APPROVED BLD2024-0255+Plumbing_Plan+2.26.2024_11.35.18_AM+4082619KRUGER BUILDING TENANT IMPROVEMENT PLUMBING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION LINE TYPE DESCRIPTION LINE TYPE DESCRIPTION E END CAP Ik BALL VALVE PT PRESSURE TRANSDUCER DOMESTIC COLD WATER GRWUG GREY WATER WASTE UNDERGROUND - D CONCENTRIC REDUCER I ►'J I BUTTERFLY VALVE O AREA DRAIN - - DOMESTIC HOT WATER GRW GREY WATER WASTE FLOW ARROW CHECK VALVE ® FLOOR CLEANOUT - - - DOMESTIC HOT WATER RETURN GREY WATER WASTE SUDS D PIPE DROP T� I`LJ'I CIRCUIT SETTER ® FLOOR DRAIN RECLAIMED/RECYCLED WATER SEWAGE EJECTOR DISCHARGE RCW PIPE RISER >< GATE VALVE O FLOOR SINK, SQUARE OR ROUND INDUSTRIAL COLD WATER SUMP PUMP DISCHARGE CW TEE UP I T GLOBE VALVE ® HUB DRAIN INDUSTRIAL HOT WATER CD CONDENSATE DRAIN IHW TEE DOWN NEEDLE VALVE O OVERFLOW DRAIN IHWR INDUSTRIAL HOT WATER RETURN Ar ARGON i I i UNION RELIEF VALVE ® ROOF DRAIN IRRIGATION WATER CA COMPRESSED AIR IRR 30 P-TRAP PRESSURE REDUCING VALVE a ROOF RECEPTOR TEMPERED WATER CDA CLEAN DRY AIR TW HOSE BIBB PRESSURE SUSTAINING VALVE WALL CLEANOUT TRAP PRIMERS IA LAB / INSTRUMENT AIR TP GAS COCK MOTORIZED 2W-CV O INDICATES ITEMS FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR FILTERED WATER N2 NITROGEN FW GM GAS METER MOTORIZED BUTTERFLY 2W-CV O INDICATES ITEMS FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR SOFT COLD WATER 02 OXYGEN SFT AQUA STAT MOTORIZED 3W-CV -H+-) ELECTRICAL EQUIPMENT CONNECTION LOCATION BY ELECTRICAL CONTRACTOR NATURAL GAS SYSTEMS SG SPECIALTY GASES NG I B_F P-1 BACKFLOW PREVENTER DRAIN VALVE WITH END CAP xX-1 PLUMBING FIXTURE CALLOUT MEDIUM PRESSURE GAS SYSTEMS LVAC LAB VACUUM MPG DOUBLE CONTAINMENT PIPE SLEEVE AIR VENT - AUTO WCO-1 PLUMBING FIXTURE CALLOUT x1.5 HIGH PRESSURE GAS SYSTEMS VAC PROCESS VACUUM HPG ® FLEX CONNECTION AIR VENT - MANUALX PLUMBING RISER TAG - - NGV - - - NGV NATURAL GAS VENT HV HOUSE VACUUM HAMMER ARRESTOR y MOTORIZED BUTTERFLY 3W-CV (DIVERTING) Q PLUMBING EQUIPMENT TAG SANITARY WASTE UNDERGROUND DIR DEIONIZED WATER RETURN FM FLOW METER TURBINE f� • If • / MOTORIZED BUTTERFLY 3W-CV (MIXING) # ACX xx DETAIL BUBBLE SANITARY WASTE DIS DEIONIZED WATER SUPPLY ® PUMP ,{� BALL VALVE WITH HOSE CONNECTION ® POC SANITARY WASTE SUDS ROR REVERSE OSMOSIS RETURN 1 THERMOMETER PRESSURE GAUGE WITH SHUT-OFF VALVE X% PIPE SLOPE - - - - - - - - - - - - - - SANITARY VENT UNDERGROUND ROS REVERSE OSMOSIS SUPPLY ® VACUUM BREAKER I I PLUG VALVE ( ( REVISION CLOUD - - - - - - - - - - - - - - SANITARY VENT PCWR PROCESS COOLING WATER RETURN INSULATION MIXING VALVE REVISION DELTA STORM