REV1 APPROVED BLD BLD2023-0407 Floor Plan Update 2024-01-18Window Schedule
Mark Family Width Height Count Comments
10
Fixed
2'-6"
4'-0"
3
U value: 0.24
17
Fixed
2'-0"
3'-0"
1
U value: 0.24
20
Casement with Trim
2'-0"
4'-0"
1
U value: 0.24
25
Casement with Trim
2'-0"
6'-0"
1
U value: 0.24
29
Fixed with Trim
2'-0"
4'-0"
3
U value: 0.24
34
Fixed with Trim
2'-0"
6'-0"
3
U value: 0.24
36
Fixed with Trim
3'-0"
6'-0"
2
U value: 0.24,
38
Casement with Trim
2'-0"
3'-2"
6
U value: 0.24, saftey glazing
39
Fixed with Trim
2'-0"
3'-2"
5
U value: 0.24, saftey glazing
40
Casement with Trim
2'-0"
4'-10"
8
U value: 0.24
42
Casement with Trim
1'-9"
4'-10"
2
U value: 0.24
43
Fixed with Trim
3'-9"
4'-10"
4
U value: 0.24
45
Fixed with Trim
2'-0"
4'-10"
4
U value: 0.24
55
Casement with Trim
2'-0"
4'-10"
5
U value: 0.24
82
Fixed
5'-6"
3'-0"
1
U value: 0.24
86
Casement with Trim
2'-10"
4'-4"
2
U value: 0.24
87
Fixed with Trim
2'-10"
4'-4"
2
U value: 0.24
95
Fixed with Trim
2'-4"
4'-10"
1
U value: 0.24
96
Casement with Trim
2'-4"
4'-10"
3
U value: 0.24
98
Fixed with Trim
4'-0"
6'-0"
1
U value: 0.24
101
Fixed with Trim
1'-6"
5'-0"
1
U value: 0.24
104
Fixed with Trim
5'-8"
2'-0"
1
U value: 0.24
117
Window-skylight-Velux tubular-fle
x
0'-0"
-0'-1"
7
U value: 0.24
123
Window-skylight-VELUX_FCM-cu
rb mounted -fixed
2'-3 1/8"
4'-3 1/8"
15
count includes (4) existing
skylights
131
Foundation crawl space Vent
4
U value: 0.24
133
Awning with Trim
3'-6"
1'-2"
1
U value: 0.24
134
Awning with Trim
3'-0"
1'-2"
1
U value: 0.24
135
Casement with Trim
4'-0"
5'-0"
2
Exist
Fixed
<varies>
<varies>
3
Grand total: 93
Door Schedule
Dr
No.
Type
Door
Comments
Width
Height
Thickness
Mtl
3
8
2'-8"
6'-8"
0'-2"
4
8
2'-8"
6'-8"
0'-2"
5
8
2'-8"
6'-VQQ"
0'-2"
11
6
3'-0"
6'-8"
0'-2"
12
11
5'-8"
6'-8"
0'-2"
25
8
2'-8"
6'-8"
0'-2"
35
7
2'-10"
6'-8"
0'-2"
38
25
6-0"
6'-8"
0'-1 1/2"
48
7
2'-10"
6'-8"
0'-2"
49
7
2'-10"
6'-8"
0'-2"
50
7
2'-10"
6'-8"
0'-2"
51
26
4'-0"
6'-8"
0'-1 1/2"
52
26
4'-0"
6'-8"
0'-11/2"
106A
6
3'-0"
6'-8"
0'-2"
20 min rated, with spring
closure
107
1 5
2'-6"
6'-8"
0'-2"
109
5
2'-6"
6'-8"
0'-2"
110
7
2'-10"
6'-8"
0'-2"
110A
26
4'-0"
6'-8"
OVA 1/2"
110B
26
4'-0"
6'-8"
0'-1 1/2"
111
5
2'-6"
6'-8"
0'-2"
112
46
3'-0"
6'-8"
117 D
44
2'-0"
6'-8"
0'-2"
117E
68
5'-8"
6'-8"
0'-2"
117
G
65
5'-0"
6'-8"
0'-1 3/4"
1171
6
3'-0"
6'-8"
0'-2"
117J
71
7'-0"
6'-8"
0'-1 1/2"
117
M
74
6'-0"
7'-0"
0'-2"
117 N
5
2'-6"
6'-8"
0'-2"
117
Q
60
4'-0"
6'-8"
0'-2"
117 R
60
4'-0"
6'-8"
0'-2"
117S
60
4'-0"
6'-8"
0'-2"
117T
60
4'-0"
6'-8"
0'-2"
118
14
8'-0"
6'-6"
118
64
2'-6"
6'-8"
119
14
8'-0"
6'-6"
119
5
2'-6"
6'-8"
0'-2"
120
6
3'-0"
6'-8"
0'-2"
120A
65
5'-0"
6'-8"
OVA 3/4"
121
8
2'-8"
6'-8"
0'-2"
122
14
8'-0"
6'-6"
123
8
2'-8"
6'-8"
0'-2"
124
5
2'-6"
6'-8"
0'-2"
127
7
2'-10"
6'-8"
0'-2"
128
46
3'-0"
6'-8"
Exist
41
5-0"
7'-0"
OVA 3/4"
10 9 8 A201 7 6 4 5 4 ,� 3 2 `� 1
A201 / \
10'- 1 1/4" 18' - 3 1/4" 15' - 9 1/2" // 23' - 11 3/4" \
/ y
14'-15/8" 34'-03/4" -- - - - - - - - ----------00
2 -4- -- --- -- I---, � C) xis I \I
" I.
