DNS - SUP FILE - FIR2024-0016+Fire_Alarm_Voltage_Calculations+2.21.2024_7.33.49_AM+4071989GENERAL NOTES 1. IT IS THE INTENT THAT THE GENERAL NOTES INDICATED HERE BE APPLICABLE ONLY TO THE CONTRACTED SCOPE OF WORK INDICATED WITHIN THIS DRAWING PACKAGE. NOT ALL NOTES MAY APPLY TO THIS PROJECT. 2. THESE GENERAL NOTES SHALL NOT BE APPLICABLE TO ANY EXISTING CONDITIONS WITHIN THE FACILITY. I.E. EXISTING CONDITIONS FOUND TO BE PRESENT PRIOR TO THIS CONTRACT, WORK PREVIOUSLY PERFORMED BY OTHER FIRE ALARM CONTRACTORS, SEPARATE WORK UNRELATED TO THIS CONTRACT, SYSTEMS PREVIOUSLY APPROVED UNDER PAST CODES / REGULATIONS, ETC. 3. SIEMENS EQUIPMENT IS UNDERWRITERS LABORATORIES (UL) LISTED FOR POWER LIMITED INSTALLATION. 4. ANY RACEWAY RUNS THAT ARE INDICATED WITHIN THIS DRAWING PACKAGE ARE SHOWN DIAGRAMMATICAL AND ARE FOR CIRCUITING PURPOSES ONLY. ALL RUNS SHOWN SHOULD NOT SERVE IN ANY WAY AS AN ACTUAL ROUTING GUIDE FOR INSTALLATION OF RACEWAYS. EXACT INSTALL LOCATION SHALL BE FIELD DETERMINED. 5. A STAMPED SET OF APPROVED FIRE ALARM PLANS SHALL BE ON THE JOB SITE AND USED FOR INSTALLATION. ANY DEVIATION FROM APPROVED PLANS, INCLUDING THE SUBSTITUTION OF DEVICES SHALL BE APPROVED BY THE AUTHORITY HAVING JURISDICTION/ INSPECTOR OF RECORD. SIEMENS SHALL NOT BEAR ANY ADDITIONAL COST FOR RE -ENGINEERING AS A RESULT OF DEVIATIONS. 6. UNLESS OTHERWISE NOTED, ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" ABOVE FINISHED FLOOR TO THE OPERABLE PART. 7. WIRING SHALL NOT BE LOOPED UNDER DEVICE TERMINALS. WIRE MUST BE CUT FOR IN AND OUT RUNS PRIOR TO INSTALLING UNDER DEVICE TERMINALS. 8. ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO USE COLOR CODE AND/OR WIRE NUMBERS PER CONTRACT DOCUMENTATION ON ALL WIRING. SUCH IDENTIFICATIONS SHALL BE MADE CONTINUOUS THROUGHOUT ALL FIRE ALARM CIRCUITS, CONNECTIONS, TERMINATIONS AND AT JUNCTION BOXES. 9. WHERE SHIELDED CABLE IS USED, THE SHIELD SHALL BE CONTINUOUS AND GROUNDED ONLY ONCE AT THE RESPECTIVE CONTROL PANEL. 10. T-TAPPING IS ONLY ACCEPTABLE ON SLC CLASS B CIRCUITS EXCEPT WHERE CONTRACT SPECIFICATIONS PROHIBIT. 11. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. (FIRE ALARM CONTROL PANEL(S) TO SUPERVISE ANNUNCIATOR PANEL(S), SUB-PANEL(S), ALL CIRCUITS AND INITIATING DEVICES). 12. FIRE ALARM SIGNAL SHALL MEET ANSI S3.41, AUDIBLE EMERGENCY EVACUATION SIGNAL (TEMPORAL PATTERN). FIRE ALARM AUDIBILITY SHALL BE NO LESS THAN 15db (PUBLIC MODE) OR 1OdB (PRIVATE MODE) ABOVE AMBIENT SOUND THROUGHOUT THE AREA OF ALARM. 13. WHERE MORE THAN TWO VISUAL APPLIANCES ARE IN THE SAME FIELD OF VIEW, THEY SHALL BE SYNCHRONIZED IN ACCORDANCE WITH NFPA 72. 14. CEILING MOUNTED VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED BELOW VISUAL OBSTRUCTIONS, AND WHEN THESE APPLIANCES ARE MOUNTED ABOVE 10' A.F.F., THEY SHALL BE DERATED OR PROVIDED WITH PERFORMANCE -BASED ALTERNATIVE IN ACCORDANCE WITH NFPA 72. 15. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER INSTALLATION INSTRUCTIONS AND LISTINGS. MISAPPLICATION OF EQUIPMENT AND SUCH, VOIDS ALL WARRANTIES EITHER EXPRESSED OR IMPLIED WITH REGARDS TO LOSS, DAMAGE, LIABILITIES AND/OR SERVICE PROBLEMS. 16. UNLESS NOTED OTHERWISE ALL WIRING AND INSTALLATION METHODS SHALL CONFORM TO APPLICABLE ELECTRICAL CODE. MINIMUM SIZE OF 3/4" METALLIC RACEWAY SHALL BE INSTALLED. 17. EFFORTS MUST BE PLACED ON MINIMIZING UNNECESSARY WIRE RUNS WITHIN DEVICE BACKBOXES. DO NOT INSTALL WIRE WITHIN A BACKBOX THAT DOES NOT SERVE ITS CORRESPONDING DEVICE AND WHICH MAY INHIBIT ITS PROPER INSTALLATION. GOOD WIRING/INSTALLATION PRACTICES MUST BE ADHERED TO AT ALL TIMES. 18. AS FIELD CONDITIONS DICTATE ACTUAL RACEWAY INSTALLATIONS, DEVICE BACK BOXES AND JUNCTION BOXES SHALL BE SIZED PER FIELD INSTALLING CONDITIONS. DEVICE BACK BOX SIZES INDICATED WITHIN THIS DRAWING PACKAGE ARE MINIMUM REQUIREMENTS ONLY. AN INCREASE IN BACK BOX DEPTH, ADDITION OF EXTENSION BOX/RING, ETC. MAY BE REQUIRED IN ORDER TO PROPERLY ACCOMMODATE FOR WIRE QUANTITIES INSTALLED WITHIN THE RACEWAY. 19. THE INSTALLATION OF DEVICE BACKBOXES & WIRE SHALL BE SIZED AND INSTALLED PER APPLICABLE ELECTRICAL CODE. IN ADDITION SUCH BOXES & WIRE SHALL BE INSTALLED IN A MANNER AS TO ALLOW FOR THE EASE OF DEVICE INSTALLATION & FUTURE MAINTENANCE. THE INSTALLATION OF DEVICES WHICH REQUIRE EXCESSIVE FORCE OR THE PINCHING OF WIRES IN ORDER TO PROPERLY SEAT THE DEVICE TO ITS FINISHED SURFACE MAY RESULT IN GROUND FAULTS OR OTHER SYSTEM TROUBLES, AND SHALL BE CONSIDERED AN UNACCEPTABLE INSTALLATION STANDARD. 20. DO NOT APPLY POWER TO CONTROL PANEL(S) UNTIL SIEMENS AUTHORIZED PERSONNEL HAVE VERIFIED THE SYSTEM INSTALLATIONS. UPON SATISFACTORY COMPLETION OF THEIR INSPECTION, POWER WILL BE APPLIED TO THE CONTROL PANEL(S). SIEMENS ASSUMES NO LIABILITY FOR ANY DAMAGE TO THE EQUIPMENT SUPPLIED IF POWER IS APPLIED TO THE CONTROL PANEL(S) PRIOR TO INSPECTION OF THE INSTALLATION BY SIEMENS AUTHORIZED PERSONNEL. 