DRAIN UNDERGROUND PCWS PROCESS COOLING WATER SUPPLY TEMPERATURE SENSOR & THERMO WELL SOLENOID VALVE O SHEET NOTE STORM DRAIN LWUG LAB WASTE UNDERGROUND FM FLOW METER INLINE SEISMIC SHUT-OFF VALVE OVERFLOW DRAIN UNDERGROUND LW LAB WASTE T PETE'S PLUG STRAINER WITH BLOW DOWN VALVE OVERFLOW DRAIN - - - LV - - - LV - - - LV - LAB VENT ® AUTO FLOW CONTROL STRAINER GREASE WASTE GW ABBREVIATIONS ABBR. DESCRIPTION ABBR AP ACCESS PANEL GPM AFF ABOVE FINISHED FLOOR GD AHJ AUTHORITY HAVING JURISDICTION GW AD AREA DRAIN IE AW AUTOMATIC CLOTHES WASHER IW BFF BELOW FINISHED FLOOR JS BOP BOTTOM OF PIPE BT BATHTUB KS COTG CLEAN OUT TO GRADE LV CTE CONNECT TO EXISTING MS DCW DOMESTIC COLD WATER MH DIA,O DIAMETER DN DOWN N DHW DOMESTIC HOT WATER NC DHWR DOMESTIC HOT WATER RETURN NIC NO E EXISTING NTS ED EMERGENCY DRAIN NPT EL ELEVATION EWH ELECTRIC WATER HEATER OD EX EXPANSION TANK PD F FUTURE POC FCO FLOOR CLEAN OUT PSI FD FLOOR DRAIN FF FINISH FLOOR PSIG FS FLOOR SINK PRV APPLICABLE CODES DESCRIPTION ABBR. DESCRIPTION WASHINGTON PLUMBING PROJECTS: GALLONS PER MINUTE R RELOCATED GUTTER DRAIN RD ROOF DRAIN ALL WORK SHALL BE IN FULL ACCORDANCE WITH APPLICABLE GREASE WASTE RCW RECYCLED WATER LOCAL, STATE, AND FEDERAL CODES, LAWS AND REGULATIONS ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WI' INVERT ELEVATION SD STORM DRAIN BUT NOT LIMITED TO: INDIRECT WASTE SOV SHUT-OFF VALVE SH SHOWER • 2018 INTERNATIONAL BUILDING CODE WITH WA AMENDME JANITOR SINK SK BREAK ROOM/COFFEE SINK • 2020 NATIONAL ELECTRICAL CODE WITH WA AMENDMENT SS SANITARY SEWER/SANITARY WASTE • 2018 INTERNATIONAL MECHANICAL CODE WITH WA AMEN[ KITCHEN SINK • 2018 UNIFORM PLUMBING CODE WITH WA AMENDMENTS TD TRENCH DRAIN • 2018 WASHINGTON STATE ENERGY CODE LAVATORY TP TRAP PRIMER • 2018 INTERNATIONAL FIRE CODE WITH WA AMENDMENTS TYP TYPICAL MOP SINK MANHOLE U URINAL NEW V VENT ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING NORMALLY CLOSED V VESSEL ADDITIONAL GUIDELINES WHERE REQUIRED BY CODE: NOT IN CONTRACT VTR VENT THROUGH ROOF NORMALLY OPEN VIF VERIFY IN FIELD • SHEET METAL AND AIR CONDITIONING CONTRACTORS NOT TO SCALE NATIONAL ASSOCIATION (SMACNA) NATIONAL PIPE THREAD WCO WALL CLEAN OUT • AMERICAN SOCIETY OF HEATING, REFRIGERATION AND WC WATER CLOSET AIR-CONDITIONING ENGINEERS (ASHRAE) OVERFLOW DRAIN WM WATER METER • AMERICAN SOCIETY OF PLUMBING ENGINEERS (ASPE) • AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) PLANTER DRAIN • AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) POINT OF CONNECTION • NATIONAL FIRE PROTECTION AGENCY (NFPA) POUNDS PER SQUARE INCH • OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) POUNDS PER SQUARE INCH(GAUGE) PRESSURE REDUCING VALVE SCOPE OF WORK 1. REPLACE (2) LIKE -FOR -LIKE WATER HEATERS. 