BLD2024-0936_Manufacturer_Specifications_and_Installation_Instructions_7.18.2024_2.47.12_PM_4387568
Heat Pumps RP18AZ The new degree of comfort'' Endeavor® Line Prestige® Series Heat Pumps SP\Nge w9 ffl� This product meets a stRngent set of our internally de/inetl sustainabilM standards N 71. 0�)EcoNet R P 18AZ Cooling Efficiencies up to: 20.0 SEER2/12.5 EER2 Heating Efficiency: 8.5 HSPF2 Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW] Cooling Capacities 22.8 to 55.0 kBTU [6.7 to 16.1 ENERGUIDE ISO C us �i CERTIFIED bOO1:2015 kW] t A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners. *Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov. FORM NO. P11-823 REV. 3 Table of Contents RP18AZ Table of Contents Features & Benefits..................................................................3 Model Number Identification....................................................4 General Data/Electrical Data....................................................5 Accessories..............................................................................6 Unit Dimensions.......................................................................7 Clearances...............................................................................8 Refrigerant Line Size Information ....................................... 9-10 Capacity Ranges.............................................................. 11-14 PerformanceData..................................................................15 Smart Home Systems............................................................16 LimitedWarranty....................................................................20 2 Features and Benefits RP18AZ Features and Benefits • EcoNet® Enabled: Automatic system configuration and optimization • PlusOne® Diagnostics & Bluetooth®1 Connectivity: With the Rheem Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before • Variable Speed Scroll Compressor & Inverter Drive: — Features variable speed operation from 40 to 100% capacity with the EcoNet@ Smart Thermostat — Offers overdrive capability up to 115% to maintain performance in extreme conditions — Provides precise temperature control, advanced humidity control and greater efficiency • Brushless DC Condenser Motors (BLDC): Enhances reliability and allows for easier serviceability • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics 'The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners. Model Number Identification RP18AZ R P 18 A Z 24 A J V N A Brand Product SEER2 Region Refrigerant Capacity Major Series Voltage Type Controls Minor Series Category R - Rheem P - Heat Pump 18 -18 SEER2 A - All Regions Z - R-410A 24 - 24,000 [7.03 kW] A -1st Design J - 208/230/1/60 V - Fully Variable C -Communicating A- Ist Design 36 - 36,000 [10.55 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] [ ] Designates Metric Conversions AVAILABLE MODELS DESCRIPTION RP18AZ24AJVCA EndeavorO Line PrestigeO Series 2 ton EcoNet@ Enabled Inverter Driven Variable Speed iM Heat Pump - 208/230/1/60 RP18AZ36AJVCA Endeavor® Line Prestige® Series 3 ton EcoNet® Enabled Inverter Driven Variable Speed iM Heat Pump - 208/230/1/60 RP18AZ48AJVCA Endeavor® Line Prestige@ Series 4 ton EcoNet@ Enabled Inverter Driven Variable Speed iM Heat Pump - 208/230/1/60 RP18AZ60AJVCA Endeavor® Line Prestige® Series 5 ton