Loading...
REVIEWED BLD2022-1135+Krazan Report+8.22.2022_6.47.07_PM+3066149GEOTECHNICAL ENGINEERING . ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION June 17, 2022 Mr. Frank Song (E-Mail) SIX STAR LLLP 19411 56t' Avenue W, Suite 317 Lynnwood, WA 98036 RE: CONSTRUCTION TESTING AND INSPECTION Song SIR 17727 76' Avenue W. Edmonds, Washington Dear Mr. Song, RECEIVED Aug 30 2022 DEVELOPMENT SERVICES DEPARTMENT BLD2022-1128 KA No. 096-22310 In accordance with your request and authorization, our firm performed construction testing and inspection for the above -referenced project. The sampling and testing was performed by our inspectors and reports are included. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office. JSMAkj INC. SHOP DRAWING I SUBMITTAL REVIEW XAPPROVED APPROVED WITH CHANGES NOTED REVISE AND RESUBWT REJECTED. SUBMITTAbIIIIIIIIIIIIIIIIEVARMFMCESIGN CONFORMITY AND GENERAL CONFORMANCETO CONTRACT DOCUMENTS ONLY. CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONSAT JOB SITES FOR TOLERANCES. CLEARANCE, QUANTITIES. FABRICATION PROCESSESAND TECHNIQUES OF CONSTRUCTION. COORDINATION OF HIS OR HER WORK WITH OTHER TRADESAND FULL COMPLIANCE WITH CONTRACT DOCUMENTS. CaT, 6-21-2022 Eui S Kim, PE 4303 198te Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837 With Ojjiees Serving the Western United States 0%22310 DFR ��iQz++� r�]Y1 Page I of 3 Ilm.Assoc hat as, Inc Field Geotechnieal Engineering . Environmental Engineering Report NO.: 0962231ODFR6152022JM Canstmction Tesling and Inspection Inspector Josh N irabella conducted a general special inspection of concrete basement walls at the property. Compressive strength of the walls was estimated using a Schmidt hammer and the condition and location of reinforcing steel was determined using a Hilti Ferroscanner. Plans below indicate locations at which the Schmidt hammer was used with teal Xs and locations scanned for reinforcing steel with red lines. See below for more details on each inspection. Compressive Strength At three separate locations on the walls, 12 tests were conducted in a 3x4, one in' grid. Excluding outliers, the 12 tests were averaged to obtain an estimated strength. Then the three averages were again averaged to obtain an estimate for all walls. Location 1 estimate:7200psi Location 2 estimate: 4100 psi Location 3 estimate:4500 psi Averaged estimate: 5300 psi Device used: Schmidt Hammer B-133 N2-3 ADTEK ID#: 8446 Calibrated Oct, 2020 Reinforcing Steel The walls of interest (as marked on the plans) were scanned in their entirety (where existing structures and features allowed) and the determined locations of rebar were marked directly on the wall in red. Rebar both vertical and horizontal was estimated to be at least #4 bar at all locations. Vertical rebar appeared to be spaced at two -foot intervals. Horizontal rebar in the bedroom appeared to be also spaced at two -foot intervals, but switched to one -foot intervals in the bed room, media room, hallway, and bedroom. All rebar appeared to be between 3 and 5 inches under the surface. The footings below the wall could not be scanned due to their size, but at one location rebar is visible sticking out and it is suspected that there is similar rebar throughout the footing. Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 m.wrmm a� i•m�.�� �.�.amrm.mm;..®.mm.am<nu�.onmwowe.�mwwm+d ��mw w.w�nmvwres�mm.mm.mv.�s.monu. m,� mnmwu m��mummwwamamm�auomm®eae.aww., �y,yp „ynu, �mwwiwu�riw..uaroa�im rn....eurt.timnue®v��amMmee,®ea.rmm,mumwvbmbwm.wm�mmn�®.,me�m�mWmtem�m�wonw®vw+mmwowavrq Page 2 of 3 aM &Associates Inc Field ueotechniwl Engineering . Environmental Engineering Report NO.: 09622310DFR61520223M Construction Testing and Inspecgon H T Example of wall! markings in the bedroom area Device used: HILTI PS 300-w 01 Model: PS300-w IC. 5228A-PS300R7 Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 Page 3 of 3 &Associataa Inc Field ueotemnical Engineering . Environmental Engineering ReportN0.:09622310DFR6152022FM Construction Testing and Inspection BASEMENT FLOOR PLAN Plans with inspected areas marked 4e } To the best of my Imowledie, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements, Offices Serving the Western united States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500