Loading...
BLD2024-1074_Manufacturer_Specifications_and_Installation_Instructions_8.15.2024_5.26.26_PM_4444344MITSUBISHI ELECTRIC COOLING & HEATING M-SERIES & P-SERIES Pocket Reference Guide mitsubishipro.com MAKE COMFORT Per" ggal ® 2015 Mitsubishi Ele tnc US, Inc. I Form No. MORO 10.20151 REVISED MITSUBISHI /_ ELECTRIC COOLING & HEATING ✓ Pre -visit Checklist Verify appointment ✓ Call 30 minutes before you arrive ✓ Verify equipment in stock at distributor ✓ Credit application/financing options ✓ Local rebate information Bring this booklet along so you have product information and the contact phone numbers below handy Customer Care: 800-433-4822 www.mitsubishipro.com Advanced Technology. Superior Comfort. Split -zoning is the most popular type of air-conditioning technology in the world. Mitsubishi Electric takes split -zoning to a new level —our cooling and heating systems deliver year-round personal comfort even in the harshest of climates. Mitsubishi Electric single- and multi -split systems also feature: Exceptional cooling and heating performance. . Automatic cool/heat changeover. Maximum energy efficiency with higher SEER and HSPF ratings. Easy installation. Environmentally friendly R410A refrigerant. Convenient temperature, fan, and airflow control. . Advanced filtration to help provide high air quality. . Whisper -quiet operation. M-Series components are up to 83% recyclable M-Series was green before green was cool. ENERGY STAR° Mitsubishi Electric systems are now more environmentally friendly than ever! Use them to earn many available state, municipal, and utility rebates. M-Series Qualifying Models* MUY-GE09NA & MSY-GE09NA-9 MUY-GE09NA2 & MSY-GE09NA-9 MUY-GE12NA & MSY-GEI2NA-9 MUY-GE12NA2 & MSY-GE12NA -9 MUY-GEI5NA-1 & MSY-GEI5NA-9 MUY-GE15NA2 & MSY-GEI5NA-9 MUY-GE24NA & MSY-GE24NA MUZ-FE09NA-1 & MSZ-FE09NA-8 MUZ-FE12NA1 & MSZ-FEI2NA-8 MUZ-FE18NA & MSZ-FE18NA MUZ-FH09NA & MSZ-FH09NA MUZ-FH12NA & MSZ-FH12NA MUZ-FH15NA & MSZ-FH15NA MUZ-FH18NA & MSZ-FH18NA MUZ-GE09NA2 & MSZ-GE09NA-9 MUZ-GE12NA2 & MSZ-GEI2NA-9 MUZ-GE15NA2 & MSZ-GEI5NA-9 MUZ-GEI5NA-1 & MSZ-GEI5NA-9 MUZ-GE09NA & MSZ-GE09NA-9 MUZ-GE12NA & MSZ-GEI2NA-9 MUZ-GE24NA & MSZ-GE24NA SUZ-KA09NA & SEZ-KD09NA4 SUZ-KAl2NA & SEZ-KD12NA4 SUZ-KA15NA & SEZ-KD15NA4 SUZ-KA18NA & SEZ-KD18NA4 SUZ-KA09NA & SLZ-KA09NA4 SUZ-KAl2NA & SLZ-KAl2NA4 MXZ-2B20NA-1 w/ Non -Ducted Indoor Units 'ENERGY STAR certified model as of print time M-Series Qualifying Models* MXZ-21320i w/ Specific (reference AHRI Directory) MXZ-21 w/ Non -Ducted Indoor Units MXZ-21 w/ Mixed Ducted and Non -Ducted Indoor Units MXZ-3C24NA w/ Non -Ducted Indoor Units MXZ-31 w/ Specific (reference AHRI Directory) MXZ-31 w/ Non -Ducted Indoor Units MXZ-31 w/ Non -Ducted Indoor Units MXZ-31 w/ Mixed Non -Ducted and Ducted Indoor Units MXZ-3C30NAHZ w/ Non -Ducted Indoor Units MXZ-4C36NAHZ w/ Non -Ducted Indoor Units MXZ-4C36NAHZ w/ Mixed Non -Ducted and Ducted Indoor Units MXZ-5C42NAHZ w/ Non -Ducted Indoor Units MXZ-5C42NAHZ w/ Mixed Non -Ducted and Ducted Indoor Units MXZ-8C48NA w/ Non -Ducted Indoor Units MXZ-8C48NAHZ w/ Non -Ducted Indoor Units P-Series Qualifying Models* PUZ-HA30NHA4 & PCA-A30KA6 PUZ-HA30NHA4 & PEAD-A30AA5 PUZ-HA30NHA4 & PKA-A30KA6 PUZ-HA30NHA4 & PLA-A30BA6 PUZ-HA30NHA4 & PVA-A30AA4 PUZ-HA36NHA4 & PCA-A36KA6 PUZ-HA361 & (x2) PEA-A18AA6 PUZ-HA361 & PEAD-A36AA5 PUZ-HA36NHA4 & PKA-A36KA6 PUZ-HA361 & PLA-A36BA6 PUZ-HA361 & PVA-A36AA44 For tax credit details and forms visit www.mitsubishicomfort.com/taxcredit For details on state and utility rebates visit www.dsireusa.org `ENERGY STAR certified model as of print time Features & Benefits How to Read a Model Number MXZ- 2C 20NA-1 M —Mini-split MODEL VERSION S = Mini -split WIRING METHOD TYPE A = A Control S = Wall -mounted indoor unit E = Horizontal -ducted indoor unit COMPRESSOR U = Single -system outdoor unit VOLTAGE X = Mufti -system Outdoor unit F = Floor -mounted unit W = 115V Compressor L = Ceiling -recessed indoor unit N = 230V Compressor V = Multi -position AHU CAPACITY (nominal) COOLING ONLY /HEAT PUMP In Btu/h (x 1,000) Y = Cooling only (INVERTER) Z = Heat pump INVERTER) SYSTEM GENERATION NUMBER OF ZONES 2 = Max. number of zones M-Series (9,000 - 48,000 Btl 1. Designed for residential applications. 2. User-friendly zoned cooling and heating solutions for single- or multi -room applications or the whole home. 3. Hyper -Heating INVERTERTM (H2i®) outdoor units can provide high heating performance at lower ambient temperatures. 4. Many ENERGY STAR® certified models. 4 How to Read a Model Number PKA-A24KA 4-13S FAMILY T P = Professional BS =Seacoast protection pkg. for outdoor unit TYPE K = Wall -mounted indoor unit MODEL VERSION C = Ceiling -suspended indoor unit L = Ceiling -recessed indoor unit E = Horizontal -ducted indoor unit SYSTEM CONTROLS U = Single system outdoor unit GENERATION V = MulliPosition AHU COOLING ONLY / HEAT PUMP Y = Cooling only (INVERTER -driven) CAPACITY (nominal) Z = Heat pump (INVERTER -driven) In Btu/h (x 1,000) A = Both heating and cooling GENERATION A = Generation A HA = Hyper -heating INVERTER unit 1. For light commercial, industrial, or institutional installations- ideal for applications requiring year-round, low ambient cooling such as computer, elevator and equipment rooms. 2. Hyper -Heating INVERTERTM (1-12M) outdoor units can provide superior heating performance at lower ambient temperatures. 3. Long lineset lengths. 4. Outside air intake on PLA, PCA PEND and PVA models. M-Series Models Our standard line is now greener than ever! GE Models ► Eight ENERGY STAR® models. aOOO P."Smart Set' programming button jwith SETBACK down to 501 F in - 22,500 Btulh) heating (9,000 - 18,000 only). ► Washable 10- ear catechin filter See pares and 1 Y for more information. mation.. and anti -allergy enzyme filter. ► Cooling -only and heat pump models. P. Five fan speeds plus AUTO (Select Models). ► As quiet as 19 dB(A). D Models (30,700 - 34,600 Btu/h) Wide vane mode for precise directional airflow (also available on MSY/Z-GE24NA). Powerful mode for quick 15 minute heating/cooling boost (also available on MSY/Z-GE24NA). Cooling -only and heat pump models. - 150"- With the WIDE VANE or SWING mode, available on the MSYQ-GE24/ D30/36NA there is an option for seven horizontal airflow directions that provide 150' of airflow for greater conditioned air circulation. High -efficiency, Hyper -heating systems FE & FH ModelsArm ► 30.5 - 22.0 SEER, 13.5 - 12.0 HSPF, INVERTER -driven compressor. ► Quiet operation as low as 20 dB(A). (9,000 - 18,000 Btulh) ► Hyper -heating performance down See page is for more information, to minus 13' F outdoor ambient. ► 100% heating capacity at 5° F outdoor ambient. P. Quiet operation as low as 20 dB(A). ► Triple -action