Loading...
APPROVED ENG RESUB1 BLD2024-0596+SITE PLAN+7.3.2024_3.21.17_PM+4358609 1PRO1Fr`T INFORMATION Owner and address: Corrigan Family Trust Kevingand Kathleen 909 71" Ave S Edmonds, WA 98020 Parcel 10: 27032500202400 Neighborhood: 1605001 NW1 /4 SEC25 T27N R3E sot Demo existing deck and install new i 5 2nO story, 150 sf composite deck. sj N CODES AND DESIGN LIVE LOADS All methods, materials and workmanship shall conform to the 2018 International Code (IRC) as amended and adopted by the local Building Department Snow load: 25 psf Deck live load: 60 psf _Seismic Criteria: Assumed Soil Site Class D; Seismic Design Category D; Sds = 0.859; I = 1.0 FOUNDATION AND SOIL PRESSURE Presumptive vertical foundation pressure: 1,500 psf. STRUCTURAL REINFORCED CONCRETE All concrete shall meet the requirements of ACI-301, "Specifications For Structural Concrete For Buildings." Place concrete per ACI-304 and conform to ACI-306R for cold weather placement and ACI-305R for hot weather placement protect all concrete from premature drying, excessive hot or cold temperature. AB concrete thicker or deeper than 4 inches shag be vibrated during placement. Use internal mechanical vibrators. Inserts, bolts, boxes, pipes, conduits, and other accessories shall be securely installed and inspected prior to placing concrete. Remove water, debris, wood, and loose concrete from space where concrete is to be placed. fc 3,000 psi minimum at 28 days, 5% sack minimum mix (special inspection is not required) Slump: 5 inches maximum water / cement: 0.47 maximum by weight air entrainment: 5%+/- 1 % 3/4-inch maximum size aggregate Cement: ASTM C150, normal -Type I or ASTM C595, Type IL Coarse and fine aggregate: ASTM C33 Water shall be dean and not detrimental to concrete. Admixtures containing chlorides shall not be used. Do not use calcium chloride, fly ash and related materials. Reinforcing steel shall conform to ASTM A615 Grade 60 new billet stock, deformed steel free of rust, scale or other bond -reducing coatings. Tie bars securely with #16 double annealed wire. EPDXY FOR ANCHORS AND DOWELS Use Simpson SET-XP or Hilti HIT HY-20OR adhesive system. Follow manufacturers instructions for all installation steps, including, injection tools, mixing nozzles, material handling and storing, substrate drilling and cleaning and adhesive injection. WOOD FRAMING AND LUMBER GRADING Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No. 16. Moisture content shall be maximum 19%. Wood framing details, not shown otherwise, shall be constructed to the minimum standards ofthe IBC and shall conform to Table 2304.10.1 Fastening Schedule of the IBC. Notations on drawings regarding connectors refer to products by the Simpson Tie Company Catalog C-C-2019. Where preservative treated lumber is cut or drilled after tmatmentl thecut surface shall be field treated with approved preservative by repeated brushingl dipping or soaking until the wood absorbs no more preservative. AsIDE COROUT NS RUCIION,LLC License #: INSIDOC886JR 4031 168T" St. SW Lynnwood, WA 98037 (206) 353-4937 Zone RS-6-- Corner N .N-.Flag Setbacks: Required Actual 66'10" Front ,! ---= �---- ..... Sides ---------- Rear ' 151 16'10"i -----------= Other ----------' ---- ----' Height �' L 25. exist.; =----------= APPROVED DBBZY PANNING Jul 08 024 A¢cx � k 5 arr� ...........................y VIEWED BY 'A' F EDMONDS DEPARTMENT: ........................ R E S U B 2024-0596 Jul 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT