APPROVED BLD RESUB3 BLD2023-0845+STRUCTURAL PLANS+4.26.2024_2.13.59_PM+4221956MELISSA HANNI RESIDENCE STRUCTURAL PLANS Sheet Summary Sheet Description Cover Sheet Soo General Notes Design Criteria Main Deck Detail Sol Lower Deck Detail S02 Upper Deck Extension Detail Connection Details S05 Footing Details S06 Guardrail Details ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE The following documentation shall be available on site for the building inspector: ■ x❑ COE APPROVED ARCHITECTURAL PLAN SET ❑x COE APPROVED STRUCTURAL PLAN SET ; ❑ COE REVIEWED CALCULATION PACKET ' ' ❑ ENERGY CREDIT WORKSHEET ■ ❑ SITE PLAN ; ! ❑ CIVIL PLAN ■ ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ BLD2023-0845 RESUB Apr 26 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL STRUCTURAL NOTES: 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THECONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 3. THE STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. 6. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANU- FACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH THE SUPPLIER'S INSTRUCTIONS AND REQUIREMENTS. 7. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSRUCTION SHALL NOT EXCEED THE SAFE LOAD -CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. THE LIVE LOADINGS UESD IN THE DESIGN OF THIS STRUCTURE ARE INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. 8. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF THESE STANDARDS, UNLESS OTHERWISE NOTED. 9. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL. THE ENGINEER'S REVIEW IS TO BE FOR CONFORMANCE WITH THE DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE RELEVANT CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW, CHECK AND COORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLEY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC. 10. SUBMIT SHOP DRAWINGS IN THE FORM OF TWO BLUELINE PRINTS AND ONE SEPIA. IN NO CASE SHALL REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. AS A MINIMUM, SUBMIT THE FOLLOWING ITEMS FOR REVIEW: A. CONCRETE MIX DESIGN (S). B. REINFORCING STEEL SHOP DRAWINGS. C. STRUCTURAL STEEL SHOP DRAWINGS. D. STEEL JOIST /GIRDER SHOP DRAWINGS. E. METAL DECKING SHOP DRAWINGS. F. PRE -MANUFACTURED WOOD SYSTEM/TRUSS SHOP DRAWINGS (SEE NOTES). G. PRE-ENGINEERED METAL BUILDING SYSTEM (SEE NOTES). OTHER SUBMITTALS MAY BE REQUIRED PER THE "SCHEDULE OF SPECIAL INSPECTIONS" OR THE SEPARATE NOTES CONTAINED HEREIN. 11. UNLESS OTHERWISE INDICATED, ALL ITEMS NOTED TO BE DEMOLISHED SHALL BECOME THE CONTRACTOR'S PROPERTY AND BE REMOVED FROM THE SITE. 12. CONTRACTORS SHALL VISIT THE SITE PRIOR TO BID TO ASCERTAIN CONDITIONS WHICH MAY ADVERSELY AFFECT THE WORK OR COST THEREOF. WOOD MATETRALS: 1. LUMBER ALL WOOD MEMBERS USED FOR LOAD -BEARING PURPOSES, INCLUDING END -JOINTED AND EDGE -GLUE LUMBER, SHALL BE IDENTIFIED BY THE GRADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE AMERICAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE GRADEMARK SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD 20 PS20) AMERICAN SOFTWOOD LUMBER STANDARD. 2. GLULAM GLUE LAMINATED TIMBERS SHALL MEET THE PROVISIONS OF ANSI/AITC A190.1 STRUCTURAL GLUED LAMINATED TIMBER. 