Loading...
RESUB 1-FIR2023-0064+Fire_Alarm_Equipment_Specification_Sheets+9.20.2023_9.36.21_AM+3793459RESUB Sep 20 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SIEMENS Siemens Industry, Inc. FIS Fire \ Life Safety Division FIR2023-0064 15900 SE Eastgate Way Bellevue, WA 98008 425.507.4300 For information Contact: COLIN PINE colin.pine@siemens.com PRODUCT DATA SUBMITTAL 9/15/2023 Engineering Data for: SUNRISE SENIOR LIVING FA UPGRADE Fire Alarm System 750 EDMONDS WAY EDMONDS, WA 98233 440P-347628 THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING SIEMENS SIEMENS Industy, Inc. - Fire / Life Safety Division 15900 SE Eastgate Way Bellevue, WA 98008 Tel: 425.507.4300 1.1 r]dJA r]d N7-lsl rz SUNRISE SENIOR LIVING FA UPGRADE 750 EDMONDS WAY EDMONDS, WA 98233 FIRE ALARM SUBMITTAL TABLE OF CONTENTS MODEL NUMBER DESCRIPTION XLS / Desigo Modular EQUIPMENT XDLC Device Loop Card (Isolator compatible) CAB-BATT Battery Cabinet for (2) 100 A.H. Batteries Annunciators SSD-C System Status Display w/ Control XLS/Desigo Addressable Devices FDT421 Intelligent Thermal (Heat) Detector Head FDOT421 Intelligent Multi -Sensor Smoke/Heat Detector DB-11 Detector Base HMS-S Single -Action Manual Pull Station HCP Supervising Control Point Module XTRI-R Addressable Relay / Monitor Module with Dual Isolators XTRI-D Addressable Dual Monitor Module with Dual Isolators XTRI-S Addressable Monitor Module with Dual Isolators Batteries PS-121000 100 Amp -Hour 12VDC Battery THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING ❑ Supports up to 252 addressable points ❑ Operates and maintains all devices residing on up to four (4) 'Class A', eight (8) 'Class B' addressable circuits ❑ Compatible with Siemens intelligent, addressable'X' and 'H'-series devices: Multi -criteria / Carbon Monoxide (CO) Detector with ASAtechnology " Multi -criteria Detector with ASAtechnolog/M Multi -criteria Detector Thermal (Heat) Detector Input / Output Interface Module ❑ Polarity insensitive (in non -isolation mode) via SureWireTm technology: - Modern technology supports comprehensive system and interface communication ❑ Quantity 16 diagnostic light -emitting diodes (LEDs) for easy circuit diagnosis ❑ Microchip controls on -board isolators ❑ Device Programmer / Tester (Model DPU) programs and verifies device's address: - programming capabilities include testing a duct detector, as well as other Siemens addressable devices ❑ Supports 'Class B' 1 'Class A' I 'Class X' wiring ❑ Supports T-Tapping ❑ Degrade mode ❑ UL864 I CAN / ULC Listed SIEMENS The Siemens - Fire Safety Class X' Device Loop Card (Model XDLC) is the interface used for connecting Siemens addressable, intelligent 'X' as well as 'H'-series devices. Each Model XDLC plugs into one (1) slot of the Model CC-2 or Model CC-5 card cage. Programming for Model XDLC is accomplished via the Desigo Fire Safety Modular system custom -configuration tool, Zeus-D. Model XDLC takes one (1) address on the network, communicating up to a total 252 detectors and devices. Model XDLC has 16 LEDs for diagnostic purposes, and provides ground -fault detection and zone - isolation circuitry. The Class X' Device Loop Card (Model XDLC) initializes, operates and maintains all devices residing on up to four (4) 'Class A', eight (8) 'Class B' addressable circuits. Model XDLC communicates all relevant device and event data (-Alarm', -Trouble' and Supervisory' commands) to a Desigo Fire Safety Modular (Desigo Modular) fire - alarm control panel (FRCP), and supervises the device loop circuit. Model XDLC is polarity insensitive via SureWire technology, which greatly reduces commissioning time normally spent tracing down crossed -field wiring. Model XDLC communicates detector data, such as sensitivity of intelligent fire detectors and logic -function information, to the Desigo Modular Operating Unit (Model FCM2041- U2), which is located within a given Desigo Modular system. Each device loop card supports four (4) 'Class A', eight (8) 'Class B' circuits for up to a total of 252 addressable devices - as well as relay and audible bases, remote lamps and duct -detector housings in any combination. The microprocessor in a Model XDLC controls the on -board isolation, in case there is a fault (short) in any of the circuits, thus allowing the other circuit to continue operating. For continuous protection, the on -board microprocessor continues to operate even in the event of a CPU failure. NOTE: Refer to installation manual: WIN - A6V101040156 to ensure Model XDLC compatibility with the Siemens FACPs intended for use in the given application. Ukm Side View _ Front View Siemens Smart Infrastructure - Building Products Data Sheet 7312 usa.siemens.comlfire in 'Class X' Device Loop Card 1 to a Siemens Card Cage 'Class X' Device Loop Cards are UL Listed I ULC Listed for indoor dry locations within a temperature range of 120'/-3°F (49'/-2°C) to 32'/-3°F (O'I-2°C) and a relative humidity of 93'I-2% at a temperature of 90'/-3°F (32'/-20C). Technical Data 24V CURRENT DRAW: 0 [Back Plane] 24V CURRENT DRAW: 100mA + 1.4mA [Screw Terminal] pertlevice 6.2V CURRENT DRAW: 1 mA, max. [Back Plane] 24V CURRENT DRAW: 100mA+ 1.4mA [Standby] per device DEVICE LOOP: 500mA, max. [@ 30 VDC Max.] (power limited) NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS Details forOrdering MODEL PART OR TYPE NUMBER PRODUCT XDLC S54430-138-A1 Class X Device Loop Card SIEMENS Product ❑ One (1) 1 two (2) 1 three (3) row enclosure The enclosures used with Desigo Fire Safety Modular systems (Models CAB1, types CAB2, and CA133), along with their accessories, provide a complete set of hardware for mounting all main system and remote transponder cards and ❑ Blank plates (ordered separately) for inner modules. and outer doors The hardware allows each DSFM system to be configured for a wide variety of ❑ Clear lens and grill plates (sold separately) applications. Included in the enclosure series are backbox and door sets; for use with outer door removable mounting plates and clear lenses; louvered ventilation grill plates, ❑ UL 864 Listed, ULC Listed and blank plates for use with the enclosure doors. All enclosures come with ground straps for the inner and outer doors; shield termination lugs; grounding lugs, and tie wrap lances for securing wire. All enclosures can also mount system backup batteries up to 31AH in capacity. &' I �� One -row system enclosure [with mounted optional [with mounted optional u inner door] inner door] Siemens Data Sheet 7327 Smart Infrastructure — Building Products usa.siemens.comlfire Single -Row Enclosure Model CAB1, the smallest of the Desigo Fire Safety Modular system enclosures, can house a single Model CAB -MP cabinet mounting plate for mounting card cages, power supplies and bulk amplifiers. Model CAB1 also has four (4) mounting slots on the inner door for mounting an Operator Interface (01) and Model ID -MP switch module brackets. Each Model CAB1 comes complete with a black back box, with black inner and outer doors, a single lock - and -key set on the outer door, and a single OD -LP outer door lens plate (installed). A red version (Model CAB1 R) is also available. Approximate size is 27" (68.6cm.) high; 26" (66cm.) wide, and 8" (20.3cm.) deep. Two -Row Enclosure Model CAB2 is the mid -sized Desigo Fire Safety Modular enclosure capable of housing a maximum two (2) Model CAB -MP cabinet mounting plates. The inner door has two (2) rows of four (4) mounting slots. The outer door has space for mounting two (2) outer door plates (Models OD -LP, OD - BP or OD -GP). The outer door can be configured to open from either side. Model CAB2 consists of the Model CAB2-BB back box; the Model CAB2- BD black inner and outer door package, and one (1) Model OD -LP lens plate. The outer door has a single lock and key set installed. Red doors are available in Model CAB2-RD. Additional door mounting plates must be ordered separately. Approximate size is 45" (114.3cm.) high, 26" (66cm.) wide, and 8" (20.3cm.) deep. Three -Row Enclosure Model CAB3, the largest single Desigo Fire Safety Modular enclosure available, can house a maximum three (3) Model CAB -MP cabinet mounting plates in the enclosure, and three (3) rows of inner door mounting slots. The outer door can be configured to open from either side. Model CAB3 consists of the Model CAB3-BB back box; the Model CAB3-BD black inner and outer door package, and one (1) Model OD - LP lens plate. The outer door has two (2) locks and key sets installed. Red doors are available via Model CAB3-RD. Additional door mounting plates must be ordered separately. Approximate size is 63" (160cm.) high, 26" (66cm.) wide, and 8" (20.3cm.) deep. Enclosure Trim Kits Trim kits are available for all system enclosures for semi -flush mounting applications. Model CAB1-TK (for black enclosures) and Model CAB1 R-TK (for red enclosures) fit Models CAB1 and CAB1-R enclosures. Similarly, Models CAB2-TK and CAB2R-TK fit the Model CAB2 enclosure, and Models CAB3-TK and CAB3R-TK fit the Model CAB3 enclosure. CAB2-XBD CAB3-XBD Remote Transponder Doors The Desigo Fire Safety Modular system can use remote transponders for mounting additional modules such as amplifiers, without requiring an Operator Interface (01) or any control switches. Special doors are available for systems using Model CAB2 or Model CAB3 remote transponders. Models CAB2-XBD and CAB3-XBD omit the unused inner door and come complete with ventilation louvers built into the door. Model CAB2-XBD comes in black, and fits specifically on Model CA132- BB. Model CAB3-XBD also comes in black, and fits specifically on Model CAB3-BB. Remote transponder doors are also orderable in red: Models CAB2-XRD and CAB3-XRD. Outer -Door Grill Plate Model OD -GP also covers an entire row on the outer door of a system cabinet, but has four rows of ventilation louvers on it. Model OD - GP is mounted in front of system bulk amplifiers, card amplifiers, or other modules that generate heat. Using Model OD -GP will permit airflow across these modules to aid in heat dissipation. A single grill plate is included with each Model OG-GP. Remote System Enclosures