EcoNet® Enabled Inverter Driven Variable Speed iM Heat Pump - 208/230/1/60 STANDARD EQUIPMENT R-410A Refrigerant EcoNet@ Enabled Variable Speed Compressor Compressor Sound Blanket Variable speed outdoor fan motor Swept wing fan blade Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Low Ambient capability 3-4-5 Expanded Valve Space Composite Basepan 1" Screw Control Box Access Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws OR code External gauge ports Service trays 4 General Data/Electrical Data RP18AZ General Data MODEL NO. RP18AZ24AJVCA RP18AZ36AJVCA RP18AZ48AJVCA RP18AZ60AJVCA Nominal Tonnage 2.0 1 3.0 4.0 5.0 Valve Connections Liquid Line O.D. — in. 3/8 3/8 3/8 3/8 Suction Line O.D. — in. 3/4 3/4 7/8 7/8 Refrigerant (R410A) furnished oz.' 210 212 222 252 Compressor Type Scroll Outdoor Coil Net face area — Outer Coil 28.3 32.5 32.5 32.5 Net face area — Inner Coil — — — — Tube diameter— in. 0.375 0.375 0.375 0.375 Number of rows 1 1 1 1 Fins per inch 20 20 20 20 Outdoor Fan Diameter — in. 26 24 24 26 Number of blades 3 3 3 3 Motor hp 1/2 1/2 1/2 1/2 Shipping weight — lbs. 282 306 306 309 Operating weight — lbs. 278 298 298 301 Electrical Data Line Voltage Data (Volts -Phase -Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)2 30 50 60 60 Minimum circuit ampacity3 22 32 37 42 Compressor Rated load amps 15.4 24 28.1 31.7 Locked rotor amps 35 50 50 50 'Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 313efer to National Electrical Code manual to determine wire, fuse, and disconnect size requirements. Accessories/Weighted Sound Power RP18AZ Accessories MODEL NO. RP2024 RP2036 RP2048 RP2060 EcoNet@ Smart Thermostat RETST800SYS RETST800SYS RETST800SYS RETST800SYS Heat Pump Riser 6 in. 686020 686020 686020 686020 Supply/Return Sensor RXHT-A02 RXHT-A02 RXHT-A02 RXHT-A02 Weighted Sound Power Level (dBA) RP18AZ SOUND POWER LEVEL SOUND POWER FULL OCTAVE LINEAR SOUND POWER LEVEL DB - SOUND POWER MODEL LEVEL [DB(A)] LOW SPEED/ CENTER FREQUENCY - HZ LEVEL [DB(A)] WITH SOUND HIGH SPEED 125 250 500 1000 2000 4000 6300 8000 BLANKET 59 34.8 39.7 50.8 48.4 42.5 40.2 34.6 34.5 RP18AZ24AJVCA 69 45.0 50.6 59.5 57.9 56.6 49.5 45.7 44.8 RP18AZ36AJVCA 60 33.6 38.3 57.6 48.2 43.6 39.7 43.0 39.3 Sound 70 44.8 51.1 60.8 60.1 56.2 50.3 49.9 48.3 RP18AZ48AJVCA 59 34.0 38.9 52.3 48.0 43.5 39.8 42.2 37.3 Blankets - Standard 73 48.5 54.4 65.4 63.1 58.0 55.0 53.3 51.6 RP18AZ60AJVCA 58 36.0 39.3 51.4 46.2 43.8 43.0 41.3 40.2 73 49.8 54.0 68.0 59.2 55.9 53.7 50.7 49.3 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) Unit Dimensions RP18AZ Unit Dimensions MODEL NO. OPERATING SHIPPING H (Height) L (Length) W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RP18AZ24AJVCA 45.17 1147 36.13 918 36.13 918 48.18 1224 39.37 1000 39.64 1007 RP18AZ36AJVCA 51.17 1300 36.13 918 36.13 918 53.56 1360 39.37 1000 39.64 1007 RP18AZ48AJVCA 51.17 1300 36.13 918 36.13 918 53.56 1360 39.37 1000 39.64 1007 RP18AZ60AJVCA 1 51.17 1 1300 1 36.13 1 918 1 36.13 918 1 53.56 1360 1 39.37 1000 39.64 1007 ALLOW 60" [1524 mm] OF CLEARANCE CE PANELS/ CONNECTIONS / HIGH & LOW GE ACCESS V 24" [610 mm] OF CLEARANCE nln llmuLI LVu V LnJ nL"VVV 6" [152 mm] MIN. OF CLEARANCE ALL SIDES 12" [305 mm] RECOMMENDED [ ] Designates Metric Conversions ST-A1226-02-00 co �all CLEARANCES CD WALL 6" (152.4) 24" 12" 609.E 304.8 ( ) Service 6" (152.4) 24" (609.6) Service 