REVIEWED BLD2022-1135+Krazan Report+8.22.2022_6.47.07_PM+3066149GEOTECHNICAL ENGINEERING . ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
June 17, 2022
Mr. Frank Song (E-Mail)
SIX STAR LLLP
19411 56t' Avenue W, Suite 317
Lynnwood, WA 98036
RE: CONSTRUCTION TESTING AND INSPECTION
Song SIR
17727 76' Avenue W.
Edmonds, Washington
Dear Mr. Song,
RECEIVED
Aug 30 2022
DEVELOPMENT SERVICES
DEPARTMENT
BLD2022-1128
KA No. 096-22310
In accordance with your request and authorization, our firm performed construction testing and inspection
for the above -referenced project. The sampling and testing was performed by our inspectors and reports
are included.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our
office.
JSMAkj
INC.
SHOP DRAWING I SUBMITTAL REVIEW
XAPPROVED APPROVED WITH CHANGES NOTED
REVISE AND RESUBWT REJECTED.
SUBMITTAbIIIIIIIIIIIIIIIIEVARMFMCESIGN CONFORMITY AND
GENERAL CONFORMANCETO CONTRACT DOCUMENTS ONLY.
CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND
CORRELATING DIMENSIONSAT JOB SITES FOR TOLERANCES.
CLEARANCE, QUANTITIES. FABRICATION PROCESSESAND
TECHNIQUES OF CONSTRUCTION. COORDINATION OF HIS OR HER
WORK WITH OTHER TRADESAND FULL COMPLIANCE WITH
CONTRACT DOCUMENTS.
CaT, 6-21-2022
Eui S Kim, PE
4303 198te Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837
With Ojjiees Serving the Western United States
0%22310 DFR
��iQz++� r�]Y1 Page I of 3
Ilm.Assoc hat as, Inc Field
Geotechnieal Engineering . Environmental Engineering Report NO.: 0962231ODFR6152022JM
Canstmction Tesling and Inspection
Inspector Josh N irabella conducted a general special inspection of concrete basement walls at the
property. Compressive strength of the walls was estimated using a Schmidt hammer and the condition and
location of reinforcing steel was determined using a Hilti Ferroscanner. Plans below indicate locations at
which the Schmidt hammer was used with teal Xs and locations scanned for reinforcing steel with red
lines. See below for more details on each inspection.
Compressive Strength
At three separate locations on the walls, 12 tests were conducted in a 3x4, one in' grid. Excluding
outliers, the 12 tests were averaged to obtain an estimated strength. Then the three averages were again
averaged to obtain an estimate for all walls.
Location 1 estimate:7200psi
Location 2 estimate: 4100 psi
Location 3 estimate:4500 psi
Averaged estimate: 5300 psi
Device used:
Schmidt Hammer
B-133
N2-3
ADTEK ID#: 8446
Calibrated Oct, 2020
Reinforcing Steel
The walls of interest (as marked on the plans) were scanned in their entirety (where existing structures
and features allowed) and the determined locations of rebar were marked directly on the wall in red.
Rebar both vertical and horizontal was estimated to be at least #4 bar at all locations. Vertical rebar
appeared to be spaced at two -foot intervals. Horizontal rebar in the bedroom appeared to be also spaced at
two -foot intervals, but switched to one -foot intervals in the bed room, media room, hallway, and
bedroom. All rebar appeared to be between 3 and 5 inches under the surface.
The footings below the wall could not be scanned due to their size, but at one location rebar is visible
sticking out and it is suspected that there is similar rebar throughout the footing.
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
m.wrmm a� i•m�.�� �.�.amrm.mm;..®.mm.am<nu�.onmwowe.�mwwm+d ��mw w.w�nmvwres�mm.mm.mv.�s.monu. m,�
mnmwu m��mummwwamamm�auomm®eae.aww., �y,yp „ynu,
�mwwiwu�riw..uaroa�im rn....eurt.timnue®v��amMmee,®ea.rmm,mumwvbmbwm.wm�mmn�®.,me�m�mWmtem�m�wonw®vw+mmwowavrq
Page 2 of 3
aM
&Associates Inc Field
ueotechniwl Engineering . Environmental Engineering Report NO.: 09622310DFR61520223M
Construction Testing and Inspecgon
H
T
Example of wall! markings in the bedroom area
Device used:
HILTI PS 300-w 01
Model: PS300-w
IC. 5228A-PS300R7
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
Page 3 of 3
&Associataa Inc Field
ueotemnical Engineering . Environmental Engineering ReportN0.:09622310DFR6152022FM
Construction Testing and Inspection
BASEMENT FLOOR PLAN
Plans with inspected areas marked
4e }
To the best of my Imowledie, the above WAS performed in accordance with the approved plans, specifications and