Loading...
REV1 APPROVED BLD BLD2023-0407 Floor Plan Update 2024-01-18Window Schedule Mark Family Width Height Count Comments 10 Fixed 2'-6" 4'-0" 3 U value: 0.24 17 Fixed 2'-0" 3'-0" 1 U value: 0.24 20 Casement with Trim 2'-0" 4'-0" 1 U value: 0.24 25 Casement with Trim 2'-0" 6'-0" 1 U value: 0.24 29 Fixed with Trim 2'-0" 4'-0" 3 U value: 0.24 34 Fixed with Trim 2'-0" 6'-0" 3 U value: 0.24 36 Fixed with Trim 3'-0" 6'-0" 2 U value: 0.24, 38 Casement with Trim 2'-0" 3'-2" 6 U value: 0.24, saftey glazing 39 Fixed with Trim 2'-0" 3'-2" 5 U value: 0.24, saftey glazing 40 Casement with Trim 2'-0" 4'-10" 8 U value: 0.24 42 Casement with Trim 1'-9" 4'-10" 2 U value: 0.24 43 Fixed with Trim 3'-9" 4'-10" 4 U value: 0.24 45 Fixed with Trim 2'-0" 4'-10" 4 U value: 0.24 55 Casement with Trim 2'-0" 4'-10" 5 U value: 0.24 82 Fixed 5'-6" 3'-0" 1 U value: 0.24 86 Casement with Trim 2'-10" 4'-4" 2 U value: 0.24 87 Fixed with Trim 2'-10" 4'-4" 2 U value: 0.24 95 Fixed with Trim 2'-4" 4'-10" 1 U value: 0.24 96 Casement with Trim 2'-4" 4'-10" 3 U value: 0.24 98 Fixed with Trim 4'-0" 6'-0" 1 U value: 0.24 101 Fixed with Trim 1'-6" 5'-0" 1 U value: 0.24 104 Fixed with Trim 5'-8" 2'-0" 1 U value: 0.24 117 Window-skylight-Velux tubular-fle x 0'-0" -0'-1" 7 U value: 0.24 123 Window-skylight-VELUX_FCM-cu rb mounted -fixed 2'-3 1/8" 4'-3 1/8" 15 count includes (4) existing skylights 131 Foundation crawl space Vent 4 U value: 0.24 133 Awning with Trim 3'-6" 1'-2" 1 U value: 0.24 134 Awning with Trim 3'-0" 1'-2" 1 U value: 0.24 135 Casement with Trim 4'-0" 5'-0" 2 Exist Fixed <varies> <varies> 3 Grand total: 93 Door Schedule Dr No. Type Door Comments Width Height Thickness Mtl 3 8 2'-8" 6'-8" 0'-2" 4 8 2'-8" 6'-8" 0'-2" 5 8 2'-8" 6'-VQQ" 0'-2" 11 6 3'-0" 6'-8" 0'-2" 12 11 5'-8" 6'-8" 0'-2" 25 8 2'-8" 6'-8" 0'-2" 35 7 2'-10" 6'-8" 0'-2" 38 25 6-0" 6'-8" 0'-1 1/2" 48 7 2'-10" 6'-8" 0'-2" 49 7 2'-10" 6'-8" 0'-2" 50 7 2'-10" 6'-8" 0'-2" 51 26 4'-0" 6'-8" 0'-1 1/2" 52 26 4'-0" 6'-8" 0'-11/2" 106A 6 3'-0" 6'-8" 0'-2" 20 min rated, with spring closure 107 1 5 2'-6" 6'-8" 0'-2" 109 5 2'-6" 6'-8" 0'-2" 110 7 2'-10" 6'-8" 0'-2" 110A 26 4'-0" 6'-8" OVA 1/2" 110B 26 4'-0" 6'-8" 0'-1 1/2" 111 5 2'-6" 6'-8" 0'-2" 112 46 3'-0" 6'-8" 117 D 44 2'-0" 6'-8" 0'-2" 117E 68 5'-8" 6'-8" 0'-2" 117 G 65 5'-0" 6'-8" 0'-1 3/4" 1171 6 3'-0" 6'-8" 0'-2" 117J 71 7'-0" 6'-8" 0'-1 1/2" 117 M 74 6'-0" 7'-0" 0'-2" 117 N 5 2'-6" 6'-8" 0'-2" 117 Q 60 4'-0" 6'-8" 0'-2" 117 R 60 4'-0" 6'-8" 0'-2" 117S 60 4'-0" 6'-8" 0'-2" 117T 60 4'-0" 6'-8" 0'-2" 118 14 8'-0" 6'-6" 118 64 2'-6" 6'-8" 119 14 8'-0" 6'-6" 119 5 2'-6" 6'-8" 0'-2" 120 6 3'-0" 6'-8" 0'-2" 120A 65 5'-0" 6'-8" OVA 3/4" 121 8 2'-8" 6'-8" 0'-2" 122 14 8'-0" 6'-6" 123 8 2'-8" 