3. PREFABRICATED WOOD I -JOISTS ASSEMBLIES USING PREFABRICATED WOOD I -JOISTS SHALL MEET THE PROVISIONS OF ASTM D5055 STANDARD SPECIFICATION FOR ESTABLISHING AND MONITORING STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I -JOISTS , THIS MANUAL, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORT. 4. STRUCTURAL COMPOSITE LUMBER SINGLE MEMBERS OR ASSEMBLIES USING STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVISIONS OF ASTM D5456 STANDARD SPECIFICATION FOR EVALUATIONS OF STRUCTURAL COMPOSITE LUMBER PRODUCTS, THIS MANUAL, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORT. 5. PREFABRICATED WOOD TRUSSES ASSEMBLIES USING PREFABRICATED WOOD TRUSSES SHALL MEET THE PROVISIONS OF THIS MANUAL, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN ANSI/TPI 1 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONNECTION, THE TRUSS DESIGN DRAWINGS, OR THE MANUFACTURER'S CODE EVALUATION REPORT. 6. GYPSUM GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL MEET THE PROVISIONS OF ASTM C 1396/C 1396M, STANDARD SPECIFICATION FOR GYPSUM BOARD 7. HARDBOARD HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL MEET THE PROVISIONS OF ANSI/CPA A135.6 HARDBOARD SIDING. 8. STRUCTURAL PANELS 8.1 ORIENTED -STRAND BOARD (OSB), WAFERBOARD ORIENTED -STRAND BOARD OR WAFERBOARD USE DIN STRUCTURAL APPLICATIONS SHALL MEET THE PROVISIONS OF PS2 OR APPLICABLE CODE EVALUATION REPORTS. 8.2 PARTICLEBOARD PARTICLEBOARD USED IN STRUCTURAL APPLICATIONS SHALL CONFORM TO ANSI A208.1 PARTICEBOARD STANDARD AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORT. 8.3 FIBERBOARD FIBERBOARD USED IN STRUCTURAL APPLICATIONS SHALL MEET THE PROVISIONS OF ASTM C208 STANDARD SPECIFICATION FOR CELLULOSIC FIBER INSULATION BOARD. 8.4 STRUCTURAL PANEL SIDING STRUCTURAL PANEL SIDING USED IN STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF PS1, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION REPORTS. PLYWOOD SHEATHING SHALL BE AS FOLLOWS: U.N.O. ROOF SHEATHING SHALL BE 1/2" CDX INT-APA RATED 32/16, EXP. 1 B.N.:10d common nails at 6" o.c. E.N.:10d common nails at 6" o.c. F.N.:10d common nails at 12" o.c. FLOOR SHEATHING SHALL BE 3/4" T & G INT-APA RATED OSB. B.N.:10d common nails at 6" o.c. E.N.:10d common nails at 6" o.c. F.N.:10d common nails at 12" o.c. FASTENERS AND CONNECTORS: 1. LAG SCREWS LAG SCREWS OR LAG BOLTS SHALL COMPLY WITH ANSI/ASME B18.2.1 SQUARE AND HEX BOLTS AND SCREWS (INC SERIES). 2. TRUSS METAL CONNECTOR PLATES TRUSS METAL CONNECTOR PLATES SHALL MEET THE REQUIREMENTS OF ANSI/TPI 1, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. 3. METAL CONNECTORS WHERE METAL PLATE OR STRAPPING SIZE AND GAGE ARE SPECIFIED, MINIMUM ASTM A653 STANDARD SPECIFICATION FOR STEEL SHEET, ZINC -COATED (GALVANIZED) OR ZINC -IRON ALLOY -COATED (GALVANNEALED) BY THE HOT -DIP PROCESS, STRUCTURAL STEEL, GRADE 33 STEEL SHALL BE USED. OTHER METAL CONNECTORS SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. 4. NAILS NAILS SHALL COMPLY WITH ASTM F1667 STANDARD SPECIFICATION FOR DRIVEN FASTENERS: NAILS, SPIKES, AND STAPLES. 5. PNEUMATIC NAILS AND STAPLES PNEUMATIC NAILS AND STAPLES SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING COE AND ANY ADDITIONAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS. ROUGH FRAMING NAILING SCHEDULE ROUGH FRAMING NAILING SCHEDULE (IN LIEU OF IBC TABLE 2304.10.1) DESIGN CRITERIA NOTES: SEE SHEET S00.1 CONNECTION FASTENING 1. JOIST TO SILL OR GIRDER (3) 0.131 "X3" TOENAILS 2. BRIDGING TO JOIST, RAFTER OR TRUSS (3) 0.131 "X3" TOENAILS EA. END 3. 1X6 OR LESS SUBFLR. JST. (2) 0.131 "X2.5" FACE NAIL 1. THE INTENDED DESIGN STANDARDS AND/OR CRITERIA ARE AS FOLLOWS: LR 4. WIDER THAN 1X6 SUBF. TO JST. (3) 0.131"X2.5" FACE NAIL 5. 