20.1 20.4 21.1 22.1 18.9 19.2 19.9 21.0 S/T 0.86 0.79 0.65 0.51 1.00 0.79 0.66 0.52 1.00 0.82 0.68 0.54 1.00 0.84 0.70 0.56 1.00 1.00 0.73 0.58 1.00 1.00 0.78 0.64 AT 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 17 27 25 22 18 700 kW 1.35 1.35 1.35 1.36 1.52 1.52 1.51 1.53 1.70 1.70 1.69 1.71 1.90 1.89 1.89 1.90 2.11 2.11 2.11 2.12 2.37 2.37 2.37 2.38 Amps 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.1 6.9 6.8 6.8 6.9 7.8 7.7 7.7 7.8 8.8 8.8 8.7 8.8 9.9 9.9 9.9 10.0 Hi PR 242 243 245 249 280 281 283 287 320 321 322 327 363 364 365 370 409 410 412 416 458 459 461 465 Lo PR 122 124 127 132 130 131 134 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 164 MBh 23.4 23.8 24.4 25.5 23.2 23.5 24.2 25.3 22.6 22.9 23.6 24.7 21.6 21.9 22.6 23.6 20.3 20.7 21.3 22.4 19.2 19.5 20.2 21.2 S/T 1.00 0.83 0.70 0.56 1.00 0.84 0.71 0.57 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 1.00 0.77 0.63 1.00 1.00 0.82 0.68 AT 25 23 20 17 25 23 20 17 25 23 20 17 25 23 20 17 25 23 20 16 26 24 21 18 80 780 kW 1.36 1.36 1.36 1.37 1.52 1.52 1.52 1.53 1.71 1.70 1.70 1.71 1.90 1.90 1.90 1.91 2.12 2.12 2.12 2.13 2.38 2.38 2.38 2.39 Amps 5.3 5.3 5.3 5.3 6.1 6.0 6.0 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.8 10.0 10.0 10.0 10.0 Hi PR 244 245 246 250 282 283 284 288 321 322 324 328 364 365 367 371 410 412 413 417 460 461 463 467 Lo PR 124 125 128 134 131 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 MBh 23.9 24.2 24.9 25.9 23.7 24.0 24.7 25.7 23.1 23.4 24.1 25.1 22.0 22.4 23.1 24.1 20.8 21.1 21.8 22.8 19.6 20.0 20.6 21.7 S/T 1.00 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 15 25 23 20 16 900 kW 1.37 1.37 1.37 1.38 1.53 1.53 1.53 1.54 1.71 1.71 1.71 1.72 1.91 1.91 1.91 1.92 2.13 2.13 2.13 2.14 2.39 2.39 2.38 2.40 Amps 5.3 5.3 5.3 5.4 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.0 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 369 374 413 414 416 420 462 463 465 469 Lo PR 1 126 128 131 136 134 135 138 143 140 142 145 150 146 147 150 155 151 153 156 161 158 159 162 168 700 MBh S/T AT kW Amps Hi PR Lo PR 23.6 1.00 29 1.36 5.3 243 124 23.9 0.89 27 1.36 5.3 244 126 24.6 0.75 24 1.35 5.3 246 129 25.6 0.6 21 1.4 5.3 250 134 23.4 1.00 29 1.52 6.0 281 132 23.7 0.89 27 1.52 6.0 282 133 24.4 0.76 24 1.52 6.0 284 136 25.4 0.6 21 1.5 6.1 288 141 22.8 1.00 29 1.70 6.9 321 138 23.1 1.00 28 1.70 6.9 322 140 23.8 0.78 24 1.70 6.9 324 143 24.8 0.6 21 1.7 6.9 328 148 21.7 1.00 29 1.90 7.8 364 144 22.0 1.00 27 1.90 7.8 365 145 22.7 0.80 24 1.89 7.7 366 148 23.8 0.7 21 1.9 7.8 371 153 20.5 1.00 29 2.12 8.8 410 149 20.8 1.00 27 2.12 8.8 411 150 21.5 0.83 24 2.11 8.8 413 154 22.5 0.7 21 2.1 8.8 417 159 19.3 1.00 30 2.38 10.0 459 156 19.6 1.00 28 2.37 9.9 460 157 20.3 1.00 25 2.37 9.9 462 160 21.4 0.7 22 2.4 10.0 466 165 MBh 23.8 24.1 24.8 25.9 23.6 23.9 24.6 25.7 23.0 23.3 24.0 25.1 22.0 22.3 23.0 24.0 20.7 21.0 21.7 22.8 19.6 19.9 20.6 21.6 S/T 1.00 0.93 0.80 0.7 1.00 0.94 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 1.00 0.8 AT 28 27 23 20 28 27 23 20 29 27 24 20 28 27 23 20 28 26 23 20 29 27 24 21 85 780 kW 1.36 1.36 1.36 1.4 1.53 1.53 1.52 1.5 1.71 1.71 1.70 1.7 1.91 1.90 1.90 1.9 2.12 2.12 2.12 2.1 2.38 2.38 2.38 2.4 Amps 5.3 5.3 5.3 5.4 6.1 6.1 6.1 6.1 6.9 6.9 6.9 6.9 7.8 7.8 7.8 7.8 8.8 8.8 8.8 8.8 10.0 10.0 10.0 10.0 Hi PR 245 246 247 252 283 284 285 290 323 324 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 126 127 130 135 133 135 138 143 140 141 144 149 145 147 150 155 150 152 155 160 157 159 162 167 MBh 24.3 24.6 25.3 26.3 24.1 24.4 25.1 26.1 23.5 23.8 24.5 25.5 22.4 22.8 23.4 24.5 21.2 21.5 22.2 23.2 20.0 20.3 21.0 22.1 S/T 1.00 0.97 0.84 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.91 0.8 1.00 1.00 1.00 0.8 AT 27 26 22 19 27 26 22 19 27 26 23 19 27 25 22 19 27 25 22 19 28 26 23 20 900 kW 1.37 1.37 1.37 1.4 1.54 1.53 1.53 1.5 1.72 1.72 1.71 1.7 1.91 1.91 1.91 1.9 2.13 2.13 2.13 2.1 2.39 2.39 2.39 2.4 Amps 5.4 5.4 5.3 5.4 6.1 6.1 6.1 6.1 6.9 6.9 6.9 7.0 7.8 7.8 7.8 7.9 8.8 8.8 8.8 8.9 10.0 10.0 10.0 10.1 Hi PR 247 248 250 254 285 286 288 292 325 326 328 332 368 369 371 375 414 415 417 421 463 464 466 470 Lo PR 128 130 133 138 136 137 140 145 142 144 147 152 147 149 152 157 153 154 157 163 160 161 164 169 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) k n z 0 m n O O r- 'z G) QD IN n G) N 00 O ti N O 0 0 0 0_ 3 of 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 28.5 28.9 29.8 - 28.3 28.7 29.5 - 27.5 27.9 28.8 - 26.2 26.6 27.5 - 24.7 25.1 25.9 - 23.2 23.6 24.5 - S/T 0.60 0.52 0.38 0.61 0.52 0.38 0.63 0.55 0.41 0.65 0.57 0.43 1.00 0.60 0.45 1.00 0.65 0.51 AT 18 17 14 18 17 13 18 17 14 18 17 13 18 16 13 19 17 14 875 kW 1.70 1.70 1.69 1.90 1.89 1.89 2.12 2.12 2.11 2.36 2.36 2.35 2.63 2.62 2.62 2.94 2.94 2.93 Amps 6.3 6.3 6.3 7.2 7.2 7.2 8.2 8.2 8.2 9.3 9.3 9.3 10.5 10.5 10.5 12.0 12.0 11.9 HiPR 247 248 250 286 287 289 327 328 330 371 372 374 418 419 421 469 470 472 Lo PR 1 119 121 124 127 128 131 133 135 138 139 140 143 144 145 148 151 152 155 MBh 28.9 29.3 30.1 28.6 29.0 29.9 27.9 28.3 29.1 26.6 27.0 27.8 25.0 25.4 26.3 23.6 24.0 24.8 S/T 0.67 0.59 0.45 0.68 0.60 0.46 0.71 0.63 0.48 0.73 0.65 0.50 1.00 0.67 0.53 1.00 0.72 0.58 AT 17 16 12 17 16 12 17 16 13 17 15 12 17 15 12 18 16 13 70 1000 kW 1.71 1.71 1.70 1.91 1.90 1.90 2.13 2.13 2.12 2.37 2.37 2.36 2.64 2.63 2.63 2.95 2.95 2.95 Amps 6.3 6.3 6.3 7.2 7.2 7.2 8.3 8.2 8.2 9.4 9.3 9.3 10.6 10.6 10.6 12.0 12.0 12.0 HiPR 249 250 252 288 289 291 329 330 332 373 374 376 420 421 423 471 472 474 Lo PR 121 123 126 128 130 133 135 136 139 140 142 145 146 147 150 152 154 157 MBh 29.1 29.5 30.3 28.8 29.2 30.1 28.1 28.5 29.3 26.8 27.2 28.0 25.2 25.6 26.5 23.8 24.2 25.0 S/T 0.70 0.62 0.48 0.71 0.63 0.49 0.73 0.65 0.51 0.76 0.67 0.53 1.00 0.70 0.56 1.00 0.75 0.61 AT 17 15 12 17 15 12 17 15 12 17 15 12 16 15 12 17 16 13 1070 kW 1.71 1.71 1.71 1.91 1.91 1.91 2.13 2.13 2.13 2.37 2.37 2.37 2.64 2.64 2.64 2.96 2.95 2.95 Amps 6.4 6.3 6.3 7.3 7.3 7.2 8.3 8.3 8.3 9.4 9.4 9.4 10.6 10.6 10.6 12.0 12.0 12.0 HiPR 250 251 253 289 290 292 330 331 333 374 375 377 422 423 424 472 473 475 Lo PR 122 124 127 129 131 134 136 137 140 141 143 146 146 148 151 153 155 158 MBh 28.6 29.0 29.8 31.1 28.3 28.7 29.6 30.9 27.5 28.0 28.8 30.1 26.3 26.7 27.5 28.8 24.7 25.1 25.9 27.3 23.2 23.7 24.5 25.8 S/T 0.73 0.65 0.51 0.36 0.74 0.66 0.52 0.37 1.00 0.69 0.54 0.39 1.00 0.71 0.57 0.41 1.00 0.73 0.59 0.44 1.00 0.79 0.64 0.49 AT 22 20 17 14 22 20 17 14 22 20 17 14 22 20 17 14 22 20 17 14 23 21 18 15 875 kW 1.70 1.69 1.69 1.71 1.89 1.89 1.89 1.90 2.12 2.11 2.11 2.13 2.36 2.35 2.35 2.37 2.62 2.62 2.62 2.63 2.94 2.94 2.93 2.95 Amps 6.3 6.3 6.3 6.3 7.2 7.2 7.2 7.2 8.2 8.2 8.2 8.2 9.3 9.3 9.3 9.3 10.5 10.5 10.5 10.6 12.0 12.0 11.9 12.0 HiPR 247 248 250 254 286 287 289 293 327 328 330 334 371 372 374 378 419 420 421 426 469 470 472 476 Lo PR 120 121 124 129 127 128 131 136 133 135 138 143 139 140 143 148 144 145 149 154 151 152 155 160 MBh 28.9 29.3 30.1 31.4 28.6 29.0 29.9 31.2 27.9 28.3 29.1 30.4 26.6 27.0 27.8 29.2 25.0 25.4 26.3 27.6 23.6 24.0 24.8 26.1 S/T 0.81 0.73 0.59 0.43 0.81 0.73 0.59 0.44 1.00 0.76 0.62 0.47 1.00 0.78 0.64 0.49 1.00 0.80 0.66 0.51 1.00 0.86 0.72 0.57 AT 21 19 16 13 21 19 16 13 21 19 16 13 21 19 16 13 21 19 16 13 22 20 17 14 75 1000 kW 1.71 1.71 1.70 1.72 1.91 1.90 1.90 1.92 2.13 2.13 2.12 2.14 2.37 2.37 2.36 2.38 2.63 2.63 2.63 2.64 2.95 2.95 2.94 2.96 Amps 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.3 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 