6'-8" 0'-2" 124 5 2'-6" 6'-8" 0'-2" 127 7 2'-10" 6'-8" 0'-2" 128 46 3'-0" 6'-8" Exist 41 5-0" 7'-0" OVA 3/4" 10 9 8 A201 7 6 4 5 4 ,� 3 2 `� 1 A201 / \ 10'- 1 1/4" 18' - 3 1/4" 15' - 9 1/2" // 23' - 11 3/4" \ / y 14'-15/8" 34'-03/4" -- - - - - - - - ----------00 2 -4- -- --- -- I---, � C) xis I \I " I. — 1 — — �0 — — 0 —� — — 13'-7" 7t_ 7'-013'-53/4" rn o 71 + B Relocated existing front door Zo / 3' - 6" 3' - 6" / — — " — 2D 11'- 1 1/4" EI E\\ V_2" '-2" 3'-23/4" 98 v 122 \\ x Existing wood stud walls et on top of existing \ _� J \ w L J foundation to remain. Exi ting upper masonry \ F \ Ek_0� wall(s) set above the soli er course that \ \ 101 I Exist extend to the top of the c imney, to be I Exist demolished (typical for front bay window). I — —11 u,I I, � dU Exist Exist uU _ ' \ �Q �Q 4'- 10 9/16" I 1'-0" 1'-0" / ----- E II\ �- Ij - j --II_ Exist y U) w \ Dining Room / \ \ �\ 102 �/ \ Garage \ 108 \ j w 119�� I N I � � I Living X I / �� 1104 I + N w (3) equal risers with 11" = c�1 tr ads for revised garage access \\ / I _ r door jQr= Modify existing attic access to - - _ E I gas 00 accomiate new folding access see: _ ------ 33'-41/2" ��_-----_I\ 13' - 0". 1 7' - 0" A202 / I I I I I X j E E \ I qP E E($ E \ 1 _ - _ Exhaust vent linked to 100 cfm cent Izerl ed \ 10 1/2" - -I- 1 ' - 11 1/ " �' fan with 4" dia ducting , set in ceiling over E \ Hall 118 \ Bedrm 2, rm #110. O Terminate exhaust fan thru roof �� 103 \ N 4' - " veri Existing gas furnace to remain and up�rade as Approximate location a existing elec meter, to be relocated to 40 abo similar see: 5 9 _ ith mfg. necessary to supply new heated additi n east wall C 9 GFI S C O2 Family Room - - A202 ti Central Relocated gas water heater/boiler, to u ilzed Approximate location of - - - - - - - - - - - - - � 105 _ - - - - - \ — ■ N - V — existing vent path thru garage roof x co I _ — — vacum existing elec panel to remain 40 I I -°' U HSS 6x6x1/8" x 42" high weld to PL 1/4"x U a)3 o O E �/ �V M ` 6"x6" set with (4) 5/8"x 3" expansion bolts _ — — o — � — into conc slab o �' Exist Exist 24"x24" access panel to centralized bath rm iv I N / �y 3 X L N Exist exhaust fan, with min. 100 cfm, servicing 1/2 4'- 4 1/2" 5' - 6 1/ " a, 3'- 9" 2' - 8" 3' - 11" 20'- 0 1/4" c o 0 C,I X bath #107, and laundry room #112 0 _ 0 New location of elec meter, and data W 1 — — — Hem, 6" sub panel I _0) 0)1 - � - Q 3 W W ,_-_� -- � /J M SC 2 106 1-- - — / , — \ / Nooks _ - - ,� — / o Bench7, GFI o 114 ] 24"x24" access panel to - 3' - 0" X I / Office N Sun tube _ centralized room exhaust fan, ~ ,k W / 111 It - - w/ min 100 cfm servicing bath M Expanded dec 6 A801 8 / / /L "' '_ 13 � -!