filtration. • Nano -platinum filter. • Electrostatic anti -allergen enzyme filter. • Deodorizing filter. ► Energy saving mode. P. Double -vane air delivery for enhanced circulation. • Option to set each vane separately. • Indirect or direct setting option. • Natural flow setting that creates air movement like a natural breeze. P. i-see SensorTm 3D. • Infrared human sensing technologies to measure location of human heat signatures. • Senses floor temperature in order to deliver conditioned air to those areas that need it using double -vane airflow and motorized vertical vanes. ► NEW multi -function hand-held wireless controller or wall -mounted wireless controller available with smart phone control capabilities. MFZ Models �! P. Ideal for low -wall mounted applications. ► Bi-directional airflow (top and bottom discharge). ► "Smart Set' programming button with SETBACK down to 500 F in heating. ( _ P18,OOO Btulh) ► Washable, 10-year catechin filter and See page 19 for anti -allergy enzyme filter. more information. ► For use with MXZ multi -zone outdoor units only. 7 M-Series Models i SEZ Models . Small compact design (7-7/8" height). - to ► Adjustable static pressure. ► Built-in condensate lift mechanism (22-1/2" lift). ► Rear return or bottom return (with optional accessory). ► Low operating sound pressure levels; as low as 23 dB(A). ► All four ENERGY STAR® certified models. See pages 20-21 for more information. SLZ Models ► Fits in 2x2 suspended ceiling grid. ► 4-way airflow. ► Built-in condensate lift mechanism (19-11/16" lift). ► Catechin deodorizing filter. P. Two ENERGY STAR® rated models. ► Outside air intake. MVZ Models ► Performance: One inch foam R4.2, fiberglass -free insulation reduces condensation and boosts efficiency. ► Quality: durable, powder coated cabinet. ► Serviceability: easily removable fan provides access for coil cleaning. (12,000 - 40,000 Btu/h) ► Flexibility: true multi -position, requiring no Seepages 18-19for additional kits for downflow configuration. more information. ► Installation: quality construction with disassemblyin mind to make fitting through tight access points simple. ► Comfort: DC motor ensures quiet and efficient operation year round. ► Low Impact: Fully RoHS compliant to reduce carbon footprint. ► Air Quality: Positively pressurized cabinet and tested air leakage less than 1 %. ► For use with MXZ Multi -zone outdoor units only. 8 MXZ Multi -zone Heat Pumps 2:1, 3:1, 4:1, 5:1, and 8:1 Zoned Solutions (20,000-48,000 Btulh) ► Many combinations have received the ENERGY STAR® certification. ► Precise, individual room comfort control. ► Multiple indoor air handler options (non -ducted and ducted). ► Minimum of two indoor units must be installed. MSZ-FH09 -18NA MSZ-GE06-24NA 10 PLA-Al2-3613A LI (for use with MXZ only) • 1. SEZ-KDO PEAD-A24-36AA5 STANDARD: H21: MXZ -2B20NA-1 MXZ-2C20NAHZ MXZ-3C24NA MXZ-3C24NAHZ MXZ-3C30NA MXZ-303ONAHZ MXZ-4C36NA MXZ-4C36NAHZ MXZ-5C42NA MXZ-5C42NAHZ MXZ-8C48NA MXZ-8C48NAHZ mom MVZ-Al2-36AA4 (for use with MXZ only) Seepages 18-19 for more information. M-Series Models DIAMOND OCOM FORT SYSTEW r. N Outdoor Unit HORIZONTAL -DUCTED INDOOR UNITS FLOOR -MOUNTED INDOOR UNITS 'Illustration purposes only. Refer to compatibility chart for combination allowances. 10 Multi -zone Systems* INDOOR UNITS MULTI -POSITION DUCTED AIR HANDLER INDOOR UNITS M-Series Cooling -only Systems M SY Model Specifications (air conditioners) Indoor Model # Outdoor Model # Rated Cooling Capacity (Btu/h) r 11 Mi ®■ 9,000 12,000 Cooling Capacity Range (Btu/h) 3,800-12,200 3,800-13,600 SEER 23.2 22.7 Lineset Size (Liquid x Gas) 1/4" x 3/8" 1/4" x 3/8" Lineset Length/Height Max. Separation 65740' 65740' Breaker Size 15AMP 15AMP Test conditions are based on AHRI 210/240. 12 MUY-GE15NA-2 MSY-GE15NA-9 14,000 17,200 22,500 30,700 34,600 3,100-18,200 3,700-18,700 8,200-31,400 9,800-30,700 9,800-34,600 21.6 19.2 19 16 15.1 1/4" x 1/2" 1/4" x 1/2" 3/8" x 5/8" 3/8" x 5/8" 3/8" x 5/8" 65740' 100750' 100750' 1001/50, 100'/50' 15AMP 15AMP 20AMP 25AMP 25AMP M-Series units are pre -charged for up to a 25' line set. 13 M-Series Heat Pump Systems MSZ/MUZ H2i® Model Specifications (heat pumps) A 11, A I Indoor Model # Outdoor Model # Rated Cooling Capacity (Btu/h) r MUZ-FHO9NA 9,000 12,000 . Cooling Capacity Range(Btu/h) 1,700-12,000 2,500-13,600 Heating Capacity Range at 47T (Btu/h) 1,600 - 18,000 3,700 - 21,000 Max. Heating Capacity at 17T (Btu/h) 12,200 13,600 Max. Heating Capacity at 5°F (Btu/h) 10,900 13,600 SEER/HSPF 30.5/13.5 26.1/12.5 Lineset Size (Liquid x Gas) 1 /4" x 3/8" Lineset Length/Height Max. Separation 65740' 65740' Breaker Size 15 AMP 15 AMP Test conditions are based on AHRI 210/240. 14 0" 1 MSZ-FH09NA A111 I111 15,000 17,200 6,450 - 19,000 6,450 - 21,000 5,150 - 24,000 5,150 - 30,000 18,000 20,300 18,000 20,300 22.0/12.0 21.0/12.0 1 /4" x 1 /2" 1001/50, 1001/50, 20AMP 20AMP 15 M-Series Heat Pump Systems MSZ/MUZ Model Specifications (heat pumps) Indoor Model # r ®®®. 9,000 12,000 14,000 Outdoor Model # Rated Cooling Capacity (Btu/h) Cooling Capacity Range(Btu/h) 3,800- 12,200 3,800- 13,600 3,100- 18,200 Heating Capacity Range at 47° F (Btu/h) 4,500- 14,100 5,500- 18,100 4,800- 20,900 Max. Heating Capacity at 17' F (Btu/h) 8,700 11,200 15,900 Max. Heating Capacity at 5° F (Btu/h) 7,061 9,194 13,022 SEER/HSPF 23.2/11 22.7/11.4 21.6/11.2 Lineset Size (Liquid x Gas) 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" Lineset Length/ Height Max. Separation 65740' 65740' 65740' Breaker Size 15AMP 15AMP 15AMP Test conditions are based on AHRI 210/240. 16 MSZ-GE09NA-9 MUZ-GE09NA2 .®® MSZ-GE1 8NA-9 17,200 = 22,500 MSZ-D30NA-8 MUZ-D30NA-1 30,700 MSZ-D36NA-8 33,200 3,700- 18,700 8,200- 31,400 9,800- 30,700 9,800- 33,200 3,500- 25,200 7,500- 36,900 8,700- 34,000 8,700- 36,000 17,200 24,600 20,800 22,800 13,562 21,160 16,305 19,090 19.2/10 19/10 14.5/8.2 14.5/8.2 1/4" x 1/2" 3/8" x 5/8" 3/8" x 5/8" 3/8" x 5/8" 100750' 1001/50, 1001/50, 1001/50, 15AMP 20AMP 25AMP 25AMP MSZ-GE24NA and MSZ-FH18NA precharged to 33' line set 17 M-Series Heat Pump Systems MVZ and MFZ for MXZ-C Model Specifications (heat pumps) Indoor Model # ®®®, Outdoor Unit Rated Cooling Capacity (Btu/h) 9,000 12,000 18,000 Rated Heating Capacity at 47' F 10,900 14,400 21,600 (Btu/h) Airflow at Cooling/ Heating(SH-H-M-L) 169-205-251-314 163- 177-215-261-321 251-279-325-394 (H-M-L) (CFM) 197-241-303 170-207-252-309 241-269-313-379 ESP (In. W.G.) Sound at Cooling/ Heating Heatin)(dB�) 40-35-30-25 41-36-31-26 46-42-38-35 40-35-30-25 41-36-31-26 47-42-38-35 Lineset Size (Liquid x Gas) 3/8" x 1/4" 3/8" x 1/4" 1/2" x 1/4" Breaker Size 25AMP 25AMP 25AMP Test conditions are based on AHRI 210/240. 