HiPR 249 250 252 256 288 289 291 295 329 330 332 336 373 374 376 380 421 422 423 428 471 472 474 479 Lo PR 121 123 126 131 128 130 133 138 135 136 139 145 140 142 145 150 146 147 150 155 152 154 157 162 MBh 29.1 29.5 30.3 31.7 28.8 29.2 30.1 31.4 28.1 28.5 29.3 30.6 26.8 27.2 28.1 29.4 25.2 25.6 26.5 27.8 23.8 24.2 25.0 26.3 S/T 0.84 0.76 0.61 0.46 0.84 0.76 0.62 0.47 1.00 0.79 0.65 0.50 1.00 0.81 0.67 0.52 1.00 0.83 0.69 0.54 1.00 1.00 0.75 0.60 AT 20 19 16 12 20 19 16 12 20 19 16 13 20 19 16 12 20 18 15 12 21 19 16 13 1070 kW 1.71 1.71 1.71 1.72 1.91 1.91 1.91 1.92 2.13 2.13 2.13 2.14 2.37 2.37 2.37 2.38 2.64 2.64 2.63 2.65 2.95 2.95 2.95 2.96 Amps 6.4 6.3 6.3 6.4 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 HiPR 250 251 253 257 289 290 292 296 330 331 333 337 374 375 377 381 422 423 425 429 472 474 475 480 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 143 146 151 147 148 151 156 153 155 158 163 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n C) N O Uj O H 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 28.7 29.1 30.0 31.3 28.4 28.9 29.7 31.0 27.7 28.1 29.0 30.3 26.4 26.8 27.7 29.0 24.8 25.2 26.1 27.4 23.4 23.8 24.7 26.0 S/T 0.87 0.79 0.64 0.49 1.00 0.79 0.65 0.50 1.00 0.82 0.68 0.53 1.00 0.84 0.70 0.55 1.00 1.00 0.72 0.57 1.00 1.00 0.77 0.62 AT 25 24 21 18 25 24 21 18 26 24 21 18 25 24 21 18 25 24 20 17 26 25 21 18 875 kW 1.70 1.70 1.69 1.71 1.90 1.89 1.89 1.91 2.12 2.12 2.11 2.13 2.36 2.36 2.35 2.37 2.63 2.62 2.62 2.64 2.94 2.94 2.93 2.95 Amps 6.3 6.3 6.3 6.3 7.2 7.2 7.2 7.2 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.5 10.5 10.5 10.6 12.0 12.0 11.9 12.0 Hi PR 247 248 250 254 286 288 289 294 327 328 330 335 372 373 374 379 419 420 422 426 470 471 473 477 Lopg 120 122 125 130 127 129 132 137 134 135 138 143 139 141 144 149 144 146 149 154 151 153 156 161 MBh 29.0 29.4 30.3 31.6 28.8 29.2 30.0 31.3 28.0 28.4 29.3 30.6 26.7 27.1 28.0 29.3 25.2 25.6 26.4 27.7 23.7 24.1 25.0 26.3 S/T 0.94 0.86 0.72 0.57 1.00 0.87 0.72 0.57 1.00 0.89 0.75 0.60 1.00 0.91 0.77 0.62 1.00 1.00 0.79 0.64 1.00 1.00 0.85 0.70 AT 24 23 20 17 24 23 20 17 25 23 20 17 24 23 20 16 24 22 19 16 25 24 20 17 80 1000 kW 1.71 1.71 1.70 1.72 1.91 1.90 1.90 1.92 2.13 2.13 2.12 2.14 2.37 2.37 2.36 2.38 2.64 2.63 2.63 2.65 2.95 2.95 2.95 2.96 Amps 6.3 6.3 6.3 6.4 7.2 7.2 7.2 7.3 8.3 8.2 8.2 8.3 9.4 9.3 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 Hi PR 249 250 252 257 289 290 291 296 329 331 332 337 374 375 376 381 421 422 424 428 472 473 475 479 LoPIR 122 123 126 131 129 130 134 139 135 137 140 145 141 142 145 150 146 148 151 156 153 154 157 162 MBh 29.2 29.6 30.5 31.8 29.0 29.4 30.2 31.5 28.2 28.6 29.5 30.8 26.9 27.3 28.2 29.5 25.4 25.8 26.6 27.9 23.9 24.3 25.2 26.5 S/T 1.00 0.89 0.75 0.60 1.00 0.90 0.75 0.60 1.00 0.92 0.78 0.63 1.00 0.94 0.80 0.65 1.00 1.00 0.82 0.67 1.00 1.00 0.88 0.73 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 25 23 20 17 1070 kW 1.71 1.71 1.71 1.72 1.91 1.91 1.91 1.92 2.13 2.13 2.13 2.14 2.37 2.37 2.37 2.38 2.64 2.64 2.64 2.65 2.96 2.95 2.95 2.97 Amps 6.4 6.3 6.3 6.4 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.4 9.4 10.6 10.6 10.6 10.7 12.0 12.0 12.0 12.1 Hi PR 250 252 253 258 290 291 292 297 331 332 333 338 375 376 377 382 422 423 425 429 473 474 476 480 123 124 127 132 130 131 134 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 163 MBh 29.2 29.6 30.4 31.8 28.9 29.3 30.2 31.5 28.2 28.6 29.4 30.8 26.9 27.3 28.2 29.5 25.3 25.7 26.6 27.9 23.9 24.3 25.1 26.5 S/T 1.00 0.89 0.75 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.88 0.7 AT 29 27 24 21 29 27 24 21 29 27 24 21 29 27 24 21 28 27 24 21 29 28 25 22 875 kW 1.70 1.70 1.70 1.7 1.90 1.90 1.89 1.9 2.12 2.12 2.12 2.1 2.36 2.36 2.36 2.4 2.63 2.63 2.62 2.6 2.94 2.94 2.94 3.0 Amps 6.3 6.3 6.3 6.3 7.2 7.2 7.2 7.3 8.2 8.2 8.2 8.3 9.3 9.3 9.3 9.4 10.5 10.5 10.5 10.6 12.0 12.0 12.0 12.0 Hi PR 249 250 251 256 288 289 290 295 329 330 331 336 373 374 375 380 420 421 423 427 471 472 474 478 LoPR 122 123 126 132 129 131 134 139 136 137 140 145 141 142 146 151 146 148 151 156 153 154 158 163 MBh 29.5 29.9 30.8 32.1 29.3 29.7 30.5 31.8 28.5 28.9 29.8 31.1 27.2 27.6 28.5 29.8 25.6 26.0 26.9 28.2 24.2 24.6 25.5 26.8 S/T 1.00 0.97 0.82 0.7 1.00 0.97 0.83 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 20 28 26 23 20 28 26 23 20 27 26 23 19 28 27 24 21 85 1000 kW 1.71 1.71 1.71 1.7 1.91 1.91 1.91 1.9 2.13 2.13 2.13 2.1 2.37 2.37 2.37 2.4 2.64 2.64 2.63 2.6 2.95 2.95 2.95 3.0 Amps 6.3 6.3 6.3 6.4 7.3 7.3 7.2 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.3 9.4 10.6 10.6 10.6 10.6 12.0 12.0 12.0 12.1 Hi PR 251 252 253 258 290 291 292 297 331 332 333 338 375 376 378 382 422 423 425 429 473 474 476 480 123 125 128 133 131 132 135 140 137 139 142 147 143 144 147 152 148 149 152 158 155 156 159 164 MBh 29.7 30.1 31.0 32.3 29.5 29.9 30.7 32.0 28.7 29.1 30.0 31.3 27.4 27.8 28.7 30.0 25.8 26.3 27.1 28.4 24.4 24.8 25.7 27.0 S/T 1.00 1.00 0.85 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.89 0.7 1.00 1.00 0.91 0.8 1.00 1.00 0.93 0.8 1.00 1.00 1.00 0.8 AT 27 25 22 19 27 25 22 19 27 26 23 19 27 25 22 19 27 25 22 19 28 26 23 20 1070 kW 1.72 1.71 1.71 1.7 1.92 1.91 1.91 1.9 2.14 2.14 2.13 2.1 2.38 2.38 2.37 2.4 2.64 2.64 2.64 2.7 2.96 2.96 2.95 3.0 Amps 6.4 6.4 6.4 6.4 7.3 7.3 7.3 7.3 8.3 8.3 8.3 8.3 9.4 9.4 9.4 9.4 10.6 10.6 10.6 10.7 12.1 12.1 12.0 12.1 Hi PR 252 253 254 259 291 292 294 298 332 333 335 339 376 377 379 383 423 424 426 430 474 475 477 481 124 126 129 134 132 133 136 141 138 140 143 148 1 144 145 148 153 149 150 153 159 156 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) k n z 0 m O O r- 'z G) QD IN n G) C,n N 00 O Qj N O 0 0 0 0_ 3 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 35.1 35.6 36.7 - 34.8 35.3 36.4 - 33.9 34.4 35.4 - 32.3 32.8 33.9 - 30.4 30.9 31.9 - 28.7 29.1 30.2 - S/T 0.60 0.53 0.40 0.61 0.54 0.41 0.63 0.56 0.43 0.65 0.58 0.45 0.67 0.60 0.47 1.00 0.65 0.52 AT 18 17 13 18 17 13 18 17 14 18 16 13 18 16 13 19 17 14 1050 kW 2.07 2.07 2.06 2.32 2.31 2.31 2.59 2.59 2.58 2.89 2.88 2.88 3.22 3.22 3.21 3.61 3.61 3.60 Amps 7.8 7.7 7.7 8.9 8.9 8.8 10.1 10.1 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 HIM 247 248 250 286 287 289 326 327 329 370 371 373 417 419 420 468 469 471 Lo PR 119 120 123 126 128 131 132 134 137 138 139 142 143 144 147 149 151 154 MBh 35.5 36.0 37.0 35.1 35.6 36.7 34.2 34.7 35.8 32.7 33.2 34.2 30.7 31.2 32.3 29.0 29.5 30.5 S/T 0.64 0.57 0.44 0.65 0.57 0.44 0.67 0.60 0.47 0.69 0.62 0.49 1.00 0.64 0.51 1.00 0.69 0.56 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 70 1150 kW 2.08 2.08 2.07 2.32 2.32 2.32 2.60 2.60 2.59 2.90 2.89 2.89 3.23 3.23 3.22 3.62 3.61 3.61 Amps 7.8 7.8 7.8 8.9 8.9 8.9 10.2 10.2 10.1 11.5 11.5 11.5 13.0 13.0 13.0 14.8 14.8 14.8 HiPR 248 249 251 287 288 290 328 329 331 372 373 374 419 420 422 469 470 472 Lo PR 120 122 125 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 36.3 36.7 37.8 35.9 36.4 37.5 35.0 35.5 36.6 33.5 34.0 35.0 31.5 32.0 33.1 29.8 30.3 31.3 S/T 0.68 0.61 0.48 0.69 0.61 0.48 0.71 0.64 0.51 0.73 0.66 0.52 1.00 0.68 0.55 1.00 0.73 0.60 AT 16 15 11 16 15 11 17 15 12 16 15 11 16 14 11 17 15 12 1350 kW 2.09 2.09 2.09 2.34 2.34 2.33 2.61 2.61 2.61 2.91 2.91 2.90 3.24 3.24 3.24 3.63 3.63 3.62 Amps 7.9 7.8 7.8 9.0 9.0 9.0 10.2 10.2 10.2 11.6 11.6 11.6 13.1 13.1 13.1 14.9 14.9 14.9 HiPR 251 252 254 290 291 293 331 332 333 375 376 377 422 423 425 472 473 475 Lo PR 123 124 127 130 131 134 136 138 141 142 143 146 147 148 151 153 