BLD2024-1032_Manufacturer_Specifications_and_Installation_Instructions_8.7.2024_8.45.26_AM_4425722BUILT TO A HIGHER STANDARD'
Amw�" SAwe&rde
HEATING & AIR CONDITIONING
Submittal
Side Discharge
AC Models
For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models
have an 8 week lead time after order.
Epoxy Coated Model
4A7L5030N 1000A 4A7L5030N 1 COTA
(Vote: "Graphics in this document are for representation
only. Actual model may differ in appearance. "
February 2024 4A7 L5030 N-SUB-1 B-E N
BUILT TO A HIGHER STANDARD*
A*i 6" Sqd d.
HEATING 3 AIR CONDITIONING
Outline Drawing
-,51 fllitrillilI Iwo sx1IMMI G 3.1Kelll 01 ILL uln.
r07. 71 IS•IBAr171 ---...�.-- 77• - ►�� �2TY
Ay1 • 77 75•IBW 14
I'q. 12
rI.R
Cds L11t I/C 1111 IALL SlnlCI SAM. lY
1 1. IMua u.110 CdAKt101 V.I. I,A. $n
ICu1 PI1S7r II IV F.M.K.
PINK
Ion tilt slnlct YAm.
F 1.1. tome "A71
(D.IKIn. Ill. 1,A• 7n
r LAli 11.110t IAr "MICI.
+ H
� F
�_J 1�
FIGI.RE 2
FAIR
KCiss IA.R
IA•I/l
� pl•7/11
.141 rq TlGt
1•I,I
A ALL._
RKt11CAl A10 11111611111
I
E
C010141 (I,, AVE IS
PSI IIIVAILIK COOS.
Ian un nnln
n❑/, F LI. rwtl
III. CC.IKIID.
ur. uA• sA1 run
KI-114_1711111."
m++
r-
GAS Lilt SMnCt
T
F I.1. /p411117ro
IL—
CO.IICL01 II11 1,/1 sn run
G
PIIs7(It PI/ IIITIK.
ARE
I
CM4 DI 5AI'1 FI.D
Model
Base
A
B
C
D
E
F
G
H
]
K
L
934
1194
445
19
10
53
187
101
159
495
520
4A7L5030N
4.3
(36-3/4)
(47)
(17-1/2)
(3/4)
1 (3/8)
(2-1/16)
(7-11/32)
(3-31/32)
(6-1/4)
(19-1/2)
(20-1/2)
SOUND POWER LEVEL
Model
A -Weighted Sound
Power Level [dB(A)]
Full Octave Sound Pourer [dB]
63 Hz
125 Hz
250 Hz
500 Hz
1000 Hz
2000 Hz
4000 Hz
8000 Hz
4A71_5030N
70
72
1 76
1 72
68
65
60
52
44
Note: Rated in accordance with AHRI Standard 270-Z008 `For reference only
MODEL
Sound Pressure [dB(A)]
aft
5ft loft
15ft
4A71.5030N
63
58
52
49
Note: Rated in accordance with AHRI Standard 275
2 4A7L5030N-SUB-1 B-EN
BUILT TO A HIGHER STANDARD'
A*lk6w S7imd d.
HEATING & AIR CONDITIONING
Product Specifications
OUTDOOR UNIT (a)(b)
4A7L5030N1XXXA
HIGH SPEED COOLING CAPACITY@
80/67-95(Btuh)
28200
POWER CONNS. - V/PH/HZ W
208/230/1/60
MIN. BIRCH. CIR. AAPACITY
15
BR. CIR. PROT. RTG. - MAX. (AMPS)
25
COMPRESSOR
DURATIONTM - SCROLL
NO. USED - NO. STAGES
1 - 1
VOLTS/PH/HZ
208/230/1/60
R.L. AMPS (a) - L.R. AMPS
11.7 - 71.3
FACTORY INSTALLED
START COMPONENTS W
NO (Uses BAYKSKT263)
INSULATION/SOUND BLANKET
NO
COMPRESSOR HEAT
NO
OUTDOOR FAN
PROPELLER
DIA. (IN.) - NO. USED
27.3 - 1
TYPE DRIVE - NO. SPEEDS
DIRECT- 1
CFM @ 0.0 IN. W.G. (0
2986
NO. MOTORS - HP
1-1/8
MOTOR SPEED R.P.M.
