M_SUBMITTAL_MSZ-GS12NA_MUZ-GS12NA_en_M1Job Name: System Reference: Date: Indoor Unit MSZ-GS12NA Unit, ........................................................................... Outdoor Unit MUZ-GS12NA .......................................................................... INDOOR UNIT FEATURES • Slim wall -mounted indoor units provide zone comfort control • Dual Barrier Coating applied to the heat exchanger, vanes and fan to prevent hydrophilic and hydrophobic dirt build-up • Optional Microparticle Filter designed to capture PM2.5 • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Built-in backup/auxiliary heater control available • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: o Back -lit screen handheld remote controller (provided with the unit) o kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers OUTDOOR UNIT FEATURES • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTM B117 Standard Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal BTU/H 13,600 BTU/H 12,000 BTU/H 1,500 W 1,450 W 920 Pints/h 2.5 Sensible Heat Factor 0.77 95.0 / 95.0 Power Factor [208V / 230V] % Heating at 47°F' Maximum Capacity BTU/H 18,100 Rated Capacity BTU/H 14,400 Minimum Capacity BTU/H 2,000 Maximum Power Input W 1,750 Rated Power Input W 1,100 Power Factor [208V / 230V1 % 97.0 / 97.0 Heating at 17°F' Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,000 Maximum Power Input W 1,670 Rated Power Input W 1,000 Heating at 5°F4 Maximum Capacity BTU/H 9,540 Maximum Power Input W 1,540 Efficiency SEER2 25.6 EER2' 13.05 HSPF2 [IV] 10.7 COP at 47°F2 3.84 COP at 17°F at Maximum Capacity' 2.11 COP at 5°F at Maximum Capacity4 1.82 ENERGY STAR® Certified Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Outdoor) A 15 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.75 Fan Motor Output W 30 Airflow Rate at Cooling, Dry CFM 134-160-222-307-381 Airflow Rate at Cooling, Wet CFM 121-144-200-276-,343 Airflow Rate at Heating, Dry CFM 134-160-222-307-390 Sound Pressure Level [Cooling] dB[A] 19-22-30-37-45 Sound Pressure Level [Heating] dB[A] 19-22-30-37-43 Drain Pipe Size In. [mm] 5/8 [15.881 Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H: In. [mm] 31-7/16 x 9-1/8 x 11-5/8 [798 x 232 x 295] Package Dimensions W x D x H: In. [mm] 33-1/2 x 12 x 14 [850 x 300 x 3501 Unit Weight Lbs. [kg] 23 [10.4] Package Weight Lbs. [kg] 26 [11.5] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) OF 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 10.0 A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Refrigerant Control Linear expansion valve Defrost Method N/A Sound Pressure Level, Cooling' dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC inverter driven Twin Rotary Compressor Model SNB092FQAMT Compressor Rated Load Amps A 6.72 Compressor Locked Rotor Amps A 8.4 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W x D x H: In. [mm] 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550] Package Dimensions W x D x H: In. [mm] 37 x 15 x 24-1/2 [980 x 380 x 630] Unit Weight Lbs. [kg] 79 [35.8] Package Weight Lbs. [kg] 87 [39.2] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -4/0 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -4 DB, -5 WB Heating Thermal Lock -out / Re -start Temperatures** °F -14 / -4 Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 2.0, 9.0 Maximum Pre -Charged Piping Length Ft. [m] 25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 1.08 [20] Piping Gas Pipe Size O.D.[Flared] In.