155 158 MBh 35.1 35.6 36.7 38.3 34.8 35.3 36.4 38.0 33.9 34.4 35.5 37.1 32.4 32.8 33.9 35.5 30.4 30.9 32.0 33.6 28.7 29.2 30.2 31.8 S/T 0.73 0.65 0.52 0.39 0.73 0.66 0.53 0.39 0.76 0.68 0.55 0.42 1.00 0.70 0.57 0.44 1.00 0.72 0.59 0.46 1.00 0.77 0.64 0.51 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 14 23 21 18 15 1050 kW 2.07 2.07 2.06 2.08 2.31 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.21 3.21 3.23 3.61 3.60 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 HiPR 247 248 250 254 286 287 289 293 327 328 329 334 370 372 373 378 418 419 420 425 468 469 471 475 Lo PR 1 119 120 123 128 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 151 154 159 MBh 35.5 36.0 37.0 38.6 35.2 35.7 36.7 38.3 34.3 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.3 32.3 33.9 29.0 29.5 30.5 32.1 S/T 0.76 0.69 0.56 0.42 0.77 0.70 0.57 0.43 1.00 0.72 0.59 0.45 1.00 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.81 0.68 0.54 AT 21 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 20 17 14 75 1150 kW 2.08 2.07 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.59 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.61 3.61 3.61 3.63 Amps 7.8 7.8 7.8 7.8 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 HiPR 249 250 251 256 287 288 290 294 328 329 331 335 372 373 375 379 419 420 422 426 470 471 472 477 Lo PR 120 122 125 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 36.3 36.8 37.8 39.4 36.0 36.5 37.5 39.1 35.0 35.5 36.6 38.2 33.5 34.0 35.0 36.6 31.6 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 0.80 0.73 0.60 0.46 0.81 0.74 0.61 0.47 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 1.00 0.72 0.58 AT 20 18 15 12 20 18 15 12 20 19 15 12 20 18 15 12 20 18 15 12 21 19 16 13 1350 kW 2.09 2.09 2.09 2.10 2.34 2.33 2.33 2.35 2.61 2.61 2.61 2.62 2.91 2.91 2.90 2.92 3.24 3.24 3.23 3.25 3.63 3.63 3.62 3.64 Amps 7.8 7.8 7.8 7.9 9.0 9.0 8.9 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.6 13.1 13.1 13.1 13.2 14.9 14.9 14.9 14.9 HiPR 251 252 254 258 290 291 293 297 331 332 334 338 375 376 378 382 422 423 425 429 472 473 475 479 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 148 151 156 153 155 158 163 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) k n z o rt, 0 n O O 'z G) n n G) N O Qj al N n 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 3: MBh 35.3 35.8 36.9 38.5 35.0 35.5 36.6 38.2 34.1 34.6 35.6 37.2 32.5 33.0 34.1 35.7 30.6 31.1 32.1 33.7 28.9 29.4 30.4 32.0 S/T 0.85 0.77 0.64 0.51 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.54 1.00 0.82 0.69 0.56 1.00 0.84 0.71 0.58 1.00 1.00 0.76 0.63 AT 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1050 kW 2.07 2.07 2.06 2.08 2.32 2.31 2.31 2.33 2.59 2.59 2.58 2.60 2.89 2.88 2.88 2.90 3.22 3.22 3.21 3.23 3.61 3.61 3.60 3.62 Amps 7.7 7.7 7.7 7.8 8.9 8.9 8.8 8.9 10.1 10.1 10.1 10.2 11.5 11.5 11.5 11.5 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.8 Hi PR 248 249 250 255 286 287 289 293 327 328 330 334 371 372 374 378 418 419 421 425 469 470 471 476 Lopg 119 121 124 129 127 128 131 136 133 134 137 142 138 140 143 148 143 145 148 153 150 151 154 160 MBh 35.7 36.2 37.2 38.8 35.3 35.8 36.9 38.5 34.4 34.9 36.0 37.6 32.9 33.4 34.4 36.0 30.9 31.4 32.5 34.1 29.2 29.7 30.7 32.3 S/T 0.89 0.81 0.68 0.54 1.00 0.82 0.69 0.55 1.00 0.84 0.71 0.57 1.00 0.86 0.73 0.59 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 25 23 20 17 25 23 20 17 25 24 20 17 25 23 20 17 25 23 20 17 26 24 21 18 80 1150 kW 2.08 2.08 2.07 2.09 2.32 2.32 2.32 2.34 2.60 2.60 2.59 2.61 2.89 2.89 2.89 2.91 3.23 3.22 3.22 3.24 3.62 3.61 3.61 3.63 Amps 7.8 7.8 7.8 7.8 8.9 8.9 8.9 9.0 10.2 10.2 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 252 256 288 289 291 295 329 330 331 336 372 373 375 379 420 421 422 427 470 471 473 477 LoPR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 36.5 37.0 38.0 39.6 36.1 36.6 37.7 39.3 35.2 35.7 36.8 38.4 33.7 34.2 35.2 36.8 31.7 32.2 33.3 34.9 30.0 30.5 31.5 33.1 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.73 0.59 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 16 24 22 19 15 25 23 20 17 1350 kW 2.09 2.09 2.09 2.11 2.34 2.34 2.33 2.35 2.61 2.61 2.61 2.63 2.91 2.91 2.90 2.92 3.24 3.24 3.24 3.25 3.63 3.63 3.62 3.64 Amps 7.9 7.8 7.8 7.9 9.0 9.0 9.0 9.0 10.2 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 252 253 255 259 291 292 293 298 331 332 334 338 375 376 378 382 422 423 425 430 473 474 476 480 123 125 128 133 131 132 135 140 137 138 141 146 142 144 147 152 147 149 152 157 154 155 158 164 MBh 35.9 36.4 37.5 39.1 35.6 36.1 37.1 38.7 34.7 35.2 36.2 37.8 33.1 33.6 34.7 36.3 31.2 31.7 32.7 34.3 29.4 29.9 31.0 32.6 S/T 1.00 0.87 0.74 0.6 1.00 0.88 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.86 0.7 AT 29 28 24 21 29 27 24 21 29 28 25 21 29 27 24 21 29 27 24 21 30 28 25 22 1050 kW 2.07 2.07 2.07 2.1 2.32 2.32 2.31 2.3 2.59 2.59 2.59 2.6 2.89 2.89 2.88 2.9 3.22 3.22 3.22 3.2 3.61 3.61 3.61 3.6 Amps 7.8 7.8 7.7 7.8 8.9 8.9 8.9 9.0 10.2 10.1 10.1 10.2 11.5 11.5 11.5 11.6 13.0 13.0 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 249 250 251 256 288 289 290 295 328 329 331 335 372 373 375 379 419 420 422 426 470 471 473 477 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 144 150 145 147 150 155 152 153 156 161 MBh 36.2 36.7 37.8 39.4 35.9 36.4 37.5 39.1 35.0 35.5 36.6 38.2 33.4 33.9 35.0 36.6 31.5 32.0 33.1 34.7 29.8 30.3 31.3 32.9 S/T 1.00 0.91 0.78 0.6 1.00 0.92 0.78 0.6 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 20 28 27 24 20 28 27 23 20 29 28 24 21 85 1150 kW 2.08 2.08 2.08 2.1 2.33 2.33 2.32 2.3 2.60 2.60 2.60 2.6 2.90 2.90 2.89 2.9 3.23 3.23 3.23 3.2 3.62 3.62 3.61 3.6 Amps 7.8 7.8 7.8 7.9 8.9 8.9 8.9 9.0 10.2 10.2 10.2 10.2 11.6 11.5 11.5 11.6 13.1 13.1 13.0 13.1 14.8 14.8 14.8 14.9 Hi PR 250 251 253 257 289 290 292 296 330 331 332 337 373 375 376 381 421 422 424 428 471 472 474 478 122 124 127 132 130 131 134 139 136 137 140 145 141 143 146 151 146 148 151 156 153 154 157 163 MBh 37.0 37.5 38.6 40.2 36.7 37.2 38.3 39.9 35.8 36.3 37.4 39.0 34.2 34.7 35.8 37.4 32.3 32.8 33.9 35.5 30.6 31.1 32.1 33.7 S/T 1.00 0.95 0.82 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.8 1.00 1.00 1.00 0.8 AT 27 26 22 19 27 26 22 19 28 26 23 19 27 26 22 19 27 25 22 19 28 26 23 20 1350 kW 2.10 2.10 2.09 2.1 2.34 2.34 2.34 2.4 2.62 2.62 2.61 2.6 2.91 2.91 2.91 2.9 3.25 3.24 3.24 3.3 3.64 3.63 3.63 3.6 Amps 7.9 7.9 7.8 7.9 9.0 9.0 9.0 9.1 10.3 10.2 10.2 10.3 11.6 11.6 11.6 11.7 13.1 13.1 13.1 13.2 14.9 14.9 14.9 15.0 Hi PR 253 254 256 260 292 293 295 299 333 334 335 340 376 377 379 383 424 425 426 431 474 475 477 481 125 127 130 135 132 134 137 142 139 140 143 148 1 144 145 148 154 149 151 154 159 156 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) k n n Gi N O 0) N O V LO Q) W G) n C O O n O z y ao 0 0 0- 3 v 0 3 0 0 3 Outdoor Ambient Temperature 652F 752F 852E I 952F 1052F 1152F Entering Indoor Wet Bulb Temperature 3: MBh 40.9 41.4 42.6 - 40.5 41.1 42.3 - 39.4 40.0 41.2 - 37.6 38.2 39.4 - 35.4 35.9 37.2 - 33.3 33.9 35.1 - S/T 0.63 0.55 0.42 0.63 0.56 0.42 0.66 0.58 0.45 0.68 0.60 0.47 1.00 0.63 0.49 1.00 0.68 0.54 AT 19 17 14 19 17 14 19 17 14 19 17 14 18 17 13 19 18 14 1225 kW 2.42 2.42 2.41 2.70 2.70 2.70 3.02 3.01 3.01 3.36 3.35 3.35 3.74 3.73 3.73 4.18 4.18 4.17 Amps 9.0 9.0 9.0 10.3 10.3 10.3 11.7 11.7 11.7 13.3 13.3 13.3 15.0 15.0 15.0 17.1 17.1 17.0 HiPR 240 241 243 278 279 281 318 319 321 361 362 363 407 408 409 456 457 458 Lo PR 120 121 124 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 