850
VOLTS/PH/HZ
200/230/1/60
F.L. AMPS
0.64
OUTDOOR COIL- TYPE
PLATE FIN
ROWS - F.P.I.
2 - 16
FACE AREA (SQ. FT.)
12.88
TUBE SIZE (IN.)
5/16
REFRIGERANT
LBS. - R-410A (O.D. UNIT) (e)
6 LBS., 9 OZ
FACTORY SUPPLIED
YES
LINE SIZE - IN. O.D. GAS (h)
3/4
LINE SIZE - IN. O.D. LIQ.
3/8
CHARGING SPECIFICATIONS
SUBCOOLING
8°F
DIMENSIONS
H X W X D
CRATED (IN.)
40.88 x 54.5 x 23
WEIGHT
SHIPPING (LBS.)
224
NET (LBS.)
197
.a) Certified in accordance with the Air -Source Unitary Air -conditioner
Equipment certification program, which is based on AHRI standard
210/240.
:b) Rated in accordance with AHRI standard 270.
0 Calculated in accordance with Nad. Elec. Codes. Use only HACR
circuit breakers or fuses.
'a) This value shown for compressor RLA on the unit nameplate and on
this specification sheet is used to compute minimum branch circuit
ampacity and max. fuse size. The value shown is the branch circuit
selection current.
'0 No means no start components. Yes means quick start kit
components.
0 Standard Air - Dry Coil - Outdoor
:9) This value approximate. For more precise value see unit nameplate.
;h) Max. linear length 150 ft.; Max. lift - Suction 50 ft.; Max. lift - Liquid
50 ft. For greater length consult refrigerant piping software Pub. No.
32-3312-0` (' denotes latest revision).
4A7L5030N-SUB-1 B-EN
BUILT TO A HIGHER STANDARD'
74*6" S7im&f d®
HEATING & AIR CONDITIONING
Mechanical Specification Options
General
The outdoor condensing units are factory charged with
the system charge required for the outdoor condensing
unit, ten (10) feet of tested connecting line, and the
smallest rated indoor evaporative coil match. This unit
is designed to operate at outdoor ambient
temperatures as high as 115°F. Cooling capacities are
matched with a wide selection of air handlers and
furnace coils that are AHRI certified. The unit is certified
to UL 1995. Exterior is designed for outdoor
application.
Casing
Unit casing is constructed of heavy gauge, galvanized
steel and painted with a weather -resistant powder
paint finish. The corner panels are prepainted. All
panels are subjected to our 1,000 hour salt spray test.
Refrigerant Controls
Refrigeration system controls include condenser fan,
compressor contactor and low and high pressure
switches. A factory supplied, field installed liquid line
drier is standard.
Compressor
The compressor features internal over temperature and
pressure protection. Other features include: Centrifugal
oil pump and low vibration and noise.
Condenser Coil
The outdoor coil provides low airflow resistance and
efficient heat transfer. The coil is protected on all four
sides by louvered panels.
Low Ambient Cooling
As manufactured, this system has a cooling capacity to
55°F. The addition of an evaporator defrost control
permits operation to 40°F. The addition of an
evaporator defrost control with TXV permits low
ambient cooling to 30°F.
The addition of the BAYLOAM107A low ambient kit
permits ambient cooling to 20°F.
Thermostats —Cooling only and heat/cooling (manual
and automatic change over). Sub -base to match
thermostat and locking thermostat cover.