21. ALL 120VAC CIRCUITS FEEDING FIRE ALARM EQUIPMENT SHALL BE FROM A DEDICATED CIRCUIT MARKED AS 'FIRE ALARM', MARKED RED, AND PROVIDED WITH A BREAKER LOCK -ON DEVICE. 22. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 23. IN ACCORDANCE WITH NFPA 72, DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED 24. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES, EXACT ROUTING OF THE CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL THE CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 25. FIRE ALARM CABLE INSTALLED IN UNDERGROUND RACEWAYS OR OTHER WET LOCATIONS SHALL BE RATED/LISTED FOR WET LOCATIONS. (E) CENTRAL MONITORING STATION INFORMATION MONITORING COMPANY: SIEMENS INDUSTRY INC CENTRAL STATION UL NO.# 603961 -026 ADDRESS: 8600 NORTH ROYAL LANE, SUITE 100 CITY / STATE / ZIP CODE: IRVING, TEXAS 75063 TELEPHONE NUMBER: (866) 552-7823 \ (877) 859-4135 FILE NO.: S7091 CCN: UUFX (E) CIRCUIT INFORMATION SIGNALING LINE CIRCUIT (SLC): CLASS B NOTIFICATION APPLIANCE CIRCUITS (NAC): CLASS B PATHWAY SURVIVABILITY: LEVEL 1 SPEAKER CIRCUIT VOLTAGE: 70V SIEMENS CONTACT INFORMATION PROJECT MANAGER: COLIN PINE EMAIL: COLIN.PINE@SIEMENS.COM SALES EXECUTIVE: JOHN MCNETT EMAIL: JOHN.MCNE-FF@SIEMENS.COM CONTRACTOR INFORMATION CONTRACTOR NAME: CHARTER CONSTRUCTION, INC, ADDRESS: 980 S, HARNEY STREET, S EATTLE, WA 98108 APPLICABLE CODES & REGULATIONS STATE OF WASHINGTON ADOPTED CODES -WASHINGTON STATE BUILDING CODE: 2018 EDITION -WASHINGTON STATE FIRE CODE: 2018 EDITION -WASHINGTON STATE MECHANICAL CODE: 2018 EDITION -WASHINGTON STATE ENERGY CODE: 2018 EDITION NATIONAL FIRE PROTECTION ASSOCIATION (NFPA -NFPA 70: 2017 EDITION -NFPA 72: 2016 EDITION CHECK LIST FOR START UP THE FOLLOWING IS A LIST OF CRITERIA THAT MUST BE MEET PRIOR TO START UP ❑ MARK-UP THE SIEMENS FIRE SAFETY SHOP DRAWINGS, SHOWING THE ACTUAL WIRE RUNS. NOTE THAT ANY DISCREPANCIES/CHANGES BETWEEN THE ACTUAL CONDITIONS AND THE SYSTEM DRAWINGS SHOULD BE NOTED FOR INCLUSION ON THE FINAL RECORD DRAWINGS. ❑ ALL DEVICES HAVE BEEN INSTALLED AND TERMINATED PROPERLY. ❑ CONTACTED SIEMENS FIRE SAFETY PROJECT MANAGER 14 DAYS PRIOR TO SCHEDULED START UP. ❑ ALL FIELD DEVICES INCLUDING DETECTORS, MODULES, NOTIFICATION APPLIANCES BOTH VISUAL AND AUDIBLE ARE ADDRESSED AND OUTPUT SET (AS REQUIRED) AND INSTALLED. ❑ IF YOUR SYSTEM IS BEING FURNISHED WITH A DIALER, APPLICABLE AMOUNT OF RJ31 X PHONE JACKS MUST BE INSTALLED WITHIN 3 FEET OF THE MAIN FIRE ALARM CONTROL UNIT. THESE PHONE LINES MUST BE CONNECTED BEFORE ALL BUILDING PHONE EQUIPMENT (NO "9" PREFIX), AND SHOULD HAVE NO DIAL -OUT RESTRICTIONS. PROVIDE THE SIEMENS PROJECT MANAGER WITH A CUSTOMER EMERGENCY CALL LIST. IF MONITORING NOT PROVIDED BY SIEMENS, THEN FOLLOWING INFORMATION MUST ALSO BE OBTAINED PRIOR TO START UP: CENTRAL STATION ACCOUNT NUMBER, RECEIVER PHONE NUMBERS, CENTRAL STATION VOICE LINE NUMBER, AND ALARM COMPANY PHONE NUMBER. ❑ CHECK HERE IF NOT APPLICABLE CHECK FIELD WIRING WITH AN OHM METER: ALL FIRE ALARM CIRCUITS SHOULD BE COMPLETED AND TESTED BEFORE THE ARRIVAL OF THE FIRE ALARM AUTHORIZED PERSONNEL. CIRCUITS MUST BE FREE OF OPENS, SHORTS, AND GROUND FAULTS BEFORE BEING CONNECTED TO THE SYSTEM. CIRCUITS SHOULD HAVE END OF LINE RESISTORS INSTALLED BEFORE TESTING THEM. A WRITTEN CONFIRMATION SHALL BE PROVIDE TO SIEMENS BY THE INSTALLER ACKNOWLEDGING ALL CIRCUITS HAVE BEEN TESTED. ADHERENCE TO THIS PRACTICE WILL SAVE TIME AND MONEY FOR ALL CONCERNED PARTIES. IF IT IS A NAC CIRCUIT, THE RESISTOR IS WITH THE EQUIPMENT THAT CONTROLS THAT CIRCUIT. A GROUND FAULT IS A CONDUCTOR THAT IS CONNECTED TO GROUND. THEY CAN OCCUR FROM SKINNED INSULATION OR INTERNAL DEVICE FAILURES. FIRE ALARM SYSTEMS MONITOR BOTH THE POSITIVE AND NEGATIVE CONDUCTORS FOR SHORTS TO GROUND. SHORTS CAN BE DETECTED BY USING A CONTINUITY DETECTOR OR AN OHMMETER. SIMPLY CONNECT ONE LEAD OF YOUR METER TO A GOOD GROUND SOURCE AND THE OTHER TO THE CONDUCTOR YOU ARE TRYING TO TEST. THE METER SHOULD GIVE AN INDICATION OF AN OPEN IF THE CIRCUIT IF FREE FROM A FAULT. MEG OHM GROUND FAULTS MAY INDICATE THE PRESENCE OF WATER IN CONTACT WITH SYSTEM WIRING. ALL SYSTEM FIELD WIRING MUST BE FREE OF GROUNDS AND SHORTS, BEFORE THE START UP. ❑ MEASURE EACH CONDUCTOR OF THE ADDRESSABLE LOOP (SLC) TO GROUND, CONDUCTOR TO CONDUCTOR, CONDUCTOR TO SHIELD, AND SHIELD TO EARTH. THE RESISTANCE SHOULD BE GREATER THAN 1 MEGA OHM. NOTE LINE TO LINE MEASUREMENTS REQUIRE ONE END OF THE PAIR TO BE SHORTED. STRAY VOLTAGES SHOULD BE LESS THAN 1 VDC/AC. RECORD THE READINGS. ❑ MEASURE EACH CONDUCTOR OF THE NOTIFICATION APPLIANCE CIRCUIT (NAC) TO GROUND, AND CONDUCTOR TO CONDUCTOR. THE RESISTANCE SHOULD BE GREATER THAN 1 MEGA OHM, WITHOUT THE END OF LINE RESISTOR. STRAY VOLTAGES SHOULD BE LESS THAN 1 VDC/AC. ❑ MEASURE ACROSS THE CONDUCTORS OF A