41.2 41.8 43.0 40.9 41.4 42.7 39.8 40.4 41.6 38.0 38.5 39.8 35.7 36.3 37.5 33.7 34.3 35.5 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 0.72 0.64 0.51 1.00 0.66 0.53 1.00 0.71 0.58 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1340 kW 2.43 2.43 2.42 2.71 2.71 2.71 3.03 3.02 3.02 3.37 3.36 3.36 3.75 3.74 3.74 4.19 4.19 4.18 Amps 9.1 9.1 9.0 10.3 10.3 10.3 11.8 11.8 11.8 13.3 13.3 13.3 15.1 15.1 15.0 17.1 17.1 17.1 HiPR 242 243 245 280 281 282 319 320 322 362 363 365 408 409 411 457 458 460 Lo PR 121 123 126 128 130 133 135 136 139 140 142 145 145 147 150 152 154 157 MBh 42.2 42.7 44.0 41.8 42.4 43.6 40.7 41.3 42.5 38.9 39.5 40.7 36.7 37.3 38.5 34.6 35.2 36.4 S/T 0.71 0.63 0.50 0.71 0.64 0.50 0.74 0.66 0.53 0.76 0.68 0.55 1.00 0.70 0.57 1.00 0.76 0.62 AT 17 15 12 17 15 12 17 15 12 17 15 12 16 15 11 18 16 13 1575 kW 2.45 2.45 2.44 2.73 2.73 2.72 3.04 3.04 3.04 3.38 3.38 3.38 3.76 3.76 3.76 4.21 4.21 4.20 Amps 9.1 9.1 9.1 10.4 10.4 10.4 11.9 11.9 11.8 13.4 13.4 13.4 15.2 15.1 15.1 17.2 17.2 17.2 HiPR 245 246 247 282 283 285 322 323 325 365 366 368 411 412 414 460 461 463 Lo PR 1 124 125 128 131 133 136 138 139 142 143 144 148 148 150 153 155 156 159 MBh 40.9 41.5 42.7 44.5 40.5 41.1 42.3 44.2 39.4 40.0 41.2 43.1 37.6 38.2 39.4 41.3 35.4 36.0 37.2 39.0 33.3 33.9 35.1 37.0 S/T 0.76 0.68 0.55 0.40 0.76 0.69 0.55 0.41 1.00 0.71 0.58 0.43 1.00 0.73 0.60 0.45 1.00 0.75 0.62 0.48 1.00 0.81 0.67 0.53 AT 23 21 18 14 23 21 17 14 23 21 18 14 22 21 17 14 22 21 17 14 23 22 18 15 1225 kW 2.42 2.42 2.41 2.43 2.70 2.70 2.69 2.72 3.01 3.01 3.01 3.03 3.35 3.35 3.35 3.37 3.73 3.73 3.73 3.75 4.18 4.18 4.17 4.19 Amps 9.0 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.7 11.7 11.7 11.8 13.3 13.3 13.3 13.4 15.0 15.0 15.0 1S.1 17.1 17.1 17.0 17.1 HiPR 241 242 243 248 278 280 281 285 318 319 321 325 361 362 364 368 407 408 410 414 456 457 459 463 Lo PR 120 121 124 130 127 129 132 137 134 135 138 143 139 140 144 149 144 146 149 154 151 152 155 160 MBh 41.3 41.8 43.0 44.9 40.9 41.5 42.7 44.5 39.8 40.4 41.6 43.5 38.0 38.6 39.8 41.6 35.8 36.3 37.6 39.4 33.7 34.3 35.5 37.4 S/T 0.80 0.72 0.58 0.44 0.80 0.73 0.59 0.45 1.00 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.84 0.71 0.57 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 1340 kW 2.43 2.43 2.42 2.44 2.71 2.71 2.70 2.72 3.02 3.02 3.02 3.04 3.36 3.36 3.36 3.38 3.74 3.74 3.74 3.76 4.19 4.19 4.18 4.20 Amps 9.1 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.8 11.8 11.7 11.8 13.3 13.3 13.3 13.4 15.1 15.1 15.0 15.1 17.1 17.1 17.1 17.2 HiPR 242 243 245 249 280 281 283 287 320 321 322 326 362 363 365 369 408 409 411 415 457 458 460 464 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 142 145 150 145 147 150 155 152 154 157 162 MBh 42.2 42.8 44.0 45.8 41.8 42.4 43.6 45.5 40.8 41.3 42.6 44.4 38.9 39.5 40.7 42.6 36.7 37.3 38.5 40.3 34.7 35.2 36.5 38.3 S/T 0.84 0.76 0.63 0.48 0.84 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.81 0.68 0.53 1.00 0.83 0.70 0.55 1.00 1.00 0.75 0.61 AT 21 19 16 12 21 19 16 12 21 19 16 12 21 19 16 12 20 19 15 12 21 20 16 13 1575 kW 2.45 2.44 2.44 2.46 2.73 2.72 2.72 2.74 3.04 3.04 3.03 3.06 3.38 3.38 3.37 3.40 3.76 3.76 3.75 3.78 4.21 4.20 4.20 4.22 Amps 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.5 11.9 11.8 11.8 11.9 13.4 13.4 13.4 13.5 15.1 15.1 15.1 15.2 17.2 17.2 17.2 17.3 HiPR 245 246 248 252 283 284 285 290 322 323 325 329 365 366 368 372 411 412 414 418 460 461 463 467 Lo PR 124 125 129 134 131 133 136 141 138 139 142 147 143 144 148 153 148 150 153 158 155 156 159 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n C) N O ti H N n c N O 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE Di MBh 41.1 41.7 42.9 44.7 40.7 41.3 42.5 44.4 39.7 40.2 41.5 43.3 37.8 38.4 39.6 41.5 35.6 36.2 37.4 39.2 33.6 34.1 35.3 37.2 S/T 0.88 0.81 0.67 0.53 1.00 0.81 0.68 0.53 1.00 0.84 0.70 0.56 1.00 0.86 0.72 0.58 1.00 1.00 0.74 0.60 1.00 1.00 0.80 0.65 AT 26 25 21 18 26 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 26 22 19 1225 kW 2.42 2.42 2.41 2.44 2.70 2.70 2.70 2.72 3.02 3.01 3.01 3.03 3.36 3.35 3.35 3.37 3.74 3.73 3.73 3.75 4.18 4.18 4.17 4.20 Amps 9.0 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.7 11.7 11.7 11.8 13.3 13.3 13.3 13.4 15.0 15.0 15.0 15.1 17.1 17.1 17.0 17.1 Hi PR 241 242 244 248 279 280 282 286 319 320 321 325 361 362 364 368 407 408 410 414 456 457 459 463 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 140 141 144 149 145 146 149 154 151 153 156 161 MBh 41.5 42.0 43.3 45.1 41.1 41.7 42.9 44.7 40.0 40.6 41.8 43.7 38.2 38.8 40.0 41.9 36.0 36.5 37.8 39.6 33.9 34.5 35.7 37.6 S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.78 0.64 1.00 1.00 0.83 0.69 AT 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 25 24 20 17 27 25 22 18 80 1340 kW 2.43 2.43 2.42 2.44 2.71 2.71 2.70 2.73 3.03 3.02 3.02 3.04 3.37 3.36 3.36 3.38 3.75 3.74 3.74 3.76 4.19 4.19 4.18 4.21 Amps 9.1 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.3 13.3 13.3 13.4 15.1 15.1 15.0 15.1 17.1 17.1 17.1 17.2 Hi PR 242 244 245 249 280 281 283 287 320 321 323 327 363 364 365 370 409 410 411 416 458 459 461 465 Lo PR 122 123 126 131 129 130 134 139 135 137 140 145 141 142 145 150 146 147 151 156 153 154 157 162 MBh 42.4 43.0 44.2 46.0 42.0 42.6 43.8 45.7 41.0 41.5 42.8 44.6 39.1 39.7 40.9 42.8 36.9 37.5 38.7 40.6 34.9 35.4 36.7 38.5 S/T 1.00 0.89 0.75 0.61 1.00 0.89 0.76 0.61 1.00 0.92 0.78 0.64 1.00 0.94 0.80 0.66 1.00 1.00 0.82 0.68 1.00 1.00 0.87 0.73 AT 25 23 19 16 24 23 19 16 25 23 20 16 24 23 19 16 24 22 19 16 25 24 20 17 1575 kW 2.45 2.45 2.44 2.46 2.73 2.73 2.72 2.74 3.04 3.04 3.04 3.06 3.38 3.38 3.38 3.40 3.76 3.76 3.76 3.78 4.21 4.21 4.20 4.22 Amps 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.5 11.9 11.9 11.8 11.9 13.4 13.4 13.4 13.5 15.2 15.1 15.1 15.2 17.2 17.2 17.2 17.3 Hi PR 245 246 248 252 283 284 286 290 323 324 325 330 365 366 368 372 411 412 414 418 461 462 463 467 Lo PR 1 125 126 129 134 132 133 136 141 138 140 143 148 144 145 148 153 149 150 153 158 155 157 160 165 MBh 41.8 42.3 43.6 45.4 41.4 42.0 43.2 45.1 40.3 40.9 42.1 44.0 38.5 39.1 40.3 42.2 36.3 36.9 38.1 39.9 34.2 34.8 36.0 37.9 S/T 1.00 0.91 0.77 0.6 1.00 0.91 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.90 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 22 30 28 25 21 30 28 25 21 31 29 26 22 1225 kW 2.43 2.42 2.42 2.4 2.71 2.71 2.70 2.7 3.02 3.02 3.01 3.0 3.36 3.36 3.35 3.4 3.74 3.74 3.73 3.8 4.19 4.18 4.18 4.2 Amps 9.0 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.8 11.8 11.7 11.8 13.3 13.3 13.3 13.4 1S.1 1S.0 1S.0 15.1 17.1 17.1 17.1 17.2 Hi PR 242 243 245 249 280 281 283 287 320 321 322 327 362 363 365 369 408 409 411 415 458 459 460 464 Lo PR 122 124 127 132 130 131 134 139 136 137 140 146 141 143 146 151 147 148 151 156 153 155 158 163 MBh 42.2 42.7 43.9 45.8 41.8 42.4 43.6 45.4 40.7 41.3 42.5 44.4 38.9 39.5 40.7 42.5 36.7 37.2 38.5 40.3 34.6 35.2 36.4 38.3 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1340 kW 2.44 2.43 2.43 2.5 2.72 2.72 2.71 2.7 3.03 3.03 3.02 3.0 3.37 3.37 3.36 3.4 3.75 3.75 3.74 3.8 4.20 4.19 4.19 4.2 Amps 9.1 9.1 9.1 9.2 10.4 10.4 10.3 10.4 11.8 11.8 11.8 11.9 13.4 13.4 13.3 13.4 15.1 15.1 15.1 15.2 17.1 17.1 17.1 17.2 Hi PR 244 245 246 251 281 282 284 288 321 322 324 328 364 365 366 371 410 411 413 417 459 460 462 466 Lo PR 124 125 128 133 131 132 135 140 137 139 142 147 143 144 147 152 148 149 152 157 154 156 159 164 MBh 43.1 43.7 44.9 46.7 42.7 43.3 44.5 46.4 