2" SUBFLOOR TO JST./GIRDER (2) 0.161 "X3.5" BLIND & FACE NAIL GENERAL INTERNATIONAL BUILDING CODE (IBC 2018, AS AMENDED) 6. SOLE PLATE TO JST. OR BLKG. 0.131"X3" AT 8" O.C. TYP. FACE NAIL CONCRETE ACI 318-14 SOLE PLATE AT BRACED WALL PANEL (4) 0.131 "X3" AT 16" O.C. FACE NAIL 7. TOP PLATE TO STUD (3) 0.131 "X3" END NAIL MASONRY ACI 530/530.1-13 8. STUD TO SOLE PLATE (4) 0.131 "X3" TOENAIL (OR) (3) 0.131" END NAIL STRUCTURAL STEEL ANSI/AISC 360-16 & ANSI/AISC 341-16 9. DOUBLE STUDS AT 0.131"X3" AT 8" O.C. FACE NAIL STEEL JOISTS/GIRDERS SJI 100-15 (& 50-YEAR JOIST DIGEST) 10. DOUBLE TOP PLATES 0.131"X3" AT 8" O.C. TYP. FACE NAIL DOUBLE TOP PLATE LAP SPLICE (20) 0.131"X3" FACE NAILS METAL DECK SDI NC -17 11. JOIST/RAFTER BLKG. TO PLATE (3) 0.131 "X3" TOENAILS COLD -FORMED METAL AISI S100-16 12. RIM JOIST TO TOP PLATE 0.131"X3" AT 6" O.C. TOENAIL 13. TOP PLATE LAP INTERSECTIONS (3) 0.131 "X3" FACE NAIL WOOD ANSI/AWC NDS-18 14. DOUBLE 2X JOIST/HEADER 0.131"X3" AT 12" FACE NAIL EA. EDGE 15. CEILING JOISTS TO PLATE (5) 0.131 "X3" TOENAIL WOOD TRUSSES TPI 1-2014 16. CONTINUOUS HEADER TO STUD (4) 0.131 "X3" TOENAILS FOUNDATIONS SOILS INVESTIGATION AND REPORT PERFORMED BY XXX 17. CEILING JST. LAP AT PARTITIONS (4) 0.131 "X3" FACE NAIL 18. CEILING JST. TO PARALLEL RAFTER (4) 0.131 "X3" FACE NAIL 19. RAFTER TO PLATE (3) 0.131 "X3" TOENAIL 2. DESIGN GRAVITY DEAD LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: SEE S00 20. 1X BRACE TO EA. STUD & PLATE (2) 0.131 "X3" FACE NAIL 21. 1X8 OR LESS SHTG. TO EA. BRG. (2) 0.131"X3" FACE NAIL 22. WIDER THAN 1X8 SHTG. TO BRG. (3) 0.131"X3" FACE NAIL 3. DESIGN GRAVITY LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: SEE S00 23. BUILT-UP CORNER STUDS (3) 0.131 "X3" AT 16" O.C. FACE NAIL 24. BUILT-UP GIRDERS AND BEAMS 0.131"X3" AT 12" FACE NAIL EA. SIDES STAGGERED 4. DESIGN LATERAL LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: SEE S00 5. DESIGN SNOW LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: SEE S00 6. THE LATERAL LOAD RESISTING SYSTEM OF THIS BUILDING CONSISTS OF: SEE S00 EXISTING CONSTRUCTION NOTES: 1. BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING FACILITY, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING STRUCTURAL AND OTHER CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY BRACING, SHORING AND OTHER SAFEGUARDS TO MAINTAIN ALL PARTS OF THE EXISTING WORK IN A SAFE CONDITION DURING THE PROCESS OF DEMOLITION AND CONSTRUCTION AND TO PROTECT FROM DAMAGE THOSE PORTIONS OF THE EXISTING WORK WHICH ARE TO REMAIN. 2. THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, ETC. NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW PORTIONS OF THE WORK TO THE EXISTING WORK. THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR FABRICATION AND ERECTION OF STRUCTURAL MEMBERS. ANY DISCREPANCY SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. WELDING TO AND WITHIN AN EXISTING FACILITY PRESENTS POTENTIAL HAZARDS, INCLUDING: A. FIRE HAZARD- DUE TO THE EXISTING CONSTRUCTION AND BUILDING CONTENTS. B. STRUCTURAL LIQUEFACTION -DUE TO WELDING ACROSS THE FULL SECTION OF STRUCTURAL STEEL MEMBERS. RECOMMENDATIONS TO PREVENT THESE HAZARDS INCLUDE: A. FIRE HAZARD -PROTECT EXISTING COMBUSTIBLES PRIOR TO WELDING. KEEP A SEPARATE WATCHMAN AND SEVERAL FIRE EXTINGUISHERS ON HAND. B. STRUCTURAL LIQUEFACTION -WELD IN SMALL INCREMENTS. ALLOW WELDS TO TO HARDEN BEFORE CONINTUING TO THE NEXT INCREMENT. C. DO NOT LEAVE THE SITE UNTIL SATISFIED THAT NO FIRE HAZARD EXISTS. 4. INFORMATION USED IN PREPARING THESE DRAWINGS WAS TAKEN FROM DRAWINGS PREPARED BY THE FIRM OF [ 1, DATED [ ]. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND ERECTION OF ALL SHORING NECESSARY TO SAFEGUARD THE EXISTING STRUCTURE. THE SHORING SHOWN IS A PARTIAL AND SCHEMATIC REPRESENTATION OF THAT REQUIRED. THE CONTRACTOR SHALL SUBMIT A DETAILED PLAN FOR SHORING, BRACING AND PROTECTION OF THE EXISTING CONSTRUCTION. THE PLAN SHALL INCLUDE A CONSTRUCTION SEQUENCE, BEAR THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE COMMONWEALTH OF VIRGINIA AND BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO BEGINNING THE WORK. LUMBER GRADE/USE SCHEDULE USE/LOCATION SPECIES & SIZE GRADE Fb (PSI) Fv (PSI) Fcp (PSI) Fc (PSI) E (PSI) WALL HEM -FIR (HF.) NO.2 850 150 405 1300 1.3E6 STUDS/BLOCKS 2X, 3X, 4" WIDE, 6" & WIDER WALL PLATES HEM -FIR (HF.) NO.2 850 150 405 1300 1.3E6 2X4, 3X4, 2X6, 3X6 JOISTS HEM -FIR (HF.) NO.2 850 150 405 1300 1.3E6 2X, 3X LEDGER BOARDS DOUGLAS FOR -LARCH (DF.) NO.2 900 180 625 1350 1.6E6 2X,3X LEDGER BOARDS DOUGLAS FOR -LARCH (DF.) NO.1 1000 180 625 1500 1.7E6 4X BEAMS & POSTS DOUGLAS FOR -LARCH (DF.) NO.2 900 180 625 1350 1.6E6 4X BEAMS & POSTS DOUGLAS FOR -LARCH (DF.) NO.1 1200 170 625 1000 1.6E6 6x NAIL SIZE SCHEDUAL NAILS SIZE DIAMETER LENGTH 8d COMMON NAIL 0.131" 2-1/2" 10d COMMON NAIL 0.148" 3.0" 12d COMMON NAIL 0.148" 3-1/4" 16d COMMON NAIL 0.162" 3-1/2" BEARING WALL STUD SCHEDUAL MARK WALL TYPE LOCATION PLATE SIZE STUD SIZE & SPACING BW1 EXTERIOR TYPICAL U.N.O. PER PLAN 2X6 2X6 @ 16" O/C BW2 CRAWL SPACE TYPICAL 2X4 2X4 @ 16" O/C BW2 INTERIOR TYPICAL U.N.O. PER PLAN 2X4 2X4 @ 16" O/C GLULAM BEAMS SIZE SCHEDUAL USE COMBINATION SYMBOL/SPECIES CAMBER SIMPLE SPAN BEAM 24F-V4 DF/DF STANDARD CONTINUOUS BEAM 24F-V8 DF/DF ZERO CANTILEVER BEAM 24F-V8 DF/DF ZERO STRUCUTRAL GENERAL NOTES U.N.O. www.struware.com Code: CODE SUMMARY International Building Code 2018 Live Loads: Roof 0 to 200 sf: 20 psf 200 to 600 sf: 24 - 0.02Area, but not less than 12 psf over 600 sf: 12 psf Typical Floor 40 psf Partitions 15 psf Balconies load 1.5 times live ( ) 60 psf Habitable attics & sleeping areas 30 psf Attics without storage 10 psf Attics with storage 20 psf Dead Loads: Floor 15.0 psf Roof 15.0 psf Wind Design Data: Ultimate Design Wind Speed 110 mph Nominal Design Wind Speed 85.21 mph Risk Category II Mean Roof Ht (h) 8.0 ft Exposure Category C Enclosure Classif. Open Building Internal pressure Coef. +/-0.00 Directionality (Kd) 0.85 Roof Snow Loads: Design Uniform Roof Snow load = 30.3 psf Flat Roof Snow Load Pf = 30.3 psf Balanced Snow Load Ps = 30.3 psf Ground Snow Load Pg = 30.1 psf Importance Factor I = 1.00 Snow Exposure Factor Ce = 1.20 Thermal Factor Ct = 1.20 Sloped -roof Factor Cs = 1.00 Drift Surcharge load Pd = Width of Snow Drift w = Earthauake Desian Data: Risk Category Importance Factor I = 1.00 Mapped spectral response acceleratiol Ss = 131.30 S1 = 46.50 Site Class = code default Spectral Response Coef. Sds = 1.000 Sd1 = 0.569 Seismic Design Category = D Basic Structural System = Bearing Wall Systems Seismic Resisting System = Light frame (wood) walls with structural wood shear panels Design Base Shear V = 0.154W Seismic Response Coef. Cs = 0.154 Response Modification Factor R = 6.5 Analysis Procedure = Equivalent Lateral -Force Analysis CODE SUMMARY- continued Component and cladding ultimate wind pressures Roof Area Negative Zone 1 Negative Zone Negative Zone Positive Zone 1 Positive Zone Positive Zone Surface Pressure (psf) 9 sf < sf < 36 sf -21.8 -21.8 -21.8 -33.5 -33.5 -21.8 -65.4 -33.5 -21.8 24.0 24.0 24.0 36.0 36.0 24.0 48.0 36.0 24.0 www.struware.com LIST OF ABBREVIATIONS; ADD'L ADDITIONAL APPROX. APPROXIMATE ARCH. ARCHITECTURAL ASD ALLOWABLE STRESS DESIGN B. F. BOTTOM FACE B.M. BENCHMARK B.N. BOUNDARY NAILING B.O.B. BOTTOM OF BOREHOLE B.O.T.P. BOTTOM OF TEST PIT BOTT. BOTTOM C CENTIGRADE C.C. CENTER TO CENTER CFM CUBIC FEET PER MINUTE C. 1. CAST IRON C.J. CONSTRUCTION JOINT CLR. CLEAR CMP CORRUGATED METAL PIPE CONC. CONCRETE CONT. CONTINUOUS CT.J. CONTRACTION JOINT DEG. DEGREE DIA. DIAMETER DIAL. DIAGONAL DWL DOWEL E EAST, EASTING EA. EACH E.F. EACH FACE E.N. EDGE NAILING E.J. EXPANSION JOINT EL. ELEVATION E.W. EACH WAY EXIST. EXISTING F FAHRENHEIT F.F. FAR FACE FIG. FIGURE F.N. FIELD NAILING FT. FEET FTG FOOTING FIN. FINISH GA. GAGE GAL GALLON GALV. GALVANIZED GR. GRADE G.L. GRADE LEVEL GPM GALLONS PER MINUTE H.P. HIGH POINT, HORSE POWER HR HOUR HORIZ. HORIZONTAL HT. HEIGHT I.D. INSIDE DIAMETER 1. F. INSIDE FACE INV. INVERT IN. INCH JST JOIST JT. JOINT KIPS KILOPOUNDS LB. POUND L.P. LOW POINT LG. LONG LONG. LONGITUDINAL MAX. MAXIMUM MIN. MINIMUM M.H. MANHOLE MFR. MANUFACTURER NGVD NATIONAL GEODETIC VERTICAL DATUM N NORTH, NORTHING N.I.A. NOT IN CONTRACT N.T.S. NOT TO SCALE N.F. NEAR FACE O/C ON CENTERS O.D. OUTSIDE DIAMETER O.F. OUTSIDE FACE O.H. OVER HANG O.W. OUTLET WORKS P.C. POINT OF CURVATURE P.T. PRESSURE TREATED P.D. PLAIN DOWEL P.I. POINT OF INTERSECTION PL. PLATE PREEAB. PREFABRICATED PSI POUNDS PER SQUARE INCH PSF POUNDS PER SQUARE FOOT PVC POLYVINYL -CHLORIDE R RADIUS RCC ROLLER COMPACTED CONCRETE RCP REINFORCED CONCRETE PIPE REINF. REINFORCEMENT REQD. REQUIRED REV. REVISION S SOUTH SCH. SCHEDULE SH. SHEET S.S. STAINLESS STEEL SECT. SECTION SIM. SIMILAR SIMPS. SIMPSON STRONG TIES S.O.G. SLAB ON GRADE SQ. SQUARE SPEC. SPECIFICATIONS STA. STATION SYM. SYMMETRICAL STD. STANDARD T&B TOP AND BOTTOM T.F. TOP FACE THK. THICKNESS TRANS.TRANSVERSE TOPO. TOPOGRAPHY TYP. TYPICAL T.O.W. TOP OF WALL T.O.F. TOP OF FOOTING U.N.O. UNLESS NOTED OTHERWISE VERT. VERTICAL W WEST W/ WITH W/O WITHOUT W.S. WATERSTOP WSP WOOD STRUCTURAL PANEL Sheet List Sheet Number Sheet Name S00 GENERAL STRUCTURAL NOTES S01 LOWER DECK FOUNDATION & FRAMING PLAN S02 UPPER DECK FRAMING SD05 TYPICAL STRUCTURAL DETAILS W 6 HAJ Wilson & HAJ Consultant Engineers, LLC NOTES: 1-THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF (WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ CONSULTANT ENGINEERS, LLC) IS PROHIBITED. 2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND / OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ENCLOSED DRAWING. WILSON & HAJ CONSULTANT ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO CONSTRUCTION AND BE SOLELY RESPONSIBLE THEREAFTER. 3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. 0 O O 3: W U LLI 0 a1 = N U) z 0 O J LU U � C CV J co � 0) j j -O -O 70 O Q Z3 ui O -6 U O N � O o m E D- ti w Revisions Rev# Description Date GENERAL STRUCTURAL NOTES Project number Project Number Date 0401 2023 Drawn By Author Checked By Checker BLD2023-0845 SOO RESUB Scale Pr s In Icated DEVELOPMENT SERVICES DEPARTMENT 6X6 PT POST FOUNDATION GENERAL NOTES: 2 3 4 5 6 7 8. 9. 