RECBM D*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
CITY OF EDMONDS
DEPARTMENT
FILTER PARTS LIST
(See Fig. 7)
ITEM
PART NO
DESCRIPTION
NO.
1
51300C
FilterAssy-3000 Gal.
2
51469C
Assy-Filter & Brkt includes Fltr Head/
Mtg Brkt/John Guest Fittings/Screws
E
10*0
q____
3/8"
Water
Inlet
1
Filter Head Assembly
used after 01/01/2021
WATER FILTER EXPLODED VIEW
Fig. 7
REPLACEMENT PART KITS
PART NO.
DESCRIPTION
98543C
Kit - Electrical Package
98544C
Kit - EE Sensor
2000000503
Kit - Solenoid Valve Replacement
98546C
Kit -Aerator Replacement
98549C
Kit - Hardware & Waterway Parts
98631 C
Kit - Electrical Package 220V
2000000502
Kit - Solenoid Valve Replacement 220V
REVIEWED
BY
CITY OF EDMONDS
FIVE PIN -
CONNECTOR \
FOUR PIN �_MAIN
CONNECTOR
I.R. BOARD
[��Mm
LED BOARD
oo—
WHITE
RED]SOLENOID
• WHITE
NEUTRAL
BLACK
LINE VOLTAGE
GROUND
�T
L GREEN GROUND
U U Uf MALE
PLUG
FEMALE
RECEPTACLE
ELECTRICAL DIAGRAM
Fig. 8
PARTS LIST
PART NO.
DESCRIPTION
1000005855
115V Power Cord
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAMEAL 1 800 834 4816
PRINTED IN U.SA POUR OBTENIR DES PIECES, CONTACTEZ VOTRE DISTRI BUTEUR LOCAL OU COMPOSEZ LE 1 8008344816
IMPRESO EN LOS E E U U REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
IMPRIME AUX E -U NUMERO GRATIS DE SERVICIO 1 800 260 6640
INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1 800 260 6640
ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 - 630.574.8484• www.elkay.coni
Page 9 2000000485 (Rev. A- 01/22)
RECEIVE*1A EZWSM8-lA EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
Apr 03 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
`jE FYTCONTROL BOARD SOFTWARE
1) To verify the software program of the control board the unit will
need to be shut down and restarted. The chiller (if present) does
not need to be shut down and restarted.
2) The units lower panel must be open to access the power cord and
wall outlet.
3) Shut down the unit by unplugging the power cord from the wall
outlet or switching off the circuit breaker to the unit.
4) Restart the unit by plugging the power cord back into the wall
outlet or by switching on the circuit breaker to the unit.
5) Upon start up, the bottle count display will show the software
designation of BF11 or BF12.
ACCESSING THE PROGRAMMING BUTTON
1) To access the program button, open the lower panel. Reset button
is located at the lower right hand side of the top panel.
RESET THE FILTER MONITOR
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds until
the display changes then release. The display will change and
scroll through two messages:
"RST FLTR" — Reset Filter Monitor
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
3) When the display changes to 'RST FLTR", depress the button
again. The display will change to show "FLTR =". Depress the
button again and the display will show "FLTR =0"
4) The Green LED should be illuminated indicating that the visual
filter monitor has been reset.
SETTING RANGE OF THE IR SENSOR
1) Depress the program button for approximately 2 seconds until
the display changes then release. The display will change and
scroll through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
2) When the display changes to "SETTINGS', depress the button
again. The display will change to show
'RNG SET' - Range set for IR sensor.
"UNIT TYP" - Type of unit (REFRIG or NON-RFRG)
"FLT SIZE" - Select filter capacity
'RST BCNT' - Reset bottle count
3) When display shows 'RNG SET' push program button once the
display will show current value (can be 1 — 10) e.g. 'RNG = 3".
4) Once display shows current value push the program button to
scroll through value of 1 —10. Select the desired range setting,
"I " being closest to sensor and "10" being farthest away.
5) Once range is selected allow approximately 4 seconds to pass and
then the display will go back to bottle counter and be in run mode.
6) Test bottle filler by placing bottle or hand in front of sensor to
make sure water is dispensed.
SETTING UNIT TYPE
1) Depress the program button for approximately 2 seconds until the
display changes then release. The display will change and scroll
through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display will scroll
through the two messages above for three cycles and then default
back to bottle count and be back in run mode.
BF11 - BF12 PROGRAM
SETTING THE CONTROL BOARD
Continued from below:
2) When the display changes to "SETTINGS', depress the button again
The display will change to show
"RNG SET" - Range set for IR sensor.