18 MVZ-Al2AA4 12,000 18,000 24,000 30,000 36,000 13,500 20,000 27,000 34,000 40,000 400-340-280 400-340-280 585-497-410 735-625-515 875-744-613 585-497-410 735-625-515 875-744-613 1095-931-767 1095-931-767 0.30-0.50-0.80 35-31-27 35-31-27 36-32-36 36-32-36 38-34-30 38-34-30 40-36-21 40-36-21 43-39-35 43-39-35 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" 1/4" x 1/2" 3/8" x 5/8" 15AMP 15AMP 15AMP 15AMP 20AMP 19 SEZ/SLZ System Specifications (heat pumps) SEZ-KD15NA4 SUZ-KA15NA Indoor Model # r r r Outdoor Model # • r • 8,100 ®®- 11,500 14,100 Rated Cooling Capacity (Btu/h) Cooling Capacity Range(Btu/h) 3,8010-10,900 3,800-13,300 3,800-17,000 Heating Capacity Range at 47' F (Btu/h) q,g00-14,100 4,800-16,400 4,800-21,100 Heating Capacity at 170 F (Btu/h) 6,700 9,000 11,900 SEER/HSPF 15/10 16/10 15.5/10 Lineset Size (Liquid x Gas) 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" Lineset Length/Height Max. Separation 65740' 65740' 65740' Breaker Size (MOCP) 15AMP 15AMP 15AMP Test conditions are based on AHRI 210/240. 20 Pee SLZ-KA15NA W,,, Ordered separately V v v i=� LINK% Wireless Technology MHK1 17,200 8,400 11,100 15,000 3,800-19,000 3,100-10,900 3,400-13,300 3,800-17,700 4,800-24,900 3,100-14,100 3,100-17,100 3,100-22,200 13,100 6,200 8,300 12,000 17.5/10 15/9.6 15.4/9.6 16/9.6 1/4" x 1/2" 1/4" x 3/8" 1/4" x 3/8" 1/4" x 1/2" 1001/50, 65740' 65740' 65740' 15AMP 15AMP 15AMP 15AMP 21 MXZ Series MXZ-C Model Specifications (multi -zone heat pumps) Outdoor Model # Rated Cooling Capacity(Btu/h) r 18,000 22,000 Cooling Capacity Range(Btu/h) 7,800-20,000 12,600-25,500 Heating Capacity Range at 47° F (Btu/h) 8,500-25,500 11,400-30,600 Heating Capacity at 17' F (Btu/h) 12,500 14,000 Individual/Combined Max. Lineset Length 827164' 827230' Max. Vertical Separation 49'*/33' 49'*/49' Breaker Size 20AMP 20AMP SEER/HSPF non -ducted 18.00/8.90 20.00/9.80 SEER/HSPF mixed 16.75/8.70 18.00/9.50 SEER/HSPF ducted 15.50/8.50 16.00/9.20 Test conditions are based on AHRI 210/240. See page 3 for ENERGY STAR® certified combinations. Refer to submittal document for combination performance. ** 131' applies when outdoor unit is installed below indoor unit. 22 Each MXrequires least branch branch box at onere with a maximum of two. Two sizes are available: 3-branch (PACBC) and 5-branch BRANCH BOX (Phown FOR INDOOR UNIT shown above). above). CONNECTIONS MXZ-8C48NA 28,400 35,400 40,800 48,000 12,600-28,400 12,600-36,400 6,000-43,000 6,000-48000 11,400-36,000 11,400-43,000 7,200-53,600 7,200-54,000 16,000 22,200 24,400 36,600 82'/230' 827230' 827230' 2627492' 49'*/49' 49'*/49' 49'*/49' 131'**/164' 20AMP 25AMP 40AMP 50AMP 19.00/10.60 19.20/11.00 19.70/10.30 18.90/11.40 17.60/10.10 17.45/10.40 17.45/9.70 16.80/10.75 16.20/9.60 16.00/9.80 15.20/9.10 14.70/10.10 SEE PAGE 26 FOR INDOOR UNIT CONNECTION CAPABILITIES. See section 5 of installation manual for full details on MXZ-8C48NA refrigeration piping lengths. 23 MXZ Series MXZ-C H2i® Model Specifications (multi -zone heat pumps) I Ilr / Ilr Outdoor Model # Rated Cooling Capacity(Btu/h) r 18,000 22,000 Cooling Capacity Range(Btu/h) 6,000-20,000 6,000-23,600 Heating Capacity Range at 47o F (Btu/h) 7,400-25,500 7,200-30,600 Max. Heating Capacity at 17o F (Btu/h) 22,000 25,000 Max. Heating Capacity at 5° F (Btu/h) 22,000 25,000 Individual/Combined Max. Lineset Length 82'/164' 82'/230' Max. Vertical Separation 49' 49' Breaker Size 40 AMP 40 AMP SEER/HSPF non -ducted 17.00/9.80 19.00/10.00 SEER/HSPF mixed 16.00/9.65 17.25/9.50 SEER/HSPF ducted 15.00/9.50 15.50/9.00 Test conditions are based on AHRI 210/240. See page 3 for ENERGY STAR® certified combinations. Refer to submittal document for combination performance. ** 131' applies when outdoor unit is installed below indoor unit. 24 Each MX7—H2i® requires at least one branch box with a maximum of two. Two sizes are available: 3-branch (PAC-AKA30BC) and BRANCH BOX 5-branch FOR INDOOR UNIT (PAC-AKA50BC, CONNECTIONS shown above). MV-8C48NA I Ilr / Ilr / 117 Ally 28,400 36,000 42,000 48,000 6,000- 28,400 6,000- 36,000 6,000-4 2,000 6,000-4 8,000 7,200-36,000 7,200-45,000 7,200-48,000 7,200-54,000 28,600 45,000 48,000 54,000 28,600 45,000 48,000 54,000 827230' 2627492' 2627492' 2627492' 49'*/49' 131'**/164' 131'**/164' 131'**/164' 40AMP 50AMP 50AMP 50AMP 18.00/11.00 19.10/11.30 19.00/11.00 18.90/11.00 17.00/10.40 17.45/10.70 17.00/10.55 16.80/10.50 16.00/9.80 15.80/10.70 15.00/10.10 14.70/10.00 SEE PAGE 28 FOR INDOOR UNIT CONNECTION CAPABILITIES. See section 5 of installation manual for full details on refrigeration piping lengths. 25 MXZ-Series Port Adapters PORT ADAPTER GUIDE Available Indoor Units Line Set Size MSZ Wall -mounted MSZ-GEO6NA-9 3/8" gas x 1/4" liquid MSZ-GE09NA-9 3/8" gas x 1/4" liquid MSZ-GEI2NA-9 3/8" gas x 1/4" liquid MSZ-GEI5NA-9 1/2" gas x 1/4" liquid MSZ-GEI8NA-9 1/2" gas x 1/4" liquid MSZ-GE24NA 5/8" gas x 3/8" liquid MSZ-FE09NA-8 3/8" gas x 1/4" liquid MSZ-FEI2NA-8 3/8" gas x 1/4" liquid MSZ-FE18NA 5/8" gas x 3/8" liquid MSZ-FH09NA 3/8" gas x 1/4" liquid MSZ-FH12NA 3/8" gas x 1/4" liquid MSZ-FH15NA 1/2" gas x 1/4" liquid MSZ-FH18NA 1/2" gas x 1/4" liquid MFZ Floor -standing MFZ-KA09NA 3/8" gas x 1/4" liquid MFZ-KAl2NA 3/8" gas x 1/4" liquid MFZ-KA18NA 1/2" gas x 1/4" liquid MVZ Multi -position MVZ-Al2AA4 1/2" gas x 1/4" liquid MVZ-Al8AA4 1/2" gas x 1/4" liquid MVZ-A24AA4 5/8" gas x 3/8" liquid MVZ-A30AA4 5/8" gas x 3/8" liquid MVZ-A36AA4 5/8" gas x 3/8" liquid 26 Available Indoor Units Line Set Size PLA Ceiling -recessed PLA-Al2BA6 1/2" gas x 1/4" liquid PLA-Al8BA6 1/2" gas x 1/4" liquid PLA-A24BA6 5/8" gas x 3/8" liquid PLA-A30BA6 5/8" gas x 3/8" liquid PLA-A36BA6 5/8" gas x 3/8" liquid PLA-A42BA6 5/8" gas x 3/8" liquid PCA Ceiling -suspended PCA-A24KA6 5/8" gas x 3/8" liquid SLZ Ceiling -recessed SLZ-KA09NA 3/8" gas x 1/4" liquid SLZ-KAl2NA 3/8" gas x 1/4" liquid SLZ-KA15NA 1/2" gas x 1/4" liquid SEZ/PEAD Horizontal -ducted SEZ-KD09NA4 3/8" gas x 1/4" liquid SEZ-KD12NA4 3/8" gas x 1/4" liquid SEZ-KD15NA4 1/2" gas x 1/4" liquid SEZ-018NA4 1/2" gas x 1/4" liquid PEAD-A24AA4 5/8" gas x 3/8" liquid PEAD-A30AA4 5/8" gas x 3/8" liquid PEAD-A36AA4 5/8" gas x 3/8" liquid PORT ADAPTERS PART NUMBERS MAC-A454JP-E 3/8" x 1/2" MAC-A455JP-E 1/2" x 3/8" MAC-A456JP-E 1/2" x 5/8" PAC-SG76RJ-E 3/8" x 5/8" PAC-493PL 1/4" x 3/8" 27 MXZ-Series Port Adapters PORT ADAPTER GUIDE MXZ-2B20NA-1 MXZ-3C24NA MXZ-3C30NA MXZ-4C36NA MXZ-5C42NA i MXZ-8C48NA MXZ-2C20NAHZ MXZ-3C24NAHZ MXZ-3C30NAHZ MXZ-4C36NAHZ MXZ-5C42NAHZ MXZ-8C48NAHZ 28 The following MXZ units must utilize at least one branch box MXZ-8C48NA MXZ-4036NAHZ MXZ-5C42NAHZ MXZ-8048NAHZ Branch Boxes Port Gas 1: Liquid A; B; C 3/8" 1: 1/4" A; B; C; D 3/8" 1/4" E 1/2" 1/4" Notes for application: • Check the lineset sizes for your indoor selected models. • Select the branch box or boxes needed for your application. • Compare indoor unit lineset sizes to branch box or outdoor unit port sizes. • Connect 15K + indoor units to the larger 1/2" port on the PAC-AKA50BC branch box or outdoor unit. • Adapt lineset size with appropriate port adapter from above list. • When using the PLA-A24BA6, PEAD-A24AA5, PEAD- A30AA5, PEAD-A36AA5, MSZ-GE24NA two port adapters will be needed 1-MAC-A456JP-E (1/2" x 5/8") or 1-PAC-SG76RJ-E (3/8" x 5/8") and 1 - PAC-493PI (1/4" x 3/8"). 