Loading...
APPROVED BLD RESUB1 BLD2023-1499+Architectural_Plan+2.16.2024_3.50.31_PM+4066108ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE ■ ■ Hardware and fasteners in contact with I preservative -treated wood shall be of ■ hot -dipped zinc galvanized steel, I I stainless steel, silicon bronze or copper. ■ • In the absence of manufacturers I I recommendations a minimum of ASTM A 653 type G185 zinc -coated galvanized steel, or I I equivalent, shall be used. ■ ■ I RC R317.3.1 IBC 2304.10.5.1 I See Geotech report for pin pile requirements. If pin piles are to be installed. Installation shall be monitored by Geo or an approved third party inspection service. If welding is to be performed on -site, the welding shall be performed by a WABO certified welder and inspected by a WABO certified inspector. Reports shall be provided to the city inspector prior to approval of footings City Of Edmonds Building Department Work DECK Address 215 10TH PL N Owner FERRIS Approved Date Building Official Permit Number BLD2023-1499 r v�. FARIS PROJECT JOHN FARIS 215 loth PL N Edmonds, WA 98020 A101 COVER PAGE A101.1 SITEPLAN A101.2 SIMPLIFIED PLANS A102.3 DECK PLAN A102.4 DECK FRAMING PLAN A103 FOUNDATION PLAN A104 DETAILS A105 RENDERINGS & GENERAL NOTES A106 BUILDING ELEVATIONS GENERAL FRAMING NOTES FRAMING NOTES: -ALL WORK TO CONFORM TO CURRENT BUILDING CODE • 2018 INTERNATIONAL BUILDING CODE • 2018 INTERNATIONAL RESIDENTIAL CODE • 2018 WASHINGTON STATE AMENDMENTS -ALL FRAMING MEMBERS TO BE PRESSURE TREATED HEM -FIR #2 OR BETTER UNLESS NOTED OTHERWISE ON PLANS -ALL GLULAM BEAMS EXPOSED TO MOISTURE AND INDICATED ON THE PLANS AS "GLB-HICLEAR" SHALL BE PRESERVATIVE TREATED "HI -CLEAR II" GRADE 24F-V4 BEAMS AS MANUFACTURED BY ROSBORO, INC. FASTENER NOTE: -I.R.C. 317.3 FASTENERS FOR PRESSURE TREATED PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER -SIMPSON "SDWS" TIMBER SCREWS SHALL BE INSTALLED PER MANUFACTURES TECHNICAL BULLETIN AND UES EVALUATION REPORT # 192 -"SIMPSON MPB66Z" POST BASE BRACKETS (WHEN SPECIFIED) SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS IN THE LATEST 'WOOD CONSTRUCTION CONNECTORS' CATALOG BY SIMPSON STRONG -TIE, INC. DECK PLAN 3/8" = 1'-0" FLOOR NOTES 36" HIGH ALUMINUM POST & RAILS WITH PICKET GUARD -RAILING SEE 2/A104 FOR GUARD POST CONNECTION (TYP) DECKING MATERIAL "TIMBERTECH" COMPOSITE MATERIAL/PRODUCT MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N O 00 1■■1 � M Q z Q LL. U) J 3: M �--� � r Q�-0 M LL_O C: zT--i o N = Ln E -0 O r' N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:42 AM DRAWN BY: Author SCALE: 3/8" = V-0" PARCEL NO: PARCEL LEGAL LEGAL ypGAN OF W ASHN� OF