"UNIT TYP" - Type of unit (REFRIG or NON-RFRG)
"FLT SIZE" - Select filter capacity
"RST BCNT - Reset bottle count
3) When display shows "UNIT TYPE" push program button once the
display will show current value. Can be REFRIG or NON-RFRG
4) Push button once to change value. Once value is selected the display
will show the new value. (Can be REFRIG or NON-RFRG)
'REFRIG' - stands for refrigerated product In this setting the flow rate is
estimated at 1.0 gallon per minute.
"NON-RFRG" - stands for nonrefrigerated product. In this setting the
flow rate is estimated at 1.5 gallons per minute. Both 'REFRIG' and
"NON-RFRG" simulate 1 bottle equal to 20 oz.
5) Allow approximately 4 seconds to pass and the display will return to
bottle counter and be in run mode.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds until the
display changes then release. The display will change and scroll
through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display will scroll through
the two messages above for three cycles and then default back to bottle
count and be back in run mode
2) When the display changes to "SETTINGS', depress the button again.
The display will change to show:
'RNG SET'- Range set for IR sensor.
"UNIT TYP" -Type of unit (REFRIG or NON-RFRG)
"FLT SIZE" - Select filter capacity
'RST BCNT' - Reset bottle count
If the button is not pushed again the display will scroll through the four
messages above for three cycles and return to run mode.
3) When display shows "RST BCNT' push program button once the
display will show current value, e.g. "0033183".
4) Once display shows current value push the program button once more
to reset back to 0. The display will show BTLCT = 0 for approximately 2
seconds and then return to run mode showing 00000000 bottles.
NOTE: Once the bottle count is reset to zero there is no way to
return to the previous bottle count.
5) Testing the bottle counter:
REFRIG units: Place bottle or hand in front of sensor for approximately
9 seconds to see bottle counter count 00000001,
(This is based on filling a 20 oz. bottle).
NON-RFRG units: Place bottle or hand in front of sensor for
approximately 6 seconds to see bottle counter count 00000001,
(This is based on filling a 20 oz bottle).
SETTING FILTER CAPACITY
1) Depress the program button for approximately 2 seconds until the
display changes then release. The display will change and scroll through
two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display will scroll through
the two messages above for three cycles and then default back to bottle
count and be back in run mode.
2) When the display changes to "SETTINGS', depress the button again.
The display will change to show:
'RNG SET'- Range set for IR sensor.
"UNIT TYP" - Type of unit (REFRIG or NON-RFRG)
"FLT SIZE" - Select filter capacity
'RST BCNT' - Reset bottle count
If the button is not pushed again the display will scroll through the four
messages above for three cycles and return to run mode.
3) When display shows "FLT SIZE" push program button once. The display
will show current value. Can be 3000GAL or 6000GAL
4) Push program button again to display the desired "FLT SIZE".
5) Allow approximately 4 seconds to pass and the display will return to
bottle counter and be in run mode.
2000000485 (Rev. A - 01 /22) Page 8
RECELVf6Vb*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
BF9 PROGRAM
CITY OF EDMONDS
DEVELOPMENT SERVICES S E TT I N
DEPARTMENT
VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the
unit will need to be shut down and restarted. The chiller
(if present) does not need to be shut down and restarted.
2) The units lower panel must be open to access the power
cord and wall outlet.
3) Shut down the unit by unplugging the power cord from the
wall outlet.
4) Restart the unit by plugging the power cord back into the
wall outlet.
5) Upon start up the bottle count display will show the
software designation of BF6, BF7, BF8, BF9 or BF11.
6) Reference the BF6-BF7-BF8-BF9 or BF11 instructions for
setting thecontrol board.
ACCESSING THE PROGRAMMING BUTTON
1) To access the program button the lower panel of the
unit must be must be opened. The programming button is
located at the bottom right corner of the upper panel.
This area of the unit is concealed by the lower panel.
RESET THE FILTER MONITOR
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
"RST FLTR" — Reset Filter Monitor
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count and
be back in run mode.
3) When the display changes to "RST FLTR", depress
the button again. The display will change to show
"FLTR =" Depress the button again and the display
will show "FLTR =0"
4) The Green LED should be illuminated indicating that
the visual filter monitor has been reset.
SETTING RANGE OF THE IR SENSOR
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
2) When the display changes to "SETTINGS', depress
the button again. The display will change to show
'RNG SET'- Range set for IR sensor.
"UNIT TYP" - Type of unit (REFRIG or NON-RFRG)
'RST BCNT' - Reset bottle count
3) When display shows `RNG SET' push program
button once the display will show current value
(can be 1 — 10) e.g. 'RNG = 3".
4) Once display shows current value push the
program button to scroll through value of 1 — 10.
Select the desired range setting.
5) Once range is selected allow approximately
4 seconds to pass and then the display will go
back to bottle counter and be in run mode.
6) Test bottle filler by placing bottle or hand in front
of sensor to make sure water is dispensed
G THE CONTROL BOARD
SETTING UNIT TYPE
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
2) When the display changes to "SETTINGS', depress
the button again. The display will change to show
"RNG SET% Range set for IR sensor.
"UNIT TYP" - Type of unit (REFRIG or NON-RFRG)
"RST BCNT - Reset bottle count
3) When display shows "UNIT TYPE" push program
button once the display will show current value
Can be REFRIG or NON-RFRG
4) Push button once to change value. Once value is
selected the display will show the new value.
(Can be REFRIG or NON-RFRG)
'REFRIG' - stands for refrigerated product. In this
setting the flow rate is estimated at 1.0 gallon per minute
"NON-RFRG" - stands for nonrefrigerated product.
In this setting the flow rate is estimated
at 1.5 gallons per minute.
Both 'REFRIG' and "NON-RFRG' simulate
1 bottle equal to 20 oz.
5) Allow approximately 4 seconds to pass and the display
will return to bottle counter and be in run mode.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
"RST FLTR" — Reset Filter Status LED
"SETTINGS" — System Settings Sub Menu
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
2) When the display changes to "SETTINGS', depress
the button again. The display will change to show
'RNG SET'- Range set for IR sensor.
"UNIT TYP" -Type of unit (REFRIG or NON-RFRG)
'RST BCNT' - Reset bottle count
If the button is not pushed again the display will scroll
through the three messages above for the cycles and
return to run mode.
3) When display shows "RST BCNT' push program button
once the display will show current value e.g. "00033183".
4) Once display shows current value push the program
button once more to reset back to 0. The display will
show BTLCT = 0 for approximately 2 seconds and
then return to run mode showing 00000000 bottles.
5) Testing the bottle counter:
REFRIG units: Place bottle or hand in front of sensor
for 9 4 seconds to see bottle counter count 00000001.
(This is based on filling a 20 oz. bottle)
NON-RFRG units: Place bottle or hand in front of sensor
for 6.25 seconds to see bottle counter count 00000001.
(This is based on filling a 20 oz bottle)
Page 7 2000000485 (Rev. A - 01/22)
RECEIVE*1A EZWSM8''1A EZWSM8*2A LZWSMD"1A LZWSM8-lA LZWSM8"2A
Apr 03 2024 BF6-BF7-BF8 PROGRAMS
CITY OFE
DEVELOPMMENTTSERVICES SETTING THE CONTROL BOARD
ERVI
DEPARTMENT
VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the
unit will need to be shut down and restarted. The chiller
(if present) does not need to be shut down and restarted.
2) The units lower panel must be open to access the power
cord and wall outlet.
3) Shut down the unit by unplugging the power cord from the
wall outlet.
4) Restart the unit by plugging the power cord back into the
wall outlet.
5) Upon start up the bottle count display will show the
software designation of BF6, BF7, BF8, BF9 or BF11.
6) Reference the BF6-BF7-BF8-BF9 or BF11 instructions for
setting thecontrol board.
ACCESSING THE PROGRAMMING BUTTON
1) To access the program button the lower panel of the
unit must be must be opened. The programming button is
located at the bottom right corner of the upper panel.
This area of the unit is concealed by the lower panel.
RESET THE FILTER MONITOR
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through three messages:
"RST FLTR" — Reset Filter Status LED
"RST BCNT" — Reset Bottle Count
"RNG SET" — Range Set for IR Sensor
If the program button is not pushed again the display
will scroll through the three messages above for
three cycles and then default back to bottle count and
be back in run mode.
3) When the display changes to 'RST FLTR", depress
the button again. The display will change to show
"FLT=". Depress the button again and the display will
show "FLTR=O".
4) The green LED should now be illuminated indicating
that the visual filter monitor has been reset.
SETTING RANGE OF THE IR SENSOR
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through three messages:
"RST FLTR" — Reset Filter Status LED
"RST BCNT" — Reset Bottle Count
"RNG SET" — Range Set for IR Sensor
2) If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
3) When display shows "RNG SET' push program button
once the display will show current value
(can be 1 — 10) e.g. "RNG = 3".