2. REPLACE (1) DRINKING FOUNTAIN WITH (1) ADA HI-LO DRINKING FOUNTAIN. H, City Of Edmonds TS Building Department rnd�c PLUMBING Addresa 21600 HIGHWAY 99 Owner KRUGER CLINIC Approved Date 03/19/2024 Buildinc, Official Erg Permit 111 ---------------------- umber -------ml I--mnq4-Qq DRAWING INDEX DRAWING INDEX KEY: NOT INCLUDED WITH ISSUE NEW OR REVISED O NO CHANGES C) O U LLI LLI Z U _ ~ W I_ LU � N o N CDNO. SHEET DRAWING TITLE P0.00 COVER SHEET P0.01 CONSTRUCTION REQUIREMENTS, EQPT. SCHEDULES P2.01 1ST FLOOR DEMO & PLUMBING PLAN, PL DETAILS VICINITY MAP Stevens Court Apartments 19 F2'76t�h'�S, S�WI -Id )onds iopedic Center 216th St SW Swedish Oncology Social Work - Edmonds 1P 2 6th St S•W IC 9 Sahn- I JeTT 0Sche Chan Emerald City Engineers, Inc � I 5300 DENVER AVENUE SOUTH SEATTLE, WASHINGTON 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BYAND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC. (`ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BYACCO IN WRITING. ACCO CANNOTACCEPTANYLIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. EXPIRES: 11-28-2024 ALL ORK SUBJECT O FIELD IN ECTION FOR OD COMPLIANC IP�OAN�D JOB SITEI L1 02/23/2024 No. Date Revisions PERMIT SET Description 7Project KRUGER BUILDING TENANT IMPROVEMENT 21600 HIGHWAY 99 EDMONDS, WA 98026 MN IBy Title RECEIVED COVER SHEET Feb 26 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M.NOYES T.TOUTONGHI Designed By Checked By M.NOYES S. ELLIS Drawn By Project Manager 60940540 AS NOTED Job Number Scale PO.00 PIPING VOLUME AND MAXIMUM PIPING LENGTHS (WSEC C404.3.1) NOMINAL PIPE SIZE (INCHES) VOLUME (LIQUID OUNCES PER FT LENGTH) MAXIMUM PIPING LENGTH PUBLIC LAVATORY FAUCETS OTHER FIXTURES AND APPLIANCES 1/4 0.33 6 50 5/16 0.5 4 50 3/8 0.75 3 50 1/2 1.5 2 43 5/8 2 1 32 3/4 3 0.5 21 7/8 4 0.5 16 1 5 0.5 13 1 1/4 8 0.5 8 1 1/2 11 0.5 6 2 OR LARGER 18 0.5 4 MECHANICAL ID AND PLUMBING PIPE LABELLING SYMBOL SERVICE MARKER LETTERING MARKER COLOR LETTER COLOR DCW DOMESTIC COLD WATER POTABLE COLD WATER GREEN WHITE DHW DOMESTIC HOT WATER POTABLE HOT WATER GREEN WHITE DHWR DOMESTIC HOT WATER RETURN POTABLE HOT WATER RETURN GREEN WHITE LCW* LAB COLD WATER NON -POTABLE COLD WATER YELLOW BLACK LHW* LAB HOT WATER NON -POTABLE HOT WATER YELLOW BLACK LHWR* LAB HOT WATER RETURN NON -POTABLE HOT WATER RETURN YELLOW BLACK SW SANITARY WASTE SANITARY WASTE YELLOW BLACK SV SANITARY VENT SANITARY VENT YELLOW BLACK NOTES: 1. Install labell on piping mains every 40 ft and at all equipment connections. 