10 11 12 13 DECKING TO (2) 16d @ EA. DECK FOUNDATION AND FRAMING PLAN 1 /4" = 1'-0" THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC FOR THE STRUCTURE DURING CONSTRUCTION. USE THIS DRAWING IN CONJUNCTION WITH ARCHITECTURAL, STRUCTURAL/FRAMING AND OTHER DISCIPLINES. ELEVATIONS & DIMENSIONS SHOWN ON THIS DRAWINGS SHALL BE FOR THE PURPOSES OF PLACING REINFORCING BARS ONLY, NOT FOR CONSTRUCTION UNLESS VERIFIED BY THE CONTRACTOR. REFER TO SHEET S00 FOR ADDITIONAL REQUIREMENTS & SHEET SD05 FOR FOUNDATION DETAILS. U.N.O. CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL HOLD DOWNS SHOWN. ALL FOOTINGS SHALL BEAR ON UNDISTURBED, FIRM NATURAL SOIL OR COMPACTED FILL CAPABLE OF SUPPORTING A DESIGN BEARING PRESSURE OF 1,500 PSF. CONCRETE WORK SHALL CONFORM TO ACI 318 " BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY CONCRETE SPECIFICATIONS SHALL CONFORM TO ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE". ALL DETAILS SHALL BE IN ACCORDANCE WITH ACI 315 & ACI DETAILING MANUAL. REIN. STEEL BARS SHALL CONFORM TO ASTM 615/GRADE 60. SPECIFIED CONCRETE STRENGTH SHALL BE f'c=2,500PS1 @ 28 DAYS FOR FOOTINGS & WALLS. U.N.O. MAX. AGGREGATE SIZE SHALL BE 3/4in, MIN. AIR CONTENT SHALL BE 5% (TOLERANCE-+1.5%) (BY VOLUME), MAX. SLUMP SHALL BE 6". ALL REIN. BAR SPLICES ARE TO BE CLASS B TENSION SPLICES. WALL HORIZONTALS ARE TO BE CONSIDERED "TOP BARS". E.W.=EACH WAY, E.F.=EACH FACE. FRAMING GENERAL NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC FOR THE STRUCTURE DURING CONSTRUCTION. 2. USE THIS DRAWING IN CONJUNCTION WITH ARCHITECTURAL, STRUCTURAL/FRAMING AND OTHER DISCIPLINES. 3. ELEVATIONS & DIMENSIONS SHOWN ON THIS DRAWINGS SHALL BE FOR THE PURPOSES OF PLACING FRAMING & SHEAR WALL LOCATIONS ONLY, NOT FOR CONSTRUCTION UNLESS VERIFIED BY THE CONTRACTOR. 4. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS & TOP PLATE ELEVATIONS. 5. REFER TO SHEET S00 FOR ADDITIONAL REQUIREMENTS. 6. WORK & MATERIALS SHALL CONFORM TO IBC 2018 BUILDING CODE. 7. BEAMS SHOWN SHALL BE DROP U.N.O. ON PLANS. 8. USE SIMPSON (IUS) HANGERS FOR CONNECTION OF I -JOISTS OR TJI JOISTS TO OTHER FRAMING MEMBERS (U.N.O.) AND (LUS) HANGERS FOR CONNECTION OF SOLID JOISTS. 9. POSTS OR ASSEMBLED STUDS SHALL TRANSFER CONTINUOUS LOAD PATH TO FOUNDATION. 10. PROVIDE POSITIVE CONNECTION TO ALL COLUMNS FOR LATERAL FORCES RESISTANCE. 11. ALL LUMBER IN CONTACT WITH SOIL, CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER. 12. ALL HANGERS AND NAILS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE SIMPSON Z-MAX HANGERS OR STAINLESS STEEL. 7z> - � JOISTS DIRECTION &DISTRIBUTION BEAM C JOIST/BEAM/TRUSS HANGER OR CAP PROJECT NORTH DETAIL NUMBER X SDX DETAIL SHEET NUMBER �X BEAM NUMBER PER CALCULATION REPORT 0 2X4 ® 2-2X4 SHALLTRANSFER ®f 3-2X4 CONTINUOUS LOAD PATH TO FOUNDATION ®f 4-2X4 I® f 4X4 POST ® f 6X6 POST FRAMING LEGENDS 1 /4" = V-0" FOOTING DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) REBAR ELEVATION PROJECT NORTH DETAIL NUMBER (SDX DETAIL SHEET NUMBER ® 2X4 ® 2-2X4 ® 3-2X4 ®� 4-2X4 ® 4X4 POST ® 6X6 POST FOUNDATION LEGENDS U 1 /4" = V-0" Wilson & HAJ Consultant Engineers, LLC NOTES: 1-THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF (WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ CONSULTANT ENGINEERS, LLC) IS PROHIBITED. 2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND / OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ENCLOSED DRAWING. WILSON & HAJ CONSULTANT ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO CONSTRUCTION AND BE SOLELY RESPONSIBLE THEREAFTER. 3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. ro) O O N (0 Z = � LIJ � U U) J Lu � >U 0 LIJ z r) D O U) r**� M `' , CV N 0 � N J 00 >< Q U (D O 7 to C: t` E 0-ti 70 LU Revisions Rev# Description Date LOWER DECK FOUNDATION & FRAMING PLAN Project number Project Number Date 0401 2023 Drawn By Author Checked By Checker BLD2023-0845 S01 RESUB Scale Apr 1 = '-0" CITY OF Enmorim DEVELOPMENT SERVICES DEPARTMENT NEW LOWER LEVEL DECK NEW LOWER LEVEL DECK n UPPER DECK FRAMING 1/4" = 1'-0" 6X6, P.T. POST DOWNT DOWN TO FOOTING DECKING TO JOISTS USE; (2) 16d @ EA. JST 6X6, P.T. POST W/ CC66 DOWN TO FOOTING EDGER BOARD tEW WITH WASHER @ 9" GER ROWS TYP. EXISTING MAIN LEVEL COVERED DECK NOTES: 1-THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF (W ILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF (W ILSON & HAJ CONSULTANT ENGINEERS, LLC) IS PROHIBITED. 