4) Once display shows current value push the program
button to scroll through value of 1 — 10. Select the
desired range setting.
5) Once range is selected allow approximately 4 seconds
to pass and then the display will go back to bottle counter
and be in run mode.
6) Test bottle filler by placing bottle or hand in front of
sensor to make sure water is dispensed.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
"RST FLTR" — Reset Filter Status LED
"RST BCNT" — Reset Bottle Count
"RNG SET" — Range Set for IR Sensor
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
2) When the display changes to 'RST BCNT", depress the
button again. The display will change to show current
bottle count value e.g. "00033183"
3) Depress the button again and the display will change to
"BTLCT=O" for approximately 2 seconds and then return
to run mode displaying 00000000.
4) You can test the bottle counter by running water
approximately 5 seconds to see bottle counter advance 1
2000000485 (Rev. A - 01/22) Page 6
RECELVER*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
EWF3000 WATERSiiiNWZY STRAINER INSTALLATION (Fig. 5):
DEVELOPMENT SERVICES
17. For non-fmltisiredEunits: Install a shut-off valve and union connection to building water supply (valve and union not provided). Turn on the water
supply and flush the line thoroughly. Turn off water supply. Install the in -line strainer between the valve and the chiller. The in -line strainer is not
installed on filtered units.
18. Connect water supply line: Connect 3/8" shut-off valve to 3/8" copper tubing to inlet of strainer. Connect water line from BF station by inserting
the'/d' O.D poly tubing into union on the chiller outlet. Turn on water supply and check for leaks
19. Place Chiller on Shelf: When mounting unit in a cavity or behind a wall maintain a minimum space of 4" (102mm) on top, sides and a depth of
12" (305mm).
20. Remove Chiller Front panel:Remove the (10) screws securing chiller front panel.
21. Connect electrical to chiller: Make sure power supply is identical in voltage, cycle and phase to that specified on cooler serial plate. Never wire
Compressor directly to the power supply. While chiller panel is off, adjust cold control if needed. Replace chiller panel: Using the (10) screws
re -secure the panel.
22. Turn on water supply: Turn on the water supply, plug unit into wall (power cord not supplied on 220V models) and activate the electronic eye
on in -wall bottle filler until approximately 1 gallon of water is dispensed. Be sure to reinstall fuse to the circuit or switch the circuit breaker back
to the "ON" position. Once power is applied to Bottle Filler, the GREEN LED LIGHT and/or LCD Bottle Counter should illuminate, the green light
showing good filter status Please. note that the electric eye activation times out at 20 seconds and will need to be activated repeatedly until 1
gallon has been passed. This flushing procedure purges air and fine carbon particles from filter and strainer. When 1 gallon of water has been
purged through the bottle filler, carefully inspect all water connections for leaks.
23. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses.
24. Close and lock the lower panel in place using two set screws (provided) on the side of the panel.
25. Installation Complete.
UPPER PANE
DRAIN LOCATIO
LOWER PANEL
OUNTING FRAME
ALL BOX RECEPTACLE
JNCTION BOX
DCATION
'OWER SUPPLY
'ORD
FILTER LOCATION
(OPTIONAL)
Page 5 2000000485 (Rev. A - 01/22)
RECEID*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8"1A LZWSM8*2A
Apr 03 2024 INSTALLATION INSTRUCTIONS
CITY OF EDMONDS
DEVELOPMENT SERVICES
1. Install m8V rfflh *Tame and chiller shelf. See mounting frame instructions.
2. Mount the upper BF panel to the mounting frame: Mount upper panel by aligning holes in the hinge brackets with holes in the mounting frame
(three places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the side and bottom of the
panel align with the slots on the mounting frame. Also verify that the panel is hanging high enough that it covers the top of the mounting frame.
3. Mount the lower Chiller panel to the mounting frame: Mount the lower panel by aligning holes in the hinge brackets with holes in the mounting
frame (three places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the side of the panel
align with the slots on the mounting frame. If adjustments need to be made, open the doors to make adjustments. Open panels for adjustments.
Loosen the (4) screws on the hinges of each panel and adjust accordingly and then re -tighten screws. Close and Lock the top panel in place
using two set screws (provided) on the side of the panel, and a%x 20 bolt through the front of the panel into the nut in the frame.
4. Attach drain: Attach the drain fittings to drain tube. Attach elbow to p-trap and cut waste tube to required length using plumbing hardware and
trap as a guide.
5. Install remote chiller: See chiller instructions. Remove protective caps from water lines on chiller.
EWF3000 WATERSENTRY PLUS FILTER INSTALLATION (Fig. 5): (Filter units only. For non -filtered units proceed to step 15)
NOTICE: Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system
CAUTION: If supply pressure will ever exceed 100 psi, install a pressure regulator set to 100 psi or below.
DO NOT ATTACH HOT WATER LINE TO FILTER HEAD.
Filter kits must be installed in compliance with all state and local laws and regulations governing the installation and use of this product
Maximum inlet water temperature: 100°F (38°C).
See filter instructions for filter head assembly.
6. Connect Filter Kit: Using the filter mounting bracket and screws supplied, mount filter head using the (3) screw holes on the side of the chiller.
Allow enough room under the filter head for the installation and removal of the filter cartridge (13" minimum). To make tube connections on the
filter head, loosen locknut. Push the tube end past both O-rings to a positive stop in the filter head recess - approx. 1 ". Screw the locknut hand
tight to seal (See Fig. 5). Ends of tubing must be cut square and free of burrs and sharp ends that could cut or nick the O-rings.
7. Connect filter water outlet: Connect the outlet of the filter head to the inlet of the chiller using the'/d' O.D. poly tubing and%" elbow
union supplied.
8. Place Chiller on Shelf: When mounting unit in a cavity or behind a wall maintain a minimum space of 4" (102mm) on top, sides and a
depth of 12" (305mm).
9. Connect bottle filter line: Connect water line from BF station by inserting the%" O.D. poly tubing into union on the chiller outlet.
10. Remove Chiller Front panel: Remove the (10) screws securing chiller front panel.
11. Connect electrical to chiller: Make sure power supply is identical in voltage, cycle and phase to that specified on cooler serial plate. Never wire
Compressor directly to the power supply. While chiller panel is off, adjust cold control if needed.
12. Replace chiller panel: Using the (10) screws re -secure the panel.
13. Plug bottle filler into wall box receptacle.
14. Install a shut-off valve: Install a shut-off valve and union connection to building water supply (valve and union not provided). Connect 3/8"
shut-off valve to 3/8" copper tubing inlet of filter head.
15. Install filter cartridge: remove filter from carton, remove protective cap, and attach filter to filter head by firmly inserting into head and rotating
filter clockwise.
16. Go to step 18.
PLUMBING DIAGRAM
Fig. 5
ITO BOTTLE FILLER TO BOTTLE FILLER
INLET
STRAINER
• ,CHILLER
INLET .
CHILLER FILTER . o
FILTERED NON FILTERED
2000000485 (Rev. A - 01 /22) Page 4
RECEk *1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
/Apr U3 LUL4
' DEVCITY 0
ELOPZB
m8P*, LZWSMDP* EZWSM8P*, EZWSMDP* ROUGH -IN
DEPARTMENT
1 1/8" (79mm )
( 29mm) 1/4" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
DOUBLE STUD OR 3" (76mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
FILTER LOCATION
4"
U—(102mm)
9 m
( 502m 1
8 ( 203.2MM ) MINIMUM
FOR DRAIN CONNECTION
1 3/16"
17 3I8"
3116"
AND ACCESS TO
( 3Omm)
(441mm)
(3Omm)
BOTTLE FILLER
ELECTRICALS
ACTIVATION
oo, BACK WALL LINE
SENSOR
JUNCTION BOX
21 15116"
(557mm)
2 7/8"
(73mm)
LOCATION
NOTE: NON —REFRIGERATED
1-1/4" (32MM)
MODELS (WITHOUT CHILLER)
WASTE TUBE
DO NOT
INCLUDE LOUVERS
FURNISHED
18 718-
88mm )
3211116
( 831 mm)
["IF 1
i
1
27'
( 682mm f ELECTRICAL
273!M
t 693.74hIM f
u u
18 fit$
INLET
25 i/4
25 7/8"
( 481mm 1
t642�1
19mmf(657mm1
t8
FINISHED FLOOR
FINISHED FLOOR
1 1l8"
( 29mm)
4 112'
( 117mm )