41.7 42.2 43.4 45.3 39.8 40.4 41.6 43.5 37.6 38.2 39.4 41.2 35.6 36.1 37.3 39.2 S/T 1.00 0.99 0.85 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 1.00 0.8 AT 28 26 23 20 28 26 23 19 28 26 23 20 28 26 23 19 28 26 23 19 29 27 24 20 1575 kW 2.45 2.45 2.45 2.5 2.73 2.73 2.73 2.7 3.05 3.05 3.04 3.1 3.39 3.39 3.38 3.4 3.77 3.77 3.76 3.8 4.21 4.21 4.21 4.2 Amps 9.2 9.2 9.1 9.2 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.4 13.4 13.4 13.5 15.2 15.2 15.1 15.2 17.2 17.2 17.2 17.3 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 369 373 413 414 415 419 462 463 464 469 Lo PR 126 128 131 136 134 135 138 143 140 141 144 150 145 147 150 155 151 152 155 160 157 159 162 167 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor +fan) k n z 0 m O O 'z G1 Q) IN n V LO 0 0 0 0_ 3 v 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.7 47.3 48.7 - 46.3 46.9 48.3 - 45.1 45.7 47.1 - 43.0 43.6 45.0 - 40.4 41.1 42.5 - 38.1 38.8 40.2 - S/T 0.63 0.56 0.43 0.64 0.56 0.43 0.66 0.59 0.46 0.68 0.61 0.48 1.00 0.63 0.50 1.00 0.68 0.55 AT 19 17 14 19 17 13 19 17 14 19 17 13 18 17 13 19 18 14 1400 kW 2.73 2.73 2.73 3.06 3.06 3.05 3.43 3.43 3.42 3.82 3.82 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.3 17.3 17.3 19.7 19.7 19.7 HiPR 243 244 246 282 283 284 322 323 324 365 366 367 411 412 414 461 462 463 Lo PR 120 121 124 127 129 132 134 135 138 139 140 143 144 146 149 151 152 155 MBh 46.9 47.6 48.9 46.5 47.1 48.5 45.3 45.9 47.3 43.2 43.9 45.2 40.7 41.3 42.7 38.3 39.0 40.4 S/T 0.65 0.57 0.44 0.66 0.58 0.45 0.68 0.61 0.47 0.70 0.62 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 18 17 13 18 16 13 19 17 13 18 16 13 18 16 13 19 17 14 70 1460 kW 2.74 2.74 2.73 3.07 3.06 3.06 3.43 3.43 3.43 3.83 3.83 3.82 4.27 4.27 4.26 4.79 4.79 4.78 Amps 10.3 10.3 10.3 11.8 11.8 11.8 13.5 13.5 13.5 15.3 15.3 15.3 17.4 17.4 17.3 19.7 19.7 19.7 HiPR 244 245 247 282 283 285 322 323 325 365 366 368 412 413 414 461 462 464 Lo PR 121 122 125 128 129 132 134 136 139 139 141 144 145 146 149 151 153 156 MBh 47.4 48.1 49.5 47.0 47.7 49.1 45.8 46.5 47.9 43.7 44.4 45.8 41.2 41.9 43.2 38.9 39.5 40.9 S/T 0.68 0.60 0.47 0.68 0.61 0.48 0.71 0.63 0.50 0.73 0.65 0.52 1.00 0.67 0.54 1.00 0.72 0.59 AT 18 16 12 18 16 12 18 16 13 18 16 12 17 15 12 18 17 13 1600 kW 2.75 2.75 2.74 3.08 3.08 3.07 3.44 3.44 3.44 3.84 3.84 3.83 4.28 4.28 4.28 4.80 4.80 4.80 Amps 10.4 10.4 10.4 11.9 11.9 11.9 13.6 13.6 13.5 15.4 15.4 15.4 17.4 17.4 17.4 19.8 19.8 19.8 HiPR 246 247 248 284 285 286 324 325 326 367 368 370 413 414 416 463 464 466 Lo PR 1 122 123 127 129 131 134 136 137 140 141 142 145 146 148 151 153 154 157 MBh 46.7 47.4 48.8 50.9 46.3 47.0 48.3 50.4 45.1 45.7 47.1 49.2 43.0 43.7 45.0 47.2 40.5 41.1 42.5 44.6 38.1 38.8 40.2 42.3 S/T 0.76 0.68 0.55 0.41 0.76 0.69 0.56 0.42 1.00 0.72 0.58 0.44 1.00 0.73 0.60 0.46 1.00 0.76 0.62 0.48 1.00 0.81 0.67 0.53 AT 23 21 17 14 23 21 17 14 23 21 18 14 23 21 17 14 22 20 17 14 23 22 18 15 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.42 3.42 3.44 3.82 3.82 3.81 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.S 13.5 13.6 15.3 15.3 15.3 1S.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 HiPR 244 245 246 251 282 283 284 289 322 323 324 329 365 366 368 372 411 412 414 418 461 462 464 468 Lo PR 1 120 121 124 130 127 129 132 137 134 135 138 143 139 140 143 148 144 146 149 154 151 152 155 160 MBh 46.9 47.6 49.0 51.1 46.5 47.2 48.5 50.7 45.3 46.0 47.3 49.5 43.2 43.9 45.3 47.4 40.7 41.3 42.7 44.8 38.4 39.0 40.4 42.5 S/T 0.77 0.70 0.57 0.43 0.78 0.71 0.57 0.44 1.00 0.73 0.60 0.46 1.00 0.75 0.62 0.48 1.00 0.77 0.64 O.SO 1.00 0.82 0.69 0.5S AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 75 1460 kW 2.74 2.73 2.73 2.75 3.06 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.84 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.3 17.3 17.4 19.7 19.7 19.7 19.8 HiPR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 415 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.5 48.1 49.5 51.6 47.1 47.7 49.1 51.2 45.9 46.5 47.9 50.0 43.8 44.4 45.8 47.9 41.2 41.9 43.3 45.4 38.9 39.6 40.9 43.1 S/T 0.80 0.73 0.60 0.46 0.81 0.73 0.60 0.46 1.00 0.76 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.80 0.67 0.53 1.00 0.85 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1600 kW 2.75 2.74 2.74 2.76 3.08 3.07 3.07 3.09 3.44 3.44 3.43 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.27 4.30 4.80 4.80 4.79 4.82 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.6 15.4 15.4 15.3 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 HIM 246 247 248 253 284 285 287 291 324 325 327 331 367 368 370 374 413 414 416 420 463 464 466 470 Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 151 146 148 151 156 153 154 157 162 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (TVA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n C) to N O DD H 0 0 0 Q v 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F D: ENTERING INDOOR WET BULB TEMPERATURE MBh 47.0 47.6 49.0 51.1 46.5 47.2 48.6 50.7 45.3 46.0 47.4 49.5 43.3 43.9 45.3 47.4 40.7 41.4 42.7 44.9 38.4 39.0 40.4 42.5 S/T 0.88 0.81 0.67 0.54 1.00 0.81 0.68 0.54 1.00 0.84 0.71 0.57 1.00 0.86 0.72 0.58 1.00 1.00 0.75 0.61 1.00 1.00 0.80 0.66 AT 27 25 21 18 27 25 21 18 27 25 22 18 26 25 21 18 26 24 21 18 27 26 22 19 1400 kW 2.73 2.73 2.72 2.75 3.06 3.06 3.05 3.08 3.43 3.43 3.42 3.44 3.82 3.82 3.82 3.84 4.27 4.26 4.26 4.28 4.79 4.78 4.78 4.80 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.3 17.3 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 244 245 247 251 282 283 285 289 322 323 325 329 365 366 368 372 412 413 414 419 461 462 464 468 Lo PR 121 122 125 130 128 129 132 137 134 136 139 144 139 141 144 149 145 146 149 154 151 153 156 161 MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.5 46.2 47.6 49.7 43.5 44.1 45.5 47.6 40.9 41.6 43.0 45.1 38.6 39.3 40.6 42.8 S/T 0.90 0.82 0.69 0.55 1.00 0.83 0.70 0.56 1.00 0.85 0.72 0.58 1.00 0.87 0.74 0.60 1.00 1.00 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 80 1460 kW 2.74 2.74 2.73 2.76 3.07 3.06 3.06 3.08 3.43 3.43 3.42 3.45 3.83 3.83 3.82 3.85 4.27 4.27 4.26 4.29 4.79 4.79 4.78 4.81 Amps 10.3 10.3 10.3 10.4 11.8 11.8 11.8 11.9 13.5 13.5 13.5 13.6 15.3 15.3 15.3 15.4 17.4 17.4 17.3 17.4 19.7 19.7 19.7 19.8 Hi PR 245 246 247 252 283 284 286 290 323 324 326 330 366 367 369 373 412 413 415 419 462 463 465 469 Lo PR 121 123 126 131 128 130 133 138 135 136 139 144 140 141 145 150 145 147 150 155 152 153 156 161 MBh 47.7 48.4 49.8 51.9 47.3 48.0 49.3 51.4 46.1 46.7 48.1 50.2 44.0 44.7 46.0 48.2 41.5 42.1 43.5 45.6 39.1 39.8 41.2 43.3 S/T 1.00 0.85 0.72 0.58 1.00 0.86 0.72 0.58 1.00 0.88 0.75 0.61 1.00 0.90 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.84 0.70 AT 26 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 25 21 18 1600 kW 2.75 2.75 2.74 2.77 3.08 3.07 3.07 3.09 3.44 3.44 3.44 3.46 3.84 3.84 3.83 3.86 4.28 4.28 4.28 4.30 4.80 4.80 4.80 4.82 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.5 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 414 415 417 421 463 464 466 470 Lo PR 1 123 124 127 132 130 131 134 139 136 138 141 146 141 143 146 151 147 148 151 156 153 155 158 163 1400 MBh S/T AT kW Amps Hi PR Lo PR 47.7 1.00 30 2.74 10.3 245 122 48.4 0.91 28 2.74 10.3 246 124 49.8 0.77 25 2.73 10.3 248 127 51.9 0.6 21 2.8 10.4 252 132 47.3 1.00 30 3.07 11.9 283 130 48.0 0.91 28 3.06 11.8 284 131 49.4 0.78 25 3.06 11.8 286 134 51.5 0.6 21 3.1 11.9 290 139 46.1 1.00 30 3.43 13.5 323 136 46.8 1.00 28 3.43 