CISTERE� \� FSS/ONALE2/12/2024 DECK PLAN A1023 GENERAL FRAMING NOTES FRAMING NOTES: -ALL WORK TO CONFORM TO CURRENT BUILDING CODE • 2018 INTERNATIONAL BUILDING CODE • 2018 INTERNATIONAL RESIDENTIAL CODE • 2018 WASHINGTON STATE AMENDMENTS -ALL FRAMING MEMBERS TO BE PRESSURE TREATED HEM -FIR #2 OR BETTER UNLESS NOTED OTHERWISE ON PLANS -ALL GLULAM BEAMS EXPOSED TO MOISTURE AND INDICATED ON THE PLANS AS "GLB-HICLEAR" SHALL BE PRESERVATIVE TREATED "HI -CLEAR II" GRADE 24F-V4 BEAMS AS MANUFACTURED BY ROSBORO, INC. FASTENER NOTE: -I.R.C. 317.3 FASTENERS FOR PRESSURE TREATED PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER -SIMPSON "SDWS" TIMBER SCREWS SHALL BE INSTALLED PER MANUFACTURES TECHNICAL BULLETIN AND UES EVALUATION REPORT # 192 -"SIMPSON MPB66Z" POST BASE BRACKETS (WHEN SPECIFIED) SHALL BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS IN THE LATEST 'WOOD CONSTRUCTION CONNECTORS' CATALOG BY SIMPSON STRONG -TIE, INC. (4) SDWH FASTENERS PER BAY LUS28-2 AS REQUIRED (TYP) LUS28 AS REQUIRED (TYP) SIMPSON DTT1Z MIN (8 LOCATIONS) 2X10 HF #2 LEDGER BOARD W/ (4) SDWH PER BAY STAGGERED TOP AND BOTTOM LINE OF EXISTING WALL BELOW 2X BLOCKING AT BEAM LINE 6x6 HF#2 POSTS (TYP) x5 X-BRACING PER 3/A104 4x4 HF#2 POSTS (TYP) x8 2x12"STAIR STRINGER @ 12" O.C. DECK FRAMING PLAN 3/8" = 1'-0" FLOOR NOTES 36" HIGH ALUMINUM POST & RAILS WITH PICKET GUARD -RAILING SEE 2/A104 FOR GUARD POST CONNECTION (TYP) SINGLE KNEE BRACE PER 5/A104 DECKING MATERIAL "TIMBERTECH" COMPOSITE MATERIAL/PRODUCT MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N O 00 1■■1 � M Q z Q U , J 3: M I-1 � r Q�_0 M LL_O C: zT--i O N = Ln E -0 O r' N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:43 AM DRAWN BY: Author SCALE: 3/8" = V-0" PARCEL NO: PARCEL LEGAL LEGAL ypGAN WASH�� 57648 OF CISTERE� \� FSS/ONALE2/12/2024 DECK FRAMING PLAN A102n4 P.T. 6X6 POST SIMPSON POST BASE SEE PLAN TOP OF FINISHED GRADE 0 c 1 as o IF, iH BATTERED PILE, ANGLE DOWN SLOPE (SEE PLAN FOR LOCATIONS) PIN PILE DETAIL 1 /2" = 1'-011 PIN PILE NOTES: 1. CONSTRUCT FOOTING AND PILES PER COBALT GEOTECHNICAL REPORT (1/8/2024) 2. PILE IS NOT TO EXCEED 30 ft. 3. PILE CAPACITY IS 6,000 lbs. 4. REFUSAL CRITERIA IS 3 CYCLES OF 60 INCHES PER SECOND. 10" DIAMETER CONCRETE PLINTH. DOWEL INTO FOOTING W/ (4)#4 BARS) CONCRETE FOOTING PER PLAN EMBED 6" INTO FOOTING AND PROVIDE WELDED 4" DIA CAP PLATE I I BOTTOM OF FOOTING MIN 18" BELOW GRADE 5 1 #4 BARS EACH WAY PER PLAN 2" DIA SCH 80 PIPE DRIVEN TO REFUSAL (CENTER ON FOOTING WHERE ONLY ONE PILE IS USED) P.T. 6X6 POST SIMPSON POST BASE SEE PLAN TOP OF FINISHED GRADE PIN PILE DETAIL 1 /2" = 1'-0" LINE OF EXISTING WALL ABOVE 10" DIAMETER