4A71-5030N-SUB-1 B-EN
BUILT TO A HIGHER STANDARD'
A*lkea! S*gt*fd.
HEATING 6 AIR CONDITIONING
About American Standard Heating and Air Conditioning
American Standard has been creating comfortable and affordable living environments for more than a century. For
more information, please visit www.americanstandardair.com.
C (@ US
LISTED
The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to
using environmentally conscious print practices.
4A71.5030N-SUB-113-EN 07Feb2o24
Supersedes 4A7L5030N-SUB-tA-EN (October 2022) 12024 American Standard Heating and Air Conditioning
Submittal
Downflow
Two Stage Condensing
Gas Fired Furnace
60,000 BTU H
Downflow Only
S9X2B060D3PSBA
Note: Graphics in this document are for
representation only. Actual model may
differ in appearance.
TAG:
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
July 2019 S9X2B060D3-SUB-1 C-EN L#PIngersollRand.
I.INI/
1 rlun
t"IT
Downflow Furnace
IRLUT
AIR
111
B Size Cabinet
TI
�N
Iali
1.11,
1r 10::d
latdlll
11N -01
/tll
alct Y dm
,•u,
v a
,./111
I•IIIII
I.UI
,.11,
1.11111
same+ II»I
011/ r011
1011111
latdtll
141d»,
�R IKa Ilgl
{R/1
Ia b111
.0.
ar
/I•W
14idI11
A •
'
tT•IIIII
® N '
r1.11,
YI
d W Irli/III
11 11111
II
I.LII
),ILII
1•MI
If.l rl
I.Ir1
.O. 1.11,11
I I I.ILII
i� IT•1/II--�{ ..us
».IIII
vl-.•I
—
n,ra
I Iwl
II•I 16
luu
wOUT, LAY
++ AIR
I
rul m
n
Product Specifications
MODEL
S9X26060D3PSBA(a)
TYPE
Downflow
RATINGS (b)
1st Stage Input BTUH (ICS)
39,000
1st Stage Capacity BTUH
37,830
2nd Stage Input BTUH
60,000
2nd Stage Capacity BTUH (ICS) (0
(d)
58,200
1st Stage Temp. Rise (Min. -Max.)
25 - 55
2nd Stage Temp. Rise (Min. -Max.)
35 - 65
AFUE (%)
95.0
BLOWER DRIVE
DIRECT
Diameter — Width (In.)
11 X 8
No. Used
1
Speeds (No.) (e)
9
CFM vs. in. w.g.
See Fan Performance Table
Motor HP
1/2
RPM
1075
Volts/Ph/Hz
120 / 1 / 60
FLA
6.4
COMBUSTION FAN — Type
Centrifugal
Drive — No. Speeds
Direct - 2
Motor HP — RPM
3300/2600
Volts/Ph/Hz
120 / 1 / 60
FLA
0.66
FILTER — Furnished?
No
Type recommended
High Velocity
Hi Vel. (No.-Size-Thk.)
2 — 14x20 — 1 in.
VENT PIPE DIAMETER — Min
(in.) M(9)
2 Round
HEATEXCHANGER
MODEL
S9X2B060D3PSBA(a)
Type — Fired
409 Stainless Steel
— Unfired
29-4C Stainless Steel
Gauge (Fired)
20
ORIFICES — Main
Nat. Gas Qty. — Drill Size
3 - 45
LP Gas Qty. — Drill Size
3 - 56
GAS VALVE
Redundant - Two Stage
PILOT SAFETY DEVICE
Type
120 V SiNi Igniter
BURNERS — Type
Multiport Inshot
Number
3
POWER CONN. — V/Ph/Hz (h)
120 / 1 / 60
Ampacity (In Amps)
8.8
Max. Overcurrent Protection
' (Amps)
15
PIPE CONN. SIZE (in.)
1/2
DIMENSIONS
H x W x D
Uncrated (In.)
34 x 17-1/2 x 28-3/4
Crated (In.)