2. Wrap piping label end with flow arrow tape, letter sizing per pipe size. 3. All labelling shall be per upc 601.3 / WAC. 4. *Additional labelling shall be per upc 601.3.2 / WAC - Yellow label w/ black letters - CAUTION: NON -POTABLE WATER, DO NOT DRINK PIPING INSULATION REQUIREMENTS (PER 2018 WSEC/SEC REQUIREMENTS SECTION C403.10.3) FLUID OPERATING TEMP RANGE (°F) INSULATION CONDUCTIVITY NOMINAL PIPE SIZE (IN.) CONDUCTIVITY BTU*IN/(H*FT2*°F) MEAN RATING TEMP, °F <1 1 TO < 1 1 1 2 TO < 4 4 TO < 8 > 8 > 350 0.32 - 0.34 250 4.5 5.0 5.0 5.0 5.0 251 -350 0.29 - 0.32 200 3.0 4.0 4.5 4.5 4.5 201 - 250 0.27 - 0.30 150 2.5 2.5 2.5 3.0 3.0 141 - 200 0.25 - 0.29 125 1.5 1.5 2.0 2.0 2.0 105 - 140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 1.5 40 - 60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0 < 40 0.20 - 0.26 75 0.5 1.0 1.0 1.0 1.5 NOTES: 1. FOR PIPING SMALLER THAN 1 1/2" AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1" SHALL BE PERMITTED BUT NOT TO A THICKNESS LESS THAN 1". 2. INSULATION IS NOT REQUIRED FOR CONDENSATE DRAIN PIPING FROM A DX COOLING COIL PER WSEC/SEC 403.10.3 EXCEPTION 3. IT IS RECOMMENDED THAT IF THE DRAIN PIPING IS LOCATED WITHIN A PLENUM THAT IS NOT USED AS A RETURN AIR PATH, OR OTHER UNCONDITIONED SPACE WITH LIMITED AIRFLOW, THE DRAIN PIPE SHOULD BE INSULATED WITH 0.5" THICK INSULATION TO PREVENT CONDENSATION ON THE OUTSIDE OF THE PIPE. PLUMBING PIPING SCHEDULE SERVICE LOCATION SIZE PIPE TYPE MAT'L STD FITTINGS JOINTS WORKING TEST PRESS. PRESS. COLD WATER ABV GRADE Y4' - 2" COPPER TYPE L ASTM B88 WROUGHT COPPER WATER SAFE SOLDER 80 PSIG 150 PSIG HOT WATER COPPER TYPE L ASTM B88 TEE DRILL WATER SAFE SOLDER COPPER,BRASS HOT WATER CIRC COPPER TYPE L ASME B16.51 COPPER ALLOY PRESS 2Y2' AND COPPER TYPE L ASTM B88 WROUGHT COPPER SILVER BRAZED ABOVE TEE DRILL WATER SAFE SOLDER OR FLANGED SANITARY WASTE ABV GRADE 1Y4" AND ABV COPPER DWV ASTM B306 COPPER DWV 50/50 SOLDER AMBIENT 10 FT H2O NO HUB CI CISPI 301 VENT NO HUB Cl NO HUB SANITARY WASTE BLW GRADE 1Y4" AND ABV SCH 40 PVC ASTM D1785 SCH 40 PVC SOCKET WELD AMBIENT 10 FT H2O VENT INDIRECT DRAIN ABV GRADE Yy, _ 1 COPPER TYPE L ASTM B88 WROUGHT COPPER 50/50 SOLDER AMBIENT N/A 1Yz" AND ABV COPPER DWV ASTM B306 WROUGHT COPPER 50/50 SOLDER WATER HEATER SCHEDULE ELECTRICAL DATA GAS TAG LOCATION MANUFACTURER MODEL No. DIMENSIONS GPH @ 80°F RISE EWT LWT SUPPLY STORAGE (GAL) WEIGHT (LBS) REMARKS E-POWER KW V PH (Y/N) (btu) 105C MECHANICAL BRADFORD WHITE M-11-120-18-3SF-37 64-1/2"x 30-1/4"Q 93 120 18 1480 DEMO EXISTING UNIT. REPLACE WITH LIKE -FOR -LIKE. 106D MECHANICAL AO SMITH DVE 120 62-114"x 29-112"0 93 120 1 1385 DEMO EXISTING UNIT. REPLACE WITH LIKE -FOR -LIKE. CEHD WITH 3 ELEMENTS. 