BLD2024-1015_Manufacturer_Specifications_and_Installation_Instructions_8.5.2024_11.41.04_AM_4421094TFTN 085-399 Installation and Operation Manual 2.0 SPECIFICATIONS Table 2-1 Specifications DESCRIPTION TFTN085 TFTN110 TFTN150 TFTN199 TFTN285 TFTN340 TFTN399 CSA Input Modulation [MBH] 1 8.5 - 85 11- 110 15 - 150 19.9 - 199 28.5 - 285 39.9 - 340 39.9 - 399 Heating Capacity [MBH] 1,2 79 101 138 184 263 324 380 Net AHRI Rating, Water 69 88 120 160 229 282 330 [MBH] 1,2 AFUE [%] z 96 95 95 95 95 95.4 95.4 Water Connections, NPT 1-1/4 (M) 1-1/4 (M) 1-1/4 (M) 1-1/4 (M) 1-1/4 (M) 1-1/2 (M) 1-1/2 (M) [in.] Gas Connection, NPT [in.] % (M) 3/ (M) % (M) % (M) % (M) 3/ (M) % (M) Vent/Air-inlet Pipe Diameter 2 or 3 2 or 3 2 or 3 2 or 3 3 4 4 [in.] 3 Cabinet Height [in.] 34-1/8 34-1/8 34-1/8 34-1/8 34-1/8 36-1/2 36-1/2 Cabinet Width [in.] 19-7/8 19-7/8 19-7/8 19-7/8 21-3/8 25-1/4 25-1/4 Cabinet Depth [in.] 17-1/4 17-1/4 18-3/4 18-3/4 18-3/8 18-7/8 21-1/4 Approx. Boiler Weight 107 107 122 140 180 250 250 with Water [lbs] Approx. Boiler Water 1.4 1.4 2.0 2.8 4.9 7.1 6.4 Content [Gallons] Electrical Rating 120V / 1Ph / 60Hz / less than 12A Notes: 1. Listed Input and Output ratings are at minimum vent lengths at an altitude of 0-2000ft. Numbers will be lower with longer venting and/or altitudes greater then 2000ft. 2. Ratings based on standard test procedures prescribed by the U.S. Department of Energy; certified by AHRI. Efficiency listed for models TFTN340 & TFTN399 represents Thermal Efficiency (AFUE is not applicable). 3. TFTN units require a special venting system, use only vent materials and methods detailed in these instructions. 2.1 High Altitude Operation The TFTN is designed to operate at its maximum listed capacity in installations located at 0-2000ft above Sea Level. Since the density of air decreases as elevation increases, maximum specified capacity should be de -rated for elevations above 2000 ft [610 m] in accordance with Table 2-2. Table 2-2 De -rate %for High Altitudes Elevations 2001 ft. 3000 ft. 4000 ft. 4500 ft. 5000 ft. In Canada 1 de -rate by 10% de -rate by 10% de -rate by 10% de -rate by 10% de -rate % may vary In USA z - de -rate by 12% de -rate by 16% de -rate by 18% de -rate by 20% Notes: 1 Canada: Altitudes between 2000-4500 ft., de -rate by 10%. Consult local authorities for de -rating capacities for altitudes above 4500 ft. z USA: De -rate capacity by 4% for every 1000 ft [305 m], if altitude is above 2000 ft. Combustion — At elevations above 2000 feet, the combustion of the boiler must be checked with a calibrated combustion analyzer to ensure safe and reliable operation. It is the Installers responsibility to check the combustion and to adjust the combustion in accordance with section 9.0 GAS VALVE AND BURNER SET-UP. Failure to follow these instructions may result in property damage, serious injury, or death. 7