13.5 324 137 48.1 0.80 25 3.43 13.5 326 140 50.3 0.7 22 3.5 13.6 330 145 44.0 1.00 30 3.83 15.3 366 141 44.7 1.00 28 3.83 15.3 367 143 46.1 0.82 25 3.82 15.3 369 146 48.2 0.7 21 3.8 15.4 373 151 41.5 1.00 30 4.27 17.4 413 146 42.1 1.00 28 4.27 17.4 414 148 43.5 0.84 25 4.27 17.3 416 151 45.6 0.7 21 4.3 17.4 420 156 39.2 1.00 31 4.79 19.8 462 153 39.8 1.00 29 4.79 19.7 463 155 41.2 0.89 26 4.79 19.7 465 158 43.3 0.8 22 4.8 19.8 469 163 MBh 47.9 48.6 50.0 52.1 47.5 48.2 49.6 51.7 46.3 47.0 48.4 50.5 44.2 44.9 46.3 48.4 41.7 42.4 43.7 45.9 39.4 40.0 41.4 43.5 S/T 1.00 0.92 0.79 0.7 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.91 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 29 28 24 21 31 29 25 22 85 1460 kW 2.74 2.74 2.74 2.8 3.07 3.07 3.06 3.1 3.44 3.44 3.43 3.5 3.84 3.83 3.83 3.9 4.28 4.28 4.27 4.3 4.80 4.80 4.79 4.8 Amps 10.4 10.4 10.3 10.5 11.9 11.9 11.8 12.0 13.6 13.5 13.5 13.6 15.4 15.4 15.3 15.4 17.4 17.4 17.4 17.5 19.8 19.8 19.7 19.9 Hi PR 246 247 249 253 284 285 287 291 324 325 327 331 367 368 370 374 413 415 416 420 463 464 466 470 Lo PR 123 124 127 132 130 132 135 140 136 138 141 146 142 143 146 151 147 149 152 157 154 155 158 163 MBh 48.5 49.1 50.5 52.6 48.1 48.7 50.1 52.2 46.9 47.5 48.9 51.0 44.8 45.4 46.8 48.9 42.2 42.9 44.3 46.4 39.9 40.6 42.0 44.1 S/T 1.00 0.95 0.82 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1600 kW 2.76 2.75 2.75 2.8 3.08 3.08 3.08 3.1 3.45 3.45 3.44 3.5 3.85 3.84 3.84 3.9 4.29 4.29 4.28 4.3 4.81 4.81 4.80 4.8 Amps 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 17.4 17.4 17.4 17.5 19.8 19.8 19.8 19.9 Hi PR 247 248 250 254 285 287 288 292 325 327 328 332 369 370 371 376 415 416 418 422 465 466 467 472 Lo PR 124 126 129 134 132 133 136 141 138 139 142 147 143 145 148 153 149 150 153 158 155 157 160 165 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor +fan) k n n Gi Ln N OJ O 00 N O V LO 00 n C O O O z .H 0 0 0 0_ 3 of 0 3 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 56.4 57.2 58.8 - 55.9 56.7 58.3 - 54.4 55.2 56.9 - 51.9 52.7 54.4 - 48.8 49.6 51.3 - 46.0 46.8 48.5 - S/T 0.65 0.57 0.43 0.65 0.58 0.44 0.68 0.60 0.47 0.70 0.62 0.49 0.72 0.64 0.51 1.00 0.69 0.56 AT 18 17 13 18 17 13 19 17 14 18 17 13 18 16 13 19 17 14 1750 kW 3.41 3.41 3.40 3.83 3.83 3.82 4.31 4.31 4.30 4.82 4.82 4.81 5.40 5.40 5.39 6.07 6.07 6.06 Amps 12.9 12.9 12.9 14.9 14.9 14.8 17.1 17.0 17.0 19.4 19.4 19.4 22.0 22.0 22.0 25.1 25.1 25.1 HiPR 258 259 261 298 299 301 340 342 343 386 387 389 435 436 438 488 489 491 Lo PR 116 117 120 123 124 127 129 130 133 134 135 138 139 141 143 145 147 150 MBh 56.7 57.5 59.2 56.2 57.0 58.7 54.7 55.5 57.2 52.2 53.0 54.7 49.1 49.9 51.6 46.3 47.1 48.8 S/T 0.67 0.59 0.45 0.67 0.60 0.46 0.70 0.62 0.49 0.72 0.64 0.51 0.74 0.66 0.53 1.00 0.71 0.58 AT 18 16 13 18 16 13 18 16 13 18 16 13 18 16 13 19 17 14 70 1840 kW 3.42 3.41 3.41 3.84 3.84 3.83 4.32 4.31 4.31 4.83 4.83 4.82 5.41 5.40 5.40 6.08 6.08 6.07 Amps 13.0 12.9 12.9 14.9 14.9 14.9 17.1 17.1 17.0 19.4 19.4 19.4 22.1 22.1 22.0 25.2 25.1 25.1 HiPR 258 260 261 299 300 302 341 342 344 387 388 390 436 437 439 489 490 492 Lo PR 116 118 121 123 125 128 130 131 134 135 136 139 140 141 144 146 148 150 MBh 57.0 57.8 59.4 56.5 57.3 58.9 55.0 55.8 57.5 52.5 53.3 55.0 49.4 50.2 51.9 46.6 47.4 49.1 S/T 0.68 0.60 0.47 0.69 0.61 0.48 0.71 0.64 0.50 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.73 0.59 AT 18 16 13 18 16 13 18 16 13 18 16 13 17 16 12 18 17 13 1920 kW 3.42 3.42 3.41 3.85 3.85 3.84 4.32 4.32 4.31 4.84 4.84 4.83 5.41 5.41 5.40 6.09 6.08 6.08 Amps 13.0 13.0 12.9 14.9 14.9 14.9 17.1 17.1 17.1 19.5 19.5 19.4 22.1 22.1 22.1 25.2 25.2 25.1 HIM 259 260 262 300 301 303 342 343 345 388 389 391 437 438 440 489 490 492 Lo PR 1 117 118 121 124 125 128 130 132 134 135 137 140 140 142 145 147 148 151 MBh 56.4 57.2 58.9 61.4 55.9 56.7 58.4 60.9 54.5 55.2 56.9 59.5 51.9 52.7 54.4 57.0 48.9 49.7 51.3 53.9 46.1 46.9 48.5 51.1 S/T 0.78 0.70 0.56 0.42 0.78 0.71 0.57 0.43 0.81 0.73 0.60 0.45 1.00 0.75 0.61 0.47 1.00 0.77 0.64 0.49 1.00 0.82 0.69 0.55 AT 22 20 17 14 22 20 17 14 22 21 17 14 22 20 17 14 22 20 17 13 23 21 18 15 1750 kW 3.41 3.40 3.39 3.43 3.83 3.83 3.82 3.85 4.31 4.30 4.30 4.33 4.82 4.82 4.81 4.84 5.40 5.39 5.39 5.42 6.07 6.07 6.06 6.09 Amps 12.9 12.9 12.9 13.0 14.9 14.8 14.8 15.0 17.0 17.0 17.0 17.1 19.4 19.4 19.3 19.5 22.0 22.0 22.0 22.1 25.1 25.1 25.1 25.2 HiPR 258 259 261 265 298 299 301 306 341 342 344 348 386 387 389 394 436 437 438 443 488 489 491 495 Lo PR 1 116 117 120 125 123 124 127 132 129 130 133 138 134 135 138 143 139 141 143 148 145 147 150 155 MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.8 55.6 57.2 59.8 52.2 53.0 54.7 57.3 49.2 50.0 51.6 54.2 46.4 47.2 48.8 51.4 S/T 0.80 0.72 0.58 0.44 0.80 0.73 0.59 0.45 0.83 0.75 0.62 0.47 1.00 0.77 0.63 0.49 1.00 0.79 0.66 0.51 1.00 0.84 0.71 0.57 AT 22 20 17 13 22 20 17 13 22 20 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 1840 kW 3.41 3.41 3.40 3.44 3.84 3.84 3.83 3.86 4.31 4.31 4.30 4.34 4.83 4.83 4.82 4.85 5.40 5.40 5.39 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.0 22.0 22.2 25.1 25.1 25.1 25.2 HiPR 259 260 262 266 299 300 302 307 342 343 344 349 387 388 390 395 436 437 439 444 489 490 492 496 Lo PR 116 118 121 126 123 125 128 133 130 131 134 139 135 136 139 144 140 141 144 149 146 148 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.4 49.1 51.7 S/T 0.81 0.73 0.60 0.46 0.82 0.74 0.60 0.46 0.84 0.77 0.63 0.49 1.00 0.78 0.65 0.51 1.00 0.81 0.67 0.53 1.00 0.86 0.72 0.58 AT 22 20 16 13 21 20 16 13 22 20 17 13 21 20 16 13 21 19 16 13 22 21 17 14 1920 kW 3.42 3.42 3.41 3.44 3.85 3.84 3.84 3.87 4.32 4.32 4.31 4.34 4.84 4.83 4.83 4.86 5.41 5.41 5.40 5.43 6.09 6.08 6.07 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.4 19.4 19.6 22.1 22.1 22.0 22.2 25.2 25.2 25.1 25.3 HiPR 259 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 444 490 491 492 497 Lo PR 117 119 121 126 124 125 128 133 130 132 135 139 135 137 140 145 140 142 145 150 147 148 151 156 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects ACCA (NA) Rating Conditions. kW = Total system power Amps = Outdoor unit amps (compressor + fan) x n C) Ln N QJ O O H 0 0 0 Q 3 dip n 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE Di MBh 56.7 57.5 59.2 61.7 56.2 57.0 58.7 61.2 54.7 55.5 57.2 59.8 52.2 53.0 54.7 57.2 49.2 50.0 51.6 54.2 46.4 47.1 48.8 51.4 S/T 0.90 0.83 0.69 0.55 1.00 0.83 0.70 0.55 1.00 0.86 0.72 0.58 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 1.00 0.81 0.67 AT 26 24 21 18 26 24 21 18 26 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1750 kW 3.41 3.40 3.40 3.43 3.83 3.83 3.82 3.86 4.31 4.31 4.30 4.33 4.82 4.82 4.81 4.85 5.40 5.39 5.39 5.42 6.07 6.07 6.06 6.09 Amps 12.9 12.9 12.9 13.0 14.9 14.9 14.8 15.0 17.0 17.0 17.0 17.1 19.4 19.4 19.4 19.5 22.0 22.0 22.0 22.1 25.1 25.1 25.1 25.2 Hi PR 258 259 261 266 299 300 302 306 341 342 344 349 387 388 390 394 436 437 439 443 488 490 491 496 Lo PR 116 118 121 126 123 125 128 132 129 131 134 139 135 136 139 144 140 141 144 149 146 147 150 155 MBh 57.0 57.8 59.5 62.0 56.5 57.3 59.0 61.5 55.1 55.8 57.5 60.1 52.5 53.3 55.0 57.6 49.5 50.3 51.9 54.5 46.7 47.5 49.1 51.7 S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 0.92 0.78 0.64 1.00 1.00 0.83 0.69 AT 26 24 21 17 26 24 21 17 26 24 21 18 26 24 21 17 25 24 20 17 27 25 22 18 80 1840 kW 3.42 3.41 3.41 3.44 3.84 3.84 3.83 3.86 4.32 4.31 4.31 4.34 4.83 4.83 4.82 4.85 5.41 5.40 5.40 5.43 6.08 6.08 6.07 6.10 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 