Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-0971_Applicant_Response_7.26.2024_12.05.51_PM_4404388
- ea Ieview,M g In this 3D model, facets appear as semi -transparent to reveal overhangs PREPARED FOR Contact: Larry Miller Company: Gorman Roofing Services Address: 2229 E. University Dr. Phoenix, AZ 85034 Phone: 602-262-2423 Premium Report 4/12/2024 TABLE OF CONTENTS Images.....................................................................1 LengthDiagram.........................................................4 PitchDiagram............................................................5 AreaDiagram............................................................6 NotesDiagram...........................................................7 Penetrations Diagram.................................................8 Report Summary ........................................................9 MEASUREMENTS Total Roof Area =5,962 sq ft Total Roof Facets =16 Predominant Pitch =4/12 Number of Stories >1 Total Ridges/Hips =155 ft Total Valleys =37 ft Total Rakes =411 ft Total Eaves =379 ft Total Penetrations =21 Total Penetrations Perimeter = 137 ft Total Penetrations Area = 80 sq ft Measurements provided by www.eagleview.com laCertified Accurate www.eagleview.com/Guarantee.aspx © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. _eag Ieview- IMAGES The following aerial images show different angles of this structure for your reference. Top View _ •'yAL Premium Report 4/12/2024 © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 1 _ — ea Ieview _ g IMAGES North Side © 2009 PlcbomeGry - �5'%O11r,�0 South Side Premium Report 4/12/2024 © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 2 - _ Ieview- _ g ea IMAGES 110 East Side West Side Premium Report 4/12/2024 © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 3 '/eagleview- LENGTH DIAGRAM Total Line Lengths: Ridges = 126 ft Hips = 29 ft Valleys = 37 ft Rakes = 411 ft Eaves = 379 ft Premium Report 4/12/2024 Flashing = 110 ft Step flashing = 177 ft Parapets = 0 ft E N s if Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,940; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 - Premium Report e ag — I e v i e w 4/12/2024 _ PITCH DIAGRAM Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 4/12 N s w Note: This diagram contains labeled pitches for facet areas larger than 20.0 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 5 _ — ea Ieview- _ g AREA DIAGRAM Total Area = 5,962 sq ft, with 16 facets. Premium Report 4/12/2024 Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non -rounded values of each roof facet (rounded to the nearest square foot after being totaled). © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 6 eagleview NOTES DIAGRAM Roof facets are labeled from smallest to largest (A to Z) for easy reference. Note: This diagram also appears in the Property Owner Report. Premium Report 4/12/2024 E N s w © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,940; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 7 - ea leview g PENETRATIONS NOTES DIAGRAM Penetrations are labeled from smallest to largest for easy reference. Premium Report 4/12/2024 Total Penetrations = 21 Total Penetrations Area = 80 sq ft Total Penetrations Perimeter = 137 ft Total Roof Area Less Penetrations = 5,882 sq ft E N s w © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 8 _/ eagleview REPORT SUMMARY All Structures Premium Report 4/12/2024 The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Waste % 00/0 4% 7% 90/0 11% 14% 19% 24% 29% Area (Sq ft) 5957 6196 6374 6494 6613 6791 7089 7387 7685 Squares * 59.66 62.00 64.00 65.00 66.33 68.00 71.00 74.00 77.00 Measured Suggested * Squares are rounded up to the 1/3 of a square Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide —actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. Any measured penetration smaller than 3.Ox3.0 Feet may need field verification. Accuracy is not guaranteed. The total penetration area is not subtracted from the total roof area. © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 9 ea g — I evi ew- All Structures Totals Lengths, Areas and Pitches Ridges = 126 ft (10 Ridges) Hips = 29 ft (6 Hips). Valleys = 37 ft (4 Valleys) Rakest = 411 ft (34 Rakes) Eaves/Starter$ = 379 ft (25 Eaves) Drip Edge (Eaves + Rakes) = 790 ft (59 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 110 ft (4 Lengths) Step flashing = 177 ft (25 Lengths) Total Penetrations Area = 80 sq ft Total Roof Facets = 16 Total Roof Area Less Penetrations = 5,882 sq ft Total Penetrations =21 Total Penetrations Perimeter = 137 ft Predominant Pitch = 4/12 Total Area (All Pitches) = 5,962 sq ft Premium Report 4/12/2024 Property Location Longitude =-122.3583710 Latitude = 47.7781078 Notes This was ordered as a commercial property. There were no changes to the structure in the past four years. Online Maps Online map of property http://maps.google.com/maps?f=g&source=s q&hl=en&geocode=&q=9501+244th+St+SW,Edmonds,WA,98020 Directions from Gorman Roofing Services to this property http://maps.google.com/maps?f=d&source=s d&saddr=2229+E.+University+Dr.,Phoenix,AZ,85034&daddr=9501+244th+St+SW,Edm onds,WA,98020 t Rakes are defined as roof edges that are sloped (not level). t Eaves are defined as roof edges that are not sloped and level. © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 10 - Legal Notice and Disclaimer — eaa I eview- `J 4/12/2024 9501 244th St SW, Edmonds,98020 '-p• 58245035 IMPORTANT LEGAL NOTICE AND DISCLAIMER Notice and Disclaimer No Warranty: The Copyrighted Materials are provided to you "as is," and you agree to use it at your own risk. EagleView Technologies makes no guarantees, representations orwarranties of any kind, express or implied, arising bylaw or otherwise, including but not limited to, content, quality, accuracy, completeness, effectiveness, reliability, fitness fora particular purpose, usefulness, use or results to be obtained from the Copyrighted Materials. Contractors agree to always conduct a preliminary site survey to verify Roof Report ordered. In the event ofan error in a Report, yoursole remedy will be a refund of the fees paid by you to obtain this Report. © 2008-2024 Eagle View Technologies, Inc. and Pictometry International Corp. — All Rights Reserved — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending.