BLD2024-1074_Manufacturer_Specifications_and_Installation_Instructions_8.15.2024_5.26.26_PM_4444344MITSUBISHI
ELECTRIC
COOLING & HEATING
M-SERIES & P-SERIES
Pocket Reference Guide
mitsubishipro.com
MAKE COMFORT Per" ggal
® 2015 Mitsubishi Ele tnc US, Inc. I Form No. MORO 10.20151 REVISED
MITSUBISHI
/_ ELECTRIC
COOLING & HEATING
✓
Pre -visit Checklist
Verify appointment
✓
Call 30 minutes before you arrive
✓
Verify equipment in stock at distributor
✓
Credit application/financing options
✓
Local rebate information
Bring this booklet along so you have
product information and the contact
phone numbers below handy
Customer Care: 800-433-4822
www.mitsubishipro.com
Advanced Technology.
Superior Comfort.
Split -zoning is the most popular type of air-conditioning
technology in the world. Mitsubishi Electric takes
split -zoning to a new level —our cooling and heating
systems deliver year-round personal comfort even in the
harshest of climates.
Mitsubishi Electric single- and
multi -split systems also feature:
Exceptional cooling and heating performance.
. Automatic cool/heat changeover.
Maximum energy efficiency with higher SEER
and HSPF ratings.
Easy installation.
Environmentally friendly R410A refrigerant.
Convenient temperature, fan, and airflow control.
. Advanced filtration to help provide high air quality.
. Whisper -quiet operation.
M-Series components are up to
83% recyclable
M-Series was green before
green was cool.
ENERGY STAR°
Mitsubishi Electric systems are now more
environmentally friendly than ever!
Use them to earn many available state, municipal, and utility rebates.
M-Series Qualifying Models*
MUY-GE09NA & MSY-GE09NA-9
MUY-GE09NA2 & MSY-GE09NA-9
MUY-GE12NA & MSY-GEI2NA-9
MUY-GE12NA2 & MSY-GE12NA -9
MUY-GEI5NA-1 & MSY-GEI5NA-9
MUY-GE15NA2 & MSY-GEI5NA-9
MUY-GE24NA & MSY-GE24NA
MUZ-FE09NA-1 & MSZ-FE09NA-8
MUZ-FE12NA1 & MSZ-FEI2NA-8
MUZ-FE18NA & MSZ-FE18NA
MUZ-FH09NA & MSZ-FH09NA
MUZ-FH12NA & MSZ-FH12NA
MUZ-FH15NA & MSZ-FH15NA
MUZ-FH18NA & MSZ-FH18NA
MUZ-GE09NA2 & MSZ-GE09NA-9
MUZ-GE12NA2 & MSZ-GEI2NA-9
MUZ-GE15NA2 & MSZ-GEI5NA-9
MUZ-GEI5NA-1 & MSZ-GEI5NA-9
MUZ-GE09NA & MSZ-GE09NA-9
MUZ-GE12NA & MSZ-GEI2NA-9
MUZ-GE24NA & MSZ-GE24NA
SUZ-KA09NA & SEZ-KD09NA4
SUZ-KAl2NA & SEZ-KD12NA4
SUZ-KA15NA & SEZ-KD15NA4
SUZ-KA18NA & SEZ-KD18NA4
SUZ-KA09NA & SLZ-KA09NA4
SUZ-KAl2NA & SLZ-KAl2NA4
MXZ-2B20NA-1 w/ Non -Ducted Indoor Units
'ENERGY STAR certified model as of print time
M-Series Qualifying Models*
MXZ-21320i w/ Specific (reference AHRI Directory)
MXZ-21 w/ Non -Ducted Indoor Units
MXZ-21 w/ Mixed Ducted and Non -Ducted Indoor Units
MXZ-3C24NA w/ Non -Ducted Indoor Units
MXZ-31 w/ Specific (reference AHRI Directory)
MXZ-31 w/ Non -Ducted Indoor Units
MXZ-31 w/ Non -Ducted Indoor Units
MXZ-31 w/ Mixed Non -Ducted and Ducted Indoor Units
MXZ-3C30NAHZ w/ Non -Ducted Indoor Units
MXZ-4C36NAHZ w/ Non -Ducted Indoor Units
MXZ-4C36NAHZ w/ Mixed Non -Ducted and Ducted Indoor Units
MXZ-5C42NAHZ w/ Non -Ducted Indoor Units
MXZ-5C42NAHZ w/ Mixed Non -Ducted and Ducted Indoor Units
MXZ-8C48NA w/ Non -Ducted Indoor Units
MXZ-8C48NAHZ w/ Non -Ducted Indoor Units
P-Series Qualifying Models*
PUZ-HA30NHA4 & PCA-A30KA6
PUZ-HA30NHA4 & PEAD-A30AA5
PUZ-HA30NHA4 & PKA-A30KA6
PUZ-HA30NHA4 & PLA-A30BA6
PUZ-HA30NHA4 & PVA-A30AA4
PUZ-HA36NHA4 & PCA-A36KA6
PUZ-HA361 & (x2) PEA-A18AA6
PUZ-HA361 & PEAD-A36AA5
PUZ-HA36NHA4 & PKA-A36KA6
PUZ-HA361 & PLA-A36BA6
PUZ-HA361 & PVA-A36AA44
For tax credit details and forms
visit www.mitsubishicomfort.com/taxcredit
For details on state and utility rebates
visit www.dsireusa.org
`ENERGY STAR certified model as of print time
Features & Benefits
How to Read a Model Number
MXZ- 2C 20NA-1
M —Mini-split MODEL VERSION
S = Mini -split WIRING METHOD
TYPE A = A Control
S = Wall -mounted indoor unit
E = Horizontal -ducted indoor unit COMPRESSOR
U = Single -system outdoor unit VOLTAGE
X = Mufti -system Outdoor unit
F = Floor -mounted unit W = 115V Compressor
L = Ceiling -recessed indoor unit N = 230V Compressor
V = Multi -position AHU
CAPACITY (nominal)
COOLING ONLY /HEAT PUMP In Btu/h (x 1,000)
Y = Cooling only (INVERTER)
Z = Heat pump INVERTER) SYSTEM
GENERATION
NUMBER OF ZONES
2 = Max. number of zones
M-Series (9,000 - 48,000 Btl
1. Designed for residential applications.
2. User-friendly zoned cooling and heating solutions for
single- or multi -room applications or the whole home.
3. Hyper -Heating INVERTERTM (H2i®) outdoor units can
provide high heating performance at lower ambient
temperatures.
4. Many ENERGY STAR® certified models.
4
How to Read a Model Number
PKA-A24KA 4-13S
FAMILY T
P = Professional
BS =Seacoast protection
pkg. for outdoor unit
TYPE
K = Wall -mounted indoor unit
MODEL VERSION
C = Ceiling -suspended indoor unit
L = Ceiling -recessed indoor unit
E = Horizontal -ducted indoor unit
SYSTEM CONTROLS
U = Single system outdoor unit
GENERATION
V = MulliPosition AHU
COOLING ONLY / HEAT PUMP
Y = Cooling only (INVERTER -driven)
CAPACITY (nominal)
Z = Heat pump (INVERTER -driven)
In Btu/h (x 1,000)
A = Both heating and cooling
GENERATION
A = Generation A
HA = Hyper -heating INVERTER unit
1. For light commercial, industrial, or institutional
installations- ideal for applications requiring year-round,
low ambient cooling such as computer, elevator and
equipment rooms.
2. Hyper -Heating INVERTERTM (1-12M) outdoor units can
provide superior heating performance at lower ambient
temperatures.
3. Long lineset lengths.
4. Outside air intake on PLA, PCA PEND and PVA models.
M-Series Models
Our standard line is now greener than ever!
GE Models
► Eight ENERGY STAR® models. aOOO
P."Smart Set' programming button jwith SETBACK down to 501 F in - 22,500 Btulh)
heating (9,000 - 18,000 only).
► Washable 10- ear catechin filter See pares and 1
Y for more information.
mation..
and anti -allergy enzyme filter.
► Cooling -only and heat pump models.
P. Five fan speeds plus AUTO (Select Models).
► As quiet as 19 dB(A).
D Models
(30,700 - 34,600 Btu/h)
Wide vane mode for precise directional airflow (also available
on MSY/Z-GE24NA).
Powerful mode for quick 15 minute heating/cooling boost (also
available on MSY/Z-GE24NA).
Cooling -only and heat pump models.
- 150"-
With the WIDE VANE or SWING mode, available on the MSYQ-GE24/
D30/36NA there is an option for seven horizontal airflow directions that
provide 150' of airflow for greater conditioned air circulation.
High -efficiency, Hyper -heating systems
FE & FH ModelsArm
► 30.5 - 22.0 SEER, 13.5 - 12.0
HSPF, INVERTER -driven
compressor.
► Quiet operation as low as 20 dB(A). (9,000 - 18,000 Btulh)
► Hyper -heating performance down See page is for more information,
to minus 13' F outdoor ambient.
► 100% heating capacity at 5° F outdoor ambient.
P. Quiet operation as low as 20 dB(A).
► Triple -action filtration.
• Nano -platinum filter.
• Electrostatic anti -allergen enzyme filter.
• Deodorizing filter.
► Energy saving mode.
P. Double -vane air delivery for enhanced circulation.
• Option to set each vane separately.
• Indirect or direct setting option.
• Natural flow setting that creates air movement like
a natural breeze.
P. i-see SensorTm 3D.
• Infrared human sensing technologies to measure location of
human heat signatures.
• Senses floor temperature in order to deliver conditioned air to
those areas that need it using double -vane airflow and motorized
vertical vanes.
► NEW multi -function hand-held wireless controller or wall -mounted
wireless controller available with smart phone control capabilities.
MFZ Models �!
P. Ideal for low -wall mounted applications.
► Bi-directional airflow (top and
bottom discharge).
► "Smart Set' programming button with
SETBACK down to 500 F in heating. ( _ P18,OOO Btulh)
► Washable, 10-year catechin filter and See page 19 for
anti -allergy enzyme filter. more information.
► For use with MXZ multi -zone outdoor units only. 7
M-Series Models
i
SEZ Models
. Small compact design (7-7/8" height). - to
► Adjustable static pressure.
► Built-in condensate lift mechanism (22-1/2" lift).
► Rear return or bottom return (with optional accessory).
► Low operating sound pressure levels; as low as 23 dB(A).
► All four ENERGY STAR® certified models.
See pages 20-21 for more information.
SLZ Models
► Fits in 2x2 suspended ceiling grid.
► 4-way airflow.
► Built-in condensate lift mechanism
(19-11/16" lift).
► Catechin deodorizing filter.
P. Two ENERGY STAR® rated models.
► Outside air intake.
MVZ Models
► Performance: One inch foam R4.2,
fiberglass -free insulation reduces
condensation and boosts efficiency.
► Quality: durable, powder coated cabinet.
► Serviceability: easily removable fan
provides access for coil cleaning. (12,000 - 40,000 Btu/h)
► Flexibility: true multi -position, requiring no Seepages 18-19for
additional kits for downflow configuration. more information.
► Installation: quality construction with disassemblyin mind to make
fitting through tight access points simple.
► Comfort: DC motor ensures quiet and efficient operation year round.
► Low Impact: Fully RoHS compliant to reduce carbon footprint.
► Air Quality: Positively pressurized cabinet and
tested air leakage less than 1 %.
► For use with MXZ Multi -zone outdoor units only.
8
MXZ Multi -zone Heat Pumps
2:1, 3:1, 4:1, 5:1, and 8:1 Zoned Solutions
(20,000-48,000 Btulh)
► Many combinations have received
the ENERGY STAR® certification.
► Precise, individual room
comfort control.
► Multiple indoor air handler
options (non -ducted and ducted).
► Minimum of two indoor units must
be installed.
MSZ-FH09 -18NA
MSZ-GE06-24NA
10
PLA-Al2-3613A
LI
(for use with MXZ only)
• 1.
SEZ-KDO
PEAD-A24-36AA5
STANDARD:
H21:
MXZ -2B20NA-1
MXZ-2C20NAHZ
MXZ-3C24NA
MXZ-3C24NAHZ
MXZ-3C30NA
MXZ-303ONAHZ
MXZ-4C36NA
MXZ-4C36NAHZ
MXZ-5C42NA
MXZ-5C42NAHZ
MXZ-8C48NA
MXZ-8C48NAHZ
mom
MVZ-Al2-36AA4
(for use with MXZ only)
Seepages 18-19 for more information.
M-Series Models
DIAMOND OCOM FORT SYSTEW
r.
N
Outdoor Unit
HORIZONTAL -DUCTED
INDOOR UNITS
FLOOR -MOUNTED
INDOOR UNITS
'Illustration purposes only. Refer to compatibility
chart for combination allowances.
10
Multi -zone Systems*
INDOOR UNITS
MULTI -POSITION DUCTED
AIR HANDLER
INDOOR UNITS
M-Series Cooling -only Systems
M SY
Model Specifications
(air conditioners)
Indoor Model #
Outdoor Model #
Rated Cooling Capacity (Btu/h)
r
11
Mi
®■
9,000 12,000
Cooling Capacity Range (Btu/h)
3,800-12,200
3,800-13,600
SEER
23.2
22.7
Lineset Size (Liquid x Gas)
1/4" x 3/8"
1/4" x 3/8"
Lineset Length/Height Max. Separation
65740'
65740'
Breaker Size
15AMP
15AMP
Test conditions are based on AHRI 210/240.
12
MUY-GE15NA-2
MSY-GE15NA-9
14,000 17,200 22,500 30,700 34,600
3,100-18,200
3,700-18,700
8,200-31,400
9,800-30,700
9,800-34,600
21.6
19.2
19
16
15.1
1/4" x 1/2"
1/4" x 1/2"
3/8" x 5/8"
3/8" x 5/8"
3/8" x 5/8"
65740'
100750'
100750'
1001/50,
100'/50'
15AMP
15AMP
20AMP
25AMP
25AMP
M-Series units are pre -charged for up to a 25' line set.
13
M-Series Heat Pump Systems
MSZ/MUZ H2i®
Model Specifications
(heat pumps)
A 11, A I
Indoor Model #
Outdoor Model #
Rated Cooling Capacity (Btu/h)
r
MUZ-FHO9NA
9,000
12,000
.
Cooling Capacity Range(Btu/h)
1,700-12,000
2,500-13,600
Heating Capacity Range at 47T (Btu/h)
1,600 - 18,000
3,700 - 21,000
Max. Heating Capacity at 17T (Btu/h)
12,200
13,600
Max. Heating Capacity at 5°F (Btu/h)
10,900
13,600
SEER/HSPF
30.5/13.5
26.1/12.5
Lineset Size (Liquid x Gas)
1 /4" x 3/8"
Lineset Length/Height Max. Separation
65740'
65740'
Breaker Size
15 AMP
15 AMP
Test conditions are based on AHRI 210/240.
14
0" 1
MSZ-FH09NA
A111 I111
15,000
17,200
6,450 - 19,000
6,450 - 21,000
5,150 - 24,000
5,150 - 30,000
18,000
20,300
18,000
20,300
22.0/12.0
21.0/12.0
1 /4" x 1 /2"
1001/50,
1001/50,
20AMP
20AMP
15
M-Series Heat Pump Systems
MSZ/MUZ
Model Specifications
(heat pumps)
Indoor Model #
r
®®®.
9,000
12,000
14,000
Outdoor Model #
Rated Cooling
Capacity (Btu/h)
Cooling Capacity
Range(Btu/h)
3,800-
12,200
3,800-
13,600
3,100-
18,200
Heating Capacity Range at
47° F (Btu/h)
4,500-
14,100
5,500-
18,100
4,800-
20,900
Max. Heating Capacity at
17' F (Btu/h)
8,700
11,200
15,900
Max. Heating Capacity at
5° F (Btu/h)
7,061
9,194
13,022
SEER/HSPF
23.2/11
22.7/11.4
21.6/11.2
Lineset Size (Liquid x Gas)
1/4" x 3/8"
1/4" x 3/8"
1/4" x 1/2"
Lineset Length/ Height Max.
Separation
65740'
65740'
65740'
Breaker Size
15AMP
15AMP
15AMP
Test conditions are based on AHRI 210/240.
16
MSZ-GE09NA-9
MUZ-GE09NA2
.®®
MSZ-GE1 8NA-9
17,200
=
22,500
MSZ-D30NA-8
MUZ-D30NA-1
30,700
MSZ-D36NA-8
33,200
3,700-
18,700
8,200-
31,400
9,800-
30,700
9,800-
33,200
3,500-
25,200
7,500-
36,900
8,700-
34,000
8,700-
36,000
17,200
24,600
20,800
22,800
13,562
21,160
16,305
19,090
19.2/10
19/10
14.5/8.2
14.5/8.2
1/4" x 1/2"
3/8" x 5/8"
3/8" x 5/8"
3/8" x 5/8"
100750'
1001/50,
1001/50,
1001/50,
15AMP
20AMP
25AMP
25AMP
MSZ-GE24NA and MSZ-FH18NA precharged to 33' line set
17
M-Series Heat Pump Systems
MVZ and MFZ for MXZ-C
Model Specifications
(heat pumps)
Indoor Model #
®®®,
Outdoor Unit
Rated Cooling
Capacity (Btu/h)
9,000 12,000 18,000
Rated Heating
Capacity at 47' F
10,900
14,400
21,600
(Btu/h)
Airflow at Cooling/
Heating(SH-H-M-L)
169-205-251-314 163-
177-215-261-321
251-279-325-394
(H-M-L) (CFM)
197-241-303
170-207-252-309
241-269-313-379
ESP (In. W.G.)
Sound at Cooling/
Heating Heatin)(dB�)
40-35-30-25
41-36-31-26
46-42-38-35
40-35-30-25
41-36-31-26
47-42-38-35
Lineset Size
(Liquid x Gas)
3/8" x 1/4"
3/8" x 1/4"
1/2" x 1/4"
Breaker Size
25AMP
25AMP
25AMP
Test conditions are based on AHRI 210/240.
18
MVZ-Al2AA4
12,000 18,000 24,000 30,000
36,000
13,500
20,000 27,000 34,000
40,000
400-340-280
400-340-280
585-497-410 735-625-515 875-744-613
585-497-410 735-625-515 875-744-613
1095-931-767
1095-931-767
0.30-0.50-0.80
35-31-27
35-31-27
36-32-36
36-32-36
38-34-30
38-34-30
40-36-21
40-36-21
43-39-35
43-39-35
1/4" x 3/8"
1/4" x 3/8"
1/4" x 1/2"
1/4" x 1/2"
3/8" x 5/8"
15AMP
15AMP
15AMP
15AMP
20AMP
19
SEZ/SLZ System Specifications
(heat pumps)
SEZ-KD15NA4
SUZ-KA15NA
Indoor Model #
r
r
r
Outdoor Model #
• r •
8,100
®®-
11,500
14,100
Rated Cooling Capacity (Btu/h)
Cooling Capacity Range(Btu/h)
3,8010-10,900
3,800-13,300
3,800-17,000
Heating Capacity Range at 47' F
(Btu/h)
q,g00-14,100
4,800-16,400
4,800-21,100
Heating Capacity at 170 F (Btu/h)
6,700
9,000
11,900
SEER/HSPF
15/10
16/10
15.5/10
Lineset Size (Liquid x Gas)
1/4" x 3/8"
1/4" x 3/8"
1/4" x 1/2"
Lineset Length/Height Max. Separation
65740'
65740'
65740'
Breaker Size (MOCP)
15AMP
15AMP
15AMP
Test conditions are based on AHRI 210/240.
20
Pee
SLZ-KA15NA W,,,
Ordered separately
V v v i=�
LINK%
Wireless Technology
MHK1
17,200 8,400
11,100 15,000
3,800-19,000
3,100-10,900
3,400-13,300
3,800-17,700
4,800-24,900
3,100-14,100
3,100-17,100
3,100-22,200
13,100
6,200
8,300
12,000
17.5/10
15/9.6
15.4/9.6
16/9.6
1/4" x 1/2"
1/4" x 3/8"
1/4" x 3/8"
1/4" x 1/2"
1001/50,
65740'
65740'
65740'
15AMP
15AMP
15AMP
15AMP
21
MXZ Series
MXZ-C
Model Specifications
(multi -zone heat pumps)
Outdoor Model #
Rated Cooling Capacity(Btu/h)
r
18,000 22,000
Cooling Capacity Range(Btu/h)
7,800-20,000
12,600-25,500
Heating Capacity Range at 47° F (Btu/h)
8,500-25,500
11,400-30,600
Heating Capacity at 17' F (Btu/h)
12,500
14,000
Individual/Combined Max. Lineset Length
827164'
827230'
Max. Vertical Separation
49'*/33'
49'*/49'
Breaker Size
20AMP
20AMP
SEER/HSPF
non -ducted
18.00/8.90
20.00/9.80
SEER/HSPF mixed
16.75/8.70
18.00/9.50
SEER/HSPF ducted
15.50/8.50
16.00/9.20
Test conditions are based on AHRI 210/240.
See page 3 for ENERGY STAR® certified combinations.
Refer to submittal document for combination performance.
** 131' applies when outdoor unit is installed below indoor unit.
22
Each MXrequires
least branch branch box
at onere with
a maximum of two.
Two sizes are available:
3-branch (PACBC)
and 5-branch
BRANCH BOX
(Phown
FOR INDOOR UNIT
shown above).
above).
CONNECTIONS
MXZ-8C48NA
28,400
35,400
40,800
48,000
12,600-28,400
12,600-36,400
6,000-43,000
6,000-48000
11,400-36,000
11,400-43,000
7,200-53,600
7,200-54,000
16,000
22,200
24,400
36,600
82'/230'
827230'
827230'
2627492'
49'*/49'
49'*/49'
49'*/49'
131'**/164'
20AMP
25AMP
40AMP
50AMP
19.00/10.60
19.20/11.00
19.70/10.30
18.90/11.40
17.60/10.10
17.45/10.40
17.45/9.70
16.80/10.75
16.20/9.60
16.00/9.80
15.20/9.10
14.70/10.10
SEE PAGE 26 FOR INDOOR UNIT CONNECTION CAPABILITIES.
See section 5 of installation manual for full details on MXZ-8C48NA
refrigeration piping lengths. 23
MXZ Series
MXZ-C H2i®
Model Specifications
(multi -zone heat pumps)
I Ilr / Ilr
Outdoor Model #
Rated Cooling Capacity(Btu/h)
r
18,000
22,000
Cooling Capacity Range(Btu/h)
6,000-20,000
6,000-23,600
Heating Capacity Range at 47o F (Btu/h)
7,400-25,500
7,200-30,600
Max. Heating Capacity at 17o F (Btu/h)
22,000
25,000
Max. Heating Capacity at 5° F (Btu/h)
22,000
25,000
Individual/Combined Max. Lineset Length
82'/164'
82'/230'
Max. Vertical Separation
49'
49'
Breaker Size
40 AMP
40 AMP
SEER/HSPF
non -ducted
17.00/9.80
19.00/10.00
SEER/HSPF mixed
16.00/9.65
17.25/9.50
SEER/HSPF ducted
15.00/9.50
15.50/9.00
Test conditions are based on AHRI 210/240.
See page 3 for ENERGY STAR® certified combinations.
Refer to submittal document for combination performance.
** 131' applies when outdoor unit is installed below indoor unit.
24
Each MX7—H2i® requires at
least one branch box with
a maximum of two.
Two sizes are available:
3-branch (PAC-AKA30BC) and
BRANCH BOX
5-branch
FOR INDOOR UNIT
(PAC-AKA50BC,
CONNECTIONS
shown above).
MV-8C48NA
I Ilr
/ Ilr / 117 Ally
28,400
36,000
42,000
48,000
6,000- 28,400
6,000- 36,000
6,000-4 2,000
6,000-4 8,000
7,200-36,000
7,200-45,000
7,200-48,000
7,200-54,000
28,600
45,000
48,000
54,000
28,600
45,000
48,000
54,000
827230'
2627492'
2627492'
2627492'
49'*/49'
131'**/164'
131'**/164'
131'**/164'
40AMP
50AMP
50AMP
50AMP
18.00/11.00
19.10/11.30
19.00/11.00
18.90/11.00
17.00/10.40
17.45/10.70
17.00/10.55
16.80/10.50
16.00/9.80
15.80/10.70
15.00/10.10
14.70/10.00
SEE PAGE 28 FOR INDOOR UNIT CONNECTION CAPABILITIES.
See section 5 of installation manual for full details on refrigeration piping lengths.