NOTIFICATION APPLIANCE CIRCUIT(NAC), YOUR READING SHOULD BE EQUIVALENT TO THE VALUE OF THE END OF LINE RESISTOR INSTALLED AT THE LAST DEVICE. IF THE MEASUREMENTS ARE NOT WITHIN THE ACCEPTABLE VALUES, THEN THE CIRCUIT WIRING HAS A SHORT, OPEN, OR GROUND FAULT, AND IS NOT READY FOR START UP! DEVICE CONDUIT WIRING GUIDELINE INSTALLATION GUIDELINES: DEVICE BACKBOXES SHOULD NOT CONTAIN WIRE THAT DOES NOT SERVE ITS ASSOCIATED DEVICE. TO PREVENT BACKBOX OVERFILL & IMPROPER DEVICE INSTALL, ALL EFFORTS MUST BE MADE TO PREVENT UNNECESSARY WIRE FILL WITHIN DEVICE BACKBOXES. MOUNTING SPECIFICATIONS INDICATED WITHIN THE EQUIPMENT & DEVICE LEGEND ARE MINIMUM RECOMMENDATIONS. JUNCTION BOXES, EXTENSION RINGS, ETC. MUST BE INSTALLED AS NEEDED AND AS FIELD CONDITIONS DICTATE. FLOOR PLAN EXAMPLE: EXAMPLE DEFINED: 1A,4B,2C,1D 1A,4B,2C,1D 1A,4B,2C,1D 1A,46,2C,1D 1A,4B,2C,1D 1A,4B,2C,1D 15CD C 26,2c 2A* p *-WHERE T-TAPPING 15CD C IS ALLOWED, THIS CAN BE1AINCLASS B DEPICTION OF A DIAGRAMMATICAL INSTALL SHOWN ON FLOOR PLAN I ACTUAL FIELD INSTALLATION SLC CIRCUITS DEVICE NUMBERING LEGEND ADDRESSABLE ALARM INITIATING DEVICES EXAMPLE: @S 1-01 DEVICE ADDRESS DEVICE INDICATES DEVICE ADDRESS SYMBOL INDICATES CARD NUMBER ABOVE EXAMPLE MEANS: SMOKE DETECTOR, CARD 1, DEVICE ADDRESS 01 (E) CONDUIT WIRE FILL CHART ELECTRICAL FLEXIBLE METALLIC RIGID METALLIC FLEXIBLE LIQUIDTIGHT METALLIC CONDUIT CONDUIT CONDUIT METALLIC CONDUIT CONDUIT INTERNAL *MAXIMUM INTERNAL *MAXIMUM INTERNAL *MAXIMUM INTERNAL *MAXIMUM TRADE SIZE DIAMETER FILL-40% DIAMETER FILL-40% DIAMETER FILL-40% DIAMETER FILL-40% 3/4" 0.8240 0.2130 0.8240 0.2130 0.8360 0.2200 0.8300 0.2160 1 " 1.0490 0.3460 1.0200 0.3270 1.0630 0.3550 1.0540 0.3490 1 1 /4" 1.3800 0.5980 1.2750 0.5110 1.3940 0.6100 1.3950 0.6110 1 1 /2" 1.6100 0.8140 1.5380 0.7430 1.6240 0.8290 1.5880 0.7920 2" 2.0670 1.3420 2.0400 1.3070 2.0830 1.3630 2.0330 1.2980 * UNIT MEASUREMENTS INDICATED UNDER 40% MAXIMUM FILL REPRESENT SQUARE INCHES. FOR REFERENCE ONLY - RECOMMENDATION FOR CONDUIT SIZE PER N.E.C. SCOPE OF WORK THIS PROJECT IS BEING SUBMITTED AS A TENANT IMPROVEMENT TO THE FACILITIES EXISTING FIRE ALARM SYSTEM. INSTALL DEVICES AS SHOWN IN EQUIPMENT LEGEND AND FLOOR PLANS OF THIS DRAWING PACKAGE. SPLICE, CONTINUE, INSTALL & EXTEND WIRE AS NEEDED TO ENSURE PROPER OPERATING CONDITIONS. IT IS ASSUMED THAT THE FACILITIES EXISTING CONDITIONS (I.E. FIELD DEVICES, REMOTE EQUIPMENT, SEQUENCE OF OPERATIONS, INTERFACE MODULES, ETC.) ARE ALL IN GOOD WORKING CONDITION. ANY EXISTING EQUIPMENT, DEVICES, ETC. THAT MAY BE FOUND TO BE FAULTY SHALL NOT BE REQUIRED TO BE CORRECTED OR REPLACED UNDER THIS CONTRACT. UPON COMPLETION A COMPLETE PRETEST SHALL BE PERFORMED TO VERIFY FUNCTIONALITY. IF THE FUNCTIONALITY IS COMPLETE THEN THE PROPER DOCUMENTATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION PRIOR TO SCHEDULING A FINAL INSPECTION. THIS PROJECT INCLUDES THE FOLLOWING: TO BE ADDED- 09 CONTROL RELAY MODULES FOR WANDER DOOR INTERFACE Zj� DEVICE INSTALLATIONIOPERATING GUIDELINES Zt 100°= THE UL LISTED OPERATING TEMPERATURE RANGE FOR ALL ADDRESSABLE DEVICES IS FROM 327 (0°C) TO 100°F (38°C). IF A DEVICE IS SHOWN IN AN AREA WHICH MAY 32 = EXPERIENCE EXTREME COLD OR HEAT, CONTACT YOUR SIEMENS REPRESENTATIVE. FIRE ALARM EQUIPMENT SHALL NOT BE STORED OR INSTALLED IN AREAS EXPOSED TO THE ELEMENTS EXCEEDING NORMAL OPERATING CONDITIONS. LISTED WEATHERPROOF DEVICES MAY BE INSTALLED AT EXTERIOR LOCATIONS PER MANUFACTURER ' INSTRUCTIONS. ALL OTHER DEVICES NOT SPECIFICALLY LISTED AS WEATHERPROOF MUST BE INSTALLED IN SUITABLE LOCATIONS OR LISTED NEMA ENCLOSURES APPLICABLE FOR THE ANTICIPATED ENVIRONMENT AND DEVICES TO BE INSTALLED. THE INSTALLATION OF A FIRE ALARM SYSTEM AND ANY FIRE ALARM EQUIPMENT MUST NOT BE INSTALLED NEXT TO OR WITHIN CLOSE PROXIMITY OF ANY RADIO FREQUENCY EQUIPMENT (EMI, RF, MF, HIGH OUTPUT, ETC.). SUCH INSTALLING CONDITIONS MAY RF EMI CAUSE UNDESIRABLE EFFECTS TO THE SYSTEM SUCH AS INTERMITTENT FAULTS, IMPROPER SYSTEM OPERATIONS, FALSE ALARMS, ETC. ENSURE EACH ADDRESSABLE DEVICE HAS BEEN PROPERLY PROGRAMMED PRIOR TO ITS INSTALLATION. DO NOT TERMINATE WIRES ONTO ADDRESSABLE DEVICES BEFORE IT HAS a BEEN PROGRAMMED. DPU DO NOT REMOVE DUST COVERS FROM SMOKE DETECTORS UNTIL ALL CONSTRUCTION HAS BEEN COMPLETED. DUST COVERS WHICH HAVE BEEN REMOVED FROM ANY DETECTOR PRIOR TO THE FINAL CLEAN-UP OF ALL TRADES SHALL BE CLEANED OR REPLACED, IN ACCORDANCE WITH NFPA 72. SIEMENS IS NOT RESPONSIBLE FOR FAULTS FOUND TO BE RELATED TO CONTAMINATION. E I ALL INITIATING DEVICES (DETECTORS, PULL STATIONS, ETC.) AND NOTIFICATION APPLIANCES (HORNS, STROBES, ETC.) MUST BE INSTALLED WITH BACKBOXES. THE EQUIPMENT SHOULD NEVER BE SUPPORTED WITH THE CIRCUIT WIRES. THE USE OF MAGNETS FOR THE PURPOSE OF TESTING DETECTORS FOR INITIATION OF - AN ALARM IS STRICTLY PROHIBITED. TESTING WITH A MAGNET