Models REMBOX2 and REMBOX4 are Desigo Fire Safety Modular system enclosures that are used for remotely mounting inner -door modules, such as the Desigo Modular 01, Model SCM-8, Model LCM-8 and Model FMT. REMBOX4 hardware used with Desigo Fire Safety Modular systems are thinner than the regular CAB enclosures, just 5" (12.7cm.) deep overall, and are perfect for mounting in places where space is limited (such as lobbies or behind a receptionist's desk). Due to their smaller depth, no card cages, power supplies or bulk amplifiers can be mounted in a given REMBOX. However, modules such as the Remote Network Interface Module (Model RNI); the Output -Control Module (Model OCM-16) and the Supervised Input Module (Model SIM- 16) can be mounted in a REMBOX. Due to the depth of the Live Voice Module (Model LVM) and the Model FMT firefighters' master telephone, no Model OCM-16 or Model SIM-16 modules can be used simultaneously with Model LVM or Model FMT. Models REMBOX2 and REMBOX4 are designed for flush mounting with no trim kit required. Both enclosures also come with a clear lens plate on the cover. Siemens _ usa.siemens.comlfire Smart Infrastructure — Building Products _2 (with doors closed) (with doors open) Two -Module Remote Enclosure Model REMBOX2 has two (2) inner - door module spaces, and can hold on Desigo Modular 01, up to two (2) switch -module brackets, one (1) Model LVM. Combinations are permissible. Model REMBOX2 can also mount a single Model RNI on a bracket included in the backbox. A bracket (Model REMBOX2-MP) can be used to mount up to four (4) Model OCM-16s or Model SIM-16 enclosures. Model REMBOX2-MP must be purchased separately. Approximate size of Model REMBOX2 is 14-1 /2" (36.8cm.) wide, 18-112" (47cm.) high and 5" (I 2.7cm.) deep. NOTE: A red, (2) two -module remote lobby enclosure (Model REMBOX2R) is also available. Four -Module Remote Enclosures Model REMBOX4 has space for mounting four (4) inner door modules. Any combination (two - module spaces), switch module brackets, Model LVM or Model FMT (one -module space each) on a Desigo Modular OI can be used. Unused module spaces can be covered with Model ID-SP blank plates. Cabinet Mounting Plate The cabinet mounting plate (Model CAB -MP) provides mounting for a single row of modules in a Desigo Modular system cabinet. Four (4)-module spaces are available on Model CAB -MP. Model CAB -MP is used to mount the Model CC- 5 card cage, the Model CC-2 card cage, the Model PSC-12 power supply, the Model PSX-12 power supply extender, and the Model ZAM-80 I 180 zone amplifiers. Inner -Door Mounting Plate The inner door mounting plate (Model ID -MP) is mounted on the inner door of a CAB enclosure. Model ID -MP plates are used to mount Model SCM-8 switch control modules; Model LCM-8 LED control modules, or with Model FCM-6. Four (4) mounting plates are included in each Model ID -MP. Each mounting plate has four (4) spaces for control modules, and can hold either four (4) Model SCM- 8 modules {one [1 ] control module space each}; four (4) Model LCM-8 modules {one [1 ] control module space each}; or two (2) Model FCM-6 modules {two [2] module spaces each}. Combinations are also allowed. Blank spaces in Model ID -MP can be covered using the Model BCM blank control module plate. A maximum four (4) Model ID -MP plates can be mounted in a single row on the inner door. Inner -Door Single Blank Plate Model ID-SP is used to cover any single module blank spaces on the inner door not used to mount a Desigo Modular OI or one (1) Model ID -MP. Up to four (4) Model ID-SP plates can be mounted in a single row on the inner door. Two (2) blank plates are included in each Model ID-SP. Class X Assembly Plate The XDACT Assembly (Model XDACT-ASSY) is the blank plate used for holding the optional Digital Alarm Communication Transmitter (DACT), Model FCA2015-U1. The XDACT assembly vertically mounts on the back, left-hand side of an inner door of any type of Desigo Modular panel, adjacent to an Operator Interface (01). Model BCM Blank Control Module Plate Model BCM is used on Model ID - MP to cover any blank areas where control modules are not used. A maximum four (4) Model BCM plates can be mounted on a single Model ID -MP. Four (4), blank - module plates are included in each Model BCM. Outer Door Lens Plate Model OD -LP is a clear plastic lens plate mounted on the outer door of a system cabinet. Model OD -LP is used to allow operators to see the system interface and controls mounted on the inner door, but restricts access to unauthorized users. Model OD -LP covers an entire row on the outer door. A single lens plate is included with each Model OD -LP. Siemens Smart Infrastructure — Building Products —3— usa.siemens.comlfire Outer Door Blank Plate The Outer Door Blank Plate (Model OD -BP) is used to cover an entire row of a Desigo Modular system cabinet. Model OD -BP is mounted when no module is used in that location. Model OD -BP is mounted on the outer door, and one (1) blank plate is included with each order. Inner Door Outer Door Adapter Plate MME-3—series Enclosure Adapters Model XLS-MME3-ADPT, which must be used in conjunction with Model CAB -MP plates, is an adapter that allows Desigo Modular cards to be mounted in older -generation MXL Model MME-3—series or Model MBR-2 medium black enclosures. Model XLS-MME3R-ADPT, which must be used in conjunction with Model CAB -MP plates, is an adapter that allows Desigo Modular cards to be mounted in older -generation MXL Model MME-3R medium red enclosures. oor Door dapter D Plate MSE-3—series Enclosure Adapters Model XLS-MSE3-ADPT is an adapter that allows Desigo Modular cards to be mounted in older -generation MXL-IQ Model MSE-3L or Model MSE-3M black enclosures. Model XLS-MSE3R-ADPT is an adapterthat allows Desigo Modular cards to be mounted in older -generation MXL-IQ Model MSE-3LR or Model MSE-3MR red enclosure. Plate RCC13-series Enclosure Adapters Model XLS-RCC13F-ADPT is an adapter that allows the Desigo Modular Model SSDI-C series remote annunciator to be mounted in older -generation Model RCC- 1 F or Model RCC-3F black, flush -mount enclosure. Model XLS-RCC13FR-ADPT is an adapter that allows the Model SSDI-C series to be mounted in older -generation RCC-1 FR and RCC-3FR, red flush -mount enclosure. M Plate mo ! RCC-1—series Enclosure Adapters Model XLS-RCC1-ADPT is an adapter that allows the Desigo Modular Model SSDI-C series remote annunciator to be mounted in older -generation Model RCC-1 surface - mount enclosure. Remote Transponders Desigo Modular systems can use remote transponders for mounting additional modules such as amplifiers without requiring a Desigo Modular operator interface or any control switches. Special doors are available for systems using Model CAB2 or Model CAB3 remote transponders. These doors (Models CAB2-XBD and CAB3- XBD) omit the unused inner door, and come complete with ventilation louvers built into the door. Special doors are available for systems using Model CAB2 or Model CAB3 remote transponders. These doors (Models CAB2-XBD and CAB3-XBD) omit the unused inner door, and come complete with ventilation louvers built into the door. Enclosure Trim Kits Trim kits are available for all Desigo Modular system enclosures for semi -flush mounting applications. Model CAB1-TK (for black enclosures) and the Model CAB1 R- TK (for red enclosures) fit inside the Models CAB1 and CAB1 R enclosures. Similarly, Models CAB2- TK and CAB2R-TK fit inside the Model CAB2 enclosure, while Models CAB3-TK and CAB3R-TK fit the Model CAB3 enclosure. Siemens _ Smart Infrastructure — Building Products _4 usa.siemens.comlfire IM MODEL PART PRODUCT OR TYPE NUMBER Blank Control BCM 500-033320 Module Plate [Four (4) per package] Field -mounted CAB-BATT 500-633917 enclosure for 100AH batteries, black Field -mounted CAB-BATT-R 500-634925 enclosure for 100AH batteries, red Complete Single -Row CAB1 500-633007 Cabinet, black CAB1R 500-633728 Complete Single -Row Cabinet, red CAB1-TK 500-633013 Single -Row Trim -kit Cabinet, black CAB1 R-TK 500 633729 Single -Row Trim -kit Cabinet, red CAB2-BB 500-633009 Two -Row Back Box, black CAB2-RB 500 634941 Two -Row Back Box, red Two -Row Inner & CAB2-BD 500-633008 Outer Door Set, black CAB2-RD 500-633755 Two -Row Inner & Outer Door Set, red CAB2-TK 500-633014 Two -Row Trim -kit Cabinet, black CAB2R-TK 500-633753 Two -Row Trim -kit Cabinet, red CA132-XBD 500-633768 CAB2 [Transponder Door Medium -Enclosure CAB2-XRD 500-633792 Transponder Door [mounts to Model CAB2-RB CAB3-BB 500-633011 Three -Row Back Box, black CAB3 RB 500-634942 Three -Row Back Box, red Three -Row Inner & CAB3 BD 500-633010 Outer Door Set, black CAB3-RD 500-633757 Three -Row Inner & Outer Door Set, red CAB3-TK 500-633015 Three -Row Trim -Kit Cabinet, black CAB3R-TK 500-633754 Three -Row Trim -Kit Cabinet, red CAB3-XBD 500-633769 CAB3 Transponder Door Large -Enclosure CAB3-XRD 500-633793 Transponder Door [mounts to Model CAB3-RB] MODEL PART PRODUCT ORTYPE NUMBER Module CAB -MP 500-633012 Mounting Plate Bracket to hold down 55AH batteries in CAB-55-BRKT S54430-B1-A1 CAB-BATT enclosure [ Required for Seismic Applications ] Bracket to hold down 100AH batteries in CAB-100-BRKT S54430-132-A1 CAB-BATT enclosure [ Required for Seismic Applications ] ENCL-01 S54465-C63 AlFSN,Uclosure y-lock) Inner -Door Enclosure ID -MP 500-633027 Mounting Plate [four (4) per package] Single -Door Inner -Door ID-SP 500-633028 Enclosure Mounting Plate [two (2) per package] OD -BP 500-633017 Outer Door Blank Plate, black OD-BP-R 500-634919 Outer Door Blank Plate, red OD -GP 500-633018 Outer Grill Plate, black OD-GP-R 500-634920 Outer Grill Plate, red OD -LP 500-633016 Outer Door Lens Plate (2) Two -module REMBOX2 500-633772 remote lobby enclosure, black (2) Two -module REMBOX2R 500-650612 remote lobby enclosure, red Mounting plate for REMBOX2-MP 500-634211 Models OCM-16 / SIM-16 in Model REMBOX2 (4) Four -module REMBOX4 500-633914 remote lobby enclosure, black (4) Four -module REMBOW 500-650613 remote lobby enclosure, red Mounting plate for REMBOX4-MP 500-634212 Models OCM-16 / SIM-16 in Model REMBOX4 MODEL PART