208 VOLT CONVERSION EWH-1 105C MECHANICAL BRADFORD WHITE CEHD120A183*CF 64-11/16" x 30-1/4"0 93 40 120 18 208 3 N N 119 1425 KIT: 415-51043-78. DIVERSITECH UC3636-3 R-10 MIN PAD. FIELD VERIFY 208V/3P AVAILABLE ONSITE. MEETS ASHRAE/IES 90.1 STANDARD. 150 PSI RATING. GLASS -LINED INTERIOR. ASME RATED T&P EWH-2 106D MECHANICAL AO SMITH DRE-120-18 62-1/4" x 29-1/2" 92 40 120 18 208 3 N N 119 1385 RELIEF VALVE. DIVERSITECH UC3636-3 R-10 MIN PAD. FIELD VERIFY 208V/3P AVAILABLE ONSITE. PLUMBING FIXTURE SCHEDULE ROUGH -IN TAG DESCRIPTION ITEM MANUFACTURER MODEL No. REMARKS WASTE VENT DHW DCW RCW FLOWRATE MOTION ACTIVATED INDOOR WALL MOUNT ADA HI-LO STAINLESS STEEL FILTERED WATER COOLER SHALL INCLUDE AN ASHRAE COMPLIANT, HERMETICALLY SEALED R-134A REFRIGERATION SYSTEM WITH THERMOSTAT. ADA COMPLIANT TO ICC Al17.1, CSA B651, DOSS DF-1 DRINKING FOUNTAIN FOUNTAIN: HAWS 1202SFH 2" 2" - 1/2" - 0.5 GPM 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHEN PROPERLY INSTALLED. ASHRAE 18 COMPLIANT CHILLING CAPACITY OF 8.0 GALLON PER HOUR OF 50 DEGREE DRINKING WATER, BASED ON 80 DEGREE INLET WATER AND 90 DEGREE AMBIENT TEMPERATURE. 115 VOLT, 350 WATT. DIMENSIONS: (L x W x H) 18-3/4" x 34-1/16" x 31-3/4". PLUMBING GENERAL NOTES EXCEPT AS MODIFIED BY A WRITTEN CONTRACT SIGNED BY ACCO MECHANICAL CONTRACTORS (THE "DESIGN -BUILDER"), THE DRAWINGS, SPECIFICATIONS, AND OTHER DOCUMENTS, INCLUDING THOSE IN ELECTRONIC FORM PREPARED BY OR FOR AND/OR FURNISHED BY DESIGN -BUILDER ARE "INSTRUMENTS OF SERVICE." THE DESIGN -BUILDER, DESIGN -BUILDER'S CONSULTANTS AND OTHER PROVIDERS OF PROFESSIONAL SERVICES INDIVIDUALLY SHALL RETAIN A FULLY PREPAID, UNRESTRICTED, PERPETUAL LICENSE IN THE INSTRUMENTS OF SERVICE AS WELL AS ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT IN THOSE INSTRUMENTS OF SERVICE FURNISHED BY THEM. THE INSTRUMENTS OF SERVICE FURNISHED BY DESIGN -BUILDER ARE FOR SOLE USE BY DESIGN -BUILDER IN CONSTRUCTING THE SUBJECT PROJECT. THE INSTRUMENTS OF SERVICE ARE NOT SUITABLE FOR BIDDING OR CONSTRUCTING BY OTHER CONTRACTORS. THEREFORE, IF DESIGN -BUILDER IS NOT RETAINED AS THE DESIGN -BUILD CONTRACTOR TO PERFORM THE WORK DEPICTED IN THE INSTRUMENTS OF SERVICE,WITHOUT THE PRIOR WRITTEN CONSENT OF THE DESIGN BUILDER, THE INSTRUMENTS OF SERVICE MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE EXCEPT FOR GENERAL REFERENCE. DESIGN -BUILDER DISCLAIMS ALL LIABILITY FOR ANY