18" 24" (457.2) (609.6) 24" recommended 6" minimum 12" (304.8) WALL 24" 24" (609.6) (609.6) Service Service 24" (609.6) 24" recommended 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT. When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re -circulation of discharge air. ST-A 1225-01-00 Refrigerant Line Size Information RP18AZ Refrigerant Line Size Information 18 SEER2 VARIABLE SPEED HEAT PUMPS UNIT SIZE ALLOWABLE LIQUID LINE SIZE ALLOWABLE VAPOR LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET) < 25 26-50 51-75 76-100 101-125 126-150 MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER 1/4" 5/8" 25/1.00 50/0.99 33/0.98 60/0.97 NR NR 5/16" 5/8" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.96 50/0.95 2.0 TON `SEE 3/8" 5/8" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.96 50/0.95 NOTE 3 1/4" 3/4- 25/1.00 50/1.00 33/0.99 60/0.99 NR 5/16" 3/4- 25/1.00 50/1.00 50/0.99 50/0.99 50/0.99 50/0.98 3/8" 3/4- 25/1.00 50/1.00 50/0.99 50/0.99 50/0.99 50/0.98 5/16" 5/8" 25/0.99 50/0.97 50/0.95 50/0.93 36/0.91 Wr NR 3/8" 5/8" 25/0.99 50/0.97 50/0.95 50/0.93 50/0.91 NR 3 TON 5/16" 3/4" 25/1.00 50/0.99 50/0.99 50/0.98 36/0.97 20/0.96 3/8" 3/4" 25/1.00 50/0.99 50/0.99 50/0.98 50/0.97 50/0.96 1/2" 3/4" 25/1.00 50/0.99 50/0.99 50/0.98 50/0.97 50/0.96 3/8" 3/4" 25/0.99 50/0.98 50/0.96 50/0.95 50/0.93 50/0.92 4 TON 1/2" 3/4" 25/0.99 50/0.98 50/0.96 50/0.95 50/0.93 50/0.92 3/8" 7/8" 25/1.00 50/0.99 50/0.99 50/0.98 50/0.98 50/0.97 1/2" 7/8" 25/1.00 50/0.99 50/0.99 50/0.98 50/0.98 50/0.97 3/8" 3/4" 25/0.98 50/0.97 50/0.95 50/0.93 46/0.91 NR 1/2" 3/4" 25/0.98 50/0.97 50/0.95 JJL 50/0.93 50/0.91 NR 5 TON 3/8" 7/8" 25/0.99 50/0.99 50/0.98 50/0.97 50/0.96 38/0.95 1/2" 7/8" 25/0.99 50/0.99 50/0.98 50/0.97 50/0.96 50/0.95 3/8" 1-1/81- 25/1.00 50/1.00 50/1.00 1 50/0.99 50/0.99 38/0.99 1/2" 1-1/8-* 25/1.00 50/1.00 1 50/1.00 1 50/0.99 50/0.99 1 50/0.99 NOTES: 1) Do not exceed 150 ft. linear line length. 2) Do not exceed 50 ft. vertical separation between indoor and outdoor units. 3) *3/4" vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) **1-1/8" vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 5) Always use the smallest liquid line allowable to minimize refrigerant charge. 6) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 7) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information RP18AZ Refrigerant Line Size Information (Con't.) 18 SEER2 VARIABLE SPEED HEAT PUMPS UNIT SIZE ALLOWABLE LIQUID LINE SIZE ALLOWABLE VAPOR LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS) < 8 9-15 16-23 24-30 31-38 39-46 MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER 6.35 [1/4] 15.88 [5/8] 8/1.00 15/0.99 10/0.98 20/0.97 NR NR 7.0 kW 7.94 [5/16] 15.88 [5/8] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.96 15/0.95 [2.0 TON] 9.53 [3/8] 15.88 [5/8] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.96 15/0.95 *SEE 6.35 [1/4] 19.05 [3/4] 8/1.00 15/0.99 10/0.99 20/0.99 NR NR NOTE 3 7.94 [5/16] 19.05 [3/4] 8/1.00 15/0.99 15/0.99 15/0.99 15/0.99 15/0.98 9.53 [3/8] 19.05 [3/4] 8/1.00 15/0.99 15/0.99 15/0.99 15/0.99 15/0.98 7.94 [5/16] 15.88 [5/8] 8/0.99 15/0.97 15/0.95 15/0.93 11/0.91 NR 9.53 [3/8] 15.88 [5/8] 8/0.99 15/0.97 15/0.95 15/0.93 15/0.91 NR 10.6 kW [3 TON] 7.94 [5/16] 19.05 [3/4] 8/1.00 15/0.99 15/0.99 15/0.98 11/0.97 6/0.96 9.53 [3/8] 19.05 [3/4] 8/1.00 