DOES NOT SATISFY NFPA 72 TEST METHOD REQUIREMENT OF 'SMOKE ENTRY INTO THE SENSING CHAMBER', AND MAY CAUSE UNDESIRABLE EFFECTS TO THE DETECTOR. THE PAINTING OR MODIFYING OF ANY FIRE ALARM EQUIPMENT IS STRICTLY PROHIBITED AND SHOULD NOT BE PERFORMED UNDER ANY CIRCUMSTANCES. (E) CABLE LEGEND CABLE TYPE DRY LOCATION CIRCUIT DESIGNATION WET LOCATION DESCRIPTION OPEN CABLE IN CONDUIT 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR 2-COND #16 TWISTED PAIR SOLID FPL* CABLE SOLID FPL* CABLE FPL CABLE (SLC) LOOP D WEST PENN #AQ225 OR EQUIVALENT ADDRESSABLE RED JACKET -RED BLACK RED JACKET -RED BLACK RED JACKET -RED BLACK THE ABOVE REFERENCED IS THE RECOMMENDED WIRE TYPE TO BE UTILIZED. WIRE SUBSTITUTIONS OF A SIMILAR TYPE AND OF A LIKE NATURE MAY BE UTILIZED. THE USE OF ALTERNATE WIRE TYPES MUST BE ACCEPTED BY THE AHJ AND MEET THE SAME CRITERIA, SPECIFICATIONS, LISTINGS, ETC. AS THE ABOVE WIRE INDICATED. * - PROPER USE OF LISTED FPL/FPLR/FPLP CABLE SHALL BE USED IN APPLICABLE INSTALLATION PER ELECTRICAL CODE. THIS PROJECT TO BE INSTALLED AS A CONDUIT INSTALLATION. PROVIDE REQUIRED SUPPORTS SPACED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE. PROVIDE CONDUIT OR OTHER RACEWAY WHERE REQUIRED BY CODE FOR PROTECTION OF WIRING/CIRCUITS. WHERE CONDUIT IS USED, SIZE ACCORDINGLY TO THE CONDUIT FILL CHART AND APPLICABLE ELECTRICAL CODE. EXAMPLE: NUMBER OF CONDUCTOR PAIRS WIRE TYPE DESIGNATION METALLIC RACEWAY/OPEN CABLE/PLENUM CABLE/ETC. (WHERE APPLICABLE) ,MEANS ABOVE EXAMPLE "2A" "2 TWISTED PAIR CABLES" ALL WIRE AND CABLE TO BE SIGNED, TYPED AND CONDUIT FILL PER ELECTRICAL CODE AND MANUFACTURER'S RECOMMENDATION. BUILDING/PROJECT INFORMATION BUILDING OCCUPANCY: A/B/R-1/R-2/S SPRINKLERS: YES CONSTRUCTION TYPE: TYPE 1 A NUMBER OF STORIES: 1 GARAGE + 3 FLOORS SHEET INDEX SHEET NUMBER SHEET TITLE FAO. 01 SYSTEM INFORMATION & NOTES FAO.02 EQUIPMENT LIST, SEQUENCE OF OPERATIONS, WIRING DETAILS & CABCS FA1.10 FIRST LEVEL FIRE ALARM PLAN FA1.20 SECOND LEVEL FIRE ALARM PLAN FA1.30 THIRD LEVEL FIRE ALARM PLAN FA2.01 SYSTEM RISER DIAGRAM TYPICAL CALLOUTS & ABBREVIATIONS AC = ABOVE CEILING HT = HEIGHT AFF = ABOVE FINISHED FLOOR ID = IN -DUCT MOUNTED AHJ = AUTHORITY HAVING JURISDICTION IDC = INITIATING DEVICE CIRCUIT AHU = AIR HANDLING UNIT MAX = MAXIMUM ANN = ANNUNCIATOR MIN = MINIMUM BMS = BUILDING MANAGEMENT SYSTEM N = NEW C = CEILING MOUNTED N/A = NOT APPLICABLE "C = CONDUIT (CIRCULAR RACEWAY) NAC = NOTIFICATION APPLIANCE CIRCUIT CD = (i.e., 15CD) CANDELA NIC = NOT IN CONTRACT CFM = CUBIC FEET PER MINUTE (AIRFLOW) NTS = NOT TO SCALE CKT = CIRCUIT PS = POWER SUPPLY CSFD = COMBINATION SMOKE FIRE DAMPER RA = RETURN -AIR GRILL MOUNTED DACT = DIGITAL ALARM COMM. TRANSMITTER RL = RELOCATED DEVICE DR = DROP & RE -HANG EXISTING RR = REMOVE EXISTING, REPLACE w/ NEW E = EXISTING SF = DEVICE MOUNTED IN SUB -FLOOR EL = ELEVATOR RECALL SLC = SIGNALING LINE CIRCUIT EOL = END OF LINE TBD = TO BE DETERMINED EOLP = END OF LINE POWER MODULE TYP = TYPICAL EPO = EMERGENCY POWER OFF OF = UNDER -FLOOR ER = EXISTING TO BE RELOCATED UON = UNLESS OTHERWISE NOTED FAA = FIRE ALARM ANNUNCIATOR WM = DEVICE WALL MOUNTED FACP = FIRE ALARM CONTROL PANEL WP = WEATHERPROOF FACU = FIRE ALARM CONTROL UNIT X = DEMO EXISTING FATC = FIRE ALARM TERMINAL CABINET XP = EXPLOSION PROOF FBO = FURNISHED BY OTHERS EX = EXISTING DEVICE FSD = FIRE SMOKE DAMPER VL = VERIFY LOCATION IN FIELD (E) WIRING GUIDELINES PLENUM CABLE VS. NON -PLENUM THE NEC RECOGNIZES 3 TYPES OF POWER LIMITED FIRE ALARM CABLING: FPL - THIS IS A GENERAL USE POWER LIMITED FIRE ALARM CABLE. IT CANNOT BE USED IN A PLENUM SPACE OR FOR RISERS (CABLING BETWEEN FLOORS), CABLE MUST BE IN CONDUIT. FPLR - THIS IS A POWER LIMITED RISER RATED CABLE THAT CAN BE USED FOR GENERAL PURPOSES OR BETWEEN FLOORS. IT CANNOT BE USED IN A PLENUM SPACE, CABLE MUST BE IN CONDUIT. FPLP - THIS IS A POWER LIMITED CABLE THAT CAN BE USED IN A PLENUM, RISER, OR FOR GENERAL PURPOSE. A PLENUM IS ANY AREA USED TO CONDUCT ENVIRONMENTAL AIR. PLENUM SPACES CAN BE DUCTWORK, THE SPACE ABOVE A DROP CEILING, OR BELOW A RAISED FLOOR. BECAUSE THESE SPACES ARE BEING USED FOR THE AIR HANDLING SYSTEM. THERE ARE STRICT RULES THAT MUST BE FOLLOWED TO REDUCE THE RISK OF INTRODUCING TOXIC FUMES IN THE EVENT OF A FIRE. SINCE FIRE ALARM CABLING IS OFTEN INSTALLED EXPOSED, WITHOUT CONDUIT, ABOVE DROP CEILINGS THE CABLING MUST BE RATED FOR USE IN A PLENUM SPACE. (E) WIRING REQUIREMENTS • THE DRAIN SHIELD IS A VERY IMPORTANT PART OF THE SYSTEM INSTALLATION. SHIELDED WOULD NOT SPECIFY SHIELDED CABLE IF IT WAS NOT NECESSARY. SHIELDS SHOULD BE KEPT CONTINUOUS THROUGHOUT THE CIRCUIT AND KEPT FREE FROM ANY REFERENCE TO EARTH GROUND. • SHIELDED CABLE CAN BE FPL, FPLR, OR FPLP. NETWORK COMMUNICATIONS BETWEEN FIRE ALARM CONTROL PANELS AND REMOTE ANNUNCIATORS REQUIRE SHIELDED CABLE. • INTELLIGENT ADDRESSABLE INITIATING DEVICES REQUIRE NON -SHIELDED CABLE. • NOTIFICATION APPLIANCES (I.E. - HORN/STROBES, HORNS, ETC.) REQUIRE NON -SHIELDED CABLE. • UNDERGROUND CABLE, WHETHER OR NOT INSTALLED IN CONDUIT, SHALL BE LISTED AS UNDERGROUND BURIAL TYPE. • WIRING IS TO BE INSTALLED POINT TO POINT WITH NO SPLICING. VICINITY MAP NORTH SCOPE OF WORK: CHARTER CONSTRUCTION SUNRISE FA T.I. 0 SUNRISE OF EDMONDS, 1 750 EDMONDS WAY, I EDMONDS, WA 98020. 