ADAPTATION, MODIFICATION, OR INTERPRETATION OF THE INSTRUMENTS OF SERVICE OR FOR ANY OTHER UNAUTHORIZED USE OF THESE INSTRUMENTS OF SERVICE. THESE DOCUMENTS WERE PREPARED FOR CONSTRUCTION BY DESIGN -BUILDER ONLY. DESIGN -BUILDER DEVELOPED THESE DOCUMENTS WITH ENGINEERING SOLUTIONS AND CONSTRUCTION MEANS AND METHODS UNIQUE TO DESIGN -BUILDER FOR THE CONSTRUCTION OF THE SUBJECT PROJECT AND ARE NOT APPROPRIATE FOR OTHERS TO BID OR BUILD FROM. IN ADDITION, THESE DRAWINGS WERE DEVELOPED FROM INFORMATION MADE KNOWN TO DESIGN -BUILDER AS OF THE DATE OF THE DOCUMENT AND WOULD NOT INCLUDE LATER CHANGES ALL PLUMBING FIXTURES ARE TO BE LOCATED AND MOUNTED PER THE ARCHITECTURAL FLOOR PLANS AND ELEVATIONS. 3. HOT WATER SUPPLY AND RECIRCULATING PIPING TO BE INSULATED PER THE PIPE INSULATION REQUIREMENTS TABLE ON THIS SHEET. THE INSULATION SHALL MEET MAXIMUM FLAME SPREAD: 25, MAXIMUM FUEL CONTRIBUTED: 50,AND MAXIMUM SMOKE DEVELOPMENT: 50. 4. WATER AND DRAINPIPES AND ANGLE VALVES UNDER LAVATORIES FOR PERSONS WITH DISABILITIES SHALL BE INSULATED PER ADA STANDARD. 5. WATER HEATERS SHALL BE SECURED IN PLACE WITH (2) 26 GA x 1 1/2" SHEET METAL STRAP AROUND THE WATER HEATER. STRAPS SHALL BE INSTALLED ON THE UPPER 1/3 AND LOWER 1/3 OF THE WATER HEATER, AND SECURED AT EACH END BY A #12 SCREW EMBEDDED MINIMUM 1 1/2" INTO SOLID WOOD STUDS (OR MIN. 1" INTO METAL STUDS). THE BOTTOM STRAP SHALL BE LOCATED ABOVE CONTROLS. 6. ALL PLUMBING VENTS SHALL TERMINATE THRU ROOF NOT LESS THAN 121, ABOVE DECK, NOT LESS THAN 10' FROM ANY OUTSIDE AIR INTAKE OR OPENING TO BUILDING, AND NOT LESS THAN T FROM ANT EXTERIOR WALL/PARAPET OF THE BUILDING. 7. BY OTHERS: A. GENERAL CONTRACTOR: ALL ACCESS PANELS, CUTTING, PATCHING, FRAMING, FURRING, PAINTING, AND CONCRETE WORK. B. ELECTRICAL CONTRACTOR: ALL ELECTRICAL SERVICE REQUIRED FOR PLUMBING EQUIPMENT. C. MECHANICAL CONTRACTOR: ALL MECHANICAL EQUIPMENT AND DRAIN PANS. 8. VERTICAL CHECK VALVES SHALL BE SPRING TYPE. HORIZONTAL CHECK VALVE SHALL BE SWING TYPE. 9. ALL FAUCETS ARE TO BE OPERABLE WITH ONE HAND WITHOUT REQUIRING GRASPING OR TWISTING. THE FORCE TO OPERATE SHALL NOT EXCEED 5 LBS, TYPICAL ALL FAUCETS. 10. POTABLE WATER SYSTEMS TO BE DISINFECTED AS REQUIRED BY UPC/SPC AND THE AHJ. 11. SANITARY SEWER WASTE AND LAB WASTE DRAIN LINES TO BE SLOPED AT MINIMUM 1/4" PER V-0". 4" OR GREATER MAY BE SLOPED AT MINIMUM 1/81, PER V-0" WITH APPROVAL FROM THE AHJ. 12. POINT OF CONNECTION TO THE EXISTING PIPING SHALL BE VERIFIED IN THE FIELD. EXACT LOCATION OF POINT CONNECTION MAY VARY BASED ON THE ACTUAL FIELD CONDITIONS. 13. ALL CLEANOUTS TO BE LOCATED AT ACCESSIBLE LOCATIONS. 