25
MXZ-Series Port Adapters
PORT ADAPTER GUIDE
Available Indoor Units Line Set Size
MSZ Wall -mounted
MSZ-GEO6NA-9
3/8" gas x 1/4" liquid
MSZ-GE09NA-9
3/8" gas x 1/4" liquid
MSZ-GEI2NA-9
3/8" gas x 1/4" liquid
MSZ-GEI5NA-9
1/2" gas x 1/4" liquid
MSZ-GEI8NA-9
1/2" gas x 1/4" liquid
MSZ-GE24NA
5/8" gas x 3/8" liquid
MSZ-FE09NA-8
3/8" gas x 1/4" liquid
MSZ-FEI2NA-8
3/8" gas x 1/4" liquid
MSZ-FE18NA
5/8" gas x 3/8" liquid
MSZ-FH09NA
3/8" gas x 1/4" liquid
MSZ-FH12NA
3/8" gas x 1/4" liquid
MSZ-FH15NA
1/2" gas x 1/4" liquid
MSZ-FH18NA
1/2" gas x 1/4" liquid
MFZ Floor -standing
MFZ-KA09NA
3/8" gas x 1/4" liquid
MFZ-KAl2NA
3/8" gas x 1/4" liquid
MFZ-KA18NA
1/2" gas x 1/4" liquid
MVZ Multi -position
MVZ-Al2AA4
1/2" gas x 1/4" liquid
MVZ-Al8AA4
1/2" gas x 1/4" liquid
MVZ-A24AA4
5/8" gas x 3/8" liquid
MVZ-A30AA4
5/8" gas x 3/8" liquid
MVZ-A36AA4
5/8" gas x 3/8" liquid
26
Available Indoor Units Line Set Size
PLA Ceiling -recessed
PLA-Al2BA6 1/2" gas x 1/4" liquid
PLA-Al8BA6
1/2" gas x 1/4" liquid
PLA-A24BA6
5/8" gas x 3/8" liquid
PLA-A30BA6
5/8" gas x 3/8" liquid
PLA-A36BA6
5/8" gas x 3/8" liquid
PLA-A42BA6
5/8" gas x 3/8" liquid
PCA Ceiling -suspended
PCA-A24KA6
5/8" gas x 3/8" liquid
SLZ Ceiling -recessed
SLZ-KA09NA
3/8" gas x 1/4" liquid
SLZ-KAl2NA
3/8" gas x 1/4" liquid
SLZ-KA15NA
1/2" gas x 1/4" liquid
SEZ/PEAD Horizontal -ducted
SEZ-KD09NA4
3/8" gas x 1/4" liquid
SEZ-KD12NA4
3/8" gas x 1/4" liquid
SEZ-KD15NA4
1/2" gas x 1/4" liquid
SEZ-018NA4
1/2" gas x 1/4" liquid
PEAD-A24AA4
5/8" gas x 3/8" liquid
PEAD-A30AA4
5/8" gas x 3/8" liquid
PEAD-A36AA4
5/8" gas x 3/8" liquid
PORT ADAPTERS PART NUMBERS
MAC-A454JP-E
3/8" x 1/2"
MAC-A455JP-E
1/2" x 3/8"
MAC-A456JP-E
1/2" x 5/8"
PAC-SG76RJ-E
3/8" x 5/8"
PAC-493PL
1/4" x 3/8"
27
MXZ-Series Port Adapters
PORT ADAPTER GUIDE
MXZ-2B20NA-1
MXZ-3C24NA
MXZ-3C30NA
MXZ-4C36NA
MXZ-5C42NA
i
MXZ-8C48NA
MXZ-2C20NAHZ
MXZ-3C24NAHZ
MXZ-3C30NAHZ
MXZ-4C36NAHZ
MXZ-5C42NAHZ
MXZ-8C48NAHZ
28
The following MXZ units must
utilize at least one branch box
MXZ-8C48NA
MXZ-4036NAHZ
MXZ-5C42NAHZ
MXZ-8048NAHZ
Branch Boxes
Port
Gas
1:
Liquid
A; B; C
3/8"
1:
1/4"
A; B; C; D
3/8"
1/4"
E
1/2"
1/4"
Notes for application:
• Check the lineset sizes for your indoor selected models.
• Select the branch box or boxes needed for
your application.
• Compare indoor unit lineset sizes to branch box or
outdoor unit port sizes.
• Connect 15K + indoor units to the larger 1/2" port on
the PAC-AKA50BC branch box or outdoor unit.
• Adapt lineset size with appropriate port adapter from
above list.
• When using the PLA-A24BA6, PEAD-A24AA5, PEAD-
A30AA5, PEAD-A36AA5, MSZ-GE24NA two port adapters
will be needed 1-MAC-A456JP-E (1/2" x 5/8") or
1-PAC-SG76RJ-E (3/8" x 5/8") and 1 - PAC-493PI
(1/4" x 3/8").
29
M-Series Correction Factors
Cooling Capacity Correction Factors
MUZ-GE09NA2
MUZ-GE12NA2
Capacity x 1.0 Capacity x 0.954
MUZ-GE15NA2
MUZ-GEI8NA-1
Capacity x 0.878 -
MUZ-GE24NA
Capacity x 1.0
Capacity x 0.954
Capacity x 0.878
Capacity x 0.771
MUZ-D30NA-1
Capacity x 1.0
Capacity x 0.95
Capacity x 0.878
Capacity x 0.713
MUZ-D36NA-1
MUY-GE09NA2
Capacity x 1.0
Capacity x 0.954
Capacity x 0.878
-
MUY-GE12NA2
MUY-GE15NA2
MUY-GEI8NA-1
MUY-GE24NA
Capacity x 1.0
Capacity x 0.954
Capacity x 0.878
Capacity x 0.771
MUY-D30NA-1
Capacity x 1.0
Capacity x 0.95
Capacity x 0.878
Capacity x 0.713
MUY-D36NA-1
MUZ-FE09NA-1
Capacity x 1.0
Capacity x 0.945
Capacity x 0.878
-
MUZ-FEI2NA-1
MUZ-FE18NA
Capacity x 1.0
Capacity x 0.945
Capacity x 0.878
Capacity x 0.771
MUZ-FH09NA
Capacity x 1.0
Capacity x 0.945
Capacity x 0.878
-
MUZ-FH12NA
MUZ-FH15NA
Capacity x 1.0
Capacity x 0.945
Capacity x 0.878
Capacity x 0.771
MUZ-FH18NA
SUZ-KA09NA
Capacity x 1.0
Capacity x 0.954
Capacity x 0.878
-
SUZ-KAl2NA
SUZ-KA15NA
SUZ-KA18NA
30
M-Series Air Outlet Coverage Range*
Model
Mode
MSZ-GEO6NA-9
MSY-GE09NA-9
MSZ-GE09NA-9
MSY-GEI2NA-9
MSZ-GEI2NA-9
HEAT
DRY
406
29.5
COOL
WET
286
21.0
MSY-GEI5NA-9
MSZ-GEI5NA-9
HEAT
DRY
463
33.5
COOL
WET
385
28.0
MSY-GEI8NA-9
MSZ-GEI8NA-9
HEAT
DRY
512
36.9
COOL
WET
385
28.0
MSY-GE24NA
MSZ-GE24NA
HEAT
DRY
738
36.9
COOL
WET
661
33.2
MSY-D30NA-8
MSZ-D30NA-8
MSY-D36NA-8
MSZ-D36NA-8
HEAT
DRY
848
45.0
COOL
WET
763
40.7
MSZ-FE09NA-8
HEAT
DRY
381
27.7
COOL
WET
307
22.4
MSZ-FEI2NA-8
HEAT
DRY
420
30.4
COOL
WET
350
25.4
MSZ-FE18NA
HEAT
DRY
738
36.9
COOL
WET
661
33.2
MSZ-FH09NA
HEAT
DRY
437
29.8
COOL
WET
328
22.5
MSZ-FH12NA
HEAT
DRY
454
31.0
COOL
WET
342
23.5
MSZ-FH15NA
HEAT
DRY
497
33.8
COOL
WET
354
24.1
MSZ-FH18NA
HEAT
DRY
514
23.0
COOL
WET
376
16.7
MFZ-KA09NA
HEAT
DRY
332
15.4
COOL
WET
303
14.2
MFZ-KAl2NA
HEAT
DRY
335
15.6
COOL
WET
309
14.5
MFZ-KA18NA
HEAT
DRY
434
20.0
COOL
WET
379
17.5
SLZ-KA09NA
HEAT
DRY
350
12.1
COOL
WET
320
1.1
SLZ-KAl2NA
HEAT
DRY
390
13.5
COOL
WET
350
12.1
SLZ-KA15NA
HEAT
DRY
390
13.5
COOL
WET
350
12.1
`Air coverage represents the distance with one fVsec air speed when blowing out
horizontally from the unit operating at the High fan speed. This is only a general
guideline; actual coverage depends on size and layout of the room.