CONCRETE PLINTH DOWEL INTO FOOTING W/ (4)#4 BARS) CONCRETE FOOTING PER PLAN EMBED 6" INTO FOOTING AND o PROVIDE WELDED 4" DIA CAP PLATE 1d 11. e o r BOTTOM OF FOOTING MIN 18" BELOW GRADE #4 BARS EACH WAY PER PLAN \ 2" DIA SCH 80 PIPE DRIVEN TO REFUSAL (CENTER ON FOOTING) GENERAL FRAMING NOTES FRAMING NOTES: -ALL WORK TO CONFORM TO CURRENT BUILDING CODE • 2018 INTERNATIONAL BUILDING CODE • 2018 INTERNATIONAL RESIDENTIAL CODE • 2018 WASHINGTON STATE AMENDMENTS FASTENER NOTE: -I.R.C. 317.3 FASTENERS FOR PRESSURE TREATED PRESERVATIVE AND FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER -SIMPSON 11SDWS" TIMBER SCREWS SHALL BE INSTALLED PER MANUFACTURES TECHNICAL BULLETIN AND LIES EVALUATION REPORT # 192 LOOTING SCHEDULE] F-1 DECK FOUNDATIONAL FOOTING PER 1/A103 36" x 36" SQ REINF W/ (4)#4 BARS EACH WAY F-2 DECK FOUNDATIONAL FOOTING PER 2/A103 22" x 22" SO REINF W/ M#4 BARS EACH WAY See Geotech report for pin pile requirements. If pin piles are to be installed. Installation shall be monitored by Geo or an approved third party inspection service. If welding is to be performed on -site, the welding shall be performed by a WABO certified welder and inspected by a WABO certified inspector. Reports shall be provided to the city inspector prior to approval of footings SHED STING MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N MO W N � M Q z Q LL. U) J 3: M I--1 � a— Q IZ- 4—J Cn -0 M LL_O C: zT--i o N = Ln E -0 O r' N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:45 AM DRAWN BY: Author SCALE: As indicated PARCEL NO: PARCEL LEGAL LEGAL ypGAN WASH�� 57648 OF CISTERE� \� FSS/ONALE2/12/2024 FOUNDATION PLAN FOUNDATION PLAN A103 3/8" = 1'-0" Z_ Zh PICKET RAILING ELEVATION 1 /2" = 1'-0" TOP CAP POST ALUMINUM PICKET 4" BALL MAY NOT PASS THROUGH DECKING FRAMING PER PLAN OUTSIDE RIM JOIST LADDER BLOCK @ 1611O.C. FLUSH AT TOP OF JOIST OUTSIDE RIM JOIST LADDER BLOCK @ 16"O.C. FLUSH AT TOP OF JOIST JOISTS LEDGER MIN P.T. 2x8 JOIST (8) #14 SCREWS EACH END SECTION B-B GUARDRAIL POST CONNECTION 1 /2" = 1'-0" SINGLE BOARD BORDER n' _ z 1 /0" -SPACING PER BLOCK / AN i C\.J 2x8 MIN RIM JOIST 5"x5"x3/8" MOUNTING PLATE (4) 3/8"x6" GALV. OR SS LAG SCREW PRE -DRILLED WITH 1/4" PILOT HOLES AND SOAP THREADS 6x6 BLOCKING BETWEEN JOISTS. A34 OR A35 HANGER FOR CONNECTION TO RIM JOIST RAILING POST DECKING 0'-8" — OUTSIDE RIM JOIST SIDE VIEW LADDER BLOCK @ 16"O.C. FLUSH AT TOP OF JOIST DOUBLE BOARD BORDER RIM JOIST (END OF DECK) 2x6 FLAT BLOCK FLUSH TO TOP OF JOIST TO SUPPORT BORDER RIM JOIST 1'- 1 1/2" OUTSIDE RIM JOIST SIDE VIEW LADDER BLOCK @ 16"O.C. FLUSH AT TOP OF JOIST TOP VIEW SECTION A -A X-BRACING DETAIL 1 /2" = 1'-0" P/T WOOD BEAM SEE FRAMING PLAN CORROSION RESISTANT METAL COLUMN CAP INSTALL PER MFR (SIMPSON HANGER, MATCH PER BEAM SIZE) SINGLE KNEE -BRACE DETAIL I CIT CT C` -R EXISTING R NG PER DECK .