14. ALL CONDENSATE PIPING TO BE SLOPED AT 1/8" PER V-0" MIN, AND IN FULL COMPLIANCE WITH UPC/SPC . 15. FIXTURES WITH SEPARATE HOT AND COLD SUPPLY HANDLES INCLUDING BUT LIMITED TO 3 COMP SINK, PRE -RINSE SINK, JANITOR SINK, MOP SINK, SHALL HAVE CHECK VALVES INSTALLED IN THE HOT AND COLD WATER SUPPLIES TO PREVENT CROSSOVER. 16. FOR RECYCLED WATER: PROVIDE SIGN PURPLE (PANTONE COLOR #512) BACKGROUND AND SHALL BE IMPRINTED IN NOMINAL 1/2" HIGH, BLACK UPPER CASE LETTERS, WITH THE WORDS "CAUTION: RECYCLED WATER, DO NOT DRINK" IN COMPLIANCE WITH UPC/SPC . AN INITIAL AND SUBSEQUENT ANNUAL CROSS -CONNECTION INSPECTION AND TEST SHALL BE PREFORMED ON BOTH POTABLE AND RECLAIMED WATER SYSTEMS IS REQUIRED PER UPC/SPC . 17. SHOP DRAWING AND ENGINEERING CALCULATIONS FOR ANCHORAGE, SUPPORT, AND SEISMIC BRACING OF MECHANICAL EQUIPMENT, PIPING, ETC. NOT SHOWN ON DRAWING SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE SUBMITTED TO THE AHJ AS A DEFERRED SUBMITTAL PACKAGE. 18. INFRASTRUCTURE NEEDED FOR PIPING AND EQUIPMENT SUPPORT ATTACHMENTS SUCH AS WALL BACKING, DESIGN OF CONCRETE PADS, ETC. SHALL BE INDICATED ON STRUCTURAL DRAWINGS. 5300 DENVER AVENUE SOUTH SEATTLE, WASHINGTON 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BYAND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC. (`ACCO'), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BYACCO IN WRITING. ACCO CANNOTACCEPTANYLIABILITY, WARRANTY, OR OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. EXPIRES: 11-28-2024 1 02/23/2024 PERMIT SET MN No. Date Description By Revisions Project KRUGER BUILDING TENANT IMPROVEMENT 21600 HIGHWAY 99 EDMONDS, WA 98026 Title CONSTRUCTION RECEIVED Feb 26 2024 REQUIREMENTS CILOPMETSERVI DEVELOPMENT SERVICES & EQUIPMENT SCHEDPU"C'Es M.NOYES Designed By M.NOYES Drawn By 60940540 Job Number T.TOUTONGHI Checked By S. ELLIS Project Manager AS NOTED Scale ELEC ROOM 105 STORAGE 105B SCOPE OF WORK ' ELEVATOR 1 Mf H) C, SERVICE 106D 106C EVH (D) C HALLWAY 106A DEMO EXISTING ELECTRIC WATER HEATER REPLACE WITH LIKE -FOR -LIKE. FIELD -VERIFY MFGR OF (D) AND (N) MATCH. EXISTING ELECTRIC WATER HEATER. SCE WITH LIK=-EoR-1 IKE. VERIFY MFG R OF (D) AND (N) MATCH. WORK EqH 1 (D) ELECTRICAL 106E r SUITE 110 VACANT SUITE 100 RAYMOND LIU DDS RR 104 MAIL 104B 1 103 DEMO EXISTING DRINKING FOUNTAIN. MAIN LOBBY 100 SCOPE OF WORK SUITE 120 SWEDISH ADMIN 71C (D) tl SUITE 150 SWEDIS[I EDMONDS WOUND ELEC ROOM 105 'AGE 5B TIE INTO (E) DCW, DHW, T&P RELIEF, & DHWC IF APPLICABLE. SEE P2.01/1 FOR CONNECTION DETAILS. FIELD -VERIFY (E) SCOPE OF WOi PIPE CONFIGURATION & MATCH. F1 FIELD -VERIFY MFGR OF (D) AND (N) MATCH. RE ACE EXISTING ELECTRIC W TER HEATER WITH LIKE -FOR -LIKE. AD (N) EXPANSION TANK IF (E) IS ELEVAT60 SABLE OR MISSING. M H ICAL SERVICE ELECTRICAL 106D 106C 106B E2H I HALLWAY 106A TI I INTO (E) DCW, W, T&P RELIEF, & WC IF APPLICAE LE. SEE P2.01/1 FOR CONNECTION DET I S. FIELD -VERIFY (E) PIPE CONFIGURAT N &MATCH. FI FFD-VERIFY MFG OF (D) AND (N) MATCH. R PLACE EXISTIN ELECTRIC TITER HEATER W D (N) EXPANSIO - - TANK IF (E) IS Sc0 FD . N�ABLE'¢�l, I,S NG. CRAWL CRAWL 1 ACCESS ACCESS P2.o 105D � 105D 1ST FLOOR PLUMBING DEMO PLAN 1 /8"=1 '-0" 115-F TWR ` W DCW — 120'F DHW — — I EXISTING EXPANSION TANK I NIPPLE/UNION T&P TO APPROVED RECEPTOR CONNECT NEW WATER HEATER TO EXISTING DCW, DHW, DHWR, DRAIN, T&P, ETC. HOLDRITE OS-120 SEISMIC RESTRAINT AT )13 AND 3/3 HEIGHT DRAIN PAD R-10 MIN OR STAND, 3" MINIMUM HEIGHT. FIELD VERIFY IF EXISTING. 1" MINA AQUASTAT EXISTING CIRCULATION PUMP PETE'S PLUG (TYP) " DRAIN WITH HOSE CONNECTION (TYP) )Z"BOILER VALVE W/HOSE CONNECTION ELECTRIC WATER HEATER DETAIL EWH 1 (N) I!QFELVAIOR RR Sy 104 �� 0 IMAIL REPLACE (E) DRINKING FOUNTAIN WITH 104B (N) WALL -MOUNTED ADA BI-LEVEL DRINKING FOUNTAIN. DF-1 TO BE MOUNTED FLUSH WITH ALCOVE WALL TO F_ ALLOW FOR ADA CLEARANCES. TIE INTO (E) DCW, SW, & SV SUITE 110 VACANT MAIN LOBBY 100 SCOPE OF WORK SUITE 100 RAYMOND LIU DDS 1ST FLOOR PLUMBING PLAN 1 /8"=1 '-0" 48" x 36" ADA CLEARANCE TO BE CENTERED ON LOW FOUNTAIN. DF 1 (N) T-8" 2'-108" 1, 316„ r O JIT HIGH UNIT DRINKING FOUNTAIN HIGH SIDE TO BE MOUNTED FLUSH WITH ALCOVE WALL TO ALLOW FOR MIN. 36" CLEARANCE CENTERED ON LOW UNIT. INSTALL PER MFR IOM. TIE INTO (E) DCW, SW, SV. FIELD VERIFY ALL PLUMBING UTILITIES. DF-1 ADA CLEARANCE DETAIL �J (N) 2 P2.01 1� SUITE 150 SWEDIS[I EDMONDS WOUND CENTER � I 5300 DENVER AVENUE SOUTH SEATTLE, WASHINGTON 98108 (206) 787-8500 THE PLANS AND SPECIFICATIONS HEREIN ARE OWNED BY AND FOR THE SOLE USE OF ACCO ENGINEERED SYSTEMS, INC. (`ACCO"), AND MAY NOT BE REPRODUCED OR USED BY OTHERS FOR ANY PURPOSE UNLESS AUTHORIZED BYACCO IN WRITING. ACCO CANNOTACCEPTANYLIABILITY, WARRANTY, OR OBLIGATION /N THE EVENT OF UNAUTHORIZED USE. EXPIRES: 11-28-2024 1 02/23/2024 PERMIT SET MN No. Date Description By Revisions Project KRUGER BUILDING TENANT IMPROVEMENT 21600 HIGHWAY 99 EDMONDS, WA 98026 Title R 1ST FLOOR DEMO- CEIVED eb 26 2024 PLUMBING P LA N I DEVCITY ELO MPENT SOERV CES PLUMBING DETAILS DEPARTMENT I M.NOYES 1Designed By M.NOYES Drawn By 60940540 T.TOUTONGHI Checked By S. ELLIS Project Manager AS NOTED IJob Number Scale SCALE: V = 1'4' SCALE: 1" = 1'-0" P2.01