PRODUCT OR TYPE NUMBER XDACT-ASSY S54430-A5-A1 XDACTMounting Plate (with cable) XLS-MLE6-ADPT S54430-C9-A1 MLE-6 Enclosure Adapter, black XLS-MLE6R-ADPT S54430-C9-A2 MLE-6R Enclosure Adapter, red MME-3 and MBR-2 XLS-MME3-ADPT S54430-C8-A1 enclosure adapters, black XLS-MME3R-ADPT S54430-C8-A2 MME-3 and MBR-2 encl. adapters, red XLS-MSE2- MSE-2 enclosure ADPT S54430-C7-A1 adapter, black XLS-MSE2R-ADPT S54430-C7-A2 MSE-2 enclosure adapter, red MXL-IQ I MSE-3L & XLS-MSE3-ADPT S54430-C14-A1 MSE-3M enclosure adapters, black MXL-IQ I MSE-31_ & XLS-MSE3R-ADPT S54430-C14-A2 MSE-3M enclosure adapters, red XLS-RCC1-ADPT S54430-Z14-A1 RCC-1 enclosure adapter, black RCC-1 F I RCC-3F XLS-RCC13F-ADPT S54430-Z13-A1 enclosure adapter, black RCC-1 F I RCC-3F XLS-RCC13FR-ADP S54430-Z13-A2 enclosure adapter, red Siemens _ usa.siemens.comlfire Smart Infrastructure — Building Products _5 NOTICE— The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets —as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS ❑ 4 rows - 40-character alphanumeric LCD screen, backlit upon status change or display toggling ❑ Audible and event -status light -emitting diodes (LEDs) ❑ Scroll buttons to view additional events ❑ Local sounder ❑ Supports 'Class B' or'Class A' wiring ❑ Built-in transient protection ❑ Mounts in its own enclosure or REMBOX-series enclosure ❑ Optional local -system control ❑ Downloadable firmware ❑ UL864 & CAN / ULC-S576 Listed SIEMENS Auct Overview The System -Status Display (SSD Series) is a remote light -emitting diode (LED)/ liquid -crystal display (LCD) display unit that shows the local status of a Desigo Fire Safety Modular system. A LED will illuminate when Alarm I Supervisory I Trouble and Security events occur on the system. A (4) four -line LCD will give details of the event in alphanumeric form. The display can be toggled to display additional events. Optional remote -system -control capabilities are available. •- • The SSD Series display has separate LEDs for Alarm Supervisory I Trouble and Security events on the Desigo Fire Safety Modular system. Each LED will flash when unacknowledged events of that type are present on the system. The LED will change to steady, upon acknowledgment of the event. Also, there are two (2) LEDs that indicate the state of audible circuits on the system: one (1) LED to indicate that the circuits are active and one (1) LED to indicate the circuits have been silenced. The LCD display on the Model SSD-series display has four (4) rows — 40 characters for each row. When the Desigo Fire Safety Modular system is in its normal supervisory state with no events present, the display will annunciate the system ID information, the date and the time of day. When an event occurs on the system, the LCD display will show the event type and address, the time of the event, the custom message for that address, the usage of the device, and whether the event is acknowledged' or not. Additionally, the display will show the total number of all types of events present on the system. The display has a backlight feature that operates upon receiving any event information or when any operator buttons are pressed. System -Status Display Series (with control for remote enclosures) System -Status Display Series A local sounder is included with the Model SSD-series display that operates when any events are displayed on the system. The sounder can be optionally disabled through software programming. Pressing any operator buttons will silence the local sounder when an event is present. The SSD Series display has two (2) display -control buttons that are used to display the next or the previous event information in the sequence, and a local sounder silence button. Programming for the SSD Series display is done with the Zeus-D programming tool. Siemens Smart Infrastructure - Building Products Data Sheet 7326 usa.siemens.com/fire Models SSD-C and Model SSD-C-REM have three (3) additional control buttons for acknowledging events, silencing audible circuits, and resetting the system. Model SSD-C has an integral key switch that enables these control buttons to operate. Model SSD-C-REM is located within a locked cabinet, so no additional key switch is required for enabling the control buttons. The SSD Series display is remotely connected to the H-Net communication bus from any Model NIC-C interface in a Desigo Fire Safety Modular system enclosure using Class B or Class A wiring. 24VDC is required to run the SSD Series display, and can be provided from a Model PSC-12 Power Supply or PSX-12 Power Supply Extender in the Desigo Fire Safety Modular system enclosure. Power from other UL Listed 24VDC power sources is also acceptable. The SSD Series display has screw terminals capable of supporting 12 to 22-gage wires. The H-Net communication from the Desigo Fire Safety Modular system can be terminated on the SSD Series display, or may pass through for communication with other modules. Diagnostic LEDs on the SSD Series display indicate power and communication status. Models SSD and SSD-C can be mounted in a (2) two -gang electrical box or a (4) four -inch square electrical box. No flush -trim kit is required. The unit is approximately 10-112" (26.7cm.) wide, 6-118" (15.2cm.) high, and1-112" (3.8cm.) deep. The Model SSD-C-REM is mounted in a Model REMBOX2 or Model REMBOX4 Remote Lobby Enclosure, or any CAB enclosure inner door. Model SSD-C-REM requires two (2) module spaces in the remote lobby enclosure, and its bracket supports the mounting of four (4) inner door modules (such as Model SCM-8 or Model LCM-8 modules) below the display. The inner door module spaces are arranged in two (2) rows of (2) two -module spaces. Products are UL 864 10th Edition Listed for indoor dry locations within a temperature range of 120+1-3°F (49+1-2°C) to 32+1-3°F (0+1-2°C) and a relative humidity of 93+I-2% at a temperature of 90+I-3°F (32+1-2°C). Electrical Ratings SSD-C TYPICAL 200mA (max) at 24 VDC INPUT VOLTAGE 24 VDC (Nominal) ( 31 VDC max ) filtered NOTE: An auxiliary -regulated, power -limited power supply may be used to provide power to Model SSD. The power supply must be UL Listed for Fire -Protection Signaling Application. Be sure to also include Model SSD-C in the battery calculations. SSD I SSD-INTL TYPICAL 200mA (max) at 24 VDC INPUT VOLTAGE 24 VDC (Nominal) ( 31 VDC max ) filtered NOTE: An auxiliary -regulated, power -limited power supply may be used to provide power to Model SSD. The power supply must be UL Listed for Fire -Protection Signaling Application. SSD-C-REM TYPICAL 200mA (max) at 24 VDC INPUT VOLTAGE 24 VDC (Nominal) ( 31 VDC max ) filtered NOTE: An auxiliary -regulated, power -limited power supply may be used to provide power to Model SSD-C-REM. The power supply must be UL I ULC approved for Fire Protection Signaling Application. Be sure to also include Model SSD-C-REM in the battery calculations. MODEL PART PRODUCT OR TYPE NUMBER SSD E0-03417] System-Status Display SSD-C 500-648733 System -Status Display [with control] System -Status Display SSD-C-REM 500-634773 [with control for remote -lobby enclosure] REMBOX2 500-633772 Small Remote -Lobby Enclosure REMBOX4 500 633914 Large Remote -Lobby Enclosure BCM 500-033320 Blank Control Module Plate Siemens Smart Infrastructure — Building Products —2— usa.siemens.comlfire NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING ❑ Built-in ISOtechnologyTM ❑ Compatible with Siemens Model ' H'- series devices on the same loop (with Desigo Fire Safety Modular I FireFinder XLS/V I FC/FV20-series fire -alarm control panels ❑ Contains seven (7) field -selectable settings in a temperature range of 135°F - 175°F (57.2°C - 78.9°C) ❑ Provides a low -temperature warning of 40°F (4.4°C) ❑ Field programmable as rate -of -rise or fixed temperature ❑ Tri-color detector -status light -emitting diode (LED) with 360 'view ❑ Compatible with Model DPU (device programmer / loop tester) ❑ Utilizes advanced, microprocessor -based signal processing ❑ Each detector is self -testing: - complete diagnostics performed every 10 seconds ❑ Polarity insensitive via SureWireTM technology ❑ Functions with Model DB-11-series mounting bases ❑ Superior electromagnetic interference (EMI) and radio -frequency interference (RFI) immunity ❑ Restriction of Hazardous Substances (RoHS compliant) ❑ UL 521 Listed, ULC Listed; CSFM (#7272- 0067:0258) Approved SIEMENS ProductOverview The Intelligent Thermal (Heat) Detector (Model FDT421) provides an advanced method of detection, address programming supervision - combined with sophisticated FACP communication. Model FDT421 uses a state-of-the-art thermistor, microprocessor and advanced signal analysis, providing high reliability and accuracy. Additionally, Each Model FDT421 unit is UL listed including advanced built-in ISOtechnologyTm - a "True Class-V SLC operation (use is optional) greatly improving system reliability and circuit integrity while providing advanced addressable fault finding. Each model FDT421 is a cost-effective, two -wire I addressable thermal detector that provides a distinctive, advanced feature: seven (7) field -selectable temperature settings specially tailored for application -specific detection needs combined with Class- X SLC operation built-in avoiding additional installation and material cost. The temperature -range settings for each Model FDT421 detector is between 1357 (57°C) - 175°F (79°C) with fixed and rate -of -rise programmability. This variance provides the customer with maximum flexibility to program the temperature settings to suit multiple application needs and changing environmental conditions. Model FDT421 can be configured to provide a low -temperature warning signal at 407 (4.4°C). This feature - along with a compatible FACP (Design Fire Safety Modular I FireFinder XLS/V or with Desigo FC /FV2025 or FC /FV2050 FACPs) - serves as prevention of water freezing in pipes for sprinkler systems, meeting NFPA 72. Model FDT421 also utilizes a modern, accurate and shock -resistant thermistor to sense significant changes in temperature. Each Model FDT421 detector has seven (7) pre-programmed parameter sets that can be selected by the Siemens FRCP. raw Thermal (Heat) Detector Siemens Smart Infrastructure - Building Products Data Sheet 6151 usa.siemens.com/fire 1. Thermistor Model FDT421 RED conditions: 1. Dust cover 2. Thermal (heat) detector NOTE: Each detector consists of a dust -resistant chamber, a solid state, functional internal sensor, and microprocessor -based electronics with a low -profile plastic housing. Every Model FDT421 fire detector is shipped with a protective dust cover. !rvision and Testing contains a tri-color LED indicator, capable of flashing any one (1) of three (3) distinct colors: GREEN During each flash interval, the microprocessor -based detector monitors the following fire -system Temperatures reaching programmed thresholds Internal sensors and electronics are functional Based on the results of the monitoring, the LED indicator flashes the following: FLASH COLOR CONDITION FLASHINTERVAL [in seconds] Normal supervisory operation. GREEN*: Temperature has not reached programmed 10 alarm thresholds or set points. YELLOW: Detector is not operating at 4 normal capacity and needs replacement. Alarm' condition 1 NO FLASH: Detector is not powered. — * denotes LED can be turned OFF Please follow the corresponding description of the panel used. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the respective Desigo Fire Safety Modular FireFinder XLSIV or Model FC20-series FACPs that indicates the status and settings assigned to each individual detector. M__W W All Model FDT421 detectors use a surface -mounting base, Model DB-11 or Model DB-11 E, which mounts on a 4-inch (10.2 cm.) octagonal, square or single -gang electrical box. The base utilizes screw -clamp contacts for electrical connections and self -wiping contacts for increased reliability. The Model DB-11 detector base can be used with the optional Siemens Model LK-11 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has aesthetically conducive plugs to cover the outer mounting -screw holes. Model FDT421 may be installed on the same initiating circuit with the Siemens Model 'H'-series detectors and devices [when used with Desigo Fire Safety Modular I Model FC20-series I FireFinder XLSIV FACPs] — • HFP-11, HFPT-11 • Model 'XTRI' - series interfaces • Model 'XMS' - series manual stations • Model 'HTRI' - series interfaces • Model'HMS'- series manual stations • Model'HCP' - output control modules • Model 'HZM' - series of addressable, conventional zone modules Siemens Smart Infrastructure - Building Products —2— usa.siemens.comlfire Installation of Model FDT421 intelligent, addressable thermal detector requires a two -wire SLC circuit. In many retrofit cases, existing wiring may be used. 'T-tapping' is permitted only for Style 4 (Class B) wiring. Model FDT421 is polarity insensitive when not used in Class-X mode, which can reduce installation and debugging times. The unit's value is multiplied with built-in ISOtechnology the True Class-X - NFPA 72 compliant SLC isolation feature, supporting up to 252 isolation ready devices per loop. When used in mixed mode a maximum of 30 non -isolated devices between isolation devices (wired in polarity -insensitive mode). Each detector fits into one (1) wall -or -ceiling footprint, and only occupies one (1) address on the signal -line circuit (SLC). Model FDT421 can be applied within the maximum 50-feet (15.24 m.) center spacing (2,500 sq. ft. [232.3 sq. m.1) per Underwriters' Laboratories. This application guide is based on ideal conditions, specifically, smooth -ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors in close proximity to heating I ventilation I air-conditioning (HVAC) outlets. Exposed joists or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire -protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens - Fire Safety distributor or sales office whenever you need assistance applying Model FDT421 in unusual applications. Be sure to follow NFPA guidelines and UL Listed I ULC Listed installation instructions included with every Siemens - Fire Safety detector - and local codes for all fire -protection equipment. Model FDT421 is a plug-in, (2) two -wire thermal (heat) detector, compatible with Desigo Modular I FireFinder XLSIV and Model FC20-series FACPs. Each Model FDT421 detector has microcomputer -chip technology and highly stable, solid-state electronic circuitry. Model FDT421 detectors utilize a modern, accurate and shock -resistant thermistor to sense temperature changes. This electronic -sensing method virtually eliminates thermal lag associated with mechanical temperature -sensing devices and provides almost instantaneous temperature status to the FRCP. Model FDT421 provides seven (7) field -selectable, pre-programmed temperature settings: Fixed Temperature set points (5) Rate of Rise set points (2) • Fixed 135°F (57°C) • Fixed 145°F (63°C) • Rate -of -Rise: 15°F 1 min. (8.3°C) at fixed 135°F (57°C) • Fixed 155°F (68°C) • Rate -of -Rise: 15°F I min. (8.3°C) at fixed 175°F (79°C) — — — • Fixed 165°F (74°C) • Fixed 175°F (79°C) Additionally, the Model FDT421 detector has the following optional feature: • Model FDT421 provides indication of potential water freezing for sprinkler systems, via configuration for reporting a low -temperature warning of 40°F (4.4°C). This feature is compatible with Desigo Modular systems, as well as with FireFinder XLSIV and Desigo FCIFV2025 or FCIFV2050 FACPs. 4.13" (14.5 cm.) 0 AM Siemens Smart Infrastructure - Building Products -3- usa.siemens.comlfire Model FDT421 is compatible with the Siemens field -device programmer / test unit (Model DPU), which is a compact, portable and menu -driven accessory for electronically programming and testing these addressable detectors promptly and reliably. For instance, the field technician selects the accessory's program mode, and enters the desired address. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods (e.g. — dials and rotary switches), and reduces installation and service costs by electronically programming and testing the detector prior to installation. When set in 'test' mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Each field -device programmer / test unit operates on AC power or rechargeable batteries, providing flexibility and convenience in the programming / testing of fire -safety equipment from practically any location. Additionally, with the use of a Model DPU unit, there is no longer a cause for concern with any vibration, corrosion and other deteriorating conditions that can accompany the vitality of a mechanical -addressing mechanism. The encompassing result is an intelligent detector that provides enhanced detection capability to a wide range of products of combustion — while offering unsurpassed rejection to nuisance -alarm sources, including: dust I steam I aerosols and other deceptive phenomena that could cause false alarms. Technical Data '32°-'120°F (0°-'49°C) [with 145°F (63°C) 1155°F (68°C) OPERATING 11657 (74°C) and 175°F (79°C) TEMPERATURE: alarm -threshold settings] 132°-'1007, (0°-'38°C) [With 135°F (57°C) alarm threshold setting] Model FDT421 provides seven (7) field -selectable, pre-programmed temperature settings: • Fixed 135°F (57°C) • Fixed 145°F (63°C) • Fixed 155°F (68°C) THERMAL • Fixed 165°F (74°C) RATING: Fixed 175°F (79°C) Rate -of -Rise: 15°F/ min.(8.3°C) at fixed 135°F (57°C) Rate -of -Rise: 157/ min.(8.3°C) at fixed 175°F (79°C) RELATIVE 0 - 95% HUMIDITY: (non -condensing) AIR PRESSURE: No effect INPUT VOLTAGE 16VDC - 30VDC RANGE: ALARM' 410pA CURRENT, MAX: 'STANDBY' 250pA CURRENT, MAX: MAXIMUM 50-ft. (15.24 m.) centers SPACING: (2500 sq. ft. 1232.3 sq. m.), per NFPA 72 and ULC-S524 DETECTOR 0.317 Lbs. (0.144 kg.) WEIGHT: CompatibilitiesPanel MODEL DATA OR SHEET PANEL TYPE XLS 6300 FireFinder (fire) XLSV 6340 FireFinder (fire w/ voice) Desigo Modular 7300 Desigo Modular (overview) FC2005 6813 Desigo Fire Safety 50-point addressable FC2025 Desigo Fire Safety 252-pt. addressable (fire) 6815 FC2050 Desigo Fire Safety 504-pt. addressable (fire) Desigo Fire Safety FV2025 252-point addressable (fire w/ Intelligent Voice Communication [IVC]) 6821 504-pt. addressable FV2050 (fire w/ Intelligent Voice Communication [IVC]) Details for Ordering MODEL PART OR NUMBER PRODUCT TYPE FDT421 S54320-F5-A1 Thermal (Heat) Detector Compatible Devices MODEL PART OR NUMBER PRODUCT TYPE Sounder base with Loop - ABHW-4B S54320-F13-A1 Power Option Sounder base for ABHW-0S S54320-F14A1F Sleeping Areas Surface Mount Adapter Box ADB-BOX 500-698360 for Audible Base Relay base compatible with DB2-HR S54370-F12-A1 Siemens standard and advanced detectors Detector DB-11 500-094151 Mounting Base DB-11E 500-094151E Detector Base, small Remote Alarm Indicator: RL-HC 500-033230 4"(10.2 cm) octagon -box mount, red RL HW 500 033310 Remote Alarm Indicator: single -gang box mount, red LK-11 500-695350 Base Locking Kit See: www.STI-USA.com for further details on ordering Model STI-9604 In Canada order: MODEL OR PART PRODUCT NUMBER TYPE Detector Mounting DB-11C 500-095687 Base, ULC Listed Siemens Smart Infrastructure - Building Products —4— usa.siemens.com/fire NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING ❑ UL 268 7th Edition Listed ❑ Built-in ISOtechno/ogyTM ❑ 252 Isolation devices per SLC ❑ Each detector is self -testing: complete diagnostics performed every 10 seconds self -monitored for sensitivity within UL Listed limits ❑ Listed, approved as a heat detector: Rate -of -Rise Detection: 15°F / min. (8.3°C / min.) Fixed: 135°F (57°C) ❑ Superior electromagnetic interference (EMI) and radio -frequency interference (RFI) immunity ❑ Field programmable as rate -of -rise or fixed temperature, per Alarm Source 2' 1 Standard parameter ❑ Tri-color detector -status light -emitting diode (LED) with 360' view ❑ Compatible with Model DPU (device programmer / loop tester) ❑ Polarity insensitive via SureWireTM technology (in non -isolator mode) ❑ Functions with Model DB-11-series mounting bases ❑ Restriction of Hazardous Substances (RoHS compliant) ❑ Automatic environment compensation ❑ UL Listed I FM, CSFM Approved UL 268: 'Open Area Smoke Detection' UL 