1 I5th St SW r j=5th St `'w ; co 26th St SNf 226th St SW g 15th StSW 15th St SW o rn Q 1 r s Edmonds -Westgate I 1~ a n Veterinary Hospital PS :E I PI SW 226th pf s ✓ 2261tt � _ 1 0 n Edmo I ds Memorial Cemetery 5,a Rosewood CourteQ �a 1 0 IIN m 22711, PI SV Sunrise o t 228111 St SVi aQ oyo Edmonds Goodwill Thrift store r 0 QAmanda AHPhoto n Pagliacci Pizza Anytime Fitness Pizza -3z Edmonds L Hattrup & Associates PS o t QFC® ` 19th PI SW MaC2 ro -T19 Fast Food • Y IN T rr,.i.,o ui,1. no.,tim,.,0 O APPROVAL STAMPS SIEMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the some be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHN ITREJ AN NICET LEVEL: IV DATE SIG ED. 02/19/2024 FIRE ALARM SYSTEMS CONTROL LOG: 2024-015 CERT: 104316 AGENCY REFERENCE: 00 02/15/24 ISSUED FOR PERMIT APK REV DATE REMARKS INTL NO. 1 DRAWN: APK 1 CHECKED: G N SHEEP DESCRIPTION - FIRE ALARM SYSTEM SYSTEM INFORMATION & NOTES JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. DRAWING NUMBER: FA0m01 SHEET SIZE: ARCH E1 - 3002 NEW EQUIPMENT LIST ALL PARTS ARE SIEMENS UNLESS OTHERWISE NOTED INITIATING DEVICES SYMBOL QTY MODEL/PART NUMBER DESCRIPTION ROUGH IN FACP (E) DESIGO MODULAR DESIGO FIRE SAFETY MODULAR FIRE ALARM CONTROL UNIT SEMI -FLUSH OR SURFACE MOUNT ER MI 09(N) 54370-B1-A1 INTELLIGENT CONTROLLABLE RELAY w/ SINGLE INPUT MONITOR MODULE 4S DEEP BOX EXISTING EQUIPMENT LIST FACU COMPONENTS SYMBOL QTY MODEL NUMBER DESCRIPTION ALL PARTS ARE SIEMENS UNLESS OTHERWISE NOTED ROUGH IN FACP (E) CAB3-BB 500-633011 THREE ROW CABINET BACKBOX --- (E) CAB3-BD 500-633010 THREE ROW CABINET INNER AND OUTER DOOR SET --- (E) OD -LP 500-633016 OUTER DOOR ROW LENS PLATE INTERNAL PANEL COMPONENT (E) OD -BP 500-633017 OUTER DOOR ROW BLANK PLATE INTERNAL PANEL COMPONENT (E)OD-GP 500-633018 OUTER DOOR ROW VENTED GRILL PLATE INTERNAL PANEL COMPONENT (E) XDACT-ASSY S54430-A5-A1 DIGITAL ALARM COMMUNICATION TRANSMITTER ASSEMBLY FOR XLS INTERNAL PANEL COMPONENT (E) FCA2015-U1 S54400-A63-A1 DIGITAL ALARM COMMUNICATION TRANSMITTER FOR XLS INTERNAL PANEL COMPONENT (E) ZAM-180 500-035600 ZONE AMPLIFIER MODULE (180 WATTS) INTERNAL PANEL COMPONENT (E) CC-5 500-633037 5-SLOT CARD CAGE INTERNAL PANEL COMPONENT (E) ZIC-4A 500-033050 4 CIRCUIT ZONE INDICATING CARD INTERNAL PANEL COMPONENT (E) ZIC-86 500-648670 8-CIRCUIT ZONE INDICATING CARD INTERNAL PANEL COMPONENT (E) NIC-C 500-033240 NETWORK INTERFACE CARD INTERNAL PANEL COMPONENT (E) PSC-12 500-033340 POWER SUPPLY WITH BATTERY CHARGER (INCLUDES PTB TERMINATION BOARD) INTERNAL PANEL COMPONENT (E) PSX-12 500-034120 POWER SUPPLY EXTENDER INTERNAL PANEL COMPONENT (E) PTB 500-033390 POWER TERMINATION BOARD INTERNAL PANEL COMPONENT (E) DAC-NET 500-035100 DIGITAL AUDIO CARD D-NET INTERNAL PANEL COMPONENT (E) XDLC S54430-68-A1 DEVICE LOOP CARD (COMPATIBLE w/ ISOLATION DEVICES) INTERNAL PANEL COMPONENT (E) CAB-BATT 500-633917 BATTERY CABINET FOR UP TO (2) 100 A.H. BATTERIES SURFACE OR SEMI -FLUSH MOUNT (E) PS-121000 �A730026435 BATTERY 12 VOLT 100 AMP HOUR (SET) BATTERY CABINET ALL ARE SIEMENS ANNUNCIATOR COMPONENTS UNLESSRTS OTHERWISE NOTED SYMBOL QTY MODEL NUMBER DESCRIPTION ROUGH IN FAA (E) SSD-C REMOTE ANNUNCIATOR PANEL 4S DEEP BOX REMOTE POWER SUPPLY PANEL COMPONENTS UALL PATS ARE SIEMENS NLESSROTHERWISE NOTED SYMBOL QTY MODEL NUMBER DESCRIPTION ROUGH IN 12 24 (E) PS-12/24-8 FIRE ALARM POWER SUPPLY SURFACE MOUNT ALL ARE SIEMENS INITIATING DEVICES UNLESSRTS OTHERWISE NOTED SYMBOL QTY MODEL NUMBER DESCRIPTION ROUGH IN O OS A (E) FDOT421 S5432046-A1 INTELLIGENT PHOTOELECTRIC SMOKE DETECTOR HEAD DB-11 FE) DB-11 500-094151 DETECTOR BASE 4S DEEP BOX w/ 1-GANG RING 0 (E) FDT421 S54320-F5-A1 INTELLIGENT HEAT DETECTOR HEAD DB-11 (E) DB-11 500-094151 DETECTOR BASE 4S DEEP BOX w/ 1-GANG RING ❑F (E) HMS-S 500-033200 INTELLIGENT MANUAL PULL STATION DUAL ACTION 4S DEEP BOX w/ 1-GANG RING TRI-R (E) XTRI-R S54370-B1-A1 INTELLIGENT CONTROLLABLE RELAY w/ SINGLE INPUT MONITOR MODULE 4S DEEP BOX TRI-S (E) XTRI-S S54370-B3-A1 INTELLIGENT SINGLE INPUT MONITOR MODULE 4S DEEP BOX TRI-D (E) XTRI-D S54370-B2-A1 INTELLIGENT DUAL INPUT MONITOR MODULE 4S DEEP BOX ICP (E) HCP 500-034860 INTELLIGENT CONTROL POINT MODULE 4S DEEP BOX NOTIFICATION DEVICES ALPARSARE SIEMENS UNLESSOTHERWISE NOTED SYMBOL QTY MODEL NUMBER DESCRIPTION ROUGH IN Lr N 15 30 175 10 (E) E70-24MCW MULTI -CANDELA SPEAKER/NON-LED STROBE, 25/70V, WALL MOUNT -WHITE FIELD SELECTABLE 15/30/75/110cd, 