29 M-Series Correction Factors Cooling Capacity Correction Factors MUZ-GE09NA2 MUZ-GE12NA2 Capacity x 1.0 Capacity x 0.954 MUZ-GE15NA2 MUZ-GEI8NA-1 Capacity x 0.878 - MUZ-GE24NA Capacity x 1.0 Capacity x 0.954 Capacity x 0.878 Capacity x 0.771 MUZ-D30NA-1 Capacity x 1.0 Capacity x 0.95 Capacity x 0.878 Capacity x 0.713 MUZ-D36NA-1 MUY-GE09NA2 Capacity x 1.0 Capacity x 0.954 Capacity x 0.878 - MUY-GE12NA2 MUY-GE15NA2 MUY-GEI8NA-1 MUY-GE24NA Capacity x 1.0 Capacity x 0.954 Capacity x 0.878 Capacity x 0.771 MUY-D30NA-1 Capacity x 1.0 Capacity x 0.95 Capacity x 0.878 Capacity x 0.713 MUY-D36NA-1 MUZ-FE09NA-1 Capacity x 1.0 Capacity x 0.945 Capacity x 0.878 - MUZ-FEI2NA-1 MUZ-FE18NA Capacity x 1.0 Capacity x 0.945 Capacity x 0.878 Capacity x 0.771 MUZ-FH09NA Capacity x 1.0 Capacity x 0.945 Capacity x 0.878 - MUZ-FH12NA MUZ-FH15NA Capacity x 1.0 Capacity x 0.945 Capacity x 0.878 Capacity x 0.771 MUZ-FH18NA SUZ-KA09NA Capacity x 1.0 Capacity x 0.954 Capacity x 0.878 - SUZ-KAl2NA SUZ-KA15NA SUZ-KA18NA 30 M-Series Air Outlet Coverage Range* Model Mode MSZ-GEO6NA-9 MSY-GE09NA-9 MSZ-GE09NA-9 MSY-GEI2NA-9 MSZ-GEI2NA-9 HEAT DRY 406 29.5 COOL WET 286 21.0 MSY-GEI5NA-9 MSZ-GEI5NA-9 HEAT DRY 463 33.5 COOL WET 385 28.0 MSY-GEI8NA-9 MSZ-GEI8NA-9 HEAT DRY 512 36.9 COOL WET 385 28.0 MSY-GE24NA MSZ-GE24NA HEAT DRY 738 36.9 COOL WET 661 33.2 MSY-D30NA-8 MSZ-D30NA-8 MSY-D36NA-8 MSZ-D36NA-8 HEAT DRY 848 45.0 COOL WET 763 40.7 MSZ-FE09NA-8 HEAT DRY 381 27.7 COOL WET 307 22.4 MSZ-FEI2NA-8 HEAT DRY 420 30.4 COOL WET 350 25.4 MSZ-FE18NA HEAT DRY 738 36.9 COOL WET 661 33.2 MSZ-FH09NA HEAT DRY 437 29.8 COOL WET 328 22.5 MSZ-FH12NA HEAT DRY 454 31.0 COOL WET 342 23.5 MSZ-FH15NA HEAT DRY 497 33.8 COOL WET 354 24.1 MSZ-FH18NA HEAT DRY 514 23.0 COOL WET 376 16.7 MFZ-KA09NA HEAT DRY 332 15.4 COOL WET 303 14.2 MFZ-KAl2NA HEAT DRY 335 15.6 COOL WET 309 14.5 MFZ-KA18NA HEAT DRY 434 20.0 COOL WET 379 17.5 SLZ-KA09NA HEAT DRY 350 12.1 COOL WET 320 1.1 SLZ-KAl2NA HEAT DRY 390 13.5 COOL WET 350 12.1 SLZ-KA15NA HEAT DRY 390 13.5 COOL WET 350 12.1 `Air coverage represents the distance with one fVsec air speed when blowing out horizontally from the unit operating at the High fan speed. This is only a general guideline; actual coverage depends on size and layout of the room. 31 Heating Capacity Outdoor Temperature 13.0 -4.0 5.0 14.0 23.0 32.0 41.0 50.0 Degrees C F) MSZ/MUZ-FH09NA Heating Capacity 7,303 9,047 10,682 10,900 10,900 10,900 10,900 10,900 (Btu/h) Percentage of 67% 83% 98% 100% 100% 100% 100% 100% Rated Capacity Heating Capacity 91928 11,696 13,600 13,600 13,600 13,600 13,600 13,600 (Btu/h) Percentage of 730/6 86% 100% 100% 100% 100% 100% 100% Rated Capacity Heating Capacity 14,580 16,200 18,000 18,000 18,000 18,000 18,000 18,000 (Btu/h) Percentage of 81% 90% 100% 100% 100% 100% 100% 100% Rated Capacity Heating Capacity 14,210 17,255 20,300 20,300 20,300 20,300 20,300 20,300 (Btu/h) Percentage of 70% 85% 100% 100% 100% 100% 100% 100% Rated Capacity 32 Outdoor Temperature -13.0 -4.0 5.0 14.0 23.0 32.0 41.0 50.0 Degrees( F) r •d Heating Capacity 20,460 21,120 22,000 22,000 22,000 22,000 22,000 22,000 (Btu/h) Percentage of 93% 96 % 100% 100% 100% 100% 100% 100% Rated Capacity [Non -Ducted] Heating Capacity 22,500 23,750 25,000 25,000 25,000 25,000 25,000 25,000 (Btu/h) Percentage of 90% 95% 100% 100% 100% 100% 100% 100% Rated Capacity r r Heating Capacity 25,168 26,884 28,600 28,600 28,600 28,600 28,600 28,600 (Btu/h) Percentage of 88% 94% 100% 100% 100% 100% 100% 100% Rated Capacity Heating Capacity 34,200 39,600 45,000 45,000 45,000 45,000 45,000 45,000 (Btu/h) Percentage of 76% 88% 100% 100% 100% 100% 100% 100% Rated Capacity Heating Capacity 36,480 42,240 48,000 48,000 48,000 48,000 000 48,000 (Btu/h) Percentage of 76% 88 % 100% 100% 100% 100%0 % 100% Rated Capacity ;54,000 Heating Capacity 41,040 47,520 54,000 54,000 54,000 54,000 54,000 (Btu/h) Percentage of 76% 88% 100% 100% 100% 100% 100% 100% Rated Capacity 33 MXZ-Series Accessories BV-Series Ball Valves Al DIAMONDBACK o V� USTED N1N R RIGGERPM � Model numbers: BVI4FFS12 BV12FFS12 BV38FFS12 BV58FFS12 P. Engineered for Mini -split and Multi -split HVAC Units ► Full Port Design ► 700 PSIG Rated = s I Lo/ is1 123 �42 110 �eresr_ .M. s.� zs2 1.e1 111 1.42 1.10 ► R-410A Compatible evlz+siz rz s51 2s/ 1 a1 123 1.4z 1.10 3V58FFSI2 5/8• 6.6� 2.6] 1.81 ^.23 1.42 1 10 ► Flare Connections Forged and machined one Ball valves come with an insulation piece ► piece unibody construction ► Sizes available: 1/4"; 3/8"; 1/2"; 5/8" ► Fully factory assembled. ► Furnace brazed and pressure tested. ► Each ball valve is equipped with 4-1/4" Schrader® valve for refrigerant service. ► Design working pressure: 700 PSIG. ► Temperature range: -40' F to +325° F (-40" C to +149* C). ► Forged and machined brass unibody designed with forged brass seal cap. ► Polytetrafluroethylene (PTFE) seals and gaskets (no synthetic 0-rings). ► Seal cap design permits valve operation without removal of seal cap. ► Uses suitable for with R-11, R-22, R-123, R-125, R-134A, R-236FA, R-4202A, R-40213, R-404A, R-407C, R-410A, R-500, R-502,and R-507. ► One year limited materials and workmanship warranty on ball valves. Platform Stands ��fAMONDBACK" Lift the Mitsubishi Electric Comfort Solution outdoor unit to new heights with our Diamondback Platform Stands. Is easy to install. • Available for all sizes of M- and P-Series outdoor units. • Is color matched to the outdoor units • One-year warcaty. Model Number: DSDn-400N 34 L: 15-3/ x IN: 3-1/4" x H: 3-1/4" M-Series Sizing It is very important that all contractors follow proper procedure and size units based on a Manual J calculation. A load calculation takes into account all the factors that cause the building to lose heat in the winter and gain heat in the summer. Some of the factors taken into consideration are exposed walls, insulation, windows, doors, and even the direction the building faces. Inverter technology has changed the way heat pumps are used. Because the INVERTER -driven compressor can vary the capacity of the system, we can now size units based on the largest load, which in many cases may be the heat load. When single speed compressors are sized on heat load and changed over to cooling, the units can be grossly over -sized. The result is very little dehumidification and comfort problems. Using charts like the ones below from the technical service manual, you can check the equipment capacity at the design temperatures for heating and cooling. If these values fall within both the heating and cooling capacity ranges of the system, you can select that system with confidence. MSZ/MUZ-FHO9NA HEATING CAPACITY Outdoor Tempera- _13.0 -4.0 5.0 14.0 23.0 32.0 41.0 50.0 ture Degrees ( F) Heating Capacity 7,303 9,047 10,682 10,900 10,900 10,900 10,900 10,900 (Btu/h) Percent Heating 67% 83% 98% 100% 100% 100% 100% 100% Capacity COOLING CAPACITY IndcorAir Outdoor intake air DB temperature (" Fj 86 95 104 115 IWB C TC SHC TPC TC SHC TPC TC SHC TPC TC SHC TPC 71 10.3 6.5 0.63 9.7 6.1 0.68 9.0 5.6 0.72 8.3 5.2 0.75 67 9.7 7.4 0.60 9.0 6.8 0.65 8.4 6.4 0.69 7.7 5.8 0.72 63 9.1 8.1 0.58 8.5 7.6 0.62 7.7 6.9 0.66 7.0 6.3 0.69 Notes: IWB: Intake air wet -bulb temperature TC: Total capacity SHC: Sensible heat capacity TPC: Total power consumption (kW) 35 Controllers MHK1 Wireless Remote Controller Kit Exclusive for INVERTER -driven M- and P-Series Systems A�� nccaoe f�, 0 Q� i MRCH1 ■ LIN Wireless Technology Wireless Wall -mounted Remote Controller o. Backlit, easy -to -read display. Dual setpoint control with system changeover. Enabled with RedLINKTm reliability. oInstalls anywhere with simple wall -mounted design. o. Compatible with MCCH1 Portable Central Controller and MOS1 Outside Air Sensor. Requires wireless interface (included in kit). MIFH1 Wireless Receiver o. Required for MRCH1 Wireless Remote Controller. Enabled with RedLINK reliability. 36 Controllers MHK1 Wireless Remote Controller Kit Portable Central Controller P. Up to 16 RedLINKTm devices. .. ► Requires MHK1 per indoor unit. s- ► Monitor and control On/Off, Mode, and Set Temp. ► Schedule override capability. P. Does not interfere with other wireless devices. MCCH1 ► Displays outside air temperature and humidity when used with MOS1. Outside Air Sensor ► Monitors outside air temperature and humidity. ► Displays on MHK1 Wireless Wall -mount Remote Controller and MCCH1 Portable Central Controller. 37 Controllers Thermostat Interface Our Thermostat Interface allows HVAC thermostats or input/output controllers to control Mitsubishi Electric Cooling & Heating commercial or residential indoor units through our CN105 connector. Any indoor unit that can be controlled by MHK1 can now be controlled by a third party HVAC thermostat or input/out controller. This allows Mitsubishi Electric systems to use the capabilities of third party thermostats including but not limited to: Geo-fencing. Automatic scheduling. Humidity control. Set temperature range (dependent on indoor unit) ► Weather forecasting and more. Our patent -pending algorithm allows the outdoor unit's INVERTER - driven compressor to vary its capacity for greater energy savings. The preferred system setup is to use a conventional system control with two stages of heating and cooling (W1, W2, Y1, and Y2). This will provide the most comfort and energy savings. The interface can be setup to accept only one stage of heating and cooling (W1 and Y1). Mitsubishi Electric Thermostat Interface also allows for fan speed control. Third party thermostats or input/output controllers can control the indoor unit's fan speed to three different levels: High, medium, and low. 38 Controllers Specifications ► Allows an HVAC Thermostat or 1/0 Controller to control a Mitsubishi Electric Cooling & Heating [CITY MULTI, M-Series or P-Series] indoor unit. ► One Thermostat Interface per indoor unit. ► Indoor unit modes available: Cool, Heat, Fan, and Off. ► Provides 3 input terminals to control fan speed control: High, Medium, and Low. ► Addressing: No addressing required. ► Connection: CN105 - Active IT Terminal. ► Thermostats Tested: • Nest® • Honeywell® LyricTM • INNCOM° by Honeywell° with High and Low fan speed control. ► Dimensions: (H x W x D) 3.96 in x 3.17 in x 0.93 in. P. Terminal Block: 20-30 VAC Rated. ► Required: Active CN105 on Mitsubishi Electric indoor unit control board. ► Required: HVAC Thermostat or 1/0 Controller (field supplied). ► Required: 24VAC circuit for HVAC Thermostat (field supplied). Advanced Features ► Delayed off adjustable setting. ► Static pressure adjustable setting. P. CN24 operation during defrost. ► Fan speed during thermal off heating mode. ► Two -stage heat and cool thermostat operation. ► Conventional 2h/2c system operation (preferred). P. Conventional 1 h/1 c system operation. P. Auto recovery after power failure. ► Thermostat detects room temperature. 39 Controllers MHK1 Wireless 1] PI Remote Controller Kit s r< 4 4 DescriptionFunction ON/OFF On/Off operation for a single indoor unit Cool / Drying / Auto / Heat / Fan only Available Operation Mode operation modes dependent upon connected system. Temperature Setting Set temperature from 40° F - 99° F depending on operation mode and connected system System Changeover 2° F 8° F Deadband Value Schedule Operation 5-2, 5-1-1 Fan Speed Setting Hi/Mid-2/Mid-1/Low/Auto. Available fan speed settings dependant upon connected system. Airflow angles: 1000 - 800 - 600 - 400 and oscillate. Air Flow Direction Setting Available air flow direction settings dependent upon connected system. Individual prohibit operations for each remote Permit/Prohibit Function controller function (ON/OFF, Set Temperature, and Mode). Space Temperature Displays the measured space temperature. Error Indication Displays error code. Display Outside Temperature Requires optional MOS1 Outside Air Sensor and Humidity Dimensions - (W x D x H) Remote Controller: 5-3/16" x 1-1/2" x 3-9/16" Receiver: 3-1/4" x 1-5/16" x 6-7/16" Operating Ambient Remote Controller: 32 - 120° F Receiver: -40 - Temperature 165° F Operating Ambient Remote Controller: 5 percent - 90 percent RH Humidity (non -condensing) Receiver: 5 percent - 90 /o RH (non -condensing) Power Supply 2 AA batteries (included) 40 Controllers Handheld Wireless Controller Wireless Standard for M-Series wall -mounted and floor -mounted systems and optional for P-Series indoor units Operatic Sele (Heat, Co( Auto, Di Econo Cool Smart SE Butto Reset CI SE Slidi Col Powerful Mode and Wide Vane Control buttons are available on models MSY(2)-GE24/D30/D36NA GE model remote shown, models vary 41 Controllers Wired Controllers Simple MA Controls group operation for up to 16 indoor units in a single group ► Supports both Fahrenheit and Celsius. ► User defined functions: • ON/OFF. • Operation mode: AUTO (R2-Series only), COOL, HEAT, FAN, DRYING, or SETBACK. 33 r. . Set temperature. • Fan speed setting. • Air flow direction. rlj� •w�[ • Set temperature range: 40' F - 95' F depending on operation mode and indoor unit connected. ► Set temperature range limit can be reduced for cool and heat modes. ► LOSSNAY®: Simple MA for interlocked system can set high/low/ Stop on LOSSNAY. ► Room temperature can be sensed either at the indoor unit (default) or at the remote controller. ► Diagnostics: Displays four -digit error code and error unit address. ► Grouping: Same group use only with other PAC-YT53CRAU Simple MA Controllers, PAR-31 MAA Wired MA Remote Controllers, and PAR-FUA32MA Wireless MA Remote Controllers with up to two remote controllers per group. ► Addressing: No addressing required. ► Wiring: connects using two -wire, stranded, non -polar control wire to indoor unit connection terminal or control adapter (MAC-3331F for M-Series) requires crossover wiring for indoor unit grouping. ► Dimensions: 2-3/4" x 9/16" x 4-3/4" (70mm x 14.5mm x 120mm). 42 Controllers Wired Controllers Wired MA 28.5r 24.0r. �__.M now� Controls group operation for up to 16 indoor units in a single group ► Features selectable multi- lingual LCD (English, Spanish, and French). User functions allow user to set: ► Timer Operation: • Weekly Timer: On/Off/ Temperature setting up to 8 times per day of the week in 1-minute increments. • Simple Timer: On and Off time can be set once within 72-hour period in 1-hour increments. • Auto -off Timer: Turns indoor unit Off based on countdown time up to 4-hours in 30-minute increments. ► Room Temperature: Displays room temperature sensed either at the indoor unit (default) or at the remote controler. ► Set Temperature Range Limit: From the Backlit MA Controller, the allowable set temperature range can be reduced for cool and heat modes. ► Special Function Rotation/ Backup (Lead/Lag for P-Series). P. Static pressure setting (model dependent) P. Fan speed setting for use with supplemental heating function (model dependent). ► Function Lock Out: Prohibits all functions or all functions except On/Off from the backlit MA controller. P. Wiring: connects using two - wire, stranded, non -polar control wire to indoor unit connection terminal or control adapter (MAC-3331F for M-Series) requires crossover wiring for indoor unit grouping. ► Dimensions: 4-3/4" x 3/4" x 4-3/4" (120mm x 19mm x 120 mm) 43 P-Series Indoor Units Connect to cooling -only PUY and heat pump PUZ INVERTER -driven compressor outdoor units. PKA Wall -mounted Series Cooling -only and Heat Pumps (12,000 to 34,200 Btulh) ► Provides cooling and heating in a wide range of capacities. ► Auto flap shutter. ► Auto fan control. ► Easy -clean washable filters. ► Multiple controller options. PCA Ceiling -suspended Series Cooling -only and Heat Pumps (24,000 to 42,000 Btulh) ► i-seeTM Sensor optional. ► Knockout for ventilation air. P. Auto fan speed control. ®%�e �. • ►ii Optional, high -efficiency filter. ---' 3 ► Multiple controller options. PLA Ceiling -recessed Series Cooling -only and Heat Pumps (12,000 to 42,000 Btulh) ► Built-in condensate lift mechanism (33" lift). ► Branch duct outlet. ► i-seeTM Sensor optional. ► Knockout for ventilation air. ► Multiple controller options. 44 __a + __ ?,. a 1� � PVA Multi -position Air Handling Units Provides cooling and heating to larger zones (18,000 to 42,000 Btu/h) ► Performance: One inch foam R4.2, fiberglass -free insulation reduces condensation and boosts efficiency. P. Quality: durable, powder 38e coated cabinet. _V � �"� P.Serviceability: easily removable 7 � a fan provides access for coil cleaning. P.Flexibility: true multi -position, requiring no additional kits for downflow configuration. ► Installation: quality construction with disassembly in mind to make fitting through tight access points simple. ► Comfort: DC motor ensures quiet and efficient operation year round. ► Low Impact: fully RoHS compliant to reduce carbon footprint. ► Air Quality: positively pressurized cabinet and tested air leakage less than 1 %. PEA/PEAD Horizontal Ducted Series Cooling -only and Heat Pumps (12,000 to 42,000 Btu/h) W ► Automatic fan speed control. P. Built-in condensate lift mechanism (21 11/16" PEA, 27 9/16" PEAD lift). ► Adjustable static pressure. ► Multiple controller options. _ "zee :• � ! L:�l P-Series Systems Specifications (Cooling Only) Indoor Unit Model # Outdoor Unit Model # Cooling Capacity Range (Btu/h) 6,000-12,000 8,000-18,000 12,000-24,000 SEER Range 14.0-15.2 14.2-15.3 14.0-17.0 Lineset Size 1/4" x 1/2" 1/4" x 1/2" 3/8" x 5/8" (Liquid x Gas) Lineset Length/Height Max 1657100' 1657100' 225A 00' Separation Test conditions are based on AHRI 210/240. ► i Seacoast Protection Coating ► P-Series models 12K-36K Btu/h are pre -charged for up to a 70' line set. PUY/Z-A42NHA5 and H2i models are pre -charged for up to a 100' line set. 46 PEAD-A30AA5 PEAD-A36AA5 PEAD-A42AA5 PKA-A30KA6 PKA-A36KA6 PLA-A42BA6 PLA-A30BA6 PLA-A36BA6 PCA-A42KA6 PCA-A30KA6 PCA-A36KA6 PUY-A30NHA6(-BS) I PUY-A36NHA6(-BS) I PUY-A42NHA6(-BS) P-Series Systems Specifications (Heat Pump) Indoor Unit Modelq i r., r , r Outdoor Unit Model q Cooling Capacity 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 Range (Btu/h) Heating Capacity 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 Range (Btu/H) SEER/ 14.2-15.3/ 14.0-17.0/ 14.0-15.5/ 14.0-15.0/ HSPF Range 9.5-10.0 8.5-10.9 8.7-9.4 9.3-10.2 Lineset Size (Liquid x Gas) 1/4" x 1/2" 3/8" x 5/8" 3/8" x 5/8" 3/8" x 5/8" Lineset Length/ Height Max 1001/100, 165'/100' 1657100' 165'/100' Separation Test conditions are based on AHRI 210/240. BS= Seacoast Protection Coating P-Series models 12K-36K Btu/h are pre -charged for up to a 70' line set. PUY/Z-A42NHA6 and 1­12i models are pre -charged for up to a 100' line set. 48 (2)PEA-Al 8AA6 PEAD-A30AA5 PEAD-A36AA5 PEAD-A42AA5 PEAD-A42AA5 PKA-A30KA6 PKA-A36KA6 PKA A42KA6 PLA-A42BA6 PLA-A30BA6 PLA-A36BA6 PLA-A42BA6 PCA-A42KA6 PCA-A30KA6 PCA-A36KA6 PCA-A42KA6 PVA-A30AA4 PVA-A36AA4 PVA-A42AA4 PUZ-A42NHA6 (-BS) PUZ-HA30NHA6 PUZ-HA36NHA6 PUZ-HA42NKA P-Series Systems Correction Factors Cooling Capacity Correction Factor (x capacity) PUY-Al2/18NHA6 PUZ-A18NHA6 1.00 0.985 0.948 0.916 0.886 0.859 PUY-A24-36NHA6 PUZ-A24-36NHA6 1.00 0.988 0.964 0.938 0.915 0.893 PUY-A42NHA6 PUZ-A42NHA6 1.00 0.985 0.948 0.916 0.886 0.859 Hyper -Heating INVERTER (H2i®) Cooling Capacity Correction Factors (x capacity) PUZ-HA30NHA6 PUZ-HA36NHA6 1.00 0.985 0.957 0.931 0.908 PUZ-HA42NKA Heating Capacity Correction Factors (x capacity) PUZ-HA30NHA6 PUZ-HA36NHA6 1.00 0.997 0.991 0.985 0.979 PUZ-HA42NKA s0 Heating Capacity Correction Factors (x capacity) 165 ft Refrigerant 180 ft230 piping length (one way) 260 ft ift Eft 260 ft 165 ft Refrigerant 180 ft piping length (one 195 ft way) 230 ft N® r• r .• . 