15/0.99 15/0.99 15/0.98 15/0.97 15/0.96 12.70 [1/2] 19.05 [3/4] 8/1.00 15/0.99 15/0.99 15/0.98 15/0.97 15/0.96 9.53 [3/8] 19.05 [3/4] 8/0.99 15/0.98 15/0.96 15/0.95 15/0.93 15/0.92 14.1 kW 12.70 [1/2] 19.05 [3/4] 8/0.99 15/0.98 15/0.96 15/0.95 15/0.93 15/0.92 [4 TON] 9.53 [3/8] 22.23 [7/8] 8/1.00 15/0.99 15/0.99 15/0.98 15/0.98 15/0.97 12.70 [1/2] 22.23 [7/8] 8/1.00 1 15/0.99 15/0.99 15/0.98 15/0.98 15/0.97 9.53 [3/8] 19.05 [3/4] 8/0.98 15/0.97 15/0.95 15/0.93 14/0.91 NR 12.70 [1/2] 19.05 [3/4] 8/0.98 15/0.97 15/0.95 15/0.93 15/0.91 NR 17.6 kW 9.53 [3/8] 22.23 [7/8] 8/0.99 15/0.99 15/0.98 15/0.97 15/0.96 12/0.95 [5 TON] 12.70 [1/2] 22.23 [7/8] 8/0.99 15/0.99 15/0.98 15/0.97 15/0.96 15/0.95 9.53 [3/8] 28.58 [1-1 /8] * * 8/1.00 15/0.99 15/0.99 15/0.99 15/0.99 12/0.99 12.70 [1/2] 28.58 [1-1/8]** 1 8/1.00 1 15/0.99 15/0.99 1 15/0.99 1 15/0.99 1 15/0.99 NOTES: 1) Do not exceed 46 meters linear line length. 2) Do not exceed 15 meters vertical separation between indoor and outdoor units. 3) *19.05mm [3/4"] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4) **28.58mm [1-1/8"] vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 5) Always use the smallest liquid line allowable to minimize refrigerant charge. 6) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed. 7) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. 10 Capacity Ranges RP18AZ 35,000 30,000 25,000 20,000 x H m 15,000 10,000 5,000 0 (-)P18AZ24 Cooling Capacity Ranges 60° [16°] 70` [21°] 80° [27°] 90° [32°] 100° [38°] 110° [431 OUTDOOR DB °F [°C] (-)P18AZ24 Heating Capacity Ranges 10.3 8.8 7.4 5.9 Y 4.4 2.9 1.5 0.0 50,000 — 14.7 45,000 — 13.2 40,000 — 11.8 35,000 10.3 30,000 — 8.8 x 25,000 — 7.4 Y m 20,000 — 5.9 15,000 4.4 10,000 2.9 5,000 1.5 0 T 0.0 -10°[-23°] 0° [-18°] 10° [-12°] 20° [-7°] 30° [-1°] 40° [4°] 50° [10°] 60° [16°] OUTDOOR DB I [°C] Capacity Ranges RP18AZ 50,000 45,000 40,000 35,000 30,000 2 25,000 m 20,000 15,000 10,000 5,000 0 80,000 70,000 60,000 50,000 x 40,000 m 30,000 20,000 10,000 0 (-)P18AZ36 Cooling Capacity Ranges 60° [16°] 70- [21°] 80° [27°1 90` [32°] 100° [38°] 110° [431 Outdoor DB °F [°C] (-)P18AZ36 Heating Capacity Ranges -10°[-23°] 0° [-18°] 10° [-12°] 20° [-7°] 30° [-1°] 40° [4°] 50° [10°] 60- [16.1 Outdoor DB °F [°C] 14.7 13.2 11.8 10.3 8.8 7.4 Y 5.9 4.4 2.9 1.5 0.0 23.4 20.5 17.6 14.7 3 Y 11.7 8.8 5.9 2.9 0.0 12 Capacity Ranges RP18AZ 60,000 50,000 40,000 2 30,000 m 20,000 10,000 w (-)P18AZ48 Cooling Capacity Ranges 60° [16°] 70° [21°] 80° [27°] 90° [32°] 100° [38°] 110° [43] Outdoor DB °F [°C] (-)P18AZ48 Heating Capacity Ranges 17.6 14.7 11.7 8.8 Y 5.9 2.9 0.0 80,000 23.4 70,000 20.5 60,000 17.6 50,000 14.7 40,000 11.7 Y m 30,000 8.8 20,000 5.9 10,000 2.9 0 0.0 -10°[-23`] 0° [-18°] 10° [-12°] 20` [-7°] 30° [-1`] 40° [4°] 50° [10°] 60° [16°] Outdoor DB I [°C] 13 Capacity Ranges RP18AZ 80,000 70,000 60,000 50,000 2 40,000 m 30,000 20,000 10,000 0 (-)P18AZ6O Cooling Capacity Ranges 60° [16°] 70` [21-] 80° [27°] 90° [32°] 100° [38°] 110° [43`1 Outdoor DB 'F [°C] (-)P18AZ60 Heating Capacity Ranges i 23.4 i 20.5 17.6 14.7 11.7 Y 8.8 5.9 2.9 0.0 90,000 26.4 80,000 23.4 70,000 20.5 60,000 17.6 50,000 14.7 Y H m 40,000 11.7 30,000 - 8.8 20,000 5.9 10,000 2.9 0 0.0 -10°[-23°] 0° [-18°] 10° [-12°] 20° [-7`] 30° [-1°] 40° [4°] 50° [10°] 60- [16°] Outdoor DB °F [°C] 14 Performance Data RP18AZ Performance Data @ AHRI Standard Conditions- Cooling DESIGNATED TESTED COMBINATION (DTC) TOTAL NET NET 47 DEGREE 47 17 DEGREE 17 REGION OUTDOOR UNIT AIR HANDLER CAPACITY SENSIBLE LATENT SEER2 EER2 INDOOR CFM [L/s] HEATING CAPACITY DEGREE HEATING CAPACITY DEGREE IV BTU/H [kW] BTU/H [kW] BTU/H [kW] BTU/H [kW] COP BTU/H [kW] COP HSPF2 RP18AZ24AJVC RHMVZ2421 HEACA 22800 [6.7] 17500 [5.11 5300 [1.6] 18.0 12.5 785 [370.51 22800 [6.7] 3.00 23000 [6.7] 2.00 8.5 RP18AZ36AJVC RHMVZ6021SEACA 34200 [10.0] 26200 [7.7] 8000 [2.3] 18.0 12.5 1225 [578.11 32000 [9.4] 3.00 37400 [11.0] 2.00 8.5 RP18AZ48AJVC RHMVZ6021SEACA 45800 [13.4] 34500 [10.1] 10500 [3.1] 18.0 12.0 1590 [750.4] 40000 [11.7] 2.50 41000 [12.0] 1.50 8.5 RP18AZ60AJVC RHMVZ6021SEACA 53000 [15.5] 40600 [11.9] 12400 [3.6] 18.0 10.5 1685 [795.21 48500 [14.2] 2.50 47000 [13.8] 1.50 8.5 NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match -ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org. [ ] Designates Metric Conversions 15 Smart Home Systems RP18AZ Integrated Controls 0 EcoNet C EcoNet® is smart, technology developed exclusively by Rheem that allows Heating, Cooling, and Water Heating products to communicate with each other on one integrated network. THE ECONET° SMART THERMOSTAT BUILT-IN WIFI 4.3" LCD TOUCH SCREEN LOCAL WEATHER — Current conditions plus 6-day forecast 5 OPERATING MODES — Heat, Cool, Auto, Emergency Heat and Fan Only 7-DAY PROGRAMMABLE SCHEDULE — Offers comfort without thought ONE -TOUCH AWAY — Quickly switch to your energy -saving away preferences VACATION SCHEDULING —Allows you to save while you're away and come home to comfort STANDBY SCREEN — Displays indoor temperature and current weather OPERATIONAL FEATURES RETST800SYS AUTOMATIC CHANGEOVER — Transitions between heating and cooling automatically to keep the house comfortable INTEGRATED WATER CONTROL — Enables easy water heater management SMOOTH ARRIVAL — Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time HUMIDITY CONTROL — Supports humidifier accessories or over -cool based dehumidification DETAILED OPERATING STATUS — View pertinent equipment status information and run times CONTINUOUS FAN — Offers 5 speeds (Low, Medium Low, Medium, Medium High, High) SHORT -CYCLE PROTECTION — Avoids damage to equipment from short run cycles MONITORING & REMOTE CONTROL FEATURES ACTIVE MONITORING —Alerts to problems that need immediate attention REMOTE CONTROL — Allows adjusting of comfort and settings from anywhere using a mobile device SERVICE ALERTS — Sends routine maintenance reminders AIR FILTER MONITORING — Detects when it's time to replace the air filter ALARM HISTORY — Displays time -stamped alarm codes with clear descriptions Notes RP18AZ 17 Notes RP18AZ 18 Notes RP18AZ 19 / ao The new degree of comfort' GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Unit Replacement which fails in normal use and service within the applicable (Registration Required) ............................ Ten (10) Years period stated, in accordance with the terms of the limited Parts ...................................................... Ten (10) Years warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. © 2023 Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road, Unit 1 Fort Smith, Arkansas 72908 • www.rheem.com Brampton, Ontario • L6Y OP5 • rheem.ca PRINTED IN U.S.A. 12/23 QG FORM NO. P11-823 REV. 3