31
Heating Capacity
Outdoor
Temperature
13.0
-4.0
5.0
14.0
23.0
32.0
41.0
50.0
Degrees C F)
MSZ/MUZ-FH09NA
Heating Capacity
7,303
9,047
10,682
10,900
10,900
10,900
10,900
10,900
(Btu/h)
Percentage of
67%
83%
98%
100%
100%
100%
100%
100%
Rated Capacity
Heating Capacity
91928
11,696
13,600
13,600
13,600
13,600
13,600
13,600
(Btu/h)
Percentage of
730/6
86%
100%
100%
100%
100%
100%
100%
Rated Capacity
Heating Capacity
14,580
16,200
18,000
18,000
18,000
18,000
18,000
18,000
(Btu/h)
Percentage of
81%
90%
100%
100%
100%
100%
100%
100%
Rated Capacity
Heating Capacity
14,210
17,255
20,300
20,300
20,300
20,300
20,300
20,300
(Btu/h)
Percentage of
70%
85%
100%
100%
100%
100%
100%
100%
Rated Capacity
32
Outdoor
Temperature
-13.0
-4.0
5.0
14.0
23.0
32.0
41.0
50.0
Degrees( F)
r
•d
Heating Capacity
20,460
21,120
22,000
22,000
22,000
22,000
22,000
22,000
(Btu/h)
Percentage of
93%
96 %
100%
100%
100%
100%
100%
100%
Rated Capacity
[Non -Ducted]
Heating Capacity
22,500
23,750
25,000
25,000
25,000
25,000
25,000
25,000
(Btu/h)
Percentage of
90%
95%
100%
100%
100%
100%
100%
100%
Rated Capacity
r
r
Heating Capacity
25,168
26,884
28,600
28,600
28,600
28,600
28,600
28,600
(Btu/h)
Percentage of
88%
94%
100%
100%
100%
100%
100%
100%
Rated Capacity
Heating Capacity
34,200
39,600
45,000
45,000
45,000
45,000
45,000
45,000
(Btu/h)
Percentage of
76%
88%
100%
100%
100%
100%
100%
100%
Rated Capacity
Heating Capacity
36,480
42,240
48,000
48,000
48,000
48,000
000
48,000
(Btu/h)
Percentage of
76%
88 %
100%
100%
100%
100%0
%
100%
Rated Capacity
;54,000
Heating Capacity
41,040
47,520
54,000
54,000
54,000
54,000
54,000
(Btu/h)
Percentage of
76%
88%
100%
100%
100%
100%
100%
100%
Rated Capacity
33
MXZ-Series Accessories
BV-Series Ball Valves
Al DIAMONDBACK
o V�
USTED N1N
R RIGGERPM �
Model numbers:
BVI4FFS12 BV12FFS12
BV38FFS12 BV58FFS12
P. Engineered for Mini -split
and Multi -split HVAC Units
► Full Port Design
► 700 PSIG Rated = s I Lo/ is1 123 �42 110
�eresr_ .M. s.� zs2 1.e1 111 1.42 1.10
► R-410A Compatible evlz+siz rz s51 2s/ 1 a1 123 1.4z 1.10
3V58FFSI2 5/8• 6.6� 2.6] 1.81 ^.23 1.42 1 10
► Flare Connections
Forged and machined one Ball valves come with an insulation piece
►
piece unibody construction
► Sizes available: 1/4"; 3/8"; 1/2"; 5/8"
► Fully factory assembled.
► Furnace brazed and pressure tested.
► Each ball valve is equipped with
4-1/4" Schrader® valve for
refrigerant service.
► Design working pressure: 700 PSIG.
► Temperature range: -40' F to +325° F
(-40" C to +149* C).
► Forged and machined brass unibody
designed with forged brass seal cap.
► Polytetrafluroethylene (PTFE) seals
and gaskets (no synthetic 0-rings).
► Seal cap design permits valve
operation without removal of
seal cap.
► Uses suitable for with R-11, R-22,
R-123, R-125, R-134A, R-236FA,
R-4202A, R-40213, R-404A, R-407C,
R-410A, R-500, R-502,and R-507.
► One year limited materials
and workmanship warranty
on ball valves.
Platform Stands
��fAMONDBACK"
Lift the Mitsubishi Electric Comfort
Solution outdoor unit to new heights with
our Diamondback Platform Stands.
Is easy to install.
• Available for all sizes of M- and P-Series outdoor units.
• Is color matched to the outdoor units
• One-year warcaty.
Model Number: DSDn-400N
34 L: 15-3/ x IN: 3-1/4" x H: 3-1/4"
M-Series Sizing
It is very important that all contractors follow proper procedure and
size units based on a Manual J calculation. A load calculation takes
into account all the factors that cause the building to lose heat in the
winter and gain heat in the summer. Some of the factors taken into
consideration are exposed walls, insulation, windows, doors, and even
the direction the building faces.
Inverter technology has changed the way heat pumps are used.
Because the INVERTER -driven compressor can vary the capacity of
the system, we can now size units based on the largest load, which in
many cases may be the heat load. When single speed compressors
are sized on heat load and changed over to cooling, the units can be
grossly over -sized. The result is very little dehumidification and comfort
problems.
Using charts like the ones below from the technical service manual,
you can check the equipment capacity at the design temperatures for
heating and cooling. If these values fall within both the heating and
cooling capacity ranges of the system, you can select that system with
confidence.
MSZ/MUZ-FHO9NA
HEATING CAPACITY
Outdoor Tempera-
_13.0
-4.0
5.0
14.0
23.0
32.0
41.0
50.0
ture Degrees ( F)
Heating Capacity
7,303
9,047
10,682
10,900
10,900
10,900
10,900
10,900
(Btu/h)
Percent Heating
67%
83%
98%
100%
100%
100%
100%
100%
Capacity
COOLING CAPACITY
IndcorAir
Outdoor intake air DB temperature (" Fj
86
95
104
115
IWB C
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
TC
SHC
TPC
71
10.3
6.5
0.63
9.7
6.1
0.68
9.0
5.6
0.72
8.3
5.2
0.75
67
9.7
7.4
0.60
9.0
6.8
0.65
8.4
6.4
0.69
7.7
5.8
0.72
63
9.1
8.1
0.58
8.5
7.6
0.62
7.7
6.9
0.66
7.0
6.3
0.69
Notes: IWB: Intake air wet -bulb temperature
TC: Total capacity
SHC: Sensible heat capacity
TPC: Total power consumption (kW) 35
Controllers
MHK1 Wireless
Remote Controller Kit
Exclusive for INVERTER -driven M- and P-Series Systems
A�� nccaoe
f�,
0
Q�
i
MRCH1
■ LIN
Wireless Technology
Wireless Wall -mounted
Remote Controller
o. Backlit, easy -to -read display.
Dual setpoint control with system changeover.
Enabled with RedLINKTm reliability.
oInstalls anywhere with simple wall -mounted design.
o. Compatible with MCCH1 Portable Central Controller and MOS1
Outside Air Sensor.
Requires wireless interface (included in kit).
MIFH1 Wireless Receiver
o. Required for MRCH1 Wireless Remote Controller.
Enabled with RedLINK reliability.
36
Controllers
MHK1 Wireless
Remote Controller Kit
Portable Central Controller
P. Up to 16 RedLINKTm devices.
.. ► Requires MHK1 per indoor unit.
s- ► Monitor and control On/Off, Mode,
and Set Temp.
► Schedule override capability.
P. Does not interfere with other
wireless devices.
MCCH1 ► Displays outside air temperature
and humidity when used with MOS1.
Outside Air Sensor
► Monitors outside air temperature
and humidity.
► Displays on MHK1 Wireless
Wall -mount Remote Controller and
MCCH1 Portable Central Controller.
37
Controllers
Thermostat Interface
Our Thermostat Interface allows HVAC thermostats or input/output
controllers to control Mitsubishi Electric Cooling & Heating commercial
or residential indoor units through our CN105 connector. Any indoor
unit that can be controlled by MHK1 can now be controlled by a third
party HVAC thermostat or input/out controller.
This allows Mitsubishi Electric systems to use the capabilities of third
party thermostats including but not limited to:
Geo-fencing.
Automatic scheduling.
Humidity control.
Set temperature range (dependent on indoor unit)
► Weather forecasting and more.
Our patent -pending algorithm allows the outdoor unit's INVERTER -
driven compressor to vary its capacity for greater energy savings. The
preferred system setup is to use a conventional system control with
two stages of heating and cooling (W1, W2, Y1, and Y2). This will
provide the most comfort and energy savings. The interface can be
setup to accept only one stage of heating and cooling (W1 and Y1).
Mitsubishi Electric Thermostat Interface also allows for fan speed
control. Third party thermostats or input/output controllers can
control the indoor unit's fan speed to three different levels: High,
medium, and low.
38
Controllers
Specifications
► Allows an HVAC Thermostat or 1/0 Controller to control a Mitsubishi
Electric Cooling & Heating [CITY MULTI, M-Series or P-Series]
indoor unit.