35-1/2 x 19-1/2 x 30-7/8
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
127/119
,) Meets Energy Star
o) For U.S. applications, above input ratings (BTUH) are up to 2,000
feet, derate 4% per 1,000 feet for elevations above 2,000 feet above
sea level. For Canadian applications, above input ratings (BTUH) are
up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500
feet above sea level.
c) Central Furnace heating designs are certified to ANSI Z21.47 / CSA
2.3.
d) Based on U.S. government standard tests.
,) 9 Speed constant torque ECM blower motor
n Refer to the Vent Length Table in the Installer's Guide.
.) All 59X2 furnace models have a vent outlet diameter that equals 2 in.
The above wiring specifications are in accordance with National
Electrical Code; however, installations must comply with local codes.
S9X2B060D3-SUB-1 C-EN
Airflow tables
Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.)
Model
Tap
0.1
0.3
0.5
0.7
0.9
i
i
SCFM
624
451
277
104
-
Watts
47
57
68
79
-
2
SCFM
866
734
602
470
338
Watts
89
102
116
129
142
3
SCFM
949
833
718
602
486
Watts
113
128
142
156
171
4
SCFM
1122
1025
928
831
733
Watts
165
182
200
217
235
S9XlB06OD3PSBA
5
SCFM
1178
1087
996
905
814
S9B1B060D3PSAA
191
209
227
246
264
S9X2B060D3PSBA
Watts
6
SCFM
1260
1180
1100
1021
941
Watts
233
252
271
290
309
7
SCFM
1370
1299
1228
1158
1087
Watts
296
316
336
355
375
8
SCFM
1480
1416
1352
1287
1223
Watts
365
387
408
429
450
9
SCFM
1504
1440
1376
1312
1249
Watts
384
406
427
449
470
S9X2B060D3-SUB-1 C-E N
CFM Versus Temperature Rise
Table 1. 2nd Stage Heating Table — Downflow
CFM VS. 2ND STAGE TEMPERATURE RISE
MODEL
800
900
1000 1100
1200
1300
1400
1500
1600
1700
1800
S9X2B060D3PSBA
60
54 49
45
41
38
36
Table 2. 1st Stage Heating Table — Downf low
CFM VS. 1ST STAGE TEMPERATURE RISE
MODEL
1000
1100
1200
1300
1400 ; 1500
1600
1700
1800
1900
2000 2100
S9X2B060D3PSBA
54
49
45
41
38 36
34
32
30
28
27 26
S9X2B060D3-SUB-1 C-EN
General Features
NATURAL GAS MODELS
Central Heating furnace designs are certified by the
American Gas Association for both natural and L.P.
gas. Limit setting and rating data were established and
approved under standard rating conditions using
American National Standards Institute standards.
SAFE OPERATION
The Integrated System Control is a solid state device
which continuously monitors for presence of flame
when the system is in the heating mode of operation.
Dual solenoid combination gas valve and regulator
provide additional safety.
QUICK HEATING
Durable, cycle tested, heavy gauge tubular stainless
steel primary heat exchanger quickly transfers heat
to provide warm conditioned air to the structure. Low
energy power vent blower, to increase efficiency and
provide a positive discharge of gas fumes to the
outside.
BURNERS
Multiport Inshot burners will give years of quiet and
efficient service. All models can be converted to L.P.
gas with LP conversion kit.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides
total control of furnace limit sensors, blowers, gas
valve, flame control and includes self diagnostics for
ease of service. Also contains dry contacts for EAC and
HUM.
ENERGY EFFICIENT OPERATION
Furnace is certified by the manufacturer to leak 1% or
less of nominal air conditioning CFM delivered when
pressurized to .5" water column with all inlets, outlets,
and drains sealed.
AIR DELIVERY
The variable speed blower motor has sufficient airflow
for most heating and cooling requirements and will
switch from heating to cooling speeds on demand from
room thermostat.