259 260 262 267 300 301 303 307 342 343 345 349 388 389 391 395 437 438 440 444 489 490 492 497 Lo PR 117 118 121 126 124 125 128 133 130 131 134 139 135 137 140 144 140 142 145 150 147 148 151 156 MBh 57.3 58.1 59.8 62.3 56.8 57.6 59.3 61.8 55.3 56.1 57.8 60.4 52.8 53.6 55.3 57.8 49.8 50.5 52.2 54.8 46.9 47.7 49.4 52.0 S/T 0.94 0.86 0.72 0.58 1.00 0.87 0.73 0.59 1.00 0.89 0.76 0.61 1.00 0.91 0.77 0.63 1.00 0.93 0.80 0.65 1.00 1.00 0.85 0.71 AT 25 24 20 17 25 24 20 17 26 24 21 17 25 24 20 17 25 23 20 17 26 24 21 18 1920 kW 3.42 3.42 3.41 3.44 3.85 3.85 3.84 3.87 4.32 4.32 4.31 4.35 4.84 4.84 4.83 4.86 5.41 5.41 5.40 5.44 6.09 6.08 6.08 6.11 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 2S.3 Hi PR 260 261 263 267 300 301 303 308 343 344 346 350 388 389 391 396 438 439 440 445 490 491 493 497 Lo PR 1 118 119 122 127 1 125 126 129 134 1 131 132 135 140 136 137 140 145 1 141 142 145 150 1 147 149 152 157 MBh 57.7 58.4 60.1 62.7 57.2 57.9 59.6 62.2 55.7 56.5 58.2 60.7 53.2 54.0 55.6 58.2 50.1 50.9 52.6 55.1 47.3 48.1 49.8 52.3 S/T 1.00 0.93 0.79 0.6 1.00 0.93 0.80 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.92 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 29 28 24 21 30 29 25 22 1750 kW 3.42 3.41 3.41 3.4 3.84 3.84 3.83 3.9 4.32 4.31 4.31 4.3 4.83 4.83 4.82 4.9 5.41 5.40 5.40 5.4 6.08 6.08 6.07 6.1 Amps 13.0 12.9 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.0 17.2 19.4 19.4 19.4 19.5 22.1 22.1 22.0 22.2 25.2 25.1 25.1 25.3 Hi PR 260 261 262 267 300 301 303 307 342 343 345 350 388 389 391 395 437 438 440 445 490 491 493 497 Lo PR 118 119 122 127 125 126 129 134 131 133 135 140 136 138 141 146 141 143 146 151 148 149 152 157 MBh 58.0 58.7 60.4 63.0 57.5 58.2 59.9 62.5 56.0 56.8 58.5 61.0 53.5 54.3 55.9 58.5 50.4 51.2 52.9 55.4 47.6 48.4 50.1 52.6 S/T 1.00 0.95 0.81 0.7 1.00 0.95 0.82 0.7 1.00 0.98 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.94 0.8 AT 29 27 24 21 29 27 24 21 29 28 24 21 29 27 24 21 29 27 24 20 30 28 25 22 85 1840 kW 3.42 3.42 3.41 3.4 3.85 3.85 3.84 3.9 4.33 4.32 4.31 4.3 4.84 4.84 4.83 4.9 5.41 5.41 5.40 5.4 6.09 6.09 6.08 6.1 Amps 13.0 13.0 12.9 13.1 14.9 14.9 14.9 15.0 17.1 17.1 17.1 17.2 19.5 19.5 19.4 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.1 25.3 Hi PR 260 262 263 268 301 302 304 308 343 344 346 351 389 390 392 396 438 439 441 445 491 492 493 498 Lo PR 119 120 123 128 126 127 130 135 132 133 136 141 137 138 141 146 142 143 146 151 148 150 153 158 MBh 58.2 59.0 60.7 63.3 57.7 58.5 60.2 62.8 56.3 57.1 58.7 61.3 53.8 54.6 56.2 58.8 50.7 51.5 53.2 55.7 47.9 48.7 50.4 52.9 S/T 1.00 0.96 0.83 0.7 1.00 0.97 0.83 0.7 1.00 0.99 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.95 0.8 AT 29 27 24 20 29 27 24 20 29 27 24 21 29 27 24 20 29 27 24 20 30 28 25 21 1920 kW 3.43 3.43 3.42 3.5 3.86 3.85 3.85 3.9 4.33 4.33 4.32 4.4 4.85 4.84 4.84 4.9 5.42 5.42 5.41 5.4 6.10 6.09 6.09 6.1 Amps 13.0 13.0 13.0 13.1 15.0 15.0 14.9 15.1 17.2 17.1 17.1 17.3 19.5 19.5 19.5 19.6 22.1 22.1 22.1 22.2 25.2 25.2 25.2 25.3 HIM 261 262 264 269 302 303 304 309 344 345 347 351 390 391 392 397 439 440 442 446 491 492 494 499 Lo PR 119 121 124 129 126 128 131 136 132 134 137 142 138 139 142 147 143 144 147 152 149 150 153 158 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI Rating Conditions. kW =Total system power Amps = Outdoor unit amps (compressor + fan) k n 0 n G) Q) N O O O H O EXPANDED HEATING DATA GSZB401810A*+AMST24BU1400A* GSZB402410A*+AMST24BU1400A* OUTDOOR AMBIENT TEMPERATURE MBh 28.5 26.7 24.9 23.1 21.2 19.1 17.1 15.5 14.3 13.5 13.0 12.4 10.9 9.4 7.9 6.4 T/R 32.5 30.7 29.0 27.2 26.1 25.1 22.6 20.3 18.4 17.0 16.0 15.4 14.7 12.9 11.2 9.4 7.6 KW 2.0 1.9 1.9 1.8 - 1.8 1.7 1.7 1.6 1.6 1.6 1.5 1.5 1.5 1.4 1.4 1.3 AMPS 7.2 7.1 6.9 6.7 6.5 6.5 6.3 6.1 5.9 5.7 5.5 5.4 5.3 5.1 4.9 4.7 4.5 COP 4.28 4.10 3.92 3.73 3.60 3.50 3.23 2.98 2.77 2.63 2.55 2.50 2.41 2.19 1.94 1.69 1.41 Hi PR 381 368 356 343 336 331 319 306 294 282 269 262 257 244 232 220 207 LO PR 138 129 121 112 107 104 95 86 78 69 61 56 52 44 35 26 18 GSZB403010A*+AMST24BU1400A* GSZB403610A*+AMST36CU1400A* Above information is for nominal CFM and 70 degree indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) kW = Total system power Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 18 www.goodmanmfg.com SS-GSZB4 EXPANDED HEATING DATA (CONT.) GSZB404210A*+AMST42CU1400A* OUTDOOR AMBIENT • 1 47 1 45 40 1 35 30 1 25 20 1 17 15 1 10 5 1 i MBh 51.6 48.3 45.2 42.0 bP.0 38.5 34.8 31.3 28.5 26.4 24.8 24.0 22.9 20.3 17.6 14.9 12.3 T/R 34.3 32.4 30.6 28.7 27.6 26.6 24.0 21.6 19.7 18.2 17.2 16.6 15.8 14.0 12.2 10.3 8.5 KW 3.5 3.4 3.3 3.3 a 3.2 3.2 3.1 3.1 3.0 3.0 2.9 2.9 2.9 2.8 2.7 2.7 AMPS 12.9 12.6 12.4 12.2 12.0 11.9 11.7 11.5 11.2 11.0 10.8 10.6 10.5 10.3 10.0 9.8 9.6 COP 4.38 4.17 3.96 3.74 3.60 3.49 3.21 2.94 2.72 2.56 2.46 2.40 2.31 2.08 1.84 1.59 1.34 Hi PR 394 381 369 356 348 343 330 317 304 292 279 271 266 253 240 227 215 LO PR 131 123 115 107 102 99 91 82 74 66 58 53 50 41 33 25 17 GSZB404810A*+AMST48CU1400A* GSZB406010A*+AMST60DU1400A* Above information is for nominal CFM and 70 degree indoor dry bulb. Amps = Outdoor unit amps (comp.+fan) kW = Total system power Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. SS-GSZB4 www.goodmanmfg.com 19 PERFORMANCE DATA GSZB401830A* + AMST24BU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 615 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 18,250 13,500 4,750 1,160 80 18,050 13,350 4,700 1,230 85 17,800 13,150 4,650 1,290 90 95 100 17,400 000 16,550 12,900 12,600 12,250 4,500 4,400 4,300 1,360 1,430 1,510 105 16,050 11,900 4,150 1,580 110 15,650 11,600 4,050 1,680 115 15,200 11,250 3,950 1,770 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95' 16,400 12,650 3,750 1,430 GSZB403010A* +AMST30BU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 1070 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 30,250 22,700 7,550 1,910 80 29,900 22,450 7,450 2,020 85 29,500 22,150 7,350 2,130 90 95 100 28,850 0• 27,400 21,650 20,600 7,200 6,800 2,250 2,510 105 26,600 20,000 6,600 2,640 110 25,900 19,450 6,450 2,800 115 25,200 18,900 6,300 2,950 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95° 27,200 22,050 5,150 2,370 GSZB402410A*+ AMST24BU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 780 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 24,250 17,700 6,550 1,520 80 23,950 17,500 6,450 1,610 85 23,650 17,300 6,350 1,700 90 95 100 23,150 00 22,000 16,900 16,500 16,050 6,250 6,100 5,950 1,800 1,900 2,010 105 21,350 15,600 5,750 2,120 110 20,800 15,200 5,600 2,250 115 20,200 14,750 5,450 2,380 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95' 21,800 16,550 5,250 1,900 GSZB403610A* +AMST36CU1400A* Conditions: 80 °F IBD, 67 1 IWB @ 1150 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 36,900 26,250 10,650 2,320 80 36,450 25,950 10,500 2,460 85 35,950 25,600 10,350 2,590 90 100 35,200 33,450 25,050 23,800 10,150 9,650 2,740 3,060 105 32,500 23,100 9,400 3,220 110 31,600 22,500 9,100 3,420 115 30,700 21,850 8,850 3,610 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95, 33,150 24,550 8,600 2,890 20 www.goodmanmfg.com SS-GSZB4 PERFORMANCE DATA GSZB404210A* + AMST42CU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 1340 CFM OUTDOOR .TOTAL 75 42,900 31,750 11,150 2,700 80 42,400 31,400 11,000 2,860 85 41,850 31,000 10,850 3,020 90 95 100 40,950 • 00• 38,900 30,350 29,650 28,850 10,600 10,350 10,050 3,190 3,360 3,550 105 37,750 