268A (Duct) - Direct -in -Duct' use UL 521: Open Area Heat Detection' ULC-S529:'System Smoke Detector' ULC-S530: Heat Actuated Fire Detection' FM 3230:'Open Area Smoke Detection' FM 3210:'Open Area Heat Detection' CSFM I File: 7272-0067:0258 SIEMENS The Photoelectric I Thermal (Heat) Detector (Model FDOT421) is an intelligent, addressable multi -criteria detector that incorporates optical and thermal sensors, and uses signals in a neural network to create an intelligent multi -criteria detector. The encompassing result is a detector that provides enhanced detection to a wide range of products of combustion. Model FDOT21 is UL 268 7th Ed. listed and incorporates advanced built-in ISOtechnologyrM - True Class-X SLC operation (use is optional) greatly improves reliability, circuit integrity and provides advanced addressable fault finding. The multi -criteria detector additionally has state-of-the-art microprocessor circuitry (with error check), as well as detector self -diagnostics and supervision programs that is used on Desigo Fire Safety Modular I FireFinder XLS/V and on Model FC/FV20-series Desigo Fire Safety fire -alarm control panels (FACPs). Additionally, Model FDOT421 is a plug-in and addressable two -wire multi -criteria detector (with both photoelectric and thermal sensors) whose value is increased with built-in ISOtechnology feature, that is compatible with all current Siemens intelligent, addressable systems. Operation Model FDOT421 utilizes an infrared light emitting diode (IRLED), and infrared light -sensing photodiode. Under normal conditions, light transmitted by the LED is directed away from the photodiode and scattered through the smoke chamber in a controlled pattern. The smoke chamber is designed to manage light dissipation and extraneous reflections from dust particles or other non -smoke, airborne contaminants in such a way as to maintain stable, consistent detector operation. When smoke enters the detector chamber, light emitted from the IRLED is scattered by the smoke particles, and is received by the photodiode. Model FDOT421 also utilizes a modern, accurate and shock -resistant thermistor to sense temperature changes. The signal processing with detection algorithms OWL allows the detector to first gather smoke and thermal data, and then analyze this information in the detector's neural network.' By comparing data received with the common characteristics of fires or fire signatures, Model FDOT421 can compare these signals to those of deceptive phenomena that cause other detectors to trigger a false alarm. Multi -criteria Fire Detector Each Model FDOT421 detector provides three (3) pre-programmed parameter sets that can be selected by the FRCP. LISTED APPROVED Siemens Data Sheet 6150 Smart Infrastructure - Building Products usa.siemens.com/fire 1. Labyrinth 2. Optical transmitter 3. Optical receiver 4. Heat sensor 1. Dustcover 2. Multi -criteria detector NOTE: Each detector consists of a dust -resistant photoelectric chamber, a solid state, non - mechanical thermal sensor, and microprocessor -based electronics with a low -profile plastic housing. Every Model FDOT421 fire detector is shipped with a protective dust cover. 1 !Ave '0 Model FDOT421 provides two (2) different alarm sources that can be selected individually (ON or OFF) by the control panel. Alarm Source 1 (Neural Network) — Combines smoke (heat) with the following field -selectable profiles: • Standard • Duct Standard: This parameter set, which is practically ideal for normal office, hotel -lobby -type applications, is the default setting. This parameter set additional offers improved resistance to false alarms in areas where misleading deceptive sources and helps reduce cooking nuisance alarms (UL 268 7th Ed. Listed) Duct: When using this detector direct in air duct applications, be sure the detector is set to the parameter "Duct". Alarm Source 2 (Thermistor) — Heat only; provides the following: • Static I fixed at 135°F (57°C), default setting • Rate -of -Rise detection at 15°F I min. (8.3°C I min.) If the detector is not programmed, Model FDOT421 will default to a 'standard' profile setting, which allows operation for a normal office -type environment. Model FDOT421 contains a tri-color LED indicator, capable of flashing any one (1) of three (3) distinct colors: GREEN I ... I RED. During each flash interval, the microprocessor -based detector monitors the following fire -system conditions: • Smoke in its sensing chamber • Smoke sensitivity is within the range indicated on the nameplate label • Internal sensors and electronics Based on the results of the monitoring, the LED indicator flashes the following: FLASH COLOR CONDITION FLASH INTERVAL [in seconds] GREEN*: Normal supervisory operation. 10 Smoke sensitivity is within rated limits. YELLOW: Detector is in trouble and needs replacement. 4 ' Alarm' condition 1 NO FLASH: Detector is not powered. — * denotes LED can be turned OFF Please follow the corresponding description of the panel used. A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed information is required, a printed report can be provided from the respective Desigo Fire Safety Modular I Model FC20-series I FireFinder XLSIV FACPs that indicates the status and settings assigned to each detector. Siemens Smart Infrastructure - Building Products —2— usa.siemens.comlfire All Model FDOT421 detectors use a surface -mounting base I Model DB2-HR I DB-11 or Model DB-11 E. Each base mounts onto a 4-inch (10.2 cm.) octagonal, square or single -gang electrical box. The base utilizes screw -clamp contacts for electrical connections and self -wiping contacts for increased reliability. The Model DB-11 detector base can be used with the optional Siemens Model LK-11 detector locking kit, which contains 50 detector locks and an installation tool to prevent unauthorized removal of the detector head. Model DB-11 has aesthetically conducive plugs to cover the outer mounting -screw holes. Model FDOT421 may be installed on the same initiating circuit with the following [when used with Desigo Fire Safety Modular Model FC20-series I FireFinder XLSIV FACPs1 - • XTRI Series interface modules • HTRI series interface modules • HMS & XMS series manual stations HFP-11, HFPT-11 detection devices HCP output control modules HZM conventional zone module Each detector is shipped with a protective dust cover, consists of the following: • Built-in ISOtechnology for True-Class-X SLC performance • Dust -resistant photoelectric chamber • Solid State, non -mechanical thermal sensor • Microprocessor -based electronics with a low -profile plastic housing All Model FDOT421 detectors are approved for operation within the UL-specified temperature range of 320F to 100°F (0 - 38°C). Installation of Model FDOT421 intelligent, addressable multi -criteria detectors requires a two -wire circuit. In many retrofit cases, existing wiring may be used. 7-tapping' is permitted only for Style 4 (Class B) wiring. Model FDOT421 is polarity insensitive, which can greatly reduce installation and debugging times. When operating in NFPA 72 Class-X applications SLC polarity must be maintained to support up to 252 isolation ready devices per loop. When used in mixed mode a maximum of 30 non -isolated devices between isolation devices (wired in polarity - insensitive mode). See control panel install document for further details. Model FDOT421 can be applied within the maximum 50-feet (15.24 m.) center spacing (2,500 sq. ft. [232.2 sq. m.1) per Underwriters' Laboratories. This application guide is based on ideal conditions, specifically, smooth -ceiling surfaces, minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not mount detectors near to heating I ventilation I air-conditioning (HVAC) outlets. Exposed joists or beamed ceilings may also affect safe spacing limitations for detectors. Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire -protection system engineering and common sense dictate how and when fire detectors are installed and used. Contact your local Siemens - Fire Safety distributor or sales office whenever you need assistance applying Model FDOT421 in unusual applications. Be sure to follow NFPA guidelines and UL Listed 1 ULC Listed installation instructions - included with every Siemens - Fire Safety detector - and local codes for all fire -protection equipment. Model FDOT421 is a plug-in, (2) two -wire Photoelectric I Thermal (heat) detector, compatible with Model FC20-series Desigo Fire Safety Modular Model FC20-series I FireFinder XLSIV FACPs. Each Model FDOT421 detector has microcomputer -chip technology and highly stable, solid-state electronic circuitry. Model FDOT421 detectors utilize a modern, accurate and shock -resistant thermistor to sense temperature changes. This electronic -sensing method virtually eliminates thermal lag associated with mechanical temperature -sensing devices, and provides almost instantaneous temperature status to the FACP. Model FDOT421 provides seven (7) field -selectable, pre-programmed temperature settings: • Fixed 1357 (57°C) • Rate -of -Rise: 1571 min. (8.3°C) This feature is compatible with Model FC20-series Desigo Fire Safety Modular Model FC20-series I FireFinder XLSIV systems, as well as with FC I FV2025 or FC I FV2050 FACPs. Siemens Smart Infrastructure - Building Products -3- usa.siemens.comlfire Model FDOT421 is compatible with the Siemens field -device programmer / test unit (Model DPU), which is a compact, portable and menu -driven accessory for electronically programming and testing these addressable detectors promptly and reliably. For instance, the field technician selects the accessory's program mode, and enters the desired address. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods (e.g. - dials and rotary switches), and reduces installation and service costs by electronically programming and testing the detector prior to installation. When set in test' mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the detector is operating properly. Each field -device programmer / test unit operates on AC power or rechargeable batteries, providing flexibility and convenience in the programming / testing of fire -safety equipment from practically any location. Additionally, with the use of a Model DPU unit, there is no longer a cause for concern with any vibration, corrosion and other deteriorating conditions that can accompany the vitality of a mechanical -addressing mechanism. The encompassing result is an intelligent detector that provides enhanced detection capability to a wide range of products of combustion - while offering unsurpassed rejection to nuisance -alarm sources, including: dust I steam I aerosols and other deceptive phenomena that could cause false alarms. Technical Data OPERATING *32° -'1007 TEMPERATURE: (0° -18°C) RELATIVE 0 - 95% HUMIDITY: (non -condensing) AIR PRESSURE: No effect INPUT VOLTAGE 16VDC - 30VDC RANGE: ALARM, 410pA CURRENT, MAX.: 'STANDBY, 250pA CURRENT, MAX.: MAXIMUM 30-ft. (9.144 m.) centers SPACING: (900 sq. ft. 183.6 sq. m.), per NFPA 72 and ULC-S524 • Fixed 135°F (57°C) THERMAL • Rate -of -Rise: RATING: 15°F / min. (8.3°C) at fixed 135°F (57°C) DETECTOR 0.317 Lbs. (0.144 kg.) WEIGHT: MECHANICAL UL Listed / ULC Listed PROTECTION with STI Guard Model GUARD: STI-9604 • UL268 3.52-4.17% / ft obs. SENSITIVITY ULC 3.52-4.27% / ft obs. RANGE: UL268A 2.32-2.84% / ft obs. (direct in -duct) Panel Compatibilities MODEL DATA OR TYPE SHEET PANEL XLS 6300 FireFindeO (fire -only overview) XLSV 6340 FireFinder (fire w/ voice) Desigo 7300 Desigo Modular Modular (system overview) FC901 5813 Desigo Fire Safety 50-point addressable FC2025 Desigo Fire Safety 252-pt. addressable (fire) 6815 FC2050 Desigo Fire Safety 504-pt. addressable (fire) Desigo Fire Safety 252-point addressable FV2025 (fire w/ Intelligent Voice Communication [IVC]) 6821 504-pt. addressable FV2050 (fire w/ Intelligent Voice Communication [IVC]) Details for Ordering MODEL PART OR TYPE NUMBER PRODUCT Addressable FDOT421 554320-F6-A1 Multi -Criteria Fire Detector Compatible Devices: MODEL PART OR TYPE NUMBER PRODUCT Sounder base with ABHW 4B S54320 F13 Al Loop-PowerOption Sounder base for ABHW 4S 554320 F14 Al Sleeping Areas ADB BOX 500 698360 Surface Mount Adapter Box for Audible Base Relay base compatible DB2 HR S54370 F12 Al with Siemens standard and advanced detectors Detector Mounting Base DB 1 1 500 094151 (for Series 11) DB 1 1 E 500 094151E Detector Base (small) Remote Alarm RL-HW 500 033310 Indicator: Single -gang -box mount, red Remote Alarm RL-HC 500 033230 Indicator: 4" (10.2 cm.) octagon - box mount, red LK 1 1 F500-695350 Base Locking Kit (for Series 11) See: www.STI-USA.com for further details on ordering Model STI-9604 In Canada order: MODEL PART PRODUCT OR TYPE NUMBER Detector DB-1 1 C 500-095687 Mounting Base, ULC Listed Siemens Smart Infrastructure - Building Products —4— usa.siemens.com/fire NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. iMENS THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING SIEMENS ❑ Each detector base supports Isolation The detector bases are low -profile, surface mounting bases used with various field wiring for ISOtechnology feature Siemens — Fire Safety conventional and addressable detectors. Model DB2-HR, which is a redesign of Model DB-HR, is compatible with the standard, addressable type of ❑ All bases compatible with optional intelligent detectors, as well as the multi -criteria detection devices utilizing the Model LK-11 detector -locking kit patented ASAtechnoloyfm ❑ Each detector base also functions with Model DB2-HR supports operation with Siemens' 50-point addressable; 252-point the addressable Models FD0421, addressable; 504-point addressable, and FireFinder® XLS I Modular fire systems. A FDOT421, FDOOT441, FDOOTC441 and relay output from the fire detector base for signaling other devices is provided by FDT421 intelligent detectors Model D132-HR. ❑ Model DB2-HR is compatible with The detector bases use screw -clamp contacts for electrical connections and self- ASAtechnology multi -criteria detectors wiping contacts for increased reliability. Further, the bases can be used with the optional Model LK-11 detector locking kit, which contains 50 detector locks and an ❑ Each detector base is compatible with installation tool, to prevent unauthorized removal of the detector head. Model'H', "l1"and "121"series of conventional detectors ❑ Model DB2-HR has backwards Models DB-11 and DB-11 E are standard bases for Model 'H'-series 11" and Model compatibility with SiemensModel'H'- "121"-series conventional detectors. Model DB-11 has a 6" (15.2 cm) diameter, and series intelligent detectors the diameter for Model DB-11 E is 4.5 inches (11.4 cm). ❑ Models D13-11 and D13-11 E mount on a Moreover, Models DB-11 and DB-11 E mount on a 4"-square, (10.2 cm) octagon or 4-inch octagon, square or single gang electrical box single -gang box. Model DB-11 has integral, decorative plugs to cover the outer screw holes. ❑ Model D13-11 has plugs to cover the However, Model DB2-HR mounts on a double -gang, 4-inch (10.2 cm.) square outer -mounting screw holes electrical box. ❑ Model DB2-HR mounts on a 4"-square, double -gang electrical box ❑ UL268 Listed, ULC-S529 Listed ❑ FM, CSFM and NYC Fire Department Approved a � �IkTA F. AW mow FMO' APPROVED Siemens Data Sheet 6161 Smart Infrastructure — Building Products usa.siemens.comlfire I r-----6"(11.4cm.)Diameter I 1/2" i1 27 c m 1 1171ry E ` I r4V I I I� J Diameter I----r"" I L_ 2-3/4"(7cm.)--J I _ L--- 4-1/8' (te.s cm.]Diemeter---J ee- � Note: The Model D13-11 E base detector has a diameter dimension of 4.5" (11.4 cm). Wiring Diagrams moic%ie OlMq ro 1b �rzQoaaa.eT.ucmra�o�rcTw a e e s s cwTION I. Do nerux aop.e carte antler bex arminel S. BreeY wln °a9m�'.'�'°`•"`0^m^°°^'^M t. erwiY e�.rYsan of connscrion. ��1 3. YAr e�rowYe Yeaetl to convole crnicslsylem bsY4MISYr�1 u ma�nM eHecbrmtl ope.n.l r1�lYle�IMbOLLY e..ka M M rorowM ucw. Note: The illustration above is typical wiring for Models D13-11 and D13-11 E (using Models 01-1121, OP121, and Hll21 detectors). LINE1• TONEXTBASE DO NOT USEAN END OF LINE DEVICE DETECTOR BASE MODEL D&11/DB-11E FROMADDRESSABLE 0 DEVICE CIRCUIT OF A 5 la 5 10 5 COMPATIBLE CONTROL OPTIONAL TB1 NCI RELAY CONTACTS UNITORPREVIOUS B 1b REMOTE ALARM B 1b ( } 3A, 120 VAC ADDRESSABLE DEVICE TB2 0 INDICATOR 0 i8 3A, 30 VDC MODELS TB3 8727W / B727C/ RL-HW / RL-HC UNE2' DO NOT USEAN END OF LINE DEVICE SUPERVISEDAND POWER LIMITED TO NEXT BASE Note: The illustration above is typical polarity insensitive wiring for Models D13-11 and D13-11 E (using Models FD0421 1 FDOOT441 I FDOOTC441 1 FDOT421 1 FDT421 detectors). UNE1 TO NEXT BlS; DONOTUSEM END OF UNE DEMCE DETECTOR BASE MODELDB-11/D&11E T,,',4n9�'d SIEMENSco bble contrd unit 5 to OPNOmL \ REMOTE TBI 5 1. B 1b J5+ /I NTACTS• RELAY VA e 1b PiM M INDICATOR T@ -- Je- lnc } A 3q WVOC MODELS 8727W I8727C1 B3 RL+M' I RL-HC UNE2 - - 0 DONOTUSEAN END OF UNE DEMCE TO NM BASE Note: The illustration above is typical isolator mode wiring for Models DB-11 and DB- 11 E (using Models FD0421 1 FDOOT441 1 FDOOTC441 I FDOT421 1 FDT421 detectors). vE a ua 1_ glerIIT�O � ~ rolemll�reaeo eeleeanrlEur eAer coos uaYw vur ova Mvl wsn ne1oG:0M. oro.rnATaao owwr se:Ye:NswureN. roc wNnen Yrora .L �''�' l ovnAcn TYE Aeur mNTKn ,aE�e�..o�rue w n� Tic. sL 1mvK )A ]o VfK e141 AeerT CaoTMI rorEn orvu L1~EI OOM011�E MIfIO 6 YlE 1te10 IIEI ~ NIA�OOueL7Og1�Ae MIRM�b01hw aEtTwrlr Wt 01 fMlDilF e� 0 M'Aa 07eN,�r01•t �+w • u�.uw.erawbanso..oM.n u.wiva,rnw Note: The illustration above is typical wiring for Model D132-HR for polarity - insensitive detectors. Siemens Smart Infrastructure — Building Products -2_ usa.siemens.comlfire MODEL PART OR TYPE NUMBER PRODUCT DB-11 500-094151 Low -Profile Surface -Mount Base DB-11 C 500-095687 Low Profile Surface -Mount Base [Canada] DB-11 E 500-094151 E Smaller -Diameter Detector Base DB-HR 500-033220 Relay Base for'H'-Series Intelligent Detector Relay base compatible with standard and advanced DB2-HR S54370-F12-A1 detectors; backwards compatible with Model 'H'-series intelligent detectors FDT421 S54320 F5-Al Thermal (Heat) Detector FDOT421 S54320-F6-A1 Addressable Multi -Criteria Fire Detector FDO421 S54320-F4-A1 Photoelectric Smoke Detector FDOOT441 S54320-F7-A1 Multi -Criteria Fire Detector with ASAtechnologyTm FDOOTC441 S54320-F8-A1 Multi -Criteria Fire / CO Detector with ASAtechnologyTM LK-11 500-695350 Base Locking Kit for Model "IV -series detectors H1121 S54372-F3-A1 Heat Detector OH121 S54372-F2-A1 Multi -Sensor Smoke Detector OP121 S54372-Fl-Al Photoelectric Smoke Detector NOTICE— The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets —as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING SIEMENS ❑ Durable metal design The Siemens intelligent manual fire -alarm boxes (Models HMS-S I HMS-SZ and ❑ Shock and vibration resistant HMS-D I HMS-DZ) provide the most advanced method of address programming and supervision. ❑ Single-action (Model HMS-S I -SZ) and Each Model HMS -series manual box achieves the state of an 'intelligent -initiating double -action (Model HMS-D I -DZ) device' by incorporating custom microcomputer -chip technology with sophisticated, stations bi-directional communication capabilities with the panel, which include Siemens ❑ Pull -down lever is down, until Modular, as well as Siemens 50-point, 252-point and 504-point addressable FACPs. manually reset The Model HMS- series manual fire -alarm boxes are also included in US Coast Guard • Reset with Allen Key (USCG) approval for use in marine and other harsh environments, when used with • No break rods necessary the Siemens 252-point and 504-point USCG approved addressable system. ❑ Custom microcomputer -chip technology ❑ Polarity insensitive via SureWireTM technology ❑ Dynamic supervision to the fire -alarm control panel (FACP) • Device Programmer Unit (Model DPU) programs and verifies address and tests functionality of each device ❑ Electronic -address programming (EEPROM) is easier, as well as more efficient, dependable ❑ Surface or semi -flush installation ❑ Two -wire ❑ Americans with Disabilities Act (ADA) Compliant ❑ UL Listed ❑ USCG (161.00216010), ❑ FM (#3015946 & 3052621), CSFM (#7150-0067:0036) ❑ NYC