► One Thermostat Interface per indoor unit.
► Indoor unit modes available: Cool, Heat, Fan, and Off.
► Provides 3 input terminals to control fan speed control: High,
Medium, and Low.
► Addressing: No addressing required.
► Connection: CN105 - Active IT Terminal.
► Thermostats Tested:
• Nest®
• Honeywell® LyricTM
• INNCOM° by Honeywell° with High and Low fan
speed control.
► Dimensions: (H x W x D) 3.96 in x 3.17 in x 0.93 in.
P. Terminal Block: 20-30 VAC Rated.
► Required: Active CN105 on Mitsubishi Electric indoor unit
control board.
► Required: HVAC Thermostat or 1/0 Controller (field supplied).
► Required: 24VAC circuit for HVAC Thermostat (field supplied).
Advanced Features
► Delayed off adjustable setting.
► Static pressure adjustable setting.
P. CN24 operation during defrost.
► Fan speed during thermal off heating mode.
► Two -stage heat and cool thermostat operation.
► Conventional 2h/2c system operation (preferred).
P. Conventional 1 h/1 c system operation.
P. Auto recovery after power failure.
► Thermostat detects room temperature.
39
Controllers
MHK1 Wireless 1] PI
Remote Controller Kit
s r< 4 4
DescriptionFunction
ON/OFF
On/Off operation for a single indoor unit
Cool / Drying / Auto / Heat / Fan only Available
Operation Mode
operation modes dependent upon connected
system.
Temperature Setting
Set temperature from 40° F - 99° F depending on
operation mode and connected system
System Changeover
2° F 8° F
Deadband Value
Schedule Operation
5-2, 5-1-1
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto. Available fan speed
settings dependant upon connected system.
Airflow angles: 1000 - 800 - 600 - 400 and oscillate.
Air Flow Direction Setting
Available air flow direction settings dependent upon
connected system.
Individual prohibit operations for each remote
Permit/Prohibit Function
controller function (ON/OFF, Set Temperature, and
Mode).
Space Temperature
Displays the measured space temperature.
Error Indication
Displays error code.
Display Outside
Temperature
Requires optional MOS1 Outside Air Sensor
and Humidity
Dimensions - (W x D x H)
Remote Controller: 5-3/16" x 1-1/2" x 3-9/16"
Receiver: 3-1/4" x 1-5/16" x 6-7/16"
Operating Ambient
Remote Controller: 32 - 120° F Receiver: -40 -
Temperature
165° F
Operating Ambient
Remote Controller: 5 percent - 90 percent RH
Humidity
(non -condensing) Receiver: 5 percent - 90 /o RH
(non -condensing)
Power Supply
2 AA batteries (included)
40
Controllers
Handheld
Wireless Controller
Wireless
Standard for M-Series wall -mounted and floor -mounted
systems and optional for P-Series indoor units
Operatic
Sele
(Heat, Co(
Auto, Di
Econo
Cool
Smart SE
Butto
Reset
CI
SE
Slidi
Col
Powerful Mode and
Wide Vane Control buttons are
available on models
MSY(2)-GE24/D30/D36NA
GE model remote
shown, models vary
41
Controllers
Wired Controllers
Simple MA
Controls group operation for up to 16 indoor units
in a single group
► Supports both Fahrenheit and Celsius.
► User defined functions:
• ON/OFF.
• Operation mode: AUTO (R2-Series only),
COOL, HEAT, FAN, DRYING,
or SETBACK.
33 r.
. Set temperature.
• Fan speed setting.
• Air flow direction.
rlj� •w�[
• Set temperature range: 40' F - 95' F
depending on operation mode and indoor
unit connected.
► Set temperature range limit can be reduced for cool and heat
modes.
► LOSSNAY®: Simple MA for interlocked system can set high/low/
Stop on LOSSNAY.
► Room temperature can be sensed either at the indoor unit (default)
or at the remote controller.
► Diagnostics: Displays four -digit error code and error unit address.
► Grouping: Same group use only with other PAC-YT53CRAU Simple
MA Controllers, PAR-31 MAA Wired MA Remote Controllers, and
PAR-FUA32MA Wireless MA Remote Controllers with up to two
remote controllers per group.
► Addressing: No addressing required.
► Wiring: connects using two -wire, stranded, non -polar control wire to
indoor unit connection terminal or control adapter (MAC-3331F for
M-Series) requires crossover wiring for indoor unit grouping.
► Dimensions: 2-3/4" x 9/16" x 4-3/4" (70mm x 14.5mm x 120mm).
42
Controllers
Wired Controllers
Wired MA
28.5r
24.0r.
�__.M now�
Controls group operation for up to
16 indoor units in a single group
► Features selectable multi-
lingual LCD (English, Spanish,
and French).
User functions allow user to set:
► Timer Operation:
• Weekly Timer: On/Off/
Temperature setting up to 8
times per day of the week in
1-minute increments.
• Simple Timer: On and Off
time can be set once within
72-hour period in 1-hour
increments.
• Auto -off Timer: Turns indoor
unit Off based on countdown
time up to 4-hours in
30-minute increments.
► Room Temperature: Displays
room temperature sensed
either at the indoor unit (default)
or at the remote controler.
► Set Temperature Range Limit:
From the Backlit MA Controller,
the allowable set temperature
range can be reduced for cool
and heat modes.
► Special Function Rotation/
Backup (Lead/Lag for P-Series).
P. Static pressure setting (model
dependent)
P. Fan speed setting for use with
supplemental heating function
(model dependent).
► Function Lock Out: Prohibits all
functions or all functions except
On/Off from the backlit MA
controller.
P. Wiring: connects using two -
wire, stranded, non -polar
control wire to indoor unit
connection terminal or control
adapter (MAC-3331F for
M-Series) requires crossover
wiring for indoor unit grouping.
► Dimensions:
4-3/4" x 3/4" x 4-3/4"
(120mm x 19mm x 120 mm)
43
P-Series Indoor Units
Connect to cooling -only PUY and heat pump PUZ
INVERTER -driven compressor outdoor units.
PKA Wall -mounted Series
Cooling -only and Heat Pumps
(12,000 to 34,200 Btulh)
► Provides cooling and heating in a
wide range of capacities.
► Auto flap shutter.
► Auto fan control.
► Easy -clean washable filters.
► Multiple controller options.
PCA Ceiling -suspended Series
Cooling -only and Heat Pumps
(24,000 to 42,000 Btulh)
► i-seeTM Sensor optional.
► Knockout for ventilation air.
P. Auto fan speed control. ®%�e �. •
►ii
Optional, high -efficiency filter. ---' 3
► Multiple controller options.
PLA Ceiling -recessed Series
Cooling -only and Heat Pumps
(12,000 to 42,000 Btulh)
► Built-in condensate
lift mechanism (33" lift).
► Branch duct outlet.
► i-seeTM Sensor optional.
► Knockout for ventilation air.
► Multiple controller options.
44
__a +
__ ?,.
a
1�
�
PVA Multi -position Air Handling Units
Provides cooling and heating to larger zones
(18,000 to 42,000 Btu/h)
► Performance: One inch foam R4.2,
fiberglass -free insulation reduces
condensation and boosts efficiency.
P. Quality: durable, powder
38e
coated cabinet. _V � �"�
P.Serviceability: easily removable 7 � a
fan provides access for coil cleaning.
P.Flexibility: true multi -position, requiring
no additional kits for downflow configuration.
► Installation: quality construction with disassembly
in mind to make fitting through tight access points simple.
► Comfort: DC motor ensures quiet and
efficient operation year round.
► Low Impact: fully RoHS compliant to reduce carbon footprint.
► Air Quality: positively pressurized cabinet and tested air leakage
less than 1 %.
PEA/PEAD Horizontal Ducted Series
Cooling -only and Heat Pumps
(12,000 to 42,000 Btu/h) W
► Automatic fan
speed control.
P. Built-in condensate
lift mechanism (21 11/16" PEA,
27 9/16" PEAD lift).
► Adjustable static pressure.
► Multiple controller options. _
"zee :• � ! L:�l
P-Series Systems
Specifications
(Cooling Only)
Indoor Unit
Model #
Outdoor Unit Model #
Cooling Capacity Range
(Btu/h)
6,000-12,000
8,000-18,000
12,000-24,000
SEER Range
14.0-15.2
14.2-15.3
14.0-17.0
Lineset Size
1/4" x 1/2"
1/4" x 1/2"
3/8" x 5/8"
(Liquid x Gas)
Lineset Length/Height Max
1657100'
1657100'
225A 00'
Separation
Test conditions are based on AHRI 210/240.