[mm] 3/8 [9.52] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 65 [20] Maximum Height Difference Ft. [m] 40 [12] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47*F (Indoor H Outdoor) *F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Backup Heat Relay Kit Adapter for CN24 or CN152 on ducted models IT Extender for kumo station' ❑ CN24RELAY-KIT-CM3 ❑ PAC-WHS011E-E kumo station' for kumo cloud® ❑ PAC-WHS01 HC-E Control Interface M-Net & 1/0 Control Interface for M-Series Procon BACnet® and Modbus® Interface Thermostat Interface for 3rd Party Thermostats USNAPAdapter for Demand Response Wireless Interface for kumo cloud® ❑ MAC-334IF-E ❑ PAC-UKPRC001-CN-1 ❑ PAC-US445CN-1 ❑ PAC-WHS01UP-E ❑ PAC-USWHS002-WF-2 Remote Temperature Sensor for MFZ, MLZ, and MSZ models ❑ M21 EAA307 Remote Sensor Wireless temperature and humidity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe MA Wired Remote Controllert ❑ PAR-41MAAU Simple Ductless Wired Remote Controller ❑ PAC-SDW01 RC-1 Wired Remote Controller Simple MA Remote Controller ❑ PAC-YT53CRAU-J Touch MA Wired Remote Controller ❑ PAR-CT01 MAU-SB kumo touch' RedLINK' Wireless Controller & Receiver kit ❑ MHK2 Wireless Remote Controller Lockdown Bracket for Wireless Handheld Remote Controllers ❑ RCMKPICB Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 Blue Diamond (MaxiBlue Advanced) Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/H [recommended] ❑ X87-711 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor ❑ X87-835 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank— collection tank for use with multiple pumps ❑ C21-014 Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Drain Pan Level Sensor/Control ❑ SS610E Fascia Kit for MicroBlue Pump, mounts the MicroBlue and sensor directly beneath indoor unit ❑ T18-016 Refco Condensate Pump (100-240 VAC) ❑ GOBI-II Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H ❑ COMBI Sauermann Condensate Pump ❑ S130-230 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Drain Hose Flexible Mini -Split Drain Hose ❑ DRX-16 Filter Anti -allergy Enzyme Filter ❑ MAC-408FT-E NOTES: tRequires MAC-334IF-E " M-Series EZ FIT® Recessed Ceiling Cassette, Floor -mount and Wall -mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Hail Guards Hail Guard 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ HG-B4 ❑ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-30 Lineset 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) Condensing Unit Mounting Pad: 16" x 36" x 3" Optional Defrost Heater 18" Single Fan Stand ❑ MLS143812T-50 ❑ MLS143812T-65 Mounting Pad ❑ ULTRILITEI Optional Defrost Heater ❑ MAC-640BH-U ❑ QSMS1801 M 24" Single Fan Stand ❑ QSMS2401 M Condenser Wall Bracket ❑ QSWB2000M-1 Stand Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Outdoor Unit Stand —12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. t VL. !!...■Ell 9-I/8 3/16 Indoor u 1-3/4 1-15/16 u 24-3/8 1.5-1/8J 2-3/� II • \ • e � M 2-3/16 IS/16 I-3/16 Wireless remote controller Unit: inch Air Insulation o1 - 9/16 O.D c Liquid line o1/4 19 - 11/16 (Flared connection o1/4) a Gas line o3/8 16 - 15/16 (Flared connection: o3/8 (GSO6/09/12NA), o1/2 (GS15NA)) Drain hose Insulation o1-1/8 O.D Connected part o5/8 O.D Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch REQUIRED SPACE *1 4 in. or more when front and sides of the unit are clear a) ore 6 III AIM Air in Drain hole 01-21/32 (09/12/15 Btu/h) e Air in to0 ...... 01- 7= 11101-e C3 e A 0 N � 00.9; *2 When any 2 sides of left, right 1-9/16 � and rear of the unit are clear Air out 2-holes 3/8X13/16 FORM# MSZ-GS12NA& MUZ-GS12NA- 202406 Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Ili Refrigerant pipe (flared) o 3/8 (09/12 KBTU/H) Lnj I IIIIIIIl ',KV 11 1 o 1/2 (15 KBTU/H) 6MEVA91PA 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com C US Intertek Specifications are subject to change without notice. @ 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.