� GIST (E) FINISHED FLOOR AND HOUSE JOISTS 4" SDWS EXTERIOR GRADE TIMBER SCREWS PER PLAN SEE FRAMING NOTES FOR INSTALL SPECS. P/T POST PER PLAN EACH 2X4 RUNS OPPOSITE FACE OF THE POSTS OPTIONAL: ADD P/T 4X4 BLOCK AT CENTER POINT OF BRACING W/ (2) 10d EACH SIDE P/T 2X4 HF#2 (4) 10d (2) STAGGERED SIMPSON "SDWH" TIMBER SCREWS, EMBEDED 3.5" MIN. INTO POST AND COUNTERSINK TO KNEE -BRACE (TYP) 4x4 P/T HEM FIR #2 KNEE -BRACE P/T DECK POST SEE FRAMING PLAN BAR FLASHING IMPSON JOIST ANGERS PER PLAN ECKING PLANKS. SEE PLAN OR TYPE AND SIZE DISTS PER PLAN TT1Z W/6-SD #9X1-1/2" CREWS TO DECK JOIST @ 8" O.C. IMPSON "SDWH" TIMBER CREW, EMBEDED 3" TO HOUSE WALL BOTTOM PLATE OR 2x WALL STUD MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N O � 00 1■■1 � � Q z Q U. J M I —I � a— Q 4 J M LL O C: zT-1 O N =Ln E 0 0 � N W Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:47 AM DRAWN BY: Author SCALE: As indicated PARCEL NO: PARCEL LEGAL LEGAL ypGAN WgSH1� 57648 OF FCISTERE� \� FSS/ONAL2/12/2024 DETAILS n BORDER BLOCKING DETAIL LEDGER CONNECTION DETAIL U 3/4" = 1'-0" A104 TYPICAL STAIR AT DECK DETAIL SIDE VIEW DECK RIM PT. BLOCK 2x6 MIN. SIMPSON "LSCZ" STRINGER CONNECTORS TING STAIRS STAIR AT DECK DETAIL 1 /2" = 1'-0" STAIR AT LANDING DETAIL SIDE VIEW STAIR AT LANDING DETAIL 1 /2" = 1'-0" NOTCH STAIR JACK A34 �_]f_MIza►[09*_5 HANDRAILS ON STEPS TO HAVE ENDS RETURNED AND PLACED MIN. 34" MAX. 38" ABOVE STEP NOSING. THE HAND GRIP PORTION OF HANDRAIL SHALL NOT BE LESS THAN 1-1/2" NOR MORE THAN 2" IN CROSS -SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. THE HANDGRIP PORTION OF HANDRAILS SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. RAILING SHALL NOT PASS A 4" SPHERE. THERE SHALL BE NO MORE THAN 3/8" VARIANCE BETWEEN THE TALLEST RISER AND THE SHORTEST RISER ON ANY FLIGHT OF STEPS. SIMPSON "LSCZ" STRINGER CONNECTORS FASTEN STAIR BRACKET PLATE TO DECK RIM JOIST W/ SIMPSON "TJC37" FLAT PLATE BTWN EACH STRINGER (MIN 2) TYPICAL STAIR AT DECK DETAIL SIDE VIEW J DECK RIM PT. BLOCK 2x6 MIN. SIMPSON "LSCZ" STRINGER CONNECTORS 2L (MD) STAIR LANDING FRAMING DETAILS —� 1 /2" = 1'-011 STAIR LANDING IN DIRT DETAIL FRONT VIEW CONCRETE FOOTING: IF LANDING ON CEMENT SUBSTITUTE APT 2x6 FLAT WHERE 4x4 IS. (PIN TO CEMENT) STAIR LANDING IN DIRT DETAIL 1 /2" = 1'-0" RAIL 4X4 STAIR JACK LEDGER LOCK EPB44 OPEN GUARDS ON DECKS MORE THAN 30" ABOVE GRADE OR FLOOR BELOW SHALL HAVE MEMBERS SPACED SO THAT A 4" DIA. SPHERE CANNOT PASS THROUGH. -10" MIN RUN FROM NOSING TO NOSING STAIRWAY NOTES: 1. STAIRS SHALL BE NOT LESS THAN 36" IN WIDTH. 