► i Seacoast Protection Coating
► P-Series models 12K-36K Btu/h are pre -charged for up
to a 70' line set. PUY/Z-A42NHA5 and H2i models are
pre -charged for up to a 100' line set.
46
PEAD-A30AA5 PEAD-A36AA5 PEAD-A42AA5
PKA-A30KA6 PKA-A36KA6 PLA-A42BA6
PLA-A30BA6 PLA-A36BA6 PCA-A42KA6
PCA-A30KA6 PCA-A36KA6
PUY-A30NHA6(-BS) I PUY-A36NHA6(-BS) I PUY-A42NHA6(-BS)
P-Series Systems
Specifications
(Heat Pump)
Indoor Unit
Modelq
i
r.,
r ,
r
Outdoor Unit
Model q
Cooling Capacity
8,000-18,000
12,000-24,000
12,000-30,000
12,000-35,000
Range (Btu/h)
Heating Capacity
8,000-20,000
12,000-28,000
12,000-34,000
12,000-38,000
Range (Btu/H)
SEER/
14.2-15.3/
14.0-17.0/
14.0-15.5/
14.0-15.0/
HSPF Range
9.5-10.0
8.5-10.9
8.7-9.4
9.3-10.2
Lineset Size
(Liquid x Gas)
1/4" x 1/2"
3/8" x 5/8"
3/8" x 5/8"
3/8" x 5/8"
Lineset Length/
Height Max
1001/100,
165'/100'
1657100'
165'/100'
Separation
Test conditions are based on AHRI 210/240.
BS= Seacoast Protection Coating
P-Series models 12K-36K Btu/h are pre -charged for up to a 70' line
set. PUY/Z-A42NHA6 and 112i models are pre -charged for up to a
100' line set.
48
(2)PEA-Al 8AA6
PEAD-A30AA5
PEAD-A36AA5
PEAD-A42AA5
PEAD-A42AA5
PKA-A30KA6
PKA-A36KA6
PKA A42KA6
PLA-A42BA6
PLA-A30BA6
PLA-A36BA6
PLA-A42BA6
PCA-A42KA6
PCA-A30KA6
PCA-A36KA6
PCA-A42KA6
PVA-A30AA4
PVA-A36AA4
PVA-A42AA4
PUZ-A42NHA6
(-BS)
PUZ-HA30NHA6
PUZ-HA36NHA6
PUZ-HA42NKA
P-Series Systems
Correction Factors
Cooling Capacity Correction Factor (x capacity)
PUY-Al2/18NHA6
PUZ-A18NHA6
1.00 0.985 0.948
0.916
0.886 0.859
PUY-A24-36NHA6
PUZ-A24-36NHA6
1.00
0.988
0.964
0.938
0.915
0.893
PUY-A42NHA6
PUZ-A42NHA6
1.00
0.985
0.948
0.916
0.886
0.859
Hyper -Heating INVERTER (H2i®)
Cooling Capacity Correction Factors (x capacity)
PUZ-HA30NHA6
PUZ-HA36NHA6 1.00 0.985 0.957 0.931 0.908
PUZ-HA42NKA
Heating Capacity Correction Factors (x capacity)
PUZ-HA30NHA6
PUZ-HA36NHA6 1.00 0.997 0.991 0.985 0.979
PUZ-HA42NKA
s0
Heating Capacity Correction Factors (x capacity)
165 ft
Refrigerant
180 ft230
piping length (one
way)
260 ft
ift
Eft
260 ft
165 ft
Refrigerant
180 ft
piping length (one
195 ft
way)
230 ft
N®
r• r
.•
.
51
P-Series Air Coverage Range
Outlet Air Speed and Coverage Range*
Model
PLA-Al2BA6
530
8.5
13
PLA-Al8BA6
640
10.5
15
PLA-A24BA6
640
10.5
15
PLA-A30BA6
740
12.1
18
PLA-A36BA6
1060
17.4
26
PLA-A42BA6
1090
17.7
26
PKA-Al2HA6
425
20.0
35
PKA-Al8HA6
425
20.0
35
PKA-A24KA6
775
19.7
47
PKA-A30KA6
775
19.7
47
PKA-A36KA6
920
22.3
53
PCA-A24KA6
670
10.2
32
PCA-A30KA6
705
10.5
33
PCA-A36KA6
990
11.8
41
PCA-A42 KA6
1,025
12.1
42
*A r coverage represents the distance with 0.8 f /sec air speed when blowing
out horizontally from the unit operating at the High fan speed. This is a general
guideline; actual coverage depends on size and layout of the room.
52
Installation
Required Tools for Installation
• Phillips screwdriver.
• Micron gauge.
• Pipe cutter with reamer.
• 3" (75mm) hole saw.
• Level.
• Charge hose for R410A.
• Flaring tool.
• 1/4" - 5/8" torque wrench.
• Scale.
• Gauge manifold for R410A.
• Nitrogen.
• 5/32" (4mm) hexagonal wrench.
• Utility knife or scissors.
• Adjustable wrenches.
• Vacuum pump.
Condensate Drain Pipe Installation
Yes: No:
�' � �• Tq0
to PVC dmn
T.
1J)IAAI 'r
53
M-Series Wall -mounted System Clearances
za/8"
or more/
4" or in
for left
left ba,
Piping u,
space
Applies to all M-Series models except MXZ-8C48NA.
Check installation instructions for your exact model.
54
P-Series Outdoor System Clearances
To illustrate the minimum space required around the outdoor unit, the
clearances for all P-Series models are shown below. See installation
manual for the minimum clearances by model.
3-15/16"or more if no
obstacle is placed at the rear
or right or left side of the unit
13-25132"
*2 �VV
39-3/8" 5-29/32"
2 sides should be open in
the right, left and rear side.
Minimum installation space for outdoor unit
"1. In a place where short cycling can occur, cooling and heating
capacity will decrease and power consumption will increase by 10
percent. Air outlet guide (PAC-SG58SG-E for PUY/PUZ-Al2/18NHA
or PAC-SG59SG-E for PUY/PUZ-A124/30/42NHA) will help improve
capacity.
'2. If air is discharged onto a wall, the surface may discolor.
55
Installation
Refrigerant Piping
Installing Refrigerant Piping
For 'Twinning" indoor units for better airflow coverage
in a large or L-shaped room (For A24/A36, and HA36
outdoor units only).
Refrigerant piping limitations of length and height
difference are shown in the figure below.
Max. length, PUY/PUZ-A24/36NHA systems:
a1+a2+bs165ft
Max. length, PUZ-HA36NHA hyper -heating systems:
a1 +a2+b<245ft
Key:
A = Indoor unit
B = Outdoor unit
C = Multi distribution pipe (option)
d = Height difference (Indoor unit -Outdoor unit) Max. 100 ft.
e = Height difference (Indoor unit -Indoor unit) Max. 3 ft.
56
How to Check for Refrigerant Restriction:
1. Verify the refrigerant charge.
• Remove the charge and weigh it back in.
• Make sure the system has the refrigerant amount specified for the
line length (see Service Manual).
2. Measure for temperature differences across evaporator.
• Set unit operation to cooling and change temperature set point
to lowest degree available, or switch system to emergency COOL
mode.
• Change fan operation to high speed.
• Run system for five minutes, and then measure both the entering
and leaving air temperatures with a thermometer.
• The temperature differential should be around
20° F to 23° F (see Service Manual).
• Remove the charge and weigh it back in.
• Make sure the system has the refrigerant amount specified for
the line length (see Service Manual). Assuming you have verified
the charge, a difference of less than 20' F means the system is
restricted.
A difference of 23° F or more usually means low airflow, often because
dirt has built up on the fan blades. Clean the fan and coil and check
temperatures again.
Note: When testing the system, remember to change the fan operation
to high speed and verify that the unit is charged with the proper
amount of refrigerant.
57
Installation
Wiring: M-Series
and P-Series
P. Indoor unit power is supplied from the outdoor unit.
► On M-Series models, use AWG-14-3 600 VAC -rated copper
wiring between outdoor unit and indoor unit for high voltage
and controls circuits.
► On P-Series models, use AWG-16-3 600 VAC -rated copper
wiring between outdoor unit and indoor unit for high voltage
and controls circuits.
► If larger gauge wiring is required by code - use that on
S1 and S2 terminals while using proper wire size on S3
communication terminal (16 gauge on P-Series and 14 gauge
on M-Series).
► Two types of connection patterns, for 1:1 system and for
P-Series "twin" operation ("twinning") are shown in the
diagrams at right.