2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND / OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ENCLOSED DRAWING. WILSON & HAJ CONSULTANT ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO CONSTRUCTION AND BE SOLELY RESPONSIBLE THEREAFTER. 3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. n O O m Z z = U) LIJ � CDLu U U) J � >U OW z 0 D O U) ti CV C) � N J 00 00 � a7 N Q U 7 0 O -O U) O ti O 0- N -0 r UJ Revisions Rev# Description Date UPPER DECK FRAMING Project number Project Number Date 04 01 2023 Drawn By Author Checked By Checker BLD2023-0845 S02 RESUB Scale Apr / - -0" DEVELOPMENT SERVICES DEPARTMENT FTG PER PLAN W/ 1/12 TOP SLOPE (DECK POST DETAILS_ 3/411 = 11-011 P.T. POST PER PLAN POST BASE CBSQ44 FOR 4X4 POST CBSQ66 FOR 6X6 POST \ GRADE LEVEL <.a d' 4 ,d ; .4a ad 4 a -,- -1LOW FROST LEVEL SIZE PER PLAN Vo 4 o Z MIN. � 9 4- dp _ - L 4 �' n p, - 6" 8 MIN., a 0 6 o MIN. _ 'v DIAMETER PER PLAN MIN. 14" DECK POST AND CONCRETE PIER 3/411 = 1'-01' 3-2X12 JST FLR SYSTEM 2X12 STRINGER@ 18" SEE ARCH. DRAW'G WOOD STAIR DETAILS 3/4" = 1'-0" P.T. POST PER PLAN (2)-1/2" THROUGH ROD OR BOLT IN BOTH DIRECTIONS 1/12 SLOPE G.L. CONCRETE PIER PER PLAN (2)-1/2" THROUGH ROD OR BOLT IN BOTH DIRECTIONS WELL -GRADED GRAVEL 2X4 W/' EA. WOOD BEAM TO END CQLLUMN BRACING 3/411 = 11-011 CC COLUMN CAP. INSTALL PER MANUFACTURER'S RECOMMNENDATION o 4'-0" o O O JNECTOR PER PLAN 6X6 POST 2X BLOCKING W/ (3 BLOC aJOIST TO BEAM CONNECTION 3/4 11-011 BEAM SPLICE WHERE OCCURS CMSTC16 STRAP EACH SIDE AS REQUIRED BEAM PER PLAN ECC COLUMN C/ INSTALL PER MANUFACTUREF RECOMMNENDA POST PER PLAN AT CONTINUOUS BEAM AT END BEAM BEAM COLUMN CONNECTION 3/4" = 1'-0" 0' - 10" 4 BOARDS MIN. TREADS; 2X OR 514 BOARDS h "NOSE ��' i-I 1"NOSE 3"X"3X1/4"X0'-3" ANGLE W/ 1/2" BOLT @ EA. LEG & @ EA. STRINGER 2X12 STRINGER@ 18" O/C MAX. SEE ARCH. DRAW'G 4" S.O.G. S.O.G. LEVEL _ of- 244 a FROST DEPTH 0'-4" 0'-6" 0'-4" -S @ 6" O/C FLR SYSTEM CUT POST AT BOTTOM TREAD ELEVATION WHEN NO STAIR GUARI STAIR STRINGE 4x4 P 10"x10" SQUARE OF 12" DIA. FOOTING SECTION (2) 1/2" DIAMETER THROUGH -BOLTS WITH WASHERS REQUIRED ONLY IF GUARD IS REQUIRED; OTHERWISE USE (2) #8 WOOD SCREWS a3-1/2" LONG OR (2) 16d THREADED NAILS ATTACH 2x4 BEARING BLOCK USING (8) #8 WOOD SCREWS a3-1/2" LONG OR (8) 16d THREADED NAILS — FLR LEVEL DST DEPTH JOISTS PER PLAN H1 TIE @ E.A. JST FLOOR PER FLOOR JOISTS NOTE: THIS DETAIL IS APPLICABLE WHERE FLOOR JOISTS ARE PARALLEL TO DECK JOISTS. DECK ATTACHMENT FOR LATERAL LOADS 'IIIIIVV G ASHING FOR WATER TIGHTNESS A DECKING / 1/4" GAP 'PROVED JOIST HANGERS 3E;SIMPS. LUS28 HANGER 8 MIN. P.T. LEDGER JST BE EQUAL OR GREATER THAN THE RAFTER SIZE / 1/2-INCH LAG SCEW @ 9" O/C (STAGGAR FASTENERS 2 ROWS) HOLD-DOWN DEVICE MIN 750 LB. CAPACITY AT 4 LOCATIONS, EVENLY DISTRIBUTED ALONG DECK AND ONE WITHIN 24" OF EACH END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD- DOWN MANUFACTURER. A FULLY THREADED 3/4" DIAMETER LAG SCREW PREDRILLED W/ MIN. 3" PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER. STAGGER FASTENERS IN 2 ROWS PER PLAN 5.5"MIN. FOR 2X8 6.5"MIN. FOR 2X10 X in 7.5"MIN. FOR 2X12 �o 'v m LAG SCREW, THROUGH -BOLT OR A.B. WITH WASHER P.T. LEDGER LEDGER BOARD DETAILS NOTES: 1-THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF (W ILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF (W ILSON & HAJ CONSULTANT ENGINEERS, LLC) IS PROHIBITED. 