Fire Dept. (#202-12E, Vol. 1) Approved Models HMS-S I HMS-SZ and HMS-D I HMS-DZ are constructed of durable, molded polycarbonate material that is matte finished in red with raised white lettering. The housing accommodates a 'pull -down' lever, which — when operated — locks into position; indicating the fire - alarm box has been activated. The pull -down lever remains down 1 in the 'locked' position, until the fire -alarm box is manually reset. The manual fire alarm box can only be reset by opening the hinged housing cover with an Allen key; followed by closing and locking the cover. Models HMS-S I -SZ and HMS-D I -DZ operate with Siemens — Fire Safety FACPs. The microcomputer chip to the manual fire -alarm box has the capacity of storing — in memory — identification and important operating -status data. Models HMS-S I -SZ and HMS-D I -DZ are fitted with screw terminals for connection to an addressable circuit, and can be either surface or semi -flush mounted. The Model HMS -series manual fire -alarm boxes derive their power, communicate information and receive commands over a single pair of wires. Each box is compatible on the same circuit with all Model W-series detectors, interfaces or addressable, conventional zone modules. U` a ® APPROVFMED �® 9 1 iu— ni is 1 Dual -Action Station Model HMS-S I -SZ Single -Action Station Siemens Data Sheet 6306 Smart Infrastructure - Building Products usa.siemens.comlfire Mounting Diagram Innovative technology from Siemens — Fire Safety also allows all Model HMS -series intelligent manual fire -alarm boxes to be programmed via the Device Programmer I Test Unit (Model DPU). The programmer 1 tester is a compact, portable and menu - driven accessory that makes programming and testing of a manual fire -alarm box device faster, easier and more dependable than previous methods. Model DPU eliminates the need for mechanical -addressing mechanisms of a device because Model DPU electronically sets the address of the manual fire -alarm box into its microcomputer chip, non-volatile memory. Therefore, vibration, corrosion and other conditions -- which can compromise the functionality of mechanical -addressing mechanisms — are no longer an issue. ELECTRICAL Current Draw 0.9mA (Active or Standby) INDOOR I DRY CONDITIONS Operating 32' — 100°F Temperature Range (0° — 38°C) Operating 0 — 93%, Humidity Range non -condensing + denotes Country Of Origin Siemens Smart Infrastructure — Building Products —2_ usa.siemens.comlfire NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets — as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product. All are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING SIEMENS .- • •. ❑ Intelligent device for use with various Model HCP I -Z from Siemens — Fire Safety is an intelligent control point device Siemens — Fire Safety fire -alarm designed for use with Siemens — Fire's NAC series of alarm signaling devices. control panels (FACPs) Additionally, various Siemens — Fire Safety FACPs, which include Siemens Modular as well as the 50-point, 252-point and 504-point addressable FACPs can recognize ❑ Used as a telephone zone, speaker Model HCP devices. zone or notification appliance circuit (NAC) Model HCP I -Z can be configured as an independent, remotely located telephone zone, speaker zone or NAC. Model HCP I -Z is programmed and tested using the • Provides NACs when used Device Programming I Test Unit (Model DPU), which eliminates the need for with a Siemmensess FACP mechanical -addressing mechanisms (i.e. — program jumpers, DIP switches or rotary • Used as a NAC under the Siemens - dials). Fire Safety NAC product line Model HCP is supervised for loss of 24 VDC input power, as well as short -or -open • Provides either a 25V (35 Watts) or 70.7V (25 Watts) single -channel output -zone wiring. Model HCP I -Z mounts in a standard double -gang or 4" (10.2 speaker zone (only used with cm.) square electrical box. Siemens Modular and FireFinder When Model HCP I -Z is programmed as a speaker zone, the high -power audio risers XLS) are supervised using the Model ZAC-40 zone amplifiers. Programmed as a telephone • Provides firefighters' telephone zone, the telephone riser is supervised by the (8) Eight -Zone Telephone Card (Model circuit (only used with Siemens TZC-8B). Modular and FireFinder XLS FACPs) Specifications ❑ Polarity insensitive with SureWiret Model HCP I -Z communicates through the analog loop of Models XDLC for Modular technology systems (Model DLC for FireFinder). Each control -point device can be wired in either ❑ Mounts on standard electrical box Class A (Style Z) or Class B (Style Y). The 24 VDC power input comes from either the FACP or from any UL Listed power -limited, auxiliary power supply. • 4" (10.2 cm.) square or double gang ❑ No mechanical -address programming required ❑ Includes a dial -tone generator for telephone use ❑ Supervised input and output power ❑ UL Listed, ULC Listed ❑ CSFM and NYC Fire Dept. Approved For Siemens Modular I FireFinder XLS systems, compatible power supplies for the intelligent control point device are: ■ Model PSC-12 power supply ■ Model PSX-12 power -supply extender ■ Models PAD-3, PAD-4 NAC extenders, or • Any power -limited, 24 VDC power supply that is UL Listed for fire - protective -signaling use For the Siemens 50-point, 252-point and 504-point addressable fire systems, compatible power supplies include: ■ Siemens NAC circuits ■ PAD-3 or PAD-4 NAC Extenders ■ Any power -limited, 24 VDC power supply that is UL Listed for fire - protective -signaling use Intelligent Control Point Device Siemens Smart Infrastructure - Building Products Data Sheet 6311 usa.siemens.com/fire 1 Siemens Modular, 252- and 504-point systems support up to 60 Model HCP I -Z devices per SLC. Siemens 50- point, addressable fire system supports a maximum of 50 addressable devices of all types. NOTE: The maximum NAC load that may be connected from Model HCP I -Z into a 50-point, 252-point or 504-point fire system is 1.50 Amps at 24VDC. The H-series intelligent control point device is UL 864 Listed for indoor dry locations within a temperature range of 120 +/- 3°F (49 +/- 2°C) to 32 +/- 3°F (0+/-2°C) and a relative -humidity range of 93 +/- 2% at a temperature of 90 +/- 3°F (32 +/- 2°C). Use a standard 3-112" (8.9 cm.) deep, double -gang electrical switchbox or a 4" (10.2 cm.) square electrical box that is 2-1/8". (5.4 cm.) deep with either a 1.5" (3.8cm.) deep extension or a 1.25" (3.2cm.) deep plaster -ring extension. 2. Connect the field wiring. Insert Model HCP into the box and fasten the device plate to the box. 3. Cover the device front plate with the 5" (12.7 cm.) switchplate (supplied) and fasten with two (2) plate screws. Mounting Diagram Electrical Current Draw (Active or Standby) 1.OmA + denotes Country of Origin 4-INCH SQUARE BOX DOUBLE GANG BOX 2 1/84NCHES DEEP 3 1/2414CHES DEEP ` O O 0 -- -- O ® HCP 0 HCP O O 0® O O 0® S WITCHPLATE SWITCH PLATE 54NCHES SQUARE SINCHES SQUARE (SUPPLIED) (SUPPLIED) NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. iyi4MCIP1 ❑ Siemens ISOtechnologyTM Provides "True Class-X" operation meeting NFPA 72 SLC field wiring requirements Supports 252 ISOtechnology ready devices per loop, and in mixed mode up to 30 devices between isolated devices ❑ Dual input on Model XTRI-D, via a single address ❑ Integral single -pole, double -throw (SPDT) relay on Model XTRI-R: - Up to 4 Amps. ❑ Low current draw ❑ Polarity insensitive (in non -isolation mode) via SureWireTM technology: - Modern technology supports comprehensive system and interface communication ❑ Multi -color light -emitting diode (LED) indicates system status: GREEN I AMBER I RED ❑ Mounts in a 4-inch (10.2 cm.) square, 2- 1/4" (5.7 cm.) deep single -gang or double - gang back box ❑ Non -obstructive front-end access to programming port and wiring terminals SIEMENS The Siemens - Fire Safety XTRI-series Intelligent Interface Modules are designed to provide the means of interfacing direct shorting devices to the fire -alarm control panel (FRCP) SLC. All modules take up one (1) address on the loop. Each XTRI-series interface module provides the "built-in" ISOtechnology feature - intelligent dual isolation meeting NFPA 72 Class X (Style 7) wiring requirements. Up to 252 isolators per loop and up to 30 devices between isolators (wired in polarity -insensitive mode). Additionally, the devices between isolators can either be'H'-series or the more contemporary' X'-series detection devices. The Siemens - Fire Safety XTRI-series Intelligent Interface Modules are available in three (3) individual types: > One (1) Dual -Input: XTRI-D > Two (2) Single -Inputs: XTRI-R (with relay) I XTRI-S - The single -input versions are each designed to monitor a normally open (N.0) or (N.C) normally closed dry contact XTRI-D I XTRI-R I XTRI-S incorporates ISOtechnology - the configurable, built-in dual isolator function. Additionally, an XTRI-series interface module supports NFPA 72 Class X (Style 7) survivability requirements for shorts while providing reliable alarm communication to the Siemens FACP. The isolation feature found on the XTRI-series Intelligent Interface Modules gives information as to the location of the fault. When a short occurs, the panel can identify the fault automatically, and the module recognizes the short location (in front of the device or behind the device). Overall, the built-in isolators improve the diagnostics and location of the problem, including a short. The modules are configurable by a Siemens compatible FACP (or panels) in an isolator (polarity sensitive) or non -isolator (polarity insensitive) mode. When a XTRI-series interface module is configured as an isolator, that module has the capacity of functioning as both an in/out device, as well as an isolator. Smart Infrastructure -Building Products usa.siemens.comlfire - 1. 4" (10.2 cm.) -;� square box I r cm.) back box f, 7: -_; 2. 3.5" (8.9 cm.) 30 double -gang back box i 3. 