REVIEWED BLD2024-0180+Structural_Calculations+2.9.2024_4.50.12_PM+4052414Ccivil & structural ENGINEERING engineering & planning RECEIVED Feb 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Design Clarification Memo Port of Edmonds Administration Building Project No. 21060.10 DCM No. 1 To: City of Edmonds Building Department From: Dennis Titus, PE, SE CC: Date: 2/9/24 BLD2024-0180 REVIEWED BY CITY OF EDMONDS A new administration building has been constructed. It is a steel framed building. The roof is framed with steel joists spaced at 6'-0" OC and metal deck. The roof gravity system and building lateral system were both designed with a 5psf allowance over the entire roof. Please refer to the attached design load summary from the original structural calculations. Per the solar panel submittal, the solar array has an average weight of 4.3psf. The structure is adequate to support the weight of the solar array. If any additional information is required, please do not hesitate to contact me. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph.425.778.8500 I f.425.778.5536 www.cgengineering.com Gravity Design Loads Roof DL 18 ga metal deck 3 psf 8" rigid insulation 12 psf (2) gypsum 5.6 psf solar 5 psf mechanical 1.5 psf misc 1 psf joists 5 psf 33.1 psf USE 34.0 psf Floor DL Decking + conc 36.0 psf Insulation 1.0 psf (2) gypsum 5.6 psf Joists 5.0 psf M/E 1.0 psf Misc 1.5 psf 50.1 psf USE 52.0 psf Roof ILL (Snow) 25.0 psf Floor ILL 50.0 psf + 20 psf (partitions) Description Gravity Design Loads By RMK Date 08/02/21 0 Checked Date ENGINEERING Scale Sheet No. 250 4th Ave. South Suite 200 project Port of Edmonds Job No. 2 Edmonds, WA 98020 21160.10