28,000 9,750 3,740 110 36,750 27,250 9,500 3,960 115 35,750 26,450 9,300 4,180 TVA CONDITIONS @ 95° OD DB, 75* ID DB 63* ID WB 95' 38,550 29,700 8,850 3,360 GSZB406010A* + AMST60DU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 1840 CFM OUTDOOR 75 58,950 43,700 15,250 3,830 80 58,250 43,150 15,100 4,070 85 57,500 42,600 14,900 4,310 90 100 56,250 •�• 53,500 41,700 �• • 39,600 14,550 1 13,900 4,570 5,110 105 51,950 38,450 13,500 5,400 110 50,550 37,450 13,100 5,740 115 49,100 36,400 12,700 6,070 TVA Conditions @ 95° OD DB, 75° ID DB 63* ID WB 95' 53,050 40,850 12,200 4,830 GSZB404810A*+ AMST48CU1400A* Conditions: 80 °F IBD, 67 °F IWB @ 1460 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 48,800 35,200 13,600 3,060 80 48,200 34,750 13,450 3,240 85 47,600 34,300 13,300 3,420 90 95 100 46,550 00 44,250 33,550 32,800 31,900 13,000 12,700 12,350 3,620 3,820 4,040 105 42,950 31,000 11,950 4,260 110 41,800 30,150 11,650 4,520 115 40,650 29,300 11,350 4,780 TVA CONDITIONS @ 95° OD DB, 75* ID DB 63* ID WB 95° 43,900 32,900 11,000 3,830 SS-GSZB4 www.goodmanmfg.com 21 DIMENSIONS MODEL DIMENSIONS W.. D" H" GSZB401810A* 29 29 35 11/16 GSZB402410A* 29 29 35 11/16 GSZB403010A* 29 29 39 8/16 GSZB403610A* 35% 35% 39 10/16 GSZB404210A* 35% 35% 3513/16 GSZB404810A* 35% 35Y2 36 7/16 GSZB406010A* 35% 35% 41 10/16 22 www.goodmanmfg.com SS-GSZB4 CONTROLBOX m 0 O O Q v 3 dip 0 3 M ALTERNATE DOUBLE POLE CONTACTOR DFT N w RD + BK BK BK Ellmill. BK RD J I J I RVC J I BK BK I t` MAIN RD CHS PU YIJPK YL Al BR 0 YL PK LPS CM 2 LVJ7 OR 0 —WH W2 COLOR CODE WIRING CODE OUTDOOR POWER SUPPLY —RD R BK---------------BLACK FACTORYWIRING I SEE RATING PLATE SEE NOTE 3 —BLiPK Y BLIPK---------- BLUEIPINKSTRIPE HIGH VOLTAGE — BL c LOW VOLTAGE BR ---- - --------- BROWN �••� SEE NOTE I GR----------------GREEN OPTIONAL HIGH VOLTAGE Ll, SEE NOTE 3 OR --------------- ORANGE FIELD WIRING PU---- ---------- PURPLE HIGH VOLTAGE RD ---- ---------- RED LOW VOLTAGE — — — — WH----------- WHITE YL--------------- YELLOW m� YLIPK--------- YELLOWIPINK m 0 STRIPE 00 o�- COMPONENT CODE C--------------- CONTACTOR i z CADM--•--•-- COMFORT ALERT DIAGNOSTIC MODULE w 0 LU Sc CCR----------- COMPRESSOR CONTACTOR RELAY a a l r CH ------- - - - - CRANKCASE HEATER a CHS........... CRANKCASE HEATER SWITCH CM --------- OUTDOOR FAN MOTOR D RD RD CMR---------- CONDENSERMOTORRELAY COMP ------- COMPRESSOR RD CS ------- ---- COMPRESSOR SOLENOID DC ------- ---- DEFROST CONTROL DFT----------- DEFROST THERMOSTAT DT----•-••-••-- DISCHARGE THERMOSTAT HIPS ------- --- HIGH PRESSURE SWITCH RD HVDR-------- HIGH VOLTAGE DEFROST RELAY -RD IO-------------- INTERNALOVERLOAD LPS---••---- LOW PRESSURE SWITCH 1 C F RCCF LVDR------- LOW VOLTAGE DEFROST RELAY LVJB--------- LOW VOLTAGE JUNCTION BOX RCCF •------ RUN CAPACITOR FOR COMPRESSOR & FAN -YL RVC •••---••-•• REVERSING VALVE COIL RD SA ------- ---- START ASSIST SA SC ------- ---- START CAPACITOR FOR COMPRESSOR (IF USED) SR ------- ---- START RELAY FOR COMPRESSOR NOTE 2 CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. SEE NOTE 4 IF COMP 1 )J! 1 EQUIPMENT GROUND SEE NOTE 3 CH _ NOTES: 1. TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK SEE NOTE 5 & 6 SEE NOTE 1 & 3 & INDOOR THERMOSTAT.. USE N.E.C. CLASS 2 WIRE. 2. START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3. USE COPPER CONDUCTOR ONLY. 4. CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION. CRANKCASE HEATER MAY NOT HAVE ADDITIONAL GROUND WIRE 5.40VA MINIMUM TRANSFORMER IS REQUIRED. 6. COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram or thWARNING e I 7 sources maybe present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. 11) LOW LTAGE 14OR00613-A N A CONTROLBOX BK SR u�o 5 0 0- 2 BL 3 v 3 3 YL 0 3 T y STY L1p L21 BK ALTERNATE DOUBLE POLE CONTACTOR YIJPK BK r(MPU BR I0 CM N (n G) Co Co A I BVPK IBM 01 LVJC OR 0 WH W2 COLOR CODE WIRING CODE RD R BK---------------BLACK FACTORYWIRING PU Y BLIPK---------- BLUE/PINK STRIPE HIGH VOLTAGE L1 BL D BR ---- ---------- BROWN LOW VOLTAGE SEE NOTE 1 GR----------------GREEN OPTIONAL HIGH VOLTAGE—��� SEENOTE3 OR --------------- ORANGE FIELD WIRING PU ---- ---------- PURPLE HIGH VOLTAGE— — RD ---- ---------- RED LOW VOLTAGE — — — w, z WH----------- WHITE MO D Cc YL---------------YELLOW o0 BUPK YLIPK--------- YELLOW/PINK STRIPE F a az COMPONENT CODE WO I BK C--------------- CONTACTOR a p CADM--•--•-- COMFORT ALERT DIAGNOSTIC MODULE a SC CCR----------- COMPRESSOR CONTACTOR RELAY l f CH ------- - - - - CRANKCASE HEATER CHS--•---••-•• CRANKCASE HEATER SWITCH CM --------- OUTDOOR FAN MOTOR RD BL I CMR---------- CONDENSERMOTORRELAY COMP ------- COMPRESSOR CS ------- ---- COMPRESSOR SOLENOID DC ------- ---- DEFROST CONTROL DFT----------- DEFROST THERMOSTAT BK DT----•-••-••-- DISCHARGE THERMOSTAT HIPS ------- --- HIGH PRESSURE SWITCH D HVDR-------- HIGH VOLTAGE DEFROST RELAY -RD 10 -------------- INTERNAL OVERLOAD LIPS ---••---- LOW PRESSURE SWITCH F RCCF LVDR------- LOW VOLTAGE DEFROST RELAY I LVJB--------- LOW VOLTAGE JUNCTION BOX RCCF •------ RUN CAPACITOR FOR COMPRESSOR & FAN YL YL YL ID RVC •••----•--• SA ------- ---- REVERSING VALVE COIL START ASSIST BR RD SA (IF USED) SC ------- ---- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------- ---- START RELAY FOR COMPRESSOR (OPTIONAL) NOTE 2 •• CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. BK B" RD SEE NOTE 4 RP I COMP RVC DT BK I BK _ RD CHS GR YUPK YL 1 EQUIPMENT GROUND I I I CH SEE NOTE NOTES: OUTDOOR POWER SUPPLY SFF RATINf, PI ATF CM '1,-- CHS CH SEE NOTE 4 RV FIELD LOW VOLTAGE INULAM VUVVth JUYF'LY 1. TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK r SEE NOTE 5 & 6 SEE NOTE 1 & 3 & INDOOR THERMOSTAT.. USE N.E.C. CLASS 2 WIRE. 2. START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3. USE COPPER CONDUCTOR ONLY. •y { r 4. CRANKCASE HEATER & CRANKCASE HEATER SWITCH ARE FACTORY INSTALLED OPTION. CRANKCASE HEATER MAY NOT HAVE ADDITIONAL GROUND WIRE 5.40VA MINIMUM TRANSFORMER IS REQUIRED. 6. COMMON SIDE OF TRANSFORMER MUST BE GROUNDED. 014OR00798-B Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram or the I % WARNING sources maybe present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. ul N O UJ O ACCESSORIES # DESCRIPTION 4 :MODEL GSZ134 GSZ1343 34 GSZ134 GSZ134 ABK-20 Anchor Bracket Kit X X X X X X X CSR-U-1 Hard -start Kit X X X X CSR-U-2 Hard -start Kit X X X CSR-U-3 Hard -start Kit X X FSK01A' Freeze Protection Kit X X X X X X X LAKT01 Low -Ambient Kit X X X X X X X OT18-60A2 Outdoor Thermostat w/ X X X X X X X Lockout Stat TXV-FX-KX-2T 3 TXV Kit X X TXV-FX-KX-3T 3 TXV Kit X X TXV-FX-KX-5T 3 TXV Kit X X X OT18-60A2 Outdoor Thermostat X X X X X X TX2N4A 3 TXV Kit X X X X TX31\14 3 TXV Kit X X TX5N43 TXV Kit 0 Contains 20 brackets; four brackets needed to anchor unit to pad ' Installed on indoor coil Z Required for heat pump applications where ambient temperatures fall below 0°F with 50% or higher relative humidity. 3 Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit The TXV should always be sized based on the tonnage of the outdoor unit. All AHRI system ratings are accessible in the System Configurator tool via Partnerl-ink. SS-GSZB4 www.goodmanmfg.com 25 NOTES 26 www.goodmanmfg.com SS-GSZB4 NorEs SS-GSZB4 www.goodmanmfg.com 27 Our continuing commitment to quality products may mean a change in specifications without notice. 02024 OAIKINCOMFORT TECHNOLOGIES MANUFACTURING. L.P. • Houston, Texas • Printed in the USA. 28 www.goodmanmfg.com SS-GSZB4