� #109, & master bath #119 95 o Interior elev's / I / C14 X Bath terminate thru roof a ove �9r island- - J 109 Bedroom 2 se7�9 3'-25/16"+/- 6'- "+/- exi Ing ----- 9 - 2 2 2 V� $1 $1 112 110 eck to rem in �� - , C� A801 110 I / o cco 13 CD LO � I III U (3) \ 3 A801 z I \ 2 13 IDS Type A Door Types 1/4" = 1'-0" 0 3/8" N ' �}. -I' I A202 96 N o N , Equal \ 5' - 0" . �' Equal// 2' - 3 1 1 - 10 _ / N 2'-7" 4'-8" 3'-3" 16'-03/4" Laundry d � � \ Outlet set below / / - - - 112 5 w� �1 '_�'\ counter, typical I — _\1_ — O V � c,, 3 M j Exist X \ _ - 3 - \ -� _ � Kitchen 115 � \I 1 �lo I — j —LIn 1 I — \ i Study I �s I' \ 120 as I O I L_ — _J L_ — J N 1 _ _/ /1 o Bedroom 1 DW °' -7- � \ - 1 - \ -5,-1„ 5,-1„ �\ - 8„ ---- 10, 2�� --- - -- - - - - - - _1'- 7 1 /2" 4' - 3 1/2"-- — — — 0 Existing steps/railing from deck to remain t- New -------------------------------36" high wood railing to match existing egress casemt 24"x42" to remain Edge of existing roof overhang Ype B -.r ` 1 10' - 1 1/4" Main (Floor New Construction 1 /4" - 1'-0" — 18' - 3 1/4" I I 2'- 1 1/2" Align extension of ` �l wall with exiting wall N I I I /.100 1*4 oilet 2 124 I -I loset 3'- 8" 6' - 10 1 /2" 6' - 10" 5' - 7 1/4" \\ / iD cc \ A801 \ \ _ / aster Bath 14 _ 119 Q _ / M N \ - I N Q➢ C Bath / o■ 121 00 1 4'- 2" 0 I I I � U 7'-o°I I S Exhaust vent powerd by 100 cfm \ \ centerlized fan in ceiling over Bedrm 2, -rm #110, see note for fan in rm #105 \ 2x4 partition to provide for pocket door #118 overun Light/exhaust fan Master Bedroom 120 Remove siding from exisitng wall add new layer of 1/2" GWB perserve existing shear plywd I 60 I Sittinq RooLO m 1 45 , o 1 123 o ' I I co 4'-101/2" 3'-1" 3'-1" 4'-9" E v i CM w w 96 --- Exit Exist 40 43 40 3 14 - 0 ti g exteri r portion of 16 - 3 3/4 - - - to rem a n unchan New addition 15' - 9 1/2" 23' - 11 3/4" CV N 0 Ch 16 A202 R1 Relocated hose bib - Relocated gas ME ,411�9 A202 8 A202 Align new gable end roof to align with overhana of existina hiD roof �t,►1it„it. Z r C:) 0 Lit] L0 � t oo w r` r I Z � Z L0 ­_ N L s1' � ° I 14, 0 o N LL Z C)z 00 Q Z 0 4_0 w C) 0 Ir a- w L0 CDIr o w ^ m o Z N O z (� 00o Q ^,0 W I rn Q w U o 1 � w co 0 w W W C � O = E 0 � Lu W Q —� a- o I I__ W U w U Q 0 < Q - ^`ILL 1_ � � = L4 Ci d 0CD Cn O L m O 0 W isteried Y D. SHAPIRO Washincitilln REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Erica C4w,ter BUILDING OFFICIAL Jan 24 2024 APPROVED DATE M N N N Z6�� O N � LoL� 000 m � Q REVISION Jan 19 2024 W CITY OF EDMONDS I- DEVELOPMENT SERVICES 0 DEPARTMENT •cn c Q BLD2023-0407 �L U p •o O E ° 06 o 0 U O 2 I_ N co J d CO O Z a M 'SHEET TITLE (f) Main Floor New Construction, Door and W Window Schedule, Door Types 0) SCALE: CHECKED BY: U 1/4" = 1'-0" AS DATE: PROJ. No: 04/24/23 12659-00 (3) SHEET No: U_ , Al 04