1/8-2W 4S DEEP BOX w/ 1-GANG RING F 15 75 110 (E) RSS-24MCW MULTI -CANDELA NON -LED STROBE, WALL MOUNT - WHITE FIELD SELECTABLE 15/30/75/110cd 4S DEEP BOX w/ EXTENSION (E) E70 FIELD KSEL CTABOLE 1�g I8W MOUNT -RED EXTENSION4S DEEP BOX w/ ALL ARE SIEMENS MISCELLANEOUS DEVICES UNLESSRTS OTHERWISE NOTED - ----- END OF LINE RESISTOR F.B.O. ® - F.B.O. FOREIGN SYSTEM INTERFACE F.B.O. �M - DHF-1224C FIRE ALARM DOOR F.B.O. O� SINGLE INPUT RELAY MODULE WIRING DIAGRAM NOT TO SCALE -- SEE THE INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION SLC WIRING SHOWN FOR POLARITY INSENSITIVE USAGE. FOR ISOLATOR MODE SEE BELOW. FROM + + PREVIOUS DEVICE _ _ _ TO NEXT DEVICE OR FACP - i Q13 A, O - - - R _ TO CONTROLLED DEVICE XTRI-R' (NO/NC CONTACTS AS - APPLICABLE) RELAY MUST BE MOUNTED SUPERVISED I WITHIN 3 FEET OF SWITCH* CONTROLLED DEVICE EOL Xnf-R MAY OONTACr RUNGS APFRAGE VOLTAGE TYPE ,A 12N. FENNE IA 3M& RESISRYE EEE4 3SA 12Wx MUCINE 0.6 PF O AA IOA 3W& iii5 N U PF SLC WIRING FOR ISOLATOR MODE USAGE - UP TO 30 DEVICES IN POLARITY INSENSITIVE MODE WITH UP TO 200 LINE RESISTANCE MAY BE CONNECTED BETWEEN TWO DEVICES IN ISOLATOR MODE. MAX 190 DEVICES IN ISOLATOR MODE PER XDLC. FROM PREVIOUS DEVICE TO NEXT DEVICE OR FACP z O a U � Z w W `Rn C Y N a o g9N E a��yo o< U CJ 9k � O=OwZw CD C-, z Z Z2pwc CD C-, = �Z� m�0 0�� � lr'ry'A , W. � r N W ME a U wCjfoz CD owoc x U_ wWN=vNi wocLi *CAN BE CONFIGURED TO MONITOR N/O OR N/C CONTACTS. VERIFY APPLICATION WITH FIELD PERSONNEL. lj� (n rl w rL o a_ ACV Ii 4i16 MODEL DESCRIPTION IMOUNTING CONFIGURATION (SEE SYMBOLS LEGEND FOR REQ'S) XTRI-R SINGLE INPUT RELAY MODULE 4" SQUARE �2 I WANDER DOOR CONTROL WIRING DIAGRAM G NOT TO SCALE -- SEE APPLICABLE DEVICE INSTRUCTIONS FOR ADDITIONAL INFORMATION FIRE ALARM RELAY (NO/NC CONTACTS AS APPLICABLE) - }FIRE INTERFACE CONTROL \\-WANDER DOOR CONTROLLER (BY OTHERS) �3 I FIRESTOP DETAIL - GYPSUM STUD WALL NOT TO SCALE -- SEE APPLICABLE EQUIPMENT INSTRUCTIONS FOR ADDITIONAL INFORMATION System No. W-L-1001 F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - Less Than 1 CFM/sq ft 114-00-1111 LA 16 SECTION A -A 1. Wall Assembly - The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs - Wall framing may consist of either wood studs (max 2 hr fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (610 mm) OC. B. Gypsum Board* - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in. (660 mm). 2. Through Penetrant - Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in. (0 mm) (point contact) to max 2 in. (51 mm). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 24 in. (610 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. pipe, nom 12 in. (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing. D. Copper Tubing - Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. F. Through Penetrating Product* - Flexible Metal Piping - The following types of steel flexible metal gas piping may be used: 1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. OMEGA FLEX INC 2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. GASTITE, DIV OF TITLEFLEX 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG LLC 3. Fill,Void or Cavity Material* - Caulk or Sealant - Min 5/8. 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and 64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: Max Pipe or Conduit Diam in. (mm) F Rating Hr T Rating Hr 1 (25) 1 or 2 0+, 1 or 2 1 (25) 3 or 4 3 or 4 4 (102) 1 or 2 0 6 (152) 3 or 4 0 12 (305) 1 or 2 0 +When copper pipe is used, T Rating is 0 hr. 3M COMPANY - CP 25WB+ caulk or FB-3000 WT sealant, *Bearing the UL Classification Marking (E) SEQUENCE OF OPERATIONS Control Unit Building Sequence of Operations Notification Required Fire Safety Control Annunciation AUDIBLE MESSAGE TO BE (FEMALE VOICE, ENGLISH) - "May I have your attention please, may I have your attention please? There has 00 0 been a fire emergency reported in the building. _ o o N o 4.1 (n 0 o Please evacuate the building by the nearest o c� J N O Cn 00 U v 0' N exit, do not use the elevators." J N -a L o 0 0 0 C N (n (D - � N M L U O }, }' C 0 0) �. N 0 N a) Z Z O ^�' 4- (73 2 N a) N 0 O } N U) O >✓ C O O N N O E ,✓ a) � 0 O O 0 70 >_ N o : c U N N a M iL, o C C L �' Q ° (73 L °' X 70 * - Elevator recall to primary or alternate floor and P Y � w J � M v, o Ta E o o M M 0 E .-. - .-. o m m Visual Warning (Firefighter Hat) shall be M U 0 to ^ (n 0 - �4_1_ �_ L L o o performed by the elevator controller per the Q j O 4- cc o T E N L E N 0 0 Elevator Code ASME A17.1 ¢ � I-- a) � 0 O 0 cn � N � 0 Q M 0 N N= � a a L 0 0 0 0 0 O E O C) O w O J N E p �� a) a) a) L a) O > 0,�6( W > (u_ 0�6X U W � � � (D O >, N � O � > U > U O O O N }' - IY -0 w e a D-0 O -0 _0 n L M 0- �+ 2 O o U �/ M o � M� 0 0 a) W N _ _� U� a) c� a) c� CL N� 0 .O L 0 0 C 0 C o M (D a� aJ � Q-1 a� � cn Q a_ Ii f � Q -_ a) V) ch cn (n cn (� a) (n Z a) -0 - }. U O U 0 O - > > m a) W U U U M U a-1 L E a-1 L E a--+ L � _ �_ � � � � a) O � (D � � ( L N (D4_1 N .