51 P-Series Air Coverage Range Outlet Air Speed and Coverage Range* Model PLA-Al2BA6 530 8.5 13 PLA-Al8BA6 640 10.5 15 PLA-A24BA6 640 10.5 15 PLA-A30BA6 740 12.1 18 PLA-A36BA6 1060 17.4 26 PLA-A42BA6 1090 17.7 26 PKA-Al2HA6 425 20.0 35 PKA-Al8HA6 425 20.0 35 PKA-A24KA6 775 19.7 47 PKA-A30KA6 775 19.7 47 PKA-A36KA6 920 22.3 53 PCA-A24KA6 670 10.2 32 PCA-A30KA6 705 10.5 33 PCA-A36KA6 990 11.8 41 PCA-A42 KA6 1,025 12.1 42 *A r coverage represents the distance with 0.8 f /sec air speed when blowing out horizontally from the unit operating at the High fan speed. This is a general guideline; actual coverage depends on size and layout of the room. 52 Installation Required Tools for Installation • Phillips screwdriver. • Micron gauge. • Pipe cutter with reamer. • 3" (75mm) hole saw. • Level. • Charge hose for R410A. • Flaring tool. • 1/4" - 5/8" torque wrench. • Scale. • Gauge manifold for R410A. • Nitrogen. • 5/32" (4mm) hexagonal wrench. • Utility knife or scissors. • Adjustable wrenches. • Vacuum pump. Condensate Drain Pipe Installation Yes: No: �' � �• Tq0 to PVC dmn T. 1J)IAAI 'r 53 M-Series Wall -mounted System Clearances za/8" or more/ 4" or in for left left ba, Piping u, space Applies to all M-Series models except MXZ-8C48NA. Check installation instructions for your exact model. 54 P-Series Outdoor System Clearances To illustrate the minimum space required around the outdoor unit, the clearances for all P-Series models are shown below. See installation manual for the minimum clearances by model. 3-15/16"or more if no obstacle is placed at the rear or right or left side of the unit 13-25132" *2 �VV 39-3/8" 5-29/32" 2 sides should be open in the right, left and rear side. Minimum installation space for outdoor unit "1. In a place where short cycling can occur, cooling and heating capacity will decrease and power consumption will increase by 10 percent. Air outlet guide (PAC-SG58SG-E for PUY/PUZ-Al2/18NHA or PAC-SG59SG-E for PUY/PUZ-A124/30/42NHA) will help improve capacity. '2. If air is discharged onto a wall, the surface may discolor. 55 Installation Refrigerant Piping Installing Refrigerant Piping For 'Twinning" indoor units for better airflow coverage in a large or L-shaped room (For A24/A36, and HA36 outdoor units only). Refrigerant piping limitations of length and height difference are shown in the figure below. Max. length, PUY/PUZ-A24/36NHA systems: a1+a2+bs165ft Max. length, PUZ-HA36NHA hyper -heating systems: a1 +a2+b<245ft Key: A = Indoor unit B = Outdoor unit C = Multi distribution pipe (option) d = Height difference (Indoor unit -Outdoor unit) Max. 100 ft. e = Height difference (Indoor unit -Indoor unit) Max. 3 ft. 56 How to Check for Refrigerant Restriction: 1. Verify the refrigerant charge. • Remove the charge and weigh it back in. • Make sure the system has the refrigerant amount specified for the line length (see Service Manual). 2. Measure for temperature differences across evaporator. • Set unit operation to cooling and change temperature set point to lowest degree available, or switch system to emergency COOL mode. • Change fan operation to high speed. • Run system for five minutes, and then measure both the entering and leaving air temperatures with a thermometer. • The temperature differential should be around 20° F to 23° F (see Service Manual). • Remove the charge and weigh it back in. • Make sure the system has the refrigerant amount specified for the line length (see Service Manual). Assuming you have verified the charge, a difference of less than 20' F means the system is restricted. A difference of 23° F or more usually means low airflow, often because dirt has built up on the fan blades. Clean the fan and coil and check temperatures again. Note: When testing the system, remember to change the fan operation to high speed and verify that the unit is charged with the proper amount of refrigerant. 57 Installation Wiring: M-Series and P-Series P. Indoor unit power is supplied from the outdoor unit. ► On M-Series models, use AWG-14-3 600 VAC -rated copper wiring between outdoor unit and indoor unit for high voltage and controls circuits. ► On P-Series models, use AWG-16-3 600 VAC -rated copper wiring between outdoor unit and indoor unit for high voltage and controls circuits. ► If larger gauge wiring is required by code - use that on S1 and S2 terminals while using proper wire size on S3 communication terminal (16 gauge on P-Series and 14 gauge on M-Series). ► Two types of connection patterns, for 1:1 system and for P-Series "twin" operation ("twinning") are shown in the diagrams at right. Key: A = Outdoor unit power supply B = Wiring circuit breaker or isolating switch C = Outdoor unit D = Indoor unit/Outdoor unit connecting wiring E = Remote control F = Indoor unit Note: All wiring shall comply with NEC and local electrical codes. See unit installation manual for details. 58 INDOOR UNIT Notes: Terminal Block Ground ' A disconnect Terminal switch may be required at F sz ss indoor unit. '* Use a ring tongue terminal 'TAZ-MS303 if AWG12 wire 3 Pole Disconnect 00 is used. 208/230V AC DC Control 1 Phase, 60 Hz Circuit 12-24V DC Power Supply 1J a si sz ss 208/230V AC Ground rz 1 Phase, 60 Hz Terminal OUTDOOR UNIT "Twinning" Operation Power Supply 208/230V AC C 208/230V AC F F L1 E 1 01 A B 1-2 2 02 GR S2 S2 S2� S3 S3 S3 1 'TAZ-MS303 _ 1 D 12-24V DC 59 Installation Test Run 1. Turn power on to outdoor unit. 2. Press the emergency operation button once. The test will run for 30 minutes. If E115--i the LED light blinks every 0.5 seconds, verify the indoor/outdoor connecting wire Emergency operation switch is installed properly. After the test run, the (E.O. SW) emergency COOL mode (75' F) will operate. 3. To stop operation, press the emergency operation button several times until all LED lights turn off. See operation manual for details. Checking the Remote (Infrared) Signal Reception 1. Press the ON/OFF button on the remote controller and listen for a beep from the indoor unit. 2. Press the ON/OFF button again to turn the air conditioner off. 3. After the compressor stops in the outdoor unit, the restart prevention device will activate. This causes the compressor to stop operation for three minutes, which protects the air conditioner. Caution: After finishing the test run or checking the remote (infrared) signal reception, use emergency operation button or remote controller to turn unit off before turning power supply off. If this sequence is not followed properly, the unit will start operating automatically when the power supply resumes. Need Help When You Are On The Jobsite? Check out www.mylinkdrive.com Here you can find: service bulletins, FAQs, Guide Specs, Install Manuals, MSDS sheets, Operation Manuals, Parts Lists, Service Manuals, Submittals, Accessories and the M&P troubleshooter. 