2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND / OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ENCLOSED DRAWING. WILSON & HAJ CONSULTANT ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO CONSTRUCTION AND BE SOLELY RESPONSIBLE THEREAFTER. 3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. 0 O O m co Z = U) LIJ CD U U) J LU >U 0 LU z D O U) MP**-. C' J CAI C) � N J 00 00 � a7 N 0 Q U O 0 O -O U) O O 0- N -0 r LU Revisions Rev# Description Date TYPICAL STRUCTURAL DETAILS Project number Project Number Date 04 01 2023 Drawn By Author Checked By Checker BLD2023-0845 SD05 RESUB Scale pr ' died 3/41' = 1'-01 ' DEVELOPMENT SERVICES DEPARTMENT RFX238FF FLAT --\ RFX200. RFX300 OR Rn1) MAX PFT\A/FFN PrIl�-,TC � 1 /8" OR 3 /16" SS =ILLER INFILL RFX400 TOP RAIL 1X19 CABLE INFILL OR RF; 36" OR 42" US POS MOl RFXRCB — RAIL CONNECTING RFXPF PICKET — FILLER RFXBR BOTTOM RAIL OPTIONAL BLOCK — SEE SHEETS 6 & 7 RFXFMINT — 1" OFFSET FASCIA MOUNT BRACKET SEE OTHER OPTIONS ON SHEETS 10 & 11 RFX 200 / RFX300 ALUMINUM RAIL W/STAINLESS STEEL CABLE INFILL OFFSET FASCIA MOUNT RFXFBDOC 1" STANDOFF FASCIA MOUNT OUTSIDE RFXF51 C 1" STANDOFF FASCIA MOUNT RFXFBST 1" STANDOFF FASCIA MOUNT CORNER DOULBE POST BRACKET (GLASS FILL 4.94 (1" PIN MAY BE USED FOR OPTIONAL HINGED CORNER BRACKET ASSEMBLY) 0.25 75" 0.75" BX 00.25 FOR HW-14-1 #14 X 1 SS HEX WASHER SELF DRILLING SCREW 1" 4X 00.25 FOR HW-14-1 #14 X 1" SS HEX WASHER SELF DRILLING SCREW 6" Scale: 1-1/2": 1'-0" CEC200/RFXEC300 RFXEC200EXP/ �CEC300EXP END CAP -D WITH SCREWS �T WITH CORE JNTED IN CONCRETE 3.75 MAX. K,/_,TF_r RFXF50C 1" STANDOFF FASCIA MOUNT INSIDE CORNER POST BRACKET INTERMEDIATE POST BRACKET OUTSIDE CORNER POST BRACKET 5.47" 4X 07/16" FOR 3/8' ATTACHMENTS 4X s�7/16" FOR—' ----4X 07/16 FOR 3/8" ATTACHMENTS 3/8" ATTACHMENTS i� I" OFFSET FASCIA MOUNT BRACKET — POST ATTACHMENT OPTIONS AND DETAILS RFX238P WITH RFXPS 4X HEX-3/8—LAG-10.00—SS 3/8 X 10 HEX HEAD LAG SCREW w/MIN. 5" OF THREAD LENGTH 4x RFXPCAP 4 x C W— 3/8— Z P 3/8„ SS CUP WASHER SECTION L—L OFFSET FASCIA MOUNT TO WOOD 4X 00.25 FOR HW-14-1 #14 X 1" SS HEX WASHERO TYP . 4X 0 7/6" FOR 3/8„ ATTACHMENTS CONCRETE SECTION M—M OFFSET FASCIA MOUNT TO CONCRETE RFX238P WITH RFXPS 1. DESIGN CAPACITY CHECK OF EXISTING STRUCTURE THAT SUPPORTS THE RAILING IS NOT IN ZENITH SCOPE OF WORK. 2. RAILING IS DESIGNED FOR MAX SPEED OF 110MPH. 3. CABLE IN —FILL & TOP RAIL DESIGN IS NOT IN ZENITH SCOPE OF WORK. 4. POST SPACING OF 5' O.0 REQUIRES RFS238P (POST) WITH RFXPS (STIFFENER). 4X 00.25 FOR H W-14-1 #14 X 1" SS HEX WASHER SELF DRILLING SCREW RFXFBST 4X HIT—HY 200 V3 + HIT—Z 3/8" CONCRETE ANCHOR BOLT 2 3/4" MIN. EMBED. 4X RFXPCAP Scale: 5":1'-0" 4X CW-3/8—ZP 3/8" SS CUP WASHER 2_37F�, RFX238P RFX STANDARD POST X—SEC 2.142" RFX238P WITH RFXPS (STIFFINER� HOLE MUST BE IN LINE WITH STIFFINER PE -POST EXTRUSION PROFILE T^� RAIL PROFILES CABLE II RFX238F LAT FILL RFX238P RAILFX POST Scale: 1'-0":1'-0" [DE-vznn T')P RAIL TOP RAIL PROFILES (CONTIUOUS TOP RAIL ZENITH ENGINEERS, INC 22320 Foothill Blvd, Suite 600 Hayward, CA 94541 www.zenithenginers.com Q�pFESSIpN p,L M Zt� � CID C 78688 � EXP.09/30/2023 qTF OF CAL\Fps W Q O DATE: 09.22.2022 SCALE: AS SHOWN DESIGN BY: HM DRAWN BY: SSK REVIEWED BY:SP 190417 Scale: 5":1'-0" Scale: 5":1'-0" Scale: 1'-0":1'-0" PAGE O T;� _K DEPARTMENT