> � O N _r N (73 (n (>3 T a) 0 O - N a) cQ c>3 ca O O N O c>3 >, to ca c� O c� c� a... > System Inputs Q Q Q r_ Q L � � L � � L � � U (D Q 0 Z U a) Q ~ U Q U O Q U U Q U M ¢ co W O T_ � W Iz W Of CO a] C� U Q > Manual fire alarm box X X X X X X X X Smoke detector above FA panel X X X X X X X X Smoke detector @ door hold location X X X X X X X X Area smoke / heat detector X X X X X X X X Top of stair smoke detector X X X X X X X X Patient room smoke detector / heat detector X X X X X X X X X X X Residential unit smoke sensor X X X X Residential ADA unit smoke sensor X X X X X Elevator lobby smoke detector -main floor X X X X X X X X X X Elevator lobby smoke detector -all other floors X X X X X X X X X X Elevator machine room @ main floor smoke det X X X X X X X X X X X Elevator machine room heat detector X X X X X X X X X Elevator hoistway smoke detector X X X X X X X X X X X Elevator hoistway heat detector X X X X X X X X X Elevator120VAC shunt trip circuit failure X X X Sprinkler water flow switch X X X X X X X X Sprinkler valve supervisory switches X X X Ansul or HOOD system activation X X X X X X X X FACU 120VAC power failure X X X X X Remote power supply trouble (power, wiring) X X X System device trouble X X X System wiring trouble (ground, open, short) X X X SEQUENCE OF OPERATIONS TO MATCH THE EXISTING BUILDING SEQUENCE OF OPERATIONS (E) FIRE ALARM CONTROL PANEL BATTERY CALCULATION BUILDING NAME: SUNRISE SENIOR LIVING PANEL NAME: FACP PANEL LOCATION: ELEC. 04 Qty Model Description Standby Current (mA) Alarm Current (mA) Per Device Current Total Current 6.2V Backplane Current 6.2V to 24V equivalent current 24V Backplane Current 24V Screw Terminal Current Per Device Current Total Current A B (Qty*A) C D (C*6.2/24) E F G (D+E+F) H (Qty*G) 1 FCM2041-U2 Desigo Modular Operator Interface 125 125 195 195 195 1 PSC-12 Power Supply/Battery Charger 150 150 150 150 150 4 Active Relays 20 80 20 20 80 1 PSX-12 Power Supply Extender 150 150 150 150 150 1 DAC-NET Digital Audio Card with Network 230 230 230 230 230 1 NIC-C Network Interface Card 120 120 120 120 120 1 XDMC Digital Message Card 170 170 140 36.17 140 176.17 176.17 1 ZAM-180 Zone Amplifier Module 180 Watts 300 300 300 300 300 180 Speaker Load Watts 0 0 51.11 51.11 9199.8 1 ZAM-180 (Backup) Zone Amplifier Module 180 Watts 300 300 0 0 1 ZIC-4A Zone Indicating Card 89 89 89 89 89 4 Active Speaker Circuits 0 0 34 34 136 1 ZIC-8B Zone Indicating Card 105 105 0 0 8 Active Circuits 0 0 17 17 136 4 XDLC Class X Device Loop Card 100 400 1 0.26 100 100.26 401.04 208 FDOT421 Photo -thermal detector 0.25 52 0.41 0.41 85.28 3 FDT421 Thermal detector 0.25 0.75 0.41 0.41 1.23 8 HCP Addressable control point 1 8 1 1 8 11 HMS-S Manual station 0.9 9.9 0.9 0.9 9.9 10 XTRI-D X Dual input module 0.5 5 0.95 0.95 9.5 19 XTRI-R X Single input/single relay module 0.5 9.5 1 0.75 0.75 14.25 1 XTRI-S Ix Single input module 0.5 0.5 0.65 0.65 0.65 1 FCA2015-U1 IDigitalAlarm Communicator Transmitter 33.5 33.5 43.5 143.5 143.5 Total Standby Current: 2.3381 Amps Total Alarm Current: 11.5353 Amps BATTERY SIZING CALCULATIONS: Total Standby Current: 2.3381 Amps Standby Time Required: 24 Hours Total Alarm Current: 11.5353 Amps Alarm Time Required: 15 Minutes Total Standby Current x Standby Time: 56.1144 Ah Battery Size Provided: 100 Ah Total Alarm Current x Alarm Time: 2.8838 Ah Calculated Minimum Battery: 73.75 Ah Total LOAD (Total Standby Ah + Total Alarm Ah): 58.9982 Ah Spare Battery Capacity: 26.25 Ah Min. Battery Size (Total LOAD x 1.25 Safety Factor): 73.7478 Ah 120VAC Current: 7 Amps APPROVAL STAMPS SIEMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the some be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHNZ ITREJ AN NICET LEVEL: IV DATE SIG 02/19/2024 FIRE ALARM SYSTEMS CONTROL LOG: 2024-015 CERT: 104316 AGENCY REFERENCE: 00 02/15/24 JISSUED FOR PERMIT I APK REV DATE REMARKS INTL NO. 1 DRAWN: APK 1 CHECKED: G N SHEET DESCRIPTION: FIRE ALARM SYSTEM EQUIPMENT LIST, SEQUENCE OF OPERATIONS, WIRING DETAILS & CALCS JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. DRAWING NUMBER: FAOmO2 SHEET SIZE: ARCH E1 - 3002 APPROVAL STAMPS DRAWING NOTE: LALLEVICES OUTSIDE AREA OF WORK SHALL BE CONSIDERED AS EXISTING TO REMAIN. DRAWING NOTE: ALL DEVICES NOT INDICATED WITH AN ASSOCIATED CALLOUT SHALL BE CONSIDERED AS EXISTING TO REMAIN. NOTES ABBREVIATIONS: (E) EXISTING DEVICES (N) NEW DEVICES N.I.C. NOT IN CONTRACT GENERAL NOTES: 1. CONTROL RELAY MODULES SHALL BE MOUNTED WITHIN 3FT FROM THE CONTROLLERS. KEY NOTES: 0 1. 