5" (12.7 cm.) square switch plate, supplied) Intelligent Device Interface Module Model XTRI-R PROGRAMINGNOLES Through the use of an addressable 'Form C relay, the Model - XTRI-R relay and contact device input are controlled at the same address. The relay and input contact can be controlled as a separate function from a Siemens compatible FRCP. The relay is typically used where control or shunting of external equipment is required. SLOTFOR LOCATING TAB 6' Model XTRI-D Model XTRI-D is a dual -input module that is designed to MI supervise and monitor two (2) sets of dry contacts. Model cTNm — XTRI-D only requires one (1) address, but responds DESIGN FOR DPUXVCONNE�.. independently to each input. Model XTRI-D is ideal for ISALLO EDN R THE PLUG p Y P IS ALLOWED TO THE DPU monitoring a water -flow switch and its respective valve INSERT THE PLUG PROGRAMMER tamper switch. AT EITHER DIRECTION TESTER NOTES: Each interface module mounts directly to a user -supplied switchbox. The electrical boxes, seen above, are supplied -by -others (130). Models XTRI-D, XTRI-R and XTRI- S mount directly onto a 4-inch (10.2 cm.) square, 2'/4" (5.7 cm.) - deep box back box, or to a user - supplied double -gang 3'/z" deep back box. A 5" (12.7 cm.) square, off-white faceplate is included in each shipment of a Siemens Model XTRI-series module. Field -Device Programmer / Test Unit Siemens - Fire Safety innovative technology allows Model XTRI-series intelligent interface modules to be programmed via the Siemens field -device programmer / test unit (Model DPU), which is a compact, portable and menu -driven accessory for electronically programming and testing Siemens peripheral modules and devices promptly and reliably. For instance, the field technician selects the accessory's program mode, and enters the desired address. Model XTRI-series interface module is connected to Model DPU with the programming cable provided with the tester. NOTE: Since the XTRI-series of interface modules are advanced initiating devices, the latest Model DPU firmware update is required. Model DPU eliminates the need for cumbersome, unreliable mechanical programming methods (e.g. - dials and rotary switches), and reduces installation and service costs by electronically programming and testing the module prior to installation. When set in test' mode, Model DPU will perform a series of diagnostic tests without altering the address or other stored data, allowing technicians to determine if the module is operating properly. Each field -device programmer I test unit operates on AC power or rechargeable batteries, providing flexibility and convenience in the programming I testing of fire -safety equipment from practically any location. Additionally, with the use of a Model DPU unit, there is no longer a cause for concern with any vibration, corrosion and other deteriorating conditions that could negatively affect any electro-mechanical-addressing mechanism. Siemens 'X' modules may be used along with Model 'H'-series intelligent detectors; Model 'HMS' -series addressable manual stations, or any other 'H'-series addressable intelligent module (e.g. Model HZM or Model HCP). Additionally, the X-series modules are compatible with all Desigo and Cerberus Pro detectors and peripherals of the same circuit. Interspersing 'X' & 'H'-series devices on the same loop is mostly permitted, but there are exceptions: Models HLIM (isolation module) and SBGA-34 (audible base) cannot be used with 'X' devices on the same loop. Siemens Smart Infrastructure - Building Products -2- usa.siemens.com/fire Models XTRI-D I XTRI-R I XTRI-S intelligent interface modules are UL Listed I ULC Listed. Environmental operating conditions for each interface module is 327 (0°C) to 120°F (49'Q with a relative humidity of no greater than 95%, non -condensing. LED lindicators FLASH FLASH COLOR CONDITION INTERVALS [in seconds] GREEN*: Normal supervisory operation 10 YELLOW: Device is in trouble and needs to be replaced 4 Locate I 'Alarm' 1 Output Device (XTRI-R only) 10 Power is not being received t NO FLASH: Replacement is needed IF - M -echnical Data OPERATING VOLTAGE RANGE: 13VDC - 32VDC RELATIVE HUMIDITY: 0 - 95% (non -condensing) 'ACTIVE' OR'STANDBY' CURRENT, MAX.: 500pA LINE SIZES AMERICAN WIRE GAUGE (AWG) 14 AWG, max. 18 AWG, min. CURRENT DRAW MAX IAVG. XTRI-S 650pA XTRI-R 750pA XTRI-D 950pA RELAY RATINGS: (for Model XTRI-R) RESISTIVE: 4 Amps 125 VAC 4 Amps 30 VDC INDUCTIVE: 3.5A, 120 VAC (0.6 pF) 3.OA, 30 VDC (0.6 pF) 2.OA, 120 VAC (0.4 pF) 2.OA, 120 VAC (0.35 pF) 2.OA, 30 VDC (0.35 pF) Details for Ordering MODEL PART PRODUCT OR TYPE NUMBER XTRI-S S54370-133-A1 Single Input Module XTRI-R S54370 B1 Al Single Input Module (with relay) XTRI-D S54370 B2 Al Dual Input Module DPU =500-033260Device Programmer / Test Unit NOTE: Refer to installation manual: PIN - A6V101055479 to ensure Model XTRI-D I XTRI-R XTRI-S compatibility with the Siemens FACPs intended for use in the given application. NOTICE- The information contained in this data -sheet document is intended only as a summary, and is subject to change without notice. The product(s) described here has/have a specific instruction sheet(s) that cover various technical, limitation and liability information. Copies of install -type, instruction sheets -as well as the General Product Warning and Limitations document, which also contains important data, are provided with the product, and are available from the Manufacturer. Data contained in the aforesaid type of documentation should be consulted with a fire -safety professional before specifying or using the product. Any further questions or assistance concerning particular problems that might arise, relative to the proper functioning of the equipment, please contact the Manufacturer. SIEMENS J THIS PAGE INTENTIONALLY LEFT BLANK FOR DUPLEX PRINTING POLDER % ���%SON/� PS-121000 12 Volt 100.0 AH Rechargeable Sealed Lead Acid Battery We've Got The Power.Tm • U: Universal terminals: Heavy-duty posts with 'nut & bolt' fasteners • T6: Threaded insert w. 6 mm stud fastener sealee rze�nareeaoie aa„e� MODEL PS-121000D � i oaoamv �" U: Positive U: Negative (Terminal 00 (Terminal 100 16II- oII- 3 N T6 H I� w a® T_ ®� a o � ea„ary o 0 0 o T PEA 50M/C. HT H I- L �I L: 12.00 (305) W: 6.60 (168) H: 8.15 (207) HT 8.98 (228) Tolerances are +/- 0.04 in. (+/- 1 mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. • Absorbent Glass Mat (AGM) technology for superior performance • Valve regulated, spill proof construction allows safe operation in any position • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover (UL94-HB) • Integrated ABS carrying handles for ease of movement • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 2O845 Nominal Voltage.......................................................12 volts (6 cells) Nominal Capacity 20-hr. (5A to 10.50 volts) .............................................. 100.0 AH 10-hr. (9.2A to 10.50 volts) ............................................. 92.0 AH 5-hr. (15.8A to 10.20 volts) ........................................... 79.0 AH 1-hr. (55.2A to 9.00 volts) ............................................. 55.2 AH 15-min. (175A to 9.00 volts)................................................43.8 AH Approximate Weight ..................................... 68.00 lbs. (30.84 kg) Energy Density (20-hr. rate) ............. 1.86 W-h/in3 (113.45 W-h/1) Specific Energy (20-hr. rate) ............ 17.65 W-h/lb (38.91 W-h/kg) Internal Resistance (approx.) ....................................... 5 milliohms Max Discharge Current (7 Min.) ............................. 300.0 amperes Max Short -Duration Discharge Current (10 Sec.) .. 750.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C) 1 Month................................................................................. 97% 3 Months................................................................................ 91 % 6 Months............................................................................... 83% Operating Temperature Range Charge.................................................4°F (-20°C) to 122°F (50°C) Discharge.............................................40°F (-40°C) to 140°F (60°C) Case.................................................................................. ABS Plastic Power -Sonic Chargers ........................................... PSC-121 OOOOA-C MODEL FINAL VOLTAGE WATTS PER CELL @ 250 C 5 MIN 10 MIN 15 MIN 20 MIN 30 MIN 45 MIN 60 MIN 1.75 550 395 312 267 207 152 128 PS-121000 1.70 586 413 324 277 212 155 129 1.67 605 421 330 283 215 158 130 Discharge Time vs. Discharge Current 20 15 10 d L 5 E H d 2 rn N — 1 30 E 10 5 \ Final Voltage 10.5V 10.2V 9.6V �\ 9.0V 40°( 20% 0°( 8.1 V 5.0 10 20 50 100 200 Discharge Current (A) 14.0 13.0 8.0 Discharge Characteristics on ! !1 \I 10 ki I II k 1 MUSEUM-, am M .. - SAFE 011101 ■011�011■-.11., 1.2 2.4 6 12 24 36 48 1 2 4 6 810 20 40 (104°F) (68°F) I= min I' h I (32°F) Discharge Time Cycle Applications: Limit initial current to 20A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 1 A. Battery is fully charged under these conditions, and charger should be disconnected or switched to "float' voltage. "Float" or "Stand -By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self -discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. 100 O 80 C 0 dui 60 m y Z 40 CU m Shelf Life & Storage Charging is not necessary unles 100 % of capaciy is required. 5°C (41 °F) Charging before use is necessary to help recover full capacity. Charge may fail to restore full capacity. Do not 40°C 30°C 20°C (104°F) (86°F) (68°F) tetbatteeiesreac this state. U 0 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Power -Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for "C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers" and "Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Tel: +1-650-364-5001 Fax: +1-619-661-3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 Fax: + 1 -650-366-3662 nafional-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com internafionalwles@power-sonic.com CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: + 1 -619-661-2020 • Fax: +1-619-661-3650 0114 1M 9 2013. Power -Sonic Corporation. All rights reserved. All trademarks are the property of their respective o