( 279mm )
Fig. 4
Page 3 2000000485 (Rev. A - 01 /22)
RECEId/01"1A EZWSM8-lA EZWSM8*2A LZWSMD*1A LZWSM8-lA LZWSM8.2A
Apr 03 2024
CITY OPED
DEVELOPMENT ER�� S"tZWSM8*, LZWSMD* EZWSM8*, EZWSMD* ROUGH -IN
DEPARTMENT
19 3/4"
( 502mm )
1 3/16" 17 318"
(30mm) (441mm )
ACTIVATION C
SENSOR
1 3116"
(30mm )
1518mm )
NOTE: NON -REFRIGERATED
MODELS (WITHOUT CHILLERI
DO NOT INCLUDE LOUVERS
38I7/8 I Fl
I
� 1 1
( 987mm )
32 11116"
(831mm) 20
LLILJLJ(519mm)
_j
FINISHED FLOOR
1 1/8" (79mm )
( 29mm) —i 1/4" OD. TUBE CONNECT
(
318" O.D. TUBE CONNECT CHILLER WATER OUTLET)
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
8 I/8" 9 318"
(206mm ) (238mm )
DOUBLE STUD OR 3" 176mm) 11
BETWEEN MOUNTING FRAMES - (4,
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
2 7/8"
( 73mm )
1682rnn) I ELECTRICAL
251/4" INLET
( 642mm )
Fig. 3
FINISHED FLOOR
1 118"
(29mm )-
FILTER LOCATION
(102 ml
B" (203MM) MINIMUM
FOR DRAIN CONNECTION
AND ACCESS TO
BOTTLE FILLER
ELECTRICALS
BACK WALL LINE
JUNCTION BOX
LOCATON
1-114" 132MMI
WASTE TUBE
FURNISHED
27 3/8-
( 693 74mm )
25 7/8'
3 I /2" (657mm 1
( 89mm )
"
( 111217mm )
(279mm 1 4
2000000485 (Rev. A - 01 /22)
Page 2
RECEIRVE b*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
' CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
E L KAY
Installation & Use Manual
ezH2O0 In Wall Bottle Filling Station
LZWSM8*
EZWSM8*
Installer
LZWSMD* LZWSM8P*
EZWSMD* EZWSM8P*
a
LZWSMDP*
EZWSMDP*
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICALAND
OTHER APPLICABLE CODES. After installation, leave these instructions inside the
fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BYAN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSESA METALLIC TASTE ORAN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE
MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING
SYSTEM. WE SUGGEST THAT THE BOTTLE FILLER BE PROTECTED BYA GROUND FAULT CIRCUIT
INTERRUPTER (GFCI)
114" O D TUBE
WATER INLET 3/8" O.D. TUBE CONNECT BUILDING WATER
TO COOLER COLD WATER SUPPLY INLET
NOTE: WATERFLOW
DIRECTION SERVICE STOP
Fig. 1 (NOT FURNISHED)
OPERATION OF QUICK CONNECT FITTINGS
PUSH IN
TUBEISSECURED I
PUSH IN
COLLETSIMPLY
TUBE TO ATTACH
IN POSITION
TO-
w.'...n�
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
Fig, 2 RELEASE TUBE
Patent zurn-elkay.comlpatents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
DADVERTENCIA: Cancer y dano reproductivo - www.P65Warnings.ca.aov
dsAVERTISSEMENT: Cancer et effets nefastes sur la reproduction - www.P65Warnings,ca.gov
Page 1 2000000485 ( Rev. A - 01 /22 )
RECEIVED
Apr 03 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
RECEIVED
Apr
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
INSTALLATION INSTRUCTIONS
FOR IN -WALL PANEL REPLACEMENT
Note: Replacing the lower panel on wall frames
manufactured on or before June/2016 may require
a 28915C hinge.
1. Unpack & inspect new panel and hinge assembly. _
2. Remove and discard (recycle) old panel & hinges.
3. Retain removed fasteners for future use. „r
4. Attach hinge assembly to new panel using saved screws. -
5. Mount hinge to wall frame using saved screws from previous '
installation. _
6. Lower hinge may only line up with two holes in wall frame
(this is normal).
7. If necessary, all four holes of the lower hinge can be utilized by
drilling through the existing frame. -
8. Close panel & verify that lock brackets on opposite side panel
align with slots on the mounting frame.
9. Also, verify gap between panels is properly spaced & that panel
covers bottom edge of wall frame.
10. If adjustments need to be made; open door, loosen hinge screws,
adjust accordingly & retighten screws
aww-
A
•u
11. Choose an appropriate slot to control the
gap between panels.
REPAIR SERVICE INFORMATION CALL TOLL FREE NUMBER 1.800.260.6640