24 VDC POWER SUPPLY FOR ALL WANDER DOORS SHALL BE PROVIDED BY OTHERS. SIEMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the same be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHN MAITREJ DATE SIG9ED: 02/19/2024 - CONTROL LOG: 2024-015 AGENCY REFERENCE: NICET LEVEL: IV FIRE ALARM SYSTEMS CERT: 104316 1 00 02/15/24 JISSUED FOR PERMIT APK N0. REV DATE REMARKS INTL DRAWN: AP K CHECKED: G N SHEET DESCRIPTION: FIRE ALARM SYSTEM FIRST LEVEL FIRE ALARM PLAN JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. NORTH FIRST LEVEL FIRE ALARM PLAN SCALE: 1/8 11 = 1 9_091 0 4' 8' 16' 0 DRAWING NUMBER: FAI ■ l 0 SHEET SIZE: ARCH E1 - 3002 DRAWING NOTE: ALL DEVICES OUTSIDE AREA OF WORK SHALL BE CONSIDERED AS EXISTING TO REMAIN. APPROVAL STAMPS DRAWING NOTE: ALL DEVICES NOT INDICATED WITH AN ASSOCIATED CALLOUT SHALL BE CONSIDERED AS EXISTING TO REMAIN. NOTES ABBREVIATIONS: (E) EXISTING DEVICES (N) NEW DEVICES N.I.C. NOT IN CONTRACT GENERAL NOTES: 1. CONTROL RELAY MODULES SHALL BE MOUNTED WITHIN 3FT FROM THE CONTROLLERS. KEY NOTES: 0 1. 24 VDC POWER SUPPLY FOR ALL WANDER DOORS SHALL BE PROVIDED BY OTHERS. SIEMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the same be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHN MAITREJ DATE SIG9ED: 02/19/2024 - CONTROL LOG: 2024-015 AGENCY REFERENCE: NICET LEVEL: IV FIRE ALARM SYSTEMS CERT: 104316 1 00 02/15/24 JISSUED FOR PERMIT APK N0. REV DATE REMARKS INTL DRAWN: AP K CHECKED: G N SHEET DESCRIPTION: FIRE ALARM SYSTEM SECOND LEVEL FIRE ALARM PLAN JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. NORTH SECOND LEVEL FIRE ALARM PLAN SCALE: 1/8 11 = 1 9_011 0 4' 8' 16' 0 DRAWING NUMBER: FAI ■ 2 O SHEET SIZE: ARCH E1 - 3002 DRAWING NOTE: ALL DEVICES OUTSIDE AREA OF WORK SHALL BE CONSIDERED AS EXISTING TO REMAIN. APPROVAL STAMPS DRAWING NOTE: ALL DEVICES NOT INDICATED WITH AN ASSOCIATED CALLOUT SHALL BE CONSIDERED AS EXISTING TO REMAIN. NOTES ABBREVIATIONS: (E) EXISTING DEVICES (N) NEW DEVICES N.I.C. NOT IN CONTRACT GENERAL NOTES: 1. CONTROL RELAY MODULES SHALL BE MOUNTED WITHIN 3FT FROM THE CONTROLLERS. KEY NOTES: 0 1. 24 VDC POWER SUPPLY FOR ALL WANDER DOORS SHALL BE PROVIDED BY OTHERS. SIEMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the same be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHN MAITREJ DATE SIG9ED: 02/19/2024 - CONTROL LOG: 2024-015 AGENCY REFERENCE: NICET LEVEL: IV FIRE ALARM SYSTEMS CERT: 104316 1 00 02/15/24 JISSUED FOR PERMIT APK N0. REV DATE REMARKS INTL DRAWN: AP K CHECKED: G N SHEET DESCRIPTION: FIRE ALARM SYSTEM THIRD LEVEL FIRE ALARM PLAN JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. NORTH THIRD LEVEL FIRE ALARM PLAN SCALE: 1 /V„ = 1 9_091 0 4' 8' 16' (D DRAWING NUMBER: FAI ■ 3 0 SHEET SIZE: ARCH E1 - 3002 APPROVAL STAMPS U U 0 0 N co I a> E 0 z U I 0 N Lam C N E Ln 0 i M 00 r— ro I a 0 I 0 a> c c 0 U 7 L c 0 U a U N a 0 E I a� c 0 U U 0 0 N 0 a 0 U o_ 0 N 0 N I NOTES ABBREVIATIONS: (N) NEW DEVICES N.I.C. NOT IN CONTRACT DRAWING NOTES: 1. ALL DEVICES OUTSIDE AREA OF WORK SHALL BE CONSIDERED AS EXISTING TO REMAIN. 2. ALL DEVICES NOT INDICATED WITH AN ASSOCIATED CALLOUT SHALL BE CONSIDERED AS EXISTING TO REMAIN. GENERAL NOTES: 1. CONTROL RELAY MODULES SHALL BE MOUNTED WITHIN 3FT FROM THE CONTROLLERS. KEY NOTES: 1. 24 VDC POWER SUPPLY FOR ALL WANDER DOORS SHALL BE PROVIDED BY OTHERS. 9 N.I.C. SCOPE OF WORK � I � =I VAA 1 1 1 Iz-no IC 1 (N) M� D A OP � WANDER � S OB CI UI � DOOR S 1, RELEASE 1 M ldmmmmm� iM no ter. E- M 1 1 1-153 1-152 1-151 1-150 1 1 (N) Et (N) <D (N) RM (D(N) RM / WANDER DOOR RELEASE .m = � = �. 1 -72,3 V, 4 W 1111111110011110MOM no M /000001111M�v ,Pr6V.4S 2-171 D A OP 4 (N) RM (j) P SI P W F WANDER L. S K U DS 1 DOOR A RELEASE 0 1-154 (N) RM 1 WANDER 1 DOOR 1 RELEASE r ,P, g# C 3/04" C 1EMENS SIEMENS INDUSTRY, INC. 15900 SE EASTGATE WAY BELLEVUE, WA 98008 425.507.4300 800.952.6348 (24-HR SERVICE) LICENSE: CC #SIEME11919PP This drawing and the information and design application herein contained is the property of SIEMENS INDUSTRY, INC. and is loaned upon the express condition that the same be returned to SIEMENS INDUSTRY, INC. upon request; all information herein contained shall be treated as secret and confidential; no reproduction of this drawing or part thereof shall be made without the written consent of SIEMENS INDUSTRY, Incorporated. REVIEWED THIS DRAWING PACKAGE HAS BEEN REVIEWED AND FOUND TO BE COMPLIANT WITH APPLICABLE REQUIREMENTS JOHN ITREJ AN NICET LEVEL: IV DATE SIG ED: 02/19/2024 FIRE ALARM SYSTEMS CONTROL LOG: 2024-015 CERT: 104316 AGENCY REFERENCE: RI I 1 00 02/15/24 ISSUED FOR PERMIT APK REV DATE REMARKS INTL 4 4S 4S, No. DRAWN: AP K E T A P —1 '2 P —1 24 P 12 4 CHECKED: G N S S— SHEET DESCRIPTION: FIRE ALARM SYSTEM :k SYSTEM RISER DIAGRAM PER ER JOB NUMBER: 440P-371895 PROJECT NAME \ ADDRESS: CHARTER CONSTRUCTION SUNRISE FA T.I. 0 0 L I SUNRISE OF EDMONDS, 750 EDMONDS WAY, EDMONDS, WA 98020. NORTH SYSTEM RISER DIAGRAM DRAWING 1 NUMBER: FA2m01 SCALE: NOT TO SCALE SHEET SIZE: ARCH E1 - 3002