2. STAIRWAY RISERS SHALL BE NO GREATER THAN 7 3/4". 3. STAIRWAY TREADS SHALL HAVE A MINIMUM RUN OF 10". 5" MIN 4. THE LENGTH OF RUN AND THE HEIGHT OF RISER SHALL NOT EIGHT VARY MORE THAN 3/8" IN THE RUN OF THE STAIR. 5. OPEN RISERS ARE PERMITTED IF THE OPENINGS IS LESS THAN 4" 6. TREAD NOSING SHALL BE NOT LESS THAN 3/4" BUT NOT MORE THAN 1-1/4" ON STAIRWAYS WITH SOLID RISERS. 7. COMPOSITE MATERIALS MAY REQUIRE ADDITIONAL STRINGERS. DECK 34-38" ABOVE NOSINGS P.T. 2x12 STAIR STINGER L LES HAN HANDRAIL d) 12" O.C. GUARD REQ' 6" DIA. DECKING (SEE PLAN FOR SIZE & TYPE) I MORE THAN 30 LANDING SAME P.T. 2x4 KICKER PLATE ❑OPEN RISERS LESS THAN 4" WIDTH OF STAIRS 3' MIN CONCRETE LANDING F❑36" MIN 7 3/4" MAX RISE FINISHED GRADE MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N O � 00 N � Q z < LL V''^^ l Jn 3: M �� re r) Q�-0 M LLO C: zT-1 o N = Ln E -0 0 r' N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:49 AM DRAWN BY: Author SCALE: 1/2" = 1'-0" PARCEL NO: PARCEL LEGAL LEGAL ypGAN OF W ASHN� N n Z OF 'AFC/STEREO \� FSS/ONALE2/12/2024 DETAILS TYPICAL STAIR SECTION GUARDRAIL STAIR DETAIL 1 /2" = 1'-0" 1 /2" = 1'-0" A104.1 ALTERNATE VIEW ALTERNATE VIEW GENERAL STRUCTURAL NOTES A. GENERAL REQUIREMENTS THE CONTRACT STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT THE DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS SHOWN ARE FOR CONTRACTOR'S CONVENIENC. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES AND SHALL COORDINATE ALL DETAILS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, TYPICALDESIGNS, AND GENERAL STRUCTURAL NOTES, NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. TYPICAL DETAILS AND NOTES NOT NECESSARILY INDICATED AT A SPECIFIC LOCATION ON PLANS OR DETAILS SHALL APPLY NONE -THE -LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTIONS OR MAY OMIT INFORMATION FOR CLARITY OF OTHER ITEMS SHOWN. B. BASIS OF DESIGN BUILDING CODE:2018 EDITION OF THE INTERNATIONAL BUILDING CODE. DEAD LOAD: 10PSF ROOF LIVE LOAD: 20PSF FLOOR LIVE LOAD: 40PSF BALCONY & DECK LIVE LOAD: 60PSF ROOF SNOW LOAD: 25PSF C. FOUNDATIONS ALLOWABLE SOIL BEARING PRESSURE = 1,500 PSF BOTTOMS OF ALL FOOTINGS SHALL BE LOCATED A MINIMUM OF 12" BELOW GRADE, UNO. MATERIALS D. CONCRETE CONCRETE FOR THIS PROJECT CONSISTS OF FOUNDATIONS FOR THE STRUCTURE. ALL POURED IN PLACE SHALL HAVE ULTIMATE COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS (DESIGN BASED ON 2500PSI, NO SPECIAL INSPECTION IS REQUIRED). CONCRETE FORM TOLERANCES SHALL BE WITHIN THE SET STANDARDS OF THE AMERICAN CONCRETE INSTITUTE. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND INSPECTED BY THE LOCAL BUILDING DEPARTMENT PRIOR TO THE POURING OF ANY CONCRETE. NO PIPES OR DUCTS SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR LOCATION. ALL CONDUITS IN CONCRETE WALLS TO BE WIRED TO THE WALL REINFORCING. WHEN CONCRETE IS PLACED AGAINST PREVIOUSLY HARDENED CONCRETE, THE INTERFACE FOR SHEAR TRANSFER SHALL BE CLEAN AND FREE OF LAITANCE. E. REINFORCING STEEL ALL REINFORCING BARS, EXCEPT STIRRUPS, SHALL CONFORM TO ASTM A615 GRADE60 (UNO) NO.2 AND NO. 3 TIES AND STIRRUPS SHALL CONFORM TO ASTM A615 GRADE 40. ALL DETAILING FABRICATION AND ERECTION OF REINFORCING STEEL SHALL CONFORM TO THE ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES ACI315. REINFORCING SHALL HAVE MINIMUM CONCRETE COVER AS FOLLOWS: UNFORMED SURFACES EXPOSED TO EARTH 3" FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER 2" ALL SLAB REINFORCEMENT SHOULD BE SUPPORTED TO ENSURE PLACEMENT NEAR THE VERTICAL MIDPOINT OF THE CONCRETE, UNLESS NOTED OTHERWISE ON THE DETAILS. "HOOKING" IS NOT CONSIDERED AN ACCEPTABLE METHOD OF POSITIONING THE STEEL. F. STRUCTURAL LUMBER SOLID SAWN LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE DRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU )WCLIB). ALL SOLID SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED GRADING AGENCY. SOLID SAWN LUMBER SHALL HAVE THE FOLLOWING MINUMIM GRADES. USE: MATERIAL: 2X4 & 2X6 STUDS <=10' LONG HEM FIR STUD OR BETTER ALL OTHER 2X HEM FIR NO. 2 OR BETTER 4X BEAMS AND POSTS HEM FIR NO. 2 OR BETTER 6X BEAMS AND POSTS HEM FIR NO. 1 OR BETTER ALL STRUCTURAL FRAMING AND CONNECTIONS SHALL BE PER CHAPTER 23 OF THE BUILDING CODE. SPECIFIED CONNECTION HARDWARE BY THE SIMPSON STRONG -TIE DESIGNATION. ACTUAL CONNECTION HARDWARE SHALL BE SIMPSON STRONG -TIE, USP STRUCTURAL CONNECTORS OR AN ICC APPROVED EQUAL, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. GLUE -LAMINATED BEAMS (GLB) SHALL BE DOUGLAS FIR, COMBINATION 24F-V4 SIMPLE SPAN BEA,S AND 24F-V8 AT CANTILEVERED OR CONTINUOUS BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: Fb=2400 PSI, Fv=265 PSI, Fc (PERPENDICULAR)=650 PSI, E=1800000 PSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING SHALL BE PER THE LATEST AITC AND WCLA STANDARDS. ALL BEAMS SHALL BEAR THE GRADE STAMP AND AITC STAMP AND CERTIFICATE. PLYWOOD FOR FLOORS SHALL BE AMERICAN PLYWOOD ASSOCIATE (APA) PERFORMANCE RATED SHEATHING CONFORMIN TO STANDARD PS 1-09. LAY PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. ALL NAILING SHALL BE WITH COMMON NAILS AND SOLID 2X BLOCKING SHALL BE PLACED AT ALL RIDGES AND VALLEYS. ALL ROOF AND FLOOR SHEATHING SHALL BE NAILED WITH BOUNDARY NAILING ALONG THE ENTIRE LENGTH OF SUPPORTING MEMBERS USED AS "DRAG" MEMBERS. A DRAG MEMBER IS DEFINED AS A TRUSS OR BEAM DESIGNED TO TRANSMIT A LATERAL FORCE AND/OR A DIAPHRAGM CHORD FORCE AS INDICATED ON THE FRAMING PLANS. PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF PRESSURE TREATED LUMBER. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72 INCHES ON CENTER UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FROM HOLDONWS) SHALL BE EMBEDDED 7 INCHES INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS A PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE DRIVEN SHOT PINS ACCORDING TO ALTERNATE OUTLINED HEREIN UNLESS NOTED OTHERWISE ON PLANS. ALL BOLTS IN WOOD SHALL CONFORM TO ASTM A307 AND SHALL BE INSTALLED IN HOLES BORED WITH A BIT 1/16 INCH LARGER THAN THE DIAMETER OF THE BOLT BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. DAMAGE THREADS AFTER INSTALLATION TO PREVEN LOOSENING. ALL NAILS SHALL BE COMMON WIRE NAILS. UNO, WITH THE FOLLOWING CHARACTERS: 6D: 0.113" DIAMETER X 2" LONG 8D: 0.131" DIAMETER X 2" LONG 1OD: 0.148" DIAMETER X 3" LONG 12D: 0.148" DIAMETER X 3 1/4" LONG 16D: 0.162" DIAMETER X 3 1/2" LONG INTERIOR NON -BEARING WALLS <=14' HIGH SHALL BE 2X4 STUDS AT 16" O.C. DO NOT NOTCH OR DTILLJOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. DOUBLE UP FLOOR JOISTS UNDER PARALLEL PARTITIONS. PROVIDE TRANSVERSE BLOCKING BETWEEN TRUSSES UNDER ALL PARALLEL PARTITIONS. PROVIDE 2" NOMINAL SOLID NAILERS UNDER ALL WALLS DESIGNATED ON THE FRAMING PLANS AS SHEAR WALLS. PROVIDE2" NOMINAL SOLID BLOCKING AT SUPPORTS OF ALL JOISTS AND TRUSSES. G. QUALITY ASSURANCE REQUIREMENTS SPECIAL INSPECTION PER IBC SECTION 1705 SHALL BE PROVIDED FOR THE FOLLOWING ITEMS: REINFORCING BAR OR BOLTS ANCHORED BY EPDXIES OR GROUTS ANCHOR BOLTS MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N MO W N � M Q z Q ''^^ Vl J 3: M I-1 � a— 4-.J M LL_O C: z� O N = Ln E -0 p r' N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:51 AM DRAWN BY: Author SCALE: PARCEL NO: PARCEL LEGAL LEGAL �pGAN hP��pF WASy�� P 57648 GISTE0.E0 \� FSS/ONALE2/12/2024 RENDERINGS & GENERAL NOTES A105 1'-0" 0 F- SOUTH ELEVATION 1 /411 = 1'-011 21'-0" �0 L 13'-0" 10'-0" 3'-0" 77 s:---a -E E --d —d —1 � —5 ���E S :--::d E E � E M o - _- EAST ELEVATION WEST ELEVATION 1 /4" = 1'-0" MASTERDECKS LLC MASTELS36BZ EXP 1/17/2025 O N O � 00 1■■1 � M Q z Q LL. M J 3: M F--1a- � Q�-0 MLL-O C: zT---1 O N = Ln E -0 O ,-I N LU Revision Schedule Revision Revision Number Date PROJECT CONTACT: RYAN QUINN 206.518.2786 DATE: 2/12/2024 9:21:53 AM DRAWN BY: Author SCALE: 1/4" = 1'-0" PARCEL NO: PARCEL LEGAL LEGAL BUILDING ELEVATIONS A106 1 /411 = 1 '-0"