60 Auto Restart Function: Mitsubishi Electric systems are equipped with an auto restart function. If the power shuts off while the system is operating (blackouts, etc.), the system will automatically resume operation at the previous setting after the power resumes. If the end user prefers not to use this function, a service representative can deactivate it. See Operation Manual for details. Necessary End User Information: After installation, show the end user how to operate the system remote controller and remote controller holder, remove the air filter, cleaning methods, operating precautions, etc. Recommend that the end user read the Operation Manual. Continuous Fan Operation: Explain to the end user that the indoor unit fan is designed to continuously run air across the filters. A sensor also constantly measures room temperature to maintain set point. These functions help improve air quality and reduce wear and tear on the fan motor. 61 Ducting Considerations Ducting Considerations for the PEA/PEAD/SEZ Horizontal Ducted Indoor Unit Considering the performance and design of these indoor units, selection and proper duct sizing and installation are necessary for satisfactory operation. The maximum available static pressure from the PEA and SEZ indoor units is 0.2 in. W.G. and for the PEAD indoor units 0.6 in. W.G. Most of the static pressure duct loss comes from allowing the duct work to sag. Allowing even a 30 percent sag in the ductwork can increase the static pressure loss up to eight times. Flexible ductwork runs should be kept to less than 15 ft. Airflow (CFM) 50 100 150 200 250 Grille Size (In. x In.) 6x6 6x6 8x6 10x6, 8x8 12410x8 Inches of Static Pressure Loss per 100 ft. of hard duct 4" 0 6" 0 8" 0 10"0 50 CFM 0.15 0.02 - 100 CFM 0.6 0.08 0.02 150 CFM - 0.2 0.04 - 200 CFM 0.3 0.08 0.02 250 CFM 0.45 0.11 0.04 500 CFM - 0.4 0.15 62 LIMITED WARRANTY INFORMATION AlkMITSUBISHI ELECTRIC Effective APRIL, 2015 M-Series Warranty: P. 12-year parts and 12-year compressor warranty is available to the original owner provided the system is: • Installed by a Diamond Contractor in a residential single-family owner -occupied home. • Registered by the installing contractor through the Extranet within 90 days of installation. ► 10-year parts and 10-year compressor warranty is available to the original owner provided the system is: • Installed by a licensed contractor in a residential single-family owner -occupied home. • Registered through the MitsubishiComfort.com site, within 90 days of installation. P. 5-year parts and 7-year compressor warranty will come standard to the original owner. P-Series Warranty: ► 12-year parts and 12-year compressor warranty is available to the original owner provided the system is: • Installed by a Diamond Contractor in a residential single-family owner -occupied home. • Registered through the Extranet within 90 days of installation. P. 10-year parts and 10-year compressor warranty is available to the original owner provided the system is: • Installed by a licensed contractor in a residential single-family or commercial application. • Registered through the MitsubishiComfort.com site within 90 days of installation. ► 5-year parts and 7-year compressor warranty will come standard to the original owner. The full text of this Limited Warranty is available on the Mitsubishi Electric website, The Limited Warranty gives the owner specific legal rights and the owner may also have other rights that vary from state to state. Some states do not allow limitations on warranties or exclusions or limitation of damages, so the specified limitations or exclusions may not apply. This Limited Warranty Is valid only in the continental United States, Alaska and Hawaii and is not transferable. For more information, contact. Customer Care: 800-433-4822 Web: http://www.mitsubishipro.com 63 Synchrony Financing Getting Started is as Easy as 1,2,3! Go to toolbox and take selling strategies: ► toolbox. mysynchrony.com/diamondEnroll. ► Download the rate menu for available plans. P. Follow the Commitments guide focusing on getting team trained Download this Synchrony Contacts flier for training and more information. Think Outside the Toolbox! Announcing the Selling In The Home Webinar Training Series What if you worked as hard on your business as you work in your business? You use your knowledge and skill to choose the right tool for the job. So why not put that same sharp focus to work growing your business? Synchrony Financial is excited to invite you to Think Outside the Toolbox —a website dedicated to helping you grow your business by closing more projects. As part of our commitment to bringing you useful tools and fresh ideas, we've leveraged insights from our largest partners in the Home Improvement, HVAC, Spa and Landscape industries, and combined them with Synchrony Financial's expertise. In addition, Synchrony Financial teamed up with Dave Yoho Associates to develop the materials in theSelling In The Homewebinar series. We invite you to take advantage of all this knowledge and experience today. 64 Take the first step toward growing your business by visiting our Think Outside the Toolbox website at: toolbox.mysynchrony.com/diamond Once there, you will complete a quick site registration and be offered two series of training webinars. Each webinar training series consists of two 15-20 minute webinars, and two short quizzes. In the Selling In The Home webinar series you will learn: ► The critical role of consumer financing throughout the sales process. ► Common myths about financing. ► How to set a good first impression with the customer. ► Tips on how to present your company and products. ► How to close the sale leveraging special promotional financing options. Receive a $25 Visa® Gift Card' for completing each webinar training series and corresponding quizzes. 65 MITSUBISHI 1 /_ ELECTRIC MAKE COMFORT nQp�O►1C11 COOLING & HEATING v Mitsubishi Electric, H21, CITY MULTI, Lossnay and the three diamond logo are registered trademarks of Mitsubishi Electric Corporation, Lyric, Inncom and RedLlnk are trademarks of Honeywell Corporation. Nest is a trademark of Google, Inc. Use of the AHRI CertifiedTM Indicates a manufacturer's participation in the certification program. For verification of certification for individual products, go to www.ahridirectory.org. See complete warranty for terms, conditions, and limitations. A copy is available from: Mitsubishi Electric, 1340 Satellite Blvd, Suwanee, GA 30024 Specifications subject to change without notice. For more information visit www.mehvac.com T J,� onslerfrom f�,g c�1�. FSC rasa nia &oGroas T FSC® C009723 Intertek MQR 10.2015 REVISED SKU: MQR0710_V1 Customer Care: 800-433-4822 1 Printed In The U.S.A 02015 Mitsubishi ElectricUS, Inc.