— 1 — — �0 — — 0 —� — —
13'-7" 7t_ 7'-013'-53/4"
rn o 71
+ B
Relocated existing front door Zo / 3' - 6" 3' - 6"
/ — — " — 2D 11'- 1 1/4" EI E\\
V_2" '-2" 3'-23/4"
98 v
122 \\
x Existing wood stud walls et on top of existing \
_� J \ w L J foundation to remain. Exi ting upper masonry \
F \ Ek_0� wall(s) set above the soli er course that \
\ 101 I Exist extend to the top of the c imney, to be I
Exist demolished (typical for front bay window). I
— —11
u,I I, �
dU Exist Exist uU _ ' \ �Q �Q 4'- 10 9/16" I
1'-0" 1'-0" /
----- E II\ �- Ij - j --II_ Exist y
U)
w
\ Dining Room / \ \
�\ 102 �/ \ Garage
\ 108 \
j w
119��
I N I � � I Living
X I / �� 1104 I + N w (3) equal risers with 11"
= c�1 tr ads for revised garage access \\
/ I _ r door
jQr= Modify existing attic access to
- - _ E I gas 00 accomiate new folding access see:
_
------ 33'-41/2" ��_-----_I\
13' - 0". 1 7' - 0" A202 /
I I I I I X
j E E \ I qP
E E($ E \ 1 _ - _ Exhaust vent linked to 100 cfm cent Izerl ed
\ 10 1/2" - -I- 1 ' - 11 1/ " �' fan with 4" dia ducting , set in ceiling over E
\ Hall 118
\ Bedrm 2, rm #110.
O Terminate exhaust fan thru roof �� 103 \ N 4' - " veri Existing gas furnace to remain and up�rade as Approximate location a existing
elec meter, to be relocated to
40 abo similar see: 5 9 _ ith mfg. necessary to supply new heated additi n east wall
C 9 GFI S C O2
Family Room - - A202 ti Central Relocated gas water heater/boiler, to u ilzed Approximate location of
- - - - - - - - - - - - - � 105 _ - - - - - \ — ■ N - V — existing vent path thru garage roof
x co I _ — — vacum existing elec panel to remain
40 I I -°' U HSS 6x6x1/8" x 42" high weld to PL 1/4"x
U a)3 o O E �/ �V M ` 6"x6" set with (4) 5/8"x 3" expansion bolts
_ — — o — � — into conc slab
o �' Exist Exist 24"x24" access panel to centralized bath rm iv I N / �y
3 X L N Exist exhaust fan, with min. 100 cfm, servicing 1/2 4'- 4 1/2" 5' - 6 1/ " a, 3'- 9" 2' - 8" 3' - 11" 20'- 0 1/4"
c o 0 C,I X bath #107, and laundry room #112 0 _ 0 New location of elec meter, and data
W 1 — — — Hem, 6" sub panel I
_0) 0)1 - � -
Q 3 W W ,_-_� -- � /J M SC 2 106
1--
- — / , — \
/ Nooks _ - - ,� — / o Bench7,
GFI o
114 ]
24"x24" access panel to -
3' - 0" X I / Office N Sun tube _ centralized room exhaust fan, ~
,k W / 111 It - - w/ min 100 cfm servicing bath M
Expanded dec 6 A801 8 / / /L "' '_ 13 � -!� #109, & master bath #119 95
o Interior elev's / I / C14
X Bath terminate thru roof a ove
�9r island- - J 109 Bedroom 2 se7�9
3'-25/16"+/- 6'- "+/- exi Ing ----- 9 -
2 2 2 V� $1 $1 112 110
eck to rem in �� - , C� A801 110 I