SECONDARY HEAT EXCHANGER
The S-Series furnace has a special type 29- 4C" •'
stainless steel secondary heat exchanger to reclaim
heat from flue gases which would normally be lost.
STYLING
Heavy gauge steel and "wrap -around" cabinet
construction is used in the cabinet with baked -on
enamel finish for strength and beauty. Every
orientation has at least two venting options. There are
no knockouts on cabinet.
FEATURES AND GENERAL OPERATION
The S-Series furnace utilizes a Silicon Nitride Hot
Surface Ignition system, which eliminates the waste of
a constant burning pilot. The integrated system control
lights the main burners upon a demand for heat from
the room thermostat. Complete front service access.
a. Low energy power venter
b. Vent proving pressure switches.
S9X26060D3-SUB-1 C-EN
Features and Benefits
UP TO 96.0% AFUE ON S9X2 FURNACE MODELS
Meets utility rebates
Lowers utility bills
ELECTRICALLY EFFICIENT
Efficient airflow design reduces electrical energy use
34 INCH TALL
Lighter, easier to move and fit into tight spaces like
short basements or tight closets
Works great with larger, high -efficiency coils
No knockouts
3—WAY MULTI -POISE / DEDICATED DOWNFLOW
11 SKU's — Upflow/ Horizontal Left; Horizontal Right
5 SKU's — Downflow
Added application flexibility and reduction in
specification errors
AIRFLOW
At least 400 CFM/ton at 0.5 in. H2O external static
pressure; setup airflow options down to 290 CFM/ton
REGULATORY
All models are air tight; 1% or less air leakage as per
ASHRAE 193
Open vestibule design provides a full 34" high open
vestibule
DIMENSIONS
Widths are industry standard: 17.5", 21 ", and 24.5"
Depth remains approximately 28"
Cabinet will be compatible with industry standard coils,
as well as, other accessories
INTEGRATED FURNACE CONTROL
Setup / Status / Diagnostics / Digital Display
No dip switches
Last six errors stored
Dry contact EAC and HUM connections
All Molex connections; no spade terminals
Low voltage labeled above and below
Rain shield over IFC keeps condensate off the control
TUBULAR STAINLESS STEEL PRIMARY HEAT
EXCHANGER
29-4C STAINLESS STEEL SECONDARY HEAT
EXCHANGER
Stainless steel is a more durable, corrosive -resistant
material than aluminumized steel
Integrated rail system for easy access if required
Reduces or eliminates need for baffles
VORTICA II BLOWER, DESIGNED EXCLUSIVELY
FOR THE S-SERIES FURNACE
Improved airflow efficiency
Durable, easy to clean, two piece housing
Single piece belly band/ motor arm assembly
Blower deck has full-length rails for easy removal and
replacement, regardless of poise
THREE—WAY MULTI -POISE (UPFLOW,
HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED
DOWNFLOW
Easier to specify
Shipped ready to install (no conversion kits required)
Every model has at least two venting options
When in horizontal, trap extends only about 2"
Barbed fitting on trap at hose connection and on
cabinet transition for hose has barbed fitting and
clamps at both ends for leak resistance.
Vent table improvements including longer vent
lengths; 2" pipe can be used up to 100K
S9X26060D3-SUB-IC-EN 7
Ingersoll Rand
Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient
environments. Our people and our family of brands —including Club Car`, Ingersoll Rand', Thermo King- and
Trane' —work together to enhance the quality and comfort of air in homes and buildings; transport and protect
food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a
world of sustainable progress and enduring results.
Ingersoll Rand. �T THERMO KING Adl_h.�� TI?WE'
ingersollrand.com
C(U)Us
Intertek
Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications
without notice.
We are committed to using environmentally conscious print practices.
S9X2B060D3-SUB-IC-EN 31 Jul2019
Supersedes SM2B060D3-SUB-I8-EN (July2016)
(LM16Ingersoll Rand