Key:
A = Outdoor unit power supply
B = Wiring circuit breaker or isolating switch
C = Outdoor unit
D = Indoor unit/Outdoor unit connecting wiring
E = Remote control
F = Indoor unit
Note: All wiring shall comply with NEC and local
electrical codes. See unit installation manual for details.
58
INDOOR UNIT
Notes:
Terminal Block
Ground
' A disconnect
Terminal
switch may be
required at
F sz ss
indoor unit.
'* Use a ring
tongue terminal
'TAZ-MS303
if AWG12 wire
3 Pole Disconnect
00
is used.
208/230V AC
DC Control
1 Phase, 60 Hz
Circuit
12-24V DC
Power Supply 1J a si sz ss
208/230V AC Ground
rz
1 Phase, 60 Hz
Terminal
OUTDOOR UNIT
"Twinning" Operation
Power Supply
208/230V AC C 208/230V AC F F
L1 E 1 01
A B 1-2 2 02
GR
S2 S2 S2�
S3 S3 S3
1 'TAZ-MS303 _ 1
D
12-24V DC
59
Installation
Test Run
1. Turn power on to outdoor unit.
2. Press the emergency operation button
once. The test will run for 30 minutes. If E115--i
the LED light blinks every 0.5 seconds,
verify the indoor/outdoor connecting wire Emergency operation switch
is installed properly. After the test run, the (E.O. SW)
emergency COOL mode (75' F) will operate.
3. To stop operation, press the emergency operation button
several times until all LED lights turn off. See operation
manual for details.
Checking the Remote (Infrared) Signal Reception
1. Press the ON/OFF button on the remote controller and listen for a
beep from the indoor unit.
2. Press the ON/OFF button again to turn the air conditioner off.
3. After the compressor stops in the outdoor unit, the restart
prevention device will activate. This causes the compressor to stop
operation for three minutes, which protects the air conditioner.
Caution:
After finishing the test run or checking the remote (infrared) signal
reception, use emergency operation button or remote controller to turn
unit off before turning power supply off. If this sequence is not followed
properly, the unit will start operating automatically when the power
supply resumes.
Need Help When You Are On The Jobsite?
Check out www.mylinkdrive.com
Here you can find: service bulletins, FAQs, Guide Specs,
Install Manuals, MSDS sheets, Operation Manuals, Parts
Lists, Service Manuals, Submittals, Accessories and the M&P
troubleshooter.
60
Auto Restart Function:
Mitsubishi Electric systems are equipped with an auto restart
function. If the power shuts off while the system is operating
(blackouts, etc.), the system will automatically resume
operation at the previous setting after the power resumes.
If the end user prefers not to use this function, a service
representative can deactivate it. See Operation Manual
for details.
Necessary End User Information:
After installation, show the end user how to operate
the system remote controller and remote controller
holder, remove the air filter, cleaning methods, operating
precautions, etc. Recommend that the end user read the
Operation Manual.
Continuous Fan Operation:
Explain to the end user that the indoor unit fan is designed
to continuously run air across the filters. A sensor also
constantly measures room temperature to maintain set point.
These functions help improve air quality and reduce wear and
tear on the fan motor.
61
Ducting Considerations
Ducting Considerations for the PEA/PEAD/SEZ
Horizontal Ducted Indoor Unit
Considering the performance and design of these indoor units,
selection and proper duct sizing and installation are necessary for
satisfactory operation.
The maximum available static pressure from the PEA and
SEZ indoor units is 0.2 in. W.G. and for the PEAD indoor
units 0.6 in. W.G.
Most of the static pressure duct loss comes from allowing the duct
work to sag. Allowing even a 30 percent sag in the ductwork can
increase the static pressure loss up to eight times. Flexible ductwork
runs should be kept to less than 15 ft.
Airflow (CFM) 50 100 150 200 250
Grille Size (In. x In.) 6x6 6x6 8x6 10x6, 8x8 12410x8
Inches of Static Pressure Loss per 100 ft. of hard duct
4" 0
6" 0
8" 0
10"0
50 CFM
0.15
0.02
-
100 CFM
0.6
0.08
0.02
150 CFM
-
0.2
0.04
-
200 CFM
0.3
0.08
0.02
250 CFM
0.45
0.11
0.04
500 CFM
-
0.4
0.15
62
LIMITED WARRANTY INFORMATION
AlkMITSUBISHI
ELECTRIC
Effective APRIL, 2015
M-Series Warranty:
P. 12-year parts and 12-year compressor warranty is available to the
original owner provided the system is:
• Installed by a Diamond Contractor in a residential single-family
owner -occupied home.
• Registered by the installing contractor through the Extranet within
90 days of installation.
► 10-year parts and 10-year compressor warranty is available to the
original owner provided the system is:
• Installed by a licensed contractor in a residential single-family
owner -occupied home.
• Registered through the MitsubishiComfort.com site, within 90
days of installation.
P. 5-year parts and 7-year compressor warranty will come standard to
the original owner.
P-Series Warranty:
► 12-year parts and 12-year compressor warranty is available to the
original owner provided the system is:
• Installed by a Diamond Contractor in a residential single-family
owner -occupied home.
• Registered through the Extranet within 90 days of installation.
P. 10-year parts and 10-year compressor warranty is available to the
original owner provided the system is:
• Installed by a licensed contractor in a residential single-family or
commercial application.
• Registered through the MitsubishiComfort.com site within 90 days
of installation.
► 5-year parts and 7-year compressor warranty will come standard to the
original owner.
The full text of this Limited Warranty is available on the Mitsubishi Electric website, The
Limited Warranty gives the owner specific legal rights and the owner may also have other
rights that vary from state to state. Some states do not allow limitations on warranties or
exclusions or limitation of damages, so the specified limitations or exclusions may not
apply. This Limited Warranty Is valid only in the continental United States, Alaska and
Hawaii and is not transferable.
For more information, contact. Customer Care: 800-433-4822
Web: http://www.mitsubishipro.com 63
Synchrony Financing
Getting Started is as Easy as 1,2,3!
Go to toolbox and take selling strategies:
► toolbox. mysynchrony.com/diamondEnroll.
► Download the rate menu for available plans.
P. Follow the Commitments guide focusing on getting team trained
Download this Synchrony Contacts flier for training and more
information.
Think Outside the Toolbox!
Announcing the Selling In The Home Webinar Training Series
What if you worked as hard on your business as you work in your
business? You use your knowledge and skill to choose the right tool
for the job. So why not put that same sharp focus to work growing
your business? Synchrony Financial is excited to invite you to Think
Outside the Toolbox —a website dedicated to helping you grow your
business by closing more projects.
As part of our commitment to bringing you useful tools and fresh
ideas, we've leveraged insights from our largest partners in the Home
Improvement, HVAC, Spa and Landscape industries, and combined
them with Synchrony Financial's expertise. In addition, Synchrony
Financial teamed up with Dave Yoho Associates to develop the
materials in theSelling In The Homewebinar series. We invite you to
take advantage of all this knowledge and experience today.
64
Take the first step toward growing your business by visiting our Think
Outside the Toolbox website at: toolbox.mysynchrony.com/diamond
Once there, you will complete a quick site registration and be offered
two series of training webinars. Each webinar training series consists of
two 15-20 minute webinars, and two short quizzes.
In the Selling In The Home webinar series you will learn:
► The critical role of consumer financing throughout the sales process.
► Common myths about financing.
► How to set a good first impression with the customer.
► Tips on how to present your company and products.
► How to close the sale leveraging special promotional
financing options.
Receive a $25 Visa® Gift Card' for completing each webinar training
series and corresponding quizzes.
65
MITSUBISHI 1
/_ ELECTRIC MAKE COMFORT nQp�O►1C11
COOLING & HEATING v
Mitsubishi Electric, H21, CITY MULTI, Lossnay and the three diamond logo
are registered trademarks of Mitsubishi Electric Corporation, Lyric, Inncom
and RedLlnk are trademarks of Honeywell Corporation. Nest is a trademark
of Google, Inc. Use of the AHRI CertifiedTM Indicates a manufacturer's
participation in the certification program. For verification of certification for
individual products, go to www.ahridirectory.org.
See complete warranty for terms, conditions, and limitations.
A copy is available from:
Mitsubishi Electric, 1340 Satellite Blvd, Suwanee, GA 30024
Specifications subject to change without notice.
For more information visit www.mehvac.com
T
J,� onslerfrom f�,g c�1�.
FSC rasa nia &oGroas T
FSC® C009723 Intertek
MQR 10.2015 REVISED SKU: MQR0710_V1
Customer Care: 800-433-4822 1 Printed In The U.S.A
02015 Mitsubishi ElectricUS, Inc.