/ o
cco 13
CD
LO
� I
III
U
(3) \ 3 A801
z I \
2
13
IDS
Type A
Door Types
1/4" = 1'-0"
0 3/8"
N ' �}. -I' I A202 96 N o
N , Equal \ 5' - 0" . �' Equal// 2' - 3 1 1 - 10 _
/ N 2'-7" 4'-8" 3'-3" 16'-03/4"
Laundry d � � \ Outlet set below / / - - - 112 5 w� �1 '_�'\
counter, typical I — _\1_ — O V � c,, 3 M
j Exist
X
\
_
-
3 -
\
-�
_
� Kitchen
115
� \I
1
�lo
I
—
j
—LIn
1
I
—
\ i
Study
I
�s
I'
\
120
as I
O
I
L_ —
_J L_
— J
N
1
_
_/
/1
o
Bedroom 1
DW
°'
-7- �
\ - 1
- \ -5,-1„ 5,-1„ �\ -
8„ ---- 10, 2�� --- - -- - - - - - -
_1'- 7 1 /2" 4' - 3 1/2"-- — — — 0
Existing steps/railing from deck to remain t-
New -------------------------------36" high wood railing
to match existing
egress casemt 24"x42" to
remain
Edge of existing roof overhang
Ype B -.r `
1 10' - 1 1/4"
Main (Floor New Construction
1 /4" - 1'-0" —
18' - 3 1/4"
I I
2'- 1 1/2"
Align extension of `
�l wall with exiting wall
N I I I
/.100 1*4
oilet 2
124
I -I
loset
3'- 8" 6' - 10 1 /2" 6' - 10" 5' - 7 1/4"
\\ / iD cc \ A801 \
\ _ / aster Bath 14
_ 119
Q _ / M
N \ - I
N Q➢
C Bath / o■
121
00
1 4'- 2"
0
I I
I
� U 7'-o°I
I S
Exhaust vent powerd by 100 cfm
\ \ centerlized fan in ceiling over Bedrm 2,
-rm #110, see note for fan in rm #105
\ 2x4 partition to provide for pocket door
#118 overun
Light/exhaust fan
Master Bedroom
120
Remove siding from exisitng wall add
new layer of 1/2" GWB perserve
existing shear plywd I 60
I
Sittinq RooLO
m 1 45
, o 1 123
o ' I I
co
4'-101/2" 3'-1" 3'-1" 4'-9" E
v i CM
w
w 96
---
Exit Exist 40 43 40
3 14 - 0 ti g exteri r portion of 16 - 3 3/4
- - -
to rem a n unchan New addition
15' - 9 1/2" 23' - 11 3/4"
CV
N
0
Ch
16
A202
R1
Relocated hose bib
- Relocated gas ME
,411�9
A202
8
A202
Align new gable end roof to align
with overhana of existina hiD roof
�t,►1it„it. Z
r C:) 0
Lit] L0 �
t oo w
r`
r
I Z � Z
L0 _
N L
s1'
�
°
I
14,
0
o
N
LL
Z
C)z
00
Q
Z
0
4_0
w
C)
0
Ir
a-
w
L0
CDIr
o w
^
m
o Z
N O
z
(�
00o Q
^,0
W
I
rn
Q w
U
o
1
� w
co
0 w
W
W
C �
O =
E 0
�
Lu
W
Q
—�
a-
o
I I__
W
U
w
U
Q
0
<
Q
-
^`ILL
1_
� �
=
L4 Ci
d
0CD
Cn
O
L
m
O 0
W
isteried
Y D. SHAPIRO
Washincitilln
REVISED PLAN APPROVED
CITY OF EDMONDS BUILDING DIVISION
Erica C4w,ter
BUILDING OFFICIAL
Jan 24 2024
APPROVED DATE
M
N N N
Z6��
O N �
LoL�
000
m
�
Q
REVISION
Jan 19 2024
W
CITY OF EDMONDS
I-
DEVELOPMENT SERVICES
0
DEPARTMENT
•cn
c
Q
BLD2023-0407
�L
U
p
•o
O E °
06 o
0 U
O
2
I_
N co
J d CO
O
Z
a M
'SHEET TITLE
(f) Main Floor New Construction, Door and
W Window Schedule, Door Types
0)
SCALE: CHECKED BY:
U 1/4" = 1'